Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 2

Critical force 21.

18 kN
Ag 120.2496208 mm^2 BRACING SYSTEM
Pu 23.53333333 kN
kL/r 50 Maximum Tension
Fy 248 Mpa Maximum Compression
E 200000 Mpa
Cc 133.755012
Fe 789.5683521 Mpa
Fcr 217.4489031 Mpa

FIRST ITERATION 2ND ITERATION


HSS6X.500 HSS7.5X.500
Ag (trial) 5220 mm^2 Ag (trial) 6650
rx 49.8 rx 78.2
ry 49.8 ry 48.8
r 49.8 r 63.2
k 1 pinned-pinned k 1
L 4610 mm L 4610
kL/r 92.57028112 Long Column kL/r 72.94303797
Fe 230.3491297 Mpa Fe 370.9898663
Fcr 202.0161868 Mpa Fcr 325.3581127
Ag 129.4359059 mm^2 Ag 80.36728493
Ag/Ag(trial) 0.024796151 Fail Ag/Ag(trial) 0.012085306

TENSION

Critical force 7.7 kN SECTION Ag


Ag 43.71681211 mm^2 HSS7.5X.500 6650
Pu 8.555555556 kN
kL/r 50 An
Fy 248 Mpa HSS7.5X.500 6490
E 200000 Mpa
Cc 133.755012 Av
Fe 789.5683521 Mpa HSS7.5X.500 320
Fcr 217.4489031 Mpa
BRACING SYSTEM

7.7 KN
21.18 KN

2ND ITERATION Considering Local Buckling


HSS7.5X.500 b/t 5.6
mm^2 1.40 √(E/Fy) 39.7573

Qs 1
Qa 1
Q 1
mm
Long Column
Mpa
Mpa
mm^2
Pass

d t h l
92.0165364078046 4 40 50

1.3D U Rupture Yield


119.621497330146 1 1058.43254 1484.28

At R Pu > Fcr
368.066145631219 926.7816 695.086206 passed