Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 2

Pole Embedment Design Program

POLE EMBEDMENT DESIGN

Adversely affected by a 1/2 inch


Allowable Lateral Pressure 600 psf / ft motion at the ground surface
Allowable Foundation Pressure = 1500 psf N [Y or N]
Maximum Lateral Pressure = 9000 psf

Pole Shape = S Circular [C] or Square [S]


Width = 31.50 in
Lateral Restraint N [Y or N]

Lateral Force = 2000 pounds


Vertical Load = 1000 pounds
Height to Load = 8.50 ft
Moment at Base = 17000 ft-pounds
Allowable Lateral
Trial Depth= 3.41 ft Pressure = 1364 psf
Depth Required= 3.42 ft
Embedment Depth Required = 3.42 ft

Foundation Pressure = 145 psf <= 1500 psf (OK)

This spreadsheet is provided for illustrative teaching purposes only and is not intended for
use on any specific project. Anyone using the information contained on this spreadsheet
does so at his/her own risk and assumes all resulting liability arising therefrom.

© John W. Andrew, PE
ntended for