Visually
No thread damage allowed 3
QCV Key should be straight no bending allowed No defect observed.
(90deg +/- 10deg) No casting defects allowed
Construction and parts There should be no physical defects and parts all
should be installed properly. All parts found as
per spec.
Resistance to hydrostatic When tested at pressure 2times higher than 2
pressure( at ambient temp) the test pressure, maintain this pressure for 10min No defect found
No leakage and defect should observe during
2 STRENGTH TEST testing of the QCV key
Resistance to hydrostatic Keep the QCV key into the hot water for 1 No sign of damage
pressure( at 60dec c temp) one hr and test after, at nominal pressure observed.
No sign of defect and damage observed
after dismantling. Ok
Pressure Drop testing AT different flow rate check the pressure drop, 1 Under the spec.
3 OPERATING TEST it should not allow more than 10% from the declared limit.
Actuating mechanism By putting the QCV key, it goes vertically (90deg 1
or +/- 10deg, no leakage allowed while inserted
the key into QCV
DATE 5/11/2023 NEXT REVIEW DATE 10/10/2023
Q.C PLAN NO- QCV-3108071000 FILE NAME Q.C PLAN
PREPARED BY DPG FILE NO 1
CKD BY Dinesh