‫مختبر الخليج لمواد البناء‬

GULF LABORATORY
For Construction Materials
C.R. # 2051050843

EUROBLAST MIDDLE EAST REF# GCJ/Q/2522/23


P.O. BOX# 31230 DUBAI DATE : 24.12.2023
U.A.E.

ATTENTION: - MR. FARHAN KHURRAM


Procurement Department 0549287694

SUBJECT :- COST PROPOSAL FOR MATERIAL TESTING SERVICES AT


EUROBLAST ME IMI ZONE D2 FACILITY, RAS AL KHAIR S.A.

Dear Sir,

Thankyou very much for your E-mail request dated 23-12-2023 regarding the above subject. Please
find below our best prices.

A). SOIL

ITEM# DESCRIPTION STANDARD RATE (SR)

01 Washed Sieve Analysis with 75 micron sieve (#200) ASTM D-422 70/Test

02 Proctor Test (Moisture density relationship of cohesive soil) ASTM D-1557 130/Test
ASTM D-4253 &
03 Maximum & Minimum Index Density 110/Test
4254
04 Atterberg limits test ASTM D-4318 60/Test

05 Field density test (Minimum chargeable 10 Points/Visit) ASTM D-6938 30/Point


06 Standby Time (Waiting time) N.A. 40/Hour

07 Classification of Soil ASTM D-2487 50/Test

08 Correction Factor if required for Proctor Test ASTM D-4718 Free

09 Reducing samples of Soil ASTM C-702 Free

10 Moisture Content of Soil ASTM D-2216 Free

11 California Bearing Ratio ASTM D-1883 340/Test

Geotechnical Division: E-Mail: geotech@gulfconsult.com Website: www.gulfconsult.com


Head Office: P.O. Box 684-Al Khobar 31952 Tel: +966 3 8944468 / 8955036 / 8949872 Fax: +966 3 8949015
Jubail Support Industry: P.O.Box 10113 – Jubail 31961 Tel: +966 3 3410018 Fax: +966 3 3410017
‫مختبر الخليج لمواد البناء‬
GULF LABORATORY
For Construction Materials
C.R. # 2051050843
Ref. GCJ/Q/2522/23
Date: 24-12-2023
Page #: 2/6

(B) CONCRETE

Sampling of fresh concrete Cylinder /Cube


1 ASTM C-172 40/Cylinder
(Maximum 1 hour for per Set)
2 Slump testing of fresh Concrete ASTM C-143 20/Test

3 Temperature of fresh Concrete ASTM C-1064 15/Test

4 Compressive strength test of Cylinders or Cube ASTM C-39 38/Each

5 Density of Hardened Concrete - Free

6 Capping of Concrete cylinder for Compressive Strength ASTM C-617 Free

7 Compressive test of Hollow block ASTM C-140 40/Test

8 Unit Weight of Fresh Concrete - 40/Test

9 Air Content of Fresh Concrete ASTM C-173 40/Test

10 Compressive test of Cube (2”x2”x2”) ASTM C-109 25/Test

11 Standby Time (Waiting time) N.A. 40/Hour

12 Dry Film Thickness (Minimum 6 Test / Visit) ASTM D-6132 60/Each

13 Chloride Ion Permeability of Hardened Concrete ASTM C-1202 350/Sample

14 Schmidt Hammer Test (Minimum 2 Test / Visit) ASTM C-805 100/Each

15 Coating Adhesion Pull-off Test ASTM D-4541 150/Test

16 Preparation of sample for Rapid Chloride Test N.A. Free

(C) ASPHALT
ASTM D-
1 Asphalt extraction & gradation 150/Test
2172/D-5444
2 Max. Theoretical specific gravity ASTM D-2041 140/Test
3 Loss of stability (Set of 3) ASTM D-6927 150/Test

Geotechnical Division: E-Mail: geotech@gulfconsult.com Website: www.gulfconsult.com


Head Office: P.O. Box 684-Al Khobar 31952 Tel: +966 3 8944468 / 8955036 / 8949872 Fax: +966 3 8949015
Jubail Support Industry: P.O.Box 10113 – Jubail 31961 Tel: +966 3 3410018 Fax: +966 3 3410017
‫مختبر الخليج لمواد البناء‬
GULF LABORATORY
For Construction Materials
C.R. # 2051050843
Ref. GCJ/Q/2522/23
Date: 24-12-2023
Page #: 3/6

4 Marshall stability, flow & density ASTM D-6927 150/Test


5 Mob & Demob of core cutting machine N.A. 100/Visit
6 Coring by 4” in Asphalt (Per core/layer) N.A. 75/Core
7 Density of Asphalt Core ASTM D-2726 65/Core
8 Asphalt monitoring ASTM D-979 40/Hour
9 Spray Rate Test (Prime / Tack Coat) ASTM D-2995 75/Test
10 Standby Time (Waiting time) N.A. 40/Hour
11 Thickness of core ASTM D-3549 25/Test

(D) AGGREGATE

1 Specific Gravity & Absorption ASTM C-127/128 110/Test

2 Clay lumps & friable particles ASTM C-142 90/Test


3 Sieve Analysis of Aggregates ASTM C-136 50/Test
4 L.A. Abrasion Test (100 & 500 revolution) ASTM C-131/535 225/Test

5 Soundness test by Magnesium Sulfate ASTM C-88 275/Test


6 Acid / Water Soluble Sulfate BS-812 65/Test
7 Acid / Water Soluble Chloride BS-812 65/Test
8 Flakiness & Elongation Index ASTM D-4791 110/Test
9 Organic Impurities test on Fine Aggregates ASTM C-40 80/Test
10 Sand equivalent test ASTM D-2419 110/Test

(E) WATER

1 pH ASTM D-1293 30/Test


2 TDS ASTM D-5907 65/Test

Geotechnical Division: E-Mail: geotech@gulfconsult.com Website: www.gulfconsult.com


Head Office: P.O. Box 684-Al Khobar 31952 Tel: +966 3 8944468 / 8955036 / 8949872 Fax: +966 3 8949015
Jubail Support Industry: P.O.Box 10113 – Jubail 31961 Tel: +966 3 3410018 Fax: +966 3 3410017
‫مختبر الخليج لمواد البناء‬
GULF LABORATORY
For Construction Materials
C.R. # 2051050843
Ref. GCJ/Q/2522/23
Date: 24-12-2023
Page #: 4/6

3 Sulfate ASTM D-516 75/Test


4 Chloride ASTM D-512 75/Test
5 Full Chemical Analysis as per WHO (23 Parameters) As per WHO Std. 800/Test

(F) STEEL
Tensile, yield & elongation test on reinforcing steel ASTM A-370 250/Test/
1
Ranging from 10mm – 16mm diameter bar size Sample
Bend test of reinforcing steel ranging from 6mm-16mm ASTM A-370 160/Test/
2
Ranging from 10mm – 16mm diameter bar size Sample
Tensile, yield & elongation test on reinforcing steel ASTM A-370 350/Test/
3
Ranging from 20mm – 32mm diameter bar size Sample
Bend Test of reinforcing steel ranging from 20mm-32mm ASTM A-370 200/Test/
4
diameter bar size Sample
(Note :- Client has to provide 2 Nos. steel bars 72 cm length of each size)

(H) SITE VISIT

1 Site Visit for Each Field Work N.A. 100/Visit


2 Standby Time (Waiting time) N.A. 40/Hour
3 Soil Sampling from Site N.A. 100/Visit
Concrete Sample collection after 24 hours (If no testing on
4 N.A. 100/Visit
same day)
NOTE: -
• Purchase order duly signed by company representative are required to start the
job.
• ID has to be provided by client.
• Client has to provide One Helper for FDT & Concrete Work.
• 24 Hours prior notice required for each field testing.
• During Concrete & Asphalt work, client has to provide food for Technician.
• Shelter for Concrete Sampling area.

PAYMENT CONDITION: Full payment has to be settled at the time of releasing the report

Geotechnical Division: E-Mail: geotech@gulfconsult.com Website: www.gulfconsult.com


Head Office: P.O. Box 684-Al Khobar 31952 Tel: +966 3 8944468 / 8955036 / 8949872 Fax: +966 3 8949015
Jubail Support Industry: P.O.Box 10113 – Jubail 31961 Tel: +966 3 3410018 Fax: +966 3 3410017
‫مختبر الخليج لمواد البناء‬
GULF LABORATORY
For Construction Materials
C.R. # 2051050843
Ref. GCJ/Q/2522/23
Date: 24-12-2023
Page # 5/6

We hope our quotation will meet your approval. In case of approval please send P.O. with your official notice to
proceed.

Assuring you of our very best services at all times.

Very truly yours.


For GULF CONSULT
Geotechnical Division

RABAH YEHYA
General Manager

Geotechnical Division: E-Mail: geotech@gulfconsult.com Website: www.gulfconsult.com


Head Office: P.O. Box 684-Al Khobar 31952 Tel: +966 3 8944468 / 8955036 / 8949872 Fax: +966 3 8949015
Jubail Support Industry: P.O.Box 10113 – Jubail 31961 Tel: +966 3 3410018 Fax: +966 3 3410017
‫مختبر الخليج لمواد البناء‬
GULF LABORATORY
For Construction Materials
C.R. # 2051050843
REF# GCJ/Q/2522/23
DATE : 24.12.2023
Page # 6/6

Terms & Conditions:

1. Mobilization: Client to issue an official Purchase Order upon approval of the quotation.
2. Payment: Full payment has to be settled at the time of releasing the reports. For the Credit facilities, if payment is
not done on time as mutually agreed, GCSMT will have right to stop submitting reports until payment issue
resolved.
3. Value Added Tax (VAT): An amount equivalent to the mandatory percentage of the total invoice value
representing VAT will be applied
4. Validity : Validity of our cost proposal is 90 days from date of this Proposal.
5. Exclusion: The quoted rates for field tests are applicable only within our office normal working hours (7:00 AM
to 12:00 NN and 1:00 PM to 5:00 PM during weekdays & 7:00-12:00 NN during Thursday). In case fieldwork is
required outside regular working hours, additional SR 20 per hour will be charged.
6. Site Access: client is completely responsible in facilitating the application and eventual issuance of the necessary
access permits/IDs’ for GCSMT personnel, equipment and vehicle to enable our field crew gain an access to the
project location at no absolute cost to GCSMT.
7. Advance Notice: Client should give an advance notice, at least 24 hours, for site testing and/or sampling for an
on-call basis option.
8. Toxic & Hazardous Materials: It will be client’s obligation to voluntarily present GCSMT with sufficient
information readily available in his possession or knowledge on matters pertaining to the potential presence of
toxic or hazardous materials at the project site being investigated.
9. Warranty: GCSMT hereby extend its warranty that our services will be conducted in a manner consistent with
the level of case and skill ordinarily exercised by member of the profession currently practicing under similar
conditions. No other implied warranty is included or intended in our proposal.
10. Liability: For any unforeseen damage/s occurred on the account of human error, unintentional omission and other
professional negligence, we herein signify that our liability to compensate this unforeseen damage/s will be
limited to a sum not exceeding our fees charged form this particular undertaking.
11. Records: All pertinent records relating to testing services performed herein under shall be retained for a period of
not more than five (5) consecutive years after completion of work. Client shall have an access to the records, at all
reasonable times, during the mentioned period.
12. Reporting: Test reports shall be submitted within 1 week after completion of the test, as per the relevant test
standard and as per agreed payment condition.
13. Proper Storage and Disposal of Samples: Samples submitted to our laboratory for necessary testing services
will be discarded immediately after 30 days from the submission of our written report. Upon an official request,
we will be delivering the samples in accordance with the client’s instruction with corresponding charges or store
the sample/s longer than the specified period for an agreed fee.
14. Scaffoldings & Power supply: Necessary scaffolding and Power Supply of 110/220 volts will be provided by
client (in case necessary).
15. Propriety Information: “Propriety Information” Client request for Quotation in form of hard copy, digital, oral,
electronic to be treated as restricted and confidential in nature. Gulf Consult will not be disclosed to any Third
Party without Client consent.
16. Decision Rule: a). Decision Rule shall be implemented to determine the conformity of test result.
b). Decision rule shall take measurement uncertainty into account.
c). Decision rule shall be agreed with the customer before starting the test.
d). Decision rule shall be implemented when required.
e). Decision Rule Adopted: when the Test Result + the value of expanded uncertainty is
within the limits of the test, then the result is considered Pass. IF Test Result + the value of
expanded uncertainty is fully or partially outside the test limits, then the result is considered
Fail.
Form No. : GC/GEN/J011
Issue No.: 01
Issue Date : 01-01-2017

Geotechnical Division: E-Mail: geotech@gulfconsult.com Website: www.gulfconsult.com


Head Office: P.O. Box 684-Al Khobar 31952 Tel: +966 3 8944468 / 8955036 / 8949872 Fax: +966 3 8949015
Jubail Support Industry: P.O.Box 10113 – Jubail 31961 Tel: +966 3 3410018 Fax: +966 3 3410017

You might also like