Loads:
Load Factor for Vertical Loads= 1.0
Load Factor for Lateral Loads= 1.0
Loads Supported by Pile Cap= 0 %
Shear Condition: Static
Profile:
Pile Length, L= 30.0 -m
Top Height, H= 0 -m
Slope Angle, As= 0
Batter Angle, Ab= 0
Vertical capacity:
Weight above Ground= 0.00 Total Weight= 101.79-kN *Soil Weight is not included
Side Resistance (Down)= 1354.945-kN Side Resistance (Up)= 1354.943-kN
Tip Resistance (Down)= 24.389-kN Tip Resistance (Up)= 0.000-kN
Total Ultimate Capacity (Down)= 1379.334-kN Total Ultimate Capacity (Up)= 1456.732-kN
Total Allowable Capacity (Down)= 1367.140-kN Total Allowable Capacity (Up)= 779.261-kN
OK! Qallow > Q
Settlement Calculation:
At Q= 10.00-kN Settlement= 0.00161-cm
At Xallow= 2.00-cm Qallow= 952.64331-kN
Note: If program can't find result or the result exceeds the up limits. The result shows 9999.
Software
CivilTech Ali