RE.S.F.NO.509/A1A1 1.00 m Rain water PLAN SHOWING THE PROPOSED CONSTRUCTION OF R.C.

C
20.50M Harvesting pit
B C ROOF STILT FLOOR, FIRST FLOOR AND SECOND FLOOR

2.36 M

2.36 M
1.83M ST DT 1.52M
17.08 M COMMERCIAL BUILDING FOR PURPOSE OF " SHOP BUILDING "

Car Parking
IN NATHAM RE.S.F.NO.509/A1A2, WARD.NO.16, AT VELLAKOVIL TO
6 5
Head Room
2.00 m ht Compound wall DHARAPURAM ROAD, VELLAKOVIL VILLAGE & MUNICIPALITY,

2.50 M
Parapet Wall arrangements

6.00m WIDE DRIVE WAY


7

RE.S.F.NO.509/A1A2
Weathering Coarse
4 KANGAYAM TALUK, TIRUPUR DISTRICT.

2.44
R.C.C Roof Slab in 1:2:4 mix

1.22

13.27 M
RE.S.F.NO.509/A1B

RE.S.F.NO.509/B1A
5.00 M

2.50 M
0.12
3.00 APPLICANT :
8 2.50 M

21.60M
Brick work in C.M 1:6 mix
Mr.M.ADHISHKRISHNA, S/o.Mr.A.S.N.MURUHESH.

3.05
5.00 M

23.80M
R.C.C Lintel cum sunshade

0.12
in 1:2:4 mix
Car Parking up
ONLINE APPLICATION No: SWP / BPA /004615/2022 ; DATE: 18.12.2022

6.00 M
10.73
9.51
AREA OF DETAILS IN SQ.M

3.05
3 467.00

E
PLR/FMB AREA

N
LIFT

SE
2.44M X 2.44M 1.50 1.50

0.12

1.82

S
As per Document 467.17

SW
N
W

W
Floor Finishing in CM
Super Imposed Plot area 465.95
3.05
Flooring concrete in 1:5:10 mix 1.89 M 7
Earth and sand filling 9 2 1.56M

1.50m WIDE DRIVE WAY


PROPOSED BUILDING FLOOR WISE BREAKUP DETAILS

Two Wheeler Parking


G L

6.20 M
R.C.C Column Footing in 1:2:4 mix FLOOR NAME NON FSI AREA COMMERCIAL

8.00 M
2.42

2.50 M

2.50 M
ELEVATION P.C.C in 1:5:10 mix
1
0.23 0.82
10 4
0.23 TOTAL TOTAL
1.52
5.00 M
1.80
5.00 M SITE PLAN BUILTUP PARKING DEDUCTION FSI AREA
A 8 AREA (Sq.mt)
Scale 1:100

1.00
10
SECTION ON - "AB" VELLAKO ENTRY / EX (Sq.mt)

1.00
9

1.00
VIL TOWN IT 1
1.80
20.70M 1.80 FLOOR-STILT 226.66 226.66 - -
ENTRY / EXIT
D
10.80M WID FLOOR-FIRST 226.66 - - 226.66
E VELLAK
OVIL TO DHARA
P URAM ROA FLOOR-SECOND 226.66 - - 226.66
D (SH - 197)
RE.S.F.No TOTAL 679.98 226.66 - 453.32
.508
TOTAL F.S.I AREA 453.32
DHARAPU
RAM FSI =
SITE EXTENT
= 467.00 = 0.973<2.00
17.08 17.08
0.23 0.15 0.23 0.23 0.15 0.23 OSR Fees Rs. 1,81,000/- Paid on 14.02.2023
17.08 14.95 14.95 17.08
1.52 1.52
PARKING DETAIL REQUIRED PROVIDED

0.23

0.23

0.23
W W W W W1 W W W W W1
W.C
D1 1.52Mx1.52M V
W.C
D1 1.52Mx1.52M V CAR PARKING 10 10
SOLAR SOLAR SOLAR SOLAR

W W
SYSTEM
1000 liters
SYSTEM
1000 liters
SYSTEM
1000 liters
SYSTEM
1000 liters TWO WHEELERS PARKING 10 10
W.C W.C
D1 1.52Mx1.52M V D1 1.52Mx1.52M V
A B COLOUR INDEX
W.C W.C
D1 1.52Mx1.52M D1 1.52Mx1.52M SOLAR SOLAR SOLAR SOLAR
V V
SYSTEM SYSTEM SYSTEM SYSTEM SITE BOUNDARY SCALE:
W 1000 liters 1000 liters 1000 liters 1000 liters
W
PARKING SHOP W.C
D1 1.52Mx1.52M V
SHOP W.C
D1 1.52Mx1.52M V
OPEN TERRACE PROPOSED BUILDING All Dimensions are in " Meters " PLAN :1:100
17.08M X 13.27M
13.27

13.27

13.27

13.27
14.95M X 12.81M 14.95M X 12.81M
12.81

12.81

12.81
3.00
D
EXISTING ROAD
SITE PLAN:1:100
1.50 1.50 1.50 1.50 SOLAR SOLAR 1.50 1.50
SYSTEM
1000 liters
SYSTEM
1000 liters
DRIVE WAY
W W
up up up up

D D D D
SOLAR SOLAR
BP / TCP [TD] No : 17 / 2023
LIFT LIFT LIFT LIFT SYSTEM SYSTEM
2.44M X 2.44M 1.50 1.50 2.44M X 2.44M 2.44M X 2.44M 2.44M X 2.44M
1000 liters 1000 liters
1.82

1.60

1.60

1.60
0.23

0.23

0.23
W W W W W W W W W W
SUPERVISOR - K.PADMA
STILT FLOOR PLAN FIRST FLOOR PLAN SECOND FLOOR PLAN TERRACE FLOOR PLAN SURVEYOR / AD MAN - B.JAYARANI

Vent pipe 16 mm c/c @ 6 Nos RAIN WATER HARVESTING SYSTEM


R.C.C coverslab
B.W in C.M 1:6 RAIN WATER HARVESTING TANK
G L
perforated pipe
GL6" GL Earth Filling
5'0" 4'0"
BUILDING
4.5"

2.44
6" SIDE ELEVATION
Outlet pipe
Inlet pipe 7'0" Baffle wall

RAIN WATER PIPE


PCC 1:5:10
1'0"
Brick bats (or) pebble stone.
FOUNDATION CONCRETE
IN C.C 1:4:8 MIX
SECTION OF S.P.T & D.T CONCRETE SLAB
SECTION [Not To Scale]
DRUM
SAND
Inlet chamber Outlet chamber SOLAR
PLAN BRICK BATS
9" CELL
SOLAR WATER HEATER PLAN
4'0" DETAILS [Not To Scale}
9" 12mm @6"c/c Both Way PLAN
FILTER BED
2'0" 2'6"
9" 9" 4.5"
5'6" 2'6" 2'0"
4.5" 9" 9" 10'0" FOUNDATION DETAILS 1.98x1.98x2.44m APPLICANT
PLAN OF S.P.T & D.T
SECTIONAL ELEVATION FOR SEWAGE/SULLAGE TREATEMENT PLANT
Rain Water Pipe
NOT TO SCALE: 5 115 thk. brick wall

Building Line
TOILET FLUSHING Perculation
Pit.
2
EXCESS WATER 2.50M COMPOUND WALL
TO GARDENING/DRAINAGE
3 INSIDE
7
4 G.L G.L
1
7 Slope 1 in 20 B.W in c.m 1:6 mix
RECIRCULATION LINE
9.00 M
5 to 7.5 c.m.
0.45 rounded size pebbles 2.00
R.R Work in c.m 1:6 mix
MAIN GATE 0.45
1. COLLECTION TANK 2.00m X 2.00m X 3.00m
2. AERATION TANK 1.25m X 1.25m X 3.00m G.L
Collection rain water from building 0.30 P.c.c 1:5:10 in foundation
3. SETTLING TANK 1.25m X 1.25m X 3.00m Sand filling in foundation
4. TREATED EFFLUENT 5.12m X 4.99m X 1.22m 0.46
GL GL
COLLECTION TANK 10.0m X 8.50m X 0.25m 0.61
FIRE ALARAM 0.15
5. ELEVATED TANK
SYSTEM Sand filling 0.15
8 6. SLUDGE DRYING BED 3' dia
6 7. COLLECTION PUMP
FIRE WATER PIPE
Fine pebble stone 0.46
DRY SLUDGE

10'
8. SLUDGE PUMP 0.61
TO DISPOSAL FIRE FIGHTING 9"tk. brick work

Signature Not Verified EQUPEMENTS

PLAN FOR RAIN


Course pebble
stone filling
0.76
SECTION

SULLAGE LINE DRINKING WATER LINE WATER COLLECTION TANK


Signed by: Assistant Director
Location:Tiruppur RAIN WATER LINE
SEWAGE LINE
SULLAGE TREATED WATER LINE
EXISTING DRAIN
4'-6"
SECTION ON RAIN
REGISTERED ENGINEER
Date:2023.02.28 13:13:34