VR1056A - 8116610659 - Rev. 00 D-30.09.2022
VR1056A - 8116610659 - Rev. 00 D-30.09.2022
General:
Project Name & Location: Third Party Inspection services Inspection Location: Heatreaters & EngineersMumbai INDIA
At Achhad Works [ TPI NRB Ashok Silk Mill Lane Off. L.B.S. Marg,
BARC ] Ghatkopar West, Mumbai – 400086
Contact No. Mr. Paresh: +9198214
54224
TUV India Client Name: TEMA INDIA LIMITED. End User Name: TEMA INDIA LIMITED. (31026)
Vendor Name & Location: TEMA INDIA LIMITED. P.O. Number: DPS/NRBPSU/03/N1/2605/TPT/MPO/522,
(Client PO on Vendor)
DT04.10.2018 (TEMA WO No. 17185)
Dated 04/10/2018
Stages Of Inspection:
Item Description:
Reference Documents:
Sr.
Document Name Client Document Number Vendor Document Number Approval Status
No.
1 PR/MR/ARM
2 QAP/ITP/QCP
3 Drawing(s)
4 Datasheet(s)
6 Others(Specify)
Stages Witnessed:
1
Disclaimer: Unloading
This IVR shall notwitnessed
be consideredfor solution
as final annealed
acceptance of inspectedHeat Treatment
item(s).The for Rate
final acceptance of Heating
will be given kept as
through Inspection 100Note.
Release to 160 deg
The inspectionMaximum
by TUV India for
Pvt. Soaking
Ltd., review oftempbetween 1050and
Test Certificates / Reports deg toof1070
issue deg
Inspection . Report does not relieve the Client / Supplier / Manufacturer / Stockiest from their responsibility towards the Client
Visit
/ End User toSoaking
supply the genuine
period material
kept / item(s)
for 30andmin.
document(s) in full compliance with applicable Order, Specification, Technical, Quality, Quantity, Warranty, Guarantee requirements. Supplier / Manufacturer /
stockiest is wholly legally responsible for genuineness of the material / item(s) supplied and document(s) submitted. TÜV India’s responsibility is only limited to correctness of inspection results including review of the
Cooling medium used as water.
documents, within its agreed scope against written requirements and neither TUV India nor any of its group companies, associates or employees are in any way/ legally responsible for genuineness of the material /
item(s) and document(s). If the calibration certificate(s) for the measuring instrument(s) / equipment(s) used during inspection do not have traceability to NABL / Other certifying bodies, then the scope of review is limited
only to technical content in the calibration certificate.
Documents Reviewed:
Copyright: This document is the property of TUV India Pvt. Ltd. and should not be reproduced, except in full without the consent of TUV India Pvt. Ltd.
TUV India Pvt. Ltd. (TÜV NORD GROUP) : (REGD. & HEAD OFFICE), 801, Raheja Plaza I, LBS Marg, Ghatkopar (West), Mumbai – 400086, Maharashtra, India.
Tel: +191 22 66477000,
Graph Found in order.
Email: inspection@tuvnord.com; Website: www.tuvnord.com/in.
Form No. : F / INSP / VR / 11 – R12; Revision Date: 14.03.2020 / TIIMES Page 1 of 4
2 Calibration Certifiacte reviewed NABL Traceability not found in calibration Cirtificate of Roll Thermocouple
5 Procedure(s) HT1718501 Approved
6 Others(Specify)
TUV INDIA PRIVATE LIMITED
Inspection Activities Carried Out:
INSPECTION VISIT REPORT
Stages Witnessed: IVR010102105821/1648Rev.0
IVR-8116610659-1056-A-Rev.00
1 Unloading witnessed for solution annealed Heat Treatment for Rate of Heating kept as 100 to 160 deg
Maximum for Soaking tempbetween 1050 deg to 1070 deg .
Soaking period kept for 30 min.
Cooling medium used as water.
Documents Reviewed:
2 Calibration Certifiacte reviewed NABL Traceability not found in calibration Cirtificate of Roll Thermocouple
Details of Equipment(s) / Instrument(s) used for measuring / testing During Inspection:(Refer Notes)
NABL / OTHER NONNABL
Sr. Detail of Range ID Validity till Calibration Certificate CERT. BODIES /
Equipment(s)/ Date Number NABL Traceability
No. Instrument(s) Please tick or Write Yes (whichever is applicable)
.
Areas of Concerns:
Attachments:
Inspection Photos –
4 Others (Specify) :
Refer Page Nos.
Authorised Signature:
Distribution List: TUVI Client / End User TUVI Executing Branch / TUV Originating Branch Vendor / Sub Vendor
Revision Number (If Applicable) [0] :
Disclaimer: This IVR shall not be considered as final acceptance of inspected item(s).The final acceptance will be given through Inspection Release Note.
This Document Supersedes IVR No. :
The inspection by TUV India Pvt. Ltd., review of Test Certificates / Reports and issue of Inspection Visit Report does not relieve the Client / Supplier / Manufacturer / Stockiest from their responsibility towards the Client
/ End User to supply the genuine material / item(s) and document(s) in full compliance with applicable Order, Specification, Technical, Quality, Quantity, Warranty, Guarantee requirements. Supplier / Manufacturer /
stockiest is wholly legally responsible for genuineness of the material / item(s) supplied and document(s) submitted. TÜV India’s responsibility is only limited to correctness of inspection results including review of the
documents, within its agreed scope against written requirements and neither TUV India nor any of its group companies, associates or employees are in any way/ legally responsible for genuineness of the material /
item(s) and document(s). If the calibration certificate(s) for the measuring instrument(s) / equipment(s) used during inspection do not have traceability to NABL / Other certifying bodies, then the scope of review is limited
only to technical content in the calibration certificate.
Copyright: This document is the property of TUV India Pvt. Ltd. and should not be reproduced, except in full without the consent of TUV India Pvt. Ltd.
TUV India Pvt. Ltd. (TÜV NORD GROUP) : (REGD. & HEAD OFFICE), 801, Raheja Plaza I, LBS Marg, Ghatkopar (West), Mumbai – 400086, Maharashtra, India.
Tel: + 91 22 66477000, Email: inspection@tuvnord.com; Website: www.tuvnord.com/in.
Form No. : F / INSP / VR / 11 – R12; Revision Date: 14.03.2020 / TIIMES Page 2 of 4
TUV INDIA PRIVATE LIMITED
Name: Tausif Mapari INSPECTION VISIT
Date:02/10/2022 REPORT
Name:
IVR010102105821/1648Rev.0
IVR-8116610659-1056-A-Rev.00
Distribution List: TUVI Client / End User TUVI Executing Branch / TUV Originating Branch Vendor / Sub Vendor
Revision Number (If Applicable) [0] :
This Document Supersedes IVR No. :
Disclaimer: This IVR shall not be considered as final acceptance of inspected item(s).The final acceptance will be given through Inspection Release Note.
The inspection by TUV India Pvt. Ltd., review of Test Certificates / Reports and issue of Inspection Visit Report does not relieve the Client / Supplier / Manufacturer / Stockiest from their responsibility towards the Client
/ End User to supply the genuine material / item(s) and document(s) in full compliance with applicable Order, Specification, Technical, Quality, Quantity, Warranty, Guarantee requirements. Supplier / Manufacturer /
stockiest is wholly legally responsible for genuineness of the material / item(s) supplied and document(s) submitted. TÜV India’s responsibility is only limited to correctness of inspection results including review of the
documents, within its agreed scope against written requirements and neither TUV India nor any of its group companies, associates or employees are in any way/ legally responsible for genuineness of the material /
item(s) and document(s). If the calibration certificate(s) for the measuring instrument(s) / equipment(s) used during inspection do not have traceability to NABL / Other certifying bodies, then the scope of review is limited
only to technical content in the calibration certificate.
Copyright: This document is the property of TUV India Pvt. Ltd. and should not be reproduced, except in full without the consent of TUV India Pvt. Ltd.
TUV India Pvt. Ltd. (TÜV NORD GROUP) : (REGD. & HEAD OFFICE), 801, Raheja Plaza I, LBS Marg, Ghatkopar (West), Mumbai – 400086, Maharashtra, India.
Tel: + 91 22 66477000, Email: inspection@tuvnord.com; Website: www.tuvnord.com/in.
Form No. : F / INSP / VR / 11 – R12; Revision Date: 14.03.2020 / TIIMES Page 3 of 4
TUV INDIA PRIVATE LIMITED
INSPECTION VISIT REPORT
IVR010102105821/1648Rev.0
IVR-8116610659-1056-A-Rev.00
Inspection Pictures :
Unloading witnessed Immediate Queching in water after rempval from the Furnance
Disclaimer: This IVR shall not be considered as final acceptance of inspected item(s).The final acceptance will be given through Inspection Release Note.
The inspection by TUV India Pvt. Ltd., review of Test Certificates / Reports and issue of Inspection Visit Report does not relieve the Client / Supplier / Manufacturer / Stockiest from their responsibility towards the Client
/ End User to supply the genuine material / item(s) and document(s) in full compliance with applicable Order, Specification, Technical, Quality, Quantity, Warranty, Guarantee requirements. Supplier / Manufacturer /
stockiest is wholly legally responsible for genuineness of the material / item(s) supplied and document(s) submitted. TÜV India’s responsibility is only limited to correctness of inspection results including review of the
documents, within its agreed scope against written requirements and neither TUV India nor any of its group companies, associates or employees are in any way/ legally responsible for genuineness of the material /
item(s) and document(s). If the calibration certificate(s) for the measuring instrument(s) / equipment(s) used during inspection do not have traceability to NABL / Other certifying bodies, then the scope of review is limited
only to technical content in the calibration certificate.
Copyright: This document is the property of TUV India Pvt. Ltd. and should not be reproduced, except in full without the consent of TUV India Pvt. Ltd.
TUV India Pvt. Ltd. (TÜV NORD GROUP) : (REGD. & HEAD OFFICE), 801, Raheja Plaza I, LBS Marg, Ghatkopar (West), Mumbai – 400086, Maharashtra, India.
Tel: + 91 22 66477000, Email: inspection@tuvnord.com; Website: www.tuvnord.com/in.
Form No. : F / INSP / VR / 11 – R12; Revision Date: 14.03.2020 / TIIMES Page 4 of 4