Professional Documents
Culture Documents
Optima UVIS-100 Flush Mount Under Vehicle Inspection System
Optima UVIS-100 Flush Mount Under Vehicle Inspection System
tc
USER MANUAL
&
INSTALLATION INSTRUCTIONS
1 www.optima.tc
ISO 9001: 2015
SYSTEM SPECIFICATIONS
AND
DATASHEET
2 www.optima.tc
ISO 9001: 2015
1. GENERAL INFORMATION
OPTIMA UVIS-100 systems are designed with advanced security technology to scan and
inspect underside of all types of vehicles. These systems are used especially for entrances where
there is a threat of suicide vehicle attack with explosives or for the entrances that have very high
security requirements like army, industrial, governmental and commercial buildings, sites, complexes
etc.
UVIS-100 under vehicle inspection system provides users needed safe area, thereby
capturing and monitoring underside image of the vehicles with a high-resolution auto digital area
scanning camera. In addition, the system specifies suspicious objects after scan process and takes
them on the monitoring screen. The system is able to handle vehicle moving at speed from 0-50
km/hr and can perform bidirectional scanning from both directions.
Thanks to system’s advanced electronics, many types of security systems such as road
bollards, road blockers, barriers etc. or plate recognition systems can be integrated to OPTİMA UVIS-
100. Optima Plate Recognition Systems read and store vehicle plates “with” undercarriage image of
UVIS system which provides retrieve and search to compare with previous images.
User interface of the software is very friendly and useful for operators. Web interface allows
to monitor recorded informations from anywhere in the world.
3 www.optima.tc
ISO 9001: 2015
1.1. STANDARD EQUIPMENTS IN UNDER VEHICLE INSPECTION SYSTEM
Basic Product UVIS-100 Scan and investigate under side of the vehicle.
ALPR 100+Vehicle Brand,Color & Compare license plate with the color, type & brand of the
Option 2
Type Recognition vehicle with previous images.
4 www.optima.tc
ISO 9001: 2015
Option 8 Red/Green Traffic Light
Between -20 °C and +60 °C (-4°F and 140°F), % 95 or less non-condensing humidity.
2. SYSTEM COMPONENTS
5 www.optima.tc
ISO 9001: 2015
Maximum Diameter (ratio): F=1:2.8 ~16
Distortion: -0.5%
Minimum Focus Distance: 0.10m
Temperature Range: -10 ~ +45°C
6 www.optima.tc
ISO 9001: 2015
Fig.2. Side View of Web Interface Operator Console
7 www.optima.tc
ISO 9001: 2015
OPERATING INSTRUCTIONS
OF
UVIS-100
8 www.optima.tc
ISO 9001: 2015
3. OPERATING INSTRUCTIONS
3.1. LOGIN
An user name and password is required to login system. After system installation is
completed, an administrator account is given to authorized person by OPTİMA. This person is able to
manage and create new accounts for other users.
IP address of the unit should be typed inside web browser’s address bar to access Login Page
and pressed “Enter”.
After pressing “Enter”, the user redirects to Login Page. As long as user name and password
are correctly in this page, reporting and management system will be accessible.
9 www.optima.tc
ISO 9001: 2015
3.2. RECORDS
Plate Recognition Records, Average Speed Records, Parking Violation Record, Transition
Away Records, Return Ban Violation Records, Overspeed Violation Detection System, Red Light
Violation Records, Radar (Speed) Violation Detection Systems, General Violation Records, Records
Held, Unreadable Plate Records, Plate Records (Live) (Table), Plate Records (Live) (Visual) are
accessed by Records tab at the left side on the main page.
If user would like to refresh the records automatically, “Registration automatically renew”
should be marked.
Number of records shown on the page can be changed with the help of below box.
10 www.optima.tc
ISO 9001: 2015
3.2.1. Plate Recognition Records
This tab shows all plates that the system reads. There are various information related to
recognized plates.
There are “Edit”, “List” and “Delete” buttons at the end of the table. With the help of “Edit”
button, plate and country information can be updated. When an update is made, this interference
will be recorded by the system.
11 www.optima.tc
ISO 9001: 2015
When “Edit” button is clicked, page as shown below picture will appear. Various changes can
be made here. Changed records are indicated with an exclamation mark next to the plate column.
Records can be added to the “White List” or “Black List” by using “List” button. Details of this
subject have been explained in the “List” category.
12 www.optima.tc
ISO 9001: 2015
3.3. LIVE TRACKING
It is used to monitor the cameras integrated to the system. The cameras are classified
according to their regions. When the desired camera is clicked, live image can be monitored in the
opened window. Cameras can be added from “System Settings” tab.
When “Video Wall” is clicked, real time images of vehicle are displayed on monitor. In the
database, the images of the vehicle that is recognized as the last plate are observed.
13 www.optima.tc
ISO 9001: 2015
3.5. UNDER VEHICLE INSPECTION SYSTEM
In this section the user can apply Threshold, Grayscale, Brightness, Blur, Sharpen and Sobel
filters to under vehicle, license plate and driver images. In this way, the details of images can be
observed more clearly. The user can zoom comfortably on the image.
Threshold: Used to remove noise in the image. The purpose of the threshold operation is to
seperate the objects in the image from the image background.
14 www.optima.tc
ISO 9001: 2015
Grayscale: In the gray image, the average value of each pixel value is taken. Only gray tones
of image are monitored.
15 www.optima.tc
ISO 9001: 2015
Blur: Image clarity and blur are observed with this filter.
16 www.optima.tc
ISO 9001: 2015
Sobel: The filter provides edge detection for color images. The image is divided into three
color components in RGB space.
3.6. LIST
Desired plates can be added to “Black List” or “White List” from this tab.
17 www.optima.tc
ISO 9001: 2015
3.6.1. White List
Barrier, road blocker which is integrated to the system will be opened by plate recognition
system when the plate added to white list is matched with recognized plate.
New vehicles can be added to the White List from “Add New” section located to right upper
side on the list.
After the required information is entered, vehicle is added to the list by clicking the "Save"
button.
18 www.optima.tc
ISO 9001: 2015
3.6.2. Black List
Barrier which is integrated to the system will not be opened by plate recognition system
when the plate added to black list is matched with recognized plate and the system will give a
warning.
This tab is used to add new users, delete or edit existed users and create user groups.
Used to create a new user. A password and user name are created for new user. User name,
password, registration number of user, region, groups and permission type are specified and new
user is created.
19 www.optima.tc
ISO 9001: 2015
3.7.2. Edit or Delete User
Any user in the user table can be deleted or any information of the user can be edited with
the “Edit” button.
This section is used to authorize users collectively. A new user group can be created and
various authorities can be given to this group.
The system keeps user actions. These actions are stored in the “Transaction Logs” tab and
are monitored.
20 www.optima.tc
ISO 9001: 2015
This table includes processing type, user information, content, time and processing IP.
Thanks to this tab, required adjustments are made. During first setup, components are
defined to the system respectively as below;
21 www.optima.tc
ISO 9001: 2015
INSTALLATION OF
UNDER VEHICLE INSPECTION SYSTEM
22 www.optima.tc
ISO 9001: 2015
4. INSTALLATION OF UNDER VEHICLE INSPECTION SYSTEM
1) Study carefully AutoCAD layout drawings for civil and electrical works supplied by Optima
before installation.
2) Make a visit to the site and analyze how to locate the system by measuring distances.
3) Chalk or lime the area to determine the area to be excavated by following AutoCAD drawings
provided by Optima.
4) Break the asphalt or concrete coating with help of hydraulic hammer.
5) Dig a pit as shown in Fig.4.
23 www.optima.tc
ISO 9001: 2015
6) Place the sheet metal provided by OPTIMA in place.
7) After placing drainage pipe and electricity/data pipe, pour concrete around sheet metal pit.
24 www.optima.tc
ISO 9001: 2015
8) After completing the civil works, place the image receiver unit using eye-bolts.
25 www.optima.tc
ISO 9001: 2015
4.2. INSTALLATION PROCEDURES OF LOOP DETECTOR ANTENNAS (IF REQUIRED)
Important Note
For an effective performance, the antenna cables must not vibrate during usage. Therefore,
the procedures listed above must be followed precisely.
26 www.optima.tc
ISO 9001: 2015
UVIS-100 OPERATION
AND
MAINTENANCE
27 www.optima.tc
ISO 9001: 2015
5. MAINTENANCE
Environmental conditions like dust, humidity affect working and expected life of the system
negatively. So, cabinet and equipment which is exposed to dust, can be cleaned with pressure air for
removing dust. Users should avoid from any damages on the mechanical and electronical parts
during cleaning.
Before the cleaning, make sure to disconnect the system from the source of electricity.
In the UVIS systems, deformations on the cables at the time of installation can cause short cable
life. In situations like this, conducting wires can cause short circuit or can break in time.
In the maintenance time, connection points of cables should be controlled to prevent loose
connection in every six month.
Connection points of hinges should be checked. In case of necessity, fix loose connection.
Otherwise, view point of the camera can be changed and If these is any break on the material, it
should be replaced with new one. Check camera stand in every month.
Plate recognition camera should recognize and transfer plate information to the computer
display correctly. Check its performance and functionality daily.
Check scanning image when the vehicle drive through from scanner. Check its performance and
functionality daily.
Housing should be cleaned from outside with a damp cloth in every two weeks. Please, be careful
during cleaning; don’t change viewing point of the camera.
IR LEDs provide required lights to IR camera for recording in the dark. So, user should check
functionality of IR led lights daily.
28 www.optima.tc
ISO 9001: 2015
Under Vehicle Inspection System Light Source Check
LED light source should activate automatically during passage of vehicles. After underside of the
vehicle is scanned, it should be deactivated. Check functionality of LED light source daily.
Check the hard disk functionality of computer system daily. Make sure that information which
have been stored and reported can be accessible.
Check PCB board daily. If PCB board is working normally, green led indicator should be active.
There is a LCD screen on it. This display should show temperature rating. Check this sensor
functionality daily.
Images should be transferred clearly in daytime and nights. So, check image quality and
resolution which is transferred to computer system daily.
If there is any damaged components or exposed to corrosion, replace it with the new one. The
relevant parameters should be adjusted by engineer before usage.
Click control software, log into normally. Inspect the software functionality daily.
Power off the system once in every two weeks for 30 min.
Electrical Control
In order to ensure good electrical performance, ensure that electrical voltage in the 220-240 VAC
range.
29 www.optima.tc
ISO 9001: 2015
REPLACEMENT
PC Machine Replacement
Step 1: Power off the system and pull-out the power plugs.
Step 4: Disconnect the cables and remove the main machine box from the operator console.
Monitor Replacement
Step 3: Remove the LED wire on the main control board, power line, ground sense control line,
camera power, signal line, temperature & humidity control line.
30 www.optima.tc
ISO 9001: 2015
Scanner LED Replacement
31 www.optima.tc
ISO 9001: 2015
32 www.optima.tc
ISO 9001: 2015
33 www.optima.tc