DCU 2.0 - Datasheet - EN

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

CoreShield Data Capture Unit

Data Sheet

Product designation
Siemens code A2V00002748719
Version 2.0

Transmission rate
Transfer rate 200 Mbit/s

Processor
Processor type ARM Cortex A9

Memory
Type of memory DDR3
Main memory 4 GB

Interfaces
Number of communication connections
• Ethernet ports 9
- 8x 10/100 Mbits/s Capture (CAP)
- 1x 10/100/1000 Mbits/s Outbound (ETH O)
• USB 3.0 ports 2 (local storage)
• Serial ports 1 (open network)
• Digital I/O 8 (open network)
• SD Card slot 1 (open network)
Type of communication connections
• Ethernet ports RJ45 socket
• USB ports USB 3.0 type A
• Serial ports RS-485 interface 5-pole M12 socket
• SD Card slot Interface for recording a microSD card

Electrical Interfaces
Number of electrical connections
• Power supply 1
Type of electrical connection
• Power supply 3 pin socket, 3.5 mm spacing

Standards, Approvals, Certificates


IEC 62443-4-2 Compliant with Security level 3 (SL 3)
UL approval Yes
RoHS Yes
CE Yes
EMC CE, EN 61000-6-2, EN 61000-6-4, EN 50121-4

Design, dimensions and weight


Design Compact for indoor use acc. to EN 50125-3
Width 60.6 mm
Height 167.0 mm
Depth 110.5 mm (excluding mounting rail)
Weight 0.795 Kg
Housing material Aluminum
Cooling Fan
Mounting type 35 mm DIN rail according to EN 60715 or Simatic Profile
rail (122 mm)

Design, dimensions and weight


Permitted ambient conditions
Ambient temperature
• Operation 0 °C to +70 °C
• Storage 0 °C to +70 °C
Transport 0 °C to +70 °C
Operating altitude Up to 2.000m above sea level

Power supply voltage, current consumption


Type of voltage DC
Supply Voltage

Subject to change without notice S25140 D328 A1


FRG_YYYY-MM-DD CoreShield Data Capture Unit
© Copyright Siemens Mobility GmbH Page 2 of 3
• Minimum 16.8 V
• Typical 24 V - 110 V
• Maximum 143 V
Consumed current* 0.23 A
Power consumption
• Minimum 12.5 W
• Maximum 15.3 W
Electrical isolation/protection of power supply 3.1 kV

Capture port connection specifications


Ethernet conformity IEEE 802.3 (100Base-T)
Ethernet cable length outbound (ETH O)
• Maximum** 100 m
Capture port cable length (CAP)
• Maximum** 50 m
Electrical isolation/protection of capture ports 1.5 kV

*60 V voltage supply and at all capture ports in TAP mode.


** (with (S)FTP Cat 6 cables)

Subject to change without notice S25140 D328 A1


FRG_YYYY-MM-DD CoreShield Data Capture Unit
© Copyright Siemens Mobility GmbH Page 3 of 3

You might also like