FIRST PERIODICAL TEST

ELECTRICAL INSTALLATION AND MAINTENANCE 11

REMEMBERING
Direction: Identify the given picture and classify what type of hazard it portraits.

1. 2. 3. 4.

5. 6. 7.

For items 8-12, Identify the names of the given measuring tools
-

8. 9. 10. 11. 12.

UNDERSTANDING

Direction: Read carefully and choose the letter that best fit the answer of the given. LETTERS ONLY statement.

13.They are designed to control hazard and maintain safety among construction workers.
a. signages b. PPE d. all of the above
14. This hazard sign is used only where an immediate hazard exists.
a. danger sign b. exit sign c. general sign
15. This is used as temporary means of warning of an existing hazard such as defected tools, equipment
a. traffic sign b. accidental prevention sign c. exit sign
16. Which among the following signs should be used to warn against or caution against practices?
a. wash hands with water
b. slippery when wet
c. no parking
17. What is the predominating color used for danger signages?
a. yellow b. green c. red
18. Which among the following signages has the yellow as the predominating color
a. exit sign b. general sign c. caution sign
19. It is a way of controlling hazard state of readiness is shown to minimize loss of life, injury, and damages.
a. safety b. emergency preparedness c. awareness
20. Which among the following materials does not belong to the group
a. flashlights, water, canned food
b. radio, batteries, medicine
c. softdrinks, headset, roll-on
21. These are equipment use for safety purposes.
a.Personal Protective Equipment
b. Electrical Materials and Tools
c. Electrical Equipment
22. This equipment is required to protect your hands from cuts, scrapes,
punctures, burns, chemical absorption, and exhaust temperatures.
a. Respirators b. gloves c. globe
23. It is used as an eye control measure against flying particles, chemicals and liquid.
a. googles b. respirators c. eyeglasses
24. What would result if you do not observe wearing of PPE in the work field.
a. Cuts and punctures
b. exposure to excessive noise or vibration
c. all of the above
25. This equipment is required when working around nails, wire tacks, scrap metals and other objects that
could fierce the feet of the workers
a. safety shoes b. steel toe c. none of the above

For items 26-30, put a checkmark (/) if the statement is correct, if not write the word that makes it
incorrect.
statement.
26 . Don’t clown around or engage in horseplay.
27. Report all injuries at once.
28. Keep the floors around your work area untidy.
29. Use pliers as hammer to straighten wires.
30. Wear all the PPE needed in this job.

APPLYING
Direction: ILLUSTRATE what type of splice is being describe in each item.

31. This is used as a temporary tap usually done in constructions sites. The easy twist will facilitate tap wire
movement. (EIARLA PAT)
32. This is the most widely used splice or joint in exterior wiring installation to extend the length of wire
from one point to another. (WULS)
33. The same application is done as in plain tap and the only difference is that this tap is a combination of
two plain taps place side by side with each other. (SSCRO OINJT)
34. If you want to prolong the wire inside a conduit. What splices you are going to use?(WUSS)
35. This is a two-tap wire turned simultaneously and is used where the two-tap wire is under heavy tensile
stress. (UPLXED OCSSR OINJT)
36. This kind of joint is commonly used to join two or more conductors inside the junction box. (ART
IALT)
37. This is used where the tap wire is under considerable tensile stress circuit. (AILPN APT)
38. This is used where the tap wire is under heavy tensile stress.( NOTTKED PAT)

For numbers 39-45, SEQUENCE the following steps in splicing using numbers.

RAT TAIL JOINT


__Then, twist the bare conductors using a long nose and plier
__Place the two ends of bare wire in crossed position.
__Strip/skin the wire insulator at the ends of the conductor to be joined at about 3 inches. Clean both wires to be
joined.

WESTERN UNION LONG- TIE SPLICE


__Wrap each side of the wire for about three to four turns.
__Make four to six long twists of wires
__Place the wires in crossed position about mid halfway from the insulation.
__Strip the wire ends for about 3 inches

EVALUATING

Evaluate the given situation.


Rafal, a worker at Abra Electric Cooperative had just finished installing a new system at an entire floor of a
building. He was tired working alone the whole afternoon. He usually leaves the cooperative at 5 in the afternoon.
Upon arriving home, he went straight to bed to relax himself. Do you think what he did is healthy and safe? What
techniques should be demonstrated to maintain safety?

Good things come to people who wait,


but better things come to those who go out and get them.
-Teacher FM

Name:__________________________________________ Date:____________
Year/Section:11 TVL - _____ Score: ________/50
FIRST PERIODICAL TEST ANSWER SHEET
EIM
NAME OF PICTURE CLASSIFICATION NAME OF PICTURE CLASSIFICATION
1. 5.
2. 6.
3. 7.
4.
NAME OF EQUIPMENT
8._________________________
9._________________________
10._________________________
11._________________________
12._________________________

31. 32. 33. 34.

35. 36. 37. 38.

Numbers(1-3) Numbers(1-4)
39. ____ 42._____
40. ____ 43._____
41. ____ 44._____
45._____

46-50.

_________________________________________________________________________________________
_________________________________________________________________________________________
_________________________________________________________________________________________
_________________________________________________________________________________________
____________________________________________________________________________________

You might also like