Arrêter SIS
Ecran précédent
Produit: EXCAVATOR
Modèle : 345D L EXCAVATOR YEE
Configuration: 345D L Excavator YEE00001-UP (MACHINE) POWERED BY C13 Engine
Essai et réglage
345D, 349D and 349D2 Excavators Hydraulic System
Numéro d'imprimé -KENR6775-10 Date de publication -01/04/2014 Date de mise à jour -10/04/2014
i05765253
Table 1
Required Tools
Part Number Description Qty
9U-7400 Multitach Tool Group 1
NOTICE
Speed Calibration
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 19/11/2019
345D L Excavator YEE00001-UP (MACHINE) POWERED BY C13 Engine(SEBP5... Page 2 of 4
Illustration 1 g01318417
(1) Up key
(6) OK key
3. Release the pressure in the hydraulic system. Refer to Testing and Adjusting, "Hydraulic
System Pressure - Release".
4. Install 9U-7400 Multitach Tool Group on the fan for the hydraulic oil cooler.
Note: Certain machines will default to "Economy Mode" at machine startup. Change to
"High Hydraulic Power Mode" before performing the test procedure.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 19/11/2019
345D L Excavator YEE00001-UP (MACHINE) POWERED BY C13 Engine(SEBP5... Page 3 of 4
6. Place the machine controls at the following settings: AEC switch OFF and engine speed dial
"10".
ReferenceRefer to Testing and Adjusting, "Engine Performance - Test (Engine Speed)" for
engine rpm settings.
7. With the hydraulic oil below 48 °C (118 °F), set the fan speed.
a. Start Service Mode in order to adjust the speed of the fan motor.
c. Input the password "FFF2". Press left key (2) or right key (4) in order to change the
character. Press OK key (6) or press cancel key (5) in order to delete the value of the
flashing character. Press OK key (6) after the correct password is displayed.
d. Press left key (4) repeatedly until "CALIBRATIONS" appears on the message
display. Press OK key (6) .
e. Press down key (3) in order to move down the cursor until the "FAN SPEED"
message display is highlighted.
f. Press OK key (6) in order to select the "FAN SPEED" message display.
g. Set the lower speed limit with left key (2) and right key (4) . Press OK key (6) when
the minimum fan speed meets the requirements of Table 2.
Table 2
Minimum Fan Speed
670 ± 30 rpm (1)
(1)
Standard specification
h. Adjust the upper fan speed with left key (2) and right key (4) . Set the speed to 1175 ±
30 rpm.
i. Press the OK key (6) when the upper speed is at the specified value of 1175 ± 30 rpm.
j. Press set key (7) in order to return the monitor to the main menu.
9. Measure speed of the fan in order to verify that the upper value is met. Use step 7.a through
step 7.g in order to recalibrate the fan speed if the upper speed requirements are not met.
10. After the hydraulic oil falls to 48° ± 1°C (118° ± 2°F), measure the fan speed again. Verify
the minimum fan speed. Use step 7.a through step 7.g in order to recalibrate the fan speed if
the minimum requirements are not met.
Copyright 1993 - 2019 Caterpillar Inc. Tue Nov 19 00:26:34 UTC 2019
Tous droits réservés.
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 19/11/2019
345D L Excavator YEE00001-UP (MACHINE) POWERED BY C13 Engine(SEBP5... Page 4 of 4
https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sis... 19/11/2019