Download as pdf or txt
Download as pdf or txt
You are on page 1of 90

Project:

Project no:
Author:

Project data
Project name
Project number
Author
Description
Date 03-01-2024
Design code IS

Material
Steel E 250 (Fe 410 W) A, YST 275

1 / 90
Project:
Project no:
Author:

Project item CON1

Design
Name CON1
Description
Analysis Stress, strain/ simplified loading

Beams and columns


β – Direction γ - Pitch α - Rotation Offset ex Offset ey Offset ez
Name Cross-section Forces in
[°] [°] [°] [mm] [mm] [mm]
B1 1 - ISMB 600 0.0 0.0 0.0 0 0 0 Node
B2 1 - ISMB 600 180.0 0.0 0.0 0 0 0 Node

2 / 90
Project:
Project no:
Author:

3 / 90
Project:
Project no:
Author:

Cross-sections
Name Material
1 - ISMB 600 YST 275

Cross-sections
Name Material Drawing

1 - ISMB 600 YST 275

Bolts
Diameter fu Gross area
Name Bolt assembly
[mm] [MPa] [mm2]
M24 8.8 M24 8.8 24 830.0 452

4 / 90
Project:
Project no:
Author:

Load effects (equilibrium not required)


N Vy Vz Mx My Mz
Name Member
[kN] [kN] [kN] [kNm] [kNm] [kNm]
LE1 B1 150.0 0.0 -90.0 0.0 790.0 0.0

Check

Summary
Name Value Check status
Analysis 100.0% OK
Plates 4.2 < 5.0% OK
Bolts 84.7 < 100% OK
Buckling Not calculated

Plates
fyd Thickness σ εPl σcEd
Name Material Loads Check status
[MPa] [mm] [MPa] [%] [MPa]
B1-bfl 1 YST 275 250.0 20.3 LE1 251.1 0.5 31.6 OK
B1-tfl 1 YST 275 250.0 20.3 LE1 254.4 2.2 17.6 OK
B1-w 1 YST 275 250.0 12.0 LE1 253.3 1.6 7.6 OK
B2-bfl 1 YST 275 250.0 20.3 LE1 251.4 0.7 31.7 OK
B2-tfl 1 YST 275 250.0 20.3 LE1 258.5 4.2 20.4 OK
B2-w 1 YST 275 250.0 12.0 LE1 257.6 3.8 20.4 OK
SPL1a YST 275 250.0 16.0 LE1 250.5 0.3 20.5 OK
SPL1b YST 275 250.0 16.0 LE1 250.4 0.2 17.9 OK
SPL1c YST 275 250.0 16.0 LE1 250.3 0.2 17.9 OK
SPL2a YST 275 250.0 12.0 LE1 250.5 0.2 31.7 OK
SPL2b YST 275 250.0 16.0 LE1 250.3 0.1 24.8 OK
SPL2c YST 275 250.0 16.0 LE1 250.3 0.1 24.7 OK
SPL3a YST 275 250.0 16.0 LE1 199.6 0.0 7.9 OK
SPL3b YST 275 250.0 16.0 LE1 196.7 0.0 7.8 OK

5 / 90
Project:
Project no:
Author:

Overall check, LE1

Strain check, LE1

6 / 90
Project:
Project no:
Author:

Equivalent stress, LE1

7 / 90
Project:
Project no:
Author:

Bolts
Tb Vsb Vdpb Utt Uts Utts
Shape Item Loads Status
[kN] [kN] [kN] [%] [%] [%]
B1 LE1 5.1 97.4 322.5 2.4 71.9 51.8 OK
B2 LE1 1.7 96.7 217.6 0.8 82.7 68.3 OK
B3 LE1 24.5 92.5 217.6 11.6 78.6 63.1 OK
B4 LE1 5.1 97.4 322.5 2.4 71.9 51.8 OK
B5 LE1 1.7 96.7 217.6 0.8 82.7 68.3 OK
B6 LE1 24.5 92.5 217.6 11.6 78.6 63.1 OK
B7 LE1 4.8 97.7 322.5 2.3 72.2 52.2 OK
B8 LE1 2.5 97.8 217.6 1.2 83.4 69.5 OK
B9 LE1 24.9 91.4 217.6 11.8 77.6 61.6 OK
B10 LE1 4.7 97.7 322.5 2.3 72.2 52.2 OK
B11 LE1 2.5 97.8 217.6 1.2 83.4 69.5 OK
B12 LE1 24.9 91.4 217.6 11.8 77.6 61.6 OK
B13 LE1 27.9 93.6 217.6 13.2 84.3 72.8 OK
B14 LE1 3.4 91.0 217.6 1.6 82.9 68.7 OK
B15 LE1 5.4 92.2 128.6 2.6 70.6 49.9 OK
B16 LE1 27.9 93.6 217.6 13.2 84.3 72.8 OK
B17 LE1 3.4 91.0 217.6 1.6 82.9 68.7 OK
B18 LE1 5.4 92.2 128.6 2.5 70.6 49.9 OK
B19 LE1 27.6 94.6 217.6 13.1 84.7 73.5 OK
B20 LE1 3.2 91.2 217.6 1.5 83.1 69.1 OK
B21 LE1 5.3 91.1 128.6 2.5 70.4 49.6 OK
B22 LE1 27.6 94.6 217.6 13.1 84.7 73.5 OK
B23 LE1 3.2 91.2 217.6 1.5 83.1 69.1 OK
B24 LE1 5.3 91.1 128.6 2.5 70.4 49.6 OK
B25 LE1 0.7 20.3 184.8 0.3 22.0 4.8 OK
B26 LE1 0.1 18.2 128.6 0.1 28.2 8.0 OK
B27 LE1 5.0 24.1 219.0 2.4 22.0 4.9 OK
B28 LE1 1.2 31.2 168.4 0.5 37.1 13.7 OK
B29 LE1 0.2 29.8 128.6 0.1 46.4 21.5 OK
B30 LE1 7.2 33.1 128.6 3.4 51.5 26.6 OK
B31 LE1 2.0 47.0 163.1 0.9 57.6 33.2 OK
B32 LE1 0.7 45.1 128.6 0.3 70.2 49.2 OK
B33 LE1 8.3 46.0 128.6 3.9 71.6 51.4 OK
B34 LE1 1.6 11.3 144.5 0.8 15.7 2.5 OK
B35 LE1 0.0 2.9 247.7 0.0 2.3 0.1 OK
B36 LE1 0.6 16.2 247.7 0.3 13.1 1.7 OK
B37 LE1 4.0 23.3 219.0 1.9 21.3 4.6 OK
B38 LE1 0.3 20.2 128.6 0.1 31.4 9.9 OK
B39 LE1 0.9 28.2 247.7 0.4 22.8 5.2 OK
B40 LE1 5.7 42.7 128.6 2.7 66.3 44.0 OK
B41 LE1 1.3 40.3 128.6 0.6 62.7 39.3 OK

8 / 90
Project:
Project no:
Author:

Tb Vsb Vdpb Utt Uts Utts


Shape Item Loads Status
[kN] [kN] [kN] [%] [%] [%]
B42 LE1 2.3 46.5 247.7 1.1 37.6 14.1 OK
B43 LE1 0.8 24.3 195.3 0.4 24.9 6.2 OK
B44 LE1 0.1 20.8 128.6 0.1 32.3 10.5 OK
B45 LE1 5.2 23.9 128.6 2.5 37.2 13.9 OK
B46 LE1 1.3 34.8 171.9 0.6 40.5 16.4 OK
B47 LE1 0.3 32.7 128.6 0.1 50.9 25.9 OK
B48 LE1 7.6 33.6 128.6 3.6 52.2 27.4 OK
B49 LE1 2.1 51.6 164.0 1.0 62.9 39.6 OK
B50 LE1 0.8 49.0 128.6 0.4 76.2 58.0 OK
B51 LE1 8.9 46.3 128.6 4.2 72.0 52.0 OK
B52 LE1 2.0 16.2 144.5 1.0 22.3 5.0 OK
B53 LE1 0.1 2.9 219.0 0.1 2.7 0.1 OK
B54 LE1 0.5 11.8 247.7 0.2 9.5 0.9 OK
B55 LE1 4.2 28.5 219.0 2.0 26.0 6.8 OK
B56 LE1 0.4 23.0 128.6 0.2 35.8 12.8 OK
B57 LE1 0.9 29.8 247.7 0.4 24.1 5.8 OK
B58 LE1 6.0 49.0 128.6 2.8 76.2 58.1 OK
B59 LE1 1.2 45.2 128.6 0.6 70.4 49.5 OK
B60 LE1 2.2 51.5 247.7 1.0 41.6 17.3 OK

Design data

Tdb Vdsb
Grade
[kN] [kN]
M24 8.8 - 1 211.0 135.3

Detailed result for B1


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 5.1 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa


​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa


​ – yield strength of the bolt
An = ​
353 mm2 – net tensile stress area of the bolt

As = 452 mm2
​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

9 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 97.4 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 322.5 kN ≥ ​ 183.7 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 403.1 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.77 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 60 mm – end distance of the fastener along bearing direction

p=∞ – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm ​ – diameter of bolt hole

t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.52 ≤ 1.0
​ ​

​ ​

Vdsb Tdb​ ​

Where:
Vsb = 97.4 kN ​ – factored shear force

Vdbs = 135.3 kN – design shear resistance


Tb = 5.1 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

10 / 90
Project:
Project no:
Author:

Detailed result for B2


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 1.7 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa
​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt


As = 452 mm2
​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 96.7 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 217.6 kN ≥ ​ 179.8 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 271.9 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 120 mm – end distance of the fastener along bearing direction


p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm
​ – diameter of bolt hole
t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

11 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.68 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 179.8 kN ​ – factored bearing force
Vdpb = 217.6 kN – design bearing resistance

Tb = 1.7 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B3


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 24.5 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = ​
452 mm2 – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 92.5 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

12 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 217.6 kN ≥ ​ 171.0 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 271.9 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 180 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate


d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole

t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.63 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 171.0 kN ​ – factored bearing force
Vdpb = 217.6 kN – design bearing resistance ​

Tb = 24.5 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B4


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 5.1 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt

An = ​

353 mm2 – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank


γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

13 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 97.4 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 322.5 kN ≥ ​ 183.7 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 403.1 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.77 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 60 mm – end distance of the fastener along bearing direction


p=∞ – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole


t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.52 ≤ 1.0
​ ​

​ ​

Vdsb Tdb​ ​

Where:
Vsb = 97.4 kN ​ – factored shear force

Vdbs = 135.3 kN – design shear resistance


Tb = 5.1 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

14 / 90
Project:
Project no:
Author:

Detailed result for B5


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 1.7 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa


​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2
​ – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 96.7 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 217.6 kN ≥ ​ 179.8 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 271.9 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 120 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm
​ – diameter of bolt hole
t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

15 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.68 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 179.8 kN ​ – factored bearing force
Vdpb = 217.6 kN – design bearing resistance

Tb = 1.7 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B6


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 24.5 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = ​
452 mm2 – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 92.5 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

16 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 217.6 kN ≥ ​ 171.0 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 271.9 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 180 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole

t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.63 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 171.0 kN ​ – factored bearing force
Vdpb = 217.6 kN – design bearing resistance ​

Tb = 24.5 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B7


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 4.8 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm ​
2 – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank


γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

17 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 97.7 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 322.5 kN ≥ ​ 184.8 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 403.1 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.77 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 60 mm – end distance of the fastener along bearing direction

p=∞ – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole


t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.52 ≤ 1.0
​ ​

​ ​

Vdsb Tdb​ ​

Where:
Vsb = 97.7 kN ​ – factored shear force

Vdbs = 135.3 kN – design shear resistance


Tb = 4.8 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

18 / 90
Project:
Project no:
Author:

Detailed result for B8


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 2.5 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa


​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2
​ – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 97.8 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 217.6 kN ≥ ​ 181.4 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 271.9 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 120 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm
​ – diameter of bolt hole

t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

19 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.70 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 181.4 kN ​ – factored bearing force
Vdpb = 217.6 kN – design bearing resistance

Tb = 2.5 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B9


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 24.9 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = ​
452 mm2 – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 91.4 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

20 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 217.6 kN ≥ ​ 168.8 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 271.9 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 181 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole

t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.62 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 168.8 kN ​ – factored bearing force

Vdpb = 217.6 kN – design bearing resistance ​

Tb = 24.9 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B10


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 4.7 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt

An = ​
353 mm2 – net tensile stress area of the bolt
As = 452 mm2 ​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

21 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 97.7 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 322.5 kN ≥ ​ 184.8 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 403.1 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.77 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 60 mm – end distance of the fastener along bearing direction

p=∞ – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole

t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.52 ≤ 1.0
​ ​

​ ​

Vdsb Tdb​ ​

Where:
Vsb = 97.7 kN ​ – factored shear force

Vdbs = 135.3 kN – design shear resistance


Tb = 4.7 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

22 / 90
Project:
Project no:
Author:

Detailed result for B11


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 2.5 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa
​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2
​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 97.8 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 217.6 kN ≥ ​ 181.4 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 271.9 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 120 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm
​ – diameter of bolt hole

t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

23 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.70 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 181.4 kN ​ – factored bearing force

Vdpb = 217.6 kN – design bearing resistance


Tb = 2.5 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B12


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 24.9 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = ​
452 mm2 – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 91.4 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

24 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 217.6 kN ≥ ​ 168.8 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 271.9 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 181 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole

t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.62 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 168.8 kN ​ – factored bearing force

Vdpb = 217.6 kN – design bearing resistance ​

Tb = 24.9 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B13


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 27.9 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt

An = ​
353 mm2 – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

25 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 93.6 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 217.6 kN ≥ ​ 183.4 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 271.9 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 930 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole

t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.73 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 183.4 kN ​ – factored bearing force

Vdpb = 217.6 kN – design bearing resistance


Tb = 27.9 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

26 / 90
Project:
Project no:
Author:

Detailed result for B14


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 3.4 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa


​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2
​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 91.0 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 217.6 kN ≥ ​ 180.3 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 271.9 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 870 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm
​ – diameter of bolt hole

t = 20 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

27 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.69 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 180.3 kN ​ – factored bearing force

Vdpb = 217.6 kN – design bearing resistance


Tb = 3.4 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B15


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 5.4 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 92.2 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

28 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 90.8 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 420 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm ​ – diameter of bolt hole

t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.50 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 90.8 kN ​ – factored bearing force

Vdpb = 128.6 kN – design bearing resistance ​

Tb = 5.4 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B16


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 27.9 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

29 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 93.6 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 217.6 kN ≥ ​ 183.4 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 271.9 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 930 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole

t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.73 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 183.4 kN ​ – factored bearing force

Vdpb = 217.6 kN – design bearing resistance


Tb = 27.9 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

30 / 90
Project:
Project no:
Author:

Detailed result for B17


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 3.4 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa


​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2
​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 91.0 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 217.6 kN ≥ ​ 180.3 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 271.9 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 870 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm
​ – diameter of bolt hole

t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

31 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.69 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 180.3 kN ​ – factored bearing force

Vdpb = 217.6 kN – design bearing resistance


Tb = 3.4 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B18


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 5.4 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 92.2 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

32 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 90.8 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 420 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole

t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.50 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 90.8 kN ​ – factored bearing force

Vdpb = 128.6 kN – design bearing resistance ​

Tb = 5.4 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B19


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 27.6 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

33 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 94.6 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 217.6 kN ≥ ​ 184.4 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 271.9 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 930 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole

t = 20 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.74 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 184.4 kN ​ – factored bearing force

Vdpb = 217.6 kN – design bearing resistance


Tb = 27.6 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

34 / 90
Project:
Project no:
Author:

Detailed result for B20


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 3.2 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa


​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2
​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 91.2 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 217.6 kN ≥ ​ 180.8 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 271.9 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 870 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm
​ – diameter of bolt hole

t = 20 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

35 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.69 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 180.8 kN ​ – factored bearing force

Vdpb = 217.6 kN – design bearing resistance


Tb = 3.2 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B21


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 5.3 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 91.1 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

36 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 90.5 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 420 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate


d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole

t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.50 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 90.5 kN ​ – factored bearing force
Vdpb = 128.6 kN – design bearing resistance ​

Tb = 5.3 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B22


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 27.6 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

37 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 94.6 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 217.6 kN ≥ ​ 184.3 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 271.9 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 930 mm – end distance of the fastener along bearing direction


p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole

t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.74 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 184.3 kN ​ – factored bearing force

Vdpb = 217.6 kN – design bearing resistance


Tb = 27.6 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

38 / 90
Project:
Project no:
Author:

Detailed result for B23


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 3.2 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa


​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2
​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 91.2 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 217.6 kN ≥ ​ 180.8 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 271.9 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 870 mm – end distance of the fastener along bearing direction


p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm
​ – diameter of bolt hole

t = 20 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

39 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.69 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 180.8 kN ​ – factored bearing force

Vdpb = 217.6 kN – design bearing resistance


Tb = 3.2 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B24


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 5.3 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank


γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 91.1 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

40 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 90.5 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 420 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole

t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.50 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 90.5 kN ​ – factored bearing force

Vdpb = 128.6 kN – design bearing resistance ​

Tb = 5.3 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B25


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 0.7 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank


γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

41 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 20.3 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 184.8 kN ≥ ​ 40.6 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 231.0 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.75 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 58 mm – end distance of the fastener along bearing direction

p=∞ – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole


t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.05 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 40.6 kN ​ – factored bearing force

Vdpb = 184.8 kN – design bearing resistance


Tb = 0.7 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

42 / 90
Project:
Project no:
Author:

Detailed result for B26


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 0.1 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa


​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2
​ – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 18.2 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 36.3 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 110 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa
​ – ultimate tensile strength of the plate
d = 24 mm – diameter of a bolt

d0 = 26 mm
​ – diameter of bolt hole
t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

43 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.08 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 36.3 kN ​ – factored bearing force

Vdpb = 128.6 kN – design bearing resistance


Tb = 0.1 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B27


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 5.0 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt


As = 452 mm2 ​ – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 24.1 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

44 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 219.0 kN ≥ ​ 48.1 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 273.7 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.88 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 201 mm – end distance of the fastener along bearing direction

p = 88 mm – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate


d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole


t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.05 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 48.1 kN ​ – factored bearing force

Vdpb = 219.0 kN – design bearing resistance ​

Tb = 5.0 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B28


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 1.2 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt


As = 452 mm2 ​ – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

45 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 31.2 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 168.4 kN ≥ ​ 62.4 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 210.5 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.68 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 53 mm – end distance of the fastener along bearing direction


p=∞ – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm ​ – diameter of bolt hole
t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.14 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 62.4 kN ​ – factored bearing force
Vdpb = 168.4 kN – design bearing resistance

Tb = 1.2 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

46 / 90
Project:
Project no:
Author:

Detailed result for B29


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 0.2 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa


​ – yield strength of the bolt
An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2
​ – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts
γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 29.8 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 59.6 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 110 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa
​ – ultimate tensile strength of the plate
d = 24 mm – diameter of a bolt
d0 = 26 mm
​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

47 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.22 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 59.6 kN ​ – factored bearing force
Vdpb = 128.6 kN – design bearing resistance

Tb = 0.2 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B30


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 7.2 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt


An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank


γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 33.1 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

48 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 66.2 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 180 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt
fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm ​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.27 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 66.2 kN ​ – factored bearing force
Vdpb = 128.6 kN – design bearing resistance ​

Tb = 7.2 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B31


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 2.0 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt


An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank


γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

49 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 47.0 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 163.1 kN ≥ ​ 93.9 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 203.9 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.66 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 51 mm – end distance of the fastener along bearing direction

p=∞ – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate


d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole


t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.33 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 93.9 kN ​ – factored bearing force

Vdpb = 163.1 kN – design bearing resistance


Tb = 2.0 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

50 / 90
Project:
Project no:
Author:

Detailed result for B32


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 0.7 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa
​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt


As = 452 mm2
​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 45.1 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 90.2 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 110 mm – end distance of the fastener along bearing direction


p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm
​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

51 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.49 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 90.2 kN ​ – factored bearing force
Vdpb = 128.6 kN – design bearing resistance

Tb = 0.7 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B33


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 8.3 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt


An = 353 mm2 ​ – net tensile stress area of the bolt
As = 452 mm2 ​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 46.0 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

52 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 92.0 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 177 mm – end distance of the fastener along bearing direction


p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm ​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.51 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 92.0 kN ​ – factored bearing force
Vdpb = 128.6 kN – design bearing resistance ​

Tb = 8.3 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B34


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 1.6 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt


An = ​
353 mm2 – net tensile stress area of the bolt
As = 452 mm2 ​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

53 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 11.3 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 144.5 kN ≥ ​ 22.6 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 180.6 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.58 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 247 mm – end distance of the fastener along bearing direction

p = 65 mm – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate


d = 24 mm – diameter of a bolt
d0 = 26 mm ​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.02 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 22.6 kN ​ – factored bearing force

Vdpb = 144.5 kN – design bearing resistance


Tb = 1.6 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

54 / 90
Project:
Project no:
Author:

Detailed result for B35


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 0.0 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa
​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt


As = 452 mm2
​ – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 2.9 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 247.7 kN ≥ ​ 5.8 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 309.6 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 1.00 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 715 mm – end distance of the fastener along bearing direction


p=∞ – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm
​ – diameter of bolt hole
t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

55 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.00 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 5.8 kN ​ – factored bearing force

Vdpb = 247.7 kN – design bearing resistance


Tb = 0.0 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B36


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 0.6 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt


As = 452 mm2 ​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 16.2 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

56 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 247.7 kN ≥ ​ 32.4 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 309.6 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 1.00 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 347 mm – end distance of the fastener along bearing direction


p = 100 mm – pitch distance of the fastener along bearing direction
fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate


d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole


t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.02 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 32.4 kN ​ – factored bearing force

Vdpb = 247.7 kN – design bearing resistance ​

Tb = 0.6 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B37


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 4.0 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm ​
2 – net tensile stress area of the bolt
As = 452 mm2 ​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

57 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 23.3 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 219.0 kN ≥ ​ 46.6 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 273.7 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.88 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 336 mm – end distance of the fastener along bearing direction


p = 88 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm ​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.05 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 46.6 kN ​ – factored bearing force
Vdpb = 219.0 kN – design bearing resistance

Tb = 4.0 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

58 / 90
Project:
Project no:
Author:

Detailed result for B38


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 0.3 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa


​ – yield strength of the bolt
An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2
​ – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 20.2 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 40.4 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 884 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa
​ – ultimate tensile strength of the plate
d = 24 mm – diameter of a bolt

d0 = 26 mm
​ – diameter of bolt hole
t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

59 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.10 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 40.4 kN ​ – factored bearing force

Vdpb = 128.6 kN – design bearing resistance


Tb = 0.3 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B39


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 0.9 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa ​ – yield strength of the bolt
An = 353 mm2 ​ – net tensile stress area of the bolt

As = ​
452 mm2 – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 28.2 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

60 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 247.7 kN ≥ ​ 56.4 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 309.6 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 1.00 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 659 mm – end distance of the fastener along bearing direction

p=∞ – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate


d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole


t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.05 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 56.4 kN ​ – factored bearing force

Vdpb = 247.7 kN – design bearing resistance ​

Tb = 0.9 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B40


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 5.7 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa ​ – yield strength of the bolt
An = 353 mm ​
2 – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank


γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

61 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 42.7 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 85.3 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 338 mm – end distance of the fastener along bearing direction


p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa ​ – ultimate tensile strength of the plate
d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole


t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.44 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 85.3 kN ​ – factored bearing force
Vdpb = 128.6 kN – design bearing resistance

Tb = 5.7 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

62 / 90
Project:
Project no:
Author:

Detailed result for B41


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 1.3 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa


​ – yield strength of the bolt
An = 353 mm2 ​ – net tensile stress area of the bolt
As = 452 mm2
​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 40.3 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 80.7 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 881 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa
​ – ultimate tensile strength of the plate
d = 24 mm – diameter of a bolt
d0 = 26 mm
​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

63 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.39 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 80.7 kN ​ – factored bearing force
Vdpb = 128.6 kN – design bearing resistance

Tb = 1.3 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B42


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 2.3 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt


An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm ​
2 – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 46.5 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

64 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 247.7 kN ≥ ​ 93.1 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 309.6 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 1.00 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 896 mm – end distance of the fastener along bearing direction


p=∞ – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm ​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.14 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 93.1 kN ​ – factored bearing force
Vdpb = 247.7 kN – design bearing resistance ​

Tb = 2.3 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B43


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 0.8 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt


An = ​
353 mm2 – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank


γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

65 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 24.3 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 195.3 kN ≥ ​ 48.6 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 244.1 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.79 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 62 mm – end distance of the fastener along bearing direction

p=∞ – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate


d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole


t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.06 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 48.6 kN ​ – factored bearing force

Vdpb = 195.3 kN – design bearing resistance


Tb = 0.8 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

66 / 90
Project:
Project no:
Author:

Detailed result for B44


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 0.1 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa
​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt


As = 452 mm2
​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 20.8 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 41.6 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 110 mm – end distance of the fastener along bearing direction


p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm
​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

67 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.10 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 41.6 kN ​ – factored bearing force
Vdpb = 128.6 kN – design bearing resistance

Tb = 0.1 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B45


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 5.2 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt


An = 353 mm2 ​ – net tensile stress area of the bolt
As = 452 mm ​
2 – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 23.9 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

68 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 47.9 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 178 mm – end distance of the fastener along bearing direction


p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm ​ – diameter of bolt hole
t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.14 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 47.9 kN ​ – factored bearing force
Vdpb = 128.6 kN – design bearing resistance ​

Tb = 5.2 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B46


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 1.3 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa ​ – yield strength of the bolt

An = ​
353 mm2 – net tensile stress area of the bolt
As = 452 mm2 ​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

69 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 34.8 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 171.9 kN ≥ ​ 69.6 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 214.9 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.69 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 54 mm – end distance of the fastener along bearing direction

p=∞ – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt
fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm ​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.16 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 69.6 kN ​ – factored bearing force
Vdpb = 171.9 kN – design bearing resistance

Tb = 1.3 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

70 / 90
Project:
Project no:
Author:

Detailed result for B47


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 0.3 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa
​ – yield strength of the bolt
An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2
​ – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 32.7 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 65.4 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 110 mm – end distance of the fastener along bearing direction


p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa
​ – ultimate tensile strength of the plate
d = 24 mm – diameter of a bolt

d0 = 26 mm
​ – diameter of bolt hole
t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

71 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.26 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 65.4 kN ​ – factored bearing force

Vdpb = 128.6 kN – design bearing resistance


Tb = 0.3 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B48


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 7.6 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt


As = ​
452 mm2 – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 33.6 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

72 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 67.2 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 174 mm – end distance of the fastener along bearing direction


p = 60 mm – pitch distance of the fastener along bearing direction
fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate


d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole


t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.27 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 67.2 kN ​ – factored bearing force

Vdpb = 128.6 kN – design bearing resistance ​

Tb = 7.6 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B49


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 2.1 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm ​
2 – net tensile stress area of the bolt
As = 452 mm2 ​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

73 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 51.6 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 164.0 kN ≥ ​ 103.2 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 205.0 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.66 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 52 mm – end distance of the fastener along bearing direction


p=∞ – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm ​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.40 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 103.2 kN ​ – factored bearing force
Vdpb = 164.0 kN – design bearing resistance

Tb = 2.1 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

74 / 90
Project:
Project no:
Author:

Detailed result for B50


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 0.8 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa


​ – yield strength of the bolt
An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm2
​ – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 49.0 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 97.9 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 110 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa
​ – ultimate tensile strength of the plate
d = 24 mm – diameter of a bolt

d0 = 26 mm
​ – diameter of bolt hole
t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

75 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.58 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 97.9 kN ​ – factored bearing force

Vdpb = 128.6 kN – design bearing resistance


Tb = 0.8 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B51


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 8.9 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa ​ – yield strength of the bolt
An = 353 mm2 ​ – net tensile stress area of the bolt

As = ​
452 mm2 – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 46.3 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

76 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 92.6 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 173 mm – end distance of the fastener along bearing direction

p = 60 mm – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate


d = 24 mm – diameter of a bolt
d0 = 26 mm ​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.52 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 92.6 kN ​ – factored bearing force

Vdpb = 128.6 kN – design bearing resistance ​

Tb = 8.9 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B52


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 2.0 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt


An = 353 mm ​
2 – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank


γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

77 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 16.2 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 144.5 kN ≥ ​ 32.3 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 180.6 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.58 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 243 mm – end distance of the fastener along bearing direction


p = 65 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa ​ – ultimate tensile strength of the plate
d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole


t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.05 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 32.3 kN ​ – factored bearing force

Vdpb = 144.5 kN – design bearing resistance


Tb = 2.0 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

78 / 90
Project:
Project no:
Author:

Detailed result for B53


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 0.1 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa
​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt


As = 452 mm2
​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 2.9 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 219.0 kN ≥ ​ 5.8 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 273.7 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.88 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 335 mm – end distance of the fastener along bearing direction

p = 88 mm – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt
fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm
​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

79 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.00 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 5.8 kN ​ – factored bearing force
Vdpb = 219.0 kN – design bearing resistance

Tb = 0.1 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B54


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 0.5 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt


An = 353 mm2 ​ – net tensile stress area of the bolt

As = 452 mm ​
2 – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts

γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 11.8 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

80 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 247.7 kN ≥ ​ 23.5 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 309.6 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 1.00 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 342 mm – end distance of the fastener along bearing direction


p = 100 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm ​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.01 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 23.5 kN ​ – factored bearing force
Vdpb = 247.7 kN – design bearing resistance ​

Tb = 0.5 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B55


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 4.2 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt


An = ​
353 mm2 – net tensile stress area of the bolt

As = 452 mm2 ​ – cross-section area at the shank


γmb = 1.25 ​ – partial safety factor for bearing type bolts
γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

81 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 28.5 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 219.0 kN ≥ ​ 56.9 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 273.7 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.88 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 288 mm – end distance of the fastener along bearing direction

p = 88 mm – pitch distance of the fastener along bearing direction


fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fu = 430.0 MPa ​ – ultimate tensile strength of the plate


d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole


t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.07 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 56.9 kN ​ – factored bearing force

Vdpb = 219.0 kN – design bearing resistance


Tb = 4.2 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

82 / 90
Project:
Project no:
Author:

Detailed result for B56


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 0.4 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa
​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt


As = 452 mm2
​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 23.0 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 46.1 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 883 mm – end distance of the fastener along bearing direction


p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa
​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm
​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

83 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.13 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 46.1 kN ​ – factored bearing force
Vdpb = 128.6 kN – design bearing resistance

Tb = 0.4 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B57


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 0.9 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa ​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt


As = 452 mm ​
2 – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 29.8 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

84 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 247.7 kN ≥ ​ 59.7 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 309.6 kN – nominal bearing strength of a bolt
​ ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 1.00 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 877 mm – end distance of the fastener along bearing direction


p=∞ – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa ​ – ultimate tensile strength of the plate

d = 24 mm – diameter of a bolt
d0 = 26 mm ​ – diameter of bolt hole
t = 12 mm – plate thickness

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.06 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 59.7 kN ​ – factored bearing force
Vdpb = 247.7 kN – design bearing resistance ​

Tb = 0.9 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B58


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 6.0 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa ​ – yield strength of the bolt

An = ​
353 mm2 – net tensile stress area of the bolt
As = 452 mm2 ​ – cross-section area at the shank

γmb = 1.25 ​ – partial safety factor for bearing type bolts


γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

85 / 90
Project:
Project no:
Author:

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 49.0 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 98.0 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN ​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 305 mm – end distance of the fastener along bearing direction


p = 60 mm – pitch distance of the fastener along bearing direction
fub = 830.0 MPa ​ – ultimate tensile strength of the bolt
fu = 430.0 MPa ​ – ultimate tensile strength of the plate
d = 24 mm – diameter of a bolt

d0 = 26 mm ​ – diameter of bolt hole


t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.58 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 98.0 kN ​ – factored bearing force
Vdpb = 128.6 kN – design bearing resistance

Tb = 6.0 kN ​ – factored tensile force

Tdb = 211.0 kN ​ – design tensile capacity of the bolt

86 / 90
Project:
Project no:
Author:

Detailed result for B59


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 1.2 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fyb = 660.0 MPa
​ – yield strength of the bolt

An = 353 mm2 ​ – net tensile stress area of the bolt


As = 452 mm2
​ – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts
γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 45.2 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 128.6 kN ≥ ​ 90.5 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 160.8 kN
​ – nominal bearing strength of a bolt ​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 0.52 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 880 mm – end distance of the fastener along bearing direction


p = 60 mm – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa
​ – ultimate tensile strength of the plate
d = 24 mm – diameter of a bolt
d0 = 26 mm
​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

87 / 90
Project:
Project no:
Author:

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.49 ≤ 1.0
​ ​

​ ​

Vdpb Tdb
​ ​

Where:
Vsb = 90.5 kN ​ – factored bearing force
Vdpb = 128.6 kN – design bearing resistance

Tb = 1.2 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Detailed result for B60


Tension resistance check (IS 800, Cl. 10.3.5)
Tnb
Tdb = = Tb =

​ ​ 211.0 kN ≥ ​ 2.2 kN
γmb ​

Where:
γmb
Tnb = min{0.9 ⋅ fub An , fyb As } = 263.7 kN – nominal tensile capacity of the bolt

​ ​ ​ ​ ​ ​

γm0 ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt

fyb = 660.0 MPa ​ – yield strength of the bolt


An = 353 mm2 ​ – net tensile stress area of the bolt
As = ​
452 mm2 – cross-section area at the shank
γmb = 1.25 ​ – partial safety factor for bearing type bolts
γm0 = 1.10 ​ – partial safety factor for resistance governed by yielding

Shear resistance check (IS 800, Cl. 10.3.3)


Vsb
Vdsb = = Vsb =

​ ​ 135.3 kN ≥ ​ 51.5 kN
γmb ​

Where:
fub
Vnsb = ⋅ An = 263.7 kN – nominal shear capacity of the bolt

3
​ ​ ​

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


An = 353 mm2 ​ – area for resisting shear in shear plane intercepted by the threads

γmb = 1.25 ​ – partial safety factor for bearing type bolts

88 / 90
Project:
Project no:
Author:

Bearing resistance check (IS 800, Cl. 10.3.4)


Vnpb
Vdpb = = Vsb =

​ ​ 247.7 kN ≥ ​ 103.0 kN
γmb ​

Where:
Vnpb = 2.5 ⋅ kb ⋅ d ⋅ t ⋅ fu = 309.6 kN ​ – nominal bearing strength of a bolt
​ ​

e p fub
kb = min{ , − 0.25, , 1.0} = 1.00 – factor for joint geometry and material strength

3 d0 3 d0
​ ​ ​ ​

fu ​ ​ ​

e = 865 mm – end distance of the fastener along bearing direction


p=∞ – pitch distance of the fastener along bearing direction

fub = 830.0 MPa ​ – ultimate tensile strength of the bolt


fu = 430.0 MPa ​ – ultimate tensile strength of the plate
d = 24 mm – diameter of a bolt
d0 = 26 mm ​ – diameter of bolt hole

t = 12 mm – plate thickness
γmb = 1.25 ​ – partial safety factor for bearing type bolts

Interaction of tension and shear check (IS 800, Cl. 10.3.6)

Vsb 2 Tb 2
( ) +( ) = 0.17 ≤ 1.0
​ ​

​ ​

Vdpb Tdb​ ​

Where:
Vsb = 103.0 kN ​ – factored bearing force
Vdpb = 247.7 kN – design bearing resistance

Tb = 2.2 kN ​ – factored tensile force


Tdb = 211.0 kN ​ – design tensile capacity of the bolt

Buckling
Buckling analysis was not calculated.

Symbol explanation
Symbol Symbol explanation
εPl Strain
f Design yield strength
εlim Limit of plastic strain
Tb Factored tensile force
Vsb Factored shear force
Vdpb Design bearing capacity of the bolt - IS 800, Cl. 10.3.4
Ut Utilization
Uts Utilization in shear
Utts Utilization in combined tension and shear - IS 800, Cl. 10.3.6
Tdb Design tensile capacity of the bolt - IS 800, Cl. 10.3.5
Vdsb Design shear capacity of the bolt - IS 800, Cl. 10.3.3

89 / 90
Project:
Project no:
Author:

Code settings
Item Value Unit Reference
Friction coefficient - concrete 0.45 - IS 800, Cl. 7.4.1
Friction coefficient in slip-resistance 0.30 - IS 800, Cl. 10.4.3
Limit plastic strain 0.05 -
Detailing No
Distance between bolts [d] 2.50 - IS 800, Cl. 10.2.2
Distance between bolts and edge [d] 1.50 - IS 800, Cl. 10.2.4
Limit grip length of bolts as a multiple of bolt diameter - IS 800, Cl.
Bolt maximum grip length [d] 8.00 -
10.3.3.2
Local deformation check Yes
Local deformation limit 0.03 - CIDECT DG 1, 3 - 1.1
Geometrical nonlinearity (GMNA) Yes Analysis with large deformations for hollow section joints
IS800, Cl
Concrete in compression check
7.4
Braced system (EC stiffness
No EN1993-1-8 - Cl. 5.2.2.5
classification)

90 / 90