Professional Documents
Culture Documents
2D 3D TEE Transcatheter Guiding With LAA Thrombus
2D 3D TEE Transcatheter Guiding With LAA Thrombus
Clinical Medicine
Article
Utilization of Two- and Three-Dimensional Transesophageal
Echocardiography in Successfully Guiding Transcatheter Mitral
Valve in Bioprosthetic Mitral Valve/Mitral Ring Implantation
without Complications in Patients with Thrombus in Left
Atrium/Left Atrial Appendage
Zeyad M. Elmarzouky 1,† , Ming-Chon Hsiung 2,† , Amr Darwish 1 , Subash Dulal 1 , Bhanu Maturi 3 ,
Wei-Hsian Yin 2,4 , Yung-Tsai Lee 2,5 , Tien-Ping Tsao 2,6 , Jeng Wei 2,6 and Navin C. Nanda 1, *
1. Introduction
Copyright: © 2022 by the authors.
Bioprosthetic valves and atrio-ventricular valve annuloplasty rings are increasingly
Licensee MDPI, Basel, Switzerland. used because the need for anticoagulants essential for mechanical valves to avoid throm-
This article is an open access article bosis can be obviated. However, these valves are prone to degeneration and significant
distributed under the terms and stenosis and/or regurgitation may occur within a decade of implantation [1]. Annuloplasty
conditions of the Creative Commons rings have also failed resulting in significant valvular or para-ring regurgitation. Repeat
Attribution (CC BY) license (https:// surgery in these patients who are often elderly and have other comorbidities such as chronic
creativecommons.org/licenses/by/ renal failure carries a high mortality [2]. Because of this, procedures requiring minimal, or
4.0/). no surgery have come into vogue. One such approach is transcatheter prosthetic mitral
2 patients and another patient with a fixed thrombus had mobile components. These were
detected by both 2D and 3DTEE. Areas of echolucencies within the thrombus consistent
with thrombus lysis/dissolution were noted in all patients by both 2D and 3DTEE [8,9].
The maximum echolucent area in each thrombus was found to be larger by 3DTEE than
2DTEE (Table 2). Left and right ventricular function and other associated echocardiographic
findings in each patient are also listed in Table 2. One patient with a previous successful
transcatheter aortic valve replacement was noted to have developed severe prosthetic aortic
valve stenosis with a mean pressure gradient of 41 mmHg.
Transcatheter
Pre Procedure Surgical
Case #. Age/Sex MVR/Date/Other Associated Comorbidities
MVR/Date/Other Interventions
Interventions
CKD, DM, HTN, PAD, CAD, Tissue MVR for severe MR, TVA
Case 1. 74/F Boston Lotus, 27 mm/1/6/2016
chronic AF for severe TR/2011
ESRD, chronic hepatitis B
Tissue MVR for severe MR,
Case 2. 56/F Boston Lotus, 27 mm/1/11/2016 with acute exacerbation, CAD,
31 mm/2003
HTN
Edwards SAPIEN, Pulmonary hypertension, Tissue MVR for severe MR, TVA
Case 3. 55/M
26 mm/3/14/2016 chronic AF for severe TR/09/20/2010
Edwards SAPIEN XT, 29 mm and
Tissue MVR for severe MR, tissue
Case 4. 67/M redo AVR for severe CAD, chronic AF
AVR for severe AR/2009
AS/11/14/2016
Cardiogenic shock, ESRD, Tissue MVR for severe MR,
Edwards SAPIEN XT,
Case 2. 58/F HTN, CAD, chronic hepatitis 31 mm/2003, transcatheter MVR
29 mm/9/21/2018
B with acute exacerbation for severe MS/1/11/2016
Edwards SAPIEN XT, Tissue MVR for severe
Case 5. 61/M HBV carrier, chronic AF, CAD
29 mm/11/4/2018 MR/11/13/2009
COPD, antithrombin III
Edwards SAPIEN, Tissue MVR for severe MR, TVA
Case 6. 64/F deficiency, obstructive sleep
26 mm/4/29/2020 for moderate TR/11/04/1998
apnea
CKD, hepatocellular
Edwards SAPIEN, carcinoma, COPD, CAD, Tissue MVR for severe MS, TVA
Case 7. 73/M
39 mm/5/12/202 idiopathic pulmonary fibrosis, for severe TR/05/18/2009
polyangiitis, chronic AF
Edwards SAPIEN, Pulmonary hypertension, MVA with Sorin ring for severe
Case 8. 58/F
26 mm/10/27/2020 chronic AF MS, TVA for severe TR/2016
DM, ESRD, HTN, CAD,
Edwards SAPIEN, Tissue MVR for severe MR, TVA
Case 9. 68/F severe pulmonary
29 mm/12/29/2020 for severe TR/09/30/2011
hypertension, liver cirrhosis
Edwards SAPIEN, CAD, chronic AF,
Case 10. 78/F Tissue MVR for severe MS/2011
26 mm/5/10/2021 adenocarcinoma of lung
Edwards SAPIEN, Tissue MVR for severe MR, TVA
Case 11. 67/F Stroke, chronic AF
29 mm/11/7/2016 for severe TR/03/13/2007
Edwards SAPIEN XT, Right breast cancer, hepatitis Tissue MVR for severe MR, TVA
Case 12. 74/F
29 mm/7/24/2018 C, chronic AF for severe TR/08/14/1996
AF = Atrial fibrillation, AS = aortic stenosis, AVR = Aortic valve replacement, CAD = Coronary artery dis-
ease, CKD = Chronic kidney disease, COPD = Chronic obstructive pulmonary disease, DM = Diabetes mellitus,
ESRD = End-stage renal disease, HTN = Hypertension, MR = Mitral regurgitation, MS = Mitral stenosis, MVA = Mi-
tral valve annuloplasty, MVR = Mitral valve replacement, PAD = Peripheral artery disease, TR = Tricuspid
regurgitation, TVA = Tricuspid valve annuloplasty.
J. Clin. Med. 2022, 11, 7084 4 of 16
J. Clin. Med. 2022, 11, x FOR PEER REVIEW 3 of 16
(A)
(B)
(C)
(D)
Figure 1. Cont.
J. Clin. Med. 2022, 11, 7084 5 of 16
J. Clin. Med. 2022, 11, x FOR PEER REVIEW 4 of 16
(E)
(F)
(G)
(H)
Figure 1. Cont.
J. Clin. Med. 2022, 11, 7084 6 of 16
J. Clin. Med. 2022, 11, x FOR PEER REVIEW 5 of 16
(I)
(J)
(K)
Figure 1. (A–K), Video S1. 78-year-old female with severe bioprosthetic mitral valve stenosis (Case
Figure 1. (A–K), Video S1. 78-year-old female with severe bioprosthetic mitral valve stenosis
10). Pre-procedure. Two-dimensional transthoracic echocardiography with color Doppler guided
(Case
continuous Pre-procedure.
10). Two-dimensional
wave Doppler in (A) transthoracic
shows a mean pressure gradientechocardiography
(PG) of 14 mmHg acrosswith mitral
color Doppler
guided continuous wave Doppler in (A) shows a mean pressure gradient (PG)
valve replacement (MVR) consistent with severe stenosis. Two-dimensional transesophageal echo- of 14 mmHg across
cardiography
mitral (B,C) using the
valve replacement sameconsistent
(MVR) technique with
as in severe
(A) shows a mean
stenosis. pressure gradienttransesophageal
Two-dimensional of 13.1
mmHg across MVR also
echocardiography consistent
(B,C) using thewith severe
same stenosis inas(B).
technique in Turbulent
(A) shows flow across pressure
a mean MVR as wellgradient of
as a thrombus (TH) in the left atrial appendage (LAA) and adjacent left atrium (LA) body are
13.1 mmHg across MVR also consistent with severe stenosis in (B). Turbulent
demonstrated in (C). Live/real-time three-dimensional transesophageal echocardiography (D–G,
flow across MVR as
well as a thrombus (TH) in the left atrial appendage (LAA) and adjacent left atrium
Video S1). The arrow in (D) points to the MVR orifice which measures 0.72 cm in multiplanar re-
2 (LA) body are
demonstrated in (C).
construction (MPR) Live/real-time
mode consistent withthree-dimensional transesophageal
severe stenosis. Viewing the LA body enechocardiography
face by cropping (D–G,
Video S1). The arrow in (D) points to the MVR orifice which measures 0.72 cm2 in multiplanar
reconstruction (MPR) mode consistent with severe stenosis. Viewing the LA body en face by cropping
J. Clin. Med. 2022, 11, 7084 7 of 16
the full volume dataset from below shows the TH (arrows) extending to near the MVR in (E).
Video S1 shows both fixed (left arrow) and mobile (right arrow) components of the TH. The right
upper panel in F shows the TH involving LAA almost completely and extending to the adjacent
LA body (arrow). The arrow in the right lower panel shows the TH adjacent to the aorta (AO).
The arrow in the left lower panel shows the TH adjacent to PA. The combined volume of the
TH in LAA and adjoining LA body measured 19.4 mL as shown in (G). During Procedure. Two-
dimensional transesophageal echocardiography (H). The lower arrow in H shows the catheter
deployment device passing through MVR and lodged in the left upper pulmonary vein (UPV).
The upper arrow points to the TH which was bypassed during the procedure. Live/real-time
three-dimensional transesophageal echocardiography (I). The vertical arrow in (I) points to the
catheter deployment device bypassing and avoiding the TH (horizontal arrow). Post-procedure.
Two-dimensional transesophageal echocardiography (J). Color Doppler directed continuous wave
Doppler examination in 4 chamber view in J shows a marked decrease in the mean pressure gradient
across the new MVR to 1.8 mmHg indicative of relief of stenosis. Live/real-time three-dimensional
transesophageal echocardiography (K). In (K), #1 and #2 represent the old and new prosthetic valve
rings, respectively, in full volume short-axis view. LV = left ventricle; PA = pulmonary artery;
RA = right atrium; RV = right ventricle; RVO = right ventricular outflow. PV = pulmonary valve.
1
Figure 2. (A,B). 56-year-old female with severe MVR stenosis (Case 2). Pre-procedure. Live/real-time
three-dimensional transesophageal echocardiography (A,B). A TH is noted in LAA and adjoining
LA body in A. During procedure. The arrow in B points to the catheter deployment device passing
through MVR avoiding the TH. Abbreviations as in Figure 1.
J. Clin. Med. 2022, 11, 7084 8 of 16
Figure 3. (A–C). The same patient (Case 2 above) returned 2 years and 8 months later with severe
stenosis of the new MVR. Pre-procedure. Two-dimensional transesophageal echocardiography (A). A
J. Clin. Med. 2022, 11, 7084 9 of 16
much smaller and poorly organized residual confined to LAA is noted in A. Live/real-time three-
dimensional transesophageal echocardiography
dimensional echocardiographywith withcolor
colorDoppler
Doppler(B).(B).The
The MVRMVR orifice (red
orifice arrow)
(red ar-
viewed
row) in MPR
viewed modemode
in MPR in B measures
in B measures 0.682 cm
0.68 cm by 2direct planimetry
by direct indicative
planimetry of severe
indicative restenosis.
of severe reste-
nosis. Post-procedure.
Post-procedure. Live/real-time
Live/real-time three-dimensional
three-dimensional transesophageal
transesophageal echocardiography
echocardiography (C). A(C). A
short-
short-axis
axis view view
in fullinvolume
full volume
modemode
showsshows
all theall the MVR
three three rings
MVRin rings
C. #in C. # 1 points
1 points to the outermost
to the outermost ring of
ring of the original
the original surgicallysurgically implanted
implanted MVR. # MVR.
2 shows # 2the
shows
middlethering
middle
of thering
firstoftranscatheter
the first transcatheter
implanted
implanted MVR. # 3 demonstrates the innermost ring of the second transcatheter implanted MVR.
MVR. # 3 demonstrates the innermost ring of the second transcatheter implanted MVR. Abbreviations
Abbreviations as in previous Figures.
as in previous Figures.
(A)
(B)
Figure
Figure4.4.(A,B).
(A,B).67-year-old
67-year-oldmale
malewith
withsevere
severeMVR
MVRstenosis
stenosis(Case
(Case4).
4).During
Duringprocedure.
procedure.Live/real-
Live/real-
time
time three-dimensional transesophageal echocardiography (A,B). The arrow pointstotothe
three-dimensional transesophageal echocardiography (A,B). The arrow points thecatheter
catheter
deployment device passing through MVR and bypassing the TH in MPR mode in A and in full
deployment device passing through MVR and bypassing the TH in MPR mode in A and in full
volume mode in B Abbreviations as in previous Figures.
volume mode in B Abbreviations as in previous Figures.
J. Clin. Med.
J. Clin. 2022,11,
2022,
Med. 11,7084
x FOR PEER REVIEW 9 of 16 10 of 16
(A)
(B)
(C)
Figure 5. Cont.
J. Clin. Med. 2022, 11, 7084 11 of 16
J. Clin. Med. 2022, 11, x FOR PEER REVIEW 10 of 16
(D)
Figure
Figure5.5.(A–D),
(A–D),Video S2. S2.
Video 58-year-old female
58-year-old with severe
female mitral valve
with severe mitralstenosis followingfollowing
valve stenosis mitral mitral
annuloplasty ring implantation 4 years previously (Case 8). Pre-procedure. Two-dimensional
annuloplasty ring
transesophageal implantation 4(A).
echocardiography years previously
Shows a large TH(Case 8). Pre-procedure.
(arrow) attached to the Two-dimensional
LA body wall trans-
esophageal
adjacent to AOechocardiography
in A. Spontaneous(A). Shows
contrast a large
echoes TH (arrow)
suggestive of a attached
low flow to theare
state LAalso
body wall adjacent
noted
adjacent
to AO intoA.the TH. Live/real-time
Spontaneous three-dimensional
contrast echoes suggestive transesophageal
of a low flowechocardiography (B). adjacent
state are also noted The to the
large TH attached to the
TH. Live/real-time LA body viewed in
three-dimensional different cuttingechocardiography
transesophageal planes is demonstrated(B). in
TheB together
large TH attached
with spontaneous contrast echoes. Areas of echolucencies noted within the thrombus are consistent
to the LA body viewed in different cutting planes is demonstrated in B together with spontaneous
with thrombus lysis. During Procedure. Live/real-time three-dimensional transesophageal echocar-
contrast echoes.
diography (C, VideoAreas of arrow
S2). The echolucencies
in C pointsnoted
to thewithin
catheterthe thrombusdevice
deployment are consistent with thrombus
passing through
lysis.
the ringDuring
(R) andProcedure.
avoiding theLive/real-time
thrombus in fullthree-dimensional
volume mode (Video transesophageal echocardiography
S2). Post-procedure. Two-di- (C,
mensional
Video S2).transesophageal
The arrow in echocardiography (D). Demonstrates
C points to the catheter deployment the device
new prosthesis
passing in the fully
through the ring (R)
open position in D. Abbreviations as in previous Figures.
and avoiding the thrombus in full volume mode (Video S2). Post-procedure. Two-dimensional
transesophageal
Table echocardiography (D). Demonstrates the new prosthesis in the fully open position
1. Patient Characteristics.
in D. Abbreviations as in previous Figures.
Transcatheter
Pre procedure Surgical
Case #. Age/Sex In all patients,
MVR/Date/Other systematic
Associated and meticulous cropping of 3D datasets was used to com-
Comorbidities
MVR/Date/Other Interventions
prehensively evaluate as much of the LA and LAA as possible to exclude any additional
Interventions
thrombus
Boston Lotus, 27 or anyCKD,
other structural
DM, abnormality
HTN, PAD, CAD, which
Tissue MVR could poseMR,
for severe a hazard
TVA forduring the
Case 1. 74/F transcatheter procedure. chronic
Determination of the size of the prosthetic
mm/1/6/2016 AF severe TR/2011MV to be implanted
and other parameters such as left ventricular outflow tract size were determined using
Boston Lotus, 27 ESRD, chronic hepatitis B with Tissue MVR for severe MR, 31
Case 2. 56/F echocardiography and computed tomography scans as described previously [10].
mm/1/11/2016 acute exacerbation, CAD, HTN mm/2003
Edwards SAPIEN, 26 Pulmonary hypertension, Tissue MVR for severe MR, TVA for
Case 3. 55/M
mm/3/14/2016 chronic AF severe TR/09/20/2010
Edwards SAPIEN XT, 29
Tissue MVR for severe MR, tissue
Case 4. 67/M mm and redo AVR for CAD, chronic AF
AVR for severe AR/2009
severe AS/11/14/2016
Cardiogenic shock, ESRD, HTN, Tissue MVR for severe MR, 31
Edwards SAPIEN XT, 29
Case 2. 58/F CAD, chronic hepatitis B with mm/2003, transcatheter MVR for se-
mm/9/21/2018
acute exacerbation vere MS/1/11/2016
Edwards SAPIEN XT, 29 Tissue MVR for severe
Case 5. 61/M HBV carrier, chronic AF, CAD
mm/11/4/2018 MR/11/13/2009
Edwards SAPIEN, 26 COPD, antithrombin III defi- Tissue MVR for severe MR, TVA for
Case 6. 64/F
mm/4/29/2020 ciency, obstructive sleep apnea moderate TR/11/04/1998
J. Clin. Med. 2022, 11, 7084 12 of 16
Mild MR,
Case 2. moderate TR,
Stenosis/19 1.09 LAA + LA body 2.0 1.2 0.8 2.68 1.86 0.82 Yes 0.07 0.53 3.7
1/11/2016 normal LV/RV
function
Mild MR,
moderate TR,
Case 10. Stenosis/13 mild AR, mild
0.72 LAA + LA body 10.5 3.9 6.6 17.74 6.12 11.6 Yes 0.37 2.33 26
5/10/2021 PR, normal
LV/RV function
Table 2. Cont.
Largest Thrombus Area by 2D Echo Largest Thrombus Area by 3D Echo Thrombus
Severe MVR Stenosis/MPG (mmHg) Thrombus Location Largest Echolucency Largest Echolucency
Case #. Date of or Severe MVR Regurgitation
MVA by 3D Echo
by 2D Echo and 3D Planimetry(cm2 ) Planimetry (cm2 ) Mobility by 2D
in Thrombus in Thrombus Thrombus Volume Associated
MV in V by 2D Echo Planimetry (cm2 ) Echo
Echo and 3D
by 2D Echo (cm2 ) by 3D Echo (cm2 ) by 3D Echo (mL) Findings
Total LAA LA Body Total LAA LA BODY Echo
2D echo = Two-dimensional transesophageal echocardiography, 3D echo = Three-dimensional transesophageal echocardiography, AR = Aortic regurgitation, AS = Aortic stenosis,
LA = Left atrium body, LAA = Left atrial appendage, LV = Left ventricle, MPG = Mean pressure gradient, MR = Mitral regurgitation, MVA = Mitral valve orifice area, MV in
V = Transcatheter mitral valve in bioprosthetic mitral valve procedure, MVA = Prosthetic mitral valve area, MVR = Mitral valve replacement, PR = Pulmonary regurgitation, RV = Right
ventricle, TR = Tricuspid regurgitation. Largest thrombus area by 2D echo and 3D echo and largest echolucency in thrombus by 2D echo and 3D echo are in cm2 . * MR vena contracta
area by 3D planimetry in cases 11 and 12 was 0.44 cm2 and 1.25 cm2 , respectively.
J. Clin. Med. 2022, 11, 7084 14 of 16
4. Discussion
To the best of our knowledge, this is the first report describing a group of patients
in whom transcatheter prosthetic MV implantation utilizing the transapical method was
accomplished for a severely degenerated MV prosthesis or severe native MV stenosis
status post a surgically inserted mitral annuloplasty ring with co-existing thrombus in the
LAA and/or LA body. In a prior publication from our group, comparing surgical versus
transcatheter MV in prosthetic MV patients, two patients with thrombus in the LA were
listed in a table, but there was no further mention and no other details were provided in
the published manuscript [11]. Since fluoroscopy does not visualize intracardiac thrombi,
use of both 2D and 3DTEE was essential in finding the location and other attributes of
the thrombi such as their size and extent in our patients and guiding the transcatheter
procedure such that there was no contact with the thrombus at any time. Although in all
our patients, the procedure could be successfully performed avoiding any disruption of
the thrombus, it may be difficult to avoid it if the thrombus involved the prosthetic valve
or was very close to it or was closely related to other anatomic landmarks normally used
during the procedure such as the left upper pulmonary vein. However, in all our patients,
the thrombus did not involve any of these sites by both 2D and 3DTEE further ensuring
a successful outcome without any complications. More recently, transseptal rather than
the apical approach has been used for transcatheter MV implantation but we do not know
whether this procedure can be safely used in patients with thrombus in LAA/LA body.
3DTEE provided incremental value over 2DTEE in more comprehensively assessing
both the LAA and LA body for the presence and exact sites of location of thrombus, its
J. Clin. Med. 2022, 11, 7084 15 of 16
size, shape and mobility characteristics as well as thrombus volume which is a superior
parameter of size than thrombus area measured by planimetry [9,14,15]. These findings
helped the operator in carefully guiding the guide wire and the prosthesis deployment
system as they traversed through the degenerated bioprosthetic MV/native stenotic MV
and annuloplasty ring into the left atrium bypassing the thrombus. In all our patients,
3DTEE, unlike 2DTEE, also facilitated en face view of the degenerated bioprosthetic MV
leaflets which permitted accurate measurement of the orifice area by planimetry [16].
In addition, color Doppler en face views of vena contracta of the mitral regurgitant jet
facilitated measurement of vena contracta areas permitting more accurate assessment
of regurgitation severity [17]. 3DTEE also provided increased confidence level during
deployment of the MV prosthesis. Another additive value of 3DTEE was the ability to
ensure the absence of any residual valvular or paraprosthetic MR following the procedure
with a greater degree of certainty than using 2DTEE alone since the prosthesis could be
viewed in multiple projections.
5. Conclusions
Our series of 12 patients shows the feasibility of successfully performing transcatheter
bioprosthetic MV in surgically implanted degenerated MV prostheses or severe native MV
stenosis following a surgically implanted mitral annuloplasty ring in patients with throm-
bus present in the LAA and/or LA body. All of these patients had a high or prohibitive
risk for repeat operation and all absolutely refused redo surgery. Utilization of both 2D
and 3DTEE especially 3DTEE was essential in avoiding contact with the thrombus and
preventing any embolic complications in these exceptional cases. Our number of cases is
small, and a much larger study is needed to assess the safety and efficacy of this procedure
in such patients.
Supplementary Materials: The following supporting information can be downloaded at: https:
//www.mdpi.com/article/10.3390/jcm11237084/s1, Video S1: Shows both fixed (left arrow) and
mobile (right arrow) components of the thrombus in left atrium. Video S2: Shows catheter deployment
device passing through the mitral annuloplasty ring and avoiding the thrombus in the left atrium.
Author Contributions: Conceptualization, M.-C.H., W.-H.Y., Y.-T.L., T.-P.T., J.W. and Y.-T.L., method-
ology, M.-C.H., W.-H.Y., Y.-T.L., T.-P.T. and J.W., formal analysis, M.-C.H., Z.M.E., N.C.N., A.D., S.D.
and B.M., writing—original draft preparation, N.C.N., A.D., S.D. and Z.M.E., writing—review and
editing, M.-C.H. and N.C.N. Supervision, M.-C.H. and N.C.N. All authors have read and agreed to
the published version of the manuscript.
Funding: This research received no external funding.
Institutional Review Board Statement: The study was conducted in accordance with the Declaration
of Helsinki, and approved by the Institutional Review Board of Cheng Hsin General Hospital, Taipei,
Taiwan (CHGH-IRB No. (523) 104-59-3, 10 June 2021) and The University of Alabama at Birmingham,
Birmingham, AL, USA (IRB-170307006, 11 February 2022).
Informed Consent Statement: Informed consent was obtained from all subjects involved in the study.
Data Availability Statement: All patient data kept confidentially with Cheng Hsin General Hospital,
Taipei, Taiwan.
Conflicts of Interest: All authors declare no conflict of interest.
References
1. Dvir, D.; Bourguignon, T.; Otto, C.M.; Hahn, R.T.; Rosenhek, R.; Webb, J.G.; Treede, H.; Sarano, M.E.; Feldman, T.;
Wijeysundera, H.; et al. Standardized definition of structural valve degeneration for surgical and transcatheter bioprosthetic
aortic valves. Circulation 2018, 137, 388–399. [CrossRef] [PubMed]
2. Friedrich, I.; Simm, A.; Kötting, J.; Thölen, F.; Fischer, B.; Silber, R.-E. Cardiac surgery in the elderly patient. Dtsch Arztebl Int.
2009, 106, 416–422. [CrossRef] [PubMed]
J. Clin. Med. 2022, 11, 7084 16 of 16
3. Urena, M.; Himbert, D.; Brochet, E.; Carrasco, J.L.; Iung, B.; Nataf, P.; Vahanian, A. Transseptal transcatheter mitral valve
replacement using balloon-expandable transcatheter heart valves. J. Am. Coll. Cardiol. Interv. 2017, 10, 1905–1919. [CrossRef]
[PubMed]
4. Sondergaard, L.; Brooks, M.; Ihlemann, N.; Jonsson, A.; Holme, S.; Tang, M.; Terp, K.; Quadri, A. Transcatheter mitral valve
implantation via transapical approach: An early experience. Eur. J. Cardiothorac. Surg. 2015, 48, 873–877, discussion 877–878.
[CrossRef] [PubMed]
5. Vohra, H.A.; Whistance, R.N.; Roubelakis, A.; Burton, A.; Barlow, C.W.; Tsang, G.M.; Livesey, S.A.; Ohri, S.K. Outcome after
redo-mitral valve replacement in adult patients: A 10-year single-centre experience. Interact. Cardiovasc. Thorac. Surg. 2012, 14,
575–579. [CrossRef] [PubMed]
6. Gallo, M.; Dvir, D.; Demertzis, S.; Pedrazzini, G.; Berdajs, D.; Ferrari, E. Transcatheter valve-in-valve implantation for degenerated
bioprosthetic aortic and mitral valves. Expert Rev. Med. Devices 2016, 13, 749–758. [CrossRef] [PubMed]
7. Otto, C.M.; Nishimura, R.A.; Bonow, R.O.; Carabello, B.A.; Erwin, J.P.; Gentile, F.; Jneid, H.; Krieger, E.V.; Mack, M.; McLeod, C.;
et al. 2020 ACC/AHA guideline for the management of patients with valvular heart disease: Executive summary: A report of the
American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation 2021,
143, e35–e71. [CrossRef] [PubMed]
8. Sinha, A.; Nanda, N.C.; Khanna, D.; Dod, H.S.; Vengala, S.; Mehmood, F.; Agrawal, G.; Upendram, S. Morphological assessment
of left ventricular thrombus by live three-dimensional transthoracic echocardiography. Echocardiography 2004, 21, 649–655.
[CrossRef] [PubMed]
9. Thind, M.; Ahmed, M.I.; Gök, G.; Joson, M.; Elsayed, M.; Tuck, B.C.; Townsley, M.M.; Klas, B.; McGiffin, D.C.; Nanda, N.C.
Incremental value of three-dimensional transesophageal echocardiography over the two-dimensional technique in the assessment
of a thrombus in transit through a patent foramen ovale. Echocardiography 2015, 32, 848–854. [CrossRef] [PubMed]
10. Murphy, D.J.; Ge, Y.; Don, C.W.; Keraliya, A.; Aghayev, A.; Morgan, R.; Galper, B.; Bhatt, D.L.; Kaneko, T.; Di Carli, M.; et al. Use
of cardiac computerized tomography to predict neo-left ventricular outflow tract obstruction before transcatheter mitral valve
replacement. J. Am. Heart Assoc. 2017, 6, e007353. [CrossRef] [PubMed]
11. Hsiung, M.-C.; Yin, W.-H.; Lee, Y.-T.; Tsao, T.-P.; Lee, K.-C.; Huang, K.-C.; Chen, P.-E.; Chiang, W.-H.; Tung, T.-H.; Wei, J. Effects of
transapical transcatheter mitral valve implantation. Front. Cardiovasc. Med. 2021, 8, 633369. [CrossRef] [PubMed]
12. Kapadia, S.R.; Makkar, R.; Leon, M.; Abdel-Wahab, M.; Waggoner, T.; Massberg, S.; Rottbauer, W.; Horr, S.; Sondergaard, L.;
Karha, J.; et al. Cerebral embolic protection during transcatheter aortic valve replacement. N. Engl. J. Med. 2022, 387, 1253–1263.
[CrossRef] [PubMed]
13. Shivaraju, A.; Michel, J.; Frangieh, A.H.; Ott, I.; Thilo, C.; Schunkert, H.; Kastrati, A.; Leon, M.B.; Dvir, D.; Kodali, S.; et al.
Transcatheter aortic and mitral valve-in-valve implantation using the Edwards Sapien 3 heart valve. J. Am. Heart Assoc. 2018,
7, e007767. [CrossRef] [PubMed]
14. Nanda, N.C.; Rahman, S.M.A.-E.; Khatri, G.; Agrawal, G.; El-Sayed, A.A.; Hassanian, H.A.S.; Kamran, M.; Kirklin, J.;
McGIFFIN, D.C.; Holman, W.L.; et al. Incremental value of three-dimensional echocardiography over transesophageal multiplane
two-dimensional echocardiography in qualitative and quantitative assessment of cardiac masses and defects. Echocardiography
1995, 12, 619–628. [CrossRef]
15. Anwar, A.M.; Nosir, Y.F.M.; Ajam, A.; Chamsi-Pasha, H. Central role of real-time three-dimensional echocardiography in the
assessment of intracardiac thrombi. Int. J. Cardiovasc. Imaging 2010, 26, 519–526. [CrossRef] [PubMed]
16. Faza, N.N.; Little, S.H. Role of 3-dimensional transesophageal echocardiography in guiding transcatheter mitral valve replacement.
Echocardiography 2020, 37, 945–953. [CrossRef] [PubMed]
17. Zeng, X.; Levine, R.A.; Hua, L.; Morris, E.L.; Kang, Y.; Flaherty, M.; Morgan, N.V.; Hung, J. Diagnostic value of vena contracta
area in the quantification of mitral regurgitation severity by color Doppler 3D echocardiography. Circ. Cardiovasc. Imaging 2011, 4,
506–513. [CrossRef] [PubMed]