003 LGF Roof Plan A0 Unit 6 Rev C
003 LGF Roof Plan A0 Unit 6 Rev C
003 LGF Roof Plan A0 Unit 6 Rev C
GENERAL NOTES
REVISIONS
REV. DATE DESCRIPTION
64 1. ALL LEVELS AND DIMENSIONS TO BE CHECKED ON
SITE BY CONTRACTOR PRIOR TO ANY CONSTRUCTION A 2018/07/24 1. FIRST ISSUE
WORK BEING DONE
2. ALL WORK TO BE IN ACCORDANCE WITH SANS B 2018/11/14 1. ALL RC CORE WALLS REVISED TO 230mm
10400-2010 AND ALL MATERIALS USED TO BE OF SABS RC WALLS
APPROVED STANDARDS
3. ALL STRUCTURAL WORK TO BE TO ENGINEERS DETAIL 2. YARD WALL STRETCHED ACCORDINGLY
AND SPECIFICATION, AND UNDER HIS SUPERVISION 3. EXTERNAL WALL TO BEDROOM 4 &
4. ANT GUARD ABOVE DPC TO NBR REQUIREMENTS ENSUITE, STRETCHED OUT 950mm TO
AS BUILT 75° DRY STACK RETAINING WALL TO ENG WITH SOIL POISONING BELOW SURFACE BED MAINTAIN THE ORIGINAL OVERHANG.
DETAIL UNDER APPROVED PLAN NO. 16/08/532 5. WALLS TO BE REINFORCED WITH BRICK FORCE
6. LIGHTING AND VENTILATION TO COMPLY WITH PART O 4. NEW SLOT WINDOW X01 ADDED TO
OF SANS 10400 SCULLERY
7. ALL DRAINAGE TO BE LAID BY A PROFESSIONAL
REV C PLUMBING CONTRACTOR AND TO COMPLY WITH SANS C 2019/03/05 1. NEW SWIMMING POOL.
2. NEW HARDWOOD TIMBER DECK
A REV C B 10400
8. SEWER AND STORM WATER PIPES UNDER SLABS TO
SURROUNDING SWIMMING POOL.
BE IMBEDDED IN CONCRETE
9. FOUNDATIONS TO BE TAKEN DOWN TO VIRGIN SOIL
10. ROOF DESIGN TO ROOFING SPECIALIST DETAIL.
11. ALL SLIDING AND FOLDING GLASS DOORS TO BE
SAFETY GLASS. ANY GLASS BELOW 800mm TO BE
SAFETY GLASS IN ANY DOORS AND WINDOWS, AS PER
SANS 10400 PART N.
68 12. NGL IN APPROXIMATE POSITION ONLY.
SWIMMING POOL WALLS TO
13. PRE-CAST LINTOLS TO BE PROVIDED OVER ALL
RECEIVE DERBIGUM oea
DOORS AND WINDOWS, UNLESS OTHERWISE SPECIFIED
WATERPROOFING BY SPECIALIST
65 14. ALL GLAZING TO COMPLY WITH PART N OF SANS
10400
15. ALL DISCREPANCIES AND OMMISIONS ARE TO BE
A B BROUGHT TO THE ARCHITECT'S ATTENTION
IMMEDIATELY
16. I.E.'S TO BE PROVIDED AT ALL BENDS AND
JUNCTIONS
17.WASTE AND VENT PIPE TO BE 50mmØ PVC AS
SPECIFIED
18. SOIL PIPES AND VENTS TO BE 110mmØ PVC AS
SPECIFIED
19. ALL TRAPS TO BE "S" AND "P" TYPE AS SPECIFIED
20. R.C. - DENOTES REINFORCED CONCRETE, ALL TO
69 8835 STRUCTURAL ENGINEER'S SPECIFICATION
7495 230 23. DPC TO BE PROVIDED AT WALL AND FLOOR
INTERSECTION
230
230
24. VERTICAL DPC TO BE PROVIDED ON ALL RETAINING
WALLS
25. ALL SEWER LEVELS TO BE VERIFIED ON SITE BY
RETAINING WALLS TO RECEIVE CERTIFIED PLUMBER
DERBIGUM oea WATERPROOFING 230 26. 115mm THICKNESS HAS BEEN ALLOWED FOR
BY SPECIALIST STONEWORK CLADING
BUT THICKNESSES MAY VARY ACCORDING TO PRODUCT
USED
Ø110mm PVC SVP AIR 27. ALL ALUMINIUM DOOR AND WINDOW FRAMES TO BE
VENT COWL VENTING EPOXY POWDER COATED: MATT CHARCOAL BY
THROUGH ROOF APPROVED MANUFACTURER - SAMPLE TO BE APPROVED
66 BY ARCHITECT
FBO OVP
M.H. S12 67
CL - 66.30
9805
9575
IL - 64.80
DEPTH - 1 500mm
8345
RE6
Ø110mm PVC SVP AIR
VENT COWL VENTING
66 THROUGH ROOF
FBO OVP
IE RE5
68
230
230
230
230
230
730
270
RWDP SP FROM
GF ABOVE FBO
FBO
HARDWOOD TIMBER
RWDP FROM
1200
HANDRAIL TO
BRICKWORK GF ABOVE
COMPLY WITH SANS
WITH RULED
10400 PART M 4.3.1
10
8
23340
STAIR 01
18 RISERS @ 175mm
16 TREADS @ 300mm
300
11 FILL
7 R.C. ROOF SLAB AND BEAMS TO ENG
3330
300
5330
5
CRUSHED STONE
5560
5100
5100
5560
300
14 SURFACE BY SPECIALIST
4
CRUSHED STONE
ON SCREED LAID TO FALL
300
15
3 TO FULL BORE OUTLETS
300
16 CRUSHED STONE
2 Ø110mm PVC SVP OVP
300
TILES
C A
01
FFL 66.955 5745
5515 230
C C C
230
230
230
GMS COLUMN S RETAINING WALLS TO
TO ENG DETAIL 01 SELF CLOSING CLASS 'E' FIRE 230 1200 3140 330
RECEIVE DERBIGUM
998
12815
12815
12355
1430 RATED DOOR TO COMPLY 1430 3370
oea WATERPROOFING
WITH PART T SABS 10400
BY SPECIALIST
13305
BRICKWORK WITH
FINISH
RULED PLASTER
FBO
3445
RETAINING WALLS
TO RECEIVE
FIRE WALL TO EXTEND TO DERBIGUM oea LAWN
UNDERSIDE OF SLAB AND HAVE A WATERPROOFING BELOW
MINIMUM FIRE RATING OF 30min AS BY SPECIALIST
PER PART T SANS 10400
3470
SW CUT-OFF DRAIN
3140 330
67 E E
330
230
4800
6795
7255
GARAGE
7025
SWS GRANO
FBO
FFL 66.855
7975
BRICKWORK WITH
T
RULED PLASTER
U
D D D D
YO
LA O
DRIVEWAY
ES T
C P
PAVERS
VI W
FINISH
EE m
5120
5780
SP FROM TO FULL BORE OUTLETS SURFACE BY SPECIALIST
SW
230
230
Ø110mm PVC SVP
230 230 AIR VENT COWL
720
230
S.W.M.H W02
CL - 67.50 PROJECT : PROPOSED NEW DWELLING
IL - 66.10 RE3
2670
330
900
OCCUPANCY : H3
4570 230
DRAWING TITLE : CONSTRUCTION DRAWINGS
5600
230
230
AUTHOR'S SIGNATURE
SCALE : 1:50
DESIGNED BY : DL
DRAWN BY : SF
A B A B
DRAWING NO. : 2016/03/29/003 REV: C
LOWER GROUND FLOOR PLAN ROOF PLAN
SCALE 1:50 SCALE 1:50
69 metropole architects