Download as pdf or txt
Download as pdf or txt
You are on page 1of 22

401 E.

Main Street 2885 Pa’a Street, Unit #206


Montrose, CO 81401 Honolulu, HI 96819
(970) 497-8200 Office (808) 836-9650 Office
(970) 497-8201 Fax

Repair Bucholz Army Airfield (BAAF)


U.S. Army Kwajalein Atoll
Republic of the Marshall Islands

Section 03 31 29
Marine Concrete

SD-02 Shop Drawing


1.8.2 Construction and Expansion Joints G
(reinforcing bars)

SD-03 Product Data


2.8.1 Reinforcing Bars G

SD-06 Test Reports


2.8.1 Reinforcing Bars To follow
401 E. Main Street 2885 Pa’a Street, Unit #206
Montrose, CO 81401 Honolulu, HI 96819
(970) 497-8200 Office (808) 836-9650 Office
(970) 497-8201 Fax

Repair Bucholz Army Airfield (BAAF)


U.S. Army Kwajalein Atoll
Republic of the Marshall Islands

Section 03 31 29
Marine Concrete

SD-02 Shop Drawing


1.8.3 Construction and Expansion Joints
(Reinforcing bars)
30' 30'-0.04" 30'-7.74"

17'-8.00"
21'-2.00"

21'-2.00"

26'-2.00"
14'-8.00"
6'-7.96"

9'
LEGEND:

10'-10.04"
13'-6.04"

1st POUR
2nd POUR
3rd POUR
4th POUR
5th POUR
16'-6.00"
6th POUR
23'-10.04"
7th POUR

CONSTRUCTION JOINT ON FOOTING

NAVAID BUILDING

Construction Joint on Footing


R - (4) #5 x 12'-11" Q - (4) #5 x 20' construction joint J - (4) #5 x 14'-8 1/4" I - (4) #5 x 20' construction joint F - (4) #5 x 20' construction joint
Lap splice = 2'-4.00" lap splice = 2'-4.00" lap splice = 2'-4.00" lap splice = 2'-4.00" lap splice = 2'-4.00"

construction joint Typical temp. bar - (62) construction joint


S - (4) #5 x 5'-5" K - (4) #5 x 5'-5" C - (4) #5 x 5'-5"
S - (4) #5 x 5'-5" #5 x 3'-8" AT 12" G - (4) #5 x 15'-4" A - (4) #5 x 20'

Lap splice = 2'-4.00"


T - (8) #5 x 21'-2" L - (4) #5 x 21'-2"

Typical temp. bar - (60)


D - (4) #5 x 21'-3"
Typical temp. bar - (44) #5 x 3'-8" AT 12"
#5 x 3'-8" AT 12" M - (4) #5 x 10'-4"

E - (4) #5 x 20'-10"

Lap splice = 2'-4.00"

Lap splice = 2'-4.00"


N - (4) #5 x 9'-7"
Typical temp. bar - (62)
construction joint #5 x 3'-8" AT 12"
S - (4) #5 x 5'-5" S - (4) #5 x 5'-5" J - (4) #5 x 14'-8 1/4 " I - (4) #5 x 20' C - (4) #5 x 5'-5" B - (4) #5 x 9'-8"
lap splice = 2'-4.00" construction joint lap splice = 2'-4.00"
K - (8) #5 x 5'-5"
construction joint

R - (4) #5 x 12'-11" S - (4) #5 x 5'-5" K - (8) #5 x 5'-5" Lap splice = 2'-4.00" Lap splice = 2'-4.00" Lap splice = 2'-4.00"

Q - (4) #5 x 20' construction joint F - (4) #5 x 20' construction joint


G - (4) #5 x 15'-4"
construction joint

Lap splice = 2'-4.00"


H - (4) #5 x 5'-5"
Typical temp. bar - (68)
U - (8) #5 x 16'-7" #5 x 3'-8" AT 12"
O - (8) #5 x 13'-11"
Typical temp. bar - (47)
#5 x 3'-8" AT 12" P - (4) #5 x 20'-10"
LEGEND:
V - (8) #5 x 20'-10"
1ST POUR
2nd POUR
Typical temp. bar - (74)
#5 x 3'-8" AT 12" 3rd POUR
4th POUR

LAYOUT OF REBAR ON FOOTING 5th POUR


6th POUR
7th POUR

NAVAID BUILDING

Layout of Rebar on footing


S-9 S-7
S-3

S-1

S-10
AREA 2 AREA 1
S-4

S-8 S-6 S-5 S-2

LEGEND:
AREA 1
AREA 2

CONSTRUCTION JOINT ON PRESSURE SLAB

NAVAID BUILDING

Construction Joint on Pressure Slab


S-9 S-7
S-3 (6) #4 x 20' AT 16"
(6) #4 x 24'-7" AT 16"

(20) #4 x 15' AT 16"

S-1

(7) #4 x 25' AT 16"

S-10 (20) #4 x 20' AT 16"

(20) #4 x 15'-11" AT 16"

S-4
(11) #4 x 6' AT 16"
(8) #4 x 7' AT 16" (8) #4 x 18'-4" AT 16"

(15) #4 x 18' AT 16"

S-8 S-6 S-5 S-2

(7) #4 x 20' AT 16"


(7) #4 x 14'-4" AT 16"
(7) #4 x 10' AT 16"

(12) #4 x 14'-4" AT 16"

(14) #4 x 21'-8" AT 16"

Rebar cuttinglist along longitudinal direction

(15) #4 x 6'-8" AT 16"


S-9 S-7
S-3

(7) #4 x 15' AT 16"

(14) #4 x 24' AT 16"


S-1
(13) #4 x 24' AT 16"

(28) #4 x 24' AT 16"

(15) #4 x 17'-6" AT 16"


S-10
(7) #4 x 12'-10" AT 16"

S-4

(7) #4 x 9'-4" AT 16"

(23) #4 x 7'-0" AT 16"


(12) #4 x 7' AT 16"

S-8 S-6 S-5 S-2

(12) #4 x 13'-8" AT 16"


(18) #4 x 16'-4" AT 16"

NAVAID BUILDING

Rebar Cutting list on Pressure Slab

Rebar cuttinglist along transverse direction


S-9 S-7
S-3
(5) #4 x 22'-6" AT 12"

(6) #4 x 14'-7" AT 12"

S-1(9) #4 x 10' AT 12"


(15) #4 x 5'-5" AT 12" (23) #4 x 5'-2" AT 12" (2) # 4 x 4'
Corner bar
S-10

S-4

(10) #4 x 9'-6" AT 12"


(11) #4 x 2' AT 16"

S-8 S-6 S-5 S-2


(5) #4 x 5'-11" AT 12"

(64) #4 x 2' AT 16" (26) #4 x 2' AT 16" (48) #4 x 2' AT 16"

(6) #4 x 4'-10" AT 12"

(48) #4 x 2' AT 16"

Rebar cuttinglist of concrete pad

NAVAID BUILDING

Rebar Cuttinglist of Pressure Slab


2'-8.00"

29'-0.91" 30'-0.05" 30'-7.08" 1'-8.00"


18'-11.04"

24'-4.00"
21'-2.56"
21'
2'-8.96"

10'-8.00" 17'-8.85" 13'-4.00" 12'-4.00" 11'-4.00" 15'-1.00" 1'-7.00"


2'-11.13" 2'-8.00"
LEGEND:

11'-7.04"
15'-0.04" 1st POUR
2nd POUR
3rd POUR
4th POUR
14'-8.00"
5th POUR
22'-0.04"
6th POUR
7th POUR

CONSTRUCTION JOINT ON RC WALL

NAVAID BUILDING

Construction joint on RC Wall


NAVAID BUILDING

Rebar Cuttinglist of RC Wall


LOCATOR PLAN

BEAM BOTTOM
BEAM BOTTOM
(4) #4 x 20'-4" AT 8"
(2) #4 x 20'-4" for door opening (4) #4 x 3'-10" AT 8"

(9) #4 x 3'-5" AT 8"


(7) #4 x 3'-10" for louver opening

(7) #4 x 10' AT 8"


(12) #4 x 10' AT 8"

(13) #4 x 9'-11" AT 8"

Each corner
(13) #4 x 5'-11" AT 8"

(2) # 4 x 4' Diag at

(5) #4 x 9'-1" for footer


(2) #5 x 14'-8" for header
(7) #4 x 3'-10" for louver opening (7) #4 x 20'-4" for louver opening

(16) #4 x 20'-4" AT 8"


(16) #4 x 3'-10" AT 8"

Each
corner
Diag at
(2) # 4 x 4'
(4) #4 x 12'-8" AT 8"
(4) #4 x 3'-10" AT 8" (4) #4 x 4'-6" AT 8"
(7) #4 x 20' AT 8"
(12) #4 x 20' AT 8"

(9) #4 x 18'-7" AT 8"

(2) #4 x 3'-9" for footer


(2) #5 x 8' for header
(4) #4 x 3'-10" for louver opening (4) #4 x 20'-4" for louver opening

(14) #4 x 20'-4" AT 8"


(14) #4 x 3'-10" AT 8"

(11) #4 x 20'-4" AT 8"


(11) #4 x 3'-10" AT 8"
(13) #4 x 8'-1" AT 8"

(2) #5 x 20'-6" for door jamb


(2) #5 x 4'-4" for door jamb
(9) #4 x 13'-8" AT 8"

(6) #4 x 13'-8" AT 8"

(14) #4 x 8'-5" AT 8"


(14) #4 x 5'-3" AT 8"
Each corner
(2) # 4 x 4' Diag at
(2) #5 x 14'-8" for header
Each corner

(2) #5 x 4'-4" for door jamb (2) #5 x 20'-6" for door jamb
(2) # 4 x 4' Diag at

(30) #4 x 20'-4" AT 8"


(9) #4 x 20' AT 8"

(30) #4 x 3'-10" AT 8"


(6) #4 x 20' AT 8"
(13) #4 x 15'-2" AT 8"

(2) #5 x 20'-6" for door jamb


Elevation Showing Vertical bars

(2)#5 x 4'-4" for door jamb (7) #4 x 20'-4" AT 8"


(7) #4 x 3'-10" AT 8"
Elevation Showing Horizontal bars
(13) #4 x 5'-11" AT 8"

Elevation Showing Miscellaneous bars

(14) #4 x 8'-5" AT 8"


(6) #4 x 14'-10" AT 8"
(9) #4 x 14'-10" AT 8"

Each corner

(14) #4 x 5'-3" AT 8"


(2) # 4 x 4' Diag at

(2) #5 x 20'-6" for door jamb (5) #4 x 20'-4" AT 8"


(2)#5 x 4'-4" for door jamb (5) #4 x 3'-10" AT 8"
(9) #4 x 6'-4" AT 8"

(5) #4 x 20'-4" AT 8"


(6) #4 x 6'-4" AT 8"

(2) #5 x 11'-8" for header (2) #5 x 5'-4" for header

(5) #4 x 3'-10" AT 8"


(2)#5 x 4'-4" for door jamb (2) #5 x 20'-6" for door jamb
(13) #4 x 5'-4" AT 8"

(14) #4 x 8'-5" AT 8"


Each corner

(14) #4 x 5'-3" AT 8"


(2) # 4 x 4' Diag at
(9) #4 x 14'-11" AT 8"

(6) #4 x 14'-11" AT 8"

(2) #5 x 14'-8" for header

(5) #4 x 20'-4" AT 8"


(5) #4 x 3'-10" AT 8"
(2)#5 x 4'-4" for door jamb (2) #5 x 20'-6" for door jamb
(3) #4 x 20'-4" AT 8"
(3) #4 x 3'-10" AT 8"
(28) #4 x 4'-8" AT 8"

(13) #4 x 2'-10" AT 8"


LOCATOR PLAN (2)#4 x 6'-5" (2)#4 x 6'-5"
4-(1)#4 x 6'-5", typ. column

(15) #4 x 3'-10" AT 8"


(2) #4 x 6' AT 8"

(2) #4 x 6' AT 8"

(8) #4 x 9'-11" AT 8"


(8) #4 x 9'-11" AT 8"
(5)#4 x 6'-5" (5)#4 x 6'-5"

(2) #4 x 4'-11" AT 8"

(2) #4 x 4'-11" AT 8"


(15) #4 x 3'-10" AT 8"
(8) #4 x 3'-10" AT 8"

(8) #4 x 3'-10" AT 8"


(5)#4 x 8' (5)#4 x 8'

(1)#4 x 8', typ. column


(2)#4 x 8' (2)#4 x 8'

Elevation Showing Vertical bars

(2) #4 x 5' (2) #4 x 5'


(9) #4 x 24'-6" AT 8" (9) ties #4 x 2'-2" (9) ties #4 x 2'-2"

(9) ties #4 x 1'-5" (9) ties #4 x 1'-5"

(1) #4 x 6'-4" AT 8" (1) #4 x 8'-10" AT 8" (1) #4 x 6'-4" AT 8"

(5) #4 x 24'-6" AT 8"


(5) #4 x 17'-2" AT 8"

Elevation Showing Horizontal bars

(16) #4 x 4'
Diag bar, (2)
each corner

Elevation Showing Miscellaneous bars

NAVAID BUILDING

Rebar Cuttinglist of RC Wall


(12) #4 x 7'-1" AT 8"
(46) #4 x 19' AT 8"

(48) #4 x 19' AT 8"

(29) #4 x 19' AT 8"


(3) #4 x 19' AT 8"

(6) #4 x 19' AT 8"


LOCATOR PLAN

(12) #4 x 8'-5" AT 8"


(46) #4 x 3'-10" AT 8"

(48) #4 x 3'-10" AT 8"

(29) #4 x 3'-10" AT 8"


(3) #4 x 3'-10" AT 8"

(6) #4 x 3'-10" AT 8"


Elevation Showing Vertical bars

(10) #4 x 20' AT 8"


(10) #4 x 12'-2" AT 8"

(29) #4 x 5'-3" AT 8" (29) #4 x 14'-3" AT 8" (29) #4 x 13'-8" AT 8"


(29) #4 x 20' AT 8" (29) #4 x 20' AT 8"

(8) #4 x 13'-8" AT 8" (8) #4 x 4'-8" AT 8"

(11) #4 x 20' AT 8"


(11) #4 x 12'-2" AT 8"

Elevation Showing Horizontal bars

(6) #4 x 19' for louver opening

(6) #4 x 19' for louver opening


(2) #5 x 14' for header

(2) # 4 x 4' Diag at


Each corner

(6) #4 x 3'-10" for louver opening

(6) #4 x 3'-10" for louver opening


(4) #4 x 9' for footer

NAVAID BUILDING

Rebar Cuttinglist of RC Wall Elevation Showing Miscellaneous bars


(10) #4 x 8'-1" AT 8"
(12) #4 x 7'-7" AT 8"
(5) #4 x 19'-3" AT 8"

(8) #4 x 19'-9" AT 8"

(4) #4 x 20'-2" AT 8"

(25) #4 x 9'-11" AT 8"


LOCATOR PLAN

(12) #4 x 8'-5" AT 8"


(5) #4 x 3'-10" AT 8"

(8) #4 x 3'-10" AT 8"

(4) #4 x 3'-10" AT 8"


(10) #4 x 5'-3" AT 8"

(25) #4 x 3'-10" AT 8"


Elevation Showing Vertical bars

(10) #4 x 5'-9" AT 8" (13) #4 x 5'-8" AT 8"

(10) #4 x 19'-1" AT 8"

(8) #4 x 3'-8" AT 8" (8) #4 x 3'-11" AT 8"

(12) #4 x 3'-7" AT 8"


(15) #4 x 17'-3" AT 8"
(5) #4 x 12'-2" AT 8"

(6) #4 x 19'-1" AT 8"


(11) #4 x 5'-9" AT 8" (6) #4 x 5'-8" AT 8"

Elevation Showing Horizontal bars

(2) #5 x 20'-2" for door jamb


(6) #4 x 19'-3" for louver opening

(6) #4 x 19'-8" for louver opening

(2) #5 x 19'-8" for door jamb


(2) #5 x 9'-8" for header
(2) #5 x 11'-1" for header

(2) # 4 x 4'
(2) # 4 x 4' Diag at
Diag at
Each corner
Each
corner
(6) #4 x 3'-10" for louver opening

(4) #4 x 9' for footer

(2) #5 x 4'-4" for door jamb


(6) #4 x 4'-4" for louver opening

(2) #5 x 4'-4" for door jamb

NAVAID BUILDING

Rebar Cuttinglist of RC Wall Elevation Showing Miscellaneous bars


LOCATOR PLAN

26-(1)#4 x 6'-5", 2-(2)#4 x 6'-5"

(19) #4 x 19'-3" AT 8"


typ. column

(19) #4 x 20'-2" AT 8"


both adjacent
wall

(19) #4 x 3'-10" AT 8"

(19) #4 x 3'-10" AT 8"


26-(1)#4 x 8', 2-(2)#4 x 8'
typ. column both adjacent
wall

Elevation Showing Vertical bars

(9)#4 x 1'-5" ties (28) #4 x 20' AT 8"

(28) #4 x 8'-8" AT 8"

(2) #4 x 14'-7"
(11) #4 x 3' AT 8"

(5) #4 x 14'-7" AT 8"

Elevation Showing Horizontal bars

NAVAID BUILDING

Rebar Cuttinglist of RC Wall


NAVAID BUILDING

Rebar Cutting list of RC Wall


LOCATOR PLAN

(2) #5 x 9'-11" for door jamb


(11) #4 x 3' AT 8"

(2) #5 x 3'-10" for door jamb (3) #4 x 9'-11" AT 8"


(3) #4 x 3'-10" AT 8"

(2) #5 x 9'-11" for door jamb (6) #4 x 5' AT 8"

(2) #5 x 3'-10" for door jamb

(16) #4 x 9'-11" AT 8"


(16) #4 x 3'-10" AT 8"
(6) #4 x 17'-4"AT 8"
(11) #4 x 9'-9" AT 8"
Elevation Showing Vertical bars

Elevation Showing Horizontal bars

Elevation Showing Miscellaneous bars


(5) #4 x 2'-3" AT 8"

(5) #4 x 3' AT 8"


(21) #4 x 19'-3" AT 8"

(23) #4 x 19'-3" AT 8"


(5) #4 x 13'-8" AT 8"

(5) #4 x 12'-8" AT 8"


LOCATOR PLAN

(21) #4 x 3'-10" AT 8"

(23) #4 x 3'-10" AT 8"


(5) #4 x 3'-10" AT 8"

(5) #4 x 3'-10" AT 8"


Elevation Showing Vertical bars Elevation Showing Vertical bars

(6) #4 x 14'-10" AT 8"


(6) #4 x 14'-9" AT 8"

(11) #4 x 20'-2" AT 8"

staggered
(11) #4 x 20'-2" AT 8"
(12) #4 x 20'-8" AT 8"

staggered
(12) #4 x 20'-8" AT 8"

Elevation Showing Horizontal bars Elevation Showing Horizontal bars

(2) #5 x 6'-7" for header

(2) #5 x 6'-7" for header

(3) #4 x 4' for footer (2) # 4 x 4'


Diag at
Each
(2) # 4 x 4' (3) #4 x 4' for footer
(6) #4 x 19'-6" for louver opening

corner

(6) #4 x 19'-3" for louver opening


Diag at
Each
corner
(6) #4 x 3'-10" for louver opening

(6) #4 x 3'-10" for louver opening


NAVAID BUILDING

Elevation Showing Miscellaneous bars Elevation Showing Miscellaneous bars


Rebar Cutting list of RC Wall
(5) #4 x 1'-7" AT 8"
(1) #4 x 1'-4" AT 8"

(4) #4 x 1'-2" AT 8"

(4) #4 x 1'-9" AT 8"


(2) #4 x 7'-11" AT 8"

(9) #4 x 8'-5" AT 8"

(5) #4 x 3'-5" AT 8"


(4) #4 x 3' AT 8"
(11) #4 x 18'-10" AT 8"
(11) #4 x 19'-9" AT 8"

(15) #4 x 18'-7" AT 8"


(1) #4 x 15'-8" AT 8"

(2) #4 x 15'-8" AT 8"


(2) #4 x 14'-3" AT 8"

(2) #4 x 19'-1" AT 8"


LOCATOR PLAN

(8) #4 x 6'-9" AT 8"


(11) #4 x 3'-10" AT 8"

(15) #4 x 3'-10" AT 8"

(2) #4 x 3'-10" AT 8"

(5) #4 x 5'-3" AT 8"

(8) #4 x 3'-10" AT 8"


(5) #4 x 5'-3" AT 8"
(15) #4 x 3'-10" AT 8"
Elevation Showing Vertical bars Elevation Showing Vertical bars

(2) #4 x 3'-10" AT 8" (4) #4 x 2'-3" AT 8"

(5) #4 x 8'-9" AT 8" (5) #4 x 5' -6" AT 8"

(2) #4 x 8'-2" AT 8"


(28) #4 x 5' AT 8"
(25) #4 x 4'-5" AT 8" (6) #4 x 20' -8" AT 8"
(14) #4 x 9'-8" AT 8"
(18) #4 x 5' AT 8"
staggered (25) #4 x 8' -6" AT 8"
(14) #4 x 9'-8" AT 8"
(11) #4 x 8'-1" AT 8"

7'-2.00"
(11) #4 x 10" AT 8"

(6) #4 x 4'-1" AT 8"

(6) #4 x 20' -8" AT 8"

Elevation Showing Horizontal bars Elevation Showing Horizontal bars


(2) #5 x 8'-11" for header (2) #5 x 6'-1" for header
(5) #4 x 20' for all
diagonal bar of blackouts
Note: Note:
(2)#4 x 4' diag at each corner, (2)#4 x 4' diag at each corner,
(8) #4 x 18'-11" for louver openings

where extension is not where extension is not


possible. extend bars as fas possible. extend bars as fas
as possible and hook 180° as possible and hook 180°
(3) #4 x 3'-11" for footer
(3) #4 x 4'-6" for footer
(2) #5 x 15'-8" for header

(10) #5 x 19'-1" for openings


(8) #4 x 3'-10" for louver openings

(3) #4 x 4'-6" for footer

(10) #5 x 4'-4" for opening


NAVAID BUILDING

Rebar Cuttinglist of RC Wall


Elevation Showing Miscellaneous bars Elevation Showing Miscellaneous bars
(6) #4 x 8'-1" AT 8"
(2) #4 x 12'-1" AT 8"

(14) #4 x 19'-4" AT 8"


(12) #4 x 18'-10" AT 8"
LOCATOR PLAN

(14) #4 x 3'-10" AT 8"


(2) #4 x 7'-1" AT 8"

(12) #4 x 3'-10" AT 8"

(6) #4 x 5'-3" AT 8"


Elevation Showing Vertical bars

(28) #4 x 4'-1" AT 8"

(28) #4 x 4'-1" AT 8" (11) #4 x 21' AT 8"

(10) #4 x 8' -9" AT 8" (11) #4 x 8' -5" AT 8"

(1) #4 x 5' -9" AT 8"

(6) #4 x 21' AT 8"

Elevation Showing Horizontal bars

(2) #5 x 9'-4" for header

(2) # 4 x 4'
(2) #5 x 19' AT 8"

(2) #5 x 19' AT 8"


Diag at
Each
corner

(2) # 4 x 4'
Diag at
Each
corner
(2) #5 x 4'-4" AT 8"

(2) #5 x 4'-4" AT 8"

NAVAID BUILDING

Rebar Cuttinglist of RC Wall Elevation Showing Miscellaneous bars


99'-4.00"
30'-4.00" 36'-5.34" 32'-6.66"

AREA 3 AREA 2 AREA 1

32'-4.04"
4'
4'

LEGEND:
CONSTRUCTION JOINT ROOF SLAB AND BEAM AREA 1
AREA 2
AREA 3
EXTENDED WORKING AREA

NAVAID BUILDING

Construction Joint on Roof Slab


(54) #5 x 8' AT 6" (74) #5 x 8' AT 6" (59) #5 x 8' AT 6" (5) #5 x 10' AT 6" OC
(5) #5 x 10' AT 6" OC (54) #5 x 32'-8" AT 6" BOT REINF (74) #5 x 32'-8" AT 6" BOT REINF (59) #5 x 32'-8" AT 6" BOT REINF ADDITIONAL TOP REINF
ADDITIONAL TOP REINF TOP REINF TOP REINF TOP REINF

(54) #5 x 23'-9" AT 6" (74) #5 x 23'-9" AT 6" (59) #5 x 23'-9" AT 6"


BOT REINF BOT REINF BOT REINF

26'-4.00"

(54) #5 x 8' AT 6" (74) #5 x 8' AT 6" (59) #5 x 8' AT 6"


BOT REINF BOT REINF BOT REINF

(5) #5 x 10' AT 6" OC


(5) #5 x 10' AT 6" OC ADDITIONAL TOP REINF
ADDITIONAL TOP REINF
Rebar cuttinglist along transverse direction

(65) #5 x 8' AT 6" (65) #5 x 14'-5" AT 6"


(65) #5 x 26' AT 6" (65) #5 x 13'-8" AT 6" (65) #5 x 30' AT 6"
TOP REINF TOP REINF (65) #5 x 20' AT 6" (65) #5 x 8' AT 6"
TOP REINF TOP REINF TOP REINF
TOP REINF TOP REINF

(65) #5 x 8' AT 6" (65) #5 x 12'-11" AT 6"


(65) #5 x 26' AT 6" (65) #5 x 11'-2" AT 6" (65) #5 x 30' AT 6" (65) #5 x 20' AT 6" (8) #5 x 20' AT 6"
BOT REINF BOT REINF
BOT REINF BOT REINF BOT REINF BOT REINF BOT REINF

NAVAID BUILDING

Rebar Cutting list on Roof Slab Rebar cuttinglist along longitudinal direction
6-1/4" 6-1/4" 6-1/4"

11"

11"

11"
(46) #4 x 3'-3" AT 8" (56) #4 x 3'-3" AT 8" (44) #4 x 3'-3" AT 8"

(3) #5 x 27' TOP REINF (3) #5 x 22'-8" TOP REINF (3) #5 x 20' TOP REINF (3) #5 x 32'-4" TOP REINF

(2) #4 x 21'-2" WEB BAR (2) #4 x 30'-9" WEB BAR


(2) #4 x 26'-2" WEB BAR (2) #4 x 20' WEB BAR

(3) #5 x 25'-8" BOT REINF


(3) #5 x 21'-2" BOT REINF (3) #5 x 31'-7" BOT REINF (3) #5 x 25'-8" TOP REINF
(3) #5 x 27' BOT REINF (3) #5 x 20' BOT REINF
(3) #5 x 25'-8" TOP REINF (3) #5 x 25'-8" BOT REINF

6-1/4"
6-1/4"

11"
11"

(38) #4 x 3'-3" AT 8"


(38) #4 x 3'-3" AT 8"

(3) #5 x 24' WEB BAR (3) #5 x 24' WEB BAR

(3) #5 x 27' TOP REINF (3) #5 x 22'-8" TOP REINF (3) #5 x 20' TOP REINF (3) #5 x 32'-4" TOP REINF

(2) #4 x 21'-2" WEB BAR (2) #4 x 30'-9" WEB BAR


(2) #4 x 26'-2" WEB BAR (2) #4 x 20' WEB BAR

(3) #5 x 21'-2" BOT REINF (3) #5 x 31'-7" BOT REINF


(3) #5 x 27' BOT REINF (3) #5 x 20' BOT REINF
6-1/4" 6-1/4" 6-1/4"
1'-10"

1'-10"

1'-10"
(46) #4 x 5'-1" AT 8" (56) #4 x 5'-1" AT 8" (44) #4 x 5'-1" AT 8"

NAVAID BUILDING Rebar cuttinglist of Roof beams

Rebar Cuttinglist of Roof beamsl


401 E. Main Street 2885 Pa’a Street, Unit #206
Montrose, CO 81401 Honolulu, HI 96819
(970) 497-8200 Office (808) 836-9650 Office
(970) 497-8201 Fax

Repair Bucholz Army Airfield (BAAF)


U.S. Army Kwajalein Atoll
Republic of the Marshall Islands

Section 03 31 29
Marine Concrete

SD-03 Product Data


2.8.1 Reinforcing Bars
CONTROLLED UNCLASSIFIED INFORMATION
REPAIR BUCHOLZ ARMY AIRFIELD (BAAF), KWAJALEIN ISLAND KWAJBAAF

environment shall be air entrained and shall conform to the air limits
specified in ACI 301. Variations outside the limits specified shall not
be reason to reject the concrete in locations not subject to
freeze-thaw conditions.

g. Slump. The concrete mixture shall be proportioned to have, at the point


of deposit, a maximum slump of 4 inches as determined by ASTM C143/C143M.
Where an ASTM C494/C494M, Type F or G admixture is used, the slump
after the addition of the admixture shall be no less than 6 inches nor
greater than 8 inches. Slump tolerances shall comply with the
requirements of ACI 117.

h. Chloride Ion Penetration. To ensure the durability of concrete in a


marine environment, concrete shall be proportioned to provide a rapid
indication of its resistance to the penetration of chloride ions, per
ASTM C1202, of below 3,000 coulombs for concrete specimens tested at 56
days.

2.7 MATERIALS FOR FORMS

Provide wood, plywood, or steel. Use plywood or steel forms where a smooth
form finish is required. Lumber shall be square edged or tongue-and-groove
boards, free of raised grain, knotholes, or other surface defects.

Plywood: APA PS 1, B-B concrete form panels or better. Steel form


surfaces shall not contain irregularities, dents, or sags.

2.7.1 Form Ties and Form-Facing Material

a. Provide a form tie system that does not leave mild steel after
break-off or removal any closer than 2 inches from the exposed
surface. Do not use wire alone. Form ties and accessories shall not
reduce the effective cover of the reinforcement.

b. Form-facing material shall be structural plywood or other material that


can absorb air trapped in pockets between the form and the concrete and
some of the high water-cementitious materials ratio surface paste.
Maximum use is three times. Provide forms with a form treatment to
prevent bond of the concrete to the forms.

c. As an alternate to using an absorptive wood form contact face as a form


liner, use a Controlled Permeability Formliner in strict accordance
with the manufacturer's recommendations.

2.8 REINFORCEMENT

2.8.1 Reinforcing Bars

ACI 301 unless otherwise specified and shall meet the design yield strength
and ductility requirements. Deformed reinforcing bars meeting the
requirements of ASTM A615/A615M with the bars marked A, Grade 60 and
galvanized in accordance with ASTM A767/A767M, class II coating.

2.9 MATERIALS FOR CURING CONCRETE

2.9.1 Impervious Sheeting

ASTM C171; waterproof paper, clear or white polyethylene sheeting, or


polyethylene-coated burlap.

SECTION 03 31 29 Page 24