SLV20
Load sensing proportional modular directional control valve
Up to 250Bar (3600 psi) and 30 L/min (10 USgpm)
SLV20
INTRODUCTION....................................................................................................................................................... 3
Technical Specifications................................................................................................................................ 4
Principle of Operation................................................................................................................................... 4
Performance Data......................................................................................................................................... 6
INLET SECTIONS..................................................................................................................................................... 9
WORK SECTIONS.................................................................................................................................................. 15
END COVERS......................................................................................................................................................... 20
TRANSITION PLATES............................................................................................................................................ 20
2 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Introduction
The SLV20 valve is a compact, lightweight solution for low-flow applications that require load
sensing and flow sharing. Designed in sections to facilitate stacking of multiple functions,
the SLV20 utilizes the new Eaton ESV9 four-way three-position proportional solenoid cartridge
valve in a hydraulic integrated circuit concept.
The main advantage of this system is flexibility. SLV20 valve sections are manufactured from aluminium drawn bar, which
makes it possible to produce small batches of individual sections with added functions, such as pilot-operated check valves or
counterbalance valves, or other more customised requests. This reduces the need for remotely mounted ancillary valves to perform
other system functions. Sequencing and regeneration can also be achieved using this method.
The SLV20 valve offers the ideal flow rate for mini and micro machinery platforms in the following industries:
• Construction: excavators, wheel loaders, skid steer loaders, trenchers
• Agriculture: smaller tractors and tractor attachments
• Material handling: spider cranes, truck-mounted cranes, various aerial work platforms, lift trucks, telehandlers
• Vocational vehicles: snow and ice management, road sweepers, lawnmowers
• Auxiliary/accessory control on larger machines i.e. outriggers
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 3
SLV20
Introduction
Technical Specifications
Specifications
Rated Work Port & Inlet Pressure 250 bar
Rated Tank Pressure 10 bar
Rated Work Port Flow @ 10 bar dP 22 L/min
Rated Work Port Flow @ 14 bar dP 30 L/min
Max Inlet Flow 60 L/min
Construction Sectional
Max Sections per Assembly 6
Manual Override Optional – push/pull knob
Average Work Section Weight 3kg
Inlet/End Plate Weight 3kg
Electrical Coils IP69K Large Tough coils*
Coil Power 28W
Coil Voltages 12 Volt DC
24 Volt DC
Temperature Range -40° to 120°C (-40° to 248°F)
Fluids All general purpose hydraulic fluids such as:
MIL-H-5606, SAE 10, SAE 20, etc.
Filtration ISO 4406 cleanliness code 18/16/13 or better
Electrohydraulic Interface Eaton HFX programmable controllers
Pro-FX™ application software
*See Section C for full coil details. Not all Coil connection options are rated to IP69K
Principle of Operation
Neutral condition Pre-compensation
In the neutral condition, when no command signal is given, the In pre-compensated work sections, the compensator is
load sense line signal is communicated to the pump load sense located upstream of the metering orifice, created by the main
port or the control chamber of inlet compensator. In open-center spool movement. The flow, therefore passes first through
systems the compensator in the inlet section opens and dumps the compensator and then through the metering orifice. In
the entire flow to tank while in closed-center systems the pump each work section the load sense pressure is sensed by the
de-strokes. compensator maintaining a constant pressure drop across the
metering orifice. During pump saturation, where flow demand
Working condition exceeds the pump flow, the actuator pressure is sensed by the
When a command signal is given to the valve in the work compensator in each work section. The work section with the
section the load sense line senses pressure from the service highest-pressure requirement will lose flow while the lower
line A or B subsequently increasing the inlet flow, either by pressure sections are unaffected. When used in combination
increasing the pump output or in the case of a fixed pump with Post-compensated work sections the Pre-compensated
closing the inlet compensator. The flow is accordingly directed work sections will take priority.
to port A or to Port B. During multifunction operation the
local compensator in each work section maintains a constant Post-compensation
pressure drop across the main spool as the inlet pressure In post-compensated work sections, the compensators are
changes. For applications with a fixed displacement pump the located downstream of the metering orifice, created by the
inlet compensator maintains a constant pressure drop across all spool movement. The flow therefore passes first through the
sections. metering orifice and then through the compensator. During
pump saturation, where flow demand exceeds the pump flow,
post compensation provides flow sharing as the highest actuator
pressure is sensed by all of the local compensators. This gives a
proportionate reduction in flow to all actuators.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
4 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Introduction
Figure 1: Simple Post-Compensated SLV20 Work Section Figure 2: Simple Pre-Compensated SLV20 Work Section
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 5
SLV20
Introduction
Performance Data
Inlet Relief Valve Inlet Dump Valve
Pressure override for inlet load sense or main relief valve option Pressure drop for normally open inlet dump valve option
25 30
20 25
Flow (lpm)
15 20
10 15
5 10
5
0
0 50 100 150 200 250 300
0
Work Port Pressure (bar) 0 5 10 15 20 25 30 35 40 45 50
Time (s)
Inlet Section 1 Work Port A Section 2 Work Port A
Flow vs Command Signal
Work Port Flow vs Current at 10bar ∆P with 12V Coil for
Pre-Comp and Post-Comp Sections for Both E and F Spools
Note: The SLV20 valve uses the ESV9-10 for directional control and metering, for further details on the individual valve please refer to SICV catalogue
Proportional Section B, Page B-34.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
6 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Configuration & Ordering Guidelines
• When using post-compensated and pre-compensated sections • If attaching an SLV20 assembly to an Eaton mobile valve, such
next to each other in a standard configuration assembly, as CLS or CMT, an Inter-product transition plate must be used,
a transition plate must be used. these are available upon request.
• For a Mid-inlet assembly configuration, an additional End cover • Please contact us if a custom Work or Inlet section is needed
is needed, and a Mid-inlet tie rod kit must be requested. with specifications different to that shown in the catalogue.
• If there is a requirement to create an assembly with more • Assemblies are configured and built from left to right
than 6 work sections, please contact us to see if we can i.e: standard inlet first on the left, and end cover last
facilitate this request. on the right.
Mid-Inlet Configuration
• 1x End cover
• 1 to 3 Work sections
• 1x Mid-inlet section
• 1 to 3 Work sections
• 1x End cover
• 1x Tie rod kit
2 Section 1 SLV20WPOAECR050ZZ000R050ZZ00000A
3 Section 2 SLV20WPOAECR050ZZ000R050ZZ00000A
4 Section 3 SLV20WPOAECR050ZZ000R050ZZ00000A
6 Section 4 SLV20WPRAFCR050ZZ000R050ZZ00000A
7 Section 5 SLV20WPRAFCR050ZZ000R050ZZ00000A
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 7
SLV20
Configuration & Ordering Guidelines
Dimensions
Weight (Kg) 6 9 12 15 18 21
Note: The assembly dimensions will differ when work port load holding options are chosen.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
8 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Inlet Sections
Inlet Sections
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 9
SLV20
Inlet Sections
Figure 5: L - Basic Load Sensing Inlet Section Circuit Figure 6: U - Basic Unloading Inlet Section Circuit
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
10 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Inlet Sections
D - Load Sense and Main Relief Valve L - Load Sense Relief Valve Only
Figure 7: D
- Load Sense and Main Relief Valve Inlet Option Figure 8: L - Load Sense Relief Valve Only Inlet Option Circuit
Circuit
Note: This combination requires the main relief valve to be set at least
40 bar higher than the load sense relief valve.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 11
SLV20
Inlet Sections
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
12 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Inlet Sections
Note: LS OUT connects to the Pump and LS IN comes from the other
load sense valve.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 13
SLV20
Inlet Sections
Figure 11: F – Main Flow Dump Valve Inlet Option CircuitCircuit Figure 12: L – Load Sense Dump Valve Inlet Option Circuit
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
14 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Work Sections
Work Sections
Note: *See Section C for further coil details, other coil connectors available but not all IP69K
** Pilot open check valves are only available in fixed adjustment and limited to a 3:1 Pilot ratio only
Not all types of Overcenter valves are available in all pilot ratio options. Refer to SiCV catalogue section F for valve details.
Overcenter valves are also refer to as 'counterbalance' or 'motion control' valves.
Default A & B work port cavities SAE. Contact us for BSP
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 15
SLV20
Work Sections
Dimensions
Note: Refer to SICV Catalog Proportional Section B, Page B-36 for more details on the manual override option.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
16 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Work Sections
Figure 15: P
- Pilot Operated Check Valve Option Figure 16: C
- Standard Overcenter Valve Option
on Post-compensated Work Section on Post-compensated Work Section
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 17
SLV20
Work Sections
Figure 17: R
- Part Balanced Overcenter Valve Option Figure 18: B
- Fully Balanced Overcenter Valve Option
on Post-compensated Work Section on Post-compensated Work Section
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
18 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Work Sections
Figure 19: L
– Two Stage Overcenter Valve Option
on Post-compensated Work Section
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 19
SLV20
End Covers
End Covers
1-6 7 8 9 10-11 12
1-6 Product Series 8 Side Configuration 9 Extra Port Options 10-11 Special Features
SLV20E - Sectional Load R - Right-side end cover for A - End cover with P and 00 - No Special Features
Sense Valve Standard End Standard Config. T ports
Cover L - Left-side end cover for 12 Design Level
Z - None
Mid-inlet Config. A- Initial Release
7 Seal Material
Blank - Buna-N
V - Viton®
Transition Plates
1-6 7 8-9 11
1-6 Product Series 7 Seal Material 8-9 Special Features 11 Design Level
SLV20T - Sectional Load Blank - Buna-N 00 - No Special Features A- Initial Release
Sense Valve Standard V - Viton®
Transition Plate
Note: A standard transition plate can be used to transition from a pre to a post-compensated work section,
or from a post to a pre-compensated work section in an assembly.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
20 Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com
SLV20
Tie Rod kits
Standard Sections
Approximate
Tie Rod Kit Description
Length (mm)
SLV20/1 1 Section 120
Note: Please contact us to confirm the tie rod kit needed if any doubt,
or to request a tie rod length that is not listed above.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Electro-hydraulic Proportional Load Sensing DCV Solution (SLV20) E-VLSC-CC002-E—December 2020 www.eaton.com 21
Eaton
Hydraulics Group USA
14615 Lone Oak Road
Eden Prairie, MN 55344
USA
Tel: 1-800-386-1911
Eaton
Hydraulics Group Europe
Route de la Longeraie 7
1110 Morges
Switzerland
Tel: +49 7221 682 456
Eaton
Hydraulics Group Asia Pacific
Eaton Building
No.7 Lane 280 Linhong Road
Changning District, Shanghai
200335 China
Tel: (+86 21) 5200 0099
Fax: (+86 21) 2230 7240