Hoja de Especificaciones JW6H-NL

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

C LARK E

FIRE PUMP DRIVERS


MODELS
JW6H-NL30
JW6H-NL40
JW6H-NL50
JW6H-NL60

Non-listed NFPA Like - Heat Exchanger Engines


Gross Power BHP/kW
JW6H OPERATING SPEED
MODEL 1760 1800 2000 2100 2200 2350
291 292 299 302 302 302
NL30
217 218 223 225 225 225
319 320 327 330 330 330
NL40
238 239 244 246 246 246
330 335 361 374 378 385
NL50
246 250 269 279 282 287
396 396 408 412.5 406 396
NL60
295 297 304 308 303 295
*Power rating: a 10% deduction in power must be made to determine the maximum allowable pump load.

Engine Equipment
JW6H-NL50
Equipment Standard Optional OVERALL WIDTH
Air Cleaner Direct Mounted, Washable, Disposable, Drip proof, 29.5
Indoor Service Indoor Service
[749]
Outdoor Type
Alternator 12V-DC, 42 Amps; w/Belt 24V-DC, 40 Amps; w/Belt Equipment Standard Optional
Guard Guard Instrument English & Metric, Tachometer,
Exhaust Blankets* For Manifolds & Turbocharger Panel Hourmeter, Water Tempera-
ture, Oil Pressure & Two (2)
Coupling Falk Coupling, Engine Half
Voltmeters
UF30/38/40/48 - 1080T10;
UF58/58/60 - 1090T10 Junction Box Integral with Instrument Panel;
Drive Shaft & Guard, For DC Wiring Interconnec-
SC2130 Drive Shaft tion to Engine Controller
System Lube Oil Cooler Engine Water Cooled,
Plate Type
Exhaust Flex SS Flex, 150# Flange Lube Oil Filter Full Flow w/By-Pass Valve
Connection Lube Oil Pump Gear Driven, Gear Type
Flywheel S.A.E. #3 Manual Start On Instrument Panel
Housing Controls
Flywheel Power 11.5” S.A.E. Industrial Overspeed Electronic w/Reset & Test on
Take Off Flywheel Connection Instrument Panel
Control
Fuel Fire Resistant Flexible Raw Water Sole- Automatic from Engine Con-
Connections Supply & Return Lines troller & from Emergency
noid Operation
Local Control
Fuel Filter Primary & Secondary
w/priming pump Run-Stop On Instrument Panel w/Con-
Control trol Position Warning Light
Fuel Injection Bosch Direct Injection, Inline
System Run Solenoid 12V-DC Energized to Run 24V-DC Energized to Run
12V-DC Energized to Stop
Engine Heater* 230V-AC, 2500 Watt 24V-DC Energized to Stop
115V-AC, 2500 Watt Starters One (1) 12V-DC One (1) 24V-DC
Governor, Speed Constant Speed, Mechanical Throttle Control Adjustable Speed Control,
Tamper Proof
Heat Exchanger Tube & Shell Type, 60 PSI        
w/NPTF Connections Water Pump Gear Driven, Centrifugal Type
*Required to comply with NFPA-20
meets
NFPA-20
Requirements
C LARK E
FIRE PUMP DRIVERS
MODELS
JW6H-NL30
JW6H-NL40
JW6H-NL50
JW6H-NL60
Specifications
JW6H Models
Item
NL30 NL40 NL50 NL60
Number of Cylinders 6
Aspiration TA TRWA
Rotation* CounterClockwise (CCW)
Weight - kg (lb) 910 (2012) 906 (2003) 929 (2053)
Compression Ratio 16.5:1 15.7:1
Displacement - L (cu. in.) 8.1 (496)
Engine Type 4 Stroke Cycle - Inline Construction
Bore & Stroke - mm (in.) 116 mm x 127 mm (4.56 in. x 5.06 in.)
Installation Drawing D - 495
Wiring Diagram C07602
Engine Series John Deere 6081 Series
Abbreviations: CCW – CounterClockwise   TA – Turbocharged & Aftercooled TRWA - Turbocharged with Raw Water Aftercooling
*Rotation viewed from Flywheel CW Rotation is not available
Engine intended for indoor use or inside weatherproof enclosure only.


ENGINE RATINGS BASELINES
Engines are rated at standard SAE conditions of 7521 mm Hg barometer and 25˚C inlet air temperature [approximates 91.4 m above sea level] by the
testing laboratory (see SAE Standard J 1349).
A deduction of 3 percent from engine horsepower rating at standard SAE conditions shall be made for diesel engines for each 305 m altitude above
91.4 m.
A deduction of 1 percent from engine horsepower rating as corrected to standard SAE conditions shall be made for diesel engines for every 5.6˚C
above 25˚C ambient temperature.

GUARANTEED POWER AT ANY SPEED


Although BHP ratings are shown at specific speeds, Clarke engines can be applied at any intermediate
speed. To determine the intermediate certified power, make a linear interpolation from the Clarke FM-UL
power curve. Contact Clarke or your Pump OEM representative to obtain details.

CLARKE
www.clarkefire.com Fire Protection Products
CLARKE UK, Ltd. CLARKE Fire Protection Products, Inc.
Grange Works, Lomond Rd. 3133 E. Kemper Rd.
Coatbridge, ML5-2NN Cincinnati, Ohio 45241
United Kingdom United States of America
Tel +44-1236-429946   Fax +44-1236-427274 Tel +1-513-771-2200   Fax +1-513-771-0726