Professional Documents
Culture Documents
Isolated Footing Design As Per Is 456 2000
Isolated Footing Design As Per Is 456 2000
BUILDING DESIGN
Contents [hide]
Follow our previous articles for the complete column, beam, one way slab and two way slab design by using manual method
Fitness
Basic formulas usedApparel & Accessories
in the design as per IS456-2000 code
Decathlon Sports - OMR Perungudi
For the design of RCC footing as per the IS456 code the following 8 basic formulas are used which are given as per IS 456 standards.
https://civilbasics123.com/isolated-footing-design-as-per-is-456-2000-code/ 1/10
1/18/24, 12:39 PM isolated-footing-design-as-per-IS-456-2000-code | foundation-design |
1. Load calculations
2. Size of footings
3. Calculation of net upward pressure at ultimate load
4. Calculation of one way shear to determine the depth
5. Check for punching shear / Two way shear
6. Reinforcement design
Consider self weight of footing and back fill is 10% column load
Now the total load on the column = Factor load + 10% column load
= 1800+120 =1920 kN
Let us consider the square footing which is having length and width as B
https://civilbasics123.com/isolated-footing-design-as-per-is-456-2000-code/ 2/10
1/18/24, 12:39 PM isolated-footing-design-as-per-IS-456-2000-code | foundation-design |
Upward pressure
Step 4: Calculation and check for one way shear to determine the depth
Pt =0.15%
310(2700-2d) = 1116d
https://civilbasics123.com/isolated-footing-design-as-per-is-456-2000-code/ 3/10
1/18/24, 12:39 PM isolated-footing-design-as-per-IS-456-2000-code | foundation-design |
= 1741.5 kN
Vc2 = Ksb0d
Where b0 = 4(C1+d)
= 4(400+550)
= 3800
Vc2 = 1X1.118X3800X550
= 2336.62 kN
Mu = (quB/8) (B-C)2
Mu = ((0.2X3100)/8) (3100-400)2
Mu = 564.975 kN.m
Mu = 0.87fyAstd(1-(Astfy/bdfck))
Spacing = (A/Ast)XB
= (201/2951.4)X3100
= 211.12 mm
https://civilbasics123.com/isolated-footing-design-as-per-is-456-2000-code/ 4/10
1/18/24, 12:39 PM isolated-footing-design-as-per-IS-456-2000-code | foundation-design |
So the final reinforcement for isolated footing as per IS 456-2000 code is obtained as use 16mm diameter bars at 210 C/C distance in both X direction and Y
direction.
The complete concepts of isolated footing design as per IS 456-2000code is explained in my YouTube channel Civil engineering by shravan. See below for
complete details.
What is load combination ? different load combinations used as per IS 456-2000 code
How to apply complete G+1 building gravity loads in staad pro software
https://civilbasics123.com/isolated-footing-design-as-per-is-456-2000-code/ 5/10