DICHIARAZIONE DI CONFORMITÀ

COMPLIANCE DECLARATION
(UNI CEI EN ISO/IEC 17050-1,2)

Doc. N. 318/23.1 - Ref. PO 1582 Date 02.11.2023


Cliente / Customer Destinazione / Destination
Proteccion Catodica de Colombia
Km 4.3 Via Suba - Cota
Bogotà
Colombia

Cod. Description Quantity

HISEO® Ti MMO Ribbon Anode W=6,35mm x 2.000 m


thick. 0,6mm x 25m coil length, Ti Gr1 ASTM
B265
Art. T0.6SR6JJ10A1

We certify that, subject to exceptions or concessions listed hereafter, the products detailed here were manufactured in accordance to the market
technical specifications; the inspection operation and the test effected following the International Standards (ISO) have confirmed the parameters
constancy that guarantee the products quality and their correspondence to the specifications fixed.

Certifichiamo che, fatte salve le eccezioni e le concessioni di seguito indicate, i prodotti sono stati fabbricati conformemente alle specifiche tecniche
contrattuali. I controlli e le prove , effettuati secondo le norme internazionali (ISO) hanno confermato la costanza dei parametri che garantiscono la
qualità dei prodotti e la loro corrispondenza alle specifiche stabilite e a quanto in precedenza benestariato.

WIR BESCHEINIGEN, DASS DIE VORSTEHENDE AUFGEFUHRTE LIEFERUNG NACH UNSEREN PRODUKTSPEZIFIKAZIONEN UND DER
KUNDENBESTELLUNG HERGESTELLT WORDEN SIND. DIE VOLLSTAENDIGE UEBER EINSTIMMUNG ALLER EIGENCHAFTEN DER (DES) OBENGENANNTEN
PRODUKTE(S) MIT DEN ANFORDERUNGEN DIESER SPEZIFIKATIONEN, UND/ODER SONSTIGER VEREINBARTER VORSCHRIFTEN WURDE DURCH EINE
VORSCHRIFTSMAESSIGE QUALITAETSSICHERUNG IN UNSERER PRODUKTION UEBERWACHT UND BESTAETIGT.

Supplier’s Inspection
Substrate: Titanium Coil thickness
Ti grade 1 as per ASTM B265 Certificate
0,6mm
Iridium load measurement to fulfil the designed coating Passed
X- ray test with Niton detector
amount - Lab test report n° 299/22/xr Form M-Cq 006
Current output
Reference NACE TM0294-2016 (B) Passed
Accelerated Life Test at high
Lab test report n° 299/22/lt Form M-Cq 10
current density in sulfuric acid
ASTM D 3359-09e2 Tape test
Passed
Coating Adherence Report n° 299/22/ca
Form M-Cq 009
Il Controllo Qualità Quality Responsible
Quality Control DR. LUISA GIANNITELLI