D-MET-TEST-CAL Required specifications

S-MET-TEST
Stationary calibration benches for energy meters not ok
Sl. No.

1 GENERAL
1.01 Manufacturer
1.01.1 name
1.01.2 country of manufacturing
1.02 Applicable standards
1.03 Type test
1.03.1 date
1.03.2 in the year
1.03.3 testing laboratory
1.03.3.1 name
1.03.3.2 country
1.04 Applicable type of meters to be calibrated
1.04.1 micro-processor based
1.04.2 electro-mechanical
1.04.3 Numbers of meters to be tested
2 DESIGN DATA

2.01 Measurements

2.02 Auxiliary voltage range


2.03 Voltage input range to Meter
2.04 Current input range to Meter
2.05 Maximum power consumption
2.06 Frequency range
2.07 Power factor
2.08 Applied software is MS Windows based
2.09 Microprocessor resolution (minimum)
2.10 Class of accuracy (minimum)
2.11 Applicable safety standards
2.12 Protection class
2.13 Communication port for data transfer
2.13.1 applicable standards
2.13.1.1 optical port
2.13.1.2 protocol
2.13.2 type
2.14 Electronic signals for calibration are provided for
2.14.1 three phase voltages
2.14.2 three phase currents
2.14.3 phase angle
2.14.3.1 harmonics
2.14.3.2 ripple control signals
2.14.4 Calibration bench is fully automatic
2.14.4.1 Number of meters accommodated on suspension rack (minimum)
2.14.4.2 Bench provided with a control unit
2.14.5 Scanning heads are adjustable
2.14.5.1 Bench provided with central data storage
2.14.5.2 Compatible hardware and software is included
2.15 Number of Meters that Bench can store its data
2.16 Set is equipped with an interface for data transfer
2.17 Barcode reader included
2.17.1 Bench equipped with optical sensors
2.17.2 Error curves generated are tabular and graphical
2.17.3 Type of protections provided for output signals
2.17.4 Data can be exported from the database
2.17.5 Automatic test sequences for
2.17.6 meter starting test
2.18 no load test
2.19 load tests with pre set values
2.20 Signals are protected against overload /short circuit
2.21 Analogue as well as binary inputs provided
2.27 Label printer (for calibration date, etc.)
2.27.1 printer included
2.27.2 stamp in barcode
2.27.2.1 color
2.27.2.2 height
2.27.2.3 width
2.28 Materials
2.28.1 housing frame
2.28.1.1 galvanised mild steel sheet
2.28.1.2 aluminium die-cast alloy
2.28.1.2.1 thickness
2.29 Dimensions
2.29.1 length
2.29.2 width
2.29.3 depth
2.29.4 Weight
3 OTHER PERFORMANCE
3.01 First commercial operation of the equipment
3.02 Reference list attached
4 SUPPORTING DOCUMENTS
4.01 Type test reports enclosed ?
4.02 List of minimum testing facilities enclosed ?
4.03 Technical literature enclosed ?
4.04 Relevant drawing enclosed ?
4.05 Quality assurance plan (QAP) enclosed ?
Required or maximum allowed Manufacturer guarantee/note
0 All data
not complete

0
0
IEC 60736 0
yes 0
dd-mm-yy 0
year 0
0
0
0
0
yes 0
yes 0
No. 0

active, reactive, apparent power, current,


voltage, power factor, frequency, voltage
sequence indication 0
Vac 86 to 260 0
Vac 30 to 480 0
A 0.01 to 120 0
VA 25 0
Hz 45 to 55 0
0-lag-unity-0-lead 0
yes 0
bit 16 0
0.1 0
IEC 61010 0
IP 68 0

0
IEC 62056-21 0
MODBUS, DNP 0
RS 232 0

yes 0
yes 0
yes 0
yes 0
yes 0
yes 0
No. 0
yes 0
yes 0
yes 0
yes 0
No. 0
yes 0
yes 0
yes 0
yes 0
0
yes 0
0
yes 0
yes 0
yes 0
yes 0
yes 0

yes 0
0
black/white 0
mm 0
mm 0

0
yes/no 0
yes/no 0
mm 2 0

mm 0
mm 0
mm 0
kg 0

dd-mm-yy 0
yes/no 0

yes 0
yes 0
yes 0
yes 0
yes 0

You might also like