DSP Board & PWR Board Voltage Test Instructions

Please remove the DSP board and PWR board from the machine, remove the heat sink
on the DSP board, and remove the shield of the PWR board.As the figure shown.

Figure 1
Figure 2
Please find an ATX power supply and connect the 12V power cable to the PWR board,
as picture below:

Figure 3
Please assemble the DSP board and the PWR board, and use the ATX power supply to
supply power to the PWR board. As the figure shown.

Figure 4
Short-circuit the green and black cable in the 20 pins power cable of the ATX to start
up the ATX, as picture below:
Figure 5

Figure 6
Please measure the voltage on the DSP board and the PWR board separately. Please
refer to picture 1 and picture 2 for the specific location of the testing points. The
voltage measurement table is as follows.

DSP board voltage test point


Test point Theoretical value Measurements
TP62 5V
TP63 3.3V
TP59 1.8V
TP61 1.8V
VCC2V5 2.5V
VCC1V 1.0V
1V5_DDR 1.5V
TP64 3.3V
VCC1V2 1.2V

PWR board voltage test point


Test point Theoretical value Measurements
TP45 1.6V
TP23 4V
TP17 3V
TP22 4V
TP24 5.7V
TP36 -7V
TP37 -75V
TP38 75V
TP44 3.3V
TP16 3.3V
TP27 5V
TP32 -5V
TP29 -12V
TP25 50V
TP31 -50V
TP35 -75V
TP28 75V
TP53 5V
TP12 12V

Please tell us the test results.