Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20)

SLV20
Load sensing proportional modular directional control valve
Up to 250Bar (3600 psi) and 30 L/min (10 USgpm)
SLV20

INTRODUCTION....................................................................................................................................................... 3

Features, Benefits & Applications................................................................................................................. 3

Technical Specifications................................................................................................................................ 4

Principle of Operation................................................................................................................................... 4

Priority Flow Sharing..................................................................................................................................... 5

Performance Data......................................................................................................................................... 6

CONFIGURATION & ORDERING GUIDELINES..................................................................................................... 7

INLET SECTIONS..................................................................................................................................................... 9

Inlet Section Composition Details...............................................................................................................10

WORK SECTIONS.................................................................................................................................................. 15

Work Section Composition Details............................................................................................................. 16

END COVERS......................................................................................................................................................... 20

TRANSITION PLATES............................................................................................................................................ 20

TIE ROD KITS......................................................................................................................................................... 21

2 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Introduction

The SLV20 valve is a compact, lightweight solution for low-flow applications that require load
sensing and flow sharing. Designed in sections to facilitate stacking of multiple functions,
the SLV20 utilizes the new Eaton ESV9 four-way three-position proportional solenoid cartridge
valve in a hydraulic integrated circuit concept.

Features, Benefits & Applications


• Load sensing and priority • Eaton ESV9 four-way • Patent-pending
flow sharing for low-flow three-position proportional multifunction compensator
machinery with the flexibility solenoid cartridge valve reduces section size by
of screw-in cartridge valves features best-in-class 40%, making overall system
hysteresis and flow simple and compact
• Pre- and post-compensation performance
options offer flow sharing • Pro-FX Ready™ for easy
and flow prioritization • Aluminium sections reduce integration with other Eaton
weight, which can increase Pro-FX Ready products
• Multiple inlet section options efficiency, load carrying
accommodate range of capability and battery life • Can be used in open-center
pump options and closed-center systems
• Load control section offers
• Flexible mounting stable load control • Configurable functionality &
improved serviceability
• Low system cost

The main advantage of this system is flexibility. SLV20 valve sections are manufactured from aluminium drawn bar, which
makes it possible to produce small batches of individual sections with added functions, such as pilot-operated check valves or
counterbalance valves, or other more customised requests. This reduces the need for remotely mounted ancillary valves to perform
other system functions. Sequencing and regeneration can also be achieved using this method.

The SLV20 valve offers the ideal flow rate for mini and micro machinery platforms in the following industries:
• Construction: excavators, wheel loaders, skid steer loaders, trenchers
• Agriculture: smaller tractors and tractor attachments
• Material handling: spider cranes, truck-mounted cranes, various aerial work platforms, lift trucks, telehandlers
• Vocational vehicles: snow and ice management, road sweepers, lawnmowers
• Auxiliary/accessory control on larger machines i.e. outriggers

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 3
SLV20
Introduction

Technical Specifications
Specifications
Rated Work Port & Inlet Pressure 250 bar
Rated Tank Pressure 10 bar
Rated Work Port Flow @ 10 bar dP 22 L/min
Rated Work Port Flow @ 14 bar dP 30 L/min
Max Inlet Flow 60 L/min
Construction Sectional
Max Sections per Assembly 6
Manual Override Optional – push/pull knob
Average Work Section Weight 3kg
Inlet/End Plate Weight 3kg
Electrical Coils IP69K Large Tough coils*
Coil Power 28W
Coil Voltages 12 Volt DC
24 Volt DC
Temperature Range -40° to 120°C (-40° to 248°F)
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration ISO 4406 cleanliness code 18/16/13 or better
Electrohydraulic Interface Eaton HFX programmable controllers
Pro-FX™ application software
*See Section C for full coil details. Not all Coil connection options are rated to IP69K

Principle of Operation
Neutral condition Pre-compensation
In the neutral condition, when no command signal is given, the In pre-compensated work sections, the compensator is
load sense line signal is communicated to the pump load sense located upstream of the metering orifice, created by the main
port or the control chamber of inlet compensator. In open-center spool movement. The flow, therefore passes first through
systems the compensator in the inlet section opens and dumps the compensator and then through the metering orifice. In
the entire flow to tank while in closed-center systems the pump each work section the load sense pressure is sensed by the
de-strokes. compensator maintaining a constant pressure drop across the
metering orifice. During pump saturation, where flow demand
Working condition exceeds the pump flow, the actuator pressure is sensed by the
When a command signal is given to the valve in the work compensator in each work section. The work section with the
section the load sense line senses pressure from the service highest-pressure requirement will lose flow while the lower
line A or B subsequently increasing the inlet flow, either by pressure sections are unaffected. When used in combination
increasing the pump output or in the case of a fixed pump with Post-compensated work sections the Pre-compensated
closing the inlet compensator. The flow is accordingly directed work sections will take priority.
to port A or to Port B. During multifunction operation the
local compensator in each work section maintains a constant Post-compensation
pressure drop across the main spool as the inlet pressure In post-compensated work sections, the compensators are
changes. For applications with a fixed displacement pump the located downstream of the metering orifice, created by the
inlet compensator maintains a constant pressure drop across all spool movement. The flow therefore passes first through the
sections. metering orifice and then through the compensator. During
pump saturation, where flow demand exceeds the pump flow,
post compensation provides flow sharing as the highest actuator
pressure is sensed by all of the local compensators. This gives a
proportionate reduction in flow to all actuators.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

4 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Introduction

Figure 1: Simple Post-Compensated SLV20 Work Section Figure 2: Simple Pre-Compensated SLV20 Work Section

Priority Flow Sharing


By combining post-compensated and pre-compensated sections in a single assembly, priority flow sharing can be achieved. During
pump saturation condition flow to actuators connected to post-compensated sections is reduced proportionally, while at the same
time flow to actuators connected to pre-compensated sections maintain a constant flow rate. This allows for function prioritisation
while enhancing system the safety and efficiency.

Figure 3: Basic 6 post-compensated work section assembly (electrohydraulic actuation)

Figure 4: Basic 6 pre-compensated work section assembly (electrohydraulic actuation)

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 5
SLV20
Introduction

Performance Data
Inlet Relief Valve Inlet Dump Valve
Pressure override for inlet load sense or main relief valve option Pressure drop for normally open inlet dump valve option

Pressure Compensation Flow Sharing


Typical pressure compensation performance for single Typical flow sharing performance during flow saturation for post-
pre-comp or post-comp work section at 1.5A command signal compensated work sections only
30 35
Work Port Flow (lpm)

25 30

20 25
Flow (lpm)

15 20

10 15

5 10

5
0
0 50 100 150 200 250 300
0
Work Port Pressure (bar) 0 5 10 15 20 25 30 35 40 45 50
Time (s)
Inlet Section 1 Work Port A Section 2 Work Port A
Flow vs Command Signal
Work Port Flow vs Current at 10bar ∆P with 12V Coil for
Pre-Comp and Post-Comp Sections for Both E and F Spools

Note: The SLV20 valve uses the ESV9-10 for directional control and metering, for further details on the individual valve please refer to SICV catalogue
Proportional Section B, Page B-34.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

6 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Configuration & Ordering Guidelines

Configuration & Ordering Guidelines


Each standard assembly must consist of:
• 1x Inlet section
• 1 to 6 Work sections
• 1x End cover
• 1x Tie rod kit

• When using post-compensated and pre-compensated sections • If attaching an SLV20 assembly to an Eaton mobile valve, such
next to each other in a standard configuration assembly, as CLS or CMT, an Inter-product transition plate must be used,
a transition plate must be used. these are available upon request.
• For a Mid-inlet assembly configuration, an additional End cover • Please contact us if a custom Work or Inlet section is needed
is needed, and a Mid-inlet tie rod kit must be requested. with specifications different to that shown in the catalogue.
• If there is a requirement to create an assembly with more • Assemblies are configured and built from left to right
than 6 work sections, please contact us to see if we can i.e: standard inlet first on the left, and end cover last
facilitate this request. on the right.

Mid-Inlet Configuration
• 1x End cover
• 1 to 3 Work sections
• 1x Mid-inlet section
• 1 to 3 Work sections
• 1x End cover
• 1x Tie rod kit

Valve bank order example

Item Section Model Code


1 Inlet SLV20IPOLRZ000000ZZ00A

2 Section 1 SLV20WPOAECR050ZZ000R050ZZ00000A

3 Section 2 SLV20WPOAECR050ZZ000R050ZZ00000A

4 Section 3 SLV20WPOAECR050ZZ000R050ZZ00000A

5 Transition Plate SLV20T00A

6 Section 4 SLV20WPRAFCR050ZZ000R050ZZ00000A

7 Section 5 SLV20WPRAFCR050ZZ000R050ZZ00000A

8 End Cover SLV20ERZ00A

9 Tie Rod Kit SLV20M/5

Note: Repeat section model code for additional sections.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 7
SLV20
Configuration & Ordering Guidelines

Dimensions

Dimensions Number of Sections - Standard Configuration


1 2 3 4 5 6

X (mm) 110 160 210 260 310 360

Y (mm) Max 150 200 250 300 350 400

Weight (Kg) 6 9 12 15 18 21

Note: The assembly dimensions will differ when work port load holding options are chosen.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

8 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Inlet Sections

Inlet Sections

Model code: SLV20I XX (X) X X X XXX XXX X X 00 A

1-6 7-8 9 10 11 12 13-15 16-18 19 20 21-22 23

1-6 Product Series 11 Inlet Relief 16-18 


Main Relief Setting 21-22 Special Features
SLV20I - Sectional Load D - Load Sense and Main XXX - 0 00-250 (3 Digit, in 00 - No Special Features
Sense Valve Standard Inlet Relief Valve 5 Bar Increments) Main
Section L - Load Sense Relief Relief Pressure Setting, 23 Design Level
Code 000 if none.
Valve Only A - Initial Release
7-8 Compensation R - Main Relief Valve Only
19 Inlet Dump Valve
PR - Pre-Comp. Inlet Z - No Reliefs
F - Main Flow Dump Valve for
PO - Post-Comp. Inlet Unload Inlet
12 Inlet LS Shuttle
MI - Mid-Inlet L - Load Sense Dump Valve
S - Load Sense Shuttle Valve
for Unload Inlet
9 Seal Material Z - No Load Sense
Z - No Inlet Dump Valve
Shuttle Valve
Blank - Buna-N
V - V iton® 20 Coil Type*
13-15  
Load Sense Relief
Setting C - 12V Coil Deutsch Connector
10 Inlet Type
XXX - 0 00-250 (3 Digit, D - 24V Coil Deutsch Connector
L - Load Sensing
in 5 Bar Increments) E - 12V Coil AmpJr Connector
(variable disp. pumps)
Load Sense Relief
U - Unload Inlet for Open Pressure Setting, F - 24V Coil AmpJr Connector
Center (fixed disp. Pumps) Code 000 if none. Z - No Coil

Note: Default P & T port cavities SAE. Contact us for BSP

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 9
SLV20
Inlet Sections

Inlet Section Composition

Model Code Position: 10 Inlet Type

L - Load Sensing U - Unload for Open Center


The inlet section with L configuration enables usage with The inlet section with U configuration enables usage with fixed
variable displacement pumps for closed loop systems and displacement pumps for open loop systems. The DPS2-10 logic
features, as standard, no active components. element in the inlet section acts as an unloader, bypassing
excess flow to tank, to enable the load sensing functionality.

Figure 5: L - Basic Load Sensing Inlet Section Circuit Figure 6: U - Basic Unloading Inlet Section Circuit

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

10 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Inlet Sections

Inlet Section Composition

Model code position: 11 Inlet Relief

A load sense relief valve can be used to adjust the system


maximum pressure and a main relief valve can be used to
protect the system from pump regulator failures.

D - Load Sense and Main Relief Valve L - Load Sense Relief Valve Only

Figure 7: D
 - Load Sense and Main Relief Valve Inlet Option Figure 8: L - Load Sense Relief Valve Only Inlet Option Circuit
Circuit

Note: This combination requires the main relief valve to be set at least
40 bar higher than the load sense relief valve.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 11
SLV20
Inlet Sections

Inlet Section Composition

Model code position: 11 Inlet Relief

M - Main Relief Valve Only

Figure 9: M - Main Relief Valve Only Inlet Option Circuit

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

12 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Inlet Sections

Inlet Section Composition

Model Code Position 12: Inlet Load Sense Shuttle

S – Load Sense Shuttle Valve


The load sense shuttle option is for when the SLV20 and
another load sensing valve are both used together with a single
variable displacement pump. The LS shuttle will compare the
load sense signal from SLV20 and the other load sense valve
and communicate the highest load signal back to the variable
displacement pump so it can fulfil the requirement of both
valves.

Figure 10: L – Load Sense Shuttle Valve Inlet Option Circuit

Note: LS OUT connects to the Pump and LS IN comes from the other
load sense valve.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 13
SLV20
Inlet Sections

Inlet Section Composition

Model Code Position 19: Inlet Dump Valve

F – Main Flow Dump Valve L – Load Sense Dump Valve


The main flow dump valve is typically used with fixed The load sense flow dump valve is typically used with variable
displacement pumps for open loop systems. The normally open displacement pumps for closed loop systems. The normally
solenoid valve, unless actuated, bypasses all inlet flow to tank. open solenoid valve, unless actuated, bypasses the load sense
signal to tank.

Figure 11: F – Main Flow Dump Valve Inlet Option CircuitCircuit Figure 12: L – Load Sense Dump Valve Inlet Option Circuit

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

14 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Work Sections

Work Sections

Model code: SLV20W XX (X) X X X X XXX X X X XX X XXX X X X XX 00 A

1-6 7-8 9 10 11 12 13 14-16 17 18 19 20-21 22 23-25 26 27 28 29-30 31-32 33

1-6 Product Series 13  


Port A Function 19  
Port A Load Holding 27  
Port B Load Holding
SLV20W - Sectional Load Option Pilot Ratio** Adjustment**
Sense Valve Standard Work A - Anti-Cavitation 0 - Code 0 if none. N - Fixed
Section 2 - 2:1
R-R
 elief/Anti-Cavitation Z - Screw Adjustment
3 - 3:1
Z - None 4 - 4:1 F - None
7-8 Compensation
5 - 5:1
PR - Pre-Compensated 8 - 8:1 28  
Port B Load Holding
14-16 
Port A Option
PO - Post-Compensated Pilot Ratio**
Settings 1 - 10:1
0 - Code 0 if none.
9 Seal Material XXX - 0
 40-250 (3 Digit, 20-21  
Port A Load Holding
in 10 Bar Increments) 2 - 2:1
Blank - Buna-N Option Settings
Relief Valve Pressure 3 - 3:1
V - Viton® XX - 07-25 (2 Digit, in 10
Setting. Code 000 Bar Increments) Load 4 - 4:1
if none Holding Relief Pressure
10 Actuation 5 - 5:1
Setting. Code 00 if none.
A - Electrohydraulic Only 17   8 - 8:1
Port A Load Holding
B - Electrohydraulic with Options 22  
Port B Function 1 - 10:1
Manual Override Option
P-P
 ilot Operated Check Valve
A - Anti-Cavitation 29-30  
Port B Load Holding
11 Spool Type C - Standard Overcenter Valve R - Relief/Anti-Cavitation Option Settings
E - Double Acting (4 way) R - Part Balanced Overcenter Z - None XX - 07-25 (2 Digit, in
Cylinder Spool Valve 10 Bar Increments) Load
23-25  
Port B Option Holding Relief Pressure
F - Double Acting (4 way) B-F
 ully Balanced Overcenter
Settings Setting. Code 00 if none.
Motor Spool Valve
XXX - 0 40-250 (3 Digit, in
L-T
 wo Stage Overcenter Valve 31-32 Special Features
10 Bar Increments)
12  
Coil Type*
Z - None Relief Valve Pressure 00 - No Special Features
C - 12V Coil Deutsch Setting. Code 000
Connector if none.
18  
Port A Load Holding 33  
Design Level
D - 24V Coil Deutsch Adjustment**
Connector 26  
Port B Load Holding A - Initial Release
E - 12V Coil AmpJr Connector
N - Fixed Options
F-S
 crew Adjustment P - Pilot Operated Check Valve
F - 24V Coil AmpJr Connector
C - Standard Overcenter Valve
Z - No Coil Z - None R-P  art Balanced Overcenter Valve
B - F ully Balanced Overcenter Valve
L - Two Stage Overcenter Valve
Z - None

Note: *See Section C for further coil details, other coil connectors available but not all IP69K
** Pilot open check valves are only available in fixed adjustment and limited to a 3:1 Pilot ratio only
Not all types of Overcenter valves are available in all pilot ratio options. Refer to SiCV catalogue section F for valve details.
Overcenter valves are also refer to as 'counterbalance' or 'motion control' valves.
Default A & B work port cavities SAE. Contact us for BSP

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 15
SLV20
Work Sections

Work Section Composition

Model Code Position 10: Actuation

A - Electrohydraulic B - Electrohydraulic with Manual Override

Dimensions

Note: Refer to SICV Catalog Proportional Section B, Page B-36 for more details on the manual override option.

Model Code Position 11:


Spool Type

E – Double Acting Cylinder Spool F – Double Acting Motor Spool


2 4 2 4

COIL COIL COIL COIL


B A B A
3 1
Figure 13: E
 – 4 Way All Ports Closed Center Cylinder Spool Figure 14: F
 – 4 Way Work Ports to Tank Center Motor Spool
ConfigurationCircuit Configuration

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

16 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Work Sections

Work Section Composition

Model code position 17 & 26: Load Holding Options

P – Pilot Operated Check Valve C – Standard Overcenter Valve


The pilot check valve option uses the 4CK30 valve which has The standard overcenter valve option uses the 1CE30 valve and
a pilot ratio of 3:1. Refer to SICV Catalog Check Section G, the available pilot ratio options are 2.5:1, 5:1 and 10:1. Refer
Page G-42 for more details. to SICV Catalog Motion Control Section F, Page F-12 for more
details.

Figure 15: P
 - Pilot Operated Check Valve Option Figure 16: C
 - Standard Overcenter Valve Option
on Post-compensated Work Section on Post-compensated Work Section

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 17
SLV20
Work Sections

Work Section Composition

Model code position 17 & 26: Load Holding Options

R – Part Balanced Overcenter Valve B – Fully Balanced Overcenter Valve


The part balanced overcenter valve option uses the 1CER30 The fully balanced overcenter valve option uses the 1CEBD30
valve and the available pilot ratio options are 2.5:1 and 4:1. Refer valve with the pilot ratio of 5:1. Refer to SICV Catalog Motion
to SICV Catalog Motion Control Section F, Page F-16 for more Control Section F, Page F-20 for more details.
details.

Figure 17: R
 - Part Balanced Overcenter Valve Option Figure 18: B
 - Fully Balanced Overcenter Valve Option
on Post-compensated Work Section on Post-compensated Work Section

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

18 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Work Sections

Work Section Composition

Model code position 17 & 26: Load Holding Options

L – Two Stage Overcenter Valve


The two stage overcenter valve option uses the 1CEL30 valve
with a primary pilot ratio of 4.3:1 and a secondary pilot ratio
of 0.4:1. Refer to SICV Catalog Motion Control Section F,
Page F-24 for more details.

Figure 19: L
 – Two Stage Overcenter Valve Option
on Post-compensated Work Section

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 19
SLV20
End Covers

End Covers

Model code: SLV20E (X) X X 00 A

1-6 7 8 9 10-11 12

1-6 Product Series 8 Side Configuration 9 Extra Port Options 10-11 Special Features
SLV20E - Sectional Load R - Right-side end cover for A - End cover with P and 00 - No Special Features
Sense Valve Standard End Standard Config. T ports
Cover L - Left-side end cover for 12 Design Level
Z - None
Mid-inlet Config. A- Initial Release
7 Seal Material
Blank - Buna-N
V - Viton®

Note: Default P & T port cavities SAE. Contact us for BSP

Transition Plates

Model code: SLV20T (X) XX A

1-6 7 8-9 11

1-6 Product Series 7 Seal Material 8-9 Special Features 11 Design Level
SLV20T - Sectional Load Blank - Buna-N 00 - No Special Features A- Initial Release
Sense Valve Standard V - Viton®
Transition Plate

Note: A standard transition plate can be used to transition from a pre to a post-compensated work section,
or from a post to a pre-compensated work section in an assembly.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

20 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Tie Rod kits

Tie Rod kits


Tie rod kits are required to complete a valve assembly. Tie rod length depends on the number and
type of sections in the assembly. Each tie rod kit includes 3x Tie Rods, 3x M10 nuts, 3x Washers,
and 3x Spring Washers.

Standard Sections
Approximate
Tie Rod Kit Description
Length (mm)
SLV20/1 1 Section 120

SLV20/2 2 Section 165

SLV20/3 3 Section 215

SLV20/4 4 Section 265

SLV20/5 5 Section 315


SLV20/6 6 Section 365

Mid-inlet & Transition Plate Configurations


The SLV20M tie rod kits are for mid-inlet configuration assemblies or standard configuration
assemblies that use one Pre/Post-compensation transition plate.

Sections with Mid-Inlet


Approximate
Tie Rod Kit Description
Length (mm)
SLV20M/1 1 Section 190

SLV20M/2 2 Section 240

SLV20M/3 3 Section 290

SLV20M/4 4 Section 340

SLV20M/5 5 Section 390

SLV20M/6 6 Section 440

Note: Please contact us to confirm the tie rod kit needed if any doubt,
or to request a tie rod length that is not listed above.

Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.

Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 21
Eaton
Hydraulics Group USA
14615 Lone Oak Road
Eden Prairie, MN 55344
USA
Tel: 1-800-386-1911

Eaton
Hydraulics Group Europe
Route de la Longeraie 7
1110 Morges
Switzerland
Tel: +49 7221 682 456

Eaton
Hydraulics Group Asia Pacific
Eaton Building
No.7 Lane 280 Linhong Road
Changning District, Shanghai
200335 China
Tel: (+86 21) 5200 0099
Fax: (+86 21) 2230 7240

Follow us on social media to get the


© 2020 Eaton Eaton is a registered trademark. latest product and support information.
All Rights Reserved
Publication No. E-VLSC-CC002-E All other trademarks are property
December 2020 of their respective owners.