LEMATANG COMPRESSOR

INSTALLATION

MOTOR DATA SHEET


~
W PT. SURYA Bl!SIHDO SAKTI
.c_ _ _ .. ,~s:.n....;

GAS COOLER & LUBE OIL COOLER (32-HAL-201AB)


Doc. No. : SGA-M-DS-32-105

CLIENT : MEDeo E&P LEMATANG

PROJECT TITLE : LEMATANG COMPRESSOR INSTALLATION

LOCATION : SINGA CPP, LEMATANG, SOUTH SUMATRA

'? r
fInr&Jy­ d ~
0 13-March-2019 ISSUE FOR COMMENT ! "-m~ ?ab rwx
REV. NO DATE DESCRIPTION PREP'D CHK'D APP'D
LEMATANG COMPRESSOR
INSTALLATION
MECHANICAL DATA SHEET
GAS COOLER (32-HAL-201A)
Doc. No. : SGA-M-DS-32-105

REVISION CONTROL SHEET

REV. NO DATE DESCRIPTION

Page 2 of 4
Rev. 0
LEMATANG COMPRESSOR
INSTALLATION
MECHANICAL DATA SHEET
GAS COOLER (32-HAL-201A)
Doc. No. : SGA-M-DS-32-105

TABLE OF CONTENTS

SECTION Page

1. Motor DataSheet (32-HAL-201AB) .................................................................................................. 4

Page 3 of 4
Rev. 0
No.: 1180
WEG Industrias S.A Date: 04-MAR-2019

DATA SHEET
Three-phase induction motor - Squirrel cage rotor
Customer : PT.Surya Besindo Sakti
Product line : Explosion Proof Motors (Exd) - Standard Efficiency - IE1

Frame : 200L
Output : 22 kW
Frequency : 50 Hz
Poles : 4
Full load speed : 1470 rpm
Slip : 2.00 %
Voltage : 400/690 V
Rated current : 41.4/24.0
A Locked rotor current : 311/180 A
Locked rotor current (Il/In) : 7.5
No-load current : 18.0/10.4
A Full load torque : 143 Nm
Locked rotor torque : 280 %
Breakdown torque : 280 %
Design : ---
Insulation class : F
Temperature rise : 80 K
Locked rotor time : 14 s (hot)
Service factor : 1.15
Duty cycle : S1
Ambient temperature : -20°C - +40°C
Altitude : 1000 m
Degree of Protection : IP55
Approximate weight : 290 kg
Moment of inertia : 0.20883 kgm²
Noise level : 64 dB(A)

D.E. N.D.E. Load Power factor Efficiency (%)


Bearings 6311 ZZ-C3 6211 ZZ-C3 100% 0.83 91.3
Regreasing interval --- --- 75% 0.78 91.3
Grease amount --- --- 50% 0.67 91.0

Notes:
.Winding RTD-PT 100 3 wires (2/phase)
.Bearing RTD-PT 100 3 wires (1/bearing)
.Vibration sensor Vibraswitch Robet shaw 366
.Insulated NDE Bearing
.Space Hater 230v-50Hz/1Ph
.Performance Type test

Efficiencies according to the indirect method of IEC 60034-2-1:2007 with stray load losses determined from
measurement.

Performed by Checked
Yusuf.S Automatic
1 2 3 4 5 6 7 8

Notes:
E

A AA AB AC AD Performed by: Yusuf.S


318 82 385 399 370
B BA BB C CA Checked: Automatic
305 85 370 133 222
D E ES F G Customer: PT.Surya Besindo Sakti
55m6 110 80 16 49
GD DA EA TS FA Explosion Proof Motors (Exd) - Standard Efficiency - IE1
10 48k6 110 80 14
F GB GF H HA HC
42.5 9 200 30 403
HD K L LC S1
474 18.5 767 880 2xM50x1,5 Three-phase induction motor 04-MAR-2019
d1 d2 Frame 200L - IP55 1180
DM20 DM20

You might also like