This calibration is used to memorize the power shift pressure for the proportional reducing valve. Be sure to
perform this calibration when the proportional reducing valve or the controller has been replaced.
1. Install a pressure gauge of 4900 kPa (710 psi) to the tap for the power shift pressure.
Illustration 1 g00688851
5. Highlight the second line by using the arrow keys. Scroll through the display on the second line until the
display shows "CALIBRATION" by using the arrow keys.
Illustration 2 g00689451
6. Highlight the third line by using the arrow keys. The name of the device for the calibration is displayed on
the third line. Scroll through the display until the display shows "PS PRV" by using the arrow keys. The
power shift pressure is calibrated for the low pressure and the high pressure.
Illustration 3 g00689455
7. The area that is highlighted is moved to the right side by using the "menu" key in order to change between
low pressure and high pressure. Then, the arrow keys are used in order to change the display from low
pressure to high pressure.
Illustration 4 g00689465
8. Highlight the fourth line by using the arrow keys. Then, change the value. Press the "OK" key.
Illustration 5 g00689483
9. The fourth line will show a numerical value. The engine speed should be increased to a position of 10 on
the engine speed dial. The pressure gauge will indicate the actual power shift pressure. Note the actual
value that is shown on the pressure gauge. Use the left arrow key and the right arrow key to enter the
value that is shown on the pressure gauge into the fourth line of the display on the monitor. The value
should be set as close to the actual pressure as possible. The power shift pressure will change by
approximately 30 kPa (4.3 psi) per step. The monitor can correct the pressure by ±30 kPa (4.3 psi).
10. The "setting" key is pressed in order to save the value of the power shift pressure. After the value has been
saved, the third line will be highlighted.
Illustration 6 g00689488
11. Refer to the following table 1 if an error is present on the display. The error will be displayed on the fourth
line of the message center.
Table 1
List Of Error Codes
Display Description Of The
Corrective Action
Error
ERROR Being calibrated by Stop the calibration of the other component. Perform
01 another device calibration again.
ERROR Being calibrated by Stop the calibration of the other component. Perform
02 another module calibration again.
ERROR Failure of the interlock Troubleshoot the confirmation of the signals for
03 signal communication.
ERROR Abnormal component Confirm the active error code. Troubleshoot the problem
21 operation according to the component.