SW6 Instr G
SW6 Instr G
ABB Automation
This unit is equipped with software
15.208 CON-2
15.610 AMC-DC
DCS600_E MultiDrive
Solved problem
• Emergency STOP supervision for long ramp times
• Main contactor off time delay of 3-phase field exciter units
• Start synchronization outside the limits 49.5...61 Hz
• LED panel parameter selection (18.1) is lost after power down
• F33 for field currents above 165 A
Revision History
The difference between 15.609 to 15.610 is:
• a new control input for DC Break trip (current rise detection)
• a new alarm * for missing Acknowledge, DC Breaker, Dynamic Brake
• Temperature Alarm Level 5°C below Fault Level
* in the combination 15.208/15.609, the alarm displays a <undefined Alarm> (9.05 bit 15)
Cross reference list
Changed Signals and Parameters
(in relation to the previous software release)
Release
1 Compatibility to ACS600 Reason Index Name Scaling / Limits Index Name Scaling / Limits
2 Added function 2 70.21 CH0 HW CONNECTION
3 Clean-up 2 20.18 CURRENT RISE MAX
2 17.06 INDX SQUARE WAVE
2 42.14 CONV TEMP DELAY
2 4.23 CON SW PRERELEASE 4.23 CON SW SUBRELEASE
2 4.24 AMC SW PRERELEASE 4.24 AMC SW SUBRELEASE
2 8.08 DRIVE STATE
2 42.06 NOM SUPPLY VOLT int. minimum 50 V 42.06 NOM SUPPLY VOLT int. minimum 40 V
; check parameter files
< check application
3ADW 000 119 R0701 REV G