SL-WPSR
About 2x2 MIMO SDR for SAW Sensor Applications
Sensor Products and ▪ Software Defined Radio 2x2 MIMO hardware platform
Designs ▪ Supports three ISM bands - 433MHz, 915MHz and 2.45GHz.
▪ Multiple wireless SAW sensors interrogation system.
Timing Products and
▪ All functions controllable from software
Designs
▪ Independent synthesizers for TX and RX
Contact us ▪ Split-frequency operation and fast PLL lock time
▪ Adjustable transmit power
▪ FPGA, DSP, USB
1 of 3 26/01/2024, 23:10
Stratum Logic LLC http://stratum-logic.com/sensor_products.html
SL-MCFZ
Monolithic Crystal Filter Impedance Measurements
▪ Impedance range: 0-500kΩ +/-1%;
▪ Signal Generator: 0-10MHz in-phase (I) and quadrature (Q)
▪ Frequency resolution: 0.01Hz;
▪ Low noise downconversion to DC with Gilbert Cell
▪ 24 bit resolution analog-digital converter (ADC)
▪ Precise phase control of the LO DDS
▪ DSP
▪ CAN
The circuitry is designed for very harsh environment to measure real and
imaginary part of impedance ranging from 0Ω to 100kΩ within adjustable
frequency bandwidth. The device uses narrow-band direct conversion architecture.
Highly accurate measurements of the amplitude and phase dependent DC voltage
is obtained using a Gilbert Cell, a high resolution analog-digital converter (ADC),
and precise phase control of the LO DDS. The calculations of impedances are
performed in 32 bit microcontroller. High accuracy temperature measurement
circuitry is implemented using PT1000. The proposed circuitry is used to measure
impedance of MCF (Monolitic Crystal Filter) sensor for viscosity.
For more details about the desing contact Stratum Logic info@stratum-logic.com
SL-FCD
Fluid Conductivity and Dielectric Constant Measurements
▪ Conductivity range: 1000pS/m to 5000000pS/m;
▪ Dielectric constant range: 0-40 ε0.
▪ PT1000 temperature sensor -5C to 125C
2 of 3 26/01/2024, 23:10
Stratum Logic LLC http://stratum-logic.com/sensor_products.html
The circuitry is designed for very harsh environment to measure very high
resistance and low capacitance of a liquid. The device is based on a relaxation
oscillator circuit with a very low noise integrator measuring very low current and
two high speed comparators. Additional logic gate is used to create signal with
pulses proportional to measured resistance and capacitance. Conductivity and
dielectric constant of liquid placed between the sensor electrodes is calculated in a
processor. In addition the circuitry uses direct sampling of the integrator voltage
and calculates resistance and capacitance more accurately. High accuracy
temperature measurement circuitry is implemented using PT1000 as liquid
conductivity typically greatly varies with temperature.
3 of 3 26/01/2024, 23:10