Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

TECHNICAL

DATA SHEET
Customer: Ref.:
Item Quantity Required flow 18 l/s Required head 15 m
Type SUBMERSIBLE ELECTRIC PUMP rate
Model E6KX60/3+MCR475-8V
separatore

Dimensions [mm]
A 1351.5 E 96
B 651.5 F Rp4
C 700 G 68.5
D 132 Ø max 144.5
separatore

OPERATING DATA- ISO 9906:2012 3B - M.E.I.≥0.40 CONSTRUCTION CHARACTERISTICS


Q [l/s] H [m] P [kW] η [%] NPSH [m] Delivery diameter Rp4 n.d.
Max. overall diameter 144.5 mm
Weight of electric pump 40.9 Kg
No. Stages 3
Motor seal Mechanical
Type of installation Vertical
separatore

OPERATING LIMITS PUMP MATERIALS ****


Pumped liquid Water Impeller Stainless steel
Max. temp. of pumped liquid (*) 30 °C Shaft bearing bush Silicon
Maximum density 1 kg/dm³ Diffuser Stainless steel
Maximum viscosity 1 mm²/s Valve casing Stainless steel
Maximum solid content 50 g/m³ Strainer Stainless steel
Max. number of starts/hr 15 Shaft Stainless steel
Minimum immersion depth 361.25 mm Coupling Stainless steel
Suction support Stainless steel
OPERATING CHARACTERISTICS Shaft sleeve Stainless steel
Service flow rate 19.5 l/s
Service head 17.6 m
Qmin Qmax 1.7 21.6 l/s
MOTOR MATERIALS
H (Q=0) Hmax (Qmin) 0 41.53 m Shaft Stainless steel
Power consumption at duty point 5.03 kW Sand guard Rubber
Pump efficiency Overall efficiency 66.76 52.18 % Upper bracket Cast iron
Max. pump efficiency (B.E.P.) 75.6 % Mechanical seal Ceramic/graphite
Sense of rotation (**) Anticlockwise Upper ball bearing Steel
Operating Stand-by Rotor Electrical steel
Number of pumps installed
1 0 Stator Electrical steel
Stator shell Stainless steel
ELECTRIC MOTOR CHARACTERISTICS Winding Copper
Nominal power 5.5 kW Lower ball bearing Steel
Rated frequency 50 Hz Lower bracket Aluminium
Rated voltage 400 V Diaphragm Rubber
Rated current 12.5 A Diaphragm cover Stainless steel
No. Poles Nominal speed 2 2805 1/min
Insulation class Protection class F IP68
n.d.
separatore

(*) Speed of the water outside the jacket of the motor v=0.08 m/s
Notes: (**) View from delivery port.
In case of VSD operation, refer to Use and Maintenance Instructions of the electric pump.
Pos. Date
OFFER No.
25/09/2023
- Copyright © 2016-2023 Caprari S.p.A. - All Rights Reserved.

Pag. 1 / 1

You might also like