ECG ENGINEERING CONSULTANTS GROUP TABLE OF CONTENTS
KSA 000010 - 2970 1
CONTENTS
VOLUME I
(Not Included)
VOLUME II
DIVISION 0: INFORMATION
VOLUME III
TECHNICAL SPECIFICATIONS – PART A
Divisions 03 Concrete
Divisions 04 Masonry
Divisions 05 Metals
Divisions 09 Finishes
Division 10 Specialties
Division 22 Plumbing
Division 26 Electrical
Division 31 Earthwork
Division 33 Utilities
X
REV. DATE PREPARED REVIEWED APPROVED PAGES REMARKS x
NO. BY BY BY X
SPECIFICATION REV.
ECG ENGINEERING CONSULTANTS GROUP METHOD OF MEASUREMENT
KSA 012700 - 2970 1
METHOD OF MEASUREMENT
1. These notes are intended as a guide only to the method adopted in the preparation of
the Bill of Quantities and the measurement of the Works. Contractors must note that
rates for items must include furnishing and everything necessary for the proper
execution, erection, completion and maintenance of each item and that all auxiliary
work is included unless specifically otherwise stated, measured or excluded in writing by
the Engineer.
3. Rates must include work at all levels, furnishing, transportation and installation,
materials and goods, scaffolding and testing where applicable. Each item includes also,
unless otherwise specifically stated, all labor in making, materials, goods and all costs in
connection therewith (e.g. conveyance, delivery, unloading, storing, unpacking,
returning packing, handling, hoisting, lowering and the like), fitting, setting and fixing
materials and goods in position, all square raking and curved cutting, waste of and laps
in materials, use of plant, temporary works, patterns, models, templates, samples and
establishment and overhead charges and profit.
4. Quantities are billed to the nearest whole unit. Fractions of a unit less than half are
disregarded and all other fractions are regarded as whole units.
7. Attention is also directed to the Specifications and Drawings, which contain further
notes on all work, required and which are deemed to be included in rates quoted in
attached Bills of Quantities.
9. Rates include cost of removal of rubbish and debris from the site.
10. Full payment for any equipment shall not be made until the equipment has successfully
passed acceptance testing. After installation, but prior to successful testing, each
equipment shall be paid for at 80 percent of the unit price stated in the BOQ.
The Engineer shall withhold full payment on any equipment deemed unsatisfactory due
to any defect until such defect has been corrected in accordance with the intent of
Contract Documents.
If within the Defects Liability Period, any equipment, although originally accepted, is
actually not acceptable due to subsequent defect, the Contractor shall repair or replace
the defected equipment at his sole expense, and the Defect Liability Period with respect
Rates for all equipment include for testing at manufacturer's premises and for all spare
parts needed during the Defects Liability Period.
11. Rates for all equipment include testing at manufacturer’s premises and all spare parts
needed during the Defects Liability Period.
12. Rates shall represent full compensation for all plant, materials, transport, labor,
equipment, temporary works, establishment, overhead, profit, and tax charges required
to complete the work described in this sub-section of the specification and/or on the
drawings.
13. Rates shall include all facilities and equipment for testing and inspection by the
Employer's representatives, including transportation.
14 Rates for all equipment including locally testing at manufacturer’s premises and for all
spare parts needed during the Defects Liability Period.
15 Any item that is required for a specific task and does not have a special corresponding
item in the BOQ is considered included in the price of this task.
16 Rates shall include wiring to and from equipment, cables, cable trays, conduits, panels
and all accessories.
CONCRETE
Plain Concrete
MASONRY
Measurements shall be for net areas; areas less than 0.25 sq.m will not be
deducted.
METALS
m Access cover:
Sundries
Steel Lintels
Payment for loose steel lintels is included in unit price of concrete
masonry. No separate measurement is made.
055213 Pipe and Tube Railings
OPENINGS
No. Classified according to type, finish, and size, as per Drawings & Door
Schedules.
No. Classified according to type, size, finish, frame type, as per Drawings & Door
Schedules.
No. Classified according to material, finish, type, size, operation, and fire rating
period as per Drawings & Door Schedules.
No. Classified according to type, finish and size as per Drawings & windows
Schedules.
No. Classified according to hardware set as per Door hardware set Schedule.
088300 Mirrors
FINISHES
093000 Tiling
Ceramic Skirting
Terrazzo base
099100 Painting
SPECIALTIES
FIRE SUPPRESSION
Control Panels
Horn/Strobe Units
Alarm Bells
Strobe lights
Abort switches
Discharge Nozzles
Warning signs
Piping Network
Classified by size.
PLUMBING
Piping
Valves
This method is applicable for all types of valves, unless otherwise indicated
Supply of pump sets complete with electric control panels, all accessories,
strainers, pressure switches, fittings, fasteners, supports, bracing, gaskets,
and bolts.
All necessary wiring, power cables, vibration isolators prefabricated
bedplates, connecting flanges complete with tapping, motors, casings,
impellers, couplings, bearings and seals, casing, air release valves,
pressure regulators, pressure gauges, pressure switches, glands, starters,
control and remote devices, control cables, control valves.
Seals, bearings, delivery, bends, guide rails, float switches, lifting chains
with identification tags.
All special pieces for installation and operation.
232113 HVAC
To
238400 General
Contractors must note that rates of items include everything necessary for
the proper supply, installation, execution, completion, start-up and
maintenance of each item that all auxiliary work is included unless specifically
otherwise stated, measured or excluded in writing by the Engineer.
Rates shall be fully inclusive of all that is necessary to fulfill the liability and
obligations and shall include:
Package roof top unit , split unit , fans or the like are classified according to
type.
Outlets Fittings
262413 Switchboards
263533 Power Factor Correction Capacitors
No. Classified according to type, voltage, form of separation and ratings.
263213 Generators
- Supply, installation, testing and commissioning of the unit with control panel,
fuel system, battery set, battery charger, Sound Attenuation and fuel tanks.
- Provision of connections between fuel storage tank and daily tank and
solenoid valve required, cooling, set of pumps, exhaust system, lubrication
system, grounding tapes, noise suppressors silencer, vibration suppressors,
ventilation works, concrete base and louvers.
- Transportation to the project
- Spare Parts as indicated in the specifications.
- All associated civil work relevant to fixation and installation.
- Detailing, fabrication, delivery, assembly, installation of all accessories.
- Testing before shipping in the factory on load bank and on testing on site
after installation on the actual loads of the complete system, spare parts,
catalogues and manuals.
- And all necessary accessories to complete the work according to the
No. Initiating Devices (Intelligent addressable multi detector, Manual Station, etc)
EARTHWORK
Excavation m3
Backfilling m3
UTILITIES
Pipes
331000 Unplasticized PVC Pipes (Upvc), High Density Polyethylene (HDPE), Ductile
Iron Pipes and Fittings, (DI) Ductile iron pipe and fittings
&
333000 Extra Strength Vitrified Clay (ESVC),
&
334000 Unplasticized PVC Pipes (Upvc), Reinforced Concrete Pipes (RC)
333000
& Chambers
334000 Wastewater and Storm Drainage Structures
No. Manholes
No. Classified according to type, width, length and depth from ground level to
bottom elevation of the chamber.
No. Classified according to type, width, length and depth from ground level to
bottom elevation of the chamber.
No. Classified according to type, diameters, and depth from ground level to bottom
elevation of the main pipe invert level.
No. Classified according to type, diameters, and depth from ground level to
bottom elevation of the main pipe invert level.
No. Classified according to type, diameters, and depth from ground level to
bottom elevation of the main pipe invert level.
Service Connection
No. Cranes
Are classsified according to lifting capacity. Rates shall include supply and
installation of all necessary girders, traveling rails and beams, wheels, and
carriage limit switches, control panel of control devices safety devices,
cables, festoon, steel fabrication fasteners, crane trolley, chains and all
accessories required for proper operation testing and putting into services.
SPECIFICATION REV.
ECG ENGINEERING CONSULTANTS GROUP
BILL OF QUANTITIES
KSA 012750 – 2970 1
SPECIFICATION REV.
ECG ENGINEERING CONSULTANTS GROUP LIST OF MANUFACTURES
KSA 012950 - 2970 1
1. Contractor should abide by the manufacturers listed below OR equal approved by the
Engineer, comply with the Project Specifications, obtain accredited Test Reports
along with approved record of similar successful interventions in projects.
a. A letter from the Mother Company listed in the LOM certifying that the
submitted product is manufactured in that factory in such location under the
Company quality control protocol and supervision, and stating that the factory
is one of the Company’s accredited factories.
b. In case of any deviation from Specifications and specified performance
requirements, Engineer has the right to request further testing in an approved
independent laboratory accepted by the Engineer on Contractor's Expense to
demonstrate compliance of the product with the Project specifications.
List of Manufacturers
Riyadh Sedra 2 (Prj. 2970) Section 012950
Page 1 of 6
SECTION PRODUCT MANUFACTURER
No.
Henkel
071616 Crystalline Waterproofing Velosite
Xypex
Vandex
BASF
075216 Styrene-Butadiene-Styrene (SBS) Modified Bitumat
Bituminous Membrane Awazel
Henkel
075123 & Atactic- Polypropylene (APP) Modified Dermabit
075216 Bituminous Membrane Roofing Awazel
Bitumat
078413 Penetrating fire stop Tremco
Hilti
Flame guard
Passive
079200 Joint Sealants Sika
Henkel
Fosroc
081113 Steel Doors And Frames Al Kuhaimi
Al-Muhaidib
Metalco
Al Moosa
Al Manashy
Wood Master
083323 Overhead Coiling Doors Hormann
Novoferm
Ascot
Braselmann
085113 & Aluminum Windows Heuck
089000 & Louvers Al Wakeel
Reynaers
Shucco
Alumil
087100 Door Hardware Cisa
Tesa
Dorma
JNF
Amig
093000 Tiling Saudi Ceramic
Al Fanar
Al Khazaf Al Saudi
RAK
096600 Precast Terrazzo ARTIC
SACEP
096723 Resinous Flooring BASF
Sika
Fosroc
099100 Painting Jotun
Al Jazira
Sigma
Sherwin- Williams
internatinal
102800 Toilet and path accessories Aquis Sanitär AG
List of Manufacturers
Riyadh Sedra 2 (Prj. 2970) Section 012950
Page 2 of 6
SECTION PRODUCT MANUFACTURER
No.
BOBRICK
104416 Fire Extinguishers Naffco
Bristol
Sffeco
212200 Novec system ; Cylinders, Nozzles, Fike
Manifolds, Hoses, Actuators Kidde
Ansul
Detectors, Control Panels, Alarm Simplex grinnell
Devices, Manual Release Devices. System Sensor
Siemens
Notifire
Fenwal
Potter
Tyco
220523 General-Duty Valves Milwaukee Valve Company
for Plumbing Piping NIBCO INC.
Crane Co.; Crane Valve Group; Crane
Valves.
Hattersley Newman
Kitz Corporation
Tecofi
221116 Domestic Water Piping Pont-a-Mousson
“Ductile iron pipes” Mcwane
Ductile Iron
Amrican Cast Iron
SADIP
221123 Domestic-Water Packaged Pumps Aurora Pump.
KSB
Wilo
Peerless
Grundfos
Armstrong
221319 Sanitary Waste Piping Specialties Zurn
Wavin
Geberit
Sadip
MMP
Watts Drainage Products Inc.
Josam Company; Josam Div.
Saudi cast
221329 Sanitary Sewerage ABS /Sulzer
Pumps Homa
Grundfos
Flygt AB
KSB
Salmson
230700 HVAC Insulation Saudi Rockwoool
Kimmco
Arabian Fiberglass Insulation Co. Ltd.
(Afico)
Armacell
K FLEX
Adhesive Foster
Fevicol
List of Manufacturers
Riyadh Sedra 2 (Prj. 2970) Section 012950
Page 3 of 6
SECTION PRODUCT MANUFACTURER
No.
232300 Refrigerant Piping Yorkshire
Kembila
Flowflex
Crane
MKM
233113 Metal Ducts Safid
Arabian thermal air industries
Saudi duct factory
233300 Air Duct Accessories Ruskin Company.
BETEC CAD
BCI
Trox
Safid
Saudi duct factory
233423 HVAC Power Ventilators Greenheck.
Helios
TLT
Prollrichdlk
Fabresse
S&P
Woods
Casals
SODECA
Ferrari
System Air
Nicotra
Rosenberg
233713 Diffusers, Registers, And Grilles BCI.
Gulf grills
Saudi Euro register
Titus
Flowtech
237413 Package, Outdoor, Roof Top Units Carrier
Trane
York
Daikin
Petra
Zamil
238126 Split-System Air-Conditioners York
SKM
LG
Zamil
260513 Medium Voltage Electrical Power Cables Jeddah cables
Saudi cables
Riyadh cables
Bahra Cable
ALFANAR (Elecra Cables)
260519 LV electrical power Conductors and Cables Jeddah cables
Saudi cables
Riyadh cables
Bahra Cable
ALFANAR (Elecra Cables)
260526 Grounding and Bonding for electrical system Furse
Kingsmill
Wallis
Erico
260533 Raceways and Boxes for electrical systems Ega tube
(UPVC Conduits, Boxes and Wall) ALFANAR
List of Manufacturers
Riyadh Sedra 2 (Prj. 2970) Section 012950
Page 4 of 6
SECTION PRODUCT MANUFACTURER
No.
Decoduct
Clipsal
Galvanized Steel Conduits and Boxes Allied
Wheatland
Burn
Smart tube
Panasonic
ABB (Steel city (for steel box))
ABB (Thomas and Betts (for Steel Boxes))
Flexible Conduits Flexicon
Kopex
Dielectrix
260536 Cable trays Saudi Electric Industries
Decoduct
Al-Misbah Fabricators Co.
261201 Transformer ABB
Al Fanar
Saudi Transformer company (STC)
261301 Ring Main Unit Schneider Elec.
ABB
Siemens
Al Fanar
Eaton
262726 Wiring Devices ABB
Switches and Sockets Siemens
ALFANAR
(As per Architect & ID Selection) MK Electric Limited
ALF
Industrial Sockets Clipsal
Legrand
Eaton
Gewiss
Schneider
ABB
Load break switches ABB (GE)
Socomec
Schneider
ABB
Katko
Gewiss
Bticino
Eaton
262413 & Switchboard & Schneider Elec.
262416 & Panelboards & ABB
263533 & Power Factor Correction & Siemens
262419 MCC ALFANAR
Variable Speed Drive (VSD) ABB
Schneider Electric
Siemens
GE
263213 Stand by Generator Caterpillar
Cummins
MTU
FG Wilson
Mitsubishi Electric Saudi Ltd.
List of Manufacturers
Riyadh Sedra 2 (Prj. 2970) Section 012950
Page 5 of 6
SECTION PRODUCT MANUFACTURER
No.
SDMO
263600 Automatic Transfer Switches (ATS) ASCO
(Double throw technology) GE -zenith
265100 & Interior lighting & Saudi lighting
265600 Exterior Lighting Inara
(According to lighting fixture schedule and Philips
ID selection ) Schreder
283100 Fire Alarm System Edwards Systems Technology
Notifier by Honeywell
Siemens
Fire alarm Cables MESC
EL-Sewedy
ITALCOND
331000 Water Supply Networks Fusion Equipment ISCO Industries
HDPE Pipes and Fittings Arkan Development Company
Saudi Pipe System SPS
Cosmoplast HDPE
Ductile Iron Pipes and Fittings Sertopi
Saudi Arabian Ductile Iron Pipes SADIP
AMIANTIT
Saudi Pipe System SPS
Infrastructure valves VAG
Crane Co. Valves and Fittings
Kennedy Valve
Div of ITT
Viking Johnson
Bimex Somepal
Master Meter
Saudi Pipe System SPS
Mega Coupling
Saint Gobain
AVK
Sitrans Flow meters
Bristol
Pratt
Valve chambers and Covers Saint Gobain
Saudi Pipe System SPS
RVK
412215 Overhead Crane Yale
Dresser
Hadef
Kuhnezug
Stahl
List of Manufacturers
Riyadh Sedra 2 (Prj. 2970) Section 012950
Page 6 of 6