WTA Cable

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Siechem WTA RoHS

Wires
Wires&&Cables
Cables

Application Product Construction Technical Data


ü Low-voltage Cable is desingned for used at nominal ü Conductor : Soft-annealed electrolytic copper ü Temperature Range :
Voltage of 60 V DC (60 V AC rms) or surface vehicles E- Cu ETP1 according to ASTM B3 conductor construction - 40°C to +85°C (3000 Hours)
electrical systems according to customer specifications ü Standard : SAE J1678
ü Insulation : PVC Ultra - Thin wall ü WTA : Ultra Thin wall PVC Insulation
accoriding to SAE J 1678 Ford WSBM1 L134 -A /
Chrysler MS 9532 / Lear UTMS 12501
2D View
Features
ü Flexible
ü Excellent resistance to oil and flame
ISO ISO IATF OHSAS
WTA 9001 14001 16949 18001

Conductor Construction Cable Max.


Part Insulation Current
Size Wall Thickness Overall Conductor Standard
Number Nominal No. of Diameter of Conductor Weight Carrying
Nom. Diameter Resistance Length*
Cross- Strands Single wire Diameter Capacity
Max.
Approx. at 200C
Section max. Max.
AWG mm2 nos. mm mm mm mm kg/km Ω/km Amps mtrs
A88283XX* 22 0.35 7 0.25 0.76 0.20 1.35 4 53.9 9 500
A88282XX 20 0.5 7 0.32 0.97 0.20 1.55 7 34.3 12 500
A88281XX 18 0.8 19 0.23 1.17 0.20 1.75 8 23.0 15 500
A88280XX 16 1.3 19 0.28 1.45 0.20 2.03 12 15.5 20 500
A88279XX 14 2 19 0.36 1.8 0.20 2.39 19 9.44 27 500
A88278XX 12 3 19 0.45 2.3 0.24 3.00 30 6.0 37 500

Note : XX* : Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11
Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21

ü Current Carrying capacity given is for the maximum conductor operating temperature of 850C and ambient air temperature of 400C.
ü * Other length as per Customer order.

Catalogue
No

A882

Siechem Wires & Cables Meet EU RoHS Directive


Lead Hg Cd Cr6+ PBB PBDE
Free Free Free Free Free Free

www.siechem.com
45
All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and
Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.