Professional Documents
Culture Documents
03 31 29 Marine Concrete - Reinforcing Rebar
03 31 29 Marine Concrete - Reinforcing Rebar
Section 03 31 29
Marine Concrete
Section 03 31 29
Marine Concrete
17'-8.00"
21'-2.00"
21'-2.00"
26'-2.00"
14'-8.00"
6'-7.96"
9'
LEGEND:
10'-10.04"
13'-6.04"
1st POUR
2nd POUR
3rd POUR
4th POUR
5th POUR
16'-6.00"
6th POUR
23'-10.04"
7th POUR
NAVAID BUILDING
E - (4) #5 x 20'-10"
R - (4) #5 x 12'-11" S - (4) #5 x 5'-5" K - (8) #5 x 5'-5" Lap splice = 2'-4.00" Lap splice = 2'-4.00" Lap splice = 2'-4.00"
NAVAID BUILDING
S-1
S-10
AREA 2 AREA 1
S-4
LEGEND:
AREA 1
AREA 2
NAVAID BUILDING
S-1
S-4
(11) #4 x 6' AT 16"
(8) #4 x 7' AT 16" (8) #4 x 18'-4" AT 16"
S-4
NAVAID BUILDING
S-4
NAVAID BUILDING
24'-4.00"
21'-2.56"
21'
2'-8.96"
11'-7.04"
15'-0.04" 1st POUR
2nd POUR
3rd POUR
4th POUR
14'-8.00"
5th POUR
22'-0.04"
6th POUR
7th POUR
NAVAID BUILDING
BEAM BOTTOM
BEAM BOTTOM
(4) #4 x 20'-4" AT 8"
(2) #4 x 20'-4" for door opening (4) #4 x 3'-10" AT 8"
Each corner
(13) #4 x 5'-11" AT 8"
Each
corner
Diag at
(2) # 4 x 4'
(4) #4 x 12'-8" AT 8"
(4) #4 x 3'-10" AT 8" (4) #4 x 4'-6" AT 8"
(7) #4 x 20' AT 8"
(12) #4 x 20' AT 8"
(2) #5 x 4'-4" for door jamb (2) #5 x 20'-6" for door jamb
(2) # 4 x 4' Diag at
Each corner
(16) #4 x 4'
Diag bar, (2)
each corner
NAVAID BUILDING
NAVAID BUILDING
(2) # 4 x 4'
(2) # 4 x 4' Diag at
Diag at
Each corner
Each
corner
(6) #4 x 3'-10" for louver opening
NAVAID BUILDING
(2) #4 x 14'-7"
(11) #4 x 3' AT 8"
NAVAID BUILDING
staggered
(11) #4 x 20'-2" AT 8"
(12) #4 x 20'-8" AT 8"
staggered
(12) #4 x 20'-8" AT 8"
corner
7'-2.00"
(11) #4 x 10" AT 8"
(2) # 4 x 4'
(2) #5 x 19' AT 8"
(2) # 4 x 4'
Diag at
Each
corner
(2) #5 x 4'-4" AT 8"
NAVAID BUILDING
32'-4.04"
4'
4'
LEGEND:
CONSTRUCTION JOINT ROOF SLAB AND BEAM AREA 1
AREA 2
AREA 3
EXTENDED WORKING AREA
NAVAID BUILDING
26'-4.00"
NAVAID BUILDING
Rebar Cutting list on Roof Slab Rebar cuttinglist along longitudinal direction
6-1/4" 6-1/4" 6-1/4"
11"
11"
11"
(46) #4 x 3'-3" AT 8" (56) #4 x 3'-3" AT 8" (44) #4 x 3'-3" AT 8"
(3) #5 x 27' TOP REINF (3) #5 x 22'-8" TOP REINF (3) #5 x 20' TOP REINF (3) #5 x 32'-4" TOP REINF
6-1/4"
6-1/4"
11"
11"
(3) #5 x 27' TOP REINF (3) #5 x 22'-8" TOP REINF (3) #5 x 20' TOP REINF (3) #5 x 32'-4" TOP REINF
1'-10"
1'-10"
(46) #4 x 5'-1" AT 8" (56) #4 x 5'-1" AT 8" (44) #4 x 5'-1" AT 8"
Section 03 31 29
Marine Concrete
environment shall be air entrained and shall conform to the air limits
specified in ACI 301. Variations outside the limits specified shall not
be reason to reject the concrete in locations not subject to
freeze-thaw conditions.
Provide wood, plywood, or steel. Use plywood or steel forms where a smooth
form finish is required. Lumber shall be square edged or tongue-and-groove
boards, free of raised grain, knotholes, or other surface defects.
a. Provide a form tie system that does not leave mild steel after
break-off or removal any closer than 2 inches from the exposed
surface. Do not use wire alone. Form ties and accessories shall not
reduce the effective cover of the reinforcement.
2.8 REINFORCEMENT
ACI 301 unless otherwise specified and shall meet the design yield strength
and ductility requirements. Deformed reinforcing bars meeting the
requirements of ASTM A615/A615M with the bars marked A, Grade 60 and
galvanized in accordance with ASTM A767/A767M, class II coating.
SECTION 03 31 29 Page 24