Professional Documents
Culture Documents
HAZOP Report
HAZOP Report
5 Catastrophic
Loss of Platform,
Longlasting Environmental
Damage
4 Major
Signicicant Equipemnt and
long environment damage
3 Severe
Require clean up
Lost-time injury
2 Minor
Reoprtable injury and release
maintenance repair
1 First AID Case
Emergency shut everything
down
A B C D E
Happen Rate (Never threat of 1/1,000 years in 1/1000 years in 1/10years in 1/1years in
industry) 1/10,000 industry (might industry (might industry (Likely ) industry (Multiple
years in industry Happen ) Happen ) Times)
code that has been used in the following tables.
Less -Pump Failure -Change in Product - Valves connect -Valves and -Install Flow meter and Low 4D
Flow ot -Manual Valve Quality and with computer flow meter level alarm
less closed concentration program and make should be -Make a low level warning
level it visible from the examined on main distillation column
-Tube leakages or
control room
blocking
-Low level Alarm
Over -Control valve -Change in Product -Automatic closed Emergency Install High level alarm 4D
Flow or failure or valve is Quality and control valve while case -Make by pass
high fully opened concentration the flow reach
- Emergency Plant shut
level -Column Capacity -Flooding in the certain level
down
Exceeded column -High level alarm
High -Malfunctioning stem -Accumulation in Temperature probe Emergency -Lower reboiler duty 4B
utility
File Name:XXXXXXXXXXX Coarse HAZOP rev X 5
Tempera column in reboiler Case
ture -Poor separation
Low -Malfunctioning stem -Poor Separation Temperature probe Emergency -Increase reboiler duty 4B
Tempera utility in reboiler Case
ture
Unit Mechanical Wear Combustion of hot Gas detector Emergency Emergency shutdown 1D
Leak vapors can lead to installation and Case Operation evacuation
loss of life plant ventilation
system
Unit Mechanical Wear Exposure of Annual Emergency Emergency shutdown 1C
Rupture combustible gases to maintenance check case Operation evacuation
air and leads to loss
of life
High -Malfunctioning steam -Accumulation in Temperature probe Emergency -Lower condenser duty 4C
Tempera utility column in reboiler Case
ture -Poor separation
Low -Malfunctioning steam -Poor Separation Temperature probe Emergency -Increase condenser duty 4C
Tempera utility in reboiler Case
ture