RAIN SHOWER
ROBE HOOK
TOWEL BAR
H=0.75m. ON VANITY
H=RANGES 0.787m. TO 0.85m. H=1.20m ON WALL
VARIES DEPEND ON LAVATORY TYPE
VERIFY HEIGHT ON SUPPLIER REQUIREMENT
X
SOAP HOLDER
H=0.90m. ALONG BATH TUB
H=1.40m. ALONG SHOWER
HOT COLD
D
C
FFL FFL FFL FFL FFL
ABLUSION HOSE TOILET PAPER LIQUID SOAP DISPENSER FASCIAL MIRROR, SOAP HOLDER, SHELF, LAVATORY ROBE HOOK, TOWEL HOLDER SHOWER HEAD, SHOWER MIXER
WATER CLOSET HOLDER SOAP HOLDER
FOR SERVICE/MAID ROOM ONLY
- -
GLAZED CERAMIC
PLYWOOD LIPPED DOOR
WALL TILES
WITHOUT EDGE BINDING
SHELVES
SOAP HOLDER
BACKSPLASH BACKSPLASH
MIXER TAP
BEAM
FOUNDATION
FOUNDATION
FOUNDATION
BEAM
BEAM
FIBER WATER TANK FIBER WATER TANK
FOUNDATION
CAPACITY CAPACITY
FOUNDATION
BEAM
BEAM
(REFER TO SUPPLIER) (REFER TO SUPPLIER)
BEAM
FORM SUPPLAY
FORM SUPPLAY (SEE LAYOUT)
(SEE LAYOUT)
GRID
≥ ≥
≥ ≥
=
=
=
=
≥
≥
≥
≥
FCU / AHU
FCU / AHU
FCU / AHU
FCU / AHU
FCU / AHU
FCU / AHU
FCU / AHU
FCU / AHU
FCU / AHU
FCU / AHU
FCU / AHU
FCU / AHU
FCU / AHU
FCU / AHU
Saudi Electricity Company Saudi Electricity Company
T
FCU / AHU
OUTDOOR UNIT
REF. PIPE (SUCTION LINE)
5/8 -∅ (16mm ∅)
WELDED ANGULAR
STEEL BASEFRAME
REF. PIPE (SUCTION LINE)
FINISHED FLOOR LINE
5/8 -∅ (16mm ∅)
KNOCK OUT HOLE THROUGH BACK FOR INSULATION FOR REF PIPE
W A L L
REF. PIPE POWER SUPPLY & CONTROL
WIRES, DRAIN PIPE 76mm ∅
POWER SUPPLY WIRE
2
(2-10mm + 1-6mm (G) +
INDOOR UNIT 1-3/C-2.5mm CONTROL WIRES)
P R O P E R T Y
REMOTE CONTROL PVC SLEEVE 76 mm ∅
(RECOMMENDED HEIGHT
FROM F.F LINE 1600 mm)
WIDTH = 360 mm
20mm ∅ DRAIN PIPE
TAP TO THE NEAREST
THICKNESS = 220mm DRAIN PIPE.
S E C T I O N D E T A I L - 'A'
REF. PIPES & POWER SUPPLY
WIRES FOR SPLIT A/C UNITS S E C T I O N
SCECO METER
CABLE CONNECTION
NOT TO SCALE
SPLIT UNIT INSTALLATION
NOT TO SCALE
GROUND TEE CABLE
SPLICE CABLE
TO GROUND ROD
L TO 2L
CABLE TO CABLE
GROUNDING CONNECTION
THROUGH CABLE
TO GROUND ROD
AIR TERMINAL DETAILS
75
135
DETAIL - C
SQUARE CLAMP SERVICE EQUIPMENT GROUNDING CONNECTION