Professional Documents
Culture Documents
Micropile Design 2021-07-14
Micropile Design 2021-07-14
Micropile Design 2021-07-14
071 m2
Factor of Safety (FoS) = 2.0 Pile Capacity (kN)
Unit Skin Cumulative End Bearing at Pile Ultimate Pile Allowable 0 2000 4000
Depth Interval Avg SPT Skin Friction, End Bearing at 0.00
Friction (fs) Skin Friction, Depth, Capacity, Qult = Capacity, Qall =
(m) Value, N Fs (kN) depth, Qb (kN)
(kN/m2) Fs (kN) qb=(kN/m2) Fs+Qb (kN) Qult/FoS (kN)
Depth (m)
17.00 70 140 132 2243 0.0 0.0 2243 1122
20.00
18.00 70 140 132 2375 0.0 0.0 2375 1188
19.00 70 140 132 2507 0.0 0.0 2507 1253
20.00 70 140 132 2639 0.0 0.0 2639 1319
21.00 70 140 132 2771 0.0 0.0 2771 1385
25.00
22.00 70 140 132 2903 0.0 0.0 2903 1451
23.00 70 140 132 3035 0.0 0.0 3035 1517
24.00 70 140 132 3167 0.0 0.0 3167 1583
25.00 70 140 132 3299 0.0 0.0 3299 1649 30.00
26.00 70 140 132 3431 0.0 0.0 3431 1715
27.00 70 140 132 3563 0.0 0.0 3563 1781
28.00 70 140 132 3695 0.0 0.0 3695 1847
29.00 70 140 132 3826 0.0 0.0 3826 1913 35.00
30.00 70 140 132 3958 0.0 0.0 3958 1979