Technical Guidelines 2024

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 51

Technical

Guidelines

As of: 01.01.2024

1
Technical Guidelines

Contents
→ The items that have been marked contain new changes.

Page Page Page

1. Preliminary remarks 4 Fire extinguishers 18 and the heights of stand interiors 29


1.1 House Rules 5 Fire alarm system 18 4.9.3 Live loads/design loads 29
1.2 Opening hours 6 Acoustic/visual alarm 18 4.9.4 Escape routes / stairways 30
1.2.1 Set-up and dismantling periods 6 Smoke removal 19 4.9.5 Building materials 30
1.2.2 Opening hours during trade Sprinkler systems 19 4.9.6 Top floors 30
fairs/exhibitions 6 4.4.1.1 Construction and decorative 4.10 Misuse / Violation and liability 31
materials 19
2. Traffic on the exhibition grounds, → 4.4.1.2 Exhibiting motor vehicles 5. Operational safety, technical
rescue routes, at stands 20 safety provisions, technical
safety equipment 7 4.4.1.3 Explosive materials 20 regulations and utilities 32
2.1. Traffic regulations, 4.4.1.4 Pyrotechnics 20 → 5.1 General regulations 32
parking permits 7 4.4.1.5 Balloons 20 5.1.1 Damage 32
2.2 Rescue routes 7 4.4.1.6 Flying objects 20 5.1.2 Coordinating work on the
2.2.1 Fire department manoeuvring → 4.4.1.7 Fog machines, hazers, exhibition grounds
areas, fire hydrants 7 Sparkulars and laser systems 21 5.2 Employment of tools and other
2.2.2 Emergency exits, emergency 4.4.1.8 Ash containers, ashtrays 21 equipment 32
escape hatches, 4.4.1.9 Containers for trash, recyclable 5.3 Electrical installations 32
exhibition hall aisles 7 materials and residual waste 21 5.3.1 Electrical outlets 32
2.3 Safety equipment 8 4.4.1.10 Spray guns, nitrocellulose 5.3.2 Electrical installations on stands 32
→ 2.4 Stand numbering 8 lacquers, cleaning agents, 5.3.3 Installation and operating
2.5 Guard services 8 solvents 21 regulations 33
2.6 Evacuation in an emergency 9 4.4.1.11 Work that poses a fire hazard 22 5.3.4 Safety precautions 33
4.4.1.12 Empty packaging / storage of 5.3.5 Emergency lighting 33
3. Technical data on, and materials 22 5.3.6 Equipotential bonding (stand
equipment of, 4.4.1.13 Fire extinguishers 22 earthing) for metal constructions 33
the exhibition halls and 4.4.1.14 Water features/pools 22 5.4 Water and drain installations 33
outdoor exhibition areas 10 4.4.2 Stand ceilings 22 5.5 Compressed air/gas installation 34
3.1 Hall data 10 4.4.3 Glass and acrylic glass 23 5.5.1 Compressed air installations 34
3.1.1 General lighting, types of electrical 4.4.4 “Trapped rooms” / occupied rooms 23 5.5.2 Gas installations 34
supplies, supply voltages 10 4.5 Exits, escape routes, doors 23 5.6 Machinery, pressure vessels,
3.1.2 Compressed air, electrical and 4.5.1 Exits, escape routes 23 exhaust systems 34
water supplies 10 4.5.2 Doors 23 5.6.1 Noise generated by machinery 34
3.1.3 Communications facilities 10 4.6 Platforms, ladders, stairs, 5.6.2 Product safety 34
3.1.4 Sprinkler systems 10 landings 23 5.6.2.1 Safety equipment 35
3.1.5 Heating, ventilation and 4.7 Stand design 24 5.6.2.2 Inspection procedures 35
air-conditioning 10 4.7.1 Stand appearance 24 5.6.2.3 Prohibition of operation 35
3.1.6 Outages 10 4.7.2 Verification of rented areas 24 5.6.2.4 Additional protective measures 35
3.1.7 Stand air-conditioning 11 4.7.3 Interventions in the structures 5.6.3 Pressure vessels 36
3.2 Outdoor exhibition areas 11 and equipment of buildings 24 5.6.3.1 Certificates of approval 36
3.3 Designation of clear gate heights 11 4.7.4 Exhibition hall floors 25 5.6.3.2 Testing 36
→ 4.7.5 Suspension points/installation of 5.6.3.3 Rental equipment 36
4. Stand construction regulations 12 trusses/fasteners 25 5.6.3.4 Inspections by regulatory 36
4.1 Stand safety 12 4.7.5.1 Electric chain hoists 25 agencies
→ 4.2 Stand construction permits, 4.7.5.2 Manual chain hoists 26 5.6.4 Exhaust gases and vapours 36
project approval 12 4.7.5.3 Fasteners 26 5.6.5 Exhaust systems 36
4.2.1 Inspection and approval of 4.7.6 Stand bounding walls 26 5.7 Employment of compressed
structures requiring a permits 12 4.7.7 Advertising media/presentations 27 gases, liquefied gases and
4.2.2 Vehicles and containers 13 4.7.8 Barrier-free construction 27 combustible liquids 37
4.3 Construction heights 13 4.7.9 Foundations, pits 27 5.7.1 Compressed gas and liquefied
4.4 Fire protection and safety 4.8 Outdoor areas 28 gas systems 37
regulations 14 4.8.1 Stand construction permits/stand- 5.7.1.1 Application for Approval of com-
4.4.1 Fire protection regulations 14 structures requiring approval 28 pressed gas bottles 37
General remarks / Area data 17 4.8.2 Ground anchors/excavations 28 5.7.1.2 Employment of liquefied gases 37
Closed ceilings 17 4.8.3 Weather-related loads 28 5.7.1.3 Installation and maintenance
Stand construction materials, 4.8.3.1 Wind loads 28 of liquefied gas systems 37
stairs 18 4.8.4 Severe weather warnings 28 5.7.2 Combustible liquids 37
Emergency escape routes 18 4.9 Two-storey structures 29 5.7.2.1 Operation requirements 37
Emergency escape route 4.9.1 Requests for approval 29 5.7.2.2 Filling systems with
signage 18 4.9.2 Restrictions applying to stand combustible liquids 37
Wall hydrants 18 superstructures, safety clearances 5.7.2.3 Empty containers 37

2
Technical Guidelines

Contents
→ The items that have been marked contain new changes.

Page Page Page

5.7.3Combustible pastes and other → 5.12 Cranes, forklifts, and empty 6.2.1 Oil/grease traps 44
fuels 37 packings 40 6.2.2 Stand cleaning/cleaning agents 44
5.8 Asbestos and other hazardous 5.13 Musical reproduction 41 6.3 Environmental pollution 44
materials 38 5.14 Beverage dispensing systems 41 6.3.1 Packaging materials 44
5.9 Movie and TV screenings, slide 5.15 Food inspections 41 6.3.2 Kitchen waste 44
shows and other presentations, 5.16 Vehicle and driving demonstra- 6.3.3 Manufacturing wastes 44
stages 38 tions 42 6.3.4 Stand components 44
5.10 Radiation protection 38
5.10.1 Radioactive materials 38 6. Environmental protection 43 7. General information 46
5.10.2 X-ray systems and sources of 6.1 Waste 43 7.1 Limitation of liability 46
broadcast interference 39 6.1.1 Waste disposal 43
→ 5.10.3 Laser systems 39 6.1.2 Hazardous waste 43
5.10.4 LED 39 6.1.3 Waste brought onto the
5.11 High-frequency equipment, radio exhibition grounds 44
systems, electromagnetic 6.2 Water, waste water, soil
compatibility and harmonics 40 protection 44

Appendix

Page

Construction heights 47

3
Technical Guidelines

1. Preliminary remarks

Messe Frankfurt has issued guide- (BauGB). In legal terms, trade fair - Messe München GmbH
lines for trade fairs and other stand constructions are considered - Kölnmesse GmbH
events in order that all exhibitors/ to be “facilities” in the venue. - NürnbergMesse GmbH
event organisers will have optimum In the interest of all participants, - Landesmesse Stuttgart GmbH
opportunities to present their Messe Frankfurt can prohibit the have compiled these Technical
exhibits and attract attendees and holding of an event and/or the Guidelines with a uniform classifi-
interested parties to visit their opening of an exhibition stand if cation system.
stands. defects previously found have not
These guidelines are binding upon been remedied by the start of the In the interests of simpler language
all exhibitors and event organisers. fair. and improved readability, generic
They also incorporate safety regu- Messe Frankfurt retains the right to masculine pronouns have been
lations that are intended to provide issue further safety regulations and used throughout the Technical
high degrees of safety in relation to stand construction standards at Guidelines. These should always
technical and stand equipment in any time. Messe Frankfurt also be understood as referring to per-
the interest of protecting our ex- reserves the right to permit sons of all gender identities.
hibitors and visitors. The building exceptions to these regulations in
provisions, fire protection regulations individual cases. Building codes are issued by the
and other safety regulations in- The documents required to order governments of the respective
volved have been coordinated with services will be sent in due time German states.
the responsible agencies of the before the event. The respective event regulations
City of Frankfurt am Main. These Technical Guidelines must may therefore differ from exhibition
Messe Frankfurt reserves the right be forwarded to all of the exhibi- site to exhibition site due to
to verify compliance with these tor’s contracting partners. differing local building codes and
regulations. Furthermore, the Further information on details of differing construction conditions at
applicable legal regulations, as preparation and staging of the the various exhibition sites.
amended from time to time, shall event will be sent to exhibitors if Messe Frankfurt also reserves the
be observed at all times. applicable. right to modify these Technical
Insofar as the term “stand con- The trade fair companies Guidelines and other regulations at
struction” is used in its convention- - Deutsche Messe AG Hannover any time.
al sense in the Technical Guide- - Leipziger Messe GmbH The German version alone shall be
lines, it does not refer to a physical - Messe Berlin GmbH binding.
structure in the sense of the Ger- - Messe Düsseldorf GmbH
man Federal Building Code - Messe Frankfurt Venue GmbH

4
Technical Guidelines

1.1 Site Regulations

These Site Rules and Regulations observed. Vehicles are subject orders or the conducting of
apply throughout the premises of to a 30 km/h speed limit. surveys, if such activities take
Messe Frankfurt Venue GmbH E-scooters, e-boards and other place outside exhibition
(hereinafter referred to as “Messe similar vehicles may not be stands.
Frankfurt”), including all buildings, used in buildings or in outdoor 7. No commercial activities are
the Rebstock multi-storey car event areas during events. permitted on the exhibition
park, Kap Europa convention cen- 3. Messe Frankfurt shall be enti- grounds unless they are being
tre and all outdoor areas in the tled to search the boots and conducted on behalf of Messe
Rebstock area that are used by cargo areas of vehicles and Frankfurt or an organiser, ex-
Messe Frankfurt (hereinafter re- bags or personal items of indi- hibitor, lessee, service provider
ferred to as the “exhibition viduals at any time regardless or other contracting party that
grounds”). of whether or not there is any has entered into an agreement
Messe Frankfurt and the event or- suspicion of wrongdoing. with Messe Frankfurt.Messe
ganiser each have the right to en- Should anyone refuse permis- Frankfurt reserves the right to
force the Site Rules and Regula- sion, Messe Frankfurt reserves permit or prohibit the activities
tions. Any additional agreements the right to expel them from of third parties acting on be-
reached with exhibitors, service the exhibition grounds. half of contracting parties and
partners etc. remain unaffected. 4. Messe Frankfurt has the right to specify the type, scope and
1. Entrance to the exhibition to issue restrictions on the ad- conditions of their activities.
grounds on foot or in vehicles mission of visitors and to pro- 8. Over-the-counter sales, cash
is only permitted with proper hibit the transport of animals sales, or the acceptance and
and valid authorisation (em- or items onto the exhibition removal of exhibited goods
ployee IDs, service partner IDs, grounds; it may either issue during trade fairs and exhibi-
event-specific admission tick- general provisions or make tions is prohibited. If goods are
ets, set-up and dismantling such restrictions dependent on given away free as samples,
passes) at predefined times the satisfaction of specific re- the exhibitor must provide the
and in the predefined areas of quirements in individual cases. third party with a correspond-
the exhibition buildings and Children and young people un- ing declaration of transfer (re-
grounds. Messe Frankfurt re- der the age of 14 may only en- ceipt). Third parties must de-
serves the right to conduct ter the exhibition grounds in mand a receipt from the
spot checks of individuals to the company of an official exhibitor and must produce
ensure that they are authorised guardian or suitable chaperone this on request.Should any
to be on the exhibition 5. Messe Frankfurt accepts no li- such third party be found with-
grounds, regardless of wheth- ability whatsoever for any per- out a receipt, Messe Frankfurt
er they are suspected of sonal injury, property damage reserves the right to impound
wrongdoing. or financial loss that might oc- the goods without compensa-
2. The provisions of the German cur at the exhibition grounds tion and expel the third party
Road Traffic Regulations 6. Unless Messe Frankfurt has from the exhibition grounds.
(StVO) are applicable for every- given express permission, it 9. Devices that can be used to
one on the exhibition grounds. does not allow advertising of produce photos or film are pro-
All signs regulating vehicular any kind, neither does it permit hibited throughout the exhibi-
and pedestrian traffic on the the offer of goods or services tion grounds. Filming, taking
exhibition grounds must be of any kind, the acceptance of pictures and making sketches

5
Technical Guidelines

1.1 House Rules

of exhibited goods on the exhi- reasons. rary or permanent ban on their


bition grounds and in the exhi- 11. There is a general smoking ban return, as well as to confiscate
bition halls is only permissible in all buildings and enclosed their access documents with-
in exceptional cases with the rooms within the exhibition out compensation, and to have
written consent of Messe grounds. any vehicles removed from the
Frankfurt. If there is reasonable 12. Instructions given by Messe premises at the expense an-
suspicion, Messe Frankfurt is Frankfurt security staff and drisk of the owner or operator.
entitled to confiscate any stewards must be followed at 14 A limited road and walkway
sketches, photographs or other all times. clearance service is provided
film materials that have been 13. In the event that the House during the winter months. This
made and have these de- Rules or other requirements applies for both the restricted
stroyed without providing and regulations are violated, and the publicly accessible ar-
compensation. This also ap- access documentation is mis- eas of the Messe Frankfurt ex-
plies if other film or photo- used or forged, or there is oth- hibition grounds
graphic material will be de- er disruptive behaviour, Messe
stroyed as a result. Frankfurt reserves the right to As at: November 2020
10. It should be noted that the ex- expel those responsible from
hibition grounds are under vid- the exhibition buildings and
eo surveillance for security grounds and to issue a tempo-

1.2 Opening hours

1.2.1 Set-up and dismantling tures and structures built into of dismantling periods.
periods stands, shall have been concluded In the interest of general safety, all
In general, stand building and de- and the exhibition hall vacated no exhibition halls and the exhibition
liveries of exhibited goods may later than the second calendar day grounds shall
commence five (5) calendar days following the close of the event in- remain closed outside official
prior to the opening of the event volved. The exhibitor and any stand set-up and dismantling periods and
involved. construction companies they work event opening hours.
During the general set-up and with should report to the service
dismantling periods, work in the office responsible for the hall both 1.2.2 Opening hours during
exhibition halls and on the outdoor at the start of stand set-up and at trade fairs/exhibitions
exhibition areas may proceed the end of dismantling. Stand are- Exhibition halls shall be opened
around the clock, that is, 24 hours as shall be swept and returned in a one hour prior to the official opening
per day (normally no work may be clean condition. In special cases, of the trade fair and shall be closed
performed after 3 p.m. on the final Messe Frankfurt Venue GmbH’s one hour after it closes, on every
days of set-up periods, however), Technical Project Management day the event involved is officially
unless other hours and a schedule may grant extensions of set-up open.
of working hours have been and/or dismantling periods. Exhibi- Exhibitors who, in special cases,
announced for a particular event. tion halls are neither heated nor have valid grounds for working on
In general, dismantling of stand air-conditioned prior to the official their stands outside said opening
equipment and furnishings, includ- commencement of set-up periods hours shall require special written
ing exhibitors’ own stand struc- or following the official termination permits issued by Messe Frankfurt.

6
Technical Guidelines

2. Traffic on the exhibition grounds, rescue routes, safety equipment

2.1 Traffic regulations, parking permits

All rules directing and regulating speed. Engines must be turned off Driving any type of vehicle on the
traffic, such as those described in during loading/unloading. Before exhibition grounds requires a per-
the Traffic regulations, and all in- entering/exiting exhibition halls, mit from Messe Frankfurt, is at
structions given by the personnel drivers must come to a full stop drivers’ own risk, and is prohibited
deployed by Messe Frankfurt for and ensure that gates offer suffi- at all times during events.
this purpose, shall be observed at cient overhead clearance. Parking There is a limited number of car
all times. vehicles in the exhibition halls is parking spaces available for exhibi-
The exhibition grounds are the pri- prohibited. Caravans/campers may tors on the exhibition grounds. In
vate property of Messe Frankfurt. not be used on the exhibition accordance with the number of
The provisions of the StVO (German grounds. spaces available, parking permits
road traffic regulations) apply Illegally parked vehicles, trailers, can only be ordered for the entire
throughout the exhibition grounds containers, and goods of any kind duration of the event using the cor-
and on/in Messe Frankfurt’s parking may be removed by authorised responding form (please also see
facilities. The speed limit on the towing companies working under the Transport Guidelines).
exhibition grounds is 30 km/h. contract to Messe Frankfurt at their
If called for by traffic conditions, owners’ or operators’ expense and
vehicles must not exceed walking risk.

2.2 Rescue routes

2.2.1 Fire department possible to easily open the doors structing stands or exhibits deliv-
manoeuvring areas, fire hydrants along escape and rescue routes ered for immediate installation at
The necessary fire-department entry from the inside to their fully open the stand area may be deposited in
routes and manoeuvring areas des- position. Escape and rescue the escape and rescue routes for a
ignated by “no-parking” signs routes, exit doors, emergency exits short period of time during the set-
must be kept clear at all times. and their identifying signs or mark- up and dismantling phases as long
Vehicles or objects parked/deposited ings must not be obstructed, ob- as the aisle widths required for
in rescue routes or on safety areas scured, have anything built over safety reasons are maintained and
shall be removed at their owners’ them, be blocked, have anything logistical concerns are sufficiently
expense and risk. hung on them or otherwise be ren- taken into consideration. This will
Fire hydrants in the exhibition halls dered unrecognisable. Escape and be considered to be fulfilled if a
and on outdoor exhibition areas rescue routes in exhibition halls strip of no more than 0.9 m in
shall not be obstructed or rendered shall not be constricted by objects width between the stand border
unrecognisable or inaccessible. deposited therein or extending into and the hall aisle is used to deposit
them at any time. In the event that items. Regardless of the width of
2.2.2 Emergency exits, these rules are not complied with, the hall aisle and the items depos-
emergency escape hatches, Messe Frankfurt shall be entitled to ited there, it is mandatory to main-
exhibition hall aisles remedy the situation at the ex- tain an unblocked passageway of
Escape and rescue routes shall be pense and risk of the responsible no less than 1.2 m in width. Areas
kept clear at all times. It must be party. Materials required for con- in front of emergency exits and ar-

7
Technical Guidelines

2.2 Rescue routes

eas where hall aisles intersect are bly or to set up machines (e.g. clearing of all hall aisles for logisti-
the exception: their entire width woodworking equipment, work- cal reasons.
must be kept clear at all times. Hall benches etc.). Messe Frankfurt
aisles may not be used for assem- may (also) request the immediate

2.3. Safety equipment

Sprinkler systems, fire alarms, fire hall doors and other items of safety shall remain visible and accessible
extinguishers, smoke detectors, equipment, their signs or markings, at all times, and shall not be obst-
mechanisms for closing exhibition and green emergency exit signs ructed or enclosed.

2.4. Stand numbering and aisle designations

Stand numbering and corresponding adopt the existing aisle designation cept to Technical Project
aisle designations are obligatory for system that is normally used in Management for approval. This
safety reasons. All stands will be Frankfurt. could make it necessary to modify or
marked with stand numbers by the If the organiser wishes to use differ- replace the existing escape route sig-
organiser. ent designations, they must first pre- nage, which would entail an addi-
We recommend that organisers sent an alternative aisle signage con- tional fee.

2.5. Guard services

Messe Frankfurt and Messe Frank- Exhibitors are expressly informed be arranged by the exhibitor where
furt’s external service partners that exhibited materials and other necessary.
monitor the exhibition halls and objects brought by the exhibitors
outside areas during the set-up are subject to greater risk during As a general rule, stand guards
and dismantling phases, as well as set-up and dismantling periods. may only be posted between 6:00
while events are underway. How- Valuable and easily moveable ob- p.m. and 8:00 a.m. by Messe
ever, Messe Frankfurt accepts no jects should always be locked Frankfurt or its contractual service
responsibility for property and ob- away at night. partner(s). Exhibitors may order
jects brought or delivered by exhib- stand guards no later than six
itors and third parties acting under Security for the stand and the ob- weeks before the start of the event
Messe Frankfurt’s instructions. jects brought by the exhibitor must with the corresponding order form

8
Technical Guidelines

2.5. Guard services

(please refer to the service folder or prior to, during and after events the shortest route passing by the
go to Shop for Exhibitor Services shall also observe the following hall inspector’s office. In the event
online). Ordering stand guards in- regulations: Guards shall sign in at that they fail to observe these reg-
volves submitting a fully complet- the hall inspector’s office prior to ulations, Messe Frankfurt shall as-
ed, preprinted order form for the going on duty. Their presence on sume that the presence of that per-
event involved. Oral or telephone site shall be confirmed by entering son on the stand or in the
orders for stand guarding must be their name, the name of the exhibi- exhibition hall is unauthorised and
confirmed in writing by applicants. tor, the stand number, the number reserves the right to institute spe-
All orders for stand guarding must of their personal identification card cial measures, to expel that person
be signed by applicants. Messe or passport number, and the date from the exhibition grounds, and/
Frankfurt service personnel is not and time of their arrival on a list or to file other claims or claim
authorised to assume responsibility provided for that purpose and damages. Bringing guard dogs
for monitoring for third-party prop- maintained by the hall inspector’s onto the exhibition grounds re-
erty. Exhibitors’ own stand security office. Upon concluding their peri- quires a permit issued by Messe
staff who are to remain on duty in od of duty, and before leaving the Frankfurt that may be revoked by
exhibition halls between 6 p.m. exhibition hall, stand security staff same at any time. Dogs shall be
and 8 a.m. require special permits shall sign out at the hall inspector’s kept on a leash at all times. Weap-
for which a fee is charged. Exhibi- office and note the termination of ons may not be brought onto the
tors have no legal rights to demand their period of duty on the afore- exhibition grounds, even for guard-
issuance of such permits. mentioned list. Stand security staff ing purposes.
shall remain on that stand for
Exhibitors’ own stand security staff which they have a guarding order,
who are present in exhibition halls and shall enter and leave stands by

2.6. Evacuation in an emergency

For safety or security reasons,


Messe Frankfurt may order the clo-
sure and evacuation of rooms,
buildings or outdoor areas.

9
Technical Guidelines

3. Technical data on, and equipment of, the exhibition halls and outdoor exhibition areas

3.1 Hall data

Since the technical data on the var- installation channels and connection mentioned rules and regulations
ious exhibition halls differ from hall points in hall floors. are also applicable for WiFi trans-
to hall, they have been listed in a On exhibition hall floors having mitters in exhibits. The operation of
separate document (cf. the docu- supporting columns, connection WiFi networks that cause interfer-
ment entitled “Technical Data on points are also available at terminal ence or disruption is prohibited.
the Exhibition Halls of Messe boxes mounted on these supporting Messe Frankfurt reserves the right
Frankfurt”). columns. to shut down these networks.
Guidelines for the operation of ex- Forms for registering your own ac-
3.1.1 General lighting, types hibitors’ own WiFi networks at cess point are available at www.
of electrical supplies, supply Messe Frankfurt: Exhibitors’ own messefrankfurt.com. Exhibitors’
voltages WiFi transmitters may only trans- own WiFi transmitters must be
The general lighting in the exhibition mit in the 2.4 GHz band in accord- registered in good time before a
halls differs from hall to hall, and ance with currently applicable trade fair in order to ensure that
ranges from around 300 lux to standards (802.11 b/g/n); transmis- these rules are complied with by all
around 400 lux, measured one me- sion in the 5 GHz band is prohibit- exhibitors.
ter above floor level. The electrical ed! The 5 GHz band is reserved ex-
supplies and supply voltages avail- clusively for Messe Frankfurt in 3.1.4 Sprinkler systems
able on the exhibition grounds are order to allow for the provision of Exhibition halls are equipped with
as follows: exhibitor-specific solutions. As a sprinkler systems.
Network type: TN-C-S result, WiFi transmitters may only Exhibits and decorations must be
Supply voltage: 230 V / 400 V transmit on channels 1, 6 or 11, and situated at least 1.0 m from sprinkler
Tolerances as per DIN EN 50160 cannot be configured for automatic heads. Distances between lamps/
channel search. Channel bonding spotlights and sprinkler heads
3.1.2 Compressed air, electrical is not permitted, and the maximum should be chosen so as to preclude
and water supplies channel bandwidth is 20 MHz. The false triggerings of fire extinguishing
The compressed air, electrical and maximum transmission power of devices through the heat generated
water supplies on stands located in the exhibitor’s transmitter may not by the lighting.
exhibition halls are routed through exceed -80 dBm at the edge of the
existing installation channels to stand. The SSID, i.e. your access 3.1.5 Heating, ventilation and
connection points in hall floors. point ID, must begin with your air-conditioning
On exhibition hall floors having stand number (e.g. H4.0 B42). All All halls are equipped with heating,
supporting columns, electrical sup- of the aforementioned settings can ventilation and air-conditioning
plies are also available at terminal be made using the access point systems. These systems will be
boxes mounted on these supporting configuration menu. Any transmit- operational as required throughout
columns. ters other than WiFi transmitters events.
are prohibited, as they can cause
3.1.3 Communications facilities massive disruption to signals. In 3.1.6 Outages
Stands located in exhibition halls the event that exhibits require dif- Messe Frankfurt should be notified
are supplied with telephone, fax, ferent transmitters, please contact immediately in the event of any
data and antenna lines via existing us in advance. Naturally the afore- outages of utilities, such as elec-

10
Technical Guidelines

3.1 Hall data

tricity, water, compressed air, heating, 3.1.7 Stand air-conditioning vidual offer. It is not permitted to
ventilation or telecommunications It is possible to individually air-con- use drinking water to flow-cool
systems, etc. Messe Frankfurt as- dition stand areas. Messe Frank- stands.
sumes no liability for any losses or furt’s Exhibitor Service would be
damage due to such outages. happy to provide you with an indi-

3.2. Outdoor areas

Outdoor areas are paved with as- the onset of darkness during event Please also be sure to note Item
phalt or stones. The grounds have opening hours. Necessary utilities 4.8 “Outdoor areas” when con-
general road and walkway lighting connections are spaced at irregular ducting your planning.
systems that will be activated at intervals.

3.3. Designation of clear gate heights

Gates having clear heights less


than 4.00 m are designated by
signs.

11
Technical Guidelines

4. Stand construction regulations

4.1 Stand safety

Exhibition stands – including fur- decorative elements) which might ance is to be compiled in advance
nishings, exhibits and advertising tip over must be designed to with- and presented to Messe Frankfurt
media – must be structurally stable stand the following equivalent dis- on request (see Item 4.2.1). Devia-
to ensure that there is no threat to tributed lateral loads qh: tions are possible in justified ex-
public safety and order, and in qh1 = 0.125 kN/m² up to 4 m in ceptional cases and require de-
particular that there is no danger height measured from the top of tailed documentation.
to life or health. The exhibitor is the floor Bracing stands against neighbour-
responsible for the structural safety qh2 = 0.063 kN/m² for all areas ing stands or existing building
of their stands, and may be re- more than 4 m high measured structures is prohibited.
quired to submit proof of same. from the top of the floor In justified cases, Messe Frankfurt
Standing constructional elements The reference area is the respec- reserves the right to engage a
or special constructions (e.g. free- tive surface area. structural engineer to conduct a
standing walls, high exhibits, high Verifiable/verified proof of compli- chargeable verification of stand
stability on site.

4.2 Stand construction permits, project permission

Permits are not required for the be invoiced to the exhibitor / suitable scale (e.g. 1:100), labelled in
following: stand constructor. English or German, accompanied by
For single-storey stands floor plans (as well as sectioned
- that are not considered to be Special constructions include: views and perspective views if ap-
special constructions –S tand structures and exhibits propriate), shall be submitted in digi-
- whose stand area is no more that are more than 4 metres in tal form (PDF) for approval by no lat-
than 100 m² height er than six weeks before the start of
- whose height does not exceed – Closed ceilings set-up to
4.00 m –P latforms and stages higher standapproval@messefrankfurt.com.
it is not necessary to submit plan- than 0.20 m After the stand plans have been in-
ning documents. – Glass constructions spected, one copy will be stamped
– Moving components as having received permission and
Permits are required for the – Floor/ceiling connections returned to the exhibitor / stand con-
following: structor if accepted. Stand construc-
Exhibition stands larger than 100 Installations in rented rooms are tion may not commence until the
m² in area, stands located in out- also subject to approval. plans have been stamped as having
door areas, temporary structures, The planning documents must be received permission. In order to re-
mobile stands, two-storey stands, submitted accordingly. ceive permission for the following:
special structures and special con- – Special constructions
structions require consent and in- 4.2.1 Inspection and permission – Two-storey structures
spection, and are subject to addi- for structures requiring a permit – Stands in outdoor areas
tional cost. Any costs incurred will Dimensioned stand plans drawn to a – Temporary structures

12
Technical Guidelines

4.2 Stand construction permits, project permission

– Cinemas and auditoriums lengths and widths of emergency Due to the additional work en-
– Stages and platforms escape route(s) tailed, the absence of structural
the following documentation must e) Submission of a type certifica- calculations results in additional
be submitted in digital form (PDF) tion / certification book renders costs for the exhibitor / stand con-
in German or English by no later item a) superfluous structor.
than six weeks before the start of In the event that structural calcu-
set-up: lations examined by a second, in- 4.2.2 Vehicles and containers
a) Structural calculations comply- dependent structural engineer are Vehicles and containers that are to
ing with German building stand- not submitted, Messe Frankfurt be employed as exhibition stands
ards that are checkable or have will commission a firm of engi- in exhibition halls or outdoor areas
been checked by a second inde- neering consultants to check the require permission.
pendent structural engineer plans and separately invoice the
b) A building description specify- exhibitor / stand constructor for
ing the materials used (including their services. The firm of engi-
certificates in German or English neering consultants will contact
where applicable) the stand construction manager at
c) Stand construction drawings to a specified time / after consulta-
a suitable scale, e.g. 1:100 (floor tion to provide assistance and ex-
plans, perspective views, sec- amine structural characteristics,
tioned views) as well as a ceiling and to inspect the structure for a
plan with dimensions of the fee.
closed ceiling(s)
d) Escape route plan including

4.3 Construction heights

The maximum construction heights neighbouring stand. There may be eas must be at least 2.30 m. The rear
for stands, rigging and advertising special restrictions in particular halls. sides of stands adjacent to neigh-
can be found at www.messefrank- All measurements must be checked bouring stands must be kept smooth
furt.com. Advertising media, logos, on site and Messe Frankfurt as- and be white in colour from a height
etc., must be positioned at least 1 sumes no liability for figures being of 2.50 m. Deviations are only possi-
metre from the border with the correct. The clear height of inside ar- ble with the agreement of neigh-
bouring stands.

13
Technical Guidelines

4.4 Fire protection and safety regulations

4.4.1 Fire protection regulations systems be impaired by stand con- consult the following Tables 1 and
The use of open fires and flames is structions (e.g. closed ceilings), ex- 2 for the necessary measures.
prohibited. Exhibition halls are hibitors must undertake additional Closed ceilings are not permitted in
equipped with fire alarms and fire measures in agreement with Mes- foyers.
extinguishing systems. Should the se Frankfurt Venue GmbH’s Techni-
operation of these fire protection cal Project Management. Please

14
Technical Guidelines

4.4 Fire protection and safety regulations


Table 1: Fire protection programme for one-storey exhibition stands with closed GF ceilings and two-storey exhibition stands with
open TF ceilings (GF = ground floor, TF = top floor)

Ceiling area 0 - 30 m² 31 - 100 m² 101 - 200 m² 201 - 400 m² 401 - 1000 m²


above the ground floor

Fire protection measures

Stand construction- Minimum B1, Minimum B1, Minimum B1, Minimum B1, Minimum B1,
materials incl. ceilings flame retardant flame retardant flame retardant flame retardant flame retardant
Stairs Minimum B1, Minimum B1, Minimum B1, Minimum B1, Minimum B1,
flame retardant flame retardant flame retardant flame retardant flame retardant

Emergency escape GF: GF: GF: GF: GF:


route length max 20 m to aisle max 20 m to aisle max 20 m to aisle max 20 m to aisle max 20 m to aisle
TF: TF: TF: TF: TF:
max 20 m to aisle max 20 m to aisle max 20 m to aisle max 20 m to aisle max 20 m to aisle

Exits from exhibition GF: one; 0.9 m GF: one; 0.9 m GF: Two, opposite one an- GF: Two, opposite one an- GF: Two, opposite one an-
stands or from rooms TF: one flight of TF: one flight of other, other, other,
located on stands stairs; 0.9 m stairs; 0.9 m < 200 m2: 0.9 m < 200 m2: 0.9 m < 200 m2: 0.9 m
(minimum width) > 200 pers: min. 1.2 m + 0.6 m > 200 pers: min. 1.2 m + 0.6 m > 200 pers: min. 1.2 m + 0.6 m
for each additional 100 pers. for each additional 100 pers. for each additional 100 pers.
TF: Two flights of stairs oppo- TF: Two flights of stairs oppo- TF: Two flights of stairs oppo-
site one another, each < 200 site one another, each < 200 site one another, each < 200
m2: 0.9 m m2: 0.9 m m2: 0.9 m
> 200 pers: min 1.2 m + 0.6 m > 200 pers: min 1.2 m + 0.6 m > 200 pers: min 1.2 m + 0.6 m
for each additional 100 pers. for each additional 100 pers. for each additional 100 pers.

Emergency escape Yes Yes Yes Yes Yes


route signage Escape sign lights Emergency lighting Emergency lighting Emergency lighting

Fire extinguishers GF: Yes GF: Yes GF: Yes GF: Yes GF: Yes
TF: Yes 1+1 p. stairs TF: Yes 1+1 p. stairs TF: Yes 1 + 1 per stairs TF: Yes 1 + 1 per stairs TF: Yes 1 + 1 per stairs

Fire alarm system GF: No GF: Yes GF: Yes GF: Yes GF: Yes
TF: No TF: No TF: No TF: No TF: No

Acoustic/visual alarm GF: No GF: No GF: No GF: No GF: Yes


TF: No TF: Yes TF: Yes TF: Yes TF: Yes

Wall hydrant ”S“ GF: No GF: No GF: Yes, one GF: Yes, two GF: Yes, three
at stand TF: No TF: No TF: No TF: No OG: Yes, three

Smoke removal GF: No GF: No GF: No GF: Yes GF: Yes


TF: No TF: No TF: No TF: No TF: No

Sprinkling GF: No GF: No GF: No GF: No GF: Yes


TF: No TF: No TF: No TF: No TF: No

Please note: If there is no top storey used by people, the corresponding requirements for the top storey do not apply.
15
Technical Guidelines

4.4 Fire protection and safety regulations

Table 2: Fire protection programme for two-storey exhibition stands with closed GF ceilings and closed TF ceilings (GF = ground floor,
TF = top floor)

Ceiling area 0 - 30 m² 31 - 100 m² 101 - 200 m² 201 - 400 m² 401 - 1000 m²


above the top floor

Fire protection measures


Stand construction- Minimum B1, Minimum B1, Minimum B1, Minimum B1, Minimum B1,
materials incl. ceilings flame retardant flame retardant flame retardant flame retardant flame retardant

Stairs Minimum B1, Minimum B1, Minimum B1, Minimum B1, Minimum B1,
flame retardant flame retardant flame retardant flame retardant flame retardant

Emergency escape GF: GF: GF: GF: GF:


route length max 20 m to aisle max 20 m to aisle max 20 m to aisle max 20 m to aisle max 20 m to aisle
TF: TF: TF: TF: TF:
max 20 m to aisle max 20 m to aisle max 20 m to aisle max 20 m to aisle max 20 m to aisle

Exits from exhibition GF: one; 0.9 m GF: one; 0.9 m GF: Two, opposite one an- GF: Two, opposite one an- GF: Two, opposite one an-
stands or from rooms TF: one flight of TF: one flight of other, other, other,
located on stands stairs; 0.9 m stairs; 0.9 m < 200 m2: 0.9 m < 200 m2: 0.9 m < 200 m2: 0.9 m
(minimum width) > 200 pers: min. 1.2 m + 0.6 m > 200 pers: min. 1.2 m + 0.6 m > 200 pers: min. 1.2 m + 0.6 m
for each additional 100 pers. for each additional 100 pers. for each additional 100 pers.
TF: Two flights of stairs oppo- TF: Two flights of stairs oppo- TF: Two flights of stairs oppo-
site one another, each < 200 site one another, each < 200 site one another, each < 200
m2: 0.9 m m2: 0.9 m m2: 0.9 m
> 200 pers: min 1.2 m + 0.6 m > 200 pers: min 1.2 m + 0.6 m > 200 pers: min 1.2 m + 0.6 m
for each additional 100 pers. for each additional 100 pers. for each additional 100 pers.
Emergency escape Yes Yes Yes Yes Yes
route signage Escape sign lights Emergency lighting Emergency lighting Emergency lighting

Fire extinguishers GF: Yes GF: Yes GF: Yes GF: Yes GF: Yes
TF: Yes 1+1 p. stairs TF: Yes 1+1 p. stairs TF: Yes 1 + 1 per stairs TF: Yes 1 + 1 per stairs TF: Yes 1 + 1 per stairs

Fire alarm system GF: No GF: Yes GF: Yes GF: Yes GF: Yes
TF: No TF: Yes TF: Yes TF: Yes TF: Yes

Acoustic/visual alarm GF: No GF: No GF: No GF: No GF: Yes


TF: No TF: Yes TF: Yes TF: Yes TF: Yes

Wall hydrant ”S“ GF: No GF: No GF: Yes, one GF: Yes, two GF: Yes, three
at stand TF: No TF: No TF: Yes, one TF: Yes, two TF: Yes, three
Smoke removal GF: No GF: No GF: No GF: Yes GF: Yes
TF: No TF: No TF: No TF: Yes TF: Yes

Sprinkling GF: No
TF: No GF: No GF: No GF: No GF: Yes
TF: No TF: No TF: No TF: Yes

16
Technical Guidelines

4.4 Fire protection and safety regulations

Explanations for Table 1 and 2 Fire protection measures: neath the closed ceiling. It is
- Up to 30 m² of ceiling area of not permissible to place multiple
General remarks / Area data each stand may be covered ceiling areas of up to 400 m²
Two-storey structures and the in- without any additional meas- next to one another without a
stallation of closed ceilings are only ures being necessary as long as sprinkler system. A minimum
possible with the consent of Messe this does not exceed 50% of distance of 5 m (straight line)
Frankfurt Venue GmbH’s Technical the stand area, because this must be maintained between
Project Management. does not reduce the effective- the ceiling areas.
Area data in m² refers in each case ness of the sprinkler system in Should a larger ceiling area result
to the closed ceiling area per sto- the exhibition hall. It is also from not observing the minimum
rey; a rating in sections may be possible to have multiple ceil- distance, including across multiple
necessary. For stands with closed ing areas of up to 30 m² within stands, the expenses incurred for
ceilings measuring 1,000 m² or a single exhibition stand, as compensatory measures according
over, an individual fire protection long as a minimum distance of to Table 1 or 2 will be billed to
concept based on the Messe 3.00 m is maintained between those who caused them, including
Frankfurt Technical Guidelines each ceiling area. In order to expenses for the affected neigh-
must be prepared and submitted to ensure that multiple ceiling ar- bouring stand.
Messe Frankfurt for its consent. eas taken together do not ex-
ceed the maximum size of 30 The top storey must always be left
Closed ceilings m², a distance of at least 1.50 m open to ensure that the effective-
The effectiveness of the sprinkler from the edge of the stand is to ness of sprinkler systems is not im-
system (in the exhibition hall) must be maintained at all times. paired. If the ceilings of top storeys
not be reduced by covered or multi- - Closed ceiling areas up to 100 m² are closed, additional requirements
storey exhibition stands. in size require an automatic fire set out in Table 2 shall apply.
Ceilings are considered to be open: alarm system. Please also see Item 4.4.2. Closed
- if no more than 50% per each - Closed ceiling areas that are ceilings are not permitted in foyers.
m² of the roofed area is covered larger than 100 m² in size also
- if sprinkler-compatible fabrics require the installation of wall
with a minimum mesh width of hydrants for immediate fire-
2 mm x 4 mm or 3 mm x 3 mm fighting measures
are used (no Smoke Out). Tar- - Closed ceiling areas that are
paulins are to be hung horizon- 401 m² or larger require a sprin-
tally and only in one layer. kler system for the area be-

17
Technical Guidelines

4.4 Fire protection and safety regulations

Further general explanations: emergency lighting and safety sig- within a stand. For stands without
nage must be provided for exits closed ceilings measuring up to 30
Stand construction materials, and emergency escape routes (cf. m², a can of fire extinguishing
stairs Section 15 H-VStättR). For stands spray with an extinguishing capaci-
All stand construction and decora- with an enclosed area of 30-100 m², ty of at least 8 A (2 extinguishing
tive materials must at least be clas- illuminated emergency exit signs units pursuant to the extinguishing
sified as flame-retardant class B1 in are sufficient. agent table ASR A2.2) can serve as
accordance with DIN 4102 and/or an alternative to a fire extinguisher.
class C s2 d2 in accordance with Wall hydrants The fire extinguishers must have
EN 13501-1. Stricter requirements Additional wall hydrants at exhi- an extinguishing capacity of at
apply in particular for materials bition stands are to be provided least 27 A for fire classification A
that are used for ceiling structures primarily for self-help, but also or 144 B for fire classification B and
or overhead: they must not only be for use by instructed persons. should not weigh more than 12 kg.
flame-retardant, but also must not Wall hydrants for self-help com- Suitable fire extinguishers must be
drip while burning. This corre- ply with DIN 14461 Part 1 Type provided if stands have kitchens.
sponds to class C s2 d0 in accord- “S” and are to be marked with an Exhibitors must label fire extin-
ance with EN 13501-1. For floor “S” accordingly, in addition to guishers with their stand number
coverings, class C fl s1 is required. safety marking. The capacity of and exhibitor name to ensure that
For safety reasons, special require- the wall hydrants for self-help is they can be properly assigned to
ments may be imposed for load- 24 l/min with simultaneous oper- the correct stand areas.
bearing structural components in ation of two wall hydrants with
individual cases. All stairways must non-distorting hoses of 19 mm in Fire alarm system
comply with DIN 18065. diameter and a jet pipe with The automatic fire alarm systems
mouthpiece of 4 mm in diameter. on exhibition stands with closed
Emergency escape routes Wall hydrants at exhibition stands ceilings are designed to detect a
The routing and dimensioning of are to be installed in the direct fire at an early stage and to warn
emergency escape routes are gov- vicinity of stand entrances or, re- both stand visitors, especially
erned by the requirements of spectively, at the top or bottom of those on the top floor of a stand,
H-VStättR (Hessian guidelines on stairs. Wall hydrants are to be lo- and the fire service. In this way, the
public meeting places).Distances cated such that every covered conditions for escape are signifi-
within exhibition stands shall be part of an exhibition stand can be cantly improved and fire service
measured according to walking reached with at least one wall hy- intervention times minimised. As
distance. drant. Stand personnel will be in- well as warning facilities, systems
structed in use of the wall hy- for smoke removal can be activated
Emergency escape route signage drants by Messe Frankfurt. by an automatic fire alarm system.
Escape routes, emergency exits,
emergency escape hatches and Fire extinguishers Acoustic/visual alarm
doors along emergency escape Every level of an exhibition stand An acoustic/visual warning system
routes must be identified in ac- must be equipped with at least one must be installed on the top floor
cordance with the provisions of fire extinguisher appropriate to the of two-storey exhibition stands if
ASR A1.3 “Health and Safety existing fire risk. One additional fire there is no visual contact with the
Signage”. In the event that stands extinguisher must be provided for exhibition hall. In this way, people
are enclosed or darkened and the each further 200 m². An additional on the top storey can be warned at
general emergency lighting for the fire extinguisher must be provided an early stage if there is a fire
exhibition hall is not sufficient, at the top of each flight of stairs alarm on the ground floor. The

18
Technical Guidelines

4.4 Fire protection and safety regulations

warning system is activated/trig- elements either. A mechanical cordance with DIN 4102 and/or
gered by the automatic fire alarm smoke removal system is triggered/ class C s2 d2 in accordance with
system on the ground floor of a activated via the automatic fire EN 13501-1. Stricter requirements
two-storey stand. For exhibition alarm system. apply in particular for materials that
stands with closed ceilings larger are used for ceiling structures or
than 400 m2, a warning system of Sprinkler systems overhead: they must not only be
this type must be provided on the Closed ceiling areas that are larger flame-retardant, but also must not
ground floor too. than 400 m² require a sprinkler sys- drip while burning. This corre-
Soundproof booths must addition- tem for the area beneath the closed sponds to class C s2 d0 in accord-
ally – irrespective of their size – ceiling. ance with EN 13501-1. For floor cov-
either allow visual contact to the It is not permissible to place multiple erings, class C fl s1 is required. Test
outside or feature an acoustic/visual ceiling areas of up to 400 m² next to certificates stating the classifica-
signal system combined with an one another without a sprinkler sys- tions of the building materials em-
alarm button or an emergency tem. A minimum distance of 5 m ployed shall be kept available at the
switch outside the booth. (straight line) must be maintained stand at all times.
between the ceiling areas. All materials brought on site must
Smoke removal Should a larger ceiling area result be kept at a sufficient distance from
Smoke removal from exhibition from not observing the minimum ignition sources, spotlights and heat
stands is by natural means or distance, including across multiple sources to ensure that they cannot
mechanically into the exhibition stands, the expenses incurred for be ignited. Decorations must be
hall and from there by natural compensatory measures according mounted directly on walls, ceilings
means or mechanically to the out- to Table 1 or 2 will be billed to those or furnishings. Decorations sus-
side. No smoke extraction system is who caused them, including expens- pended (freely) within the room are
required for exhibition stands with a es for the affected neighbouring only permissible if they are at least
ceiling area of less than 200 m2. stand. 2.5 metres above the floor and do
For stands with a ceiling area of up not impede the effectiveness of au-
to 1,000 m2, smoke removal open- 4.4.1.1 Stand construction and tomatic fire extinguishing systems.
ings with clear opening space decorative materials The rear of backlit areas/walls and
totalling 1 percent of the stand Materials that are flammable, drip LED walls must remain accessible
area, windows or doors with clear while burning or generate toxic to the fire brigade without the use
opening space totalling 2 percent gases or large amounts of smoke, of tools.
of the stand area or a mechanical such as most thermoplastics (in- Bamboo, reed, hay, straw, bark
smoke extraction system with an cluding polystyrene (styrofoam)), mulch, peat or similar materials do
air volume flow rate of 36 m3/h per cannot be used for stand construc- not generally satisfy the aforemen-
square metre of stand area are tion. For safety reasons, special tioned requirements, and should
considered adequate. No require- requirements may be imposed for generally be afforded special pro-
ments relating to maintenance of load-bearing structural components tection or treated to render them
thermal and electrical functions in individual cases (e.g. non-flam- non-flammable. Deciduous and co-
apply to systems for mechanical mable). Attachments that are struc- niferous trees may only be used if
smoke removal from exhibition turally necessary or load-bearing their roots are kept moist at all
stands, since such smoke removal can only be made using non-flam- times.
is only relevant in the self-help mable fasteners and materials. All The use of artificial plants is not per-
phase and possibly for giving help stand construction and decorative mitted unless they are demonstra-
to third parties and no requirements materials must at least be classified bly certified by the manufacturer as
are prescribed for exhibition stand as flame-retardant class B1 in ac- at least flame retardant B1 accord-
ing to DIN 4102 or correspondingly

19
Technical Guidelines

4.4 Fire protection and safety regulations

at least C s2 d2 according to EN battery contacts such that they are kept at the stand, and are also to be
13501-1. safe to touch, and the starter re- submitted to Messe Frankfurt in ad-
Higher requirements apply in par- mains disconnected from the bat- vance.
ticular to artificial plants used over- tery). Messe Frankfurt Venue GmbH re-
head: In addition to flame retardan- - The battery is to be disconnected serves the right to require additional
cy, there is a requirement here for or removed in all other cases. measures.
non-flammability dripping. Accord- Vehicles with alternative fuels, e.g.
ing to EN 13501-1, this corresponds liquefied petroleum gas (LPG), nat- 4.4.1.3 Explosive materials
to classification C s2 d0. ural gas or hydrogen Explosive materials are subject to
Attachments that are structurally - The volume of fuel should be limit- the German Explosives Act
necessary can only be made using ed to the minimum necessary (the (Sprengstoffgesetz), and may not
fasteners approved for this purpose fuel warning light must be active). be exhibited at trade fairs or exhibi-
(e.g. plastic cable ties are prohibit- Vehicles with alternative drive tions. The same applies to ammuni-
ed!). technologies, e.g. electrically-pow- tion in the sense of the German
The use of candles and similar ered vehicles or hybrid vehicles Firearms Act (Waffengesetz).
sources of light as table decora- - The fuel tank must be locked and
tions is permissible with the con- nearly empty. 4.4.1.4 Pyrotechnics
sent of Messe Frankfurt Venue - The drive motor must be discon- Pyrotechnic shows must be regis-
GmbH’s Technical Project Manage- nected from the battery, e.g. by tered with Messe Frankfurt. Fur-
ment department. means of a battery disconnect thermore, approval must also be
switch. obtained from local authorities.
4.4.1.2 Exhibiting motor vehicles - It must be ensured that there is no Pyrotechnic articles lacking a cer-
at stands voltage at the high-voltage battery / tificate of conformity and fireworks
Messe Frankfurt Venue GmbH’s the high-voltage battery must be in of categories II, III and IV are pro-
Technical Project Management a typical, non-critical state for a bat- hibited.
must be notified if motor vehicles tery.
are to be exhibited. This notification - Vehicles with fuel cells or other 4.4.1.5 Balloons
must include the number of vehi- drive units are considered separate- The use of balloons filled with a
cles, as well as the specification of ly. combustible gas in the exhibition
the type(s) of vehicle(s) to be halls or outdoor areas is prohibited.
shown. Demonstrations during the A sufficient quantity of suitable ex- It is possible to apply to Messe
event must be approved by the tinguishing units/agents for all vehi- Frankfurt Venue GmbH’s Technical
Technical Project Management. cles is to be kept available at the Project Management for its per-
Vehicles with combustion engines stand at all times. mission for balloons filled with
- The volume of fuel in the tank Unintentional or negligent move- safety gas that are firmly anchored
should be limited to what is re- ment of the vehicles must be ex- to a stationary structure, are locat-
quired for entering and leaving the cluded by the exhibitor. ed within the stand and do not ex-
premises (the fuel warning light Batteries may only be charged in ceed the maximum height. The dis-
must be active); the fuel cap should the exhibition halls with the prior tribution of gas-filled balloons is
be locked if possible. agreement of Messe Frankfurt Ven- prohibited.
- Vehicles being exhibited may be ue GmbH’s Technical Project Man-
powered by the starter battery as agement. The positions of the vehi- 4.4.1.6 Flying objects
long as it is ensured that no hazard- cles within the stand area must be The use of flying objects such as
ous gases are produced (e.g. by us- shown on a plan. UAS, drones etc. in the exhibition
ing gel batteries and configuring the The relevant rescue sheets must be halls or outdoor areas is only per-

20
Technical Guidelines

4.4 Fire protection and safety regulations

mitted with the prior agreement of ify the times during which the ma- 4.4.1.8 Ash containers, ashtrays
Messe Frankfurt Venue GmbH’s chines will be used and how often If smoking has not been expressly
Technical Project Management. they will be used. Suitable meas- prohibited on stands or parts of
ures must be devised to ensure stands, exhibitors must ensure that
4.4.1.7 Fog machines, hazers, that the volume of fog is kept to a an adequate number of ash con-
Sparkulars, laser systems and minimum in areas where it is not tainers or ashtrays made from non-
other special effects required. It may be necessary for combustible material are provided
Due to the fact that the use of fog, you to obtain the consent of your and that they are emptied regularly.
Sparkulars and haze may trigger neighbouring stands.
automatic fire alarms in the exhibi- Only those fog machines that satis- 4.4.1.9 Containers for trash, re-
tion halls, Messe Frankfurt Venue fy the fundamental requirements of cyclable materials and residual
GmbH’s Technical Project Manage- the German Product Safety Act waste
ment must be notified in writing of [ProdSG] may be used. The type of No containers for trash, recyclable
the use of such devices at least six use and specific conditions of use materials or residual waste that
weeks before the start of the set- must be taken into account when have been fabricated from com-
up period. selecting fog machines. bustible materials shall be set up
This notification must include the The fog machine operator must on stands. All containers on stands
number of such devices, their have access to the corresponding shall be regularly emptied, no later
model(s), and information on the operating instructions. than every evening following the
type of special effect being em- The only fog fluids that can be close of the event, and their con-
ployed. No specific form is neces- used inside the exhibition halls are tents deposited in the containers
sary for this notification. A copy of those which do not contain any for recyclable materials or residual
the operating instructions for the flammable, highly flammable or ex- waste at the stations at exhibition
device(s) must also be provided, as tremely flammable substances pur- hall exits. In the event that large
well as other relevant documenta- suant to Section 3 of the German quantities of combustible waste
tion, e.g. a safety data sheet for Hazardous Substances Ordinance are generated, same shall be safely
fog fluid. The cost of any measures [GefStoffV] and which are not clas- disposed of several times a day.
necessary to deactivate fire alarm sified as hazardous substances un- Trash bags may be deposited in
systems may be charged to the ex- der EU guidelines. Fog machine aisles daily for pick-up following the
hibitor or organiser by Messe fluids can only be stored in the close of the event.
Frankfurt. If the utilisation of fog manufacturer’s original packaging.
machines is not coordinated with During operation it is important to 4.4.1.10 Spray guns, nitrocellu-
Messe Frankfurt and the fire alarm ensure that there is no heat accu- lose lacquers, cleaning agents,
system issues a false alarm as a re- mulation and that the housing is solvents
sult, we will be forced to pass on able to dissipate heat without hin- The use of spray guns is prohibited
the costs resulting from the de- drance. In order to avoid the dan- in all exhibition halls. There is also a
ployment of the fire brigade to the ger of fire from overheating in the ban on the use of all substances,
exhibitor or organiser. event of a malfunction, the power paints, lacquers and varnishes con-
supply to any fog machines not be- taining solvents. The use of flamma-
The use of Sparkulars is considered ing used must be disconnected. ble liquids and construction and
to pose a fire hazard. Messe Frankfurt must be notified if working materials that release toxic
Fog machines or other special ef- laser systems are to be used, and fumes is forbidden.
fects may not be utilised if they re- their operation must be in accord-
sult in the disruption of operations ance with the provisions of Item 4.4.1.11 Work that poses a fire
at neighbouring stands. For this 5.10.3. hazard
reason, it is also necessary to spec- Messe Frankfurt Venue GmbH’s

21
Technical Guidelines

4.4 Fire protection and safety regulations

Technical Project Management 4.4.1.13 Fire extinguishers measures according to Table 1 or 2


must be notified in advance of any Every stand shall be equipped with will be billed to those who caused
work that poses a fire hazard, in- at least one fire extinguisher. See them, including expenses for af-
cluding welding, cutting, soldering, also Section 4.4.1. fected neighbouring stand(s).
separating and grinding. Work can- 4.4.1.14 Water features/pools It is also possible to have multiple
not begin until permission has In the event that water is used in ceiling areas of up to 30 m² within a
been granted and the permit has pools, fountains, water wall and air single exhibition stand, as long as a
been received. The surrounding humidification systems or other minimum distance of 3.00 m is main-
area must be adequately protected spray systems at stands, proper tained between each ceiling area.
against hazards during such work. hygienic conditions must be main- If the contiguous placement of
Suitable extinguishing units/agents tained at all times. Proof of compli- multiple ceiling areas (including
are to be kept in the direct vicinity ance is to be presented to Messe across multiple stands) results in a
and ready to use at all times. Frankfurt on request. total area of greater than 30 m²,
suitable compensatory measures
4.4.1.12 Empty packaging / stor- 4.4.2 Stand ceilings are required (please see Item 4.4.1,
age of materials In order to ensure that sprinkler Table 1 “Fire protection programme
The storage of empty packaging/ protection is not impaired, stands for one-storey exhibition stands
flammable materials of any type in halls with sprinklers must always with closed ground floor ceilings
(e.g. packaging and packaging be open at the top. Ceilings are to and two-storey exhibition stands
materials) either inside or outside be considered open when no more with open top floor ceilings”).
the stand in the exhibition hall is than 50% per each m² of the roofed Closed ceilings are not permitted in
prohibited. All empty packaging is area is covered. foyers. A permit is required for
to be removed without delay. It can Sprinkler-compatible ceilings with closed ceilings larger than 30 m².
be placed into storage by Messe a mesh size of at least 2 x 4 mm or Plans are to be submitted to Messe
Frankfurt’s Logistics Services de- 3 x 3 mm are permissible (no smoke Frankfurt Venue GmbH’s Technical
partment: out). Tarpaulins are to be hung hori- Project Management for its con-
Logistics Services zontally and only in one layer. Tar- sent by no later than six weeks be-
Cargo Center Messe Frankfurt paulins should not be allowed to fore the start of set-up.
Ludwig-Erhard-Anlage 1 sag. Up to 30 m² of contiguous The installation of corresponding
60327 Frankfurt am Main ceiling space may be covered for compensatory facilities (wall hy-
Germany one stand without any additional drant, fire alarm system, visual/
Phone +49 69 75 75-60 75 measures being necessary, as long acoustic alarm, automated smoke
Fax +49 69 75 75-9 60 75 as this does not exceed 50% of the extraction system, sprinkler sys-
logistics@messefrankfurt.com stand area. In order to ensure that tem) is to be performed by compa-
In the event that the exhibitor does multiple ceiling areas taken togeth- nies authorised by Messe Frankfurt
not comply with a request to re- er do not exceed the maximum and entails a fee. Soundproof
move items that are improperly size of 30 m², a distance of at least booths that are 30 m² or larger
stored, or with a request to immedi- 1.50 m from the edge of the stand must be equipped with a fire alarm
ately remove any empty packaging, is to be maintained at all times. system. All soundproof booths – re-
Messe Frankfurt shall be authorised Should a larger ceiling area result gardless of size – must have either
to have the items removed at the from not observing the minimum a visual link with the outside or a
expense and risk of the exhibitor. distance from stand edges, includ- visual signalling system combined
ing across multiple stands, the ex- with an alarm button or emergency-
penses incurred for compensatory off button outside the booth.

22
Technical Guidelines

4.5 Exits, escape routes, doors

All requirements relating to the in- public meeting places], but at the stand. The widths of said exits
stallation of closed ceilings can be least 90 cm) which at no point in and escape routes shall depend
found under Item 4.4.1, Tables 1 and 2. time may be blocked or otherwise upon the maximum number of per-
made unusable. sons and shall be as follows (see
4.4.3 Glass and acrylic glass - If there is no direct line of sight to also Section 4.4.1):
Only glass suitable for the intended the exhibition hall, it is required to – fewer than 200 persons, at
use shall be employed. All glass install an optical and acoustic least 0.90 m;
employed on glass structures shall warning system to ensure that – more than 200 persons, at
be safety glass. You will find further alarms can be triggered at any least 1.20 m.
information on the use of glass and time. This system will be installed Larger exit widths shall be graduat-
acrylic glass in stand construction exclusively by companies under ed in 0.60 m increments per 100
inside the exhibition halls from contract to Messe Frankfurt, at persons only. Escape routes shall
Technical Project Management. the exhibitor’s expense. be marked in accordance with the
The edges of glass panes shall be German accident prevention regu-
ground or protected such that per- 4.5.1 Exits, escape routes lations and ASR A 1.3 “Health and
sonal injuries are precluded. The distance between any point on Safety Signage”.
Structural elements fabricated en- an exhibition area and an exhibition
tirely from glass shall be marked at hall aisle shall not exceed 20 m 4.5.2 Doors
eye level. walking distance. Employment of swinging doors,
Lounges, workrooms, and exhibi- curtains, revolving doors, doors
4.4.4 “Trapped rooms” / tion areas that are intended for that require entry of a code in or-
occupied rooms fewer than 100 visitors, as well as der to open them, sliding doors, or
“Trapped rooms” (rooms which exhibition areas having floor areas other means for restricting access
can only be exited via other occu- of 100 m² or less, shall have at along escape routes is prohibited.
pied rooms) are only permissible least one exit having a minimum Doors in escape and rescue routes
under the following conditions: width of 0.90 m. must open in the direction of es-
- In the rooms through which Every stand with a floor area larger cape; they must not obstruct hall
trapped rooms exit, there must be than 100 m² and/or that is intended aisles when open, must not be
a suitably wide escape route for more than 100 visitors must lockable, and must be easily
(dimensions according to have at least two exits, as far apart opened to their full width from the
H-VStättR [Hessian guidelines on as possible and at opposite ends of inside at all times.

4.6 Platforms, ladders, stairs, landings

Publicly accessible areas that should be designed such that they entails costs for which the exhibi-
directly border on areas more than are difficult to climb over. There tor / stand constructor will be
0.20 m below them shall be bor- must not be more than 0.12 m billed
dered by railings unless they are space between railing/banister The load-bearing capacity of floors
connected to the lower levels by components in any direction. shall, in accordance with its usage,
steps or ramps. The maximum Handrails shall be rigid, provide a conform to DIN EN 1991-1-1/
slope of ramps on rescue and es- secure grip and have no exposed NA:2010-12 Table 6.1 DE (Cat. C1),
cape routes is 6%. The railing must ends. A verifiable structural certifi- and shall be at least 3,0 kN/m². In
be at least 1.10 m high. In areas cation must be submitted for the accordance with DIN EN 1991-1-1/
where small children can be ex- platform; the inspection and ap- NA:2010-12 Table 6.12 DE, railings
pected, railings and banisters proval of this special construction and banisters must be designed to

23
Technical Guidelines

withstand a horizontal live load (for ly-operated turntables are adjacent to – Top floor area between 100 m²
areas of Cat. C1 – C4) of qk = 1.0 other hollow spaces, these are to be and 200 m², more than 200 peo-
kN/m at handrail height. Accessible separated structurally in order to pre- ple: 2 flight of stairs, minimum
single-level platforms cannot be vent the spread of smoke to adjacent width 1.20 m each,
more than 0.20 m above floor level. areas. Ladders, stairs, and landings arranged oppositely
The substructure of the platform must comply with current German ac- – Top floor area more than 200 m²: 2
floor must at least be classified as cident prevention regulations. flight of stairs, minimum width
flame-retardant class B1 in accord- All stairways must comply with DIN 1.20 m each,
ance with DIN 4102 and/or class C 18065. The distance between any arranged oppositely
s2 d2 in accordance with EN 13501- point in the stand and an – For each additional 100 people:
1. For floor coverings, class C fl s1 is exhibition hall aisle shall not exceed an additional 0.60 m is added to
required. Nothing may be stored 20 m walking distance. The number the clear width of each flight of
beneath platforms or podiums. and clear width of stairs shall depend stairs for each additional 100 peo-
They shall have zero fire load. Hol- on the area of the top floor and the ple
low spaces in platforms whose number of persons on the top floor Spiral and circular staircases are ap-
height is less than 0.20 m do not (see also Section 4.4.1): proved for use as auxiliary stairways.
have to be monitored using auto- – Top floor area up to 100 m², fewer Moving components, such as escala-
matic fire alarms. Hollow spaces in than 200 people: 1 flight of stairs, tors or rotating stages (special con-
platforms with automatically oper- minimum width 0.90 m structions), require the prior consent
ated turntables or with concentra- – Top floor area between 100 m² and of Messe Frankfurt Venue
tions of cable fire loads are, insofar 200 m², fewer than 200 people: 2 GmbH’s Technical Project Manage-
as they are higher than 0.20 m, to flight of stairs, minimum width ment. Stairways that are at least
be monitored using automatic fire 0.90 m each, 1.20 m wide must have handrails on
alarms located within the hollow arranged oppositely both sides. Steps that are wider than
spaces. If platforms with electrical- 2.40 m must have central handrails.

4.7 Stand design

4.7.1 Stand appearance the neighbouring stand, so as not ing of supply ducts, ventilation sys-
Exhibitors are responsible for de- to impair the design of the neigh- tems and uneven floors etc., and to
signing their stands, where typical bouring stand. inform the stand constructor ac-
exhibition criteria applicable to the Insofar as trade fair visitors are cordingly.
event in question shall apply. able to look down onto stand roof- Messe Frankfurt assumes no liability
Stand construction shall be such ing, same shall be incorporated for the accuracy of the dimensions
that their edges bordering on into stand designs (Forum 0, Hall given in hall and stand plans.
aisles shall be as transparent as 3.0, Galleria 0, Hall 5.0 West and Assigned stand areas shall be ob-
practicable. The target should be a East, Hall 6.0 East). served at all times. Even lighting
frontage that is 70% open. fixtures and signs should not be
Lengthy, enclosed stand struc- 4.7.2 Verification of rented allowed to protrude beyond the
tures bordering on aisles are not areas boundaries of stand areas.
permitted and must be interrupted Rented areas shall be marked as
by display cases, niches, displays such by Messe Frankfurt. 4.7.3 Interventions in the
or similar. The rear sides of stands Following stand allocation, each ex- structures and equipment of
adjacent to neighbouring stands hibitor undertakes to inform them- buildings
must be kept smooth and be selves on site of the position and di- Components of exhibition hall
white in colour from a height of mensions of any structures or structures and their technical facili-
2.50 m, or must be positioned at facilities on their stand, particularly ties shall not be damaged, dirtied
least 1.00 m from the border of hall supports, fire alarms, the rout- or otherwise altered by, e.g. drilling

24
Technical Guidelines

4.7 Stand design

into same or driving nails or screws Carpets and other floor coverings more than one cable), it is neces-
into same. Painting, wallpapering, in exhibition areas must be at least sary to submit a load plan with the
or affixing posters or other items is flame-retardant according to class order that shows not only the over-
also prohibited. B1 of DIN 4102 and/or class C fl s1 all load, but also all of the individu-
Components of exhibition halls and of EN 13501-1. al loads and cable loads. A sepa-
their technical facilities shall not be Test certificates stating the classifi- rate structural calculation may be
subjected to static loadings by cations of the building materials needed under certain circumstanc-
stand structures or exhibits. employed shall be kept available at es and must be submitted to
The supporting columns of exhibi- the stand at all times. Messe Frankfurt on request.
tion halls located within stands Messe Frankfurt reserves the right
may be enclosed up to the level of 4.7.5 Suspension points/chain to engage a structural engineer to
the maximum stand height allowed, hoists/installation of trusses/ verify the applied loads and the
provided that they shall not be fasteners structures used and/or to monitor
damaged thereby. Elements may only be suspended loads (including by means of digital
Installations on hall supports, walls from the technical facilities provid- load cells).
and technical facilities must be ed for this purpose. This verification / load monitoring
freely accessible If necessary, All suspensions are subject to ap- incurs costs and will be charged to
appropriate servicing hatches must proval and the necessary work the customer/exhibitor.
be provided. must be carried out in accordance The maximum height restrictions
with the applicable DGUV-17/18 also apply to the truss system and
4.7.4 Exhibition hall floors regulation. This also applies to sus- must be observed accordingly.
Carpets and other floor coverings pensions with pre-rigging and sus- Please also be sure to note Item
shall be laid such that accidents pensions with ground support sys- 5.3.6 “Equipotential bonding
will be prevented, and shall not tems. (stand earthing) for metal construc-
extend beyond stand boundaries. All spring-loaded carabiners are tions” when conducting your plan-
Only PE/PP double-sided tape that prohibited, included when used as ning.
may be removed without leaving a secondary securing apparatus
any (safety) for lights. All ropes, cables 4.7.5.1 Electric chain hoists
residues shall be employed for and chain slings used must also be Electric chain hoists may only be
holding carpets and floor coverings in compliance with DGUV-17/18 used in conjunction with suspen-
in place. and must be dimensioned for the sions for heavy loads. Electric
All materials employed shall be load to be borne. chain hoists may not be used with
completely removed by exhibitors The fitters must be in possession suspensions for light loads (Halfen
without leaving any residues. Any of the relevant certification in ac- cast-in channels). Use of
substances such as oil, grease, cordance with DGUV-17/18, “Spe- such electric motors is subject to
paint, and similar must be removed cialist for load-securing devices”. the requirements for electric chain
from the floor immediately. Suspensions from the hall ceiling hoists in the event technology in-
Exhibition hall floors shall not be may only be handled by Messe dustry (Igvw SQ P2).
painted or have anything glued Frankfurt and companies working Available for download at: http://
onto them. Stand utilities, lines laid under contract to Messe Frankfurt. www.igvw.org/igvwsqp2web.pdf
out on stands, servicing access Order forms must be accompanied The weight of the electric chain
hatches etc., shall not be obstructed. by a floor plan showing the sus- hoists must be taken into consider-
Driving or setting anchorings or pended loads and requested sus- ation on the loading diagram to en-
other mounting hardware into the pension point positions. For com- sure that the load-bearing points
floors is prohibited. plex systems (constructions with are not overloaded.

25
Technical Guidelines

4.7 Stand design

The contractor must ensure that lifted, all manual chain hoists must walls. The areas of such stands
the chain hoists are tested every be manned simultaneously, and shall be delimited by markings on
year. The seal of approval must be the load must be raised as syn- exhibition hall floors.
attached to each motor in such a chronously as possible. It is forbid- In the case of stands open on one
way as to be easily visible. The test den to move loads above people side or two sides, 5 cm shall be
records must accompany the using manual chain hoists. The deducted from the confirmed
motors at all times and must be weight of the manual chain hoists stand widths in order to obtain the
kept ready for inspection at the op- must be accounted for in the load clearances between the inner sur-
erating location. These tests do not plan to ensure that the load-bear- faces of their partition walls.
replace the mandatory inspection ing points are not overloaded. Under no circumstances shall par-
by an official expert every 4 years. tition walls be damaged. Messe
4.7.5.3 Fasteners Frankfurt reserves the right to
4.7.5.2 Manual chain hoists Plastic cable ties must not be used invoice exhibitors for any repairs
It is absolutely essential that the in- to secure components that are that may be required.
tention to use manual chain hoists subjected to static loads. Only ap- In the event that exhibitors or their
be specified when an order is proved fastening means (including stand builders shall notice any
placed! For line loads and distribut- high-strength shackles, screw-lock damage to these plastic-coated
ed loads, no more than four manu- carabiners) may be used as fasten- walls at the commencement of
al chain hoists may be used in a ers and safeties. Attachments that stand construction, the service
single construction/system. Manu- are structurally necessary can only office responsible for the hall shall
al chain hoists may only be used in be made using fasteners approved be informed immediately.
conjunction with cables that are at for this purpose (e.g. plastic cable Light objects may be attached to
least 8 mm thick, and only with ties are prohibited!). stand walls using decoration
suspensions for heavy loads. When hooks, which are available from
using manual chain hoists in Halls 4.7.6 Stand bounding walls hall service offices. These hooks
1.1, 4.0, 4.1, 4.2, 5.0, 5.1, 6.0, 6.1, For Messe Frankfurt’s own trade are to be hung on the top edges of
6.2, 9.0, 9.1, 9.2, 9.3, 10.1, 10.2 and fairs, stand dividing walls with a stand wall systems and are capable
10.3 may only accommodate point height of 2.50 m and 0.12 m sup- of supporting loads of 4 kg or less.
loads up to a maximum of 50 kg porting feet can be ordered free of No more than two such hooks
may be lifted. In Halls 1.2, 2.0 charge (up to 21 days before the shall be hung on any wall element.
(Festhalle), 3.0, 3.1, 8.0, 11.0, 11.1, start of the trade fair) via the Shop The stand wall system employed
12.0, 12.1 and Forum, the maximum for Exhibitor Services. After this has plastic-coated surfaces, into
possible point load that can be date, these walls are only availa- which no nails or screws shall be
raised is 100 kg. Once stand con- ble for a fee. driven, which shall not be painted,
struction and set-up activities have Stands open on one side shall be and onto which nothing shall be
been completed, the load is to be provided with one rear wall and glued. In exceptional cases, Messe
removed from the manual chain two side walls. Stands open on Frankfurt Medien und Service
hoists. The load-bearing hook of two sides shall be provided with GmbH (MFS) shall allow walls to
the chain hoist must be suspended either one rear wall and one right be wallpapered using suitable
perpendicularly above the load’s or left side wall, or two side walls materials, provided that it shall be
centre of gravity. The load chain only. Stands open on three sides reimbursed for the costs of restoring
cannot be used for securing loads. shall be provided with one rear them to their original conditions by
A chain bag that has been ap- wall only. exhibitors prior to the commence-
proved for use with the chain hoist Stands open on all four sides shall ment of the wallpapering work
must be present. When loads are not be provided with any partition involved. Affixing lacquered wall-

26
Technical Guidelines

paper, washable wallpaper or any Messe Frankfurt shall be entitled to of stands to be erected on outdoor
other wallpaper having a barrier take action against offenders and, exhibition areas, exhibitors shall sub-
coating of any kind to stand wall if necessary, demand that the mit scale floor plans and top/side/
systems is prohibited. Affixing any offending equipment be shut down. perspective view drawings covering
self-adhesive tapes, foils, or similar For shows and similar events, the the planned stand structures and
to stand wall systems is also pro- Employers’ Liability Association stand design, complete with their
hibited. Additional partitioning regulations “Event and production precise dimensions, to Messe Frank-
walls for conference cabins on locations for stage presentations” furt Venue GmbH, Technical Event
stands or for other subdivisions of DGUV-17/18 must be observed. Management, for approval no later
stands shall be set up at exhibitors’ Messe Frankfurt is to be notified of than six weeks prior to the start of
expense upon request. MFS shall any shows, or product presenta- set-up work. Exhibitors shall be
have the work required performed tions involving shows, that are charged for approvals of stands to be
by a specialist company. planned. erected on outdoor exhibition areas.
Fairconstruction also offers exhibi- Distribution of printed matter and Checked, or checkable, static com-
tors system stands for rental in a employment of advertising media putations shall be included with the
range of standard sizes, equipment by exhibitors is allowed on their sets of drawings submitted. If no
and furnishing packages ranging own stands only. checked static computations are sub-
from 9 to 150 m², as well as custom mitted, checking by a firm of engi-
stands for other stand sizes on re- 4.7.8 Barrier-free construction neering consultants engaged by
quest. These stands can be ordered Stands should be designed to en- Messe Frankfurt shall be required.
using the Fairconstruction stand sure barrier-free access. It should The charges therefor shall be separate-
configurator be possible for mobility-impaired ly invoiced to exhibitors by the respec-
(www.fairconstruction.com). persons to easily access stands tive firm of engineering consultants.
and use their facilities without Insofar as superstructures have been
4.7.7 Advertising media/ assistance. classified as temporary structures, a
presentations valid certification book must be sub-
Stand and exhibit lettering and 4.7.9 Foundations, pits mitted. Messe Frankfurt’s Technical
company and brand logos shall not In the event that exhibitors are plan- Event Managementmust be notified if
exceed the maximum construction ning any foundations, pits or other temporary structures are to be erect-
height (cf. the addendum hereto). structural alterations, scaled plans de- ed. The approval documentation/certi-
Advertising materials, logos etc. tailing the loads and dimensions of ex- fication book must be at the stand for
are to be kept at least 1.00 m from hibits and storage areas must be sub- approval before the start of the event.
the border of the neighbouring mitted to Messe Frankfurt Venue The exhibitor/stand constructor will
stand. Same should have an attrac- GmbH’s Technical Project Manage- be invoiced for the costs of approv-
tive appearance. ment for its consent by no later than ing the temporary structure. In the
Presentations, visual advertising six weeks before the start of the event. event that exhibitors plan any
media, slow-moving and acoustic Exhibitors shall be responsible for all excavations for foundations, pits,
advertising media, and playback of associated costs as well as expenses pipelines, cables, flagpoles etc. in
recorded music shall be allowed, to restore any items altered to their outdoor exhibition areas, approvals
provided that neighbours shall not original conditions immediately fol- for same must be obtained from
be disturbed thereby, no traffic lowing conclusion of the event. Or- Messe Frankfurt, Technical Event
jams shall occur in aisles, and ders are to be directed Management, in good time. This
Messe Frankfurt’s own public ad- exclusively to Messe Frankfurt. work may not be carried out until ap-
dress system shall not be drowned The foregoing general regulations proval has been obtained.
out. Sound pressure levels at the governing stand construction also Ground anchors such as ground
boundaries of the stands involved apply, suitably modified, to stand pegs etc. are not permitted.
shall not exceed 70 dB(A). In the construction and stands erected on
event of violations of that regulation, outdoor exhibition areas. In the case

27
Technical Guidelines

4.8 Outdoor areas

Outdoor areas at Messe Frankfurt structures have been classified as • Torrential rain > 20 l/m² in an
are paved or asphalted circulation temporary structures, a valid certi- hour
areas. fication book must be kept at the • Snowfall up to 10 cm within the
During hours of darkness, outdoor stand. Messe Frankfurt Venue Gm- next 6 hours
areas are illuminated by a general bH’s Technical Project Manage- • Icy surfaces / black ice resulting
network of street and pavement ment must be notified if temporary from the rapid freezing of rain,
lighting in accordance with the structures are to be erected. The drizzle or other moisture Messe
opening hours of the event. approval documentation / certifica- Frankfurt will issue a general se-
The required utility connections are tion book must be at the stand for vere weather warning to all ex-
present at irregular intervals. approval before the start of the hibitors / customers with stand
The foregoing general provisions event. The exhibitor / stand con- constructions in outdoor areas.
for stand construction shall apply structor will be invoiced for the Once this has occurred, all exhibi-
analogously for stands in outdoor costs of inspecting the temporary tors with stand constructions and/
areas. structure. or temporary structures that are
vulnerable to wind load must im-
4.8.1 Stand construction per- 4.8.2 Ground anchors / excava- mediately take all measures neces-
mits / stand structures requiring tions sary to shut down operations. The
consent Ground anchors such as ground necessary measures must be car-
For stands or any constructions in pegs etc. are not permitted. In the ried out in accordance with the
outdoor areas, dimensioned floor event that exhibitors are planning model approval and/or the struc-
plans and perspective views for the any excavations for foundations, tural engineer’s specifications / in-
planned constructions and the de- pits, pipelines, cables, flagpoles spection report.
sign of the stand or construction, etc. in outdoor areas, consent for For mobile items/equipment (e.g.
including the precise dimensions, same must be obtained from small exhibits, furniture, sun um-
must be submitted to Messe Messe Frankfurt Venue GmbH’s brellas, small promotional signs/
Frankfurt Venue GmbH’s Technical Technical Project Management in displays etc.), the exhibitor must
Project Management for its con- good time beforehand. This work ensure that these items can be re-
sent by no later than six weeks be- may only be carried out by compa- moved and stored quickly at any
fore the start of set-up. The inspec- nies commissioned by Messe time in the event of a severe
tion of stands or constructions in Frankfurt Venue. weather warning. Suitable storage
outdoor areas is subject to a fee. In capabilities must be maintained at
the event that structural calcula- 4.8.3 Weather-related loads the stand.
tions examined by a second, inde- 4.8.3.1 Wind loads
pendent structural engineer are not All stand constructions in outdoor Person responsible
submitted, Messe Frankfurt will areas must be adequate in design In order to ensure that everyone
commission a firm of engineering and size to withstand the strains re- can be informed directly of severe
consultants to check the plans and sulting from wind loads in accord- weather warnings, an individual
separately invoice the exhibitor for ance with DIN EN 1991-1-4 and must be designated as the person
their services. The structural engi- the location-specific wind zone. responsible for this for every phase
neer will contact the stand con- of the event (set-up/event/disman-
struction manager at a specified 4.8.4 Severe weather warnings tling) by no later than the start of
time / after consultation to provide In the event that severe weather is the set-up period. The name and
assistance and examine structural expected and any of the following mobile phone number of this per-
characteristics, and to inspect the are forecast: son must be provided, and they
structure for a fee. Due to the addi- • Wind gusts > 13 m/s (wind must remain in the stand/event
tional work entailed, the absence speed > 6 Beaufort scale – in- area in order to be able to immedi-
of structural calculations results in cluding for individual gusts) ately carry out the necessary meas-
additional costs for the exhibitor / • Severe thunderstorms with wind ures for shutting down operations.
stand constructor. Insofar as super- gusts, torrential rain or hail

28
Technical Guidelines

4.9 Two-storey structures

4.9.1 Requests for approval Frankfurt Venue GmbH’s Technical or higher) is required for unre-
Two-storey structures require the Project Management. stricted use as a freely accessi-
consent of Messe Frankfurt Venue Messe Frankfurt will arrange for ble area for exhibitions and as-
GmbH’s Technical Project Manage- the necessary installations and in- semblies, either with or
ment. Requests must be submitted voice the exhibitor for the costs without densely arranged seat-
by no later than six weeks before entailed. ing: qk = 5.0 kN/m2.
the start of set-up to: Structural calculations submitted The intended use must be clearly
Messe Frankfurt Venue GmbH to Messe Frankfurt for inspection evident in the plans submitted for
Technical Project Management or which have already been in- consent. The evidence of stand
Ludwig-Erhard-Anlage 1 spected will be given to a firm of safety must allow for the fact that
60327 Frankfurt am Main engineering consultants commis- anchorings are not permitted.
Germany sioned by Messe Frankfurt to de- A horizontal load amounting to
Email: termine if they are in compliance H = qk/20 (qk = perpendicular live
standapproval@messefrankfurt.com with the construction plans sub- load) at upper floor level must be
Exhibitors shall be charged for mitted. In the event that structural assumed for a two-storey exhibi-
checking of plans for two-storey calculations examined by a sec- tion stand or grandstand in order
structures. Said charges are exclu- ond, independent structural engi- to achieve adequate longitudinal
sive of charges for a required fire neer are not submitted, the engi- and transverse stability.
alarm system or other fire protec- neering consultants will inspect the In accordance with DIN EN 1991-1-
tion measures that may become plans themselves and separately 1/ NA:2010-12 Table 6.12DE, railings
necessary. invoice the exhibitor for their and banisters must be designed to
services. The structural engineer withstand a horizontal live load (for
4.9.2 Restrictions applying to will contact the stand construction areas of Cat. C1 – C4) of qk = 1.0
stand superstructures, safety manager at a specified time/after kN/m at handrail height.
clearances and the heights of consultation in order to inspect the
stand interiors structural characteristics of the Evidence showing that the permit-
In the interest of the overall char- stand. ted loads on the hall floor have not
acter of the exhibition hall and for been exceeded, e.g. by individual
safety reasons, Messe Frankfurt 4.9.3 Live loads/design loads supports (also refer to “Technical
reserves the right to withhold The following working load re- Data on the Exhibition Halls of
approval of two-storey structures quirements apply to the upper floor Messe Frankfurt”) must be provided.
at its own discretion. of a two-storey stand in an exhibi- For multi-storey structures and
The clear height of interiors in tion hall, as perpendicular live special constructions, load-distrib-
multi-storey structures must be at loads in accordance with DIN EN uting base plates measuring at
least 2.30 m. If 30 m² or more of 1991-1-1/NA:2010-12 Table 6.1DE: least 0.20 m x 0.20 m are to be
the stand area is covered by the - The following live load (Cat. C1) provided beneath the supports;
upper storey, this area must be is required for limited use by with high loads these must comply
equipped with an automatic fire trade visitors or by stand per- with the corresponding structural
alarm system. Other measures sonnel engaged in discussions engineering requirements.
may also be necessary – please or assisting customers, i.e. fur- Stairs and landings must always be
see Item 4.4.1, Tables 1 and 2, for nished with tables and chairs designed for a live load (Cat. T2) of
detailed information. The exhibitor arranged freely or in separate qk = 5.0 kN/m2.
is to order any necessary compen- meeting rooms: qk = 3.0 kN/m2.
satory measures from Messe - The following live load (Cat. C3

29
Technical Guidelines

4.9 Two-storey structures

4.9.4 Escape routes / stairways as escalators or rotating stages volume of smoke in the event of a
On the top floors of two-storey (special constructions), require the fire.
exhibition stands, the walking dis- prior consent of Messe Frankfurt
tance from any accessible location Venue GmbH’s Technical Project 4.9.6 Top floors
to the nearest exhibition hall aisle Management. Steps that are wider Guards at least 0.05 m high that
via the stairway shall not exceed than 2.40 m must have central will prevent objects from rolling off
20.00 m. handrails. Handrails shall be rigid, top floors shall be installed on the
All stairway structures shall comply provide a secure grip and have no flooring of top floors, in the vicinity
with DIN 18065. The number and exposed ends. of railings, if required.
inner width of stairs shall depend Railings shall comply with Sections
on the area of the top floor and the 4.9.5 Building materials 4.6 and 4.9.3 above.
number of persons on the top floor All stand construction and decora- The second floor must be at least
(cf. Section 4.4.1): tive materials must at least be clas- 2.5 m away from neighbouring
– Top floor areas up to 100 m2 and sified as flame-retardant class B1 in stands, or the side of the top floor
maximum occupancies of less accordance with DIN 4102 and/or adjacent to the neighbouring stand
than 200 persons: class C s2 d2 in accordance with must be closed with a wall at least
1 stair, minimum width 0.90 m. EN 13501-1. Stricter requirements 2 m high.
– Top floor areas from 100-200 m² apply in particular for materials The top storey should always be
and maximum occupancies of that are used for ceiling structures left open to ensure that the effec-
less than 200 persons: or overhead: they must not only be tiveness of the fire extinguishing
2 stairs, minimum width 0.90 m flame-retardant, but also must not systems is not impaired. If the ceil-
each, arranged oppositely drip while burning. This corre- ings of top storeys are closed, the
– Top floor areas from 100-200 m2 sponds to class C s2 d0 in accord- requirements as shown in table 2
and maximum occupancies of ance with EN 13501-1. For floor of 4.4 Fire protection and safety
more than 200 persons: coverings, class C fl s1 is required. regulations shall apply. All of the
2 stairs, minimum width 1.20 m For safety reasons, special require- necessary fire protection measures
each, arranged oppositely ments may be imposed for load- can be found under Item 4.4.1. In
– Top floor areas exceeding bearing structural components in addition to the fire extinguishers al-
200 m2: individual cases. Materials such as ready present on the ground floor,
2 stairs, minimum width 1.20 m rigid polystyrene foam, PVC or sim- at least one approved and suitable
each, arranged oppositely ilar, as well as various acrylic glass fire extinguisher per stairway (in
– For each additional 100 persons: products, that are readily flamma- compliance with DIN 14406 / EN3)
+ 0.60 m inner stair width ble, drip while burning or form tox- is to be located in a clearly visible
Spiral and circular staircases are ic gases shall not be employed. and easily accessible place.
approved for use as auxiliary stair- The materials used must not con-
ways. Moving components, such tribute to the generation of a large

30
Technical Guidelines

4.10 Misuse / Violation and liability

4.10 Misuse / Violation and commissioned fails to comply with


liability these stand construction regula-
tions, the exhibitor shall be liable
Stand structures that have not for all damages arising as a conse-
been granted permission or that quence of the violation of these
fail to comply with these Technical stand construction regulations. In
Guidelines or legal requirements addition, the exhibitor or the stand
may be subject to alteration or re- constructor they have commis-
moval. Should this alteration or re- sioned shall already indemnify
moval not be completed on time, Messe Frankfurt against any and
Messe Frankfurt is entitled to un- all third-party claims that might be
dertake this itself and/or have this asserted against Messe Frankfurt
performed by a third party, at the as a result of the violation of these
expense and risk of the exhibitor. stand construction regulations.
In the event that the exhibitor or
the stand constructor they have

31
Technical Guidelines

5. Operational safety, technical safety provisions, technical regulations and utilities

5.1 General regulations


Exhibitors are responsible at all Frankfurt at said exhibitors’ ex- DGUV Regulation 1 (German Stat-
times for operational safety and pense following the close of the utory Accident Insurance) if there
maintaining compliance with occu- event. is the potential for endangering
pational health and safety and ac- one another. This also applies to
cident prevention regulations on 5.1.2 Coordinating work on the work performed at the stand by
their stands. All set-up and dis- exhibition grounds the trade fair company’s service
mantling work shall comply with Should it be necessary for employ- providers. Furthermore, the meas-
occupational health and safety and ees of multiple companies to work ures that are necessary for im-
industrial regulations. at the stand / in the event area si- proving safety and preventing
multaneously (particularly during health hazards for employees in
5.1.1 Damage the set-up/dismantling phases), the workplace in accordance with
Any and all damage caused by their work shall be coordinated by the currently applicable European
exhibitors or their agents on the the stand construction manager / Union Directive 89/391/EEC must
exhibition grounds or in the assembly supervisor in accord- be observed and put into practice
grounds’ buildings or facilities ance with the Occupational Health during work on the exhibition
shall be remedied by Messe and Safety Act (ArbSchG) and grounds.

5.2 Employment of tools and other equipment

The use of stud guns may be ap- Logistics Service. The employment for transporting goods at ground
proved on a case-by-case basis. of exhibitors‘ own forklifts is prohi- level is permitted.
The employment of woodworking bited for safety reasons. If required, Electric lift trucks may only be used
machinery that lacks sawdust/chip forklifts for loading and unloading for assembly work on the rented
extraction systems is prohibited. are available on a fee basis from stand area; their use for loading or
Cranes, forklifts and other devices the Messe Frankfurt Logistics unloading is prohibited.
for loading/unloading may only be Service.
used by the Messe Frankfurt‘s The utilisation of electric lift trucks

5.3 Electrical installations

5.3.1 Electrical outlets sons it is necessary that all devices 5.3.2 Electrical installations on
Every stand that is supplied with that consume electricity be turned stands
electric power is provided with one off at the end of every event day Electrical installations on stands
or more electrical outlets. This is when leaving the stand. Exception: may be carried out by an approved
done exclusively by contract part- Emergency lighting, all systems hall electrician. Exhibitors should
ners of Messe Frankfurt and is sub- pertaining to safety and security, submit their orders for same direct-
ject to a fee. The electrical supply refrigerators, computers and serv- ly to the hall electrician. Installation
shall be shut off one hour after ers that are required for stand facil- shall be performed by an electrical
events close on their final day for ities and which would require a contractor authorised by Messe
safety reasons. great deal of time/effort were they Frankfurt.
For safety and fire protection rea- to be restarted.

32
Technical Guidelines

5.3 Electrical installations

5.3.3 Installation and operating copper wiring of types NYM, any combustible decorations or
regulations H05VV-F and H05RR-F having a similar.
All electrical systems shall be in- minimum cross-sectional area of
stalled and operated in compliance 1.5 mm2 shall be employed. All 5.3.5 Emergency lighting
with the latest safety regulations of types of wiring shall be employed Stands on which existing general
the VDE German Electrical Engi- exclusively in compliance with the emergency lighting is ineffective
neering Association, in particular regulations of DIN 0281 and 0282 due to their construction shall
VDE 0100, 0100-718, 0128 and IEC of the VDE (German Electrical require their own additional emer-
standard 60364-7-711. Engineering Association). gency lighting, as required by VDE
Exhibitors shall be fully liable for Employment of any type of flat 0100-718, which shall be laid out
any damage to Messe Frankfurt’s conductors is prohibited. such that it will reliably allow find-
exhibition halls, sections of its Employment of bare electrical ing one’s way to the general escape
buildings, or to exhibition stands or wiring or terminals on low-voltage routes.
exhibits of other exhibitors that systems is prohibited.
may occur due to defective or in- Secondary lines shall be protected 5.3.6 Equipotential bonding
correctly installed electrical instal- against short circuiting and over- (stand earthing) for metal con-
lations. loading. structions
The percentages of high-frequency The constructor must ensure that
or low-frequency interference 5.3.4 Safety precautions all metal constructions (e.g. truss-
transmitted to the network shall All electrical appliances, which es) with electrical appliances are
not exceed those stated under VDE give off heat (hot plates, spot- fitted with an additional equipoten-
0160 and VDE 0838 (EN 50 006). lights, transformers etc.) shall be tial bonding (copper, at least 10
For devices and exhibits with fre- mounted on non-inflammable, mm²) (VDE 0100 Part 711).
quency converters, the exhibitor heat-resistant, insulating bases in
shall install suitable universal cur- order to provide extra protection. The transfer point on the hall floor
rent-sensitive residual current-op- Sufficiently large distances, suited (stand earthing) can be ordered
erated protective devices (RCD) of to the quantities of heat generated, from Messe Frankfurt Venue
type B in accordance with DIN from any combustible materials shall GmbH / Infrastructure Services.
VDE 0664.100. be maintained at all times. Lighting
Furthermore, exclusively insulated fixtures shall not be attached to

5.4 Water and drain installations

Every stand that is to be supplied pipes in the case of drain lines. 8.0 and 9.0 and on outdoor exhibi-
with water or a drain will be supplied Water and drain lines shall be routed tion areas. Within stands, lines will
with one or more connections to over exhibition hall floors to the be routed above floor level, along
water/drain lines. Connections to rear or side walls of stands via the stand walls.
exhibition hall water and drain lines shortest routes. In order to be able to provide ex-
shall be via 1/2-inch pipes in the Underfloor/underground routing hibitors with rapid assistance in
case of water lines and 40-mm may be provided on Hall levels 4.0, the event that problems arise,

33
Technical Guidelines

5.4 Water and drain installations


Messe Frankfurt shall operate an of exhibitor-supplied equipment for safety reasons.
emergency stand-by service, whose shall be invoiced to exhibitors. All installations within the stand
location may be obtained from the Both contracting parties accept the must comply with the current Ger-
hall manager’s office, on all days of “Terms and Conditions for the man Drinking Water Ordinance to
the event in question. Connections Connection and Supply of Water ensure that the installation and op-
on stands shall also be installed and Drains” as integral parts of the eration of a water connection does
exclusively by Messe Frankfurt’s contractual agreement binding not exert any long-term permanent
contract plumbers. upon both of them. effects on the quality of the drink-
Charges for additional plumbing Water supplies shall be shut off on ing water.
fixtures, such as rentals of wash the last day of events, usually one
basins, sinks etc., and for installation hour before the trade fair closes,

5.5 Compressed air/gas installations

5.5.1 Compressed air installa- 1,500 l/min. DVGW regulations regarding instal-
tions Compressed air shall be supplied lation of items of equipment shall
Every stand that is to be supplied commencing on the final day of be binding upon exhibitors. Exhaust
with compressed air shall be equip- set-up periods. Thereafter, com- gases from larger items of equip-
ped with one or more connections pressed air shall be supplied on a ment shall be conducted outdoors.
to supply lines. Installation of said daily basis, commencing one hour Installation of connections to supply
connections shall be arranged by prior to the opening of the event lines shall be arranged by Messe
Messe Frankfurt. and terminating thirty minutes Frankfurt. Access to shut-off valves
Max. pressure: 8 bar (A pressure after it closes. for gas systems installed on stands
reducer should be used, if required.) shall be clearly identified by iden-
Supplied via compressed air hoses 5.5.2 Gas installations tifying markings (safety markings)
equipped with ball valves: Every stand that may be supplied thereon complying with ASR A 1.3
½’’ for flow rates up to 1,500 l/min. with gas/natural gas has one or (“Health and Safety Signage”).
¾’’ for flow rates exceeding more connections to supply lines.

5.6 Machinery, pressure vessels, exhaust systems

5.6.1 Noise generated by exceed 70 dB(A). cable harmonised EU regulations.


machinery Equipment shall be properly operat-
Operation of noisy machinery and 5.6.2 Product safety ed for its intended purposes only
other equipment should be restricted Exhibitors of technical equipment such that users or third parties shall
in the best interests of all exhibitors have to comply with the provisions be protected against hazards to life
and visitors. Noise levels at the of the German Product Safety Act and limb. Under no circumstances
boundaries of stands shall not (ProdSG) and the respective appli- shall machinery or other items of

34
Technical Guidelines

5.6 Machinery, pressure vessels, exhaust systems

equipment be demonstrated with- fairs, exhibitions, demonstrations or 5.6.2.2. Inspection procedures


out the associated safety equip- similar events, provided that the ex- Exhibited items of equipment shall
ment. In the event that items of hibitor clearly points out that the re- be inspected by the responsible
equipment are to be displayed in spective equipment fails to comply regulatory agency, i.e. the Frank-
operation, components thereof or with the provisions of said regula- furt-based Department of Occupa-
items of safety equipment may be tions and may not be purchased un- tional Health and Safety and Envi-
fabricated from transparent materi- til such time as its manufacturer, or ronment of the Darmstadt
als, provided that the same degree its agent domiciled within the EU, Regional Administrative Council
of safety shall be guaranteed. shall provide that it complies there- (Regierungspräsidium), jointly
Exhibited equipment may be sub- with. with the responsible specialist
jected to visual inspection(s) by a Appropriate safety precautions committees of the associated pro-
commission during the event in- must be taken when demonstrating fessional and industrial associa-
volved. In the event that said machinery or equipment. tions, if applicable, and their com-
inspection(s) shall show that the Messe Frankfurt Venue GmbH shall pliance or non-compliance with
equipment involved fails to comply be entitled to prohibit the exhibition applicable accident prevention
with the provisions of the Product or demonstration of equipment at and safety regulations determined.
Safety Act, the Darmstadt Regional any time if, in its opinion, same In order that CE certifications may
Administrative Council (Regierung- might cause safety hazards or dis- be readily verified by the agency,
spräsidium) (Department of Occu- turb others. Irrespective thereof, the EU certificates of conformity
pational Health and Safety and Darmstadt Regional Administrative should be available for inspection
Technical Safety) may, among other Council (Regierungspräsidium) (De- on stands at all times. Exhibitors
measures, assess a fine or prohibit partment of Occupational Health who have any doubts about the
its exhibition, effective immediately, and Safety and Environment) shall equipment to be exhibited should
even if the equipment involved shall be entitled to issue injunctions pro- contact the responsible agency
have already been set up for exhibi- hibiting operation of same. well in advance of the opening of
tion. CE symbols are to be affixed the trade fair involved.
to certain types of machinery and 5.6.2.1 Safety equipment
other equipment as visible evidence Components of machinery and 5.6.2.3 Prohibition of operation
of compliance with the aforemen- apparatus shall be placed in oper- In addition, Messe Frankfurt shall
tioned regulations. In order that it ation only if all of their safety be entitled to prohibit the opera-
may be determined whether appli- equipment is in place and fully tion of machinery, apparatus or
cable regulations have been ob- operational. other items of equipment at any
served in conjunction with their CE Safe, transparent covers may be time if, in its opinion, their opera-
certification, exhibitors shall keep used instead of the normal guards. tion might cause personal injuries
both the associated Germanlan- In the event that items of equip- or property damage.
guage EU certificates of compliance ment shall not be placed in opera-
or manufacturers’ certificates of tion, its safety equipment may be 5.6.2.4 Additional protective
compliance and German-language removed in order to allow visitors measures
operating manuals available on their to inspect the design and work- All work equipment and construc-
stands at all times. manship of its exposed compo- tion machinery must have been
According to Section 3 (5) of the nents. However, said safety equip- tested regularly as specified in the
ProdSG, equipment that fails to ment shall remain visibly displayed German Ordinance on Industrial
comply with applicable EU regula- alongside the machine at all times. Safety and Health. Unsecured
tions may be exhibited at trade loads must not be lifted above per-

35
Technical Guidelines

5.6 Machinery, pressure vessels, exhaust systems

sons. Further information regard- Abt. Arbeitsschutz und Umwelt the Frankfurt-based Department
ing loads above persons at events Gutleutstraße 138 of Occupational Health and Safety
can be found in DGUV Information 60327 Frankfurt am Main and Environment of the Darmstadt
215-313 “Lasten über Personen” Telephone +49 69 2714-0 Regional Administrative Council
(Loads above persons). Further- Fax +49 69 2714-5951 (Regierungspräsidium), which is
more, technical and/or organisa- the responsible regulatory agency.
tional measures must be put in 5.6.3.2 Testing
place to ensure that the failure of a In addition to the submission of 5.6.4 Exhaust gases and
hydraulic system or cable drive certifications of structural and hy- vapours
does not result in the uncontrolled drostatic pressure testing (EC dec- Combustible or toxic gases or va-
lowering of equipment/compo- laration of conformity and required pours or gases regarded as offen-
nents/loads. These measures may documentation in German or Eng- sive by the general public liberated
include blocking access to the dan- lish), on-site approval is also re- or evolved by exhibits or items of
ger area, using hydraulic fuses to quired. In the event that they are equipment shall not be conducted
protect against line breaks, or me- registered by six weeks before the into exhibition halls.
chanical couplings to support the start of the trade fair, pressure ves- Same shall be conducted outdoors
hydraulic cylinder. The exhibitor is sels subject to inspection can be via suitable exhaust ducts, as stip-
responsible for the structural stabil- subjected to an acceptance test at ulated under the currently valid
ity and safe operation of all exhibits the stand by the German Technical version of the German Federal Pol-
and may be required to submit Inspection Association [TÜV] up to lution Protection Act (“Bundesim-
proof of same. Messe Frankfurt re- one day prior to the opening of the missionsschutzgesetz”).
serves the right to engage a quali- trade fair. An individual responsible
fied person to conduct an inspec- for the pressure vessel must be 5.6.5 Exhaust systems
tion at the exhibitor’s expense. present at the stand. Installation of exhaust ducts con-
Inquiries regarding same should be nected to an exhaust outlet for ex-
5.6.3 Pressure vessels addressed to Messe Frankfurt. hausting combustible or toxic gas-
es or vapours or gases regarded as
5.6.3.1 Certificates of approval 5.6.3.3 Rental equipment offensive by the general public
Pressure vessels may only be Since assessments of pressure shall be required. Exhaust ducts
operated at the stand if the testing vessels manufactured in foreign extending outdoors shall be in-
mandated by the current version countries cannot be completed stalled exclusively by Messe Frank-
of the German Ordinance on during the relatively short set-up furt, using its own materials, wher-
Industrial Safety and Health periods, employment of tested ever feasible. Connections to
(BetrSichV) has been carried out. rental vessels is to be preferred. exhibits are to be installed by ex-
The test certificates issued based Exhibitors shall be charged for hibitors. Orders for such exhaust
on said testing shall be kept on rentals of rental containers. systems may be submitted infor-
hand at the exhibition site and mally, but should be accompanied
presented to the responsible regu- 5.6.3.4 Inspections by regulatory by floor plans indicating where
latory agencies for inspection agencies connections should be installed.
upon request. The necessary acceptance certifi- Cost estimates shall be sent to ap-
Information regarding the applica- cates shall be kept on hand for in- plicants. Work shall commence
ble regulations may be obtained spection by regulatory agencies only once they have accepted said
from the during the event involved. Infor- cost estimates and place their or-
Regierungspräsidium Darmstadt mation on same is available from ders.

36
Technical Guidelines

5.7 Employment of compressed gases, liquefied gases and combustible liquids

5.7.1 Compressed gas and to accomplish the purpose of the 5.7.2 Combustible liquids
liquefied gas systems exhibition, a single compressed
The storage or use of compressed gas bottle having a content of 11 kg 5.7.2.1 Operation requirements
gas or liquefied gas in the exhibi- or less may be set up on exhibition Systems that are operated by, or
tion halls or in outdoor areas with- stands. demonstrated using, combustible
out the written consent of Messe Empty gas bottles shall not be kept liquids shall be equipped with non-
Frankfurt is prohibited. or stored on stands or in the exhi- flammable collecting basins on
bition halls. A gas detection sys- their filling fittings, and at other
5.7.1.1 Permission for the use tem is required in some circum- locations where liquids might exit.
of compressed gas bottles stances. The replacement of Any combustible liquids that may
If liquefied gas or other inflamma- cylinders within the exhibition hall enter collecting basins shall be
ble gases in compressed gas bot- must be agreed with Messe Frank- immediately removed and safely
tles are to be used in the presenta- furt Venue GmbH’s Technical Pro- disposed of in order to preclude
tion of exhibits, it is necessary to ject Management. The exhibitor any fire and/or explosion hazards.
obtain the written consent of must check to ensure there are no
Messe Frankfurt Venue GmbH’s leaks before commencing opera- 5.7.2.2 Filling systems with com-
Technical Project Management in tion. bustible liquids
good time beforehand. Due to the fact that filling systems
In accordance with applicable acci- 5.7.1.3 Installation and mainte- with combustible liquids is particu-
dent prevention regulations, com- nance larly hazardous, this may only be
pressed gas bottles shall be pro- When installing or maintaining liq- done when there are no visitors at
tected against impacts, falling over, uefied gas systems, the Technical the event. It must also be ensured
tampering by unauthorised per- Rules for Liquefied Gases [DVFG- that there are no ignition sources
sons and sources of heat. Techni- TRF 2012] (published by the Ger- or electrostatic charges present.
cal Regulations for Hazardous Sub- man Technical and Scientific Asso-
stances 800 [TRGS 800] must be ciation for Gas and Water [DVGW] 5.7.2.3 Empty containers
observed, and designation in ac- and the German Liquid Gas Associ- Empty containers that have con-
cordance with DIN EN 1089 (colour ation [DVFG]) and DGUV Regula- tained combustible liquids shall not
coding) is required. Storage of tion 80 on the Use of Liquid Gas be kept or stored on stands or in
compressed gas cylinders/tanks in must be observed. 5.7.1.1. must be exhibition halls.
the exhibition hall is to be limited observed. The operator of the sys-
to the daily requirement. The stor- tem must compile an explosion 5.7.3 Combustible pastes and
age location must be clearly and protection document pursuant to other fuels
visibly identified by pictograms. Sections 3 and 5 of the Ordinance Heating or cooking devices fired by
on Industrial Safety and Health wood, coal, gas, combustible liq-
5.7.1.2 Employment of liquefied [BetrSichV] and present this with uids or combustible pastes are
gases any application for approval. The prohibited.
Employment of liquefied gases in entire system must be inspected
exhibition halls is generally prohib- by an expert (qualified person) in
ited. However, in the case of ap- accordance with DGUV Guideline
proved exceptions, i.e. if necessary 310-005.

37
Technical Guidelines

5.8 Asbestos and other hazardous materials

Employment or use of building The bases for this injunction are conjunction with the German Reg-
materials that contain asbestos or the German Act on Protection ulation on Prohibited Chemicals
products that contain asbestos or Against Hazardous Substances (ChemVerbotsV), and the Regula-
any other hazardous materials is (ChemG), BGBl I (German Federal tion on Hazardous Substances
prohibited. Law Gazette I), Part I, Page 1703, in (GefStoffV).

5.9 Movie and TV screenings, slide shows and other presentations, stages

Spectator rooms which are larger possible and situated on opposite The provisions of Section 40 of H-
than 100 m² and/or intended for sides of said rooms. VStättR [Hessian guidelines on
more than 100 visitors shall have at Auditoriums accommodating more public meeting places] shall apply
least two exits leading directly to than 200 people require a special for stages/platforms > 50 m².
exhibition hall aisles. Said exits permit (please see Item 4.5).
shall be as widely separated as

5.10 Radiation protection

5.10.1 Radioactive materials and submitted to Messe Frankfurt justified.


Handling or using radioactive ma- no later than six (6) weeks prior to The fire protection authorities of
terials requires approval pursuant the opening of the trade fair in ques- the city of Frankfurt am Main
to the German Radiation Protection tion. (Branddirektion, Vorbeugender
Regulations (StrlSchV); this also In the event that approval has Brandschutz) shall be informed in
applies to exhibiting such materials. already been granted, it shall be writing regarding approved handling
Said approval shall be applied for shown that the planned handling or use of radioactive materials and
in writing with the authorities re- or use of radioactive materials on the installation/usage sites involved.
sponsible for the exhibition site the exhibition grounds is legally

38
Technical Guidelines

5.10 Radiation protection

5.10.2 X-ray systems and Frankfurt Venue GmbH’s Technical and sworn authority before the
sources of broadcast interference Project Management, filled out and start of the event and declared
Operation of X-ray systems or submitted. safe. A copy of the “Inspection
sources of broadcast interference protocol for temporary installa-
requires approval and shall be co- Operators of lasers of Class 3R, 3B tions” is to be submitted to Messe
ordinated with Messe Frankfurt. or 4 must appoint a laser protec- Frankfurt Venue GmbH.
The provisions of the Regulation on tion advisor as this is required by A tour inspection does not take the
Protection Against Injuries Due to the Artificial Optical Radiation Di- place of an inspection on site.
X-Radiation (RöV) shall be observed rective (OstrV).
at all times. The Technical Rules regarding the In the event that the operator mod-
According to §§ 3, 4, 5 and 8, RöV, OSH Ordinance on Artificial Optical ifies or adds to the laser system af-
operation of X-ray systems or Radiation (TROS) shall apply as a ter the inspection by a publicly ap-
sources of broadcast interference measure for protecting against pointed and sworn authority has
requires either approval or notifi- hazards posed by optical radiation. taken place, the permission to op-
cation thereof. The responsible erate the system becomes null and
regulatory agency is the Every laser/device must have a CE void.
Regierungspräsidium Darmstadt, marking; the laser class must be Should this occur (and if no per-
Abt. Arbeitsschutz und Umwelt shown on the device and operating mission had been granted for the
Dezernat IV / F45.2 instructions must be on hand. The laser system), Messe Frankfurt
Gutleutstraße 138 safety instructions contained in the Venue GmbH shall be entitled to
60327 Frankfurt am Main manufacturer’s operating instruc- turn off the power supply to the
Tel. +49 69 2714-1958 or tions must be observed. stand or to confiscate the laser sys-
Tel. +49 69 2714-1961 There must be technical and/or or- tem (the system would be returned
to whom applications for approval ganisational measures in place to on the final day of the trade fair af-
or notifications shall be informally ensure that no one is exposed to ter the event has closed).
submitted in triplicate at least four laser radiation above the maximum
(4) weeks prior to the opening of permissible dose when adjusting 5.10.4 LED
the event involved. or operating the laser system. Frankfurt Venue GmbH’s Technical
The fire protection authorities of When laser systems of Class 3R, Project Management must be no-
the city of Frankfurt am Main 3B or 4 are demonstrated at exhibi- tified if very powerful or very
(Branddirektion, Vorbeugender tions or trade fairs, it must be en- bright LED systems or spotlights
Brandschutz) shall be informed sured that no uncontrolled reflect- of Risk Class 2 or 3 are to be
in writing regarding approved ed radiation can occur, and that used. Suitable extinguishing units/
operation and the installation/usage the laser area around the laser fa- agents are to be kept in the direct
sites of X-ray systems and sources cilities is restricted using barriers or vicinity of all LED systems and
of broadcast interference. covers bearing the laser warning must be ready to use at all times.
symbol so that it is not accessible The rear of LED walls/screens
5.10.3 Laser systems to people. must remain accessible to the fire
The use of lasers or laser systems brigade without the use of tools.
must be registered with and ap- Furthermore, the operation of Class
proved by Messe Frankfurt. 3R, 3B or 4 laser systems is only
The “Registering a laser system” permitted if they have been in-
form is to be obtained from Messe spected by a publicly appointed

39
Technical Guidelines
5.11 High-frequency equipment, radio systems, electromagnetic compatibility and harmonics

The operation of high-frequency the German Telecommunications feasible.


equipment, radio transmitters or Act [TKG] and the Electromagnetic Said approval shall be applied for
other devices emitting electromag- Compatibility of Equipment Act with Messe Frankfurt, stating the
netic radiation requires the approv- [EMVG]. Operation of paging sys- technical data of the systems to be
al of the Federal Network Agency tems, microphone systems, inter- involved. Orders for assignment of
[Bundesnetzagentur] and of Messe communications systems and radio- frequency bands shall be submit-
Frankfurt. The frequency bands communication systems requires ted on the respective order form.
and transmission power must be the approval of the The provisions of the 26th Regula-
specified in order to ensure an Bundesnetzagentur für Elektrizität, tion on the Implementation of the
even distribution of frequencies Gas, Telekommunikation, Post und German Federal Pollution Protection
and to help avoid any mutual inter- Eisenbahnen, Act (“26. Verordnung zur Durch-
ference where possible. Außenstelle Eschborn führung des Bundesimmissionss-
The Technical Project Management Auf der Ludwigshöhe 204 chutzgesetzes”) shall be observed
of Messe Frankfurt shall be in- 64285 Darmstadt whenever exhibits or stand decora-
formed in writing regarding ap- Tel. +49 6151 170-255 tions that employ electric, magnetic
proved operation and the installa- Fax +49 6151 170-181 or electromagnetic fields are exhib-
tion/usage sites of high-frequency Irrespective of any approvals issued ited or employed. Messe Frankfurt
equipment, radio transmitters or by said agency, placing wireless shall be notified regarding any
other devices emitting electromag- paging systems into operation sources of strong magnetic fields
netic radiation. requires the approval of Messe present on stands and their respec-
The operation of high-frequency Frankfurt in order that the frequency tive locations.
equipment or radio transmitters bands involved will be evenly dis-
shall only be approved if it is in tributed and interference will be
compliance with the provisions of precluded to the maximum extents

5.12 Cranes, forklifts, and empty packings

For safety reasons, the operation of German Freight Forwarders (“Allge- forbidden.
exhibitors’ own lifting equipment meine Deutsche Spediteurbedin- Packing materials and exhibitions
on the exhibition grounds is pro- gungen“ (ADSp)) and the Schedule cannot be placed in exhibition hall
hibited. Only the equipment of of Freight Forwarding Rates for aisles – not even briefly.
Messe Frankfurt and its official lo- Trade Fairs and Exhibitions in All empty packing materials are to
gistics partners may be operated. Frankfurt (“Speditionstarif für Mes- be removed without delay.
Forklift and crane services on the sen und Ausstellungen in Frank-
exhibition grounds can only be or- furt”) shall apply to all freight for- They can be stored by Messe
dered from Messe Frankfurt; these warding orders on the exhibition Frankfurt’s Logistics Services de-
services will be performed by its grounds. Transport boxes that are partment:
logistics partners. too heavy to be carried manually,
The same shall also apply for the and whose construction does not Logistics Services
storage of freight/goods and empty allow them to be transported using Cargo Center Messe Frankfurt
packing materials during the event. forklifts or hand pallet trucks, are Ludwig-Erhard-Anlage 1
Customs clearances for temporary not permitted. They may not be 60327 Frankfurt am Main
or permanent imports, on the other brought into the exhibition halls. Phone: +49 69 75 75-60 75
hand, will be provided and in- The storage of empty packing ma- Fax: +49 69 75 75-9 6075
voiced directly by the logistics part- terials or flammable materials of logistics@messefrankfurt.com
ners. The latest version of the Gen- any type in the exhibition hall ei-
eral Terms and Conditions for ther inside or outside the stand is

40
Technical Guidelines

5.13 Musical reproduction

Any kind of musical reproductions messe@gema.de not injured during the event (hear-
shall be subject to provisions of the gema@gema.de ing loss etc.). Generally recognised
German Act for Protection of Copy- www.gema.de engineering standards are set out
right and Related Property Rights in DIN 15905 “Event Technology –
(“Urheberrechtgesetz”), Section 15 Musical reproductions that have Sound Engineering – Part 5: Meas-
of the German Copyright Act not been registered with GEMA ures to prevent the risk of hearing
(“Urhebergesetz”) (German Federal may result in damage claims being loss of the audience by high sound
Law Gazette [BGBl], and shall re- filed by the latter (cf. Section 97 of exposure of electroacoustic sound
quire the approval of GEMA, the the Copyright Act). systems”. The contracting party
musical authors’ rights society, For events featuring musical per- must comply with these standards.
which may be reached at: formances where high sound pres- Furthermore, the contracting party
GEMA Generaldirektion Berlin sure levels (volumes) are expected, must ensure that there is a suffi-
Postal address: the contracting party is responsible cient quantity of hearing protection
Postfach 30 12 40 for determining what, if any, safety devices (e.g. earplugs) on hand
10722 Berlin measures are required to prevent and provide these to visitors on re-
Office address: injury to listeners. The contacting quest unless any danger to visitors
Bayreuther Straße 37 party is responsible for taking through excessive sound pressure
10787 Berlin these measures. The contracting can be excluded. There must be
Telephone +49 30 212 45-00 party must limit the volume such clear notification of this.
Fax +49 30 212 45-950 that visitors and third parties are

5.14 Beverage dispensing systems


The installation and operation of this may in some cases be tested by department at the
beverage dispensing systems is no the Ordnungsamt. EU Regulation Stadt Frankfurt am Main
subject to registration; however, No. 852/2004 of the European Par- Ordnungsamt
the operator of a beverage dis- liament and Council dated 29 April Kleyerstraße 86
pensing system has sole responsi- 2004 on food 60326 Frankfurt am Main
bility for its safety and hygiene. It hygiene shall apply. Tel. +49 69 212 47099
must be possible to demonstrate The monitoring of beverage dis- E-Mail: veterinaerwesen@stadt-
that said systems are free of any pensing systems is performed by frankfurt.de
technical or hygienic concerns, and the veterinary and food safety

5.15 Food inspections


In the event that free samples of Exhibitors should contact the Over-the-counter sales of food or
foods or beverages are to be distri- Stadt Frankfurt am Main beverages at events (including
buted for consumption on site, sta- Ordnungsamt cash sales) is prohibited. Said pro-
tutory regulations must be obser- Kleyerstraße 86 hibition explicitly includes the final
ved, particularly the German Food 60326 Frankfurt am Main days of events.
Hygiene Regulations [LMHV] and Tel. +49 69 212 47099
Regulation (EU) No 1169/2011 on E-Mail: veterinaerwesen@stadt-
the provision of food information to frankfurt.de
consumers [LMIV].

41
Technical Guidelines

5.16 Vehicle and driving demonstrations

Vehicle demonstrations of all kinds Frankfurt Venue GmbH’s Technical


(in exhibition halls and in outdoor Project Management:
areas) require an application and standapproval@messefrankfurt.com.
are subject to consent. For more
information, please contact Messe

42
Technical Guidelines

6. Environmental protection

Messe Frankfurt is fully commit- (e.g. stand constructors) are also related to preservation of species,
ted to protection of the environ- obligated to observe all rules and and shall be held legally and
ment. regulations pertaining to environ- financially responsible for their
As a contracting party of Messe mental protection. Exhibitors shall participation in exhibitions.
Frankfurt, exhibitors must ensure be obliged to comply with all reg-
that their own contracting parties ulations

6.1 Waste

All the following provisions are must be taken into account during Vacating exhibition areas after the
based on the Waste Management the planning stage and end of the event: The exhibitor
Act [KrWG, as amended], the asso- coordinated with all involved. must return the exhibition area in
ciated regulations and ordinances, In general, reusable, environmen- a clean state by no later than the
particularly the Commercial Waste tally friendly materials are to be end of the dismantling period.
Ordinance [GewAbfV], state laws used for stand construction and Adhesive tape, paint residues etc.
and municipal codes. operation. must be completely removed. If a
Exhibitors shall be responsible for The exhibitor and any stand con- request is made with the hall
proper, environmentally friendly struction companies they work inspector’s office, the exhibition
disposal of waste arising during with are responsible for cleaning area will be inspected jointly with
set-up and dismantling of their their stand and disposing of waste the exhibitor’s representative and
stands, as well as during the event. during the event, as well as for its proper return confirmed in
The exhibitor is considered to be disposing of any waste and spe- writing. If the exhibition area is
the party that generated this cial waste that is created during not returned in proper condition,
waste. Collection and transport of set-up and dismantling. These dis- Messe Frankfurt will have it
waste for recycling or disposal posal services may be ordered cleaned and restored at the exhi-
shall be handled solely by Messe from Messe Frankfurt using the bitor’s expense. The exhibitor’s
Frankfurt or its appointed contrac- corresponding form. Messe Frank- liability for accidents and other
tors. furt is to be entrusted with the consequential damages does not
proper disposal of any waste re- end until the area has been prop-
6.1.1 Waste disposal quiring disposal that is created erly cleaned and restored.
In accordance with the Waste during set-up and dismantling. Any materials left behind will be
Management Act (KrWG), the Messe Frankfurt levies an environ- disposed of at increased rates at
Commercial Waste Ordinance (Ge- mental fee to cover the disposal of the exhibitor’s/organiser’s ex-
wAbfV) and the Waste Framework the average usual waste volume pense, without their value being
Directive (Directive 2008/98/EC as generated during the event (excl. assessed.
amended by Directive (EU) set- up and dismantling period).
2018/851), the emphasis should be The exhibitor and/or any stand 6.1.2 Hazardous waste
placed on avoiding the generation construction companies they work Exhibitors and their contracting
of waste at the exhibition grounds with are responsible for sorting parties (e.g. stand constructors)
during the set-up, event and dis- their waste into recyclable materi- shall be obliged to report wastes
mantling phases. This objective als and refuse. such as batteries, lacquers, sol-

43
Technical Guidelines

6.1 Waste

vents, lubricants, paints etc. that Messe Frankfurt dispose of them 6.1.3 Waste brought onto the
are explosive or flammable, or properly. exhibition grounds
whose type, characteristics or Specially designated receptacles Any materials or wastes that are
quantity make them particularly have been set up on the exhibition not produced in conjunction with
hazardous to health, air or water, grounds for smaller quantities of the event or with set-up and dis-
to Messe Frankfurt, and to have these materials. mantling work shall not be brought
onto the exhibition grounds.

6.2 Water, waste water, soil protection

6.2.1 Oil/grease traps employed, exhibitors shall make companies that have been selected
The quantities of oil/grease con- certain that oils and grease shall be to perform the work involved. Exhi-
ducted into the sewer system shall separately trapped and disposed of bitors shall not be entitled to
not exceed the usual household separately. contract cleaning work out to con-
quantities. In the event that quanti- tractors on their own.
ties of waste water containing oil 6.2.2 Stand cleaning/cleaning Cleaning agents containing solvents
and/or grease exceeding same are agents hazardous to health shall be emplo-
to be conducted into the sewer Messe Frankfurt shall assume res- yed only in exceptional cases and in
system, employment of oil/grease ponsibility for cleaning stands at accordance with regulations.
traps shall be required. These must exhibitors’ expense if exhibitors
be in compliance with generally re- have placed orders for same.
cognised engineering standards. If Messe Frankfurt shall contract
mobile catering equipment is to be cleaning operations out to cleaning

6.3 Environmental pollution

Exhibitors shall immediately notify to have the materials involved recy- Exhibitors who would rather not
Messe Frankfurt regarding environ- cled. In the event that packaging handle waste disposal themselves
mental hazards/pollution due to, will be required again for dismant- may order waste disposal services
e.g. petrol, oil, solvents or paints. ling, exhibitors can arrange for its from Messe Frankfurt.
storage by Messe Frankfurt Logis-
6.3.1 Packaging materials tics Services. Exhibitors may have 6.3.3 Manufacturing wastes
The German Packaging Regulation packaging materials that are no Incidences of manufacturing wastes
(“Verpackungsverordnung”) dated longer needed sent off for recycling shall be reported to Messe Frankfurt,
21 August 1998 (German Federal by Messe Frankfurt. stating the types and quantities of
Law Gazette [BGBl] I, p. 2379 inclu- the materials involved.
ding amendments) obliges manu- 6.3.2 Kitchen waste
facturers and sellers to either ac- Kitchen and catering waste shall be 6.3.4 Stand components
cept return of packaging, such as collected and carefully sorted into Exclusively PE or PP adhesive tapes
cartons, foils, crates, pallets etc., or plastics, glass, paper and garbage. shall be employed for laying carpe-

44
Technical Guidelines

6.3 Environmental pollution

ting and cover foils. Waste shall be Orders for disposal of bulk materials
deposited in the waste containers may also be placed with Messe
supplied by Messe Frankfurt during Frankfurt.
set-up and dismantling periods.

45
Technical Guidelines

7. General information

Messe Frankfurt’s House Rules halt work and contact Messe stand construction materials,
apply throughout the entire exhibi- Frankfurt Venue GmbH. Through- empty packaging and exhibits in
tion grounds. out the entire set-up and disman- the aisles is therefore prohibited.
Exhibitors are responsible for tling periods, conditions inside Representatives of the State
operational safety and for compli- and outside the exhibition halls Agency for Occupational Health
ance with occupational safety and and in outdoor areas are similar to and Safety Facilities (“Staatliches
accident prevention regulations on those on a building site, and per- Amt für Arbeitsschutz und Sicher-
their stands, and shall be liable for sonnel must be informed of the heitstechnik”), regulatory authori-
any damages that result from the particular hazards involved. ties, institutions for statutory acci-
construction or operation of their Throughout the setup and disman- dent insurance and prevention,
stands or the exhibits thereon. tling periods, conditions inside police, fire brigades and Messe
The exhibitor and their contracting and outside the exhibition halls Frankfurt are to be granted access
parties must ensure that their set- and in outdoor exhibition areas to the stand at any time in order
up and dismantling activities do are similar to those on a building to inspect operational safety and
not endanger any other persons site. The exhibitor must inform accident prevention measures. In
present in the venue. Insofar as their personnel of the hazards the event that safety hazards are
necessary, the exhibitor and their involved. found, the instructions of the
contracting parties must ensure Hall aisles are rescue routes and aforementioned organisations are
that their activities and work are must be kept clear during set-up to be followed without delay.
properly coordinated. If this is not and dismantling phases, as well
possible, they must temporarily as during the event. Storage of

7.1 Limitation of Liability

Messe Frankfurt assumes no duty In other respects, Messe Frankfurt shall be limited to the typical dam-
of care for exhibited goods or only ever assumes liability in cas- ages that were foreseeable when
stand facilities and, in this re- es of wilful intent or gross negli- the contract was concluded. In
spect, accepts no liability whatev- gence. Messe Frankfurt also ac- this respect, Messe Frankfurt shall
er for damage or loss. This dis- cepts liability for damages caused not accept any liability whatever
claimer of liability is by no means by simple negligence as long as for indirect damage or consequen-
restricted by guarding or surveil- such negligence relates to an in- tial damage caused by a defect,
lance measures implemented by fringement of those contractual particularly including lost profits.
Messe Frankfurt. All cases of duties which are of essential im- The aforementioned disclaimer of
damage must be reported to the portance for fulfilment of the pur- liability does not apply to death,
police, to the insurance company pose of the contract (material con- physical injury or damage to
and to Messe Frankfurt without tractual obligations). health.
delay. ln such cases, claims for damages

46
Construction
heights
of the halls of Messe Frankfurt

Valid from 01.05.2023

47
Construction heights

Inhaltsverzeichnis

Seite 49 General construction height limits – CMF, Forum, Halls 1-6


Seite 50 General construction height limits – 8-12

The specified construction height limits are only applicable for Messe Frankfurt’s own events.
Please note that individual events may have different construction height regulations.

Guest events
The construction height limits in force for guest events must be obtained from the organisers.
All heights must be checked on location.

Messe Frankfurt is not responsible for the accuracy of the information.

48
Construction heights

Construction heights of the exhibition halls 1-6, CMF and Forum

Hall Stand size up to 30 m2 Stand size over 31 m2


CMF Harmonie 4,00 m 4,50 m; by agreement
Forum 0 4,00 m * 6,00 m
Forum 1 4,00 m 6,00 m
1.1 4,00 m 4,00 m
1.2 4,00 m * 6,50 m
2.0 4,00 m * 8,00 m
Gallery 4,00 m 4,00 m
3.0 4,00 m * 8,00 m
Northern bordering area 4,00 m 6,50 m
3.1 4,00 m * 8,00 m
Western bordering area 4,00 m 5,40 m
Southern bordering area 4,00 m 5,00 m
Eastern bordering area 4,00 m 6,00 m
4.0 4,00 m * 7,00 m
Northern / Southern bordering area + Gate´s 4,00 m By agreement
4.1 4,00 m 4,00 m
4.2 4,00 m 4,00 m
5.0 ** 4,00 m * 5,00 m
Hall wall east / west ** 4,00 m 4,00 m
5.1 4,00 m * 8,00 m
6.0 4,00 m * 6,00 m
Niches north / south 3,50 m 4,00 m
Hall pillars 4,00 m By agreement
6.1 3,70 m 3,70 m
Niches north / south 3,50 m 3,50 m
6.2 3,70 m 3,70 m
Niches north / south 3,50 m 3,50 m

* The maximum construction height of 5 meters applies only to suspended components such as rigging, lighting and
advertising media. These must be indented to neighboring stands by at least 1 meter.
** Hall 5.0: All hall columns have a diameter of 80 cm up to 4.83 m. After that, the column spreads conically.
Hall wall east/west: All hall columns have a diameter of 80 cm up to 3.8 m. After that, the column spreads conically.
Two-storey structures cannot be built in Hall 5.
The specified construction height obtained from the organisers. height, it is necessary to ensure
limits are only applicable for Messe All heights must be checked on lo- that the rear sides of walls facing
Frankfurt’s own events (please cation. Messe Frankfurt is not re- neighbouring stands are smooth
note the special construction sponsible for the accuracy of the and generally of a neutral colour
height limits). The construction information. (e.g. white or light grey).
height limits in force for guest There may be structural constraints
events (e.g. Achema, Frank- in certain halls. The basic construc- Technical Project Management
furt Book Fair, CPhI etc.) must be tion height is 2.50 m. Above this Valid from May 2023

49
Construction heights

Construction heights of the exhibition halls 8-12

Hall Stand size up to 30 m² Stand size over 31 m²


8.0 4,00 m * 8,00 m
Western bordering area 3,50 m by agreement
9.0 4,00 m * 7,50 m
9.1 4,00 m 4,00 m
9.2 4,00 m 4,00 m
9.3 4,00 m 4,00 m
Galleria 0 3,40 m 4,00 m; by agreement
Galleria 1 3,50 m 5,00 m
10.0 3,00 m 3,00 m
10.1 3,00 m 3,00 m
Niches north / south 2,50 m 2,50 m
10.2 3,50 m 3,50 m
Niches north / south 3,00 m 3,00 m
10.3 3,50 m 3,50 m
Niches north / south 3,00 m 3,00 m
10.4 3,50 m 3,50 m
Niches north / south 3,00 m 3,00 m
11.0 4,00 m * 8,00 m
11.1 4,00 m * 8,00 m
12.0 4,00 m * 8,00 m
12.1 4,00 m * 8,00 m

* Overall height up to 5 m top edge only for suspended components such as (rigging, lighting, advertising media) to
neighbouring stands around by at least 1 metre.

The specified construction height obtained from the organisers. height, it is necessary to ensure
limits are only applicable for Messe All heights must be checked on lo- that the rear sides of walls facing
Frankfurt’s own events (please cation. Messe Frankfurt is not re- neighbouring stands are smooth
note the special construction sponsible for the accuracy of the and generally of a neutral colour
height limits). The construction information. (e.g. white or light grey).
height limits in force for guest There may be structural constraints
events (e.g. Achema, Frank- in certain halls. The basic construc- Technical Project Management
furt Book Fair, CPhI etc.) must be tion height is 2.50 m. Above this Valid from April 2022

50
Messe Frankfurt GmbH
Ludwig-Erhard-Anlage 1
60327 Frankfurt am Main
Phone +49 69 75 75 - 0
Fax +49 69 75 75 - 64 33
www.messefrankfurt.com

You might also like