Professional Documents
Culture Documents
GENERAL CAB Catalogo-2021 Finale PER-WEB
GENERAL CAB Catalogo-2021 Finale PER-WEB
PRODUCT CATALOGUE
HIGH PERFORMANCE FANS AND BLOWERS
Applications| Applicazioni 3
General Cab Group is an Italian organization established in 1982, based in Asti, North-West of Italy. General Cab Group is a
manufacturer of electric motor fans since the early 90’s and especially during the last 10 years General Cab Group has more
and more specialized its know-how in the development of high-tech solutions, both for axial and centrifugal ventilation.
General Cab Group technical competence consists of the development of solutions with axial fans and centrifugal blowers,
including the design of innovative fan blades and impeller wheels, as well as of the DC 12V 24V 48V electric motors fitted onto
the cooling fans and centrifugal blowers.
General Cab Group develops and manufactures electric fans for any kind of application, merging the experience and the
various different technical characteristics, required by each single application, such as durability of the product,
protection-water proofing, internal ventilation, guard and screening from radio interference.
The production is mostly developed internally: in addition to the assembly and test of the electric motors and complete fan
modules, General Cab Group is fully equipped and able to manufacture rotors and brush-holders (key components of any
electric motor), as well as all plastic parts are injected “in house”, even and especially plastic fan blades, conveyors, grids, big
dimension shrouds.
General Cab Group è un’organizzazione italiana operante dal 1982, con sede ad Asti, Piemonte, Italia.
General Cab Group sviluppa soluzioni dedicate e produce elettroventilatori funzionanti a corrente continua fin dai primi anni
90 e negli ultimi 10 anni si è sempre più specializzata anche nello sviluppo di progetti tecnici che utilizzano elettroventole
assiali e centrifughe.
Sono parte del patrimonio di General Cab Group le competenze tecnologiche per lo sviluppo delle ventole, a cominciare
dalla definizione della sezione di pala, così come di motori elettrici a corrente continua 12V 24V 48V.
General Cab Group sviluppa e produce elettroventilatori per tutti i campi di applicazione, avendo cura di fondere al meglio
l’esperienza e le prerogative tecniche che i vari campi di applicazione inducono ad approfondire, durata, protezione tenuta
ai fluidi, ventilazione interna dei motori elettrici, schermatura contro disturbi radio.
La produzione è significativamente verticalizzata: oltre alle operazioni di assemblaggio e collaudo dei motori elettrici e degli
elettroventilatori completi, General Cab Group è del tutto autonoma nella produzione degli indotti e dei portaspazzole
(componenti chiave dei nostri motori elettrici), così come nello stampaggio e co-stampaggio per iniezione, di componenti
plastici, in particolare ventole, griglie, coclee e convogliatori, anche di grandi dimensioni.
Air conditioning for buses, trucks, tractors and heavy duty vehicles. Ventilation on livestock trailers, car radiator cooling, heat
exchangers cooling.
Condizionamento aria per autobus, camion, trattori e veicoli speciali. Ventilazione veicoli trasporto animali vivi,
raffreddamento radiatori, raffreddamento scambiatori di calore.
Part Numbers - Products are characterized one from the other by a 8 digit number. The main families are:
Each product variation causes a new product Part Number. Every axial fan motor you find in our catalogue has a
standard AMP Tyco C-180908 connection. Centrifugal fan motors have male terminals (AMP Tyco 42098). Each product
con be equipped with a specific connector according to Customer request.
Codici - I prodotti General Cab sono contraddistinti l'uno dall'altro mediante un CODICE di 8 cifre.
Le principali famiglie sono:
Qualsiasi variante di prodotto dà origine ad un nuovo codice articolo. Tutti gli elettroventilatori assiali elencati nel
catalogo utilizzano il connettore standard tipo AMP Tyco C-180908. Per i prodotti centrifughi la dotazione standard è il
terminale maschio (AMP Tyco 42098). Qualsiasi articolo può essere dotato di un connettore specifico a richiesta del
Cliente.
We have a range of different fan diameters and each of them con be combined with a different electric motor. AII this
generates a wide range of power and lengths: we have 8 different electric motors, to which correspond different axial
lengths and power levels. For each power range we con offer four fan motor versions, combining the following features:
Esiste una scelta di vari diametri ventola, ciascuno di essi può essere combinato con tipi differenti di motore elettrico.
Tutto ciò produce una vasta gamma di potenze e di possibili ingombri: disponiamo di 8 tipi diversi di motore elettrico, a
cui corrispondono svariate altezze assiali e taglie di potenza.
A parità di taglia di potenza sono inoltre disponibili quattro versioni, combinando le seguenti possibili caratteristiche:
These fan motors are mainly divided between 12 and 24 Volts but they differ one from the other also for plastic shape,
dimensions and fixing points to mounting systems.
In the range of one single shape (or geometry) it is possible to install different electric motor versions to which correspond
different performances (for example motor life, motor power, etc.).
Optionally the products may be equipped with resistor to 2-3 ohmic values with or without wiring (see page 83).
Questi elettroventilatori sono principalmente divisi in 12 o 24V, ma differiscono tra loro anche per la forma e per le dimensioni
delle coclee e delle flange con cui vengono raccordati ai condotti dei sistemi sui quali vengono montati.
Nell'ambito di una singola forma (o geometria) è possibile installare tipi diversi di motore elettrico, a cui corrispondono
prestazioni diverse (a titolo di esempio, durata in ore, potenza, ecc.).
Opzionalmente i prodotti possono essere dotati di resistore a 2-3 valori ohmici con e senza cablaggio (vedere pag. 83).
It is customer’s responsibility to verify that the product is used according to technical specifications reported in this catalog.
The motor must be protected by a fuse according to catalogue data to protect the power system and also the fan. Install
one fuse for each electric fan.
È responsabilità del cliente verificare che il prodotto individuato sia impiegato secondo le specifiche tecniche riportate sul
catalogo. L’elettroventilatore deve essere protetto da un fusibile di adeguato valore a protezione del sistema di
alimentazione e dell’elettroventilatore stesso. Si raccomanda l’installazione di un singolo fusibile per ogni elettroventola.
If the electric fan motor is used horizontally with the fan pointed downwards, it is recommended to utilize perforated fans for
the water drainage (see the picture below).
Nel caso di impiego dell’elettroventilatore in posizione orizzontale con la ventola rivolta verso il basso si consiglia l’utilizzo di
ventole forate per il drenaggio dell’acqua (riferimento all’immagine sottostante).
LIFECYCLE | DURATA
The electric fan motors life is closely connected to the point in which they work, following and observing the conditions of use
and the proper/correct electric power. This electric power must have a direct, rectified and stabilized current with a
maximum remaining ripple of 1%. On request our company supplies information about the lifetime of our products, with
accelerated wear testing, realized with a testing protocol according to the use and the conditions of installation. The lifetime
of the electric fan motors depends on the environmental temperature that must be between -30 °C and 80 °C max. If there
are other temperatures of application please contact our technical office.
La durata degli elettroventilatori è strettamente legata al punto di funzionamento al quale essi lavorano nel rispetto delle
condizioni di utilizzo e dalla corretta tensione di alimentazione, la quale deve avere una corrente continua raddrizzata e
stabilizzata con un ripple massimo residuo dell’1%. La General Cab fornisce su richiesta indicazioni sulle durate dei propri
prodotti determinate attraverso test di usura accelerata, realizzati secondo un protocollo di prova e riferite al punto di lavoro
riferito alle condizioni di installazione del cliente. La durata è anche condizionata dalla temperatura ambiente che deve
essere compresa tra i -30 °C e i 80 °C max. Per valori diversi di temperatura si prega di contattare il nostro ufficio tecnico.
During product definition, the parts are submitted to certified laboratories in order to perform the tests with the aim to
understand if they are compliant to the most common EMC compatibility standards (EU directive 2006\28\EC). When
necessary, we provide for specific components needed to lower the electromagnetic level, that an electric motor generates
during functioning, meeting the strictest requirements of specifications, such as for military applications.
Nel corso dello sviluppo del prodotto, gli elettroventilatori vengono sottoposti a test presso laboratori accreditati per
verificare che rispettino gli standard di compatibilità elettromagnetica previsti dalla direttiva europea 2006\28\EC. Quando
necessario, si provvede a dotare i motori dei componenti specifici in grado di abbattere il disturbo elettromagnetico
generato dal motore elettrico durante il funzionamento andando anche a soddisfare i limiti dei capitolati più severi come ad
esempio quelli delle applicazioni militari.
All General Cab products are guaranteed 36 months against manufacturing defects and such period shall run from the
manufacturing date. The warranty is valid only if the following conditions are met:
1. The label that identifies the product must be present with no signs of alteration.
2. The product must be complete and without any sign of tampering or modification.
Note:
The warranty is valid only for manufacturing defects, so it is excluded for product malfunction caused by improper installation
or damage incurred during installation or transportation. The warranty is valid only for the intended use of the specific
operating conditions. The warranty is excluded for failures due to normal wear and tear.
General Cab reserves the right to recognize the warranty of the product also with the inspection by its technicians.
In case of recognition of the warranty conditions, General Cab will proceed with the replacement of the product only,
without accepting any additional costs.
Tutti gli elettroventilatori General Cab sono garantiti 36 mesi da difetti di fabbricazione e tale termine decorre dalla data di
produzione. La garanzia è da ritenersi valida solo se sono soddisfatte le seguenti condizioni:
1. L’etichetta che contraddistingue il prodotto deve essere presente senza arrecare segni di alterazione.
2. Il prodotto deve essere integro e senza alcun segno di manomissione o modifica.
Nota:
La garanzia è valida solo per i difetti di fabbricazione, per cui viene esclusa per malfunzionamenti del prodotto causati da
installazioni inappropriate o da danni subiti durante il montaggio o il trasporto.
La garanzia è valida soltanto per l'uso previsto dalle specifiche condizioni di funzionamento. Restano esclusi i
malfunzionamenti causati dalla normale usura.
La General Cab si riserva il diritto di riconoscere la garanzia del prodotto anche a seguito di una propria visita ispettiva da
parte dei suoi tecnici. Nel caso di riconoscimento delle condizioni di garanzia, la General Cab procederà alla sostituzione del
solo prodotto e non saranno presi in carico altri costi aggiuntivi.
Each form contains four P/Ns. These products are shown a single page because they have quite the same power in Watts.
They differ one from the other according to the following possible four options:
As already underlined, the 8 digits P/N linked to the products in the form refer to electric fan motors with AMP C-180908
connector (except where otherwise indicated). To these same fan motors are linked new and different P/N if they are fitted
with different connectors (between the optional ones or on specific Customer request). In this case we recommend to ask for
standard P/N you find on the catalogue with the specific indication of the connector needed: we will check availability and
feasibility and communicate the new P/N linked to the specific optional connection required.
Ciascuna scheda raggruppa 4 articoli: a parità di altre caratteristiche, questi articoli sono riportati su una sola pagina perché
hanno in comune la taglia di potenza in Watt. Differiscono invece per le seguenti quattro possibili combinazioni:
A) 12 V aspirante B) 12 V soffiante
C) 24 V aspirante D) 24 V soffiante
Come già evidenziato, i codici a 8 cifre abbinati agli articoli della scheda si riferiscono agli elettroventilatori corredati di
connettore tipo AMP C-180908 tranne nei casi particolari evidenziati in calce.
Agli stessi ventilatori possono essere abbinati nuovi e diversi codici se vengono richiesti con altri tipi di connettore (a scelta tra
quelli opzionali o su specifica cliente).
In tal caso si raccomanda di individuare l’elettroventilatore base attraverso il codice a 8 cifre riportato a catalogo,
accompagnandolo con l’indicazione specifica del connettore opzionale desiderato: sarà nostra cura processare la richiesta
(ordine o preventivo) e comunicare il codice articolo di 8 cifre valido per indicare univocamente la personalizzazione
richiesta.
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
19
Centrifugal fan motors are presented in the catalogue with the aim to join inside each single form a couple of products with
common power, one with 12 Volt motor, the other with 24 Volt motor.
P/Ns are related to base products, without multi-speed resistor and with standard male terminals (unless otherwise stated).
Existing P/Ns equipped with multispeed resistors are shown on the bottom of the page.
Multi speed resistors with 2 or 3 ohmic value are available on request (see page 83).
It is necessary to specify the basic product P/N in the Customers requests (orders or RFQs), indicating, if needed, a connector
type and/or an optional resistor requested.
The performance data (air flow and current) refer to maximum speed functioning without resistor operation. The
performances at middle speed can be supplied upon request on the basis of the resistor required.
I ventilatori centrifughi sono presentati nel catalogo in modo da raggruppare su ogni singola scheda una coppia di prodotti
aventi la stessa potenza, ma diverse tensioni di alimentazione (12 V / 24 V).
I codici articolo si riferiscono ai prodotti base, ovvero privi di resistore multi velocità e dotati di terminali maschi (salvo ove
espressamente indicato). I codici prodotto esistenti con resistori a più velocità sono indicati in calce.
A richiesta sono disponibili resistori multi velocità a 2 o 3 valori Ohmici e connettori opzionali (vedi pag. 83).
Nelle richieste (ordini o preventivi) occorrerà specificare il codice articolo del prodotto base, accompagnato, se di interesse,
dal tipo di connettore e/o resistore opzionale prescelto.
I dati di prestazione (portata d’aria e assorbimento) si riferiscono al prodotto funzionante alla massima velocità, senza
l’intervento di resistori. Le prestazioni a velocità intermedie possono essere fornite su richiesta, a seconda del resistore
prescelto.
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 13V D.C. - Tensione di prova 13V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inchH2O - 1 mmH2O = 9,81 Pa
General Cab has recently developed a new electric motor family with exclusive technical characteristics with the aim to
meet the highest performance requirements of Automotive Industry, "highway" and "off-highway". The GC 87xx family is
distinguished by having a very long durability, it has a casing made completely in steel, it is compact with smaller than
average dimensions, even in the larger sizes, it has the possibility to comply with the strictest EMI standards, thanks to different
level of filtering, matching also the highest MIL military standards.
The entire new family of GC 87xx electric motors, like all General Cab products, can be modified according to the most
demanding requests of the Customer, responding to the requirements of the most stringent specifications.
La nuova famiglia di motori elettrici sviluppati in esclusiva da General Cab nasce per rispondere alle esigenze prestazionali
più elevate, dei settori Automotive “highway” ed “off-highway”. La famiglia GC 87xx si distingue per avere una lunghissima
durata, per avere una carcassa esterna completamente in acciaio, per la compattezza degli ingombri anche nelle taglie
più grandi, per la capacità di poter raggiungere livelli di filtratura EMI basati sugli standard militari MIL.
Tutta la nuova famiglia di motori elettrici GC 87xx come tutti i prodotti di General Cab possono essere modificati secondo le
più esasperate richieste del Cliente, rispondendo alle esigenze dei capitolati più severi.
10
8608
Motor height | Altezza motore = 52 mm
8612
Motor height | Altezza motore = 63 mm
8622
Motor height | Altezza motore = 81 mm
8630
Motor height | Altezza motore = 90 mm
* p roducts are also available on demand with the new motor family 87xx
i prodotti sono disponibili su richiesta con la nuova famiglia motori 87xx
11
12
13
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
15
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
16
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
17
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
18
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
19
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
20
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
21
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
22
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
23
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
24
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
25
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
26
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
27
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
28
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
29
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
30
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
31
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
32
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
33
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
34
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
35
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
36
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
37
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
38
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
39
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
40
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
41
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
42
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
43
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
44
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
45
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
46
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
47
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
48
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
49
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
50
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
51
Static Static
Pressure Pressure
Pressione Airflow Current Airflow Current Pressione Airflow Current Airflow Current
Statica Portata Corrente Portata Corrente Statica Portata Corrente Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria : 1 m3/h = 0,59 cfm - Static pressure - Pressione : 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
52
summary 90050161
90050164
167
190
8608
8608
extra flat
extra flat
15
16
(ordered by code)
90050165 190 8608 extra flat 16
90050168 225 8608 extra flat 17
90050169 225 8608 extra flat 17
Sommario per 90050172
90050173
255
255
8608
8608
extra flat
extra flat
21
21
Assiali 90050180
90050181
305
305
8608
8608
extra flat
extra flat
35
35
90050184 385 8608 extra flat 49
90050185 385 8608 extra flat 49
90050188 280 8612 extra flat 27
90050189 280 8612 extra flat 27
90050192 305 8612 extra flat 36
90050193 305 8612 extra flat 36
90050196 385 8612 extra flat 50
90050197 385 8612 extra flat 50
90050208 280 8608 extra flat 26
90050209 225 8608 extra flat 18
90050220 225 8608 extra flat 18
90050223 255 8608 extra flat 22
90050224 255 8608 extra flat 22
90050228 350 8608 extra flat 44
90050229 350 8608 extra flat 44
90050232 350 8612 extra flat 45
90050233 350 8612 extra flat 45
90050268 280 8608 extra flat 26
90050356 385 8622 extra flat 52
90050371 385 8622 extra flat 51
90050383 385 8622 extra flat 52
90050384 350 8622 extra flat 48
90050385 255 8612 extra flat 23
90050388 255 8612 extra flat 23
90050409 385 8622 extra flat 51
90050422 305 8622 HEAVY DUTY without fingerguard 40
90050423 305 8622 HEAVY DUTY without fingerguard 43
90050428 305 8622 HEAVY DUTY without fingerguard 39
12 V
90050429 305 8622 HEAVY DUTY with fingerguard 41
90050433 305 8622 HEAVY DUTY without fingerguard 42
90050435 305 8622 HEAVY DUTY without fingerguard 43
90050436 305 8622 HEAVY DUTY without fingerguard 39
90050437 305 8622 HEAVY DUTY with fingerguard 41
90050438 350 8622 extra flat 47
90050442 350 8622 extra flat 48
90050443 350 8622 extra flat 47
90050444 350 8622 extra flat 46
90050445 350 8622 extra flat 46
90050451 225 8622 extra flat 20
90050478 305 8612 extra flat 37
90050480 305 8612 extra flat 37
90050487 280 8612 extra flat 28
90050488 280 8612 extra flat 28
90050557 280 8630 HEAVY DUTY without fingerguard 30
90050558 280 8630 HEAVY DUTY without fingerguard 30
90050559 280 8622 HEAVY DUTY without fingerguard 31
90050560 280 8622 HEAVY DUTY without fingerguard 31
90050562 280 8622 HEAVY DUTY without fingerguard 32
90050563 280 8622 HEAVY DUTY with fingerguard 33
90050564 280 8622 HEAVY DUTY with fingerguard 33
90050566 280 8622 HEAVY DUTY with fingerguard 34
90050569 225 8622 extra flat 20
90050655 225 8612 extra flat 19
90050656 225 8612 extra flat 19
90050659 255 8622 extra flat 24
90050660 255 8622 extra flat 24
90050663 280 8622 extra flat 29
90050664 280 8622 extra flat 29
90050667 305 8622 extra flat 38
90050668 305 8622 extra flat 38
53
E
90050211 280 8608 extra flat 26
90050221 225 8608 extra flat 18
90050225 255 8608 extra flat 22
90050226 255 8608 extra flat 22
90050234 350 8612 extra flat 45
90050235 350 8612 extra flat 45
90050248 350 8608 extra flat 44
90050249 350 8608 extra flat 44
90050300 225 8608 extra flat 18
90050397 305 8622 HEAVY DUTY with fingerguard 41
90050408 385 8622 extra flat 52
90050412 385 8622 extra flat 51
90050413 385 8622 extra flat 51
90050418 305 8622 HEAVY DUTY with fingerguard 41
90050419 305 8622 HEAVY DUTY without fingerguard 40
90050420 305 8622 HEAVY DUTY without fingerguard 40
24 V
90050421 305 8622 HEAVY DUTY without fingerguard 43
90050424 305 8622 HEAVY DUTY without fingerguard 42
90050430 305 8622 HEAVY DUTY without fingerguard 42
90050431 305 8622 HEAVY DUTY without fingerguard 43
90050432 305 8622 HEAVY DUTY without fingerguard 39
90050434 305 8622 HEAVY DUTY without fingerguard 39
90050440 350 8622 extra flat 48
90050441 350 8622 extra flat 48
90050446 350 8622 extra flat 46
90050447 350 8622 extra flat 46
90050448 350 8622 extra flat 47
90050468 385 8622 extra flat 52
90050479 305 8612 extra flat 37
90050481 305 8612 extra flat 37
90050493 280 8612 extra flat 28
90050494 280 8612 extra flat 28
90050547 280 8622 HEAVY DUTY without fingerguard 31
90050548 280 8622 HEAVY DUTY without fingerguard 31
90050549 280 8630 HEAVY DUTY without fingerguard 30
90050550 280 8630 HEAVY DUTY without fingerguard 30
90050551 280 8622 HEAVY DUTY without fingerguard 32
90050552 280 8622 HEAVY DUTY without fingerguard 32
90050553 280 8622 HEAVY DUTY with fingerguard 33
90050554 280 8622 HEAVY DUTY with fingerguard 33
90050555 280 8622 HEAVY DUTY with fingerguard 34
90050556 280 8622 HEAVY DUTY with fingerguard 34
90050561 255 8612 extra flat 23
90050565 255 8612 extra flat 23
90050567 225 8622 extra flat 20
90050568 225 8622 extra flat 20
90050657 225 8612 extra flat 19
90050658 225 8612 extra flat 19
90050661 255 8622 extra flat 24
90050662 255 8622 extra flat 24
90050665 280 8622 extra flat 29
90050666 280 8622 extra flat 29
90050669 305 8622 extra flat 38
90050670 305 8622 extra flat 38
54
90070061 VVHP 59
90070063 VVHP 60
90070065 VVHP 61
BORA 90070089 SP 62
90070069 VVHP 63 BORA
90070091 SP 64
90070071 VVHP 65
90070182 SSP 67
90070183 SSP 68
ZEPHIR
90070178 SSP 69
90070179 SSP 70
MISTRAL
90070138 SP 71
90070106 VVHP 72
90070141 SP 73
90070109 VVHP 74
BLIZZARD
90070144 SP 75
90070112 VVHP 76
90070043 SP 77
90070100 VVHP 78
ZEPHIR
BRIZA 90040125 8622 79
24 V
model part number motor page
90070187 VVHP 59
90070188 VVHP 60
90070067 VVHP 61
BORA 90070095 SP 62 BLIZZARD
90070075 VVHP 63
90070097 SP 64
90070077 VVHP 65
90070029 SSP 67
90070184 SSP 68
ZEPHIR
90070180 SSP 79
90070181 SSP 70
90070155 SP 71
90070123 VVHP 72
90070158 SP 73
BRIZA
BLIZZARD 90070126 VVHP 74
90070161 SP 75
90070129 VVHP 76
Note:
90070164 SP 77
SSP = small power
90070132 VVHP 78
SP = standard power
BRIZA 90040123 8622 79 VVHP = high power
57
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
66
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
67
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
68
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
69
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
70
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
Static Static
Pressure Pressure
Airflow Current Airflow Current
Pressione Statica Portata Corrente Pressione Statica Portata Corrente
Test voltage 13V D.C. - Tensione di prova 13V C.C. Test voltage 26V D.C. - Tensione di prova 26V C.C.
Airflow - Portata d'aria: 1 m3/h = 0,59 cfm - Static pressure - Pressione: 1 mmH2O = 0,04 inH2O - 1 mmH2O = 9,81 Pa
79
90040125 8622 79
90070043 SP 77
90070061 VVHP 59
90070063 VVHP 60
90070065 VVHP 61
90070069 VVHP 63
90070071 VVHP 65
90070079 VVHP 66
90070089 SP 62
90070091 SP 64
12 V 90070100
90070106
90070109
VVHP
VVHP
VVHP
78
72
74
90070112 VVHP 76
90070138 SP 71
90070141 SP 73
90070144 SP 75
90070178 SSP 69
90070179 SSP 70
90070182 SSP 67
90070183 SSP 68
90040123 8622 79
90070029 SSP 67
90070067 VVHP 61
90070075 VVHP 63
90070077 VVHP 65
90070080 VVHP 66
90070095 SP 62
90070097 SP 64
90070123 VVHP 72
90070126 VVHP 74
24 V 90070129
90070132
90070155
VVHP
VVHP
SP
76
78
71
90070158 SP 73
90070161 SP 75
90070164 SP 77
90070180 SSP 79
90070181 SSP 70
90070184 SSP 68
90070187 VVHP 59
90070188 VVHP 60
80
Stand-by current: 4 mA
Corrente di Stand-by: 4 mA
Thermostat: On-Off signal (2 wires) – the duty cycle start from 0 to 100% in 15s
Termostato: Segnale On-Off (2 fili) – il controllo parte da 0 to 100% in 15s
PWM: Input signal with self-detective 0,1 – 5 KHz with level 5 - 28 V (LOW SIDE and HIGH SIDE)
PWM: segnale in auto apprendimento da 0,1 ÷ 5 KHz con livello da 5 ÷ 28 V (LOW SIDE and HIGH SIDE)
Analogic 0-10 Volts: (Under 0,8 V the fan is OFF, after it is proportional to the duty cycle, 1 V = 10% duty / 9,5 V = 100% duty)
Analogico 0-10 Volts: (sotto 0,8 V l’ELV è in OFF, dopo è proporzionalemente contollo da 1 V = 10% duty / 9,5 V = 100% duty)
NTC sensor: The speed control by the temperature, (Proportional Control) - Standard temperature range will be fixed on the range 40 °C – 80 °C
Sensore NTC: Il controllo della velocità è in funzione della temperatura. Il range di temperatura è fissato da 40 °C ÷ 80 °C
OPTIONAL
Lin bus communications (with dedicated firmware) | Lin bus (con Firmware dedicato)
Can bus communications (with dedicated firmware) | Can bus (con Firmware dedicato)
Protection against Reverse Polarity - V Battery Normal operation of the electric fan
Protezione contro l’inversion di polarità Funzionamento normale dell’elettroventola
81
Supply voltage power module control (V. batt.) | Connessione all’alimentazione regolatore (V batt.)
The NTC temperature probes are available upon request and can be connected directly to the speed regulator with
thread M14 or M22.
Sono disponibili le sonde di temperature NTC da collegare direttamente al regolatore di velocità con filetto M14 o M22.
The speed controller has multiple functions that in this documentation are not highlighted, please contact our staff for
further information and request.
Il regolatore di velocità ha molteplici funzioni di cui la presente documentazione non ne da evidenza, si prega di
contattare il nostro personale per approfondimenti e richieste.
82
Connectors
Waterproof series Serie stagna | Connettori
DELPHI metri-pack series 280 (15300002) DELPHI metri-pack series 630 (15363993) TYCO AMP sealed (C_282104)
GC p.n. 8021.0005 GC p.n. 8021.0006 GC p.n. 8021.0007
Connectors
|
Standard series Serie standard
Connettori
83
This catalogue includes all axial fans and centrifugal blowers item codes currently in production.
General Cab Group is open to differentiate products listed in this catalogue; such needs and requests have to be
forwarded to following contact details.
General Cab has the right at any time of changing information and/or technical details of this document
without any notice or any information.
General Cab srl si riserva il diritto di modificare in qualsiasi momento informazioni e/o dati tecnici del presente
catalogo senza obbligo di notifica o preavviso.
GCPRDCTLG201809-001