GENERAL NOTES LEGEND & SYMBOLS

1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE PROVISION OF THE SEWER, WASTE & VENT SYSTEM
PHILIPPINE PLUMBING CODE THE NATIONAL BUILDING CODE & THE RULES & REGULATIONS OF THE CITY
OR MUNICIPALITY WHERE THE PROJECT WILL BE BUILT
SP SEWER PIPE
2. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND SPECIFICATION. THE ENGINEER SHALL BE VENT VENT LINE
NOTIFIED IMMEDIATELY OF ANY DISCREPANCY FOUND THEREIN.
WP KITCHEN WASTER LINE
3. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS. ANY RELOCATIONS REQUIRED FOR PROPER SS/VS SOIL/ VENT/ OUTLET SOCKET
EXECUTION OF OTHER TRADE SHALL BE WITH PRIOR APPROVAL OF THE ARCHITECT OR ENGINEER. /WS WASTE STACK
VSTW VENT STACK THRU WALL
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION, DEPTH AND
INVERT ELEVATION OF ALL EXISTING PIPES AND STRUCTURE AS VERIFIED BY THE CONTRACTOR. FCO FLOOR CLEANOUT PST-2

5. REFER TO ARCHITECTURAL PLANS FOR AREA DRAIN, CATCH BASIN, FLOOR DRAINS AND CLEAN CCO CEILING CLEANOUT
OUT LOCATION. GCO GROUND CEILING CLEANOUT

ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 2% UNLESS OTHERWISE SPECIFIED. FD FLOOR DRAIN
6.
GT GREASE TARP
PLAN
7. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S
GT GREASE TARP
INSTRUCTIONS.

8. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE, COORDINATE THE WORKS WITH THE LINE DRAINAGE SYSTEM
SERVICE CONNECTING POINT UNLESS OTHERWISE SPECIFIED.

9. ALL PIPE SIZES AND DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE SPECIFIED. DP DRAIN PIPE

10. ALL HANGERS SHALL NOT BE ANCHORED AT PURLINS, UNLESS OTHERWISE APPROVED BY THE STRUCTURAL AWP AIRCON WASTE PIPE
ENGINEER. AD AREA DRAIN
11. GROUND FLOOR RETAINING WALL TO BE PROVIDED WITH DRAINAGE SYSTEM (DRAINAGE AGGREGATE, PD PARKING DRAIN
GEOTEXTILE SLEEVE, AND PERFORATED PIPE OR EQUIVALENT) TO BE ROUTED SIDES. TOP COVER
FD FLOOR DRAIN SOCKET
OUTLET SOCKET INLET SOCKET
DD DECK DRAIN

MATERIAL SPECIFICATIONS GD GARDEN DRAIN


TDG TRENCH DRAIN & GRATING
WATER LINES RISER, DOWNFEED, MAIN DISTRIBUTION AND TAPPING WATER LINES SHALL BE
uPVC PNS 65 "NELTEX" BRAND OR APPROVED EQUAL. WATER DISTRIBUTION SYSTEM
SEWER PIPES SHALL BE POLYVINYL CHLORIDE (PVC) PIPE, SERIES 600, "NELTEX" BRAND OR APPROVED
EQUAL. CWL COLD WATER LINE
GV GATE VALVE FILTRATION CHAMBER
WASTE PIPES SHALL BE POLYVINYL CHLORIDE (PVC) PIPE, SERIES 600, "NELTEX" BRAND OR APPROVED (FILLED W/ WATER)
EQUAL. CV CHECK VALVE PST-2
YS Y STRAINER
ACU/AHU/FCU WASTE SHALL BE POLYVINYL CHLORIDE (PVC) PIPES, SERIES 600, "NELTEX" BRAND OR APPROVED FC FLEXIBLE CONNECTION
PIPE EQUAL AD SHALL BE PROVIDED WITH" THICK
1 CLOSE CELL ELASTOMETRIC THERMAL HB HOSE BIBB
INSULATION "AEROFLEX" BRAND OR APPROVED EQUAL AND INSTALLED AS PER MANUFACTURER'S
M
WM WATER METER
RECOMMENDATION. SECTION
UNION PATENTE
VENT PIPES SHALL BE POLYVINYL CHLORIDE (PVC) PIPES, SERIES 600, "NELTEX" BRAND OR APPROVED FV FLOAT VALVE
EQUAL.

DOWNSPOUTS SHALL BE POLYVINYL CHLORIDE (PVC) PIPES, SERIES 600, "NELTEX" BRAND OR APPROVED
EQUAL. PLUMBING FIXTURES
STORM DRAINAGE LINES FOR INSIDE BUILDING, SHALL BE POLYVINYL CHLORIDE (PVC) PIPES, SERIES 600, "NELTEX" LAV LAVATORY
BRAND OR APPROVED EQUAL AND REINFORCED CONCRETE DRAIN PIPE FOR OUTSIDE BUILDING.

WC WATER CLOSET
UNDERDRAINS/ SHALL BE POLYVINYL CHLORIDE (PVC) PIPES, SERIES 600, "NELTEX" BRAND OR APPROVED
PERIMETER DRAIN EQUAL.
UR URINAL
PIPES
GATE VALVES 50MMØ AND SMALLER, RISING STEM, ALL BRONZE, FEMALE THREADED, MINIMUM OF 125 PSIG
WORKING PRESSURE, SIMILAR TO "BERMAD" BRAND OR APPROVED EQUAL. 65MMØ AND LARGER, KS KITCHEN SINK
SHALL BE RISING OUTSIDE SCREW AND YOKE (OS & Y) FLANGED CONNECTION AND SHAL BE TOP COVER
IRON BODY, SIMILAR TO "BERMAD" BRAND OR APPROVED EQUAL.
WM WASHING MACHINE
SPOT DETAIL
S SLOPE

1
P-1 SCALE NTS
ALL RIGHTS RESERVED. PRINTED IN PASIG CITY, PHILS. BY RA
545(LAW GOVERNING THE PRACTICE OF ARCHITECTURE, JUNE 17,1950)
& PD49(PRO-TECTION OF INTELLECTUAL PROPERTY NOV.14,1972).
THIS PLAN OR DRAWING IS THE PROPERTY OF RAEMULAN LANDS INC.
(RLI), WHETHER THE WORK FOR WHICH THEY ARE MADE ARE
EXECU-TED OR NOT, AND NO PART OF THIS PLAN MAY BE USED OR
REPRODUCED IN ANY FORM OR BY ANY MEANS-GRAPHIC, ELECTRONIC
OR MECHANI-CAL, INCLUDING PHOTOCOPYING OR INFORMATION
STORAGE AND RETRIEVAL SYSTEMS WITHOUT THE WRITTEN
PERMISSION OF RLI.

OWNER/DEVELOPER: CONSULTANT: PROJECT NAME: SHEET CONTENTS: REVISION: DRAWING STAGE: SHEET NO.:

AS SHOWN NO. DESCRIPTION DATE


- ENGINEERING MANAGEMENT GROUP

RAEMULAN LAND INCORPORATED REG NO.:


-
-
FOR CONSTRUCTION SE1.00
PALIPARAN, DASMARIÑAS, CAVITE ISSUED BY: DATE: 2023-12-12
PTR NO.: TIN:
PLACE ISSUED: DATE: LOCATION: BLOCK NO: LOT NO: PAGE:
CONTROL NO.: GEN-PT-009-2311-TH44 & DU45 Sanitary FILE NAME: C:\Users\mralinas\Desktop\PROJECT TASK\GEN-PT-009-2311-TH44 & DU45 New Foundation Details\CADD - 12/12/2023 3:05 PM - Mark David R. Alinas