SPESIFIKA SI PATIENT MONITOR : DRAEGER - VISTA 120S

Type Parameter Merk FEATURES : Vista 120S Advance (Invasive & EtCO2)
: ECG, SpO2, RR, NBP, Temp, IBP, etCO, C.O
: Draeger
: Bedside monitor for ER, HCU, ICU, OR, RR advanced measurements
: Scalable: offers a choice of three models to meet diverse clinical needs patient data
: Easy to use: provides quick access menu, hard keys, and a rotary knob
: Built-in recorder: saves time by providing documentation when needed
: Networking: functions as a standalone or networked monitor

TECHNICAL DATA
Display Specifications
Display screen : 12.” color TFT
Resolution: : 800 × 600
Waveforms : Maximum of 11 waveforms
Ukuran Dimensi : 344 mm (Weight) × 266 mm (Height) × 145 mm (Depth)
Berat : 5 kg
Power supply : 100 V to 240 V~, 50 Hz/60 Hz
Battery life : 350 min (At 25±2 C, with (a) new fully charged
Battery charge time : ≤ 390 min, 100% charge
SUPPORTED PARAMETER
ECG
Lead mode (optional 3 or 5 lead) : 3-lead : I, II, III
Heart rate calculation
Range : ADU: 15 to 300 bpm
: PED/NEO: 15 to 350 bpm
PVC
Range : ADU: 0 to 300 PVCs/min
: PED/NEO: 0 to 350 PVCs/min
ST value
Range : –2.0 to 2.0 mV
RESPIRATION

Method : Impedance between RA-LL, RA-LA


Measurement lead : Default lead II
Measurement Range
Adult : 0 to 120 rpm
Neo/Ped : 0 to 150 rpm
Sweep : 6.25 mm/s, 12.5 mm/s, 25mm/s, 50mm/s
Apnea Alarm time setup : 10s, 15s, 20s, 25s, 30s, 35s, 40s, default is 20s
NIBP

Method : Oscillometric
Mode : Manual, Auto, Continuous
Measuring interval in auto mode : 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 240, and 480 min
Continuous : 5 min, interval is 5 s
Measuring type : Systolic Pressure, Diastolic Pressure, Mean Pressure
Alarm type : SYS, DIA, MAP
Pulse Rate
Measuring range : 40 to 240 bpm
Accuracy : ±3 or 3.5 %, whichever is larger
SpO2
Measuring range : 0 to 100 %
Resolution : 1%
TEMPERATURE

Technique : thermal resistance

Position : Skin
IBP : dual invasive pressure

Technique : Direct Invasive measurement


Measuring range
Art : 0 to 300 mmHg
PA : -6 to 120 mmHg
CVP/RAP/LAP/ICP : -10 to 40 mmHg
P1/P2 : -50 to 300 mmHg
CO2
Measure parameter : EtCO2,FiCO2, AwRR
Unit : mmHg, %, kPa

Measuring range

CO2 : 0 to 100 mmHg


FiCO2 : 0 to 100 mmHg
Cardiac Output (C.O)

Technique : Thermodilution Technique


Measure Parameters : C.O, TB, TI
Trend review
Short : 1 hr, 1 s. resolution
Long : 120 hrs, 1 min. resolution
Review : 1200 sets NIBP measurement data

RECORDER

Record width : 48 mm
Paper speed : 12.5 mm/s 25 mm/s, 50 mm/s
Trace : Up to 3 waveforms
Accessories
ECG Cable : 1 pc
ECG ELECTRODE : 1 pc
NIBP cuff : 1 pc
SpO2 SENSOR : 1 pc
Skin temp probe : 1 pc
Printing paper : 1 pc
IBP Cable : 2 pc
etCO2 KIT : 1 pc
Cardiac Output (C.O) : 1 pc