Project | EMC P176 (P150) Doc. tite: | Internal Commissioning — Power Drives Solutions WARTSILA Dos. no: | EMO424-ACP Rev 07 5.11 Flow measurement of Cooling Water After flushing and Power modules are installed, the flow shall be measured by using test, manometers at the measurement points at the Cooling water manifolds located under the VSD cabinets or other suitable equipment. Max water pressure is 4 bars. Minimum 2 bar differential pressure between the inlet and outlet manifolds is a demand to achieve required flow. A flow meter can be installed in the cooling water loop if desirable. Verify cooling water flow through Power drive by measuring differential pressure on manifolds or flowmeter. (Max pressure 4 bar. Minimum differential pressure 2 bar) Verify no indication of water leaks after minimum 1 hour of circulating through all modules. Verify cooling water temperature within range (max 38 deg C, minimum 22 deg C and higher than condensation level)