Professional Documents
Culture Documents
Building Maintenance
Building Maintenance
a) Improper installation
The installation of roof will need a number of skilled workers. If the roof is not
installed properly, it wills yield to roof defect such as roof leakage and sagging.
The causes of roof defect arebecause the worker maybe not have a license, or
certificate apart from having a low level of experience.
b) Poor workmanships
c) Defective materials
Materials themselves also may be the factors to the roof defect. The material too,
may be not suitable to weather condition. Sometimes, it is not installed correctly
also due to sagging and deformation.
Flat roofs
Flat roofs are characterized by flat surfaces or roofing plans. This type of system
has a minimum slope, so as to allow drainage of rain- waters and to direct it
according to the water drainage plan. So, by flat roof one means the system that
has a slope ranging from -5º to 5º (NP EN 1991-1-4, 2010). Considering the
importance that the influence of a layer might have on the other ones in terms of
appropriate system performance, the main layers of a flat roof are summarized in
Table 1. In many cases, flat roofs include a levelling layer and a solidarization
layer.
The analysis of defects in flat roofs is a topic that was developed by different
authors as far as research is concerned. According to ROCHA (2008), the most
frequent defects occur in the common surface and in individual points, followed
by drainage systems. On the other hand, WALTER (2002) and CRUZ & AGUIAR
(2009) demonstrated that, out of the different defects that can be identified in a
flat roof and, especially, in the common area, the waterproofing layer
represented the most affected component (Table 3).
Table 3 Main defects in a flat roof system, adapted from PIRLA et al. (1999),
WALTER (2002), ROCHA (2008) and ARAÚJO et al. (2008)
Flat roof system
Common area
Cracking of waterproofing or Detachment of the Accumulation of surface
protection layer waterproofing or heavy dirt, debris and parasitic
protection vegetation / biological
colonization
Perforation of Blistering of waterproofing Waterproofing detachment
waterproofing
Accumulation of water Formation of pleats or Efflorescences in the heavy
stains and corrosion corrugations in the protection layer
waterproofing
Drainage system
Cracking Gutters rupture Corrosion and water stains
Perforations Lack of inlet drains and Surface dirt, accumulation of
downpipes debris, parasitic vegetation /
biological colonization
The effective functioning of a pitched roof, similar to any other element in the
outside envelope of the building essentially depends on the level of design and
detail, on the quality of the materials, on the execution of the system and on its
subsequent maintenance and use. As is the case in flat roofs, the importance of
individual points in pitched roofs is well known for the occurrence of irregular
situations. According to ROCHA (2008), the most frequent defects occur in
individual points, followed by common area and drainage system (Table 4).
Table 4 Main defects in the system of pitched roofs, adapted from PIRLA et al.
(1999), GARRAND (2001), ROCHA (2008) and LOPES (2009)
Common area
Defects in the ventilation Misalignment of cladding Loosening of cladding elements
system and in the fixation elements
elements
Surface dirt, accumulation of Differences in colour tones Peeling / disintegration
debris and parasitic
vegetation / biological
colonization
Cracking / fractures Corrosion Marked deformation of the
cladding
Individual points
Detachment of tail-ends Fluidity of the tail-ends Cracking / fractures
Surface dirt, accumulation of Blistering Peeling / disintegration
debris and parasitic
vegetation / biological
colonization
Corrosion Perforations Loss of watertightness
Drainage system
Cracking Gutters breakage Corrosion and water stains
Perforations Lack of inlet drains and Surface dirt, accumulation of
downspipes debris, parasitic vegetation /
biological colonization
Application methodology
In order to propose an inspection and maintenance plan for roof systems, one
needs to include all aspects that are relevant to an efficient management of
resources and costs. In fact, it is necessary to define various technical documents,
such as the building’s identification sheet, the inspection sheet of each
maintenance source element (MSE) and the scheduling of corresponding
proactive maintenance activities.
The definition of intervention priorities, depending on the type of defect and
related causes, is a process that must be integrated into the inspection and roof
maintenance plan, as it allows a reduction of the costs of the entire maintenance
system. Responding adequately to the needs, the definition of intervention
priorities can also avoid dangerous situations. The planning of proactive
maintenance actions for the different roof components includes predictive
(inspections) and preventive actions (cleaning, light interventions, deep
interventions and replacement) and their scheduling, keeping into account the
different service lives and materials that are applied.
The building’s identification sheet is a crucial document for any inspection action.
The document in question shows the name / location of the building, the year of
construction, its function (commercial, housing, service or other) and the number
of floors. The contacts made for the execution of the inspection, the existence of
previous interventions and the identification of maintenance source elements, as
well as their materials, are also crucial pieces of information that are to be
included in the above mentioned sheets.
In terms of maintenance, a building and its elements are considered as a set of
systems with specific maintenance needs, designated as maintenance source
elements (MSE). Each element is characterized by a different deterioration
mechanism and performance levels, and is usually independent from all other
elements.
According to BRAND (1994), a building can be divided into six layers that are
structured starting from the building’s envelope in contact with the outside, until
the inside (structure, surrounding “skin”, services, interior space and furniture).
Considering all the documents analysed, a proposal for classification of the
existing MSE in a roofing system was developed (Table 5).
Pitched roofs
Cladding Drainage system
Supporting structure Elements of anchorage and
metalwork
Ventilation system Roof skylights and windows
Tail-ends system Masonry elements
Flat roofs
Supporting structure Drainage system
Waterproofing layer Elements of anchorage and
metalwork
Protection layer Masonry elements
Tail-ends system
Inspection sheets
The scaling indicator for each defect and MSE was determined based on the
formula developed in the multicriteria analysis by FLORES-COLEN & BRITO (2006)
and MADUREIRA (2011), keeping into account the weight of each defect with the
worst scenario (maximum levels in each criterion adopted).
Proactive actions are applied to existing buildings and new ones alike. When
planning maintenance interventions, one must distinguish all different operations
that are necessary, such as inspection, protection treatments, repairs,
replacements or localized replacements, repairs in specific areas or full
replacement, at the end of the service life.
2. Foot traffic on steep roofs should be minimized both for safety reasons and to
avoid physical damage.
6. Install zinc strips to prevent moss build-up. Power washing the roof removes
moss and other debris but may erode granules on asphalt shingles, and may also
promote premature degradation of cedar roofing.
7. If asphalt shingle tabs are loose, re-tab with a cement recommended by the
shingle manufacturer.
1. Ensure ventilation is available, year round. Areas with louvers, ridge vents,
roof vents, and soffit vents need to be kept clear and never blocked off.
Adequate ventilation ensures heat and moisture do not build up in the attic
area. Adequate ventilation also prevents water from accumulating at the
bottom of the roof and then freezing (ice damming).
2. Zinc or copper strips nailed at the ridge cap can be effective to control
moss. Reaction between rain and the zinc or copper forms a mild solution
that is carried down sections of the roof. The optional use of these strips
can be eliminated if you are using preservative treated cedar.
3. Overhanging branches should be kept trimmed away from the roof. This
will prevent leaves, small branches and other debris from building up and
keeping the roof wet.
5. Do not allow leaves, branches or other debris to build up on the roof. Both
surface areas and keyways (spaces between shakes and shingles) need to
be kept clear. Cedar needs to breathe, and therefore needs to be kept
clean.
Conclusions
Considering the scope of the dissertation, it was carried out a thorough research
in order to standardize three key documents for the implementation of inspection
and maintenance plan for roofs: identification and characterization sheet of roofs;
sheet inspection and planning proactive actions.
During the study conducted the existence of a large variety of constructive types
and materials in roofs (pitched and flat) was observed. The appropriate choice of
type to be applied is quite arbitrary, since each one of them has advantages and
disadvantages, but it was possible to illustrate their main functionalities. The
deterioration of a roof’s elements is an issue that is still under development by
researchers. However, it was observed that the defects that occur in roofs
represent quite a high percentage when compared to the total number of defects
in a building.
The field work showed that roofs included in the coastal environment have higher
levels of degradation, particularly anchorage and metalwork elements, which
showed considerable corrosion rates. From the analysis, it was found that
cladding is the pitched roof element with more frequent anomalies, followed by
drainage system and tail-ends. Similarly, it was found that the waterproofing layer
is the flat roof element with more frequent anomalies.
For the type of anomaly, it was demonstrated that aesthetic defects, particularly
surface dirt, accumulation of debris and parasitic vegetation / biological
colonization, are most frequent in the elements analysed, explaining the fact that
they are the first manifestations of degradation , caused by lack of maintenance
by the users and entities responsible for the management of the building.
The field work showed that, in sporadic cases, maintenance actions need to be
anticipated or delayed compared to what was theoretically stipulated, especially
in pitched roofs. However, in flat roofs the frequency of maintenance actions
remained the same compared to theoretical planning.
In short, an effort was made to summarize the main factors underlying a proactive
approach to maintenance based on the following information:
ARAÚJO, A., BRITO, J. de and JÚLIO, E., “Inspection manual of outside pathology
of Portugal buildings in built in the period 1970 to 1995”, Report ICIST DTC 24/08,
IST, Lisbon, 2008, 194 p. (in Portuguese).
BRAND, S., “How buildings learn. What happens after they're built”. Penguin
Group, USA, 1994.
BRITO, J. de and PAULO, P., “Pitched roofs and cladding classification”, Building
construction technology leaves, IST. 2001, Lisbon, 78 p (in Portuguese).
KYLE, B. and KALINGER, P., “Service life prediction of roofing systems by reliability-
based analysis”, Fourth International Symposium of Roofing Technology,
Gaithersburg, 1997, pp. 50-57.