Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

TECHNICAL SPECIFICATION

CONSIGNEE : GE 862 EWS, PIN 913862, C/O 56 APO

NAME OF WORKS : PROVN OF GUARD ROOM WITH SENTRY POST FOR 25 ARTY BDE
CAMP AT RAJOURI.

Ser Description of items Unit Qty Remarks


No
1 Mobilisation of manual drilling equipment/rig and shifting of Each 1.00
entire arrangement from one bore to another hole location Job
and setting of boring/ drilling rig as required/ directed by
Engineer-in charge.
2 Boring 150mm dia bores holes to given depth or refusal Mtr 16.00
strata through any type of soil as under :-
(a) 08 Mtr depth- 02 No
3 Collection of undisturbed soil sample at 1.50 M intervals or at Each 1.00
any change of strata in 1.50 mm bore thin walled tube incl Job
waxing sealing, packing and transporting to the slab.
4 Carrying out standard penetration test incl collecting of Each 1.00
disturbed soil samples in bore holes at every 1.5m depth or Job
any change of strata and submit the report with all requisite
data.
5 Conducting necessary tests as per relevant IS codes/NBC
2005/SP 36 on all collected samples which incl the
determination of :-

(a) Atterberg Limits.


(b) Natural moisture content.
(c) Wet and dry density.
(d) Soil particle size distribution using sieve/
hydrometer analysis.
(e) Shrinkage limit.
(f) Consolidation test.
(g) Specific gravity test for sand rock.
(h) Crushing str of rock samples.
(j) Permeability test.
(k) Chemical analysis of ground water sample
(min 02 samples).
(l) Free soil index.
(m) Chemical analysis of soil.
(n) 'N' value of an interval of 1.5 mtr of 6 mtr
depth.
(o) Tri axial shear test C&C determination

6. Maintaining photographic record (min three photographs per


hole duly annotated)
7.
Submission of report of soil investigation in pentaplicate
alongwith photographic record duly annotated
Note: ltems 6 and 7 be executed with no extra cost as obligation but will be part of entire work