IMPORTANT: Keep a copy of your bill of sale. The date on the bill establishes the warranty period should
service be required. If service is performed, it is in your interest to obtain and keep all receipts. Keating
commercial hot plates are not intended for household use.
The Owner’s Guide provides specific operating instructions for your model. Use the Electric Hot Plate
only as instructed in this Owner’s Guide.
CONTENTS:
SECTION I: INTRODUCTION SECTION IV: MAINTENANCE
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 WARRANTY REPAIRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
RATINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 PREVENTIVE MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
OPTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
SECTION V: ORDERING PARTS
STANDARD FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
ORDERING PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
MODEL VARIATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
WARNING AND OPERATING PLATES . . . . . . . . . . . . . . . . . . . . . . .3
SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
HOT PLATE PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
SECTION II: INSTALLATION HOT PLATE ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
DAMAGE DURING SHIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
SECTION VI: WIRING DIAGRAMS
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
HOT PLATE WIRING AND LADDER DIAGRAMS . . . . . . . . . . .5-11
POSITIONING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
RESTRAINING DEVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
ELECTRICAL CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
*AS CONTINUOUS PRODUCT IMPROVEMENT OCCURS, SPECIFICATIONS MAY BE CHANGED WITHOUT NOTICE.
1-800-KEATING
www.keatingofchicago.com
p a r t # 0 374 3 0 electricHotPlate
05/11
POST THIS LABEL IN A
PROMINENT LOCATION ON
YOUR UNIT.
INSTALLER:
WARNING
Gas Burns Shock
i
Clearances: Combustible Noncombustible
I INTRODUCTION Construction Construction
Back 6" 0"
Right Side 6" 0"
Left Side 6" 0"
GENERAL
You must install this appliance at least 16" away from
Keating MG-2 and MG-4 Hot Plates are designed to
any open flame.
give maximum production efficiency; delivering high
quality food products. The following design features are Adequate clearance for servicing and proper
incorporated in all Keating Hot Plates. operation must be maintained. Your hot plate is
designed to be serviced from the front.
STANDARD FEATURES Keating commercial hot plates are not intended for
other than household use. Installation in household
Highly polished stainless steel front voids warranty.
Infinite controls ALWAYS instruct new employees on proper hot plate
12" working height operation.
Heating elements with pans A hot plate should be operated ONLY by properly
Easy access for servicing trained personnel.
100% factory testing ALWAYS turn hot plate off each night.
ALWAYS disconnect electrical supply before
OPTIONS servicing.
24" or 30" depth NEVER leave a hot plate unattended during
operation.
MODEL VARIATIONS NEVER introduce objects into hot plate, while
operational, which are not designed or made for
MG-2 Model: The MG-2 model has two elements
cooking.
MG-4 Model: The MG-4 model has four elements THIS HOT PLATE MAY NOT BE ALTERED,
MODIFIED OR CHANGED IN ANY WAY.
SAFETY PRECAUTIONS CAUTION Safe operation of this equipment is
possible only when the operating
instructions and the safety precautions
WARNING are read completely and the instructions
contained therein are strictly observed.
THIS SYMBOL WARNS YOU THAT SERIOUS BURNS
Before operating this equipment, ask for
OR OTHER INJURIES MAY RESULT IF SAFETY Read all operating and
safety instructions
before using equipment. a practical demonstration.
INSTRUCTIONS ARE NOT FOLLOWED.
WARNING Periodically inspect cable and plug, if
This service manual should be retained in a safe
provided, before using machine.
place for future reference.
Servicing should be performed by
The installation of your new hot plate must conform qualified and licensed service
to local codes or in the absence of local codes, with the companies.
current National Electrical Code ANSI/NFPA 70 or Plug into a
properly grounded
Canadian Electrical Code CAN 22.2 as applicable. three-prong receptacle.
1
IF DISCONNECTION OF THE RESTRAINT IS
DAMAGE DURING SHIPMENT NECESSARY, IT MUST BE RECONNECTED WHEN
The hot plate has been assembled, tested and THE HOT PLATE IS RETURNED TO ITS ORIGINALLY
inspected at the factory. Upon arrival, the complete hot INSTALLED POSITION.
plate should be checked for any damage that may have
occurred during shipment. ELECTRICAL CONNECTION
The carrier is responsible for all damage in transit The Keating Electric Hot Plate is equipped with a three
whether visible or concealed. Do not pay for the freight wire terminal block for customer connections. Compare
bill until the hot plate has been thoroughly checked for the hot plate terminal connections to the appropriate
damage. If concealed damage is found later, contact the wiring diagram for the hot plate (see pages 5-11 Wiring
carrier immediately to file a claim. Diagram) to see if the hot plate is connected three
phase or single phase. All wires, cords, plugs,
What to do if equipment arrives damaged: receptacles and circuit breakers must be sized
VISIBLE LOSS OR DAMAGE – Be certain to note this adequately for the full load rating of the griddle as
on the freight or express receipt and have it signed by specified by local codes or, in the absence of local
the delivery person. codes, by the current National Electrical Code
ANSI/NFPA 70 or the Canadian Electrical Code CAN
FILE CLAIM FOR DAMAGES IMMEDIATELY – 22.2 as applicable.
Regardless of extent of damage.
The Electric Hot Plate is also equipped with a grounding
CONCEALED LOSS OR DAMAGE – If damage is lug next to the terminal block. For proper grounding
noticed when equipment is unpacked, notify the freight procedures, see local codes or, in the absence of local
company immediately, and file a “concealed damage codes, the current National Electrical Code ANSI/NFPA
claim”. This MUST be done immediately. Be sure to 70 or the Canadian Electrical Code CAN 22.2 as
retain the shipping container for inspection. applicable.
Keating does not assume responsibility for Loss OR NOTE: The connections to the hot plate can be
Damage incurred in transit. changed in the field from three phase to single phase or
from single phase to three phase. This can be done by
INSTALLATION simply changing the wiring at the terminal block. To
change the connections for your hot plate, see the
Installation must conform with local codes or, in wiring diagram for your griddle on pages 5-11.
absence of local codes, with the current National
Electrical Code ANSI/NFPA 70 or Canadian Electrical NOTE: For hot plates rated at 208-240 volts, the
Code CAN22.2 as applicable. amperage ratings marked on the nameplates of the
griddles are listed at 240 volts as required by UL.
POSITIONING NOTE: A hole has been punched in the rear of the hot
The hot plate must be placed under an exhaust hood plate cabinet for a cord or conduit exit. If a cord is used,
with a fire retardant system. Your ventilation hood, when the National Electrical Code, UL standards and most
installed, must conform to the current ANSI/NFPA 96 local codes require a bushing or strain relief (not
standard. ALL connections and placement must comply provided by Keating) to protect the cord.
with local and national codes. It is the responsibility of
the owner and local installer to comply with these
regulations when installing the hot plate.
NOTE: NOT FOR OUTDOOR INSTALLATION
III OPERATING
RESTRAINING DEVICES
LIGHTING
WARNING Hot plates must be restrained to
prevent tipping when installed in Keating hot plates are designed to provide maximum
order to avoid splashing, spilling, etc. efficiency and deliver high quality food products. Follow
of hot liquid. The restraining method lighting procedure below.
may be a manner of installation or by
separate means. Adequate means
must also be provided to limit the WARNING
Do not stand, sit or movement of the appliance. OPERATION OF THIS HOT PLATE SHOULD BE
lean on equipment.
LIMITED TO PERSONNEL WHO HAVE BEEN
THOROUGHLY TRAINED IN OPERATING
2
PROCEDURES.
1. Push in the red knob and rotate it fully V PARTS LISTS
counterclockwise to the desired setting.
NOTE: The left knob operates the back burner and the
right knob operates the front burner. ORDERING PARTS
Parts may be ordered by part number by calling Keating
SHUTDOWN at 1-800-KEATING or your service company. You may
1. Rotate the red knob fully clockwise for each burner. also order on-line at Keating’s part store,
www.keatingofchicago.com
WARRANTY REPAIRS
Keating’s warranty begins with the date of installation. In
the event that your hot plate, under warranty, needs
repairs other than routine maintenance or cleaning, you
are requested to contact Keating of Chicago (at 1-800-
KEATING) before calling a local service company.
PREVENTIVE MAINTENANCE
Preventive maintenance should be done in daily,
weekly, and monthly intervals as necessary. Following
preventive maintenance procedures will help keep your
hot plate working efficiently. Proper care and servicing
will lead to years of quality performance.
3
ELECTRIC PLATE PARTS LIST
PART
ITEM DESCRIPTION MG-2 MG-4 NUMBER
1
1
2
2
3 3
4
4
5 5
4
VI WIRING DIAGRAMS
5
MG-2 208- 240 VOLT 3 PHASE
6
MG-2 480 VOLT SINGLE PHASE WITH
RESISTORS FOR 240V HEATING ELEMENTS
7
MG-2 480 VOLT 3 PHASE WITHOUT RESISTORS
FOR 240V HEATING ELEMENTS
8
MG-4 208- 240 VOLT SINGLE PHASE
9
MG-4 208- 240 VOLT 3 PHASE
10
MG-4 480 VOLT 3 PHASE WITHOUT RESISTORS
FOR 240V HEATING ELEMENTS
11
SERVICE INFORMATION
If you have a service related question call 1-800-KEATING.
Please state the nature of the call; it will ensure speaking with the appropriate person.
Have your serial and model number available when ordering parts.
*As continuous product improvement occurs, specifications may be changed without notice.