Code 6896-01 - Octa-Slide 2

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

DPD CHLORINE-BROMINE-pH TEST KIT

Code 6896-01 | Octa-Slide 2


QUANTITY CONTENTS CODE
100 DPD 1R Tablets 6999A-J
50 Phenol Red Tablets 6915A-H
3 Test Tubes, 2.5-5-10 mL, plastic w/caps 0106 *Reagent is a potential health
1 Chlorine/Bromine Octa-Slide 2 Bar 2085-01 hazard. READ SDS: lamotte.com
1 Phenol Red Octa-Slide 2 Bar, pH 6.8-8.2 3403-01 Emergency information:
Chem-Tel USA 1-800-255-3924
1 Octa-Slide 2 Viewer 1101 Int’l, call collect, 813-248-0585
To order individual reagents or test kit components, use the
specified code number.

Warning! This set contains chemicals that may be harmful if misused. Read cautions on individual containers carefully.
Not to be used by children except under adult supervision.

USE OF THE
OCTA-SLIDE 2 VIEWER

PROCEDURE
NOTE: The Chlorine/Bromine Octa-Slide 2 Bar supplied with this kit gives both chlorine and
bromine readings. The values for chlorine appear next to each color standard in black and
the values for bromine appear next to each color standard in blue.

FREE AVAILABLE CHLORINE


1. Insert the Chlorine/Bromine Octa-Slide 2 Bar (2085-01) into the Octa-Slide 2 Viewer
(1101).
2. Fill a test tube (0106) to the 5 mL line with sample water.
3. Add one DPD 1R Tablet (6999A). Cap and mix until the tablet disintegrates.
4. Immediately insert the test tube into the Octa-Slide 2 Viewer.
5. Hold the Viewer so that non-direct light enters through the back. Match the sample
color to a color standard. Record the Chlorine value (in black) from the Octa-Slide 2 Bar.
Record as ppm Chlorine.

Continued next page...


BROMINE
1. Insert the Chlorine/Bromine Octa-Slide 2 Bar (2085-01) into the Octa-Slide 2 Viewer
(1101).
2. Fill a test tube (0106) to the 5 mL line with sample water.
3. Add one DPD #1R Tablet (6999A). Cap and mix until the tablet disintegrates.
4. Immediately insert the test tube into the Octa-Slide 2 Viewer.
5. Hold the Viewer so that non-direct light enters through the back. Match the sample
color to a color standard. Record the Bromine value (in blue) from the Octa-Slide 2 Bar.
Record as ppm Bromine.

pH
1. Insert the Phenol Red Octa-Slide 2 Bar (3403-01) into the Octa-Slide 2 Viewer (1101).
2. Fill a test tube (0106) to the 10 mL line with sample water.
3. Add one Phenol Red Tablet (6915A). Cap and mix until the tablet disintegrates.
4. Insert the test tube into the Octa-Slide 2 Viewer.
5. Hold the Viewer so that non-direct light enters through the back. Match the sample
color to a color standard. Record as pH.

LAMOTTE COMPANY | 802 Washington Avenue | Chestertown, Maryland | 21620 USA


800.344.3100 | +1 410.778.3100 (Outside USA) | Fax 410.778.6394 | lamotte.com
©2022 LaMotte Company, All Rights Reserved 66896-01 02.21.2023

You might also like