Professional Documents
Culture Documents
NM Roof Floor Deck Load Table
NM Roof Floor Deck Load Table
NM Roof Floor Deck Load Table
VERSION 5.0
Design Guide
Steel Roof
and Floor Deck
Table of Contents
Roof Deck
Composite Deck
Deep-Dek®
Long-Span Composite
Versa-Dek®
Form Deck
Typical Fastener Layouts
General Information
This catalog was produced by New Millennium to assist specifiers and consumers
in the application of deck products produced by New Millennium.
LIABILITY STATEMENT
Code of Standard Practice
The data published in this design guide has been developed using recognized engineering principles and is intended for general information only.
Although the data shown is believed to be accurate, New Millennium Building Systems does not assume any liability or obligation of any kind or nature
arising from or related to the data provided herein and/or its use. Applicability of the products and the accuracy of the data should be assessed by a
licensed professional engineer or architect to determine the suitability for the intended application. New Millennium Building Systems’ Standard Terms
and Conditions shall supersede any statements to the contrary contained herein.
Table of Contents
Table of Contents
Roof Deck
Roof Deck. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.0RD Deck.......................................................................................................................... 6
F Deck................................................................................................................................... 7
Composite Deck
B Deck..........................................................................................................................8 – 13
NW32® and N Deck............................................................................................... 14 – 26
Curve-Dek................................................................................................................. 27 – 30
Versa-Dek®................................................................................................................ 31 – 36
Super Versa-Dek®..................................................................................................... 37 – 38
Deep-Dek®................................................................................................................ 39 – 57
Versa-Dek®
Long-Span Composite
Composite Deck. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Standard Composite................................................................................................ 60 – 67
Deep-Dek®
Cellular Composite................................................................................................... 68 – 91
Form Deck
Form Deck. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
0.6 and 1.0 Form Deck............................................................................................ 96 – 99
EHD-Dek............................................................................................................... 100 – 101
1.5, 2.0, and 3.0 Form Deck............................................................................... 102 – 109
Standard Accessories.......................................................................................................117
Floor Deck Accessory Details..........................................................................................118
Pour Stop Gage Selection...............................................................................................119
Bill of Materials...................................................................................................... 120 – 121
Factory Mutual Approved Steel Decks.......................................................................... 122
Code of Standard Practice
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 3
Long-Span Composite
Code of Standard Practice General Information Typical Fastener Layouts Form Deck Composite Deck Roof Deck Table of Contents
Versa-Dek® Deep-Dek®
Roof Deck
Table of Contents
Roof deck is available in a range of profiles and options. Deck products meet
required steel deck certifications and are manufactured in accordance with the
specifications of the Steel Deck Institute. Click on the links below to view load tables.
Roof Deck
1.0RD Deck........................................................................................................................... 6
1-inch standard and vented deck available
F Deck..................................................................................................................................... 7
Composite Deck
B Deck.............................................................................................................................8 – 9
Standard, interlocking, and vented variations,
available with or without acoustical properties
Versa-Dek®
Long-Span Composite
NW32®.........................................................................................................................14 –17
Standard and interlocking available,
with or without acoustical properties
Deep-Dek®
Standard N Deck................................................................................................... 18 – 19
Standard and acoustical available
N-Dek.........................................................................................................................20 – 26
Standard, cellular, and inverted variations,
Form Deck
available with or without acoustical properties
Curve-Dek®..............................................................................................................27 – 30
Standard and cellular variations, available
with or without acoustical properties
Versa-Dek® 3.5.......................................................................................................35 – 36
3.5-inch dovetail deck, available with
or without acoustical properties
General Information
Super Versa-Dek® 6.5.....................................................................................37 – 38
A dovetail hybrid structural deck, available
with or without acoustical properties
Deep-Dek®......................................................................................................... 39 – 44
4.5-inch, 6-inch, and 7.5-inch single cell (hat) unit deck,
available with or without acoustical properties
Code of Standard Practice
Deep-Dek® Cellular..........................................................................................45 – 57
4.5-inch, 6-inch, and 7.5-inch single cell (hat) unit deck with
a liner panel, available with or without acoustical properties
newmill.com 5
1.0RD, 1.0RDV Deck
Table of Contents
20 0.0358 1.87
ICC-ES APPROVED
REFER TO ESR-3818
24 60 0.056 0.056 0.056 0.056 0.098 0.105 3518 3782 2739 789 1422
22 60 0.070 0.070 0.070 0.070 0.129 0.132 4631 4744 3388 1169 2126
20 60 0.085 0.085 0.085 0.085 0.160 0.160 5749 5749 4101 1665 3047
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite
3 -0 3 -6 4 -0 4 -6 5 -0 5 -6 6 -0 6 -6 7 -0 8 -0 (ctr / ctr)
26 180 / 101 132 / 64 101 / 43 - - - - - - - 4-0
24 261 / 137 191 / 86 147 / 58 116 / 41 94 / 30 78 / 22 65 / 17 - - - 5-9
Single
22 343 / 170 252 / 107 193 / 72 152 / 50 123 / 37 102 / 28 86 / 21 73 / 17 63 / 13 48 / 9 7-6
20 426 / 206 313 / 130 240 / 87 189 / 61 153 / 45 127 / 33 106 / 26 91 / 20 78 / 16 60 / 11 9-2
26 185 / 244 136 / 154 105 / 103 83 / 72 67 / 53 - - - - - 4 - 11
Form Deck
20 518 / 389 383 / 245 295 / 164 234 / 115 190 / 84 157 / 63 132 / 49 113 / 38 97 / 31 75 / 21 11 - 4
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information
20 60 1-2 1-2 1-2 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
6 www.newmill.com/digital-tools
F Deck
Table of Contents
Roof Decks - Type F
PROPERTIES
7
Thickness Cover Weight 18 ˝
Gage
(in) (in) (psf)
22 0.0295 1.58 1 21 ˝
5 6˝
20 0.0358 1.92 8˝
36
18 0.0474 2.54 36˝ Coverage
Roof Deck
16 0.0598 3.21
ICC-ES APPROVED
REFER TO ESR-3818
Composite Deck
20 40 0.151 0.155 0.149 0.155 0.136 0.146 3266 3494 2579 887 1641
18 40 0.205 0.205 0.205 0.205 0.186 0.192 4447 4595 3395 1483 2761
16 40 0.259 0.259 0.259 0.259 0.238 0.240 5700 5755 4257 2269 4240
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
4 -0 4 -6 5 -0 5 -6 6 -0 6 -6 7 -0 8 -0 9 -0 10 - 0 (ctr / ctr)
22 110 / 124 87 / 87 - - - - - - - - 4-3
20 136 / 155 108 / 109 87 / 79 72 / 60 - - - - - - 5-3
Single
18 185 / 210 146 / 147 119 / 107 98 / 81 82 / 62 70 / 49 61 / 39 46 / 26 - - 7-1
16 238 / 265 188 / 186 152 / 136 126 / 102 106 / 78 90 / 62 78 / 49 59 / 33 47 / 23 - 8 - 10
22 119 / 316 94 / 222 77 / 162 63 / 122 - - - - - - 5-3
Form Deck
20 144 / 383 114 / 269 93 / 196 77 / 147 64 / 114 55 / 89 - - - - 6-6
Double
18 190 / 507 150 / 356 122 / 260 101 / 195 85 / 150 72 / 118 62 / 95 48 / 63 38 / 45 - 8-8
16 237 / 639 188 / 449 153 / 327 126 / 246 106 / 189 90 / 149 78 / 119 60 / 80 47 / 56 38 / 41 10 - 9
22 148 / 247 118 / 174 95 / 127 79 / 95 - - - - - - 5-4
20 179 / 300 142 / 211 115 / 154 96 / 115 80 / 89 69 / 70 59 / 56 - - - 6-7
Triple
18 236 / 397 187 / 279 152 / 203 126 / 153 106 / 118 90 / 92 78 / 74 60 / 50 47 / 35 - 8-9
16 40 2-2 2-2 2-2 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 7
B, BI, BV, BIV Deck
Table of Contents
20 40 0.205 0.213 0.201 0.213 0.224 0.235 5375 5624 2428 932 1696
18 40 0.280 0.281 0.279 0.281 0.304 0.315 7291 7553 3192 1557 2858
16 40 0.355 0.355 0.355 0.355 0.390 0.395 9332 9454 3996 2381 4396
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite
5 -0 5 -6 6 -0 6 -6 7 -0 8 -0 9 -0 10 - 0 11 - 0 12 - 0 (ctr / ctr)
22 112 / 86 93 / 64 78 / 50 67 / 39 57 / 31 - - - - - 6 - 10
20 143 / 107 118 / 81 100 / 62 85 / 49 73 / 39 56 / 26 44 / 18 - - - 8-7
Single
18 194 / 147 161 / 110 135 / 85 115 / 67 99 / 54 76 / 36 60 / 25 49 / 18 40 / 14 34 / 11 11 - 3
16 249 / 186 206 / 140 173 / 108 147 / 85 127 / 68 97 / 45 77 / 32 62 / 23 51 / 17 43 / 13 13 - 11
22 115 / 221 95 / 166 80 / 128 69 / 101 59 / 81 45 / 54 36 / 38 - - - 8-4
Form Deck
16 307 / 351 255 / 264 215 / 203 183 / 160 159 / 128 122 / 86 96 / 60 78 / 44 65 / 33 54 / 25 17 - 1
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information
16 40 3-1 2-7 2-7 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
8 www.newmill.com/digital-tools
BA, BIA Deck
Table of Contents
Roof Decks - Types BA, BIA
PROPERTIES 2 21 ˝
Thickness Cover Weight
Gage
(in) (in) (psf)
22 0.0295 1.56 1 21 ˝
20 0.0358 1.89 6˝
36 1 85 ˝
18 0.0474 2.50
Roof Deck
16 0.0598 3.16 36˝ Coverage
ICC-ES APPROVED
REFER TO ESR-3818
Composite Deck
20 40 0.200 0.206 0.196 0.206 0.217 0.223 5198 5353 1631 898 1687
18 40 0.272 0.273 0.272 0.273 0.293 0.301 7013 7201 2136 1508 2845
16 40 0.344 0.344 0.344 0.344 0.373 0.376 8935 9015 2664 2314 4378
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers applied in accordance with
SDI white paper ''Perforated Metal Deck Design with Commentary''.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
5 -0 5 -6 6 -0 6 -6 7 -0 8 -0 9 -0 10 - 0 11 - 0 12 - 0 (ctr / ctr)
22 109 / 83 90 / 63 75 / 48 64 / 38 55 / 30 - - - - - 6-7
20 139 / 105 115 / 79 96 / 61 82 / 48 71 / 38 54 / 26 43 / 18 - - - 8-4
Single
18 187 / 143 155 / 107 130 / 83 111 / 65 95 / 52 73 / 35 58 / 24 47 / 18 39 / 13 - 10 - 11
16 238 / 180 197 / 136 165 / 104 141 / 82 122 / 66 93 / 44 74 / 31 60 / 23 49 / 17 41 / 13 13 - 5
22 107 / 214 89 / 161 75 / 124 64 / 98 56 / 78 43 / 52 34 / 37 - - - 8-1
Form Deck
20 138 / 261 114 / 196 97 / 151 83 / 119 71 / 95 55 / 64 44 / 45 35 / 33 29 / 25 - 10 - 2
Double
18 185 / 345 154 / 259 130 / 200 111 / 157 96 / 126 74 / 84 59 / 59 48 / 43 39 / 32 33 / 25 13 - 4
16 231 / 435 192 / 327 163 / 252 139 / 198 120 / 159 92 / 106 73 / 75 60 / 54 49 / 41 41 / 31 16 - 4
22 132 / 168 110 / 126 93 / 97 80 / 76 69 / 61 53 / 41 42 / 29 - - - 8-2
20 170 / 204 141 / 153 120 / 118 102 / 93 89 / 74 68 / 50 54 / 35 44 / 26 36 / 19 - 10 - 4
Triple
18 227 / 270 190 / 203 160 / 156 137 / 123 119 / 98 92 / 66 73 / 46 59 / 34 49 / 25 41 / 20 13 - 6
16 40 3-0 2-7 2-6 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 9
B-Dek Cellular
Table of Contents
20/18 40 0.438 0.466 0.420 0.462 0.315 0.456 7538 10921 2303 915 1618
18/20 40 0.510 0.510 0.502 0.476 0.444 0.563 10635 13480 3028 1530 2745
18/18 40 0.561 0.562 0.552 0.554 0.459 0.587 10987 14049 3028 1530 2745
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite
6 -0 7 -0 8 -0 9 -0 10 - 0 11 -0 12 - 0 13 - 0 14 - 0 15 - 0 (ctr / ctr)
20/20 134 / 121 99 / 76 76 / 51 60 / 36 48 / 26 40 / 20 - - - - 11 - 0
20/18 140 / 133 103 / 84 79 / 56 62 / 39 50 / 29 42 / 22 35 / 17 - - - 11 - 3
Single
18/20 197 / 155 145 / 97 111 / 65 88 / 46 71 / 33 59 / 25 49 / 19 42 / 15 36 / 12 32 / 10 15 - 3
18/18 203 / 170 149 / 107 114 / 72 90 / 50 73 / 37 61 / 28 51 / 21 43 / 17 37 / 13 33 / 11 15 - 5
20/20 185 / 299 137 / 188 106 / 126 84 / 89 68 / 65 57 / 49 48 / 37 41 / 29 35 / 24 - 13 - 4
Form Deck
18/18 40 4-6 3-6 3-5 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
10 www.newmill.com/digital-tools
B-Dek Cellular
Table of Contents
Roof Decks - Type BDC Cellular
PROPERTIES 6˝
6˝ 2 21˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)
1 21 ˝
18/16 0.0474/0.0598 5.28
16/18 0.0598/0.0474 24.5 5.35 185 ˝
24 21 ˝ Coverag
16/16 0.0598/0.0598 5.93 24 21 ˝ Coverage
Roof Deck
ICC-ES APPROVED
REFER TO ESR-1169
Composite Deck
16/18 40 0.677 0.677 0.676 0.643 0.631 0.724 15108 17337 3790 2342 4241
16/16 40 0.735 0.735 0.734 0.730 0.648 0.751 15519 17978 3790 2342 4241
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
6 -0 7 -0 8 -0 9 -0 10 -0 11 - 0 12 -0 13 -0 14 -0 15 -0 (ctr / ctr)
18/16 209 / 185 153 / 116 117 / 78 93 / 55 75 / 40 62 / 30 52 / 23 44 / 18 38 / 15 33 / 12 15 - 7
Single 16/18 280 / 205 206 / 129 157 / 87 124 / 61 101 / 44 83 / 33 70 / 26 60 / 20 51 / 16 45 / 13 19 - 10
16/16 287 / 223 211 / 141 162 / 94 128 / 66 103 / 48 86 / 36 72 / 28 61 / 22 53 / 18 46 / 14 19 - 11
18/16 256 / 459 191 / 289 147 / 193 117 / 136 95 / 99 79 / 74 67 / 57 57 / 45 49 / 36 43 / 29 18 - 9
Double 16/18 306 / 495 228 / 312 176 / 209 140 / 147 114 / 107 94 / 80 79 / 62 68 / 49 58 / 39 51 / 32 23 - 10
Form Deck
16/16 316 / 538 235 / 339 182 / 227 145 / 159 118 / 116 97 / 87 82 / 67 70 / 53 61 / 42 53 / 34 23 - 10
18/16 313 / 359 234 / 226 182 / 151 145 / 106 117 / 78 97 / 58 82 / 45 70 / 35 60 / 28 52 / 23 19 - 0
Triple 16/18 375 / 388 280 / 244 217 / 164 173 / 115 141 / 84 117 / 63 99 / 48 84 / 38 73 / 31 63 / 25 24 - 1
16/16 387 / 421 290 / 265 224 / 178 179 / 125 146 / 91 121 / 68 102 / 53 87 / 41 75 / 33 66 / 27 24 - 2
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
General Information
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 11
B-Dek Cellular Acoustical
Table of Contents
20/18 40 0.426 0.459 0.409 0.459 0.313 0.456 7489 10914 2303 915 1618
18/20 40 0.495 0.495 0.487 0.476 0.441 0.563 10561 13487 3028 1530 2745
18/18 40 0.544 0.554 0.536 0.550 0.456 0.586 10913 14044 3028 1530 2745
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite
6 -0 7 -0 8 -0 9 -0 10 - 0 11 -0 12 - 0 13 - 0 14 - 0 15 - 0 (ctr / ctr)
20/20 133 / 118 98 / 74 75 / 50 59 / 35 48 / 25 40 / 19 - - - - 10 - 11
20/18 139 / 129 102 / 81 78 / 55 62 / 38 50 / 28 41 / 21 35 / 16 - - - 11 - 2
Single
18/20 196 / 150 144 / 95 110 / 63 87 / 44 70 / 32 58 / 24 49 / 19 42 / 15 36 / 12 31 / 10 15 - 3
18/18 202 / 165 148 / 104 114 / 70 90 / 49 73 / 36 60 / 27 51 / 21 43 / 16 37 / 13 32 / 11 15 - 5
20/20 185 / 296 137 / 186 106 / 125 84 / 88 69 / 64 57 / 48 48 / 37 41 / 29 35 / 23 - 13 - 4
Form Deck
18/18 40 4-6 3-5 3-5 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
12 www.newmill.com/digital-tools
B-Dek Cellular Acoustical
Table of Contents
Roof Decks - Type BDCA Cellular
PROPERTIES Roof Decks - Type
6˝
BDCA Cellular
6˝ 2 21 ˝
PROPERTIES
Gage 2 21˝
Thickness Cover Weight
(Hat/Pan)
Gage (in)
Thickness (in) 1 Weight
Cover (psf) 1 21 ˝
12 ˝
18/16 0.0474/0.0598
(Top/Bot) (in) (in) 5.05
(psf)
185 ˝
16/18 185 ˝
18/16 0.0598/0.0474
0.0474/0.0598 24.5 5.16
5.05
1 24 21 ˝ Coverage
16/18 0.0598/0.0598
24 2 ˝ Coverage
16/16 0.0598/0.0474 24.5 5.70
5.16
Roof Deck
ICC-ES APPROVED
16/16 0.0598/0.0598 5.70 REFER TO ESR-1169
Available with optional plastic lath to protect acoustical properties of the deck when painting in the field.
Composite Deck
16/18
18/16 40
40 0.657
0.591 0.657
0.609 0.655
0.582 0.640
0.609 0.626
0.469 0.724
0.608 15001
11243 17336
14558 3790
3028 2342
1530 4241
2745
16/16
16/18 40
40 0.713
0.657 0.717
0.657 0.712
0.655 0.717
0.640 0.643
0.626 0.750
0.724 15412
15001 17957
17336 3790
3790 2342
2342 4241
4241
16/16 40 0.713 1. Section
Notes: 0.717 properties
0.712are calculated
0.717 in accordance
0.643 with the
0.750 15412
AISI S100-16, 17957 modifiers.
with perforation 3790 2342 4241
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM
ALLOWABLE UNIFORM LOADS
LOADS AND
AND MAXIMUM
MAXIMUM CONSTRUCTION
CONSTRUCTION SPANS
SPANS
AllowableUniform
Allowable UniformTotal
TotalLoad
Load(psf)
(psf)//Load
Loadthat
thatProduces
ProducesL/240
L/240Deflection
Deflection(psf)
(psf) SDI Max.
SDI Max.
Span
Span Constr.
Constr.
Gage
Gage Centerto
Center toCenter
CenterSpan
Span(ft
(ft--in)
in)
Condition
Condition Span
Span
Deep-Dek®
66 -- 00 77 -- 00 88 -- 00 99 -- 00 10 -- 00
10 11 -- 00
11 12 -- 00
12 13 -- 00
13 14 -- 00
14 15 -- 00
15 (ctr // ctr)
(ctr ctr)
18/16
18/16 208 // 179
208 179 153 // 113
153 113 117 // 76
117 76 93 // 53
93 53 75 // 39
75 39 62 // 29
62 29 52
52 // 22
22 44 // 18
44 18 38 // 14
38 14 33 // 11
33 11 18--78
15
Single
Single 16/18
16/18 278 // 199
278 199 204 // 125
204 125 156 // 84
156 84 123 // 59
123 59 100 // 43
100 43 83 // 32
83 32 69
69 // 25
25 59 // 20
59 20 51 // 16
51 16 44 // 13
44 13 25- -10
19 0
16/16
16/16 285 // 216
285 216 210 // 136
210 136 161 // 91
161 91 127 // 64
127 64 103 // 47
103 47 85 // 35
85 35 71
71 // 27
27 61 // 21
61 21 52 // 17
52 17 46 // 14
46 14 25- -11
19 8
18/16
18/16 256 // 446
256 446 190 // 281
190 281 147 // 188
147 188 117 // 132
117 132 95 // 96
95 96 79 // 72
79 72 66
66 // 56
56 57 // 44
57 44 49 // 35
49 35 43 // 29
43 29 23- -10
18 0
Double
Double 16/18
16/18 306 // 481
306 481 228 // 303
228 303 176 // 203
176 203 140 // 142
140 142 114 // 104
114 104 94 // 78
94 78 79
79 // 60
60 68 // 47
68 47 58 // 38
58 38 51 // 31
51 31 30- -10
23 9
Form Deck
16/16
16/16 316 /
316 / 524524 235 /
235 / 330330 182 /
182 / 221221 144 /
144 / 155155 117 / 113
117 / 113 97 /
97 / 8585 82 /
82 / 6666 70 /
70 / 5252 60 /
60 / 4141 53 /
53 / 3434 31 -
23 - 117
18/16
18/16 313 // 349
313 349 234 // 220
234 220 182 // 147
182 147 145 // 103
145 103 117 // 75
117 75 97 // 57
97 57 81
81 // 44
44 69 // 34
69 34 60 // 27
60 27 52 // 22
52 22 23--15
19
Triple
Triple 16/18
16/18 375 // 376
375 376 280 // 237
280 237 217 // 159
217 159 173 // 111
173 111 141 // 81
141 81 117 // 61
117 61 99
99 // 47
47 84 // 37
84 37 73 // 30
73 30 63 // 24
63 24 31--23
24
16/16
16/16 387 // 410
387 410 289 // 258
289 258 224 // 173
224 173 179 // 122
179 122 146 // 89
146 89 121 // 67
121 67 102
102 // 51
51 87 // 40
87 40 75 // 32
75 32 66 // 26
66 26 32--21
24
Notes: 3.3. Allowable
Notes: AllowableUniform
UniformLoads
Loadsand
andmaximum
maximumconstruction
constructionspans
spansshown
shownare
arebased
basedon
onthe
thefollowing
followingcriteria:
criteria:
●● ANSI/SDI
ANSI/SDIRD-2017
RD-2017Standard
StandardforforSteel
SteelRoof
RoofDeck
Deck
●● Minimum
Minimumbearing
bearinglengths
lengthsofof111/2''
1/2''for
forend
endbearing
bearingandand3''
3''for
forinterior
interiorbearing.
bearing. Check
Checkwebwebcrippling
cripplingififminimums
minimumsare arenot
notmet.
met.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 13
NW32®
Table of Contents
ICC-ES APPROVED
16 0.0598 3.76 REFER TO ESR-4655
20 50 0.875 0.935 0.836 0.926 0.457 0.496 13691 14842 3779 777 1559
18 50 1.213 1.254 1.192 1.252 0.672 0.711 20109 21279 6618 1317 2624
16 50 1.568 1.581 1.561 1.581 0.902 0.937 27015 28060 9158 2032 4030
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite
8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 - 0 20 - 0 (ctr / ctr)
22 110 / 89 70 / 45 58 / 34 49 / 26 42 / 21 36 / 17 31 / 13 27 / 11 - - 17 - 6
20 143 / 112 91 / 57 75 / 43 63 / 33 54 / 26 47 / 21 41 / 17 36 / 14 28 / 10 23 / 7 22 - 9
Single
18 209 / 155 134 / 80 111 / 60 93 / 46 79 / 36 68 / 29 60 / 24 52 / 19 41 / 14 34 / 10 33 - 6
16 281 / 201 180 / 103 149 / 77 125 / 59 107 / 47 92 / 37 80 / 30 70 / 25 56 / 18 45 / 13 40 - 0
22 109 / 233 75 / 119 62 / 90 53 / 69 45 / 54 39 / 43 34 / 35 30 / 29 24 / 20 - 21 - 7
Form Deck
16 359 / 382 231 / 196 191 / 147 161 / 113 137 / 89 119 / 71 103 / 58 - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for a nominal 200 lbs. concentrated load supported by a one foot section of deck per SDI criteria,
which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per Section
1607.4 and Table 1607.1.
5. Values in RED are shown for use in determining deck capacity under deflection limits more stringent than Span/240. The total loads shown
are not to be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information
16 50 6-0 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
14 www.newmill.com/digital-tools
NW32A®
Table of Contents
Roof Decks - Type NW32A
PROPERTIES
Thickness Cover Weight
Gage
(in) (in) (psf)
22 0.0295 1.76
20 0.0358 2.14
32
18 0.0474 2.82
Roof Deck
ICC-ES APPROVED
16 0.0598 3.56 REFER TO ESR-4655
Composite Deck
20 50 0.850 0.908 0.813 0.900 0.438 0.470 13099 14085 2832 742 1550
18 50 1.181 1.219 1.161 1.218 0.649 0.680 19423 20354 4958 1267 2610
16 50 1.526 1.537 1.520 1.537 0.874 0.900 26176 26954 6857 1965 4012
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers applied in accordance with
SDI white paper ''Perforated Metal Deck Design with Commentary''.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
8 -0 10 -0 11 -0 12 -0 13 - 0 14 -0 15 -0 16 -0 18 - 0 20 - 0 (ctr / ctr)
22 104 / 86 67 / 44 55 / 33 46 / 26 40 / 20 34 / 16 30 / 13 26 / 11 - - 16 - 8
20 136 / 109 87 / 56 72 / 42 61 / 32 52 / 25 45 / 20 39 / 17 34 / 14 27 / 10 - 21 - 9
Single
18 202 / 151 129 / 77 107 / 58 90 / 45 77 / 35 66 / 28 58 / 23 51 / 19 40 / 13 32 / 10 32 - 4
16 273 / 195 175 / 100 144 / 75 121 / 58 103 / 46 89 / 36 78 / 30 68 / 24 54 / 17 44 / 13 40 - 0
22 106 / 226 69 / 116 58 / 87 49 / 67 42 / 53 36 / 42 31 / 34 28 / 28 22 / 20 - 20 - 6
Form Deck
20 142 / 280 92 / 144 76 / 108 64 / 83 55 / 65 47 / 52 41 / 43 36 / 35 29 / 25 23 / 18 26 - 10
Double
18 207 / 376 134 / 193 111 / 145 93 / 112 80 / 88 69 / 70 60 / 57 53 / 47 42 / 33 34 / 24 39 - 10
16 275 / 475 177 / 243 147 / 183 124 / 141 105 / 111 91 / 89 79 / 72 70 / 59 55 / 42 45 / 30 40 - 0
22 123 / 177 86 / 91 71 / 68 60 / 52 52 / 41 45 / 33 39 / 27 - - - 20 - 10
20 175 / 219 114 / 112 95 / 84 80 / 65 68 / 51 59 / 41 51 / 33 - - - 27 - 3
Triple
18 257 / 295 166 / 151 138 / 113 116 / 87 99 / 69 86 / 55 75 / 45 - - - 40 - 0
16 50 6-0 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 15
NW32I®
Table of Contents
ICC-ES APPROVED
16 0.0598 3.80 REFER TO ESR-4655
20 50 0.864 0.936 0.826 0.933 0.451 0.514 13517 15383 3779 777 1559
18 50 1.199 1.242 1.178 1.242 0.663 0.721 19856 21582 6618 1317 2624
16 50 1.549 1.562 1.543 1.562 0.890 0.934 26654 27967 9158 2032 4030
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite
8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 - 0 20 - 0 (ctr / ctr)
22 109 / 88 69 / 45 57 / 34 48 / 26 41 / 20 35 / 16 31 / 13 27 / 11 - - 17 - 4
20 141 / 111 90 / 57 74 / 43 63 / 33 53 / 26 46 / 21 40 / 17 35 / 14 28 / 10 23 / 7 22 - 6
Single
18 207 / 154 132 / 79 109 / 59 92 / 45 78 / 36 68 / 29 59 / 23 52 / 19 41 / 13 33 / 10 33 - 1
16 278 / 198 178 / 102 147 / 76 123 / 59 105 / 46 91 / 37 79 / 30 69 / 25 55 / 17 44 / 13 40 - 0
22 109 / 235 79 / 120 65 / 90 55 / 70 47 / 55 41 / 44 35 / 36 31 / 29 25 / 21 - 21 - 4
Form Deck
16 358 / 377 230 / 193 191 / 145 161 / 112 137 / 88 118 / 70 103 / 57 - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for a nominal 200 lbs. concentrated load supported by a one foot section of deck per SDI criteria,
which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per Section
1607.4 and Table 1607.1.
5. Values in RED are shown for use in determining deck capacity under deflection limits more stringent than Span/240. The total loads shown
are not to be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information
16 50 6-0 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
16 www.newmill.com/digital-tools
NW32IA®
Table of Contents
Roof Decks - Type NW32IA
PROPERTIES
Thickness Cover Weight
Gage
(in) (in) (psf)
22 0.0295 1.78
20 0.0358 2.16
32
18 0.0474 2.86
Roof Deck
ICC-ES APPROVED
16 0.0598 3.60 REFER TO ESR-4655
Composite Deck
20 50 0.840 0.909 0.803 0.906 0.432 0.490 12930 14663 2832 742 1550
18 50 1.167 1.208 1.147 1.208 0.640 0.691 19172 20687 4958 1267 2610
16 50 1.507 1.519 1.502 1.519 0.862 0.898 25816 26881 6857 1965 4012
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers applied in accordance with
SDI white paper ''Perforated Metal Deck Design with Commentary''.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 - 0 20 - 0 (ctr / ctr)
22 103 / 85 66 / 44 55 / 33 46 / 25 39 / 20 34 / 16 29 / 13 26 / 11 - - 16 - 6
20 135 / 108 86 / 55 71 / 41 60 / 32 51 / 25 44 / 20 38 / 16 34 / 13 27 / 9 - 21 - 6
Single
18 200 / 149 128 / 77 106 / 57 89 / 44 76 / 35 65 / 28 57 / 23 50 / 19 39 / 13 32 / 10 31 - 11
16 269 / 193 172 / 99 142 / 74 120 / 57 102 / 45 88 / 36 76 / 29 67 / 24 53 / 17 43 / 12 40 - 0
22 108 / 228 74 / 117 61 / 88 52 / 68 44 / 53 38 / 43 33 / 35 29 / 29 23 / 20 - 20 - 3
Form Deck
20 147 / 281 96 / 144 79 / 108 67 / 83 57 / 65 49 / 52 43 / 43 38 / 35 30 / 25 24 / 18 26 - 6
Double
18 211 / 373 136 / 191 113 / 143 95 / 110 81 / 87 70 / 70 61 / 57 54 / 47 42 / 33 34 / 24 39 - 4
16 274 / 469 177 / 240 146 / 180 123 / 139 105 / 109 91 / 87 79 / 71 70 / 59 55 / 41 45 / 30 40 - 0
22 123 / 179 90 / 91 75 / 69 64 / 53 55 / 42 47 / 33 41 / 27 - - - 20 - 7
20 176 / 220 118 / 112 98 / 85 83 / 65 71 / 51 61 / 41 54 / 33 - - - 26 - 11
Triple
18 261 / 292 169 / 149 140 / 112 118 / 86 101 / 68 87 / 54 76 / 44 - - - 39 - 11
16 50 6-0 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 17
Standard N Deck
Table of Contents
ICC-ES APPROVED
16 0.0598
24˝ Coverage 4.14 24˝ Coverage REFER TO ESR-3818
20 40 0.968 1.085 0.908 1.083 0.487 0.544 11654 13030 3592 666 1308
18 40 1.352 1.440 1.309 1.440 0.687 0.753 16456 18039 5663 1128 2208
16 40 1.768 1.814 1.745 1.814 0.890 0.951 21312 22767 7115 1740 3400
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite
8 -0 10 -0 11 -0 12 - 0 13 -0 14 -0 15 - 0 16 - 0 18 - 0 20 - 0 (ctr / ctr)
22 93 / 97 59 / 50 49 / 37 41 / 29 35 / 23 30 / 18 - - - - 13 - 10
20 121 / 124 78 / 63 64 / 48 54 / 37 46 / 29 40 / 23 35 / 19 30 / 15 24 / 11 - 17 - 6
Single
18 171 / 173 110 / 89 91 / 67 76 / 51 65 / 40 56 / 32 49 / 26 43 / 22 34 / 15 27 / 11 23 - 0
16 222 / 226 142 / 116 117 / 87 99 / 67 84 / 53 72 / 42 63 / 34 55 / 28 44 / 20 36 / 14 27 - 7
22 91 / 274 67 / 140 56 / 105 47 / 81 40 / 64 34 / 51 30 / 42 26 / 34 - - 16 - 10
Form Deck
16 291 / 438 187 / 224 155 / 169 131 / 130 111 / 102 96 / 82 84 / 67 - - - 33 - 5
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information
16 40 6-2 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
18 www.newmill.com/digital-tools
Standard N Deck Acoustical
Table of Contents
Roof Decks - Type NA
PROPERTIES
Thickness Cover Weight 2 85 ˝ 2 85 ˝
Gage
(in) (in) (psf)
22 0.0295 1.92 3˝ 3˝
20 0.0358 2.33 8˝ 8˝
24 187 ˝ 187 ˝
18 0.0474 3.08
Roof Deck
ICC-ES APPROVED
16 0.0598 3.88 24˝ Coverage 24˝ Coverage
REFER TO ESR-3818
Composite Deck
20 40 0.911 1.016 0.856 1.014 0.450 0.492 10780 11773 2357 623 1297
18 40 1.274 1.349 1.237 1.349 0.638 0.685 15276 16414 3709 1066 2192
16 40 1.664 1.700 1.647 1.700 0.823 0.865 19702 20730 4649 1658 3378
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers applied in accordance with
SDI white paper ''Perforated Metal Deck Design with Commentary''.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
8 -0 10 -0 11 -0 12 -0 13 -0 14 - 0 15 - 0 16 - 0 18 - 0 20 - 0 (ctr / ctr)
22 85 / 91 54 / 47 45 / 35 38 / 27 32 / 21 - - - - - 12 - 9
20 112 / 117 72 / 60 59 / 45 50 / 35 43 / 27 37 / 22 32 / 18 28 / 15 - - 16 - 4
Single
18 159 / 163 102 / 84 84 / 63 71 / 48 60 / 38 52 / 30 45 / 25 40 / 20 31 / 14 25 / 10 21 - 9
16 205 / 213 131 / 109 109 / 82 91 / 63 78 / 50 67 / 40 58 / 32 51 / 27 41 / 19 33 / 14 26 - 2
22 90 / 256 59 / 131 49 / 98 41 / 76 35 / 60 30 / 48 26 / 39 23 / 32 - - 15 - 7
Form Deck
20 119 / 314 77 / 161 64 / 121 54 / 93 46 / 73 40 / 59 35 / 48 30 / 39 24 / 28 - 19 - 11
Double
18 167 / 416 108 / 213 89 / 160 75 / 123 64 / 97 55 / 78 48 / 63 42 / 52 34 / 37 27 / 27 26 - 3
16 210 / 525 136 / 269 113 / 202 95 / 155 81 / 122 70 / 98 61 / 80 54 / 66 42 / 46 34 / 34 31 - 4
22 102 / 200 73 / 103 60 / 77 51 / 59 44 / 47 38 / 37 33 / 30 - - - 15 - 10
20 146 / 246 95 / 126 79 / 94 67 / 73 57 / 57 49 / 46 43 / 37 - - - 20 - 2
Triple
18 206 / 326 134 / 167 111 / 125 93 / 97 80 / 76 69 / 61 60 / 49 - - - 26 - 8
16 40 6-1 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 19
N-Dek
Table of Contents
16 24˝ Coverage
0.0598 4.13 24˝ Coverage ICC-ES APPROVED
REFER TO ESR-1169
20 40 0.928 1.043 0.868 1.040 0.477 0.563 11413 13484 3585 668 1325
18 40 1.297 1.386 1.253 1.386 0.683 0.752 16356 18023 5620 1131 2232
16 40 1.698 1.747 1.674 1.747 0.887 0.948 21249 22708 7062 1745 3430
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite
8 -0 10 -0 11 -0 12 - 0 13 -0 14 -0 15 - 0 16 - 0 18 - 0 20 - 0 (ctr / ctr)
22 91 / 93 58 / 48 48 / 36 40 / 27 34 / 22 30 / 17 - - - - 13 - 6
20 119 / 119 76 / 61 63 / 46 53 / 35 45 / 28 39 / 22 34 / 18 30 / 15 23 / 10 - 17 - 2
Single
18 170 / 166 109 / 85 90 / 64 76 / 49 65 / 39 56 / 31 48 / 25 43 / 21 34 / 15 27 / 11 22 - 11
16 221 / 217 142 / 111 117 / 84 98 / 64 84 / 51 72 / 41 63 / 33 55 / 27 44 / 19 35 / 14 27 - 6
22 92 / 262 71 / 134 59 / 101 50 / 78 42 / 61 37 / 49 32 / 40 28 / 33 22 / 23 - 16 - 6
Form Deck
16 40 6-2 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
20 www.newmill.com/digital-tools
NA-Dek
Table of Contents
Roof Decks - Type NDA
PROPERTIES
Thickness Cover Weight 2 85 ˝ 2 85 ˝
Gage
(in) (in) (psf)
22 0.0295 1.82 3˝ 3˝
20 0.0358 2.21 8˝ 8˝
0.0474
24
2.92 187 ˝ 187 ˝
18
Roof Deck
16 0.0598 3.68 24˝ Coverage 24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-1169
Composite Deck
20 40 0.867 0.978 0.809 0.975 0.437 0.522 10456 12503 2525 399 807
18 40 1.217 1.301 1.175 1.301 0.631 0.699 15107 16738 3952 752 1507
16 40 1.596 1.640 1.574 1.640 0.822 0.881 19699 21104 4957 1226 2477
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
8 -0 10 -0 11 -0 12 -0 13 -0 14 - 0 15 - 0 16 - 0 18 - 0 20 - 0 (ctr / ctr)
22 62 / 86 50 / 44 44 / 33 37 / 26 31 / 20 - - - - - 12 - 5
20 100 / 111 70 / 57 58 / 43 48 / 33 41 / 26 36 / 21 31 / 17 27 / 14 - - 16 - 0
Single
18 157 / 156 101 / 80 83 / 60 70 / 46 60 / 36 51 / 29 45 / 24 39 / 19 31 / 14 25 / 10 21 - 8
16 205 / 204 131 / 105 109 / 79 91 / 61 78 / 48 67 / 38 58 / 31 51 / 26 41 / 18 33 / 13 26 - 4
22 51 / 246 41 / 126 37 / 95 34 / 73 32 / 57 29 / 46 27 / 37 26 / 31 - - 15 - 2
Form Deck
20 81 / 302 65 / 155 59 / 116 54 / 89 49 / 70 42 / 56 37 / 46 32 / 38 26 / 26 - 19 - 5
Double
18 151 / 402 110 / 206 91 / 154 77 / 119 65 / 94 56 / 75 49 / 61 43 / 50 34 / 35 28 / 26 26 - 3
16 215 / 506 139 / 259 115 / 195 97 / 150 82 / 118 71 / 94 62 / 77 55 / 63 43 / 44 35 / 32 31 - 8
22 58 / 192 47 / 98 42 / 74 39 / 57 36 / 45 33 / 36 31 / 29 - - - 15 - 5
20 92 / 236 73 / 121 67 / 91 61 / 70 56 / 55 52 / 44 46 / 36 - - - 19 - 9
Triple
18 171 / 314 136 / 161 113 / 121 95 / 93 81 / 73 70 / 59 61 / 48 - - - 26 - 7
16 40 6-1 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 21
N-Dek Cellular
Table of Contents
1
18/18 0.0474/0.0474 5.24 24 2 ˝ Coverage ICC-ES APPROVED
REFER TO ESR-1169
20/18 40 1.760 2.037 1.569 1.984 0.552 1.043 13220 24990 3512 668 1325
18/20 40 2.106 2.154 1.972 2.044 0.832 1.281 19926 30686 5505 1131 2232
18/18 40 2.300 2.447 2.148 2.368 0.853 1.350 20432 32325 5505 1131 2232
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite
8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 -0 20 - 0 (ctr / ctr)
20/20 138 / 207 88 / 106 73 / 80 61 / 61 52 / 48 45 / 39 39 / 31 35 / 26 27 / 18 - 18 - 8
20/18 138 / 225 88 / 115 73 / 87 61 / 67 52 / 53 45 / 42 39 / 34 34 / 28 27 / 20 - 18 - 3
Single
18/20 208 / 270 133 / 138 110 / 104 92 / 80 79 / 63 68 / 50 59 / 41 52 / 34 41 / 24 33 / 17 25 - 6
18/18 213 / 295 136 / 151 113 / 113 95 / 87 81 / 69 69 / 55 61 / 45 53 / 37 42 / 26 34 / 19 25 - 6
20/20 133 / 552 106 / 283 96 / 212 88 / 164 82 / 129 76 / 103 70 / 84 61 / 69 49 / 48 39 / 35 22 - 6
Form Deck
18/18 254 / 591 203 / 303 176 / 227 148 / 175 126 / 138 109 / 110 95 / 90 - - - 30 - 10
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information
18/18 40 6-7 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
22 www.newmill.com/digital-tools
N-Dek Cellular
Table of Contents
Roof Decks - Type NDC Cellular
PROPERTIES
Gage Thickness Cover Weight 2 85 ˝ 187 ˝
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 5.81 3˝
16/18 0.0598/0.0474 24.5 6.03
8˝
16/16 0.0598/0.0598 6.61
Roof Deck
1
24 2 ˝ Coverage ICC-ES APPROVED
REFER TO ESR-1169
Composite Deck
16/18 40 2.858 2.858 2.757 2.746 1.176 1.670 28173 39999 6918 1745 3430
16/16 40 3.083 3.184 2.970 3.122 1.201 1.724 28766 41303 6918 1745 3430
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 - 0 18 -0 20 -0 (ctr / ctr)
18/16 217 / 317 139 / 162 115 / 122 97 / 94 82 / 74 71 / 59 62 / 48 54 / 40 43 / 28 35 / 20 25 - 4
Single 16/18 293 / 366 188 / 187 155 / 141 130 / 108 111 / 85 96 / 68 83 / 56 73 / 46 58 / 32 47 / 23 31 - 9
16/16 300 / 395 192 / 202 158 / 152 133 / 117 113 / 92 98 / 74 85 / 60 75 / 49 59 / 35 48 / 25 31 - 6
18/16 223 / 844 179 / 432 162 / 325 149 / 250 129 / 197 112 / 158 98 / 128 86 / 106 68 / 74 55 / 54 30 - 3
Double 16/18 343 / 882 259 / 452 215 / 339 182 / 261 155 / 206 134 / 165 117 / 134 103 / 110 82 / 77 66 / 56 37 - 7
Form Deck
16/16 343 / 983 267 / 503 222 / 378 187 / 291 160 / 229 138 / 183 121 / 149 106 / 123 84 / 86 68 / 63 37 - 4
18/16 254 / 661 203 / 338 180 / 254 151 / 196 129 / 154 111 / 123 97 / 100 - - - 30 - 7
Triple 16/18 390 / 690 293 / 354 243 / 266 204 / 205 174 / 161 150 / 129 130 / 105 - - - 38 - 1
16/16 390 / 769 300 / 394 248 / 296 208 / 228 177 / 179 153 / 144 133 / 117 - - - 37 - 9
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
General Information
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 23
N-Dek Cellular Acoustical
Table of Contents
20/18 40 1.706 2.005 1.524 1.972 0.553 1.043 13249 24975 3512 668 1325
18/20 40 2.036 2.126 1.909 2.043 0.824 1.283 19736 30733 5505 1131 2232
18/18 40 2.225 2.410 2.080 2.357 0.845 1.349 20246 32312 5505 1131 2232
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite
8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 -0 20 - 0 (ctr / ctr)
20/20 139 / 201 89 / 103 73 / 77 62 / 59 53 / 47 45 / 37 39 / 30 35 / 25 27 / 18 - 18 - 9
20/18 138 / 218 88 / 112 73 / 84 61 / 65 52 / 51 45 / 41 39 / 33 35 / 27 27 / 19 - 18 - 5
Single
18/20 206 / 261 132 / 133 109 / 100 91 / 77 78 / 61 67 / 49 58 / 40 51 / 33 41 / 23 33 / 17 25 - 6
18/18 211 / 285 135 / 146 112 / 110 94 / 84 80 / 66 69 / 53 60 / 43 53 / 36 42 / 25 34 / 18 25 - 6
20/20 133 / 545 106 / 279 96 / 209 88 / 161 82 / 127 76 / 102 70 / 83 62 / 68 49 / 48 39 / 35 22 - 8
Form Deck
18/18 254 / 582 203 / 298 174 / 224 146 / 173 125 / 136 108 / 109 94 / 88 - - - 30 - 10
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information
18/18 40 6-6 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
24 www.newmill.com/digital-tools
N-Dek Cellular Acoustical
Table of Contents
Roof Decks - Type NDCA Cellular
PROPERTIES
Gage Thickness Cover Weight 2 85 ˝ 187 ˝
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 5.55 3˝
16/18 0.0598/0.0474 24.5 5.82
16/16 0.0598/0.0598 6.34 8˝
Roof Deck
1 ICC-ES APPROVED
24 2 ˝ Coverage
REFER TO ESR-1169
Composite Deck
16/18 40 2.760 2.808 2.665 2.737 1.165 1.670 27909 39989 6918 1745 3430
16/16 40 2.979 3.127 2.872 3.095 1.190 1.722 28506 41257 6918 1745 3430
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 - 0 18 -0 20 -0 (ctr / ctr)
18/16 215 / 306 138 / 157 114 / 118 96 / 91 82 / 71 70 / 57 61 / 46 54 / 38 43 / 27 34 / 20 25 - 5
Single 16/18 291 / 353 186 / 181 154 / 136 129 / 105 110 / 82 95 / 66 83 / 54 73 / 44 57 / 31 47 / 23 31 - 9
16/16 297 / 381 190 / 195 157 / 147 132 / 113 112 / 89 97 / 71 84 / 58 74 / 48 59 / 33 48 / 24 31 - 7
18/16 223 / 828 179 / 424 162 / 319 149 / 245 129 / 193 112 / 155 97 / 126 86 / 104 68 / 73 55 / 53 30 - 4
Double 16/18 343 / 867 259 / 444 215 / 333 182 / 257 155 / 202 134 / 162 117 / 132 103 / 108 82 / 76 66 / 55 37 - 8
Form Deck
16/16 343 / 966 267 / 494 222 / 371 187 / 286 160 / 225 138 / 180 121 / 146 106 / 121 84 / 85 68 / 62 37 - 5
18/16 254 / 648 203 / 332 178 / 249 150 / 192 127 / 151 110 / 121 96 / 98 - - - 30 - 9
Triple 16/18 390 / 678 291 / 347 240 / 261 202 / 201 172 / 158 148 / 127 129 / 103 - - - 38 - 2
16/16 390 / 756 297 / 387 245 / 291 206 / 224 176 / 176 151 / 141 132 / 115 - - - 37 - 11
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
General Information
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 25
Inverted N-Dek
Table of Contents
8˝ 8˝
16 0.0598 4.13
24˝ Coverage 24˝ Coverage
20 40 1.043 1.043 1.040 0.868 0.563 0.477 13484 11413 3585 668 1325
18 40 1.386 1.386 1.386 1.253 0.752 0.683 18023 16356 5620 1131 2232
16 40 1.747 1.747 1.747 1.674 0.948 0.887 22708 21249 7062 1745 3430
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite
8 -0 10 -0 11 -0 12 - 0 13 -0 14 -0 15 -0 16 -0 18 -0 20 - 0 (ctr / ctr)
22 113 / 109 72 / 56 60 / 42 50 / 32 43 / 25 37 / 20 32 / 17 28 / 14 22 / 10 - 16 - 7
20 140 / 134 90 / 68 74 / 51 62 / 40 53 / 31 46 / 25 40 / 20 35 / 17 28 / 12 - 19 - 11
Single
18 188 / 177 120 / 91 99 / 68 83 / 53 71 / 41 61 / 33 53 / 27 47 / 22 37 / 16 30 / 11 24 - 11
16 237 / 224 151 / 114 125 / 86 105 / 66 90 / 52 77 / 42 67 / 34 59 / 28 47 / 20 38 / 14 29 - 1
22 89 / 262 57 / 134 47 / 101 40 / 78 34 / 61 29 / 49 26 / 40 23 / 33 - - 20 - 3
Form Deck
16 40 6-2 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
26 www.newmill.com/digital-tools
Curve-Dek®
Table of Contents
Roof Decks - Type ND
PROPERTIES
Gage
Thickness2 5 ˝ Cover
8
Weight 2 85 ˝
(in) (in) (psf)
20 0.0358 2.47 3˝ 3˝
24
18 0.0474 3.27
8˝ 8˝
187 ˝ 187 ˝
Roof Deck
24˝ Coverage 24˝ Coverage
• Radii as low as 100'-0"
• Galvanized sheet steel with continuous lengths up to 36'-0".
Composite Deck
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20 40 0.928 1.043 0.868 1.040 0.477 0.563 11413 13484 3585 668 1325
18 40 1.297 1.386 1.253 1.386 0.683 0.752 16356 18023 5620 1131 2232
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Deep-Dek®
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 -0 20 - 0 (ctr / ctr)
20 119 / 119 76 / 61 63 / 46 53 / 35 45 / 28 39 / 22 34 / 18 30 / 15 23 / 10 - 17 - 2
Single
18 170 / 166 109 / 85 90 / 64 76 / 49 65 / 39 56 / 31 48 / 25 43 / 21 34 / 15 27 / 11 22 - 11
20 133 / 322 89 / 165 74 / 124 62 / 95 53 / 75 46 / 60 40 / 49 35 / 40 28 / 28 - 20 - 10
Double
Form Deck
18 185 / 428 119 / 219 99 / 165 83 / 127 71 / 100 61 / 80 53 / 65 47 / 53 37 / 38 30 / 27 27 - 8
20 151 / 252 110 / 129 92 / 97 77 / 75 66 / 59 57 / 47 50 / 38 - - - 21 - 2
Triple
18 230 / 335 148 / 171 123 / 129 103 / 99 88 / 78 76 / 62 66 / 51 - - - 28 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 27
Curve-Dek® Acoustical
Table of Contents
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
8 -0 10 - 0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 - 0 20 - 0 (ctr / ctr)
20 100 / 111 70 / 57 58 / 43 48 / 33 41 / 26 36 / 21 31 / 17 27 / 14 - - 16 - 0
Single
18 157 / 156 101 / 80 83 / 60 70 / 46 60 / 36 51 / 29 45 / 24 39 / 19 31 / 14 25 / 10 21 - 8
20 81 / 302 65 / 155 59 / 116 54 / 89 49 / 70 42 / 56 37 / 46 32 / 38 26 / 26 - 19 - 5
Double
Form Deck
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
Discover the easiest way to specify Steel Roof and Floor Deck:
28 www.newmill.com/digital-tools
Curve-Dek® Cellular
Table of Contents
Roof Decks - Type NDC Cellular
PROPERTIES
Gage Thickness Cover Weight
2 85 ˝ 187 ˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 3.96
3˝
20/18 0.0358/0.0474 4.49
24.5
18/20 0.0474/0.0358 4.70 8˝
Roof Deck
18/18 0.0474/0.0474 5.24 1
24 2 ˝ Coverage
Composite Deck
Fy Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 40 1.619 1.788 1.451 1.703 0.554 1.005 13269 24062 3512 668 1325
20/18 40 1.760 2.037 1.569 1.984 0.552 1.043 13220 24990 3512 668 1325
18/20 40 2.106 2.154 1.972 2.044 0.832 1.281 19926 30686 5505 1131 2232
18/18 40 2.300 2.447 2.148 2.368 0.853 1.350 20432 32325 5505 1131 2232
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Deep-Dek®
Gage Center to Center Span (ft - in)
Condition Span
8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 -0 20 - 0 (ctr / ctr)
20/20 138 / 207 88 / 106 73 / 80 61 / 61 52 / 48 45 / 39 39 / 31 35 / 26 27 / 18 - 18 - 8
20/18 138 / 225 88 / 115 73 / 87 61 / 67 52 / 53 45 / 42 39 / 34 34 / 28 27 / 20 - 18 - 3
Single
18/20 208 / 270 133 / 138 110 / 104 92 / 80 79 / 63 68 / 50 59 / 41 52 / 34 41 / 24 33 / 17 25 - 6
18/18 213 / 295 136 / 151 113 / 113 95 / 87 81 / 69 69 / 55 61 / 45 53 / 37 42 / 26 34 / 19 25 - 6
Form Deck
20/20 133 / 552 106 / 283 96 / 212 88 / 164 82 / 129 76 / 103 70 / 84 61 / 69 49 / 48 39 / 35 22 - 6
20/18 133 / 629 106 / 322 96 / 242 88 / 186 82 / 147 76 / 117 70 / 95 61 / 79 48 / 55 39 / 40 22 - 0
Double
18/20 223 / 665 179 / 340 162 / 256 139 / 197 119 / 155 103 / 124 90 / 101 79 / 83 63 / 58 51 / 43 30 - 6
18/18 223 / 756 179 / 387 162 / 291 147 / 224 125 / 176 108 / 141 95 / 115 83 / 94 66 / 66 53 / 48 30 - 5
20/20 151 / 432 120 / 221 110 / 166 96 / 128 82 / 101 71 / 81 61 / 66 - - - 22 - 9
20/18 151 / 492 120 / 252 110 / 189 96 / 146 81 / 115 70 / 92 61 / 75 - - - 22 - 3
Triple
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 29
Curve-Dek® Cellular Acoustical
Table of Contents
18/20 254 / 514 203 / 263 170 / 198 143 / 152 122 / 120 105 / 96 91 / 78 - - - 30 - 11
18/18 254 / 582 203 / 298 174 / 224 146 / 173 125 / 136 108 / 109 94 / 88 - - - 30 - 10
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
General Information
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
Discover the easiest way to specify Steel Roof and Floor Deck:
30 www.newmill.com/digital-tools
Versa-Dek® 2.0 S ES
Table of Contents
Roof Decks - Type 2.0VSES
PROPERTIES
Gage
Thickness Cover Weight 483 ˝ 6˝
(in) (in) (psf)
20 0.0358 2.70
2˝
18 0.0474 24 3.56
5
16 0.0598 4.49 8˝
Roof Deck
24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657
Composite Deck
20 40 0.511 0.511 0.511 0.437 0.390 0.346 9330 8292 3519 933 1827
18 40 0.674 0.674 0.674 0.627 0.514 0.475 12319 11374 4617 1561 3047
16 40 0.848 0.848 0.848 0.828 0.646 0.615 15481 14725 5769 2390 4654
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Deep-Dek®
Gage Center to Center Span (ft - in)
Condition Span
6 -0 6 -6 7 -0 7 -6 8 -0 9 -0 10 - 0 11 -0 12 -0 13 -0 (ctr / ctr)
20 173 / 155 147 / 122 127 / 98 111 / 79 97 / 65 77 / 46 62 / 33 51 / 25 43 / 19 37 / 15 14 - 2
Single 18 228 / 205 194 / 161 168 / 129 146 / 105 128 / 86 101 / 61 82 / 44 68 / 33 57 / 26 49 / 20 17 - 8
16 287 / 257 244 / 202 211 / 162 183 / 132 161 / 109 127 / 76 103 / 56 85 / 42 72 / 32 61 / 25 20 - 10
20 152 / 374 129 / 294 112 / 235 97 / 191 86 / 158 68 / 111 55 / 81 46 / 61 38 / 47 33 / 37 17 - 3
Form Deck
Double 18 208 / 494 177 / 388 153 / 311 134 / 253 118 / 208 93 / 146 75 / 107 62 / 80 52 / 62 45 / 49 21 - 5
16 269 / 621 229 / 488 198 / 391 173 / 318 152 / 262 120 / 184 98 / 134 81 / 101 68 / 78 58 / 61 25 - 1
20 188 / 293 161 / 230 139 / 184 121 / 150 107 / 123 85 / 87 69 / 63 57 / 47 48 / 37 41 / 29 17 - 5
Triple 18 258 / 386 220 / 304 191 / 243 166 / 198 146 / 163 116 / 114 94 / 83 78 / 63 65 / 48 56 / 38 21 - 8
16 333 / 486 285 / 382 246 / 306 215 / 249 189 / 205 150 / 144 122 / 105 101 / 79 85 / 61 72 / 48 25 - 5
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
General Information
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 31
Versa-Dek® 2.0 S ES Acoustical
Table of Contents
Gage
Thickness Cover Weight 483 ˝ 6˝
(in) (in) (psf)
20 0.0358 2.51
2˝
18 0.0474 24 3.32
5
16 0.0598 4.18 8˝
Roof Deck
24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657
20 40 0.483 0.483 0.483 0.427 0.383 0.345 9178 8268 3519 933 1827
18 40 0.637 0.637 0.637 0.607 0.506 0.473 12118 11327 4617 1561 3047
16 40 0.802 0.802 0.802 0.794 0.636 0.612 15227 14668 5769 2390 4654
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite
Constr.
Gage Center to Center Span (ft - in)
Condition Span
6 -0 6 -6 7 -0 7 -6 8 -0 9 -0 10 - 0 11 -0 12 -0 13 -0 (ctr / ctr)
20 170 / 147 145 / 115 125 / 92 109 / 75 96 / 62 76 / 43 61 / 32 51 / 24 42 / 18 36 / 14 14 - 0
Single 18 224 / 193 191 / 152 165 / 122 144 / 99 126 / 82 100 / 57 81 / 42 67 / 31 56 / 24 48 / 19 17 - 7
16 282 / 243 240 / 191 207 / 153 180 / 125 159 / 103 125 / 72 102 / 53 84 / 39 70 / 30 60 / 24 20 - 10
20 151 / 353 129 / 278 111 / 223 97 / 181 85 / 149 68 / 105 55 / 76 45 / 57 38 / 44 33 / 35 17 - 1
Form Deck
Double 18 207 / 467 177 / 367 152 / 294 133 / 239 117 / 197 93 / 138 75 / 101 62 / 76 52 / 58 45 / 46 21 - 3
16 267 / 587 228 / 461 197 / 369 172 / 300 151 / 247 120 / 174 97 / 127 80 / 95 68 / 73 58 / 58 25 - 0
20 188 / 277 160 / 218 139 / 174 121 / 142 107 / 117 84 / 82 68 / 60 57 / 45 48 / 35 41 / 27 17 - 4
Triple 18 257 / 365 220 / 287 190 / 230 166 / 187 146 / 154 115 / 108 94 / 79 78 / 59 65 / 46 56 / 36 21 - 7
16 332 / 459 284 / 361 245 / 289 214 / 235 189 / 194 149 / 136 121 / 99 100 / 75 84 / 57 72 / 45 25 - 4
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
Typical Fastener Layouts
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
32 www.newmill.com/digital-tools
Versa-Dek® 2.0 LS ES
Table of Contents
Roof Decks - Type 2.0VLSES
PROPERTIES
Gage
Thickness Cover Weight 483 ˝ 6
(in) (in) (psf)
22 0.0295 2.25
2˝
20 0.0358 2.72
24 5
18 0.0474 3.60 8˝
Roof Deck
16 0.0598 4.53 24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657
Composite Deck
20 40 0.506 0.506 0.505 0.506 0.386 0.379 9246 9074 3519 933 1827
18 40 0.667 0.667 0.667 0.667 0.510 0.507 12207 12135 4617 1561 3047
16 40 0.838 0.838 0.838 0.838 0.640 0.640 15339 15339 5769 2390 4654
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
6 -0 6 -6 7 -0 7 -6 8 -0 9 -0 10 -0 11 -0 12 -0 13 - 0 (ctr / ctr)
22 135 / 127 115 / 100 99 / 80 86 / 65 76 / 53 60 / 38 49 / 27 40 / 21 34 / 16 - 11 - 4
20 171 / 153 146 / 121 126 / 97 110 / 79 96 / 65 76 / 45 62 / 33 51 / 25 43 / 19 36 / 15 14 - 0
Single
18 226 / 202 193 / 159 166 / 127 145 / 104 127 / 85 100 / 60 81 / 44 67 / 33 57 / 25 48 / 20 17 - 6
16 284 / 254 242 / 200 209 / 160 182 / 130 160 / 107 126 / 75 102 / 55 85 / 41 71 / 32 61 / 25 20 - 8
22 135 / 305 115 / 240 100 / 192 87 / 156 76 / 129 60 / 90 49 / 66 41 / 50 34 / 38 29 / 30 13 - 11
Form Deck
20 165 / 370 141 / 291 122 / 233 106 / 190 94 / 156 74 / 110 60 / 80 50 / 60 42 / 46 36 / 36 17 - 1
Double
18 221 / 488 189 / 384 163 / 307 142 / 250 125 / 206 99 / 145 80 / 105 67 / 79 56 / 61 48 / 48 21 - 2
16 279 / 613 239 / 483 206 / 386 180 / 314 158 / 259 125 / 182 102 / 133 84 / 100 71 / 77 60 / 60 24 - 10
22 168 / 239 143 / 188 124 / 150 108 / 122 95 / 101 75 / 71 61 / 52 51 / 39 43 / 30 36 / 23 14 - 1
20 205 / 290 176 / 228 152 / 182 132 / 148 117 / 122 92 / 86 75 / 63 62 / 47 52 / 36 45 / 28 17 - 4
Triple
18 274 / 382 235 / 300 203 / 241 177 / 196 156 / 161 124 / 113 100 / 82 83 / 62 70 / 48 60 / 38 21 - 6
16 40 4-8 4-5 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 33
2˝
5
8˝
24˝ Coverage
Roof Decks - Type 2.0VLSESA
PROPERTIES
Thickness Cover Weight 483 ˝
Gage 6
(in) (in) (psf)
22 0.0295 2.08
2˝
20 0.0358 2.53
24 5
18 0.0474 3.34 8˝
Roof Deck
20 40 0.476 0.476 0.476 0.476 0.379 0.377 9075 9027 3519 933 1827
18 40 0.628 0.628 0.628 0.628 0.500 0.500 11981 11981 4617 1561 3047
16 40 0.789 0.789 0.789 0.789 0.629 0.629 15054 15054 5769 2390 4654
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite
6 -0 6 -6 7 -0 7 -6 8 -0 9 -0 10 - 0 11 -0 12 -0 13 - 0 (ctr / ctr)
22 132 / 119 113 / 94 97 / 75 85 / 61 74 / 50 59 / 35 48 / 26 39 / 19 33 / 15 - 11 - 2
20 168 / 144 143 / 114 123 / 91 108 / 74 95 / 61 75 / 43 60 / 31 50 / 23 42 / 18 36 / 14 13 - 10
Single
18 222 / 191 189 / 150 163 / 120 142 / 98 125 / 80 99 / 56 80 / 41 66 / 31 55 / 24 47 / 19 17 - 5
16 279 / 240 238 / 188 205 / 151 178 / 123 157 / 101 124 / 71 100 / 52 83 / 39 70 / 30 59 / 24 20 - 7
22 134 / 287 115 / 226 99 / 181 87 / 147 76 / 121 60 / 85 49 / 62 40 / 47 34 / 36 29 / 28 13 - 8
Form Deck
20 165 / 348 141 / 274 121 / 219 106 / 178 93 / 147 74 / 103 60 / 75 50 / 56 42 / 44 35 / 34 16 - 11
Double
18 218 / 459 186 / 361 161 / 289 141 / 235 124 / 194 98 / 136 79 / 99 66 / 75 55 / 57 47 / 45 21 - 1
16 274 / 578 234 / 454 202 / 364 177 / 296 155 / 244 123 / 171 100 / 125 83 / 94 69 / 72 59 / 57 24 - 9
22 167 / 225 143 / 177 123 / 142 108 / 115 95 / 95 75 / 67 61 / 49 50 / 36 42 / 28 36 / 22 13 - 11
20 204 / 272 175 / 214 151 / 172 132 / 139 116 / 115 92 / 81 75 / 59 62 / 44 52 / 34 44 / 27 17 - 1
Triple
18 271 / 360 232 / 283 200 / 226 175 / 184 154 / 152 122 / 107 99 / 78 82 / 58 69 / 45 59 / 35 21 - 4
Typical Fastener Layouts
16 341 / 452 291 / 356 252 / 285 220 / 231 193 / 191 153 / 134 124 / 98 103 / 73 87 / 57 74 / 44 25 - 1
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information
16 40 4-8 4-4 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
34 www.newmill.com/digital-tools
Versa-Dek® 3.5 LS
Table of Contents
Roof Decks - Type 3.5VLS
PROPERTIES
Thickness Cover Weight 8˝ 443 ˝
Gage
(in) (in) (psf)
20 0.0358 3.33
3 21 ˝
19 0.0418 3.88
24
18 0.0474 4.40 3
Roof Deck
4˝
16 0.0598 5.54
24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657
Composite Deck
19 40 2.324 2.324 2.296 2.129 0.946 1.072 22653 25665 4613 833 1744
18 40 2.664 2.664 2.648 2.475 1.113 1.226 26662 29365 5931 1055 2194
16 40 3.394 3.394 3.394 3.262 1.504 1.573 36031 37687 8289 1631 3355
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 -0 20 -0 22 -0 (ctr / ctr)
20 124 / 128 102 / 96 86 / 74 73 / 58 63 / 47 55 / 38 48 / 31 38 / 22 31 / 16 26 / 12 25 - 6
19 151 / 152 125 / 114 105 / 88 89 / 69 77 / 56 67 / 45 59 / 37 47 / 26 38 / 19 31 / 14 29 - 4
Single
18 178 / 175 147 / 131 123 / 101 105 / 79 91 / 64 79 / 52 69 / 43 55 / 30 44 / 22 37 / 16 32 - 8
16 240 / 223 199 / 167 167 / 129 142 / 101 123 / 81 107 / 66 94 / 54 74 / 38 60 / 28 50 / 21 38 - 11
20 105 / 310 96 / 233 88 / 179 81 / 141 73 / 113 64 / 92 56 / 76 44 / 53 36 / 39 - 30 - 8
Form Deck
19 140 / 367 127 / 276 116 / 213 100 / 167 86 / 134 75 / 109 66 / 90 52 / 63 42 / 46 - 35 - 2
Double
18 176 / 421 159 / 316 134 / 244 114 / 192 99 / 153 86 / 125 76 / 103 60 / 72 49 / 53 - 38 - 11
16 247 / 537 205 / 403 172 / 311 147 / 244 127 / 196 111 / 159 97 / 131 77 / 92 63 / 67 - 40 - 0
20 119 / 242 109 / 182 100 / 140 92 / 110 85 / 88 79 / 72 - - - - 31 - 1
19 159 / 288 144 / 216 132 / 166 122 / 131 107 / 105 93 / 85 - - - - 35 - 7
Triple
18 199 / 330 181 / 248 166 / 191 142 / 150 123 / 120 107 / 98 - - - - 39 - 5
16 40 8-9 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 35
Versa-Dek® 3.5 LS Acoustical
Table of Contents
3
16 0.0598 5.12 4˝
24˝ Coverage ICC-ES APPROVED
REFER TO ESR-2657
19 40 2.139 2.139 2.113 2.089 0.921 1.072 22061 25673 4613 833 1744
18 40 2.450 2.450 2.436 2.418 1.084 1.224 25970 29327 5931 1055 2194
16 40 3.122 3.123 3.122 3.123 1.466 1.564 35113 37461 8289 1631 3355
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite
10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 -0 20 -0 22 -0 (ctr / ctr)
20 120 / 118 100 / 89 84 / 68 71 / 54 61 / 43 54 / 35 47 / 29 37 / 20 30 / 15 25 / 11 25 - 2
19 147 / 140 122 / 105 102 / 81 87 / 64 75 / 51 65 / 42 57 / 34 45 / 24 37 / 18 30 / 13 29 - 1
Single
18 173 / 161 143 / 121 120 / 93 102 / 73 88 / 59 77 / 48 68 / 39 53 / 28 43 / 20 36 / 15 32 - 6
16 234 / 205 193 / 154 163 / 118 139 / 93 119 / 75 104 / 61 91 / 50 72 / 35 59 / 26 48 / 19 39 - 0
20 105 / 285 96 / 214 88 / 165 81 / 130 73 / 104 64 / 84 56 / 70 44 / 49 36 / 36 - 30 - 4
Form Deck
19 140 / 338 127 / 254 116 / 196 100 / 154 86 / 123 75 / 100 66 / 83 52 / 58 43 / 42 - 34 - 11
Double
18 176 / 387 159 / 291 134 / 224 114 / 176 99 / 141 86 / 115 76 / 95 60 / 66 49 / 48 - 38 - 10
16 245 / 494 203 / 371 171 / 286 146 / 225 126 / 180 110 / 146 97 / 121 77 / 85 62 / 62 - 40 - 0
20 119 / 223 109 / 168 100 / 129 92 / 102 85 / 81 79 / 66 - - - - 30 - 9
19 159 / 265 144 / 199 132 / 153 122 / 120 107 / 96 93 / 78 - - - - 35 - 4
Triple
18 199 / 303 181 / 228 166 / 175 142 / 138 123 / 110 107 / 90 - - - - 39 - 4
Typical Fastener Layouts
16 304 / 386 253 / 290 213 / 224 182 / 176 157 / 141 137 / 114 - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information
16 40 7-3 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
36 www.newmill.com/digital-tools
Super Versa-Dek® 6.5 LS
Table of Contents
Roof Decks - Type 6.5SVLS
PROPERTIES 8˝
2 85 ˝
Thickness Cover Weight
Gage
(in) (in) (psf)
20/20 0.0358/0.0358 5.81
6 21 ˝
18/18 0.0474/0.0474 24 7.70
16/16 0.0598/0.0598 9.72
Roof Deck
3
4˝
24˝ Coverage
Composite Deck
20/20 40 8.183 8.655 7.320 8.028 1.581 2.068 37876 49536 3383 681 1437
18/18 40 11.605 12.048 10.811 11.476 2.489 2.993 59619 71684 5931 1151 2390
16/16 40 15.239 15.887 14.486 15.458 3.564 4.138 85367 99113 8289 1771 3638
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 2" for end bearing and 4" for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Deep-Dek®
Gage Center to Center Span (ft - in)
Condition Span
15 -0 16 - 0 17 - 0 18 - 0 20 -0 22 -0 24 -0 26 -0 28 -0 30 -0 (ctr / ctr)
20/20 91 / 159 85 / 131 80 / 109 76 / 92 63 / 67 52 / 50 44 / 39 37 / 31 32 / 24 28 / 20 39 - 11
Single 18/18 153 / 225 144 / 186 135 / 155 123 / 130 99 / 95 82 / 71 69 / 55 59 / 43 51 / 35 44 / 28 40 - 0
16/16 236 / 296 221 / 244 197 / 203 176 / 171 142 / 125 118 / 94 99 / 72 84 / 57 73 / 46 63 / 37 40 - 0
Form Deck
Double
Triple
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
General Information
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 37
Super Versa-Dek® 6.5 LS Acoustical
Table of Contents
3
4˝
24˝ Coverage
20/20 40 7.618 8.518 6.856 8.206 1.552 2.105 37167 50423 3383 681 1437
18/18 40 10.787 11.785 10.090 11.586 2.435 3.056 58319 73206 5931 1151 2390
16/16 40 14.164 15.238 13.510 15.120 3.478 4.171 83315 99907 8289 1771 3638
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 2" for end bearing and 4" for interior bearing.
Deep-Dek®
Long-Span Composite
Double
Triple
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
Typical Fastener Layouts
Discover the easiest way to specify Steel Roof and Floor Deck:
38 www.newmill.com/digital-tools
Deep-Dek® 4.5
Table of Contents
Roof Decks - Type 4.5D
PROPERTIES
Thickness Cover Weight 7 87 ˝
Gage
(in) (in) (psf)
20 0.0358 3.09
18 0.0474 4.09 4 85˝
12
16 0.0598 5.16
Roof Deck
14 0.0747 6.44 12˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657
Composite Deck
18 40 3.832 3.939 3.778 3.939 1.491 1.596 35724 38237 4224 990 1925
16 40 4.963 4.963 4.963 4.963 1.972 2.011 47234 48168 6723 1518 2917
14 40 6.191 6.191 6.191 6.191 2.507 2.507 60060 60060 9675 2279 4341
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 - 0 20 - 0 22 -0 (ctr / ctr)
20 118 / 179 107 / 135 98 / 104 90 / 82 80 / 65 70 / 53 61 / 44 48 / 31 39 / 22 32 / 17 31 - 6
18 198 / 251 180 / 189 165 / 145 141 / 114 122 / 92 106 / 74 93 / 61 74 / 43 60 / 31 49 / 24 40 - 0
Single
16 304 / 325 260 / 244 219 / 188 186 / 148 161 / 119 140 / 96 123 / 79 97 / 56 79 / 41 65 / 31 40 - 0
14 400 / 406 331 / 305 278 / 235 237 / 185 204 / 148 178 / 120 156 / 99 124 / 70 100 / 51 83 / 38 40 - 0
20 93 / 471 85 / 354 78 / 272 72 / 214 67 / 172 62 / 139 58 / 115 52 / 81 46 / 59 - 37 - 10
Form Deck
18 154 / 623 140 / 468 128 / 360 118 / 283 110 / 227 103 / 184 96 / 152 77 / 107 63 / 78 - 40 - 0
Double
16 233 / 785 212 / 589 194 / 454 179 / 357 160 / 286 140 / 232 123 / 192 98 / 135 79 / 98 - 40 - 0
14 347 / 979 316 / 735 272 / 566 232 / 445 201 / 357 175 / 290 154 / 239 122 / 168 99 / 122 - 40 - 0
20 106 / 368 96 / 277 88 / 213 81 / 168 76 / 134 71 / 109 - - - - 38 - 4
18 175 / 487 159 / 366 146 / 282 135 / 222 125 / 178 117 / 144 - - - - 40 - 0
Triple
16 265 / 614 241 / 461 221 / 355 204 / 279 189 / 224 174 / 182 - - - - 40 - 0
14 40 9-7 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 39
Deep-Dek® 4.5 Acoustical
Table of Contents
18 40 3.586 3.690 3.533 3.690 1.385 1.491 33170 35704 2874 990 1391
16 40 4.652 4.652 4.652 4.652 1.840 1.879 44064 44996 4568 1518 2099
14 40 5.806 5.806 5.806 5.806 2.344 2.344 56135 56135 6564 2279 3113
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite
10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 - 0 20 -0 22 -0 (ctr / ctr)
20 118 / 167 107 / 125 98 / 97 85 / 76 74 / 61 64 / 49 56 / 41 45 / 29 36 / 21 30 / 16 29 - 7
18 198 / 235 180 / 177 154 / 136 131 / 107 113 / 86 98 / 70 86 / 57 68 / 40 55 / 29 46 / 22 39 - 10
Single
16 294 / 305 243 / 229 204 / 176 174 / 139 150 / 111 131 / 90 115 / 74 91 / 52 73 / 38 61 / 29 40 - 0
14 374 / 381 309 / 286 260 / 220 221 / 173 191 / 139 166 / 113 146 / 93 116 / 65 94 / 48 77 / 36 40 - 0
20 68 / 441 61 / 331 56 / 255 52 / 201 48 / 161 45 / 131 42 / 108 38 / 76 34 / 55 - 35 - 7
Form Deck
18 111 / 583 101 / 438 93 / 338 86 / 265 79 / 213 74 / 173 70 / 142 62 / 100 56 / 73 - 40 - 0
Double
16 168 / 735 153 / 552 140 / 426 129 / 335 120 / 268 112 / 218 105 / 180 90 / 126 73 / 92 - 40 - 0
14 249 / 918 226 / 690 208 / 531 192 / 418 178 / 334 162 / 272 143 / 224 113 / 157 92 / 115 - 40 - 0
20 77 / 345 70 / 259 64 / 200 59 / 157 55 / 126 51 / 102 - - - - 36 - 1
18 126 / 456 115 / 343 105 / 264 97 / 208 90 / 166 84 / 135 - - - - 40 - 0
Triple
16 191 / 575 173 / 432 159 / 333 147 / 262 136 / 210 127 / 171 - - - - 40 - 0
Typical Fastener Layouts
14 283 / 718 257 / 540 236 / 416 218 / 327 202 / 262 189 / 213 - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information
14 40 9-6 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
40 www.newmill.com/digital-tools
Deep-Dek® 6.0
Table of Contents
Roof Decks - Type 6.0D
PROPERTIES
Thickness Cover Weight 7 87 ˝
Gage
(in) (in) (psf)
20 0.0358 3.44
18 0.0474 4.55 6 81˝
12
16 0.0598 5.74
Roof Deck
14 0.0747 7.16
12˝ Coverage ICC-ES APPROVED
REFER TO ESR-2657
Composite Deck
18 40 7.395 7.601 7.292 7.601 2.172 2.358 52033 56485 3235 940 1913
16 40 9.579 9.579 9.579 9.579 2.915 2.971 69827 71160 6510 1452 2900
14 40 11.950 11.950 11.950 11.950 3.705 3.705 88739 88739 10491 2193 4319
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
14 -0 15 -0 16 -0 17 -0 18 -0 19 -0 20 -0 22 - 0 24 -0 26 -0 (ctr / ctr)
20 79 / 127 74 / 103 69 / 85 65 / 71 61 / 60 58 / 51 55 / 43 45 / 33 38 / 25 32 / 20 40 - 0
18 134 / 177 125 / 144 118 / 118 111 / 99 104 / 83 96 / 71 87 / 61 72 / 46 60 / 35 51 / 28 40 - 0
Single
16 207 / 229 194 / 186 181 / 153 161 / 128 144 / 108 129 / 92 116 / 78 96 / 59 81 / 45 69 / 36 40 - 0
14 302 / 285 263 / 232 231 / 191 205 / 159 183 / 134 164 / 114 148 / 98 122 / 74 103 / 57 88 / 45 40 - 0
20 66 / 327 62 / 265 58 / 219 54 / 182 51 / 154 49 / 131 46 / 112 - - - 40 - 0
Form Deck
18 109 / 438 102 / 356 96 / 293 90 / 245 85 / 206 81 / 175 77 / 150 - - - 40 - 0
Double
16 166 / 552 155 / 449 145 / 370 136 / 308 129 / 260 122 / 221 116 / 189 - - - 40 - 0
14 247 / 688 230 / 560 216 / 461 200 / 384 179 / 324 161 / 275 146 / 236 - - - 40 - 0
20 75 / 256 70 / 208 - - - - - - - - 40 - 0
18 124 / 343 116 / 279 - - - - - - - - 40 - 0
Triple
16 188 / 432 176 / 351 - - - - - - - - 40 - 0
14 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 41
Deep-Dek® 6.0 Acoustical
Table of Contents
14 0.0747 6.71
12˝ Coverage 12˝ Coverage ICC-ES APPROVED
REFER TO ESR-2657
18 40 6.781 6.983 6.680 6.983 1.972 2.159 47242 51720 2172 863 1387
16 40 8.804 8.804 8.804 8.804 2.665 2.721 63836 65185 4365 1438 2094
14 40 10.989 10.989 10.989 10.989 3.395 3.395 81328 81328 7026 2193 3107
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite
14 -0 15 -0 16 -0 17 -0 18 - 0 19 - 0 20 - 0 22 - 0 24 -0 26 -0 (ctr / ctr)
20 66 / 116 61 / 94 57 / 77 54 / 65 51 / 54 48 / 46 46 / 40 39 / 30 33 / 23 28 / 18 36 - 9
18 123 / 162 115 / 132 108 / 109 102 / 90 96 / 76 87 / 65 79 / 56 65 / 42 55 / 32 47 / 25 40 - 0
Single
16 205 / 210 189 / 171 166 / 141 147 / 117 131 / 99 118 / 84 106 / 72 88 / 54 74 / 42 63 / 33 40 - 0
14 277 / 263 241 / 213 212 / 176 188 / 147 167 / 124 150 / 105 136 / 90 112 / 68 94 / 52 80 / 41 40 - 0
20 48 / 299 45 / 243 42 / 200 40 / 167 37 / 141 36 / 120 34 / 103 - - - 40 - 0
Form Deck
14 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
42 www.newmill.com/digital-tools
Deep-Dek® 7.5
Table of Contents
Roof Decks - Type 7.5D
PROPERTIES
7 87 ˝
Thickness Cover Weight
Gage
(in) (in) (psf)
20 0.0358 3.79
18 0.0474 5.01 7 85 ˝
12
16 0.0598 6.32
Roof Deck
14 0.0747 7.89
12˝ Coverage ICC-ES APPROVED
REFER TO ESR-2657
Composite Deck
18 40 12.357 12.510 12.191 12.420 2.909 3.049 69680 73035 2575 896 1902
16 40 15.992 15.992 15.992 15.992 3.936 4.009 94274 96035 5178 1394 2886
14 40 19.952 19.952 19.952 19.952 5.000 5.000 119769 119769 10113 2117 4300
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
15 -0 16 -0 17 -0 18 -0 20 -0 22 - 0 24 - 0 26 -0 28 -0 30 -0 (ctr / ctr)
20 69 / 171 65 / 141 61 / 118 58 / 99 52 / 72 47 / 54 43 / 42 40 / 33 35 / 26 30 / 21 40 - 0
18 120 / 240 112 / 198 105 / 165 100 / 139 90 / 101 81 / 76 75 / 59 69 / 46 59 / 37 52 / 30 40 - 0
Single
16 186 / 311 174 / 256 164 / 213 155 / 180 139 / 131 127 / 98 109 / 76 93 / 60 80 / 48 70 / 39 40 - 0
14 282 / 388 265 / 319 249 / 266 235 / 224 200 / 163 165 / 123 139 / 95 118 / 74 102 / 60 89 / 48 40 - 0
20 61 / 435 57 / 358 54 / 299 51 / 252 46 / 183 - - - - - 40 - 0
Form Deck
18 101 / 586 95 / 483 90 / 402 85 / 339 76 / 247 - - - - - 40 - 0
Double
16 154 / 749 144 / 617 136 / 515 128 / 433 115 / 316 - - - - - 40 - 0
14 229 / 934 215 / 770 202 / 642 191 / 541 172 / 394 - - - - - 40 - 0
20 70 / 340 - - - - - - - - - 40 - 0
18 115 / 459 - - - - - - - - - 40 - 0
Triple
16 175 / 586 - - - - - - - - - 40 - 0
14 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 43
Deep-Dek® 7.5 Acoustical
Table of Contents
14 0.0747 7.31
12˝ Coverage 12˝ Coverage ICC-ES APPROVED
REFER TO ESR-2657
18 40 11.122 11.238 10.959 11.132 2.528 2.710 60556 64914 1714 807 1385
16 40 14.434 14.434 14.434 14.434 3.531 3.606 84580 86380 3445 1360 2091
14 40 18.017 18.017 18.017 18.017 4.500 4.500 107778 107778 6720 2117 3103
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite
15 -0 16 -0 17 - 0 18 - 0 20 - 0 22 - 0 24 - 0 26 -0 28 -0 30 -0 (ctr / ctr)
20 56 / 152 53 / 125 50 / 104 47 / 88 42 / 64 38 / 48 35 / 37 32 / 29 29 / 23 26 / 19 40 - 0
18 108 / 216 101 / 178 95 / 148 90 / 125 81 / 91 73 / 68 67 / 53 60 / 41 51 / 33 45 / 27 40 - 0
Single
16 181 / 280 170 / 231 160 / 193 151 / 162 136 / 118 117 / 89 98 / 68 83 / 54 72 / 43 63 / 35 40 - 0
14 296 / 350 277 / 288 249 / 240 222 / 203 180 / 148 148 / 111 125 / 85 106 / 67 92 / 54 80 / 44 40 - 0
20 45 / 389 42 / 320 40 / 267 37 / 225 34 / 164 - - - - - 40 - 0
Form Deck
14 188 / 660 - - - - - - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information
14 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
44 www.newmill.com/digital-tools
Deep-Dek® 4.5 Cellular
Table of Contents
Roof Decks - Type 4.5DC Cellular
PROPERTIES
Gage Thickness Cover Weight 7 87 ˝ 12˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 4.47
20/18 0.0358/0.0474 5.05 4 58 ˝
24
18/20 0.0474/0.0358 5.35
Roof Deck
18/18 0.0474/0.0474 5.92 24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657
Composite Deck
20/18 40 4.634 4.839 4.322 4.628 1.054 1.603 25237 38391 1871 588 1164
18/20 40 5.750 5.750 5.638 4.995 1.728 2.008 41388 48085 4224 990 1925
18/18 40 6.210 6.210 6.085 5.626 1.727 2.076 41361 49716 4224 990 1925
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
11 -0 12 -0 13 -0 14 -0 15 -0 16 - 0 18 -0 20 -0 22 -0 24 -0 (ctr / ctr)
20/20 107 / 214 98 / 165 90 / 130 84 / 104 75 / 84 66 / 70 52 / 49 42 / 36 35 / 27 29 / 21 31 - 1
20/18 107 / 228 98 / 176 90 / 138 84 / 111 75 / 90 66 / 74 52 / 52 42 / 38 35 / 29 29 / 22 30 - 4
Single
18/20 180 / 283 165 / 218 152 / 172 141 / 137 123 / 112 108 / 92 85 / 65 69 / 47 57 / 35 48 / 27 40 - 0
18/18 180 / 306 165 / 236 152 / 185 141 / 148 123 / 121 108 / 99 85 / 70 69 / 51 57 / 38 48 / 29 40 - 0
20/20 85 / 516 78 / 397 72 / 312 67 / 250 62 / 203 58 / 168 52 / 118 47 / 86 - - 37 - 1
Form Deck
20/18 85 / 575 78 / 443 72 / 348 67 / 279 62 / 227 58 / 187 52 / 131 47 / 96 - - 36 - 2
Double
18/20 140 / 683 128 / 526 118 / 414 110 / 331 103 / 269 96 / 222 86 / 156 77 / 114 - - 40 - 0
18/18 140 / 737 128 / 568 118 / 447 110 / 358 103 / 291 96 / 240 86 / 168 77 / 123 - - 40 - 0
20/20 96 / 404 88 / 311 81 / 245 76 / 196 71 / 159 - - - - - 37 - 7
20/18 96 / 450 88 / 346 81 / 272 76 / 218 71 / 177 - - - - - 36 - 7
Triple
18/20 159 / 534 146 / 412 135 / 324 125 / 259 117 / 211 - - - - - 40 - 0
18/18 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 45
Deep-Dek® 4.5 Cellular
Table of Contents
16/18 40 7.655 7.655 7.655 6.647 2.449 2.574 58649 61648 6723 1518 2917
16/16 40 8.180 8.180 8.180 7.378 2.493 2.651 59718 63494 6723 1518 2917
14/16 40 9.619 9.619 9.619 8.638 3.353 3.254 80304 77933 9675 2279 4341
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite
13 -0 14 -0 15 -0 16 -0 17 -0 18 -0 20 -0 22 - 0 24 -0 26 -0 (ctr / ctr)
18/16 152 / 198 141 / 158 122 / 129 108 / 106 95 / 88 85 / 75 69 / 54 57 / 41 48 / 31 41 / 25 40 - 0
16/18 231 / 228 199 / 183 174 / 149 153 / 123 135 / 102 121 / 86 98 / 63 81 / 47 68 / 36 58 / 29 40 - 0
Single
16/16 233 / 244 203 / 195 177 / 159 156 / 131 138 / 109 123 / 92 100 / 67 82 / 50 69 / 39 59 / 31 40 - 0
14/16 317 / 287 273 / 230 238 / 187 209 / 154 185 / 128 165 / 108 134 / 79 111 / 59 93 / 46 79 / 36 40 - 0
18/16 118 / 477 110 / 382 103 / 310 96 / 256 91 / 213 86 / 180 77 / 131 - - - 40 - 0
Form Deck
16/18 179 / 551 167 / 441 156 / 359 146 / 295 137 / 246 124 / 207 101 / 151 - - - 40 - 0
Double
16/16 179 / 589 167 / 471 156 / 383 146 / 316 137 / 263 128 / 222 104 / 162 - - - 40 - 0
14/16 267 / 692 248 / 554 225 / 451 199 / 371 176 / 309 158 / 261 128 / 190 - - - 40 - 0
18/16 135 / 373 125 / 299 117 / 243 - - - - - - - 40 - 0
16/18 204 / 431 189 / 345 177 / 281 - - - - - - - 40 - 0
Triple
16/16 204 / 461 189 / 369 177 / 300 - - - - - - - 40 - 0
Typical Fastener Layouts
14/16 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
46 www.newmill.com/digital-tools
Deep-Dek® 4.5 Cellular Acoustical
Table of Contents
Roof Decks - Type 4.5DCA Cellular
PROPERTIES
Gage Thickness Cover Weight 7 87 ˝ 12˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 4.32
20/18 0.0358/0.0474
24
4.84 4 58 ˝
18/20 0.0474/0.0358 5.19
Roof Deck
18/18 0.0474/0.0474 5.72
24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657
Composite Deck
20/18 40 4.528 4.787 4.235 4.624 1.053 1.603 25222 38384 1871 588 1164
18/20 40 5.597 5.597 5.490 4.998 1.723 2.008 41279 48097 4224 990 1925
18/18 40 6.040 6.040 5.920 5.623 1.728 2.075 41378 49711 4224 990 1925
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
11 -0 12 -0 13 -0 14 -0 15 -0 16 - 0 18 -0 20 -0 22 -0 24 -0 (ctr / ctr)
20/20 107 / 209 98 / 161 90 / 127 84 / 101 75 / 82 66 / 68 52 / 48 42 / 35 35 / 26 29 / 20 31 - 4
20/18 107 / 223 98 / 172 90 / 135 84 / 108 75 / 88 66 / 72 52 / 51 42 / 37 35 / 28 29 / 21 30 - 7
Single
18/20 180 / 276 165 / 212 152 / 167 140 / 134 122 / 109 107 / 90 85 / 63 69 / 46 57 / 34 48 / 27 40 - 0
18/18 180 / 297 165 / 229 152 / 180 141 / 144 123 / 117 108 / 97 85 / 68 69 / 49 57 / 37 48 / 29 40 - 0
20/20 85 / 509 78 / 392 72 / 308 67 / 247 62 / 201 58 / 165 52 / 116 47 / 85 - - 37 - 4
Form Deck
20/18 85 / 569 78 / 438 72 / 344 67 / 276 62 / 224 58 / 185 52 / 130 47 / 95 - - 36 - 6
Double
18/20 140 / 665 128 / 512 118 / 403 110 / 322 103 / 262 96 / 216 86 / 152 77 / 111 - - 40 - 0
18/18 140 / 717 128 / 552 118 / 435 110 / 348 103 / 283 96 / 233 86 / 164 77 / 119 - - 40 - 0
20/20 96 / 398 88 / 307 81 / 241 76 / 193 71 / 157 - - - - - 37 - 10
20/18 96 / 445 88 / 343 81 / 270 76 / 216 71 / 175 - - - - - 36 - 11
Triple
18/20 159 / 520 146 / 401 135 / 315 125 / 252 117 / 205 - - - - - 40 - 0
18/18 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 47
Deep-Dek® 4.5 Cellular Acoustical
Table of Contents
16/18 40 7.446 7.446 7.446 6.646 2.430 2.574 58202 61646 6723 1518 2917
16/16 40 7.951 7.951 7.951 7.363 2.474 2.650 59260 63462 6723 1518 2917
14/16 40 9.354 9.354 9.354 8.624 3.327 3.252 79688 77903 9675 2279 4341
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite
13 -0 14 -0 15 -0 16 -0 17 -0 18 -0 20 -0 22 - 0 24 -0 26 -0 (ctr / ctr)
18/16 152 / 192 141 / 154 123 / 125 108 / 103 95 / 86 85 / 72 69 / 53 57 / 40 48 / 31 41 / 24 40 - 0
16/18 230 / 222 198 / 178 172 / 145 152 / 119 134 / 99 120 / 84 97 / 61 80 / 46 67 / 35 57 / 28 40 - 0
Single
16/16 233 / 237 202 / 190 176 / 154 154 / 127 137 / 106 122 / 89 99 / 65 82 / 49 69 / 38 58 / 30 40 - 0
14/16 314 / 279 271 / 223 236 / 182 208 / 150 184 / 125 164 / 105 133 / 77 110 / 58 92 / 44 79 / 35 40 - 0
18/16 118 / 464 110 / 371 103 / 302 96 / 249 91 / 207 86 / 175 77 / 127 - - - 40 - 0
Form Deck
16/18 179 / 536 167 / 429 156 / 349 146 / 287 137 / 240 124 / 202 101 / 147 - - - 40 - 0
Double
16/16 179 / 572 167 / 458 156 / 372 146 / 307 137 / 256 128 / 216 104 / 157 - - - 40 - 0
14/16 267 / 673 248 / 539 225 / 438 199 / 361 176 / 301 158 / 254 128 / 185 - - - 40 - 0
18/16 135 / 363 125 / 291 117 / 236 - - - - - - - 40 - 0
16/18 204 / 419 189 / 336 177 / 273 - - - - - - - 40 - 0
Triple
16/16 204 / 448 189 / 358 177 / 291 - - - - - - - 40 - 0
Typical Fastener Layouts
14/16 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
48 www.newmill.com/digital-tools
Deep-Dek® 6.0 Cellular
Table of Contents
Roof Decks - Type 6.0DC Cellular
PROPERTIES
7 87 ˝ 12˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 4.83
20/18 0.0358/0.0474 5.40 6 81 ˝
24
18/20 0.0474/0.0358 5.82
Roof Deck
18/18 0.0474/0.0474 6.39
24˝ Coverage ICC-ES APPROVED
REFER TO ESR-2657
Composite Deck
20/18 40 8.430 9.008 7.759 8.626 1.418 2.286 33960 54745 1391 552 1156
18/20 40 10.713 10.713 10.524 9.414 2.346 2.862 56190 68560 3235 940 1913
18/18 40 11.495 11.495 11.248 10.507 2.335 2.958 55937 70852 3235 940 1913
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
14 -0 15 -0 16 - 0 17 - 0 18 - 0 19 -0 20 -0 22 -0 24 -0 26 -0 (ctr / ctr)
20/20 79 / 189 74 / 154 69 / 127 65 / 106 61 / 89 58 / 76 55 / 65 47 / 49 39 / 38 33 / 30 38 - 7
20/18 79 / 201 74 / 164 69 / 135 65 / 112 61 / 95 58 / 81 55 / 69 47 / 52 39 / 40 33 / 31 37 - 6
Single
18/20 134 / 256 125 / 208 118 / 171 111 / 143 104 / 120 99 / 102 94 / 88 77 / 66 65 / 51 55 / 40 40 - 0
18/18 134 / 275 125 / 223 118 / 184 111 / 153 104 / 129 99 / 110 93 / 94 77 / 71 65 / 55 55 / 43 40 - 0
20/20 66 / 467 62 / 380 58 / 313 54 / 261 51 / 220 49 / 187 46 / 160 - - - 40 - 0
Form Deck
20/18 66 / 519 62 / 422 58 / 348 54 / 290 51 / 244 49 / 208 46 / 178 - - - 40 - 0
Double
18/20 109 / 617 102 / 502 96 / 413 90 / 345 85 / 290 81 / 247 77 / 212 - - - 40 - 0
18/18 109 / 662 102 / 538 96 / 444 90 / 370 85 / 312 81 / 265 77 / 227 - - - 40 - 0
20/20 75 / 365 70 / 297 - - - - - - - - 40 - 0
20/18 75 / 406 70 / 330 - - - - - - - - 40 - 0
Triple
18/20 124 / 483 116 / 393 - - - - - - - - 40 - 0
18/18 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 49
Deep-Dek® 6.0 Cellular
Table of Contents
16/18 40 14.204 14.204 14.204 12.437 3.514 3.665 84165 87794 6510 1452 2900
16/16 40 15.167 15.167 15.167 13.682 3.500 3.772 83837 90337 6510 1452 2900
14/16 40 17.832 17.832 17.832 16.050 4.779 4.627 114468 110823 10491 2192 4319
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite
15 -0 16 -0 17 -0 18 -0 20 -0 22 - 0 24 - 0 26 -0 28 -0 30 -0 (ctr / ctr)
18/16 125 / 236 118 / 194 111 / 162 104 / 137 93 / 100 77 / 75 65 / 58 55 / 45 47 / 36 41 / 29 40 - 0
16/18 194 / 276 181 / 227 171 / 190 161 / 160 140 / 116 116 / 87 97 / 67 83 / 53 72 / 42 62 / 34 40 - 0
Single
16/16 194 / 295 181 / 243 171 / 202 161 / 170 140 / 124 115 / 93 97 / 72 83 / 57 71 / 45 62 / 37 40 - 0
14/16 292 / 346 274 / 285 258 / 238 236 / 200 191 / 146 158 / 110 132 / 85 113 / 67 97 / 53 85 / 43 40 - 0
18/16 102 / 569 96 / 469 90 / 391 85 / 329 77 / 240 - - - - - 40 - 0
Form Deck
16/18 155 / 665 145 / 548 136 / 457 129 / 385 116 / 281 - - - - - 40 - 0
Double
16/16 155 / 710 145 / 585 136 / 488 129 / 411 116 / 300 - - - - - 40 - 0
14/16 230 / 835 216 / 688 203 / 574 192 / 483 173 / 352 - - - - - 40 - 0
18/16 116 / 445 - - - - - - - - - 40 - 0
16/18 176 / 521 - - - - - - - - - 40 - 0
Triple
16/16 176 / 556 - - - - - - - - - 40 - 0
Typical Fastener Layouts
14/16 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
50 www.newmill.com/digital-tools
Deep-Dek® 6.0 Cellular Acoustical
Table of Contents
Roof Decks - Type 6.0DCA Cellular
PROPERTIES
7 87 ˝ 12˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 4.67
20/18 0.0358/0.0474 5.19 6 81 ˝
24
18/20 0.0474/0.0358 5.66
Roof Deck
18/18 0.0474/0.0474 6.18
24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657
Composite Deck
20/18 40 8.242 8.910 7.612 8.615 1.417 2.285 33946 54726 1391 552 1156
18/20 40 10.434 10.434 10.252 9.417 2.350 2.863 56281 68568 3235 940 1913
18/18 40 11.228 11.228 11.012 10.497 2.338 2.957 55994 70835 3235 940 1913
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Deep-Dek®
14 -0 15 -0 16 - 0 17 - 0 18 - 0 19 -0 20 -0 22 -0 24 -0 26 -0 (ctr / ctr)
20/20 79 / 185 74 / 150 69 / 124 65 / 103 61 / 87 58 / 74 55 / 63 47 / 48 39 / 37 33 / 29 38 - 10
20/18 79 / 197 74 / 160 69 / 132 65 / 110 61 / 93 58 / 79 55 / 68 47 / 51 39 / 39 33 / 31 37 - 11
Single
18/20 134 / 249 125 / 203 118 / 167 111 / 139 104 / 117 99 / 100 94 / 86 78 / 64 65 / 49 56 / 39 40 - 0
18/18 134 / 268 125 / 218 118 / 180 111 / 150 104 / 126 99 / 107 93 / 92 77 / 69 65 / 53 55 / 42 40 - 0
20/20 66 / 462 62 / 376 58 / 310 54 / 258 51 / 218 49 / 185 46 / 159 - - - 40 - 0
Form Deck
20/18 66 / 513 62 / 417 58 / 344 54 / 287 51 / 242 49 / 205 46 / 176 - - - 40 - 0
Double
18/20 109 / 601 102 / 489 96 / 403 90 / 336 85 / 283 81 / 240 77 / 206 - - - 40 - 0
18/18 109 / 647 102 / 526 96 / 433 90 / 361 85 / 304 81 / 259 77 / 222 - - - 40 - 0
20/20 75 / 362 70 / 294 - - - - - - - - 40 - 0
20/18 75 / 402 70 / 327 - - - - - - - - 40 - 0
Triple
18/20 124 / 470 116 / 382 - - - - - - - - 40 - 0
18/18 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 51
Deep-Dek® 6.0 Cellular Acoustical
Table of Contents
16/18 40 13.824 13.824 13.824 12.429 3.486 3.665 83492 87779 6510 1452 2900
16/16 40 14.749 14.749 14.749 13.649 3.508 3.769 84032 90281 6510 1452 2900
14/16 40 17.351 17.351 17.351 16.019 4.741 4.624 113551 110765 10491 2193 4319
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite
15 -0 16 -0 17 -0 18 -0 20 -0 22 - 0 24 - 0 26 -0 28 -0 30 -0 (ctr / ctr)
18/16 125 / 230 118 / 190 111 / 158 104 / 133 93 / 97 77 / 73 65 / 56 55 / 44 48 / 35 41 / 29 40 - 0
16/18 194 / 269 181 / 221 171 / 184 161 / 155 139 / 113 115 / 85 97 / 66 82 / 52 71 / 41 62 / 34 40 - 0
Single
16/16 194 / 286 181 / 236 171 / 197 161 / 166 140 / 121 116 / 91 97 / 70 83 / 55 71 / 44 62 / 36 40 - 0
14/16 292 / 337 274 / 278 258 / 232 234 / 195 189 / 142 156 / 107 131 / 82 112 / 65 97 / 52 84 / 42 40 - 0
18/16 102 / 556 96 / 458 90 / 382 85 / 322 77 / 235 - - - - - 40 - 0
Form Deck
16/18 155 / 647 145 / 533 136 / 445 129 / 375 116 / 273 - - - - - 40 - 0
Double
16/16 155 / 691 145 / 569 136 / 475 129 / 400 116 / 291 - - - - - 40 - 0
14/16 230 / 813 216 / 670 203 / 558 192 / 470 173 / 343 - - - - - 40 - 0
18/16 116 / 435 - - - - - - - - - 40 - 0
16/18 176 / 507 - - - - - - - - - 40 - 0
Triple
16/16 176 / 541 - - - - - - - - - 40 - 0
Typical Fastener Layouts
14/16 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
52 www.newmill.com/digital-tools
Deep-Dek® 7.5 Cellular
Table of Contents
Roof Decks - Type 7.5DC Cellular
PROPERTIES
7 87 ˝ 12˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 5.17
20/18 0.0358/0.0474 5.74 7 85 ˝
24
18/20 0.0474/0.0358 6.27
Roof Deck
18/18 0.0474/0.0474 6.85
ICC-ES APPROVED
24˝ Coverage REFER TO ESR-2657
Composite Deck
(ksi)
20/20 40 12.639 13.197 11.608 12.445 1.787 2.922 42796 69981 1108 521 1148
20/18 40 13.461 14.636 12.234 13.997 1.787 3.030 42795 72584 1108 521 1148
18/20 40 17.211 17.211 16.796 15.352 2.958 3.785 70852 90657 2575 896 1902
18/18 40 18.349 18.349 17.772 17.060 2.948 3.916 70602 93787 2575 896 1902
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Deep-Dek®
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
17 -0 18 - 0 19 -0 20 -0 22 -0 24 -0 26 -0 28 -0 30 -0 32 -0 (ctr / ctr)
20/20 61 / 169 58 / 142 55 / 121 52 / 104 47 / 78 43 / 60 40 / 47 36 / 38 32 / 31 28 / 25 40 - 0
20/18 61 / 180 58 / 151 55 / 129 52 / 110 47 / 83 43 / 64 40 / 50 36 / 40 32 / 33 28 / 27 40 - 0
Single
18/20 105 / 230 100 / 193 94 / 164 90 / 141 81 / 106 75 / 82 69 / 64 60 / 51 52 / 42 46 / 34 40 - 0
Form Deck
18/18 105 / 245 100 / 206 94 / 175 90 / 150 81 / 113 75 / 87 69 / 68 60 / 55 52 / 45 46 / 37 40 - 0
20/20 54 / 425 51 / 358 48 / 304 46 / 261 - - - - - - 40 - 0
20/18 54 / 471 51 / 397 48 / 337 46 / 289 - - - - - - 40 - 0
Double
18/20 90 / 554 85 / 466 80 / 397 76 / 340 - - - - - - 40 - 0
18/18 90 / 590 85 / 497 80 / 423 76 / 363 - - - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
General Information
18/18 40 9 - 11 5 - 11 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 53
Deep-Dek® 7.5 Cellular
Table of Contents
24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 40 19.380 19.503 18.646 18.832 2.942 4.038 70476 96718 2575 896 1902
16/18 40 23.094 23.094 23.094 20.217 4.447 4.846 106525 116074 5178 1394 2886
16/16 40 24.659 24.659 24.659 22.170 4.422 4.992 105918 119561 5178 1394 2886
14/16 40 28.977 28.977 28.977 26.028 6.346 6.118 152001 146538 10113 2117 4300
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
20 -0 21 -0 22 - 0 23 - 0 24 - 0 26 - 0 28 - 0 30 -0 32 -0 34 -0 (ctr / ctr)
18/16 90 / 159 85 / 137 81 / 119 78 / 104 75 / 92 69 / 72 60 / 58 52 / 47 46 / 39 41 / 32 40 - 0
16/18 139 / 189 133 / 163 127 / 142 121 / 124 116 / 110 105 / 86 91 / 69 79 / 56 69 / 46 61 / 39 40 - 0
Single
16/16 139 / 202 133 / 175 127 / 152 121 / 133 116 / 117 104 / 92 90 / 74 78 / 60 69 / 49 61 / 41 40 - 0
Form Deck
14/16 212 / 237 202 / 205 192 / 178 184 / 156 176 / 137 150 / 108 129 / 87 113 / 70 99 / 58 88 / 48 40 - 0
18/16 76 / 385 72 / 333 - - - - - - - - 40 - 0
16/18 115 / 456 110 / 394 - - - - - - - - 40 - 0
Double
16/16 115 / 487 110 / 421 - - - - - - - - 40 - 0
14/16 172 / 573 164 / 495 - - - - - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
Typical Fastener Layouts
14/16 40 9 - 11 5 - 11 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
54 www.newmill.com/digital-tools
Deep-Dek® 7.5 Cellular Acoustical
Table of Contents
Roof Decks - Type 7.5DCA Cellular
PROPERTIES
Gage Thickness Cover Weight 7 87 ˝ 12˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 5.01
20/18 0.0358/0.0474 5.54
24 7 85 ˝
18/20 0.0474/0.0358 6.12
Roof Deck
18/18 0.0474/0.0474 6.64
24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657
Composite Deck
(ksi)
20/20 40 12.361 13.064 11.391 12.445 1.787 2.922 42791 69984 1108 521 1148
20/18 40 13.164 14.476 12.008 13.976 1.786 3.029 42780 72554 1108 521 1148
18/20 40 16.840 16.840 16.474 15.354 2.961 3.785 70923 90663 2575 896 1902
18/18 40 17.934 17.934 17.416 17.041 2.950 3.914 70649 93759 2575 896 1902
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Deep-Dek®
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
17 -0 18 - 0 19 -0 20 -0 22 -0 24 -0 26 -0 28 -0 30 -0 32 -0 (ctr / ctr)
20/20 61 / 165 58 / 139 55 / 118 52 / 101 47 / 76 43 / 59 40 / 46 36 / 37 32 / 30 28 / 25 40 - 0
20/18 61 / 176 58 / 148 55 / 126 52 / 108 47 / 81 43 / 62 40 / 49 36 / 39 32 / 32 28 / 26 40 - 0
Single
18/20 105 / 225 100 / 189 94 / 161 90 / 138 81 / 104 75 / 80 69 / 63 60 / 50 53 / 41 46 / 34 40 - 0
Form Deck
18/18 105 / 239 100 / 202 94 / 171 90 / 147 81 / 110 75 / 85 69 / 67 60 / 54 52 / 44 46 / 36 40 - 0
20/20 54 / 420 51 / 354 48 / 301 46 / 258 - - - - - - 40 - 0
20/18 54 / 466 51 / 392 48 / 334 46 / 286 - - - - - - 40 - 0
Double
18/20 90 / 542 85 / 456 80 / 388 76 / 333 - - - - - - 40 - 0
18/18 90 / 577 85 / 486 80 / 413 76 / 354 - - - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
General Information
18/18 40 9 - 11 5 - 11 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 55
Deep-Dek® 7.5 Cellular Acoustical
Table of Contents
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 40 18.937 19.273 18.270 18.775 2.943 4.035 70502 96637 2575 896 1902
16/18 40 22.483 22.483 22.483 20.200 4.458 4.845 106773 116047 5178 1394 2886
16/16 40 23.982 23.982 23.982 22.115 4.430 4.988 106112 119477 5178 1394 2886
14/16 40 28.205 28.205 28.205 25.976 6.292 6.114 150718 146450 10113 2117 4300
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
20 -0 21 -0 22 - 0 23 - 0 24 - 0 26 - 0 28 - 0 30 -0 32 -0 34 -0 (ctr / ctr)
18/16 90 / 155 85 / 134 81 / 117 78 / 102 75 / 90 69 / 71 60 / 57 52 / 46 46 / 38 41 / 32 40 - 0
16/18 139 / 184 133 / 159 127 / 138 121 / 121 116 / 107 105 / 84 91 / 67 79 / 55 70 / 45 62 / 37 40 - 0
Single
16/16 139 / 197 133 / 170 127 / 148 121 / 129 116 / 114 105 / 89 90 / 72 79 / 58 69 / 48 61 / 40 40 - 0
Form Deck
14/16 212 / 231 202 / 200 192 / 174 184 / 152 174 / 134 149 / 105 128 / 84 112 / 68 98 / 56 87 / 47 40 - 0
18/16 76 / 381 72 / 329 - - - - - - - - 40 - 0
16/18 115 / 444 110 / 384 - - - - - - - - 40 - 0
Double
16/16 115 / 474 110 / 409 - - - - - - - - 40 - 0
14/16 172 / 557 164 / 481 - - - - - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
Typical Fastener Layouts
14/16 40 9 - 11 5 - 11 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.
Discover the easiest way to specify Steel Roof and Floor Deck:
56 www.newmill.com/digital-tools
Long-Span Composite
Table of Contents Roof Deck Composite Deck Form Deck Typical Fastener Layouts General Information Code of Standard Practice
Versa-Dek® Deep-Dek®
Long-Span Composite
Code of Standard Practice General Information Typical Fastener Layouts Form Deck Composite Deck Roof Deck Table of Contents
Versa-Dek® Deep-Dek®
Composite Deck
Table of Contents
Composite deck has embossments in the vertical ribs that bond with the
concrete slab to develop a composite floor system. Composite deck acts as a form
during the concrete pour. The resulting composite floor system provides superior
strength and stiffness. Click on the links below to view load tables.
Roof Deck
Standard Composite
Composite Deck
1.5 Composite Deck......................................................................................... 60 – 63
1.5-inch composite deck, standard
and interlocking options available
Versa-Dek®
Long-Span Composite
2-inch composite deck
Deep-Dek®
3-inch composite deck
Cellular Composite
Form Deck
1.5 Cellular Composite Deck........................................................................ 68 – 75
1.5-inch cellular composite deck, available
with or without acoustical properties
newmill.com 59
1.5CD, 1.5CDI Composite Deck
Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks
6˝
- Types 1.5CD, 1.5CDI
185 ˝ 2 21 ˝
PROPERTIES
Thickness Cover Weight
Gage (in) (in) (psf)
22 0.0295 1.63 1 21 ˝
20 0.0358 1.98 ICC-ES APPROVED
18 0.0474
36
2.62 36˝ Coverage ICC-ES Approved -
REFER TO ESR-3818
Refer to ESR-3818
Roof Deck
16 0.0598 3.30
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.480 0.163 0.175 0.157 0.175 0.176 0.183 4215 4391 2009 654 1181
20 40 0.582 0.205 0.213 0.201 0.213 0.224 0.235 5375 5624 2428 932 1696
18 40 0.770 0.280 0.281 0.279 0.281 0.304 0.315 7291 7553 3192 1557 2858
16 40 0.971 0.355 0.355 0.355 0.355 0.390 0.395 9332 9454 3996 2381 4396
CONSTRUCTION CLEAR SPANS
Composite Deck
16 9 - 11 10 - 10 11 - 3 3 - 9
Long-Span Composite
16 8 - 6 9 - 6 9 - 10 3 - 3
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric (in2/ft)
Lightweight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
60 www.newmill.com/digital-tools
1.5CD, 1.5CDI Composite Deck
Table of Contents
Composite Decks
Composite Decks -- Types
Types 1.5CD,
1.5CD, 1.5CDI
1.5CDI
NORMAL-WEIGHT CONCRETE
PROPERTIES 6˝ 185 ˝
PROPERTIES 2 21 ˝
Thickness Coverage Weight
Gage Thickness Cover Weight
(in) (in) (psf)
Gage (in) (in) (psf)
22 0.0295 1.63
22
20 0.0295
0.0358 1.63
1.98
1 21 ˝
20
18 0.0358
0.0474
36
36
1.98
2.62 ICC-ES
ICC-ES Approved
ICC-ES Approved --
APPROVED
18 0.0474 2.62 36˝ Coverage Refer
16
16
0.0598
0.0598
3.30
3.30 Refer to
REFER to ESR-3818
TO ESR-3818
ESR-3818
Roof Deck
ASD
ASD SECTION PROPERTIES
SECTION PROPERTIES DESIGN STRENGTHS
DESIGN STRENGTHS (No
(No Concrete Fill)
Concrete Fill)
F A I 1 Span I 2+ Span I I S S Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage Fyy Ass IDD 1 Span IDD 2+ Span Ipp Inn Spp Snn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage (ksi) (in22/ft) (in44/ft) 4
(in4 /ft)
4
(in4 /ft)
4
(in4 /ft)
3
(in3 /ft)
3
(in3 /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.480 0.163 0.175 0.157 0.175 0.176 0.183 4215 4391 2009 654 1181
22 40 0.480 0.163 0.175 0.157 0.175 0.176 0.183 4215 4391 2009 654 1181
20 40 0.582 0.205 0.213 0.201 0.213 0.224 0.235 5375 5624 2428 932 1696
20 40 0.582 0.205 0.213 0.201 0.213 0.224 0.235 5375 5624 2428 932 1696
18 40 0.770 0.280 0.281 0.279 0.281 0.304 0.315 7291 7553 3192 1557 2858
18 40 0.770 0.280 0.281 0.279 0.281 0.304 0.315 7291 7553 3192 1557 2858
16 40 0.971 0.355 0.355 0.355 0.355 0.390 0.395 9332 9454 3996 2381 4396
16 40 0.971 0.355 0.355 0.355 0.355 0.390 0.395 9332 9454 3996 2381 4396
CONSTRUCTION CLEAR
CONSTRUCTION CLEAR SPANS
SPANS
Concrete Maximum Construction
Construction Concrete Notes:
Composite Deck
Total Slab
Slab Concrete Maximum Concrete Notes:
Total Gage Weight Clear Span
Span (ft
(ft -- in)
in) Volume 1. Section properties are calculated in accordance with the
Depth (in) Gage Weight Clear Volume 1. Section properties are calculated in accordance with the
Depth (in) (psf) Single Double Triple Cantilever (ft 3
/ft22))
(ft3/ft
AISI S100-16.
AISI S100-16.
(psf) Single Double Triple Cantilever 2. Web crippling design strengths* and maximum construction
22
22 56 -- 92 67 -- 93 67 -- 4
10 22 -- 00 2. Web
spans crippling
are based design
on 1strengths*
1/2'' for endand maximum
bearing and construction
3'' for interior
20
20 67 -- 94 88 -- 05 88 -- 19 22 -- 56 spans are Check
based on 1 1/2'' for end bearing and
are3''
notfor interior
33 1/2
1/2
18
23
31 0.213
0.213 bearing. web crippling if minimums met.
18 89 -- 40 99 -- 89 10
9 -- 1
11 33 -- 13 3. bearing.
MaximumCheck web crippling
construction spansifareminimums
based onare not met.C-2017
ANSI/SDI
16
16 10
9 -- 86 10
10 -- 910 11
11 -- 13 33 -- 89 Standard for Compositespans
SteelareFloor Deck
3. Maximum construction based onand the following
ANSI/SDI C-2017
22
22 55 -- 510 66 -- 511 67 -- 60 12 -- 0
11 construction loading: Steel Floor Deck and the following
20 Standard for Composite
44
20 28 67 -- 50 78 -- 73 78 -- 84 22 -- 45 0.255 ● Deck self-weight and concrete weight plus worst-case of
pcf)
18
18 78 -- 7
11 99 -- 29 10
9 -- 41 33 -- 02 either a 150 lb. concentrated load or a 20 psf
16 99 -- 111 10 -- 210 11 -- 63 33 -- 69
● Deck self-weight and concrete weight plus worst-case of
Versa-Dek®
16 10 10 uniform load; or
Long-Span Composite
Concrete(110
22
22 55 -- 38 66 -- 28 66 -- 39 11 -- 11
10 ● either a 150 lb.concentrated
Deck self-weight plus a 50 psf load or a 20
uniform psf
construction
20
20 66 -- 28 77 -- 310 77 -- 411 22 -- 35 uniform load; or controls.
44 1/2
1/2 33 0.297 load, whichever
Light Weight Concrete
18 43 0.297
18 78 -- 62 89 -- 96 89 -- 9
10 23 -- 0
10 4. ● Deck self-weight
Concrete weights do plus
nota include
50 psf uniform construcon
weight of deck.
16
16 89 -- 86 10
9 -- 87 10
10 -- 111 33 -- 47 5. Deckload, whichever
profile controls.
has been accounted for in determining concrete
22
22 55 -- 05 56 -- 5
11 56 -- 6
11 11 -- 11
10 volumes. weights
Deck and
20 4. Concrete do support deflections
not include have
weight of not been
deck.
56 -- 5 67 -- 7 77 -- 08 22 -- 34
Normal-Weight
20 11 11
55 37 0.338
Deep-Dek®
included
5. Deck in concrete
profile has beenvolumes
accounted or weights.
for in determining concrete
18 49 0.338
18 77 -- 210 89 -- 42 89 -- 64 23 -- 90 6. Cantilever clear spans assume adjacent clear span is at least
volumes. Deck and support deflections have not been
16
16 89 -- 41 10
9 -- 32 10
9 -- 76 33 -- 26 3 times longer than the cantilever clear span and no greater
22
22 45 -- 3
10 56 -- 82 56 -- 93 11 -- 910 included in concrete volumes or weights.
than spans shown. Bearing width at perimeter support
20
20 56 -- 82 67 -- 83 67 -- 94 22 -- 23 6. Cantilever clear spans assumeContact
adjacentNMBS
clear span is at least
55 1/2
1/2
18
42
55 0.380
0.380 assumed to be 3'' minimum. otherwise.
18 67 -- 7
11 88 -- 010 88 -- 211 22 -- 811 3 times longer than the cantilever clear span and no greater
16
16 88 -- 09 89 -- 10
11 10
9 -- 32 33 -- 14 than spans shown. Bearing width at perimeter support
22
22 45 -- 81 56 -- 60 56 -- 71 11 -- 910 assumed to be 3''minimum. Contact New Millennium
20
20 56 -- 60 67 -- 50 67 -- 61 22 -- 13
66 18
46
61 0.422
0.422 otherwise.
18 67 -- 84 78 -- 96 78 -- 8
10 22 -- 710
Form Deck
16
16 78 -- 96 89 -- 76 89 -- 10
11 23 -- 3
11
SLAB DESIGN
SLAB DESIGN -- ALLOWABLE
ALLOWABLE SUPERIMPOSED
SUPERIMPOSED UNIFORM
UNIFORM LOADS
LOADS AND
AND MINIMUM
MINIMUM SDI
SDI SLAB
SLAB REINFORCEMENT
REINFORCEMENT
Total Slab
Total Slab Allowable Superimposed
Allowable Superimposed Uniform
Uniform LoadLoad (psf)
(psf) Recommended Wire
Recommended
Depth
Depth Gage
Gage Clear Span
Clear Span (ft
(ft -- in)
in) Welded Wire
Welded Wire Area
(in) Fabric (in2/ft)
9)
66 -- 00 66 -- 66 77 -- 00 77 -- 66 88 -- 00 88 -- 66 99 -- 00 10 -- 00 11 -- 00 2
Fabric
psi,n n= =14)
22
22 359
370 302
310 256
262 219
223 189
191 164
165 143
143 110
109 86
83
20
20 400
400 361
375 308
318 264
272 228
234 199
203 174
177 135
136 107
105 6x6 --
6x6
44 18 400 400 397 342 297 259 225 164 123 W1.4xW1.4
0.028
0.028
18 400 400 400 357 309 269 236 183 145 W1.4xW1.4
16
16 400
400 400
400 400
400 400
400 355
385 296
336 249
295 182
229 137
172
145pcf,
22
22 400
400 368
377 313
319 268
272 232
234 201
202 176
175 136
133 106
103
20 400 400 376 323 280 244 214 167 132 6x6 --
(γc= =110
20 400 400 387 331 286 248 216 167 130 6x6
44 1/2
1/2
18 400 400 400 400 365 319 281 221 174 W1.4xW1.4
0.028
0.028
18 400 400 400 400 378 330 289 225 178 W1.4xW1.4
16
16 400
400 400
400 400
400 400
400 400
400 395
400 348
363 257
285 193
228
Concrete(γc
22
22 400
400 400
400 372
378 319
322 276
277 240
240 210
208 162
159 127
123
Light Weight Concrete
20
20 400
400 400
400 400
400 385
393 334
339 291
295 255
258 199
199 158
156 6x6 --
6x6
55 18 400 400 400 400 400 382 336 265 212 W2.0xW2.0
0.040
0.040
18 400 400 400 400 400 392 344 269 213 W2.0xW2.0
16 400 400 400 400 400 400 400 331 263
General Information
16 400 400 400 400 400 400 400 341 273
Normal-Weight
22
22 400
400 400
400 400
400 371
374 321
322 279
279 244
242 190
186 149
144
20
20 400
400 400
400 400
400 400
400 389
394 339
343 298
300 233
232 185
182 6x6 --
6x6
55 1/2
1/2
18 400 400 400 400 400 400 393 310 248 W2.0xW2.0
0.040
0.040
18 400 400 400 400 400 400 400 314 249 W2.0xW2.0
16
16 400
400 400
400 400
400 400
400 400
400 400
400 400
400 388
398 313
319
22
22 400
400 400
400 400
400 400
400 367
367 319
318 280
277 217
212 171
165
20
20 400
400 400
400 400
400 400
400 400
400 389
392 341
342 267
265 213
208 4x4 --
4x4
66 18 400 400 400 400 400 400 400 356 286 W1.4xW1.4
0.042
0.042
18 400 400 400 400 400 400 400 360 286 W1.4xW1.4
16
16 400
400 400
400 400
400 400
400 400
400 400
400 400
400 400
400 360
366
Notes: 7.
Notes: 7. Welded
Welded wire
wire fabric
fabric shown
shown in
in the
the table
table below
above is the SDI
is the minimum required
SDI minimum required for
for temperature
temperatureand
andshrinkage
shrinkage (0.00075
(0.00075 xx concrete
concrete area above top
area above top of
of deck).
deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
Code of Standard Practice
●●Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
Single span conditions without negative bending reinforcing over supports.
●●Single span condions
The presence of shearwithout negave
studs have bending
not been reinforcing
considered, over strength
design supports.may be increased if shear studs are used.
●●The
Slabpresence of is
deflection shear studs
limited have not been
to minimum considered,
of Clear Span/360design strength
or 1'' under may be
service increased
level if shearloading.
superimposed studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 61
1.5CDR Composite Deck
Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks4-˝ Type 1.5CDR 3
8
PROPERTIES
Thickness Cover Weight 1 21 ˝
Gage (in) (in) (psf)
6˝
22 0.0295 1.63 3 21 ˝
20 0.0358 1.98 ICC-ES APPROVED
36
18 0.0474 2.62 36˝ Coverage REFER TO ESR-3818
Roof Deck
16 0.0598 3.30
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.480 0.175 0.175 0.175 0.157 0.183 0.176 4391 4215 2009 654 1181
20 40 0.582 0.213 0.213 0.213 0.201 0.235 0.224 5624 5375 2428 932 1696
18 40 0.770 0.281 0.281 0.281 0.279 0.315 0.304 7553 7291 3192 1557 2858
16 40 0.971 0.355 0.355 0.355 0.355 0.395 0.390 9454 9332 3996 2381 4396
CONSTRUCTION CLEAR SPANS
Composite Deck
16 9 - 6 10 - 7 10 - 11 3 - 7
Long-Span Composite
16 8 - 3 9 - 2 9 - 6 3 - 2
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric (in2/ft)
Lightweight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)
18 400 400 400 335 276 230 194 141 106 W1.4xW1.4
16 400 400 400 371 305 255 215 156 118
22 400 382 325 279 241 209 183 142 112
20 400 400 392 337 292 255 224 175 137 6x6 -
4 0.028
18 400 400 400 400 383 333 281 204 154 W1.4xW1.4
16 400 400 400 400 400 368 310 226 170
22 400 400 385 330 285 248 218 169 133
20 400 400 400 400 347 303 266 208 165 6x6 -
4 1/2 0.028
18 400 400 400 400 400 398 351 277 213 W1.4xW1.4
16 400 400 400 400 400 400 400 313 235
22 400 400 400 383 331 288 253 197 155
20 400 400 400 400 400 351 309 242 192 6x6 -
5 0.040
18 400 400 400 400 400 400 400 323 259 W2.0xW2.0
16 400 400 400 400 400 400 400 400 314
General Information
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
62 www.newmill.com/digital-tools
1.5CDR Composite Deck
Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks4 -˝ Type 1.5CDR 3
8
PROPERTIES
Thickness Cover Weight 1 21 ˝
Gage (in) (in) (psf)
6˝
22 0.0295 1.63 3 21 ˝
20 0.0358 1.98 ICC-ES APPROVED
36
18 0.0474 2.62 36˝ Coverage REFER TO ESR-3818
16 0.0598 3.30
Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.480 0.175 0.175 0.175 0.157 0.183 0.176 4391 4215 2009 654 1181
20 40 0.582 0.213 0.213 0.213 0.201 0.235 0.224 5624 5375 2428 932 1696
18 40 0.770 0.281 0.281 0.281 0.279 0.315 0.304 7553 7291 3192 1557 2858
16 40 0.971 0.355 0.355 0.355 0.355 0.395 0.390 9454 9332 3996 2381 4396
CONSTRUCTION CLEAR SPANS
Concrete
Composite Deck
Concrete Maximum Construction Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
Depth (in) AISI S100-16.
(psf) Single Double Triple Cantilever (ft3/ft2)
22 5 - 8 6 - 8 6 - 9 1 - 10 2. Web crippling design strengths* and maximum construction
20 6 - 8 7 - 10 7 - 11 2 - 3 spans are based on 1 1/2'' for end bearing and 3'' for interior
3 1/2 36 0.250
18 8 - 1 9 - 1 9 - 4 2 - 11 bearing. Check web crippling if minimums are not met.
16 9 - 2 10 - 2 10 - 7 3 - 6 3. Maximum construction spans are based on ANSI/SDI C-2017
22 5 - 5 6 - 4 6 - 5 1 - 10 Standard for Composite Steel Floor Deck and the following
20 6 - 5 7 - 5 7 - 7 2 - 2
Normal-Weight Concrete (145 pcf)
Versa-Dek®
8 - 9 9 - 8 10 - 1 3 - 4
Long-Span Composite
22 5 - 2 6 - 1 6 - 2 1 - 9 either a 150 lb.concentrated load or a 20 psf
20 6 - 1 7 - 1 7 - 3 2 - 2 uniform load; or
4 1/2 48 0.333
18 7 - 5 8 - 3 8 - 6 2 - 9 ● Deck self-weight plus a 50 psf uniform construcon
16 8 - 5 9 - 3 9 - 7 3 - 2 load, whichever controls.
22 5 - 0 5 - 10 5 - 11 1 - 9 4. Concrete weights do not include weight of deck.
20 5 - 11 6 - 10 6 - 11 2 - 1
Deep-Dek®
5 54 0.375 5. Deck profile has been accounted for in determining concrete
18 7 - 1 7 - 11 8 - 2 2 - 8 volumes. Deck and support deflections have not been
16 8 - 1 8 - 11 9 - 3 3 - 1
22 included in concrete volumes or weights.
4 - 10 5 - 8 5 - 9 1 - 8
20 5 - 8 6 - 7 6 - 8 2 - 1 6. Cantilever clear spans assume adjacent clear span is at least
5 1/2 60 0.416 3 times longer than the cantilever clear span and no greater
18 6 - 10 7 - 7 7 - 11 2 - 7
16 7 - 10 8 - 7 8 - 11 2 - 11 than spans shown. Bearing width at perimeter support
22 4 - 8 5 - 6 5 - 6 1 - 8 assumed to be 3''minimum. Contact New Millennium
20 5 - 6 6 - 4 6 - 6 2 - 0 otherwise.
6 66 0.458
18 6 - 7 7 - 4 7 - 7 2 - 6
Form Deck
16 7 - 7 8 - 3 8 - 7 2 - 10
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
Normal-Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 63
2.0CD Composite Deck
Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 2.0CD
PROPERTIES Optional run-out side lap for screws
Thickness Cover Weight 2˝
Gage (in) (in) (psf) 5˝ 12˝ 2˝ ICC-ES APPROVED
22 0.0295 1.57 5˝
7˝ 12˝ REFER TO ESR-3818
20 0.0358 1.90
36 7˝ 36˝ Coverage
18 0.0474 2.52
Roof Deck
16 0.0598 3.17
36˝ Coverage
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.461 0.341 0.341 0.337 0.328 0.257 0.261 6153 6263 1474 321 617
20 40 0.559 0.419 0.419 0.418 0.410 0.342 0.346 8189 8285 1963 459 882
18 40 0.740 0.555 0.555 0.554 0.554 0.506 0.510 12108 12205 2590 769 1477
16 40 0.932 0.701 0.701 0.699 0.700 0.650 0.651 15572 15583 3255 1176 2260
CONSTRUCTION CLEAR SPANS
Composite Deck
16 11 - 10 13 - 8 13 - 10 4 - 7 controls.
22 7 - 2 8 - 4 8 - 6 2 - 7 4. Concrete weights do not include weight of deck.
20 8 - 7 9 - 8 10 - 0 3 - 3 5. Deck profile has been accounted for in determining concrete
5 36 0.331
18 10 - 9 11 - 8 12 - 1 4 - 0 volumes. Deck and support deflections have not been included in
16 11 - 5 13 - 2 13 - 5 4 - 5 concrete volumes or weights.
22 6 - 10 7 - 10 8 - 2 2 - 6 6. Cantilever clear spans assume adjacent clear span is at least 3 times
Versa-Dek®
20 8 - 3 9 - 3 9 - 7 3 - 1 longer than the cantilever clear span and no greater than spans
5 1/2 41 0.373
18 10 - 4 11 - 3 11 - 8 3 - 10 published above. Bearing width at perimeter support assumed to be 4''
16 11 - 1 12 - 8 13 - 1 4 - 4 minimum. Contact New Millennium otherwise.
22 6 - 8 7 - 4 7 - 10 2 - 5
20 8 - 0 9 - 0 9 - 3 3 - 0
6 46 0.414
18 10 - 0 10 - 10 11 - 3 3 - 9
16 10 - 9 12 - 3 12 - 8 4 - 2
22 6 - 5 6 - 10 7 - 7 2 - 5
20 7 - 9 8 - 8 8 - 11 2 - 11
6 1/2 50 0.456
Form Deck
18 9 - 8 10 - 6 10 - 10 3 - 7
16 10 - 5 11 - 10 12 - 3 4 - 1
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 7 - 0 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 Fabric (in2/ft)
Light Weight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)
4 0.028
18 372 277 242 213 167 127 97 77 61 W1.4xW1.4
16 400 309 271 238 187 140 108 85 68
22 287 212 184 161 124 97 76 60 47
20 347 257 224 196 153 120 96 77 61 6x6 -
4 1/2 0.028
18 400 337 295 259 203 162 131 106 85 W1.4xW1.4
16 400 376 329 290 228 183 148 118 94
22 340 252 219 191 147 115 91 72 57
20 400 306 266 233 182 144 115 92 74 6x6 -
5 0.028
18 400 400 351 308 242 194 156 128 105 W1.4xW1.4
16 400 400 392 346 272 218 177 145 120
22 396 293 255 222 172 135 107 84 67
20 400 356 310 272 212 168 134 108 87 6x6 -
5 1/2 0.040
18 400 400 400 360 283 227 183 150 123 W2.0xW2.0
General Information
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
64 www.newmill.com/digital-tools
2.0CD Composite Deck
Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 2.0CD
PROPERTIES Optional run-out side lap for screws
Thickness Cover Weight 2˝
Gage (in) (in) (psf) 5˝ 2˝
12˝ ICC-ES APPROVED
22 0.0295 1.57
5˝
7˝ 12˝ REFER TO ESR-3818
20 0.0358 1.90
36 7˝ 36˝ Coverage
18 0.0474 2.52
Roof Deck
16 0.0598 3.17
36˝ Coverage
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.461 0.341 0.341 0.337 0.328 0.257 0.261 6153 6263 1474 321 617
20 40 0.559 0.419 0.419 0.418 0.410 0.342 0.346 8189 8285 1963 459 882
18 40 0.740 0.555 0.555 0.554 0.554 0.506 0.510 12108 12205 2590 769 1477
16 40 0.932 0.701 0.701 0.699 0.700 0.650 0.651 15572 15583 3255 1176 2260
CONSTRUCTION CLEAR SPANS
Composite Deck
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the AISI S100-16.
Depth (in) 3 2 2. Web crippling design strengths* and maximum construction spans are
(psf) Single Double Triple Cantilever (ft /ft )
based on 2'' for end bearing and 4'' for interior bearing. Check web
22 7 - 2 8 - 5 8 - 6 2 - 7
crippling if minimums are not met.
20 8 - 8 9 - 8 10 - 0 3 - 3
4 36 0.248 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
18 10 - 9 11 - 9 12 - 2 4 - 0
16 11 - 6 13 - 2 13 - 6 4 - 6 Composite Steel Floor Deck and the following construction loading:
22 6 - 10 7 - 9 8 - 1 2 - 6 ● Deck self-weight and concrete weight plus worst-case of either a 150 lb.
20 8 - 3 9 - 3 9 - 7 3 - 1 concentrated load or a 20 psf uniform load; or
Normal Weight Concrete (145 pcf)
4 1/2 42 0.289
18 10 - 3 11 - 2 11 - 7 3 - 10 ● Deck self-weight plus a 50 psf uniform construcon load, whichever
Versa-Dek®
Long-Span Composite
16 11 - 0 12 - 7 13 - 0 4 - 4 controls.
22 6 - 6 7 - 1 7 - 9 2 - 5 4. Concrete weights do not include weight of deck.
20 7 - 10 8 - 9 9 - 1 3 - 0 5. Deck profile has been accounted for in determining concrete
5 48 0.331
18 9 - 10 10 - 8 11 - 0 3 - 8 volumes. Deck and support deflections have not been included in
16 10 - 7 12 - 0 12 - 5 4 - 1 concrete volumes or weights.
22 6 - 1 6 - 6 7 - 4 2 - 4 6. Cantilever clear spans assume adjacent clear span is at least 3 times
Deep-Dek®
20 7 - 6 8 - 5 8 - 9 2 - 11 longer than the cantilever clear span and no greater than spans
5 1/2 54 0.373
18 9 - 6 10 - 3 10 - 7 3 - 6 published above. Bearing width at perimeter support assumed to be 4''
16 10 - 2 11 - 6 11 - 11 3 - 11 minimum. Contact New Millennium otherwise.
22 5 - 6 6 - 0 6 - 10 2 - 3
20 7 - 3 8 - 1 8 - 5 2 - 9
6 60 0.414
18 9 - 2 9 - 10 10 - 2 3 - 4
16 9 - 10 11 - 1 11 - 6 3 - 10
22 5 - 0 5 - 6 6 - 3 2 - 1
20 7 - 0 7 - 10 8 - 1 2 - 8
6 1/2 66 0.456
Form Deck
18 8 - 10 9 - 6 9 - 10 3 - 3
16 9 - 7 10 - 8 11 - 1 3 - 8
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in2/ft)
Normal Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)
(in) 7 - 0 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 Fabric
22 241 176 151 131 99 75 57 43 32
20 293 215 187 162 124 96 75 58 45 6x6 -
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 65
3.0CD Composite Deck
Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 3.0CD
Optional run-out side lap for screws
PROPERTIES
Thickness Cover Weight 3˝
Gage (in) (in) (psf) ˝ ICC-ES APPROVED
22 0.0295 1.71
20 0.0358 2.07 ˝ REFER TO ESR-3818
36
18 0.0474 2.74
36˝ Coverage
Roof Deck
16 0.0598 3.45
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.502 0.770 0.770 0.764 0.750 0.407 0.424 9749 10151 1416 336 677
20 40 0.609 0.946 0.946 0.945 0.934 0.537 0.556 12871 13319 2227 482 967
18 40 0.805 1.253 1.253 1.252 1.253 0.794 0.802 19016 19213 3895 811 1615
16 40 1.015 1.580 1.580 1.579 1.579 1.012 1.013 24245 24264 4901 1245 2466
CONSTRUCTION CLEAR SPANS
Composite Deck
16 14 - 0 16 - 4 16 - 5 5 - 5 controls.
22 8 - 7 8 - 7 9 - 9 3 - 3 4. Concrete weights do not include weight of deck.
20 11 - 0 11 - 9 12 - 2 4 - 0 5. Deck profile has been accounted for in determining concrete
6 41 0.375
18 12 - 11 14 - 1 14 - 7 4 - 10 volumes. Deck and support deflections have not been included in
16 13 - 7 15 - 9 16 - 0 5 - 4 concrete volumes or weights.
22 7 - 9 8 - 0 9 - 1 3 - 0
Versa-Dek®
7 1/2 55 0.500
18 12 - 1 12 - 9 13 - 2 4 - 4
16 12 - 9 14 - 4 14 - 10 4 - 11
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0 16 - 0 Fabric (in2/ft)
Light Weight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
66 www.newmill.com/digital-tools
3.0CD Composite Deck
Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 3.0CD
Optional run-out side lap for screws
PROPERTIES
Thickness Cover Weight 3˝
Gage (in) (in) (psf) ˝ ICC-ES APPROVED
22 0.0295 1.71
20 0.0358 2.07 ˝ REFER TO ESR-3818
36
18 0.0474 2.74
36˝ Coverage
Roof Deck
16 0.0598 3.45
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.502 0.770 0.770 0.764 0.750 0.407 0.424 9749 10151 1416 336 677
20 40 0.609 0.946 0.946 0.945 0.934 0.537 0.556 12871 13319 2227 482 967
18 40 0.805 1.253 1.253 1.252 1.253 0.794 0.802 19016 19213 3895 811 1615
16 40 1.015 1.580 1.580 1.579 1.579 1.012 1.013 24245 24264 4901 1245 2466
CONSTRUCTION CLEAR SPANS
Composite Deck
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the AISI S100-16.
Depth (in) 2. Web crippling design strengths* and maximum construction spans are
(psf) Single Double Triple Cantilever (ft3/ft2)
based on 2 1/2'' for end bearing and 5'' for interior bearing. Check web
22 8 - 5 8 - 5 9 - 7 3 - 2
crippling if minimums are not met.
20 10 - 11 11 - 7 12 - 0 4 - 0
5 42 0.292 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
18 12 - 10 14 - 0 14 - 6 4 - 10
16 13 - 6 15 - 8 15 - 10 5 - 3 Composite Steel Floor Deck and the following construction loading:
22 7 - 5 7 - 8 8 - 9 2 - 11 ● Deck self-weight and concrete weight plus worst-case of either a 150 lb.
20 10 - 4 10 - 11 11 - 6 3 - 10 concentrated load or a 20 psf uniform load; or
Normal Weight Concrete (145 pcf)
5 1/2 48 0.333
18 12 - 5 13 - 4 13 - 10 4 - 7 ● Deck self-weight plus a 50 psf uniform construcon load, whichever
Versa-Dek®
Long-Span Composite
16 13 - 1 15 - 0 15 - 5 5 - 1 controls.
22 6 - 7 7 - 1 8 - 1 2 - 8 4. Concrete weights do not include weight of deck.
20 9 - 11 10 - 1 11 - 0 3 - 8 5. Deck profile has been accounted for in determining concrete
6 54 0.375
18 12 - 1 12 - 10 13 - 3 4 - 5 volumes. Deck and support deflections have not been included in
16 12 - 9 14 - 4 14 - 10 4 - 11 concrete volumes or weights.
22 5 - 11 6 - 7 7 - 5 2 - 5 6. Cantilever clear spans assume adjacent clear span is at least 3 times
Deep-Dek®
20 9 - 6 9 - 4 10 - 7 3 - 6 longer than the cantilever clear span and no greater than spans
6 1/2 60 0.417
18 11 - 9 12 - 4 12 - 9 4 - 3 published above. Bearing width at perimeter support assumed to be 5''
16 12 - 5 13 - 10 14 - 4 4 - 9 minimum. Contact New Millennium otherwise.
22 5 - 5 6 - 1 6 - 9 2 - 3
20 9 - 2 8 - 8 9 - 11 3 - 3
7 66 0.458
18 11 - 6 11 - 11 12 - 4 4 - 1
16 12 - 2 13 - 4 13 - 10 4 - 7
22 5 - 0 5 - 8 6 - 3 2 - 1
20 8 - 10 8 - 2 9 - 3 3 - 1
Form Deck
7 1/2 72 0.500
18 11 - 1 11 - 6 11 - 11 3 - 11
16 11 - 11 12 - 11 13 - 5 4 - 5
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in2/ft)
Normal Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)
(in) 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0 16 - 0 Fabric
22 229 171 130 100 77 59 45 34 24
6x6 -
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 67
1.5CFDC Composite Floor Deck Cellular
Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 1.5CFDC Cellular
PROPERTIES 6˝ 2 21 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 1 21 ˝
20/20 0.0358/0.0358 3.49 1 85 ˝
20/18 0.0358/0.0474
24.5
4.01 24 21 ˝ Coverage
18/20 0.0474/0.0358 4.09
Roof Deck
20/18 9 - 1 10 - 7 10 - 9 3 - 7 6. Cantilever clear spans assume adjacent clear span is at least 3 times
5 37 0.336
18/20 10 - 2 12 - 0 12 - 3 4 - 1 longer than the cantilever clear span and no greater than spans
18/18 10 - 6 13 - 2 12 - 6 4 - 4 published above. Bearing width at perimeter support assumed to be 3''
20/20 8 - 6 9 - 11 10 - 0 3 - 4 minimum. Contact New Millennium otherwise.
20/18 8 - 9 10 - 3 10 - 4 3 - 5
5 1/2 42 0.377
18/20 9 - 10 11 - 7 11 - 11 3 - 11
18/18 10 - 2 12 - 8 12 - 2 4 - 2
20/20 8 - 2 9 - 7 9 - 8 3 - 2
20/18 8 - 5 9 - 10 9 - 11 3 - 3
6 46 0.419
Form Deck
18/20 9 - 6 11 - 3 11 - 7 3 - 10
18/18 9 - 10 12 - 2 11 - 11 4 - 0
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric (in2/ft)
Lightweight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)
3 1/2 0.028
18/20 229 191 161 137 117 100 87 65 49 W1.4xW1.4
18/18 229 191 161 136 116 100 86 64 48
20/20 312 261 221 189 162 140 121 92 71
20/18 312 261 221 188 161 139 121 92 70 6x6 -
4 0.028
18/20 295 247 208 177 152 131 114 86 65 W1.4xW1.4
18/18 295 246 208 177 152 131 113 85 65
20/20 385 323 273 233 201 174 151 116 89
20/18 384 322 273 233 200 173 151 115 89 6x6 -
4 1/2 0.028
18/20 366 306 259 221 190 164 142 108 83 W1.4xW1.4
18/18 365 306 259 220 189 163 142 108 83
20/20 400 386 328 280 241 209 182 140 109
20/18 400 386 327 280 241 209 182 139 108 6x6 -
5 0.040
18/20 400 368 312 266 229 198 172 132 102 W2.0xW2.0
General Information
18/18 400 368 311 266 229 198 172 131 101
20/20 400 400 383 328 283 246 214 165 128
20/18 400 400 383 328 282 245 214 164 128 6x6 -
5 1/2 0.040
18/20 400 400 366 313 270 234 204 156 121 W2.0xW2.0
18/18 400 400 366 313 269 233 203 156 121
20/20 400 400 400 377 325 283 247 190 149
20/18 400 400 400 377 325 282 246 190 148 4x4 -
6 0.042
18/20 400 400 400 361 312 270 236 181 141 W1.4xW1.4
18/18 400 400 400 361 311 270 235 181 141
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
68 www.newmill.com/digital-tools
1.5CFDC Composite Floor Deck Cellular
Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 1.5CFDC Cellular
PROPERTIES 6˝ 2 21 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 1 21 ˝
18/16 0.0474/0.0598 5.17 1 85 ˝
16/18 0.0598/0.0474 24.5 5.25 24 21 ˝ Coverage
16/16 0.0598/0.0598 5.81
Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 3.102 0.607 0.607 0.594 0.554 0.458 0.583 13700 17444 3783 1913 3433
16/18 40 3.151 0.679 0.679 0.678 0.555 0.628 0.645 15035 15445 3798 2338 4234
16/16 40 3.486 0.739 0.739 0.738 0.655 0.648 0.712 15519 17042 3798 2338 4234
Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) 3 2 accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft /ft )
2. Web crippling design strengths* and maximum construction spans are
18/16 12 - 0 14 - 6 14 - 1 4 - 10
based on 1 1/2'' for end bearing and 3'' for interior bearing. Check web
Versa-Dek®
3 1/2 16/18 23 0.211
Long-Span Composite
12 - 4 13 - 7 14 - 1 4 - 8
crippling if minimums are not met.
16/16 12 - 7 14 - 3 14 - 9 4 - 11
3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
18/16 11 - 7 14 - 5 13 - 7 4 - 9
Lightweight Concrete (110 pcf)
Deep-Dek®
● Deck self-weight plus a 50 psf uniform construcon load, whichever
4 1/2 16/18 32 11 - 6 13 - 4 13 - 6 4 - 6 0.294
controls.
16/16 11 - 9 13 - 11 13 - 9 4 - 7
4. Concrete weights do not include weight of deck.
18/16 10 - 9 13 - 5 12 - 9 4 - 5
5. Deck profile has been accounted for in determining concrete
5 16/18 37 11 - 2 12 - 10 13 - 1 4 - 4 0.336
volumes. Deck and support deflections have not been included in
16/16 11 - 5 13 - 5 13 - 4 4 - 5
concrete volumes or weights.
18/16 10 - 5 12 - 11 12 - 5 4 - 3
5 1/2 16/18 42 0.377 6. Cantilever clear spans assume adjacent clear span is at least 3 times
10 - 9 12 - 5 12 - 9 4 - 3
16/16 longer than the cantilever clear span and no greater than spans
11 - 1 12 - 11 13 - 0 4 - 4
18/16 published above. Bearing width at perimeter support assumed to be 3''
10 - 1 12 - 5 12 - 2 4 - 1
Form Deck
6 16/18 46 0.419 minimum. Contact New Millennium otherwise.
10 - 5 12 - 0 12 - 4 4 - 1
16/16 10 - 9 12 - 6 12 - 9 4 - 3
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 69
1.5CFDC Composite Floor Deck Cellular
Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 1.5CFDC Cellular
PROPERTIES 6˝ 2 21 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 1 21 ˝
20/20 0.0358/0.0358 3.49 1 85 ˝
20/18 0.0358/0.0474
24.5
4.01 24 21 ˝ Coverage
18/20 0.0474/0.0358 4.09
Roof Deck
4 37 0.252
18/20 10 - 3 12 - 1 12 - 3 4 - 1 lb. concentrated load or a 20 psf uniform load; or
Deep-Dek®
Long-Span Composite
20/18 8 - 3 9 - 7 9 - 9 3 - 3 6. Cantilever clear spans assume adjacent clear span is at least 3 times
5 49 0.336
18/20 9 - 5 11 - 0 11 - 5 3 - 9 longer than the cantilever clear span and no greater than spans
18/18 9 - 8 12 - 0 11 - 9 4 - 0 published above. Bearing width at perimeter support assumed to be 3''
20/20 7 - 9 9 - 0 9 - 1 3 - 0 minimum. Contact New Millennium otherwise.
20/18 7 - 11 8 - 7 9 - 4 3 - 1
5 1/2 55 0.377
18/20 9 - 1 10 - 7 10 - 11 3 - 7
18/18 9 - 4 11 - 5 11 - 5 3 - 9
20/20 7 - 5 8 - 4 8 - 9 2 - 11
20/18 7 - 8 7 - 9 8 - 10 2 - 11
6 61 0.419
Form Deck
18/20 8 - 9 10 - 2 10 - 6 3 - 6
18/18 9 - 0 11 - 0 11 - 1 3 - 8
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in2/ft)
Normal-Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)
(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric
20/20 253 211 177 150 127 109 94 69 51
20/18 253 210 176 149 127 109 93 69 51 6x6 -
Typical Fastener Layouts
3 1/2 0.028
18/20 240 199 167 141 120 102 87 64 47 W1.4xW1.4
18/18 239 199 166 141 119 102 87 64 47
20/20 323 269 227 192 164 141 121 91 68
20/18 322 269 226 192 164 140 121 90 67 6x6 -
4 0.028
18/20 308 256 215 182 155 133 114 85 63 W1.4xW1.4
18/18 307 256 215 182 155 132 114 84 62
20/20 397 331 279 237 203 174 151 113 86
20/18 396 331 279 237 202 174 150 113 85 6x6 -
4 1/2 0.028
18/20 379 316 266 226 193 166 143 107 80 W1.4xW1.4
18/18 379 316 266 225 192 165 142 106 80
20/20 400 395 333 284 243 209 181 137 104
20/18 400 394 333 283 242 209 181 136 103 6x6 -
5 0.040
18/20 400 379 319 271 232 200 172 130 98 W2.0xW2.0
General Information
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
70 www.newmill.com/digital-tools
1.5CFDC Composite Floor Deck Cellular
Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 1.5CFDC Cellular
PROPERTIES 6˝ 2 21 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 1 21 ˝
18/16 0.0474/0.0598 5.17 1 85 ˝
16/18 0.0598/0.0474 24.5 5.25 24 21 ˝ Coverage
16/16 0.0598/0.0598 5.81
Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 3.102 0.607 0.607 0.594 0.554 0.458 0.583 13700 17444 3783 1913 3433
16/18 40 3.151 0.679 0.679 0.678 0.555 0.628 0.645 15035 15445 3798 2338 4234
16/16 40 3.486 0.739 0.739 0.738 0.655 0.648 0.712 15519 17042 3798 2338 4234
Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) 3 2 accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft /ft )
2. Web crippling design strengths* and maximum construction spans are
18/16 11 - 4 14 - 2 13 - 3 4 - 8
based on 1 1/2'' for end bearing and 3'' for interior bearing. Check web
Versa-Dek®
Long-Span Composite
3 1/2 16/18 31 11 - 8 13 - 7 13 - 8 4 - 6 0.211
crippling if minimums are not met.
16/16 11 - 10 14 - 2 13 - 11 4 - 8
Normal-Weight Concrete (145 pcf)
Deep-Dek®
● Deck self-weight plus a 50 psf uniform construcon load, whichever
4 1/2 16/18 43 10 - 8 12 - 3 12 - 8 4 - 2 0.294
controls.
16/16 11 - 0 12 - 10 12 - 11 4 - 3
4. Concrete weights do not include weight of deck.
18/16 9 - 11 12 - 2 12 - 0 4 - 0
5. Deck profile has been accounted for in determining concrete
5 16/18 49 10 - 3 11 - 9 12 - 2 4 - 0 0.336
volumes. Deck and support deflections have not been included in
16/16 10 - 7 12 - 3 12 - 7 4 - 2
concrete volumes or weights.
18/16 9 - 7 11 - 8 11 - 8 3 - 10
5 1/2 16/18 55 0.377 6. Cantilever clear spans assume adjacent clear span is at least 3 times
9 - 11 11 - 3 11 - 8 3 - 10
16/16 longer than the cantilever clear span and no greater than spans
10 - 2 11 - 10 12 - 3 4 - 1
18/16 published above. Bearing width at perimeter support assumed to be 3''
9 - 3 11 - 3 11 - 4 3 - 9
Form Deck
6 16/18 61 0.419 minimum. Contact New Millennium otherwise.
9 - 7 10 - 11 11 - 3 3 - 9
16/16 9 - 10 11 - 5 11 - 9 3 - 11
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 71
1.5CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 1.5CFDCA Cellular
PROPERTIES 6˝ 2 21 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 1 21 ˝
20/20 0.0358/0.0358 3.35 1 85 ˝
20/18 0.0358/0.0474
24.5
3.83 24 21 ˝ Coverage
18/20 0.0474/0.0358 3.95
Roof Deck
18/18 11 - 2 13 - 11 13 - 1 4 - 7 ● Deck self-weight and concrete weight plus worst-case of either a 150
20/20 9 - 1 10 - 8 10 - 9 3 - 7 lb. concentrated load or a 20 psf uniform load; or
20/18 9 - 5 11 - 0 11 - 1 3 - 8 ● Deck self-weight plus a 50 psf uniform construcon load, whichever
4 1/2 32 0.294
18/20 10 - 5 12 - 6 12 - 5 4 - 2 controls.
18/18 10 - 8 13 - 6 12 - 8 4 - 6 4. Concrete weights do not include weight of deck.
20/20 8 - 9 10 - 3 10 - 4 3 - 5 5. Deck profile has been accounted for in determining concrete
Versa-Dek®
20/18 9 - 0 10 - 6 10 - 8 3 - 6 volumes. Deck and support deflections have not been included in
5 37 0.336
18/20 10 - 0 12 - 0 12 - 1 4 - 0 concrete volumes or weights.
18/18 10 - 3 13 - 1 12 - 4 4 - 4 6. Cantilever clear spans assume adjacent clear span is at least 3 times
20/20 8 - 5 9 - 10 9 - 11 3 - 3 longer than the cantilever clear span and no greater than spans
20/18 8 - 8 10 - 2 10 - 3 3 - 5
5 1/2 42 0.377 published above. Bearing width at perimeter support assumed to be 3''
18/20 9 - 8 11 - 7 11 - 9 3 - 11
minimum. Contact New Millennium otherwise.
18/18 9 - 11 12 - 7 12 - 0 4 - 2
20/20 8 - 1 9 - 6 9 - 7 3 - 2
20/18 8 - 5 9 - 9 9 - 10 3 - 3
6 46 0.419
Form Deck
18/20 9 - 4 11 - 3 11 - 5 3 - 9
18/18 9 - 7 12 - 1 11 - 9 4 - 0
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric (in2/ft)
Lightweight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)
3 1/2 0.028
18/20 229 191 161 137 117 101 87 65 49 W1.4xW1.4
18/18 229 191 161 136 117 100 86 65 49
20/20 312 262 221 189 162 140 122 93 71
20/18 312 261 221 188 162 140 121 92 71 6x6 -
4 0.028
18/20 295 247 209 178 152 131 114 86 66 W1.4xW1.4
18/18 295 247 208 177 152 131 113 86 65
20/20 385 323 273 234 201 174 151 116 89
20/18 385 322 273 233 200 173 151 115 89 6x6 -
4 1/2 0.028
18/20 366 306 259 221 190 164 142 109 83 W1.4xW1.4
18/18 365 306 259 221 189 164 142 108 83
20/20 400 386 328 280 241 209 182 140 109
20/18 400 386 327 280 241 209 182 140 108 6x6 -
5 0.040
18/20 400 368 312 267 229 198 173 132 102 W2.0xW2.0
General Information
18/18 400 368 312 266 229 198 172 132 102
20/20 400 400 383 328 283 246 214 165 129
20/18 400 400 383 328 283 245 214 165 128 6x6 -
5 1/2 0.040
18/20 400 400 367 313 270 234 204 156 121 W2.0xW2.0
18/18 400 400 366 313 270 234 203 156 121
20/20 400 400 400 377 326 283 247 191 149
20/18 400 400 400 377 325 282 246 190 148 4x4 -
6 0.042
18/20 400 400 400 361 312 270 236 181 141 W1.4xW1.4
18/18 400 400 400 361 311 270 235 181 141
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
72 www.newmill.com/digital-tools
1.5CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 1.5CFDCA Cellular
PROPERTIES 6˝ 2 21 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 1 21 ˝
18/16 0.0474/0.0598 4.94 1 85 ˝
16/18 0.0598/0.0474 24.5 5.07 24 21 ˝ Coverage
16/16 0.0598/0.0598 5.58
Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 2.801 0.567 0.567 0.555 0.527 0.451 0.579 13488 17350 3783 1913 3433
16/18 40 2.913 0.631 0.631 0.631 0.542 0.617 0.642 14775 15379 3798 2338 4234
16/16 40 3.185 0.688 0.688 0.687 0.621 0.637 0.706 15259 16920 3798 2338 4234
Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) 3 2 accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft /ft )
accordance with SDI white paper ''Perforated Metal Deck Design with
18/16 11 - 10 14 - 6 13 - 10 4 - 10
Commentary''.
Versa-Dek®
Long-Span Composite
3 1/2 16/18 23 12 - 2 13 - 7 14 - 1 4 - 8 0.211
2. Web crippling design strengths* and maximum construction spans are
16/16 12 - 4 14 - 2 14 - 6 4 - 10
based on 1 1/2'' for end bearing and 3'' for interior bearing. Check web
18/16 11 - 5 14 - 2 13 - 4 4 - 8
Lightweight Concrete (110 pcf)
Deep-Dek®
● Deck self-weight and concrete weight plus worst-case of either a 150
4 1/2 16/18 32 11 - 4 13 - 4 13 - 3 4 - 5 0.294
lb. concentrated load or a 20 psf uniform load; or
16/16 11 - 6 13 - 11 13 - 6 4 - 7
● Deck self-weight plus a 50 psf uniform construcon load, whichever
18/16 10 - 6 13 - 4 12 - 7 4 - 5
controls.
5 16/18 37 10 - 11 12 - 10 12 - 11 4 - 3 0.336
4. Concrete weights do not include weight of deck.
16/16 11 - 2 13 - 5 13 - 1 4 - 5
5. Deck profile has been accounted for in determining concrete
18/16 10 - 2 12 - 10 12 - 3 4 - 3
5 1/2 16/18 42 0.377 volumes. Deck and support deflections have not been included in
10 - 6 12 - 4 12 - 7 4 - 2
16/16 concrete volumes or weights.
10 - 10 12 - 11 12 - 9 4 - 3
18/16 6. Cantilever clear spans assume adjacent clear span is at least 3 times
9 - 10 12 - 4 11 - 11 4 - 1
Form Deck
6 16/18 46 0.419 longer than the cantilever clear span and no greater than spans
10 - 3 12 - 0 12 - 3 4 - 1
16/16 published above. Bearing width at perimeter support assumed to be 3''
10 - 6 12 - 6 12 - 6 4 - 2
minimum. Contact New Millennium otherwise.
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 73
1.5CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 1.5CFDCA Cellular
PROPERTIES 6˝ 2 21 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 1 21 ˝
20/20 0.0358/0.0358 3.35 1 85 ˝
20/18 0.0358/0.0474
24.5
3.83 24 21 ˝ Coverage
18/20 0.0474/0.0358 3.95
Roof Deck
4 37 0.252
18/20 10 - 0 12 - 1 12 - 1 4 - 0 Composite Steel Floor Deck and the following construction loading:
Deep-Dek®
Long-Span Composite
18/18 10 - 4 13 - 2 12 - 4 4 - 4 ● Deck self-weight and concrete weight plus worst-case of either a 150
20/20 8 - 4 9 - 9 9 - 10 3 - 3 lb. concentrated load or a 20 psf uniform load; or
20/18 8 - 7 10 - 0 10 - 2 3 - 4 ● Deck self-weight plus a 50 psf uniform construcon load, whichever
4 1/2 43 0.294
18/20 9 - 7 11 - 6 11 - 8 3 - 10 controls.
18/18 9 - 10 12 - 5 11 - 11 4 - 1 4. Concrete weights do not include weight of deck.
20/20 8 - 0 9 - 3 9 - 5 3 - 1 5. Deck profile has been accounted for in determining concrete
Versa-Dek®
20/18 8 - 3 9 - 7 9 - 8 3 - 2 volumes. Deck and support deflections have not been included in
5 49 0.336
18/20 9 - 2 11 - 0 11 - 4 3 - 9 concrete volumes or weights.
18/18 9 - 5 11 - 10 11 - 7 3 - 11 6. Cantilever clear spans assume adjacent clear span is at least 3 times
20/20 7 - 8 8 - 11 9 - 0 3 - 0 longer than the cantilever clear span and no greater than spans
20/18 7 - 11 9 - 2 9 - 3 3 - 1
5 1/2 55 0.377 published above. Bearing width at perimeter support assumed to be 3''
18/20 8 - 10 10 - 7 10 - 11 3 - 7
minimum. Contact New Millennium otherwise.
18/18 9 - 1 11 - 4 11 - 3 3 - 9
20/20 7 - 4 8 - 7 8 - 8 2 - 10
20/18 7 - 7 8 - 5 8 - 11 2 - 11
6 61 0.419
Form Deck
18/20 8 - 7 10 - 2 10 - 6 3 - 6
18/18 8 - 10 10 - 11 10 - 11 3 - 7
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in2/ft)
Normal-Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)
(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric
20/20 253 211 177 150 128 109 94 69 52
20/18 253 210 177 149 127 109 93 69 51 6x6 -
Typical Fastener Layouts
3 1/2 0.028
18/20 240 199 167 141 120 102 87 64 47 W1.4xW1.4
18/18 239 199 167 141 119 102 87 64 47
20/20 323 269 227 192 164 141 121 91 68
20/18 323 269 226 192 164 141 121 90 68 6x6 -
4 0.028
18/20 308 256 215 182 155 133 114 85 63 W1.4xW1.4
18/18 307 256 215 182 155 133 114 84 63
20/20 397 331 279 237 203 175 151 113 86
20/18 396 331 279 237 203 174 150 113 85 6x6 -
4 1/2 0.028
18/20 379 316 266 226 193 166 143 107 80 W1.4xW1.4
18/18 379 316 266 226 193 165 142 106 80
20/20 400 395 333 284 243 209 181 137 104
20/18 400 395 333 283 243 209 181 136 104 6x6 -
5 0.040
18/20 400 379 319 272 232 200 172 130 98 W2.0xW2.0
General Information
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
74 www.newmill.com/digital-tools
1.5CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 1.5CFDCA Cellular
PROPERTIES 6˝ 2 21 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 1 21 ˝
18/16 0.0474/0.0598 4.94 1 85 ˝
16/18 0.0598/0.0474 24.5 5.07 24 21 ˝ Coverage
16/16 0.0598/0.0598 5.58
Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 2.801 0.567 0.567 0.555 0.527 0.451 0.579 13488 17350 3783 1913 3433
16/18 40 2.913 0.631 0.631 0.631 0.542 0.617 0.642 14775 15379 3798 2338 4234
16/16 40 3.185 0.688 0.688 0.687 0.621 0.637 0.706 15259 16920 3798 2338 4234
Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) 3 2 accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft /ft )
accordance with SDI white paper ''Perforated Metal Deck Design with
18/16 11 - 2 13 - 11 13 - 1 4 - 7
Commentary''.
Versa-Dek®
Long-Span Composite
3 1/2 16/18 31 11 - 5 13 - 6 13 - 5 4 - 6 0.211
2. Web crippling design strengths* and maximum construction spans are
16/16 11 - 8 14 - 2 13 - 8 4 - 8
Normal-Weight Concrete (145 pcf)
based on 1 1/2'' for end bearing and 3'' for interior bearing. Check web
18/16 10 - 7 13 - 4 12 - 7 4 - 5
crippling if minimums are not met.
4 16/18 37 10 - 11 12 - 10 12 - 11 4 - 3 0.252
3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
16/16 11 - 3 13 - 5 13 - 2 4 - 5
Composite Steel Floor Deck and the following construction loading:
18/16 10 - 1 12 - 8 12 - 2 4 - 2
Deep-Dek®
● Deck self-weight and concrete weight plus worst-case of either a 150
4 1/2 16/18 43 10 - 5 12 - 3 12 - 6 4 - 2 0.294
lb. concentrated load or a 20 psf uniform load; or
16/16 10 - 9 12 - 10 12 - 9 4 - 3
● Deck self-weight plus a 50 psf uniform construcon load, whichever
18/16 9 - 8 12 - 1 11 - 10 4 - 0
controls.
5 16/18 49 10 - 1 11 - 9 12 - 1 4 - 0 0.336
4. Concrete weights do not include weight of deck.
16/16 10 - 4 12 - 3 12 - 4 4 - 1
5. Deck profile has been accounted for in determining concrete
18/16 9 - 4 11 - 7 11 - 6 3 - 10
5 1/2 16/18 55 0.377 volumes. Deck and support deflections have not been included in
9 - 8 11 - 3 11 - 8 3 - 10
16/16 concrete volumes or weights.
9 - 11 11 - 9 12 - 0 4 - 0
18/16 6. Cantilever clear spans assume adjacent clear span is at least 3 times
9 - 1 11 - 2 11 - 2 3 - 8
Form Deck
6 16/18 61 0.419 longer than the cantilever clear span and no greater than spans
9 - 5 10 - 10 11 - 3 3 - 9
16/16 published above. Bearing width at perimeter support assumed to be 3''
9 - 8 11 - 4 11 - 9 3 - 11
minimum. Contact New Millennium otherwise.
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 75
2.0CFDC Composite Floor Deck Cellular
Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 2.0CFDC Cellular
PROPERTIES 5 81 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)
2˝
20/20 0.0358/0.0358 3.38 12˝ 5 81 ˝
20/18 0.0358/0.0474 3.92
24
18/20 0.0474/0.0358 3.95 24˝ Coverage
Roof Deck
20/18 10 - 1 11 - 6 11 - 10 3 - 11 6. Cantilever clear spans assume adjacent clear span is at least 3 times
5 1/2 41 0.375
18/20 11 - 6 12 - 9 13 - 1 4 - 4 longer than the cantilever clear span and no greater than spans
18/18 11 - 8 12 - 11 13 - 5 4 - 5 published above. Bearing width at perimeter support assumed to be 4''
20/20 9 - 7 10 - 9 11 - 1 3 - 8 minimum. Contact New Millennium otherwise.
20/18 9 - 9 11 - 1 11 - 5 3 - 9
6 46 0.417
18/20 11 - 3 12 - 4 12 - 7 4 - 2
18/18 11 - 5 12 - 6 13 - 0 4 - 4
20/20 9 - 3 10 - 5 10 - 9 3 - 7
20/18 9 - 5 10 - 9 11 - 0 3 - 8
6 1/2 50 0.458
Form Deck
18/20 10 - 11 11 - 11 12 - 3 4 - 1
18/18 11 - 2 12 - 2 12 - 6 4 - 2
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 7 - 0 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 Fabric (in2/ft)
Lightweight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)
4 0.028
18/20 332 247 215 189 147 116 92 74 59 W1.4xW1.4
18/18 332 246 215 188 146 115 92 73 59
20/20 309 229 198 173 134 104 82 65 51
20/18 309 228 198 173 133 104 81 64 50 6x6 -
4 1/2 0.028
18/20 400 301 262 230 180 142 114 92 74 W1.4xW1.4
18/18 400 300 262 230 179 142 113 91 73
20/20 368 272 236 207 160 125 99 78 62
20/18 367 271 236 206 159 124 98 78 61 6x6 -
5 0.028
18/20 400 358 313 275 215 170 137 110 90 W1.4xW1.4
18/18 400 358 312 274 214 170 136 110 89
20/20 400 317 276 241 187 147 116 92 74
20/18 400 317 275 241 186 146 116 92 73 6x6 -
5 1/2 0.040
18/20 400 400 365 321 251 200 161 130 106 W2.0xW2.0
General Information
18/18 400 400 365 321 251 199 160 130 106
20/20 400 364 317 277 215 169 134 107 86
20/18 400 363 316 276 215 169 134 107 85 6x6 -
6 0.040
18/20 400 400 400 369 289 230 186 151 123 W2.0xW2.0
18/18 400 400 400 368 289 230 185 150 123
20/20 400 400 358 314 244 192 153 122 98
20/18 400 400 358 313 243 192 152 122 98 4x4 -
6 1/2 0.042
18/20 400 400 400 400 328 262 211 172 141 W1.4xW1.4
18/18 400 400 400 400 328 261 211 171 140
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
76 www.newmill.com/digital-tools
2.0CFDC Composite Floor Deck Cellular
Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 2.0CFDC Cellular
PROPERTIES 5 81 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)
2˝
18/16 0.0474/0.0598 5.05 12˝ 5 81 ˝
16/18 0.0598/0.0474 24 5.08
16/16 0.0598/0.0598 5.66 24˝ Coverage
Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 2.969 0.940 0.940 0.939 0.819 0.571 0.585 17090 17522 3118 975 1867
16/18 40 2.984 1.050 1.050 1.048 0.877 0.737 0.694 17660 16611 3136 1191 2281
16/16 40 3.328 1.121 1.121 1.120 0.990 0.754 0.722 18070 17302 3136 1191 2281
Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft3/ft2)
2. Web crippling design strengths* and maximum construction spans are
18/16 12 - 11 14 - 6 15 - 0 5 - 0
based on 2'' for end bearing and 4'' for interior bearing. Check web
Versa-Dek®
Long-Span Composite
4 16/18 28 13 - 4 14 - 4 14 - 7 4 - 10 0.250
crippling if minimums are not met.
16/16 13 - 6 14 - 4 14 - 10 4 - 11
3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
18/16 12 - 6 14 - 3 14 - 8 4 - 10
Lightweight Concrete (110 pcf)
Deep-Dek®
● Deck self-weight plus a 50 psf uniform construcon load, whichever
5 16/18 37 12 - 6 13 - 6 13 - 9 4 - 7 0.333
controls.
16/16 12 - 8 13 - 6 14 - 0 4 - 8
4. Concrete weights do not include weight of deck.
18/16 11 - 10 13 - 2 13 - 8 4 - 6
5. Deck profile has been accounted for in determining concrete
5 1/2 16/18 41 12 - 2 13 - 0 13 - 3 4 - 5 0.375
volumes. Deck and support deflections have not been included in
16/16 12 - 4 13 - 1 13 - 6 4 - 6
concrete volumes or weights.
18/16 11 - 7 12 - 9 13 - 2 4 - 4
6 16/18 46 0.417 6. Cantilever clear spans assume adjacent clear span is at least 3 times
11 - 11 12 - 7 12 - 10 4 - 3
16/16 longer than the cantilever clear span and no greater than spans
12 - 1 12 - 7 13 - 0 4 - 4
18/16 published above. Bearing width at perimeter support assumed to be 4''
11 - 4 12 - 4 12 - 9 4 - 3
Form Deck
6 1/2 16/18 50 0.458 minimum. Contact New Millennium otherwise.
11 - 8 12 - 2 12 - 5 4 - 1
16/16 11 - 10 12 - 3 12 - 8 4 - 2
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 77
2.0CFDC Composite Floor Deck Cellular
Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 2.0CFDC Cellular
PROPERTIES 5 81 ˝
Gage Thickness Cover Weight
(Hat/Pan)
2˝
(in) (in) (psf)
20/20 0.0358/0.0358 3.38 12˝ 5 81 ˝
20/18 0.0358/0.0474 3.92
24
18/20 0.0474/0.0358 3.95 24˝ Coverage
Roof Deck
4 1/2 42 0.292
18/20 11 - 5 12 - 8 12 - 11 4 - 3 lb. concentrated load or a 20 psf uniform load; or
Deep-Dek®
Long-Span Composite
20/18 9 - 2 10 - 3 10 - 9 3 - 7 6. Cantilever clear spans assume adjacent clear span is at least 3 times
5 1/2 54 0.375
18/20 10 - 8 11 - 7 11 - 11 3 - 11 longer than the cantilever clear span and no greater than spans
18/18 10 - 11 11 - 10 12 - 3 4 - 1 published above. Bearing width at perimeter support assumed to be 4''
20/20 8 - 8 9 - 9 10 - 1 3 - 4 minimum. Contact New Millennium otherwise.
20/18 8 - 9 9 - 3 10 - 1 3 - 4
6 60 0.417
18/20 10 - 4 11 - 2 11 - 5 3 - 9
18/18 10 - 6 11 - 4 11 - 9 3 - 11
20/20 8 - 4 9 - 5 9 - 9 3 - 3
20/18 8 - 6 8 - 11 9 - 4 3 - 1
6 1/2 66 0.458
Form Deck
18/20 10 - 0 10 - 9 11 - 1 3 - 8
18/18 10 - 3 11 - 0 11 - 4 3 - 9
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in2/ft)
Normal-Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)
(in) 7 - 0 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 Fabric
20/20 260 190 163 142 107 82 62 47 35
20/18 259 189 163 141 107 81 62 47 35 6x6 -
Typical Fastener Layouts
4 0.028
18/20 343 254 220 192 148 115 90 71 56 W1.4xW1.4
18/18 343 253 219 191 147 115 90 71 55
20/20 315 231 199 173 131 101 77 59 45
20/18 315 230 199 172 131 100 77 58 44 6x6 -
4 1/2 0.028
18/20 400 309 268 234 181 141 111 88 70 W1.4xW1.4
18/18 400 308 268 234 180 141 111 88 69
20/20 374 274 237 206 157 121 93 72 55
20/18 373 274 236 205 156 120 93 71 54 6x6 -
5 0.028
18/20 400 367 319 279 216 169 134 106 85 W1.4xW1.4
18/18 400 366 318 278 215 169 133 106 84
20/20 400 319 276 240 183 142 110 85 65
20/18 400 319 276 239 183 141 109 84 65 6x6 -
5 1/2 0.040
18/20 400 400 372 325 252 198 157 125 100 W2.0xW2.0
General Information
18/18 400 400 371 325 252 198 157 125 100
20/20 400 365 316 275 211 163 127 99 76
20/18 400 365 316 275 210 163 126 98 76 6x6 -
6 0.040
18/20 400 400 400 373 290 228 182 145 116 W2.0xW2.0
18/18 400 400 400 372 289 228 181 145 116
20/20 400 400 357 311 239 185 144 113 88
20/18 400 400 357 311 238 185 144 112 87 4x4 -
6 1/2 0.042
18/20 400 400 400 400 328 259 206 165 133 W1.4xW1.4
18/18 400 400 400 400 328 258 206 165 132
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
78 www.newmill.com/digital-tools
2.0CFDC Composite Floor Deck Cellular
Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 2.0CFDC Cellular
PROPERTIES 5 81 ˝
Gage Thickness Cover Weight
(Hat/Pan)
2˝
(in) (in) (psf)
18/16 0.0474/0.0598 5.05 12˝ 5 81 ˝
16/18 0.0598/0.0474 24 5.08
16/16 0.0598/0.0598 5.66 24˝ Coverage
Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 2.969 0.940 0.940 0.939 0.819 0.571 0.585 17090 17522 3118 975 1867
16/18 40 2.984 1.050 1.050 1.048 0.877 0.737 0.694 17660 16611 3136 1191 2281
16/16 40 3.328 1.121 1.121 1.120 0.990 0.754 0.722 18070 17302 3136 1191 2281
Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft3/ft2)
2. Web crippling design strengths* and maximum construction spans are
18/16 12 - 2 13 - 9 14 - 2 4 - 8
based on 2'' for end bearing and 4'' for interior bearing. Check web
Versa-Dek®
Long-Span Composite
4 16/18 36 12 - 6 13 - 7 13 - 10 4 - 7 0.250
crippling if minimums are not met.
16/16 12 - 8 13 - 7 14 - 1 4 - 8
Normal-Weight Concrete (145 pcf)
Deep-Dek®
● Deck self-weight plus a 50 psf uniform construcon load, whichever
5 16/18 48 11 - 9 12 - 4 12 - 7 4 - 2 0.333
controls.
16/16 11 - 11 12 - 5 12 - 10 4 - 3
4. Concrete weights do not include weight of deck.
18/16 11 - 1 12 - 0 12 - 5 4 - 1
5. Deck profile has been accounted for in determining concrete
5 1/2 16/18 54 11 - 5 11 - 10 12 - 1 4 - 0 0.375
volumes. Deck and support deflections have not been included in
16/16 11 - 7 11 - 11 12 - 4 4 - 1
concrete volumes or weights.
18/16 10 - 9 11 - 7 12 - 0 4 - 0
6 16/18 60 0.417 6. Cantilever clear spans assume adjacent clear span is at least 3 times
11 - 2 11 - 5 11 - 9 3 - 11
16/16 longer than the cantilever clear span and no greater than spans
11 - 4 11 - 6 11 - 11 3 - 11
18/16 published above. Bearing width at perimeter support assumed to be 4''
10 - 5 11 - 2 11 - 7 3 - 10
Form Deck
6 1/2 16/18 66 0.458 minimum. Contact New Millennium otherwise.
10 - 10 11 - 0 11 - 4 3 - 9
16/16 11 - 0 11 - 1 11 - 5 3 - 9
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 79
2.0CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 2.0CFDCA Cellular
PROPERTIES 5 81 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)
2˝
20/20 0.0358/0.0358 3.25 12˝ 5 81 ˝
20/18 0.0358/0.0474 3.72
24
18/20 0.0474/0.0358 3.82 24˝ Coverage
Roof Deck
18/18 12 - 3 13 - 11 14 - 4 4 - 9 ● Deck self-weight and concrete weight plus worst-case of either a 150
20/20 10 - 3 11 - 6 11 - 11 3 - 11 lb. concentrated load or a 20 psf uniform load; or
20/18 10 - 5 11 - 10 12 - 3 4 - 1 ● Deck self-weight plus a 50 psf uniform construcon load, whichever
5 37 0.333
18/20 11 - 8 13 - 3 13 - 6 4 - 6 controls.
18/18 11 - 10 13 - 5 13 - 10 4 - 7 4. Concrete weights do not include weight of deck.
20/20 9 - 10 11 - 1 11 - 5 3 - 9 5. Deck profile has been accounted for in determining concrete
Versa-Dek®
20/18 10 - 0 11 - 5 11 - 9 3 - 11 volumes. Deck and support deflections have not been included in
5 1/2 41 0.375
18/20 11 - 4 12 - 9 13 - 0 4 - 4 concrete volumes or weights.
18/18 11 - 7 12 - 11 13 - 4 4 - 5 6. Cantilever clear spans assume adjacent clear span is at least 3 times
20/20 9 - 6 10 - 8 11 - 1 3 - 8 longer than the cantilever clear span and no greater than spans
20/18 9 - 8 11 - 1 11 - 4 3 - 9
6 46 0.417 published above. Bearing width at perimeter support assumed to be 4''
18/20 11 - 1 12 - 4 12 - 6 4 - 2
minimum. Contact New Millennium otherwise.
18/18 11 - 3 12 - 6 12 - 11 4 - 3
20/20 9 - 2 10 - 4 10 - 8 3 - 6
20/18 9 - 4 10 - 8 11 - 0 3 - 8
6 1/2 50 0.458
Form Deck
18/20 10 - 9 11 - 11 12 - 2 4 - 0
18/18 11 - 0 12 - 1 12 - 6 4 - 2
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 7 - 0 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 Fabric (in2/ft)
Lightweight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)
4 0.028
18/20 332 247 215 189 147 116 92 74 59 W1.4xW1.4
18/18 332 247 215 188 146 115 92 74 59
20/20 310 229 199 173 134 104 82 65 51
20/18 309 228 198 173 133 104 82 64 50 6x6 -
4 1/2 0.028
18/20 400 301 263 230 180 142 114 92 74 W1.4xW1.4
18/18 400 301 262 230 179 142 113 91 74
20/20 368 272 237 207 160 125 99 78 62
20/18 367 272 236 206 159 125 98 78 62 6x6 -
5 0.028
18/20 400 359 313 275 215 171 137 111 90 W1.4xW1.4
18/18 400 358 312 274 214 170 136 110 89
20/20 400 317 276 241 187 147 116 93 74
20/18 400 317 276 241 187 146 116 92 73 6x6 -
5 1/2 0.040
18/20 400 400 366 321 252 200 161 130 106 W2.0xW2.0
General Information
18/18 400 400 365 321 251 200 160 130 106
20/20 400 364 317 277 215 169 134 107 86
20/18 400 363 316 277 215 169 134 107 85 6x6 -
6 0.040
18/20 400 400 400 369 289 231 186 151 123 W2.0xW2.0
18/18 400 400 400 369 289 230 185 151 123
20/20 400 400 358 314 244 192 153 122 98
20/18 400 400 358 313 243 192 153 122 98 4x4 -
6 1/2 0.042
18/20 400 400 400 400 328 262 211 172 141 W1.4xW1.4
18/18 400 400 400 400 328 261 211 172 140
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
80 www.newmill.com/digital-tools
2.0CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 2.0CFDCA Cellular
PROPERTIES 5 81 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 2˝
18/16 0.0474/0.0598 4.80 12˝ 5 81 ˝
16/18 0.0598/0.0474 24 4.90
16/16 0.0598/0.0598 5.41 24˝ Coverage
Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 2.672 0.891 0.891 0.890 0.770 0.563 0.577 16867 17283 3118 975 1867
16/18 40 2.763 0.997 0.997 0.996 0.844 0.728 0.689 17429 16502 3136 1191 2281
16/16 40 3.031 1.062 1.062 1.060 0.931 0.744 0.712 17819 17057 3136 1191 2281
Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft3/ft2)
accordance with SDI white paper ''Perforated Metal Deck Design with
18/16 12 - 10 14 - 5 14 - 11 4 - 11
Commentary''.
Versa-Dek®
Long-Span Composite
4 16/18 28 13 - 2 14 - 4 14 - 7 4 - 10 0.250
2. Web crippling design strengths* and maximum construction spans are
16/16 13 - 4 14 - 4 14 - 9 4 - 11
based on 2'' for end bearing and 4'' for interior bearing. Check web
18/16 12 - 4 14 - 2 14 - 6 4 - 10
Lightweight Concrete (110 pcf)
Deep-Dek®
● Deck self-weight and concrete weight plus worst-case of either a 150
5 16/18 37 12 - 4 13 - 6 13 - 9 4 - 7 0.333
lb. concentrated load or a 20 psf uniform load; or
16/16 12 - 6 13 - 6 13 - 11 4 - 7
● Deck self-weight plus a 50 psf uniform construcon load, whichever
18/16 11 - 8 13 - 1 13 - 7 4 - 6
controls.
5 1/2 16/18 41 12 - 0 13 - 0 13 - 3 4 - 5 0.375
4. Concrete weights do not include weight of deck.
16/16 12 - 2 13 - 0 13 - 5 4 - 5
5. Deck profile has been accounted for in determining concrete
18/16 11 - 5 12 - 8 13 - 1 4 - 4
6 16/18 46 0.417 volumes. Deck and support deflections have not been included in
11 - 9 12 - 7 12 - 10 4 - 3
16/16 concrete volumes or weights.
11 - 11 12 - 7 13 - 0 4 - 4
18/16 6. Cantilever clear spans assume adjacent clear span is at least 3 times
11 - 2 12 - 3 12 - 8 4 - 2
Form Deck
6 1/2 16/18 50 0.458 longer than the cantilever clear span and no greater than spans
11 - 6 12 - 2 12 - 5 4 - 1
16/16 published above. Bearing width at perimeter support assumed to be 4''
11 - 8 12 - 2 12 - 7 4 - 2
minimum. Contact New Millennium otherwise.
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 81
2.0CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 2.0CFDCA Cellular
PROPERTIES 5 81 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)
2˝
20/20 0.0358/0.0358 3.25 12˝ 5 81 ˝
20/18 0.0358/0.0474 3.72
24
18/20 0.0474/0.0358 3.82 24˝ Coverage
Roof Deck
4 1/2 42 0.292
18/20 11 - 4 12 - 8 12 - 10 4 - 3 Composite Steel Floor Deck and the following construction loading:
Deep-Dek®
Long-Span Composite
18/18 11 - 6 12 - 10 13 - 3 4 - 5 ● Deck self-weight and concrete weight plus worst-case of either a 150
20/20 9 - 4 10 - 6 10 - 10 3 - 7 lb. concentrated load or a 20 psf uniform load; or
20/18 9 - 6 10 - 10 11 - 2 3 - 8 ● Deck self-weight plus a 50 psf uniform construcon load, whichever
5 48 0.333
18/20 10 - 11 12 - 1 12 - 4 4 - 1 controls.
18/18 11 - 1 12 - 3 12 - 8 4 - 2 4. Concrete weights do not include weight of deck.
20/20 8 - 11 10 - 1 10 - 5 3 - 5 5. Deck profile has been accounted for in determining concrete
Versa-Dek®
20/18 9 - 1 10 - 5 10 - 8 3 - 6 volumes. Deck and support deflections have not been included in
5 1/2 54 0.375
18/20 10 - 6 11 - 7 11 - 10 3 - 11 concrete volumes or weights.
18/18 10 - 9 11 - 9 12 - 2 4 - 0 6. Cantilever clear spans assume adjacent clear span is at least 3 times
20/20 8 - 7 9 - 8 10 - 0 3 - 4 longer than the cantilever clear span and no greater than spans
20/18 8 - 9 10 - 0 10 - 3 3 - 5
6 60 0.417 published above. Bearing width at perimeter support assumed to be 4''
18/20 10 - 2 11 - 2 11 - 4 3 - 9
minimum. Contact New Millennium otherwise.
18/18 10 - 4 11 - 4 11 - 9 3 - 11
20/20 8 - 3 9 - 4 9 - 8 3 - 2
20/18 8 - 5 9 - 4 9 - 11 3 - 3
6 1/2 66 0.458
Form Deck
18/20 9 - 10 10 - 9 11 - 0 3 - 8
18/18 10 - 1 10 - 11 11 - 4 3 - 9
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in2/ft)
Normal-Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)
(in) 7 - 0 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 Fabric
20/20 260 190 164 142 107 82 62 47 35
20/18 259 189 163 141 107 81 62 47 35 6x6 -
Typical Fastener Layouts
4 0.028
18/20 344 254 220 192 148 115 90 71 56 W1.4xW1.4
18/18 343 253 220 192 147 115 90 71 55
20/20 316 231 199 173 131 101 77 59 45
20/18 315 230 199 172 131 100 77 59 44 6x6 -
4 1/2 0.028
18/20 400 309 268 234 181 142 112 88 70 W1.4xW1.4
18/18 400 308 268 234 180 141 111 88 69
20/20 374 274 237 206 157 121 93 72 55
20/18 374 274 237 205 157 120 93 71 54 6x6 -
5 0.028
18/20 400 367 319 279 216 169 134 106 85 W1.4xW1.4
18/18 400 366 318 278 215 169 134 106 84
20/20 400 319 276 240 184 142 110 85 65
20/18 400 319 276 240 183 141 109 85 65 6x6 -
5 1/2 0.040
18/20 400 400 372 325 252 198 157 126 100 W2.0xW2.0
General Information
18/18 400 400 371 325 252 198 157 125 100
20/20 400 365 316 275 211 163 127 99 76
20/18 400 365 316 275 210 163 127 98 76 6x6 -
6 0.040
18/20 400 400 400 373 290 228 182 145 116 W2.0xW2.0
18/18 400 400 400 372 289 228 181 145 116
20/20 400 400 357 311 239 185 145 113 88
20/18 400 400 357 311 238 185 144 112 87 4x4 -
6 1/2 0.042
18/20 400 400 400 400 328 259 206 166 133 W1.4xW1.4
18/18 400 400 400 400 328 259 206 165 133
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
82 www.newmill.com/digital-tools
2.0CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 2.0CFDCA Cellular
PROPERTIES 5 81 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 2˝
18/16 0.0474/0.0598 4.80 12˝ 5 81 ˝
16/18 0.0598/0.0474 24 4.90
16/16 0.0598/0.0598 5.41 24˝ Coverage
Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 2.672 0.891 0.891 0.890 0.770 0.563 0.577 16867 17283 3118 975 1867
16/18 40 2.763 0.997 0.997 0.996 0.844 0.728 0.689 17429 16502 3136 1191 2281
16/16 40 3.031 1.062 1.062 1.060 0.931 0.744 0.712 17819 17057 3136 1191 2281
Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft3/ft2)
accordance with SDI white paper ''Perforated Metal Deck Design with
18/16 12 - 1 13 - 8 14 - 2 4 - 8
Commentary''.
Versa-Dek®
Long-Span Composite
4 16/18 36 12 - 5 13 - 7 13 - 10 4 - 7 0.250
2. Web crippling design strengths* and maximum construction spans are
16/16 12 - 6 13 - 7 14 - 0 4 - 8
Normal-Weight Concrete (145 pcf)
based on 2'' for end bearing and 4'' for interior bearing. Check web
18/16 11 - 8 13 - 0 13 - 6 4 - 6
crippling if minimums are not met.
4 1/2 16/18 42 12 - 0 12 - 11 13 - 2 4 - 4 0.292
3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
16/16 12 - 1 12 - 11 13 - 4 4 - 5
Composite Steel Floor Deck and the following construction loading:
18/16 11 - 3 12 - 5 12 - 11 4 - 3
Deep-Dek®
● Deck self-weight and concrete weight plus worst-case of either a 150
5 16/18 48 11 - 7 12 - 4 12 - 7 4 - 2 0.333
lb. concentrated load or a 20 psf uniform load; or
16/16 11 - 9 12 - 4 12 - 9 4 - 3
● Deck self-weight plus a 50 psf uniform construcon load, whichever
18/16 10 - 11 12 - 0 12 - 5 4 - 1
controls.
5 1/2 16/18 54 11 - 4 11 - 10 12 - 1 4 - 0 0.375
4. Concrete weights do not include weight of deck.
16/16 11 - 5 11 - 10 12 - 3 4 - 1
5. Deck profile has been accounted for in determining concrete
18/16 10 - 7 11 - 6 11 - 11 3 - 11
6 16/18 60 0.417 volumes. Deck and support deflections have not been included in
11 - 0 11 - 5 11 - 9 3 - 11
16/16 concrete volumes or weights.
11 - 2 11 - 5 11 - 10 3 - 11
18/16 6. Cantilever clear spans assume adjacent clear span is at least 3 times
10 - 3 11 - 2 11 - 6 3 - 10
Form Deck
6 1/2 16/18 66 0.458 longer than the cantilever clear span and no greater than spans
10 - 8 11 - 0 11 - 4 3 - 9
16/16 published above. Bearing width at perimeter support assumed to be 4''
10 - 10 11 - 0 11 - 5 3 - 9
minimum. Contact New Millennium otherwise.
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 83
3.0CFDC Composite Floor Deck Cellular
Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 3.0CFDC Cellular
PROPERTIES 5˝
Gage Thickness Cover Weight 3˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 3.58 12˝ 5˝
20/18 0.0358/0.0474 4.12
24
18/20 0.0474/0.0358 4.21 24˝ Coverage
Roof Deck
20/18 12 - 8 13 - 9 14 - 3 4 - 9 6. Cantilever clear spans assume adjacent clear span is at least 3 times
6 1/2 46 0.417
18/20 13 - 10 15 - 6 15 - 10 5 - 3 longer than the cantilever clear span and no greater than spans
18/18 14 - 1 15 - 9 16 - 3 5 - 5 published above. Bearing width at perimeter support assumed to be 5''
20/20 11 - 11 12 - 11 13 - 4 4 - 5 minimum. Contact New Millennium otherwise.
20/18 12 - 3 13 - 4 13 - 9 4 - 7
7 50 0.458
18/20 13 - 7 15 - 0 15 - 4 5 - 1
18/18 13 - 9 15 - 3 15 - 9 5 - 3
20/20 11 - 6 12 - 6 12 - 11 4 - 3
20/18 11 - 10 12 - 7 13 - 4 4 - 5
7 1/2 55 0.500
Form Deck
18/20 13 - 4 14 - 6 14 - 10 4 - 11
18/18 13 - 6 14 - 9 15 - 3 5 - 1
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0 16 - 0 Fabric (in2/ft)
Lightweight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)
5 0.028
18/20 400 328 259 208 168 132 106 86 71 W1.4xW1.4
18/18 400 328 258 207 168 132 106 86 71
20/20 381 292 229 182 147 119 97 80 65
20/18 380 292 229 182 146 119 97 79 64 6x6 -
5 1/2 0.028
18/20 400 384 303 244 198 163 135 112 92 W1.4xW1.4
18/18 400 384 303 243 198 162 134 112 92
20/20 400 338 265 212 171 139 113 93 76
20/18 400 338 265 211 170 138 113 93 76 6x6 -
6 0.028
18/20 400 400 351 282 230 189 157 131 110 W1.4xW1.4
18/18 400 400 351 282 230 189 156 130 109
20/20 400 386 304 242 196 159 131 108 88
20/18 400 386 303 242 195 159 130 107 88 6x6 -
6 1/2 0.040
18/20 400 400 400 323 264 217 181 151 126 W2.0xW2.0
General Information
18/18 400 400 400 323 263 217 180 150 126
20/20 400 400 343 274 222 181 149 123 101
20/18 400 400 343 274 221 181 148 122 101 6x6 -
7 0.040
18/20 400 400 400 366 299 247 205 172 144 W2.0xW2.0
18/18 400 400 400 366 298 246 205 171 144
20/20 400 400 384 307 249 203 167 138 114
20/18 400 400 384 307 248 203 167 138 114 4x4 -
7 1/2 0.042
18/20 400 400 400 400 335 277 231 193 163 W1.4xW1.4
18/18 400 400 400 400 335 276 230 193 162
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
84 www.newmill.com/digital-tools
3.0CFDC Composite Floor Deck Cellular
Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 3.0CFDC Cellular
PROPERTIES 5˝
Gage Thickness Cover Weight 3˝
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 5.32 12˝ 5˝
16/18 0.0598/0.0474 24 5.41
16/16 0.0598/0.0598 6.00 24˝ Coverage
Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 3.125 2.167 2.167 2.166 1.887 0.883 0.914 26446 27359 4491 1049 2079
16/18 40 3.180 2.441 2.441 2.440 2.048 1.169 1.097 27991 26278 4848 1285 2537
16/16 40 3.524 2.594 2.594 2.593 2.289 1.189 1.136 28485 27206 4848 1285 2537
Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft3/ft2)
2. Web crippling design strengths* and maximum construction spans are
18/16 15 - 5 17 - 9 18 - 1 6 - 0
based on 2 1/2'' for end bearing and 5'' for interior bearing. Check web
Versa-Dek®
Long-Span Composite
5 16/18 32 15 - 10 17 - 7 18 - 0 6 - 0 0.292
crippling if minimums are not met.
16/16 16 - 1 17 - 8 18 - 3 6 - 1
3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
18/16 15 - 0 17 - 1 17 - 7 5 - 10
Lightweight Concrete (110 pcf)
Deep-Dek®
● Deck self-weight plus a 50 psf uniform construcon load, whichever
6 16/18 41 15 - 0 16 - 4 16 - 9 5 - 7 0.375
controls.
16/16 15 - 2 16 - 4 16 - 11 5 - 7
4. Concrete weights do not include weight of deck.
18/16 14 - 3 15 - 11 16 - 6 5 - 6
5. Deck profile has been accounted for in determining concrete
6 1/2 16/18 46 14 - 8 15 - 9 16 - 2 5 - 4 0.417
volumes. Deck and support deflections have not been included in
16/16 14 - 10 15 - 10 16 - 5 5 - 5
concrete volumes or weights.
18/16 13 - 11 15 - 5 16 - 0 5 - 4
7 16/18 50 0.458 6. Cantilever clear spans assume adjacent clear span is at least 3 times
14 - 4 15 - 3 15 - 8 5 - 2
16/16 longer than the cantilever clear span and no greater than spans
14 - 6 15 - 4 15 - 11 5 - 3
18/16 published above. Bearing width at perimeter support assumed to be 5''
13 - 8 15 - 0 15 - 6 5 - 2
Form Deck
7 1/2 16/18 55 0.500 minimum. Contact New Millennium otherwise.
14 - 1 14 - 10 15 - 3 5 - 1
16/16 14 - 3 14 - 11 15 - 5 5 - 1
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 85
3.0CFDC Composite Floor Deck Cellular
Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 3.0CFDC Cellular
PROPERTIES 5˝
Gage Thickness Cover Weight 3˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 3.58 12˝ 5˝
20/18 0.0358/0.0474 4.12
24
18/20 0.0474/0.0358 4.21 24˝ Coverage
Roof Deck
5 1/2 48 0.333
18/20 13 - 8 15 - 2 15 - 6 5 - 2 lb. concentrated load or a 20 psf uniform load; or
Deep-Dek®
Long-Span Composite
20/18 11 - 5 11 - 9 12 - 11 4 - 3 6. Cantilever clear spans assume adjacent clear span is at least 3 times
6 1/2 60 0.417
18/20 13 - 0 14 - 0 14 - 4 4 - 9 longer than the cantilever clear span and no greater than spans
18/18 13 - 2 14 - 3 14 - 9 4 - 11 published above. Bearing width at perimeter support assumed to be 5''
20/20 10 - 8 11 - 2 12 - 1 4 - 0 minimum. Contact New Millennium otherwise.
20/18 11 - 0 11 - 2 12 - 5 4 - 1
7 66 0.458
18/20 12 - 9 13 - 6 13 - 10 4 - 7
18/18 12 - 11 13 - 10 14 - 3 4 - 9
20/20 10 - 4 10 - 6 11 - 8 3 - 10
20/18 10 - 7 10 - 6 11 - 8 3 - 10
7 1/2 73 0.500
Form Deck
18/20 12 - 6 13 - 1 13 - 5 4 - 5
18/18 12 - 8 13 - 4 13 - 10 4 - 7
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in2/ft)
Normal-Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)
(in) 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0 16 - 0 Fabric
20/20 332 252 196 154 122 97 77 61 48
20/18 331 252 195 153 121 96 77 61 48 6x6 -
Typical Fastener Layouts
5 0.028
18/20 400 336 264 210 169 137 112 91 75 W1.4xW1.4
18/18 400 336 263 209 168 136 111 91 74
20/20 388 296 230 181 144 115 92 73 58
20/18 388 295 229 180 143 114 91 73 58 6x6 -
5 1/2 0.028
18/20 400 394 309 246 199 162 132 108 89 W1.4xW1.4
18/18 400 394 309 246 198 161 132 108 88
20/20 400 342 266 210 167 134 107 86 69
20/18 400 342 266 209 167 133 107 86 68 6x6 -
6 0.028
18/20 400 400 358 286 231 188 154 127 104 W1.4xW1.4
18/18 400 400 357 285 230 187 153 126 104
20/20 400 390 304 240 192 154 124 100 80
20/18 400 390 304 240 191 153 123 99 79 6x6 -
6 1/2 0.040
18/20 400 400 400 327 264 216 177 146 120 W2.0xW2.0
General Information
18/18 400 400 400 326 264 215 177 145 120
20/20 400 400 343 272 217 175 141 114 91
20/18 400 400 343 271 217 174 140 113 91 6x6 -
7 0.040
18/20 400 400 400 370 299 245 201 166 137 W2.0xW2.0
18/18 400 400 400 369 299 244 201 166 137
20/20 400 400 384 304 243 196 159 128 104
20/18 400 400 383 304 243 196 158 128 103 4x4 -
7 1/2 0.042
18/20 400 400 400 400 335 274 226 187 155 W1.4xW1.4
18/18 400 400 400 400 335 274 225 186 155
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
86 www.newmill.com/digital-tools
3.0CFDC Composite Floor Deck Cellular
Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 3.0CFDC Cellular
PROPERTIES 5˝
Gage Thickness Cover Weight 3˝
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 5.32 12˝ 5˝
16/18 0.0598/0.0474 24 5.41
16/16 0.0598/0.0598 6.00 24˝ Coverage
Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 3.125 2.167 2.167 2.166 1.887 0.883 0.914 26446 27359 4491 1049 2079
16/18 40 3.180 2.441 2.441 2.440 2.048 1.169 1.097 27991 26278 4848 1285 2537
16/16 40 3.524 2.594 2.594 2.593 2.289 1.189 1.136 28485 27206 4848 1285 2537
Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft3/ft2)
2. Web crippling design strengths* and maximum construction spans are
18/16 14 - 6 16 - 4 16 - 11 5 - 7
based on 2 1/2'' for end bearing and 5'' for interior bearing. Check web
Versa-Dek®
Long-Span Composite
5 16/18 42 14 - 11 16 - 2 16 - 7 5 - 6 0.292
crippling if minimums are not met.
16/16 15 - 1 16 - 3 16 - 10 5 - 7
Normal-Weight Concrete (145 pcf)
Deep-Dek®
● Deck self-weight plus a 50 psf uniform construcon load, whichever
6 16/18 54 14 - 1 14 - 10 15 - 3 5 - 1 0.375
controls.
16/16 14 - 4 15 - 0 15 - 6 5 - 2
4. Concrete weights do not include weight of deck.
18/16 13 - 5 14 - 6 15 - 0 5 - 0
5. Deck profile has been accounted for in determining concrete
6 1/2 16/18 60 13 - 9 14 - 4 14 - 9 4 - 11 0.417
volumes. Deck and support deflections have not been included in
16/16 13 - 11 14 - 5 14 - 11 4 - 11
concrete volumes or weights.
18/16 13 - 1 14 - 0 14 - 6 4 - 10
7 16/18 66 0.458 6. Cantilever clear spans assume adjacent clear span is at least 3 times
13 - 6 13 - 10 14 - 3 4 - 9
16/16 longer than the cantilever clear span and no greater than spans
13 - 8 13 - 11 14 - 5 4 - 9
18/16 published above. Bearing width at perimeter support assumed to be 5''
12 - 10 13 - 7 14 - 0 4 - 8
Form Deck
7 1/2 16/18 73 0.500 minimum. Contact New Millennium otherwise.
13 - 2 13 - 4 13 - 10 4 - 7
16/16 13 - 5 13 - 6 14 - 0 4 - 8
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 87
3.0CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 3.0CFDCA Cellular
PROPERTIES 5˝
Gage Thickness Cover Weight 3˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 3.45 12˝ 5˝
20/18 0.0358/0.0474 3.92
24
18/20 0.0474/0.0358 4.08 24˝ Coverage
Roof Deck
18/18 14 - 8 16 - 10 17 - 2 5 - 8 ● Deck self-weight and concrete weight plus worst-case of either a 150
20/20 12 - 10 13 - 9 14 - 3 4 - 9 lb. concentrated load or a 20 psf uniform load; or
20/18 12 - 10 14 - 3 14 - 8 4 - 10 ● Deck self-weight plus a 50 psf uniform construcon load, whichever
6 41 0.375
18/20 14 - 1 16 - 0 16 - 3 5 - 5 controls.
18/18 14 - 3 16 - 3 16 - 8 5 - 6 4. Concrete weights do not include weight of deck.
20/20 12 - 4 13 - 3 13 - 9 4 - 7 5. Deck profile has been accounted for in determining concrete
Versa-Dek®
20/18 12 - 4 13 - 9 14 - 2 4 - 8 volumes. Deck and support deflections have not been included in
6 1/2 46 0.417
18/20 13 - 9 15 - 6 15 - 8 5 - 2 concrete volumes or weights.
18/18 13 - 11 15 - 8 16 - 3 5 - 5 6. Cantilever clear spans assume adjacent clear span is at least 3 times
20/20 11 - 11 12 - 10 13 - 4 4 - 5 longer than the cantilever clear span and no greater than spans
20/18 11 - 11 13 - 3 13 - 9 4 - 7
7 50 0.458 published above. Bearing width at perimeter support assumed to be 5''
18/20 13 - 5 15 - 0 15 - 2 5 - 0
minimum. Contact New Millennium otherwise.
18/18 13 - 7 15 - 2 15 - 8 5 - 2
20/20 11 - 6 12 - 6 12 - 11 4 - 3
20/18 11 - 6 12 - 7 13 - 4 4 - 5
7 1/2 55 0.500
Form Deck
18/20 13 - 2 14 - 6 14 - 9 4 - 11
18/18 13 - 4 14 - 9 15 - 3 5 - 1
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0 16 - 0 Fabric (in2/ft)
Lightweight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)
5 0.028
18/20 400 328 259 208 168 132 106 86 71 W1.4xW1.4
18/18 400 328 258 207 168 132 106 86 71
20/20 381 293 229 183 147 119 97 80 65
20/18 380 292 229 182 147 119 97 79 65 6x6 -
5 1/2 0.028
18/20 400 384 304 244 198 163 135 112 92 W1.4xW1.4
18/18 400 384 303 243 198 162 134 112 92
20/20 400 338 266 212 171 139 114 93 77
20/18 400 338 265 211 170 138 113 93 76 6x6 -
6 0.028
18/20 400 400 351 283 230 189 157 131 110 W1.4xW1.4
18/18 400 400 351 282 230 189 157 131 109
20/20 400 387 304 242 196 160 131 108 89
20/18 400 386 303 242 195 159 130 107 88 6x6 -
6 1/2 0.040
18/20 400 400 400 324 264 218 181 151 127 W2.0xW2.0
General Information
18/18 400 400 400 323 263 217 180 150 126
20/20 400 400 343 274 222 181 149 123 101
20/18 400 400 343 274 222 181 148 122 101 6x6 -
7 0.040
18/20 400 400 400 366 299 247 205 172 144 W2.0xW2.0
18/18 400 400 400 366 299 246 205 171 144
20/20 400 400 384 307 249 204 167 138 114
20/18 400 400 384 307 249 203 167 138 114 4x4 -
7 1/2 0.042
18/20 400 400 400 400 335 277 231 193 163 W1.4xW1.4
18/18 400 400 400 400 335 277 230 193 162
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
88 www.newmill.com/digital-tools
3.0CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 3.0CFDCA Cellular
PROPERTIES 5˝
Gage Thickness Cover Weight 3˝
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 5.07 12˝ 5˝
16/18 0.0598/0.0474 24 5.24
16/16 0.0598/0.0598 5.75 24˝ Coverage
Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 2.828 2.056 2.056 2.056 1.782 0.883 0.902 26424 26998 4491 1049 2079
16/18 40 2.960 2.324 2.324 2.323 1.979 1.153 1.090 27626 26114 4848 1285 2537
16/16 40 3.227 2.460 2.460 2.459 2.163 1.173 1.121 28089 26838 4848 1285 2537
Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft3/ft2)
accordance with SDI white paper ''Perforated Metal Deck Design with
18/16 15 - 3 17 - 8 17 - 10 5 - 11
Commentary''.
Versa-Dek®
Long-Span Composite
5 16/18 32 15 - 8 17 - 7 18 - 0 6 - 0 0.292
2. Web crippling design strengths* and maximum construction spans are
16/16 15 - 10 17 - 7 18 - 2 6 - 0
based on 2 1/2'' for end bearing and 5'' for interior bearing. Check web
18/16 14 - 10 17 - 0 17 - 4 5 - 9
Lightweight Concrete (110 pcf)
Deep-Dek®
● Deck self-weight and concrete weight plus worst-case of either a 150
6 16/18 41 14 - 10 16 - 4 16 - 8 5 - 6 0.375
lb. concentrated load or a 20 psf uniform load; or
16/16 15 - 0 16 - 4 16 - 10 5 - 7
● Deck self-weight plus a 50 psf uniform construcon load, whichever
18/16 14 - 1 15 - 10 16 - 5 5 - 5
controls.
6 1/2 16/18 46 14 - 6 15 - 9 16 - 2 5 - 4 0.417
4. Concrete weights do not include weight of deck.
16/16 14 - 8 15 - 9 16 - 4 5 - 5
5. Deck profile has been accounted for in determining concrete
18/16 13 - 9 15 - 4 15 - 11 5 - 3
7 16/18 50 0.458 volumes. Deck and support deflections have not been included in
14 - 2 15 - 3 15 - 8 5 - 2
16/16 concrete volumes or weights.
14 - 4 15 - 3 15 - 10 5 - 3
18/16 6. Cantilever clear spans assume adjacent clear span is at least 3 times
13 - 6 14 - 11 15 - 5 5 - 1
Form Deck
7 1/2 16/18 55 0.500 longer than the cantilever clear span and no greater than spans
13 - 11 14 - 10 15 - 2 5 - 0
16/16 published above. Bearing width at perimeter support assumed to be 5''
14 - 1 14 - 10 15 - 4 5 - 1
minimum. Contact New Millennium otherwise.
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 89
3.0CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 3.0CFDCA Cellular
PROPERTIES 5˝
Gage Thickness Cover Weight 3˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 3.45 12˝ 5˝
20/18 0.0358/0.0474 3.92
24
18/20 0.0474/0.0358 4.08 24˝ Coverage
Roof Deck
5 1/2 48 0.333
18/20 13 - 7 15 - 2 15 - 5 5 - 1 Composite Steel Floor Deck and the following construction loading:
Deep-Dek®
Long-Span Composite
18/18 13 - 9 15 - 5 15 - 11 5 - 3 ● Deck self-weight and concrete weight plus worst-case of either a 150
20/20 11 - 7 12 - 6 12 - 11 4 - 3 lb. concentrated load or a 20 psf uniform load; or
20/18 11 - 7 12 - 8 13 - 4 4 - 5 ● Deck self-weight plus a 50 psf uniform construcon load, whichever
6 54 0.375
18/20 13 - 2 14 - 7 14 - 10 4 - 11 controls.
18/18 13 - 4 14 - 9 15 - 4 5 - 1 4. Concrete weights do not include weight of deck.
20/20 11 - 2 11 - 10 12 - 6 4 - 2 5. Deck profile has been accounted for in determining concrete
Versa-Dek®
20/18 11 - 1 11 - 9 12 - 10 4 - 3 volumes. Deck and support deflections have not been included in
6 1/2 60 0.417
18/20 12 - 10 14 - 0 14 - 3 4 - 9 concrete volumes or weights.
18/18 13 - 1 14 - 3 14 - 9 4 - 11 6. Cantilever clear spans assume adjacent clear span is at least 3 times
20/20 10 - 9 11 - 2 12 - 0 4 - 0 longer than the cantilever clear span and no greater than spans
20/18 10 - 9 11 - 2 12 - 5 4 - 1
7 66 0.458 published above. Bearing width at perimeter support assumed to be 5''
18/20 12 - 7 13 - 6 13 - 9 4 - 7
minimum. Contact New Millennium otherwise.
18/18 12 - 9 13 - 9 14 - 3 4 - 9
20/20 10 - 4 10 - 6 11 - 7 3 - 10
20/18 10 - 4 10 - 6 11 - 8 3 - 10
7 1/2 73 0.500
Form Deck
18/20 12 - 4 13 - 1 13 - 5 4 - 5
18/18 12 - 6 13 - 4 13 - 9 4 - 7
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in2/ft)
Normal-Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)
(in) 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0 16 - 0 Fabric
20/20 332 252 196 154 122 97 77 62 49
20/18 331 252 195 153 122 97 77 61 48 6x6 -
Typical Fastener Layouts
5 0.028
18/20 400 336 264 210 169 137 112 91 75 W1.4xW1.4
18/18 400 336 263 209 168 137 111 91 74
20/20 388 296 230 181 144 115 92 73 58
20/18 388 295 229 181 143 114 91 73 58 6x6 -
5 1/2 0.028
18/20 400 394 309 247 199 162 132 108 89 W1.4xW1.4
18/18 400 394 309 246 198 161 132 108 88
20/20 400 342 266 210 167 134 107 86 69
20/18 400 342 266 209 167 133 107 86 68 6x6 -
6 0.028
18/20 400 400 358 286 231 188 154 127 104 W1.4xW1.4
18/18 400 400 358 285 230 188 154 126 104
20/20 400 391 304 240 192 154 124 100 80
20/18 400 390 304 240 191 153 123 99 79 6x6 -
6 1/2 0.040
18/20 400 400 400 327 264 216 177 146 121 W2.0xW2.0
General Information
18/18 400 400 400 326 264 215 177 146 120
20/20 400 400 344 272 217 175 141 114 92
20/18 400 400 343 271 217 174 141 113 91 6x6 -
7 0.040
18/20 400 400 400 370 299 245 201 166 138 W2.0xW2.0
18/18 400 400 400 369 299 244 201 166 137
20/20 400 400 384 304 243 196 159 128 104
20/18 400 400 384 304 243 196 158 128 103 4x4 -
7 1/2 0.042
18/20 400 400 400 400 335 274 226 187 155 W1.4xW1.4
18/18 400 400 400 400 335 274 226 187 155
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
90 www.newmill.com/digital-tools
3.0CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 3.0CFDCA Cellular
PROPERTIES 5˝
Gage Thickness Cover Weight 3˝
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 5.07 12˝ 5˝
16/18 0.0598/0.0474 24 5.24
16/16 0.0598/0.0598 5.75 24˝ Coverage
Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 2.828 2.056 2.056 2.056 1.782 0.883 0.902 26424 26998 4491 1049 2079
16/18 40 2.960 2.324 2.324 2.323 1.979 1.153 1.090 27626 26114 4848 1285 2537
16/16 40 3.227 2.460 2.460 2.459 2.163 1.173 1.121 28089 26838 4848 1285 2537
Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft3/ft2)
accordance with SDI white paper ''Perforated Metal Deck Design with
18/16 14 - 4 16 - 3 16 - 10 5 - 7
Commentary''.
Versa-Dek®
Long-Span Composite
5 16/18 42 14 - 9 16 - 2 16 - 7 5 - 6 0.292
2. Web crippling design strengths* and maximum construction spans are
16/16 14 - 11 16 - 2 16 - 9 5 - 7
Normal-Weight Concrete (145 pcf)
based on 2 1/2'' for end bearing and 5'' for interior bearing. Check web
18/16 13 - 11 15 - 7 16 - 1 5 - 4
crippling if minimums are not met.
5 1/2 16/18 48 14 - 4 15 - 6 15 - 10 5 - 3 0.333
3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
16/16 14 - 6 15 - 6 16 - 0 5 - 4
Composite Steel Floor Deck and the following construction loading:
18/16 13 - 6 15 - 0 15 - 6 5 - 2
Deep-Dek®
● Deck self-weight and concrete weight plus worst-case of either a 150
6 16/18 54 13 - 11 14 - 10 15 - 3 5 - 1 0.375
lb. concentrated load or a 20 psf uniform load; or
16/16 14 - 1 14 - 11 15 - 5 5 - 1
● Deck self-weight plus a 50 psf uniform construcon load, whichever
18/16 13 - 3 14 - 5 14 - 11 4 - 11
controls.
6 1/2 16/18 60 13 - 7 14 - 4 14 - 9 4 - 11 0.417
4. Concrete weights do not include weight of deck.
16/16 13 - 9 14 - 4 14 - 10 4 - 11
5. Deck profile has been accounted for in determining concrete
18/16 12 - 11 13 - 11 14 - 5 4 - 9
7 16/18 66 0.458 volumes. Deck and support deflections have not been included in
13 - 4 13 - 10 14 - 3 4 - 9
16/16 concrete volumes or weights.
13 - 6 13 - 10 14 - 4 4 - 9
18/16 6. Cantilever clear spans assume adjacent clear span is at least 3 times
12 - 8 13 - 6 13 - 11 4 - 7
Form Deck
7 1/2 16/18 73 0.500 longer than the cantilever clear span and no greater than spans
13 - 1 13 - 4 13 - 10 4 - 7
16/16 published above. Bearing width at perimeter support assumed to be 5''
13 - 3 13 - 5 13 - 11 4 - 7
minimum. Contact New Millennium otherwise.
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 91
Long-Span
Table of Contents
Composite Deck
Roof Deck
Versa-Dek® Composite
Versa-Dek® Composite is a versatile, long-span composite floor system, ideal for
multi-story construction. It’s ‘dovetail’ profiling keys to concrete to create a superior
Composite Deck
composite bond. Because more concrete is placed in the bottom of the deck, the
total slab thickness needed to achieve fire ratings is the shallowest available.
Deep-Dek®
Long-Span Composite
Versa-Dek®
8˝
6˝
3 21 ˝
2˝
Advantages
Space optimization
• Low-profile slabs as thin as 4-inches maximize
Typical Fastener Layouts
Roof Deck
Deep-Dek® Composite
Deep-Dek® Composite is our longest spanning composite floor option. It integrates
concrete and deep-ribbed deck profiles with custom side lap treatments to create
Composite Deck
a unique composite bond. The system is an excellent fit in structures demanding
combinations of shallow depth, high-load capacity and stringent serviceability demands.
Versa-Dek®
Long-Span Composite
Deep-Dek®
7 85 ˝ 7 85 ˝ 7 85 ˝
4 85 ˝ 4 85 ˝ 4 85 ˝ 6 18 ˝ 6 18 ˝ 6 18 ˝
12˝ Coverage
12˝ Coverage
12˝ Coverage 12˝ Coverage
12˝ Coverage
12˝ Coverage 12˝ Coverage
12˝ Coverage
12˝ Coverage
Form Deck
Deep-Dek® Composite 4.5 Deep-Dek® Composite 6.0 Deep-Dek® Composite 7.5
Advantages
Space optimization
93
Long-Span Composite
Code of Standard Practice General Information Typical Fastener Layouts Form Deck Composite Deck Roof Deck Table of Contents
Versa-Dek® Deep-Dek®
Form Deck
Table of Contents
Form deck is used extensively in floor construction as an economical form
to support concrete slabs during construction. Certain deck types may
eliminate the need for expensive temporary shoring. Click on the links
below to view load tables.
Roof Deck
0.6 and 1.0 Form Deck................................................................................... 96 – 99
Composite Deck
9/16-inch and 1-inch form deck,
standard and vented options available
EHD-Dek...........................................................................................................100 – 101
1 5/16-inch form deck, standard
and vented options available
Versa-Dek®
Long-Span Composite
1.5 Form Deck............................................................................................... 102 – 105
1.5-inch form deck with standard,
Deep-Dek®
interlocking, and vented options available
Form Deck
3.0 Form Deck............................................................................................... 108 – 109
3-inch form deck
newmill.com 95
0.6FD, 0.6FDV Form Deck
Table of Contents
LIGHTWEIGHT CONCRETE
Form Decks - Types 0.6FD, 0.6FDV
PROPERTIES
Thickness Cover Weight
Gage 3
4
˝ 143 ˝ 2 12˝
(in) (in) (psf)
9
28 0.0149 0.75 16˝
26 0.0179 0.90
35 35˝ Coverage ICC-ESApproved
ICC-ES APPROVED-
24 0.0238 1.19
REFERtoTOESR-3818
Refer ESR-3818
Roof Deck
22 0.0295 1.48
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
28 60 0.011 0.011 0.011 0.011 0.033 0.034 1190 1236 1534 583 910
26 60 0.013 0.013 0.013 0.013 0.042 0.044 1517 1576 1839 811 1278
24 60 0.018 0.018 0.018 0.018 0.060 0.060 2144 2144 2435 1352 2160
22 60 0.022 0.022 0.022 0.022 0.073 0.073 2631 2631 3006 1984 3201
CONSTRUCTION CLEAR SPANS
Composite Deck
24 3 - 7 4 - 3 4 - 4 1 - 1
Lightweight Concrete (110 psf)
28 2 - 0 2 - 5 2 - 5 0 - 7
26 2 - 5 2 - 11 2 - 11 0 - 9
5 43 0.394
24 3 - 2 3 - 9 3 - 10 1 - 0
22 3 - 5 4 - 5 4 - 3 1 - 2
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
LWC (γc = 110 pcf, f'c = 3000 psi, n = 14, Fys = 60000 psi)
#3 @ 9'' o.c. 0.147 400 400 400 400 400 400 400 400 400
4x4 - W4.0xW4.0 0.120 400 400 400 400 400 400 400 400 400
4 1/2 #3 @ 9'' o.c. 0.147 400 400 400 400 400 400 400 400 400
#4 @ 12'' o.c. 0.196 400 400 400 400 400 400 400 400 400
4x4 - W4.0xW4.0 0.120 400 400 400 400 400 400 400 400 400
5 #3 @ 9'' o.c. 0.147 400 400 400 400 400 400 400 400 400
#4 @ 12'' o.c. 0.196 400 400 400 400 400 400 400 400 400
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive
Code of Standard Practice
Discover the easiest way to specify Steel Roof and Floor Deck:
96 www.newmill.com/digital-tools
0.6FD, 0.6FDV Form Deck
Table of Contents
Form Decks - Types 0.6FD, 0.6FDV
NORMAL-WEIGHT CONCRETE
PROPERTIES
Thickness Cover Weight
Gage 3
4
˝ 143 ˝ 2 12˝
(in) (in) (psf)
9
28 0.0149 0.75 16˝
26 0.0179 0.90
35 35˝ Coverage ICC-ESApproved
ICC-ES APPROVED-
24 0.0238 1.19
REFERto
Refer TOESR-3818
ESR-3818
Roof Deck
22 0.0295 1.48
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
28 60 0.011 0.011 0.011 0.011 0.033 0.034 1190 1236 1534 583 910
26 60 0.013 0.013 0.013 0.013 0.042 0.044 1517 1576 1839 811 1278
24 60 0.018 0.018 0.018 0.018 0.060 0.060 2144 2144 2435 1352 2160
22 60 0.022 0.022 0.022 0.022 0.073 0.073 2631 2631 3006 1984 3201
CONSTRUCTION CLEAR SPANS
Composite Deck
Total Slab Concrete Maximum Construction Conc. Notes:
Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
28 2 - 2 2 - 7 2 - 8 0 - 7 2. Web crippling design strengths* and maximum construction
26 2 - 8 3 - 2 3 - 3 0 - 9 spans are based on 1 1/2'' for end bearing and 3'' for interior
2 1/2 27 0.185 bearing. Check web crippling if minimums are not met.
24 3 - 6 4 - 3 4 - 3 1 - 0
22 4 - 0 4 - 11 5 - 0 1 - 3 3. Maximum construction spans are based on ANSI/SDI
28 2 - 1 2 - 6 2 - 7 0 - 7 NC-2017 Standard for Non-Composite Steel Floor Deck
26 2 - 7 3 - 1 3 - 1 0 - 9 and the following construction loading:
3 33 0.227
Versa-Dek®
● Deck self-weight and concrete weight plus worst-case of
Normal-Weight Concrete (145 psf)
Long-Span Composite
24 3 - 5 4 - 0 4 - 1 1 - 0
22 3 - 9 4 - 9 4 - 8 1 - 3 either a 150 lb. concentrated load or a 20 psf
28 2 - 0 2 - 5 2 - 6 0 - 7 uniform load; or
26 2 - 6 3 - 0 3 - 0 0 - 9 ● Deck self-weight plus a 50 psf uniform
3 1/2 39 0.269
24 3 - 3 3 - 11 3 - 11 1 - 0 construction load, whichever controls.
22 3 - 7 4 - 6 4 - 5 1 - 3 4. Concrete weights do not include weight of deck.
Deep-Dek®
28 2 - 0 2 - 5 2 - 5 0 - 7 5. Deck profile has been accounted for in determining concrete
26 2 - 5 2 - 11 2 - 11 0 - 9 volumes. Deck and support deflections have not been
4 45 0.310
24 3 - 2 3 - 9 3 - 9 1 - 0 included in concrete volumes or weights.
22 3 - 5 4 - 4 4 - 3 1 - 2 6. Cantilever clear spans assume adjacent clear span is at least
28 1 - 11 2 - 4 2 - 4 0 - 7 3 times longer than the cantilever clear span and no greater
26 2 - 4 2 - 10 2 - 10 0 - 9 than spans shown. Bearing width at perimeter support
4 1/2 51 0.352
24 3 - 1 3 - 7 3 - 8 1 - 0 assumed to be 3'' minimum. Contact New Millennium
22 3 - 3 4 - 2 4 - 1 1 - 2 otherwise.
Form Deck
28 1 - 11 2 - 3 2 - 3 0 - 7
26 2 - 3 2 - 9 2 - 9 0 - 9
5 57 0.394
24 2 - 11 3 - 6 3 - 7 0 - 11
22 3 - 2 4 - 1 3 - 11 1 - 2
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
NWC (γc = 145 pcf, f'c = 3000 psi, n = 9, Fys = 60000 psi)
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 97
1.0FD, 1.0FDV Form Deck
Table of Contents
LIGHTWEIGHT CONCRETE
Form Decks - Types 1.0FD, 1.0FDV
PROPERTIES
Thickness Cover Weight 181 ˝ 4˝
Gage 2 87˝
(in) (in) (psf)
26 0.0179 0.94 1˝
24 0.0238 1.24
36 36˝ Coverage ICC-ES APPROVED
ICC-ES Approved -
22 0.0295 1.54
REFER TOESR-3818
Refer to ESR-3818
Roof Deck
20 0.0358 1.87
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
26 60 0.042 0.042 0.041 0.041 0.068 0.071 2428 2547 1663 466 828
24 60 0.056 0.056 0.056 0.056 0.098 0.105 3518 3782 2739 789 1422
22 60 0.070 0.070 0.070 0.070 0.129 0.132 4631 4744 3388 1169 2126
20 60 0.085 0.085 0.085 0.085 0.160 0.160 5749 5749 4101 1665 3047
CONSTRUCTION CLEAR SPANS
Composite Deck
22 6 - 3 7 - 10 7 - 9 2 - 2
Lightweight Concrete (110 psf)
26 3 - 7 4 - 2 4 - 3 1 - 2
24 4 - 8 5 - 6 5 - 7 1 - 8
5 41 0.375
22 5 - 2 6 - 8 6 - 5 2 - 0
20 5 - 6 7 - 5 6 - 10 2 - 4
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
LWC (γc = 110 pcf, f'c = 3000 psi, n = 14, Fys = 60000 psi)
4x4 - W4.0xW4.0 0.120 400 400 400 391 341 287 244 211 161
4x4 - W2.9xW2.9 0.087 400 400 400 359 296 249 212 183 140
4 1/2 4x4 - W4.0xW4.0 0.120 400 400 400 400 400 338 288 249 190
#3 @ 9'' o.c. 0.147 400 400 400 400 400 400 343 296 226
4x4 - W4.0xW4.0 0.120 400 400 400 400 400 390 332 287 219
5 #3 @ 9'' o.c. 0.147 400 400 400 400 400 400 397 342 262
#4 @ 12'' o.c. 0.196 400 400 400 400 400 400 400 400 339
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive
Code of Standard Practice
Discover the easiest way to specify Steel Roof and Floor Deck:
98 www.newmill.com/digital-tools
1.0FD, 1.0FDV Form Deck
Table of Contents
Form Decks - Types 1.0FD, 1.0FDV
NORMAL-WEIGHT CONCRETE
PROPERTIES
Thickness Cover Weight 4˝
Gage 181 ˝ 2 87˝
(in) (in) (psf)
26 0.0179 0.94 1˝
24 0.0238 1.24
36
36˝ Coverage ICC-ES Approved
ICC-ES APPROVED-
22 0.0295 1.54
0.0358 1.87
REFERto
Refer TOESR-3818
ESR-3818
Roof Deck
20
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
26 60 0.042 0.042 0.041 0.041 0.068 0.071 2428 2547 1663 466 828
24 60 0.056 0.056 0.056 0.056 0.098 0.105 3518 3782 2739 789 1422
22 60 0.070 0.070 0.070 0.070 0.129 0.132 4631 4744 3388 1169 2126
20 60 0.085 0.085 0.085 0.085 0.160 0.160 5749 5749 4101 1665 3047
CONSTRUCTION CLEAR SPANS
Composite Deck
Total Slab Concrete Maximum Construction Conc. Notes:
Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
26 4 - 0 4 - 9 4 - 10 1 - 3 2. Web crippling design strengths* and maximum construction
24 5 - 4 6 - 4 6 - 5 1 - 9 spans are based on 1 1/2'' for end bearing and 3'' for interior
2 1/2 24 0.167 bearing. Check web crippling if minimums are not met.
22 6 - 2 7 - 9 7 - 7 2 - 2
20 6 - 6 8 - 7 8 - 1 2 - 7 3. Maximum construction spans are based on ANSI/SDI
26 3 - 10 4 - 7 4 - 7 1 - 3 NC-2017 Standard for Non-Composite Steel Floor Deck
24 5 - 1 6 - 0 6 - 1 1 - 9 and the following construction loading:
3 30 0.209
Versa-Dek®
● Deck self-weight and concrete weight plus worst-case of
Normal-Weight Concrete (145 psf)
22 5 - 9 7 - 3 7 - 1 2 - 1
Long-Span Composite
20 6 - 1 8 - 2 7 - 6 2 - 6 either a 150 lb. concentrated load or a 20 psf
26 3 - 8 4 - 4 4 - 5 1 - 2 uniform load; or
24 4 - 10 5 - 8 5 - 9 1 - 8 ● Deck self-weight plus a 50 psf uniform
3 1/2 36 0.250
22 5 - 5 6 - 11 6 - 8 2 - 1 construction load, whichever controls.
20 5 - 9 7 - 9 7 - 1 2 - 5 4. Concrete weights do not include weight of deck.
Deep-Dek®
26 3 - 6 4 - 2 4 - 3 1 - 2 5. Deck profile has been accounted for in determining concrete
24 4 - 7 5 - 5 5 - 6 1 - 8 volumes. Deck and support deflections have not been
4 42 0.292
22 5 - 2 6 - 7 6 - 4 2 - 0 included in concrete volumes or weights.
20 5 - 6 7 - 4 6 - 9 2 - 4 6. Cantilever clear spans assume adjacent clear span is at least
26 3 - 5 4 - 0 4 - 1 1 - 2 3 times longer than the cantilever clear span and no greater
24 4 - 5 5 - 3 5 - 4 1 - 7 than spans shown. Bearing width at perimeter support
4 1/2 48 0.334
22 4 - 11 6 - 4 6 - 1 1 - 11 assumed to be 3'' minimum. Contact New Millennium
20 5 - 3 7 - 1 6 - 6 2 - 3 otherwise.
Form Deck
26 3 - 4 3 - 11 3 - 11 1 - 1
24 4 - 3 5 - 1 5 - 1 1 - 7
5 54 0.375
22 4 - 9 6 - 1 5 - 10 1 - 11
20 5 - 1 6 - 9 6 - 3 2 - 2
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
NWC (γc = 145 pcf, f'c = 3000 psi, n = 9, Fys = 60000 psi)
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 99
EHD-Dek
Table of Contents
LIGHTWEIGHT CONCRETE
Form Decks - Types EHD, EHDV
PROPERTIES 9
416 ˝ 3 3
Thickness Cover Weight 116 ˝ 116 ˝
Gage
(in) (in) (psf)
5
26 0.0179 0.98 116 ˝
24 0.0238 1.30
32 32˝ Coverage ICC-ES APPROVED
22 0.0295 1.61
0.0358 1.96
REFER TO ESR-1169
Roof Deck
20
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
26 60 0.073 0.073 0.072 0.072 0.095 0.104 3427 3724 1475 379 588
24 60 0.097 0.097 0.097 0.097 0.136 0.140 4874 5044 2607 650 1055
22 60 0.121 0.121 0.121 0.121 0.176 0.176 6305 6305 3621 971 1619
20 60 0.146 0.146 0.146 0.146 0.213 0.213 7650 7650 4385 1392 2367
CONSTRUCTION CLEAR SPANS
Composite Deck
#3 @ 9'' o.c. 0.147 400 400 400 361 308 266 231 203 161
4x4 - W4.0xW4.0 0.120 400 400 400 357 304 262 228 201 158
5 #3 @ 9'' o.c. 0.147 400 400 400 400 362 312 272 239 189
#4 @ 12'' o.c. 0.196 400 400 400 400 400 389 350 308 243
4x4 - W4.0xW4.0 0.120 400 400 400 400 348 300 261 230 181
5 1/2 #3 @ 9'' o.c. 0.147 400 400 400 400 400 358 312 274 217
#4 @ 12'' o.c. 0.196 400 400 400 400 400 400 400 355 281
Notes: 8. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive
Code of Standard Practice
Discover the easiest way to specify Steel Roof and Floor Deck:
100 www.newmill.com/digital-tools
EHD-Dek
Table of Contents
NORMAL-WEIGHT CONCRETE
Form Decks - Types EHD, EHDV
9
PROPERTIES 416 ˝ 3 3
116 ˝ 116 ˝
Thickness Cover Weight
Gage
(in) (in) (psf) 5
26 0.0179 0.98 116 ˝
24 0.0238 1.30 ICC-ES APPROVED
32 32˝ Coverage
22 0.0295 1.61
REFER TO ESR-1169
0.0358 1.96
Roof Deck
20
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
26 60 0.073 0.073 0.072 0.072 0.095 0.104 3427 3724 1475 379 588
24 60 0.097 0.097 0.097 0.097 0.136 0.140 4874 5044 2607 650 1055
22 60 0.121 0.121 0.121 0.121 0.176 0.176 6305 6305 3621 971 1619
20 60 0.146 0.146 0.146 0.146 0.213 0.213 7650 7650 4385 1392 2367
CONSTRUCTION CLEAR SPANS
Composite Deck
Total Slab Concrete Maximum Construction Conc. Notes:
Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
26 5 - 1 6 - 0 6 - 1 1 - 9 2. Web crippling design strengths* and maximum construction
24 6 - 6 7 - 9 7 - 10 2 - 3 spans are based on 1 1/2'' for end bearing and 3'' for interior
3 28 0.195 bearing. Check web crippling if minimums are not met.
22 7 - 0 9 - 0 8 - 8 2 - 9
20 7 - 6 9 - 10 9 - 3 3 - 2 3. Maximum construction spans are based on ANSI/SDI
26 4 - 10 5 - 8 5 - 9 1 - 8 NC-2017 Standard for Non-Composite Steel Floor Deck
24 6 - 2 7 - 3 7 - 4 2 - 2 and the following construction loading:
3 1/2 34 0.237
Versa-Dek®
● Deck self-weight and concrete weight plus worst-case of
Normal-Weight Concrete (145 psf)
22 6 - 7 8 - 8 8 - 2 2 - 7
Long-Span Composite
20 7 - 0 9 - 5 8 - 8 3 - 1 either a 150 lb. concentrated load or a 20 psf
26 4 - 7 5 - 5 5 - 6 1 - 7 uniform load; or
24 5 - 10 6 - 11 7 - 0 2 - 1 ● Deck self-weight plus a 50 psf uniform
4 40 0.278
22 6 - 3 8 - 2 7 - 9 2 - 6 construction load, whichever controls.
20 6 - 8 8 - 11 8 - 3 2 - 11 4. Concrete weights do not include weight of deck.
Deep-Dek®
26 4 - 5 5 - 3 5 - 3 1 - 7 5. Deck profile has been accounted for in determining concrete
24 5 - 7 6 - 8 6 - 8 2 - 1 volumes. Deck and support deflections have not been
4 1/2 46 0.320
22 6 - 0 7 - 10 7 - 5 2 - 6 included in concrete volumes or weights.
20 6 - 5 8 - 7 7 - 11 2 - 10 6. Cantilever clear spans assume adjacent clear span is at least
26 4 - 3 5 - 0 5 - 1 1 - 7 3 times longer than the cantilever clear span and no greater
24 5 - 4 6 - 4 6 - 5 2 - 0 than spans shown. Bearing width at perimeter support
5 52 0.362
22 5 - 9 7 - 6 7 - 1 2 - 5 assumed to be 3'' minimum. Contact New Millennium
20 6 - 2 8 - 3 7 - 7 2 - 9 otherwise.
Form Deck
26 4 - 2 4 - 10 4 - 11 1 - 6 7. Deck lengths over 40'-0'' require inquiry and special
24 5 - 2 6 - 2 6 - 2 2 - 0 accommodations. Please contact New Millennium for
5 1/2 58 0.403
22 5 - 7 7 - 2 6 - 11 2 - 4 further information.
20 5 - 11 7 - 11 7 - 4 2 - 7
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
NWC (γc = 145 pcf, f'c = 3000 psi, n = 9, Fys = 60000 psi)
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 101
1.5FD Form Deck
Table of Contents
LIGHTWEIGHT CONCRETE
Form Decks - Type 1.5FD
PROPERTIES
Thickness Cover Weight 6˝ 4 83 ˝
Gage 3 21 ˝
(in) (in) (psf)
22 0.0295 1.63 1 21 ˝
20 0.0358 1.98
36 ICC-ES
ICC-ESApproved
APPROVED-
18 0.0474 2.62 36˝ Coverage
REFERto
Refer TOESR-3818
ESR-3818
Roof Deck
16 0.0598 3.30
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.175 0.175 0.175 0.157 0.183 0.176 4391 4215 2009 654 1181
20 40 0.213 0.213 0.213 0.201 0.235 0.224 5624 5375 2428 932 1696
18 40 0.281 0.281 0.281 0.279 0.315 0.304 7553 7291 3192 1557 2858
16 40 0.355 0.355 0.355 0.355 0.395 0.390 9454 9332 3996 2381 4396
CONSTRUCTION CLEAR SPANS
Composite Deck
18 8 - 5 9 - 5 9 - 9 3 - 0
Lightweight Concrete (110 psf)
22 5 - 1 6 - 0 6 - 1 1 - 9
20 6 - 0 7 - 0 7 - 2 2 - 2
6 50 0.458
18 7 - 3 8 - 1 8 - 5 2 - 8
16 8 - 3 9 - 2 9 - 6 3 - 2
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
LWC (γc = 110 pcf, f'c = 3000 psi, n = 14, Fys = 60000 psi)
#4 @ 12'' o.c. 0.196 400 400 400 376 320 276 241 212 167
4x4 - W4.0xW4.0 0.120 400 400 400 357 305 263 229 201 159
5 1/2 #3 @ 9'' o.c. 0.147 400 400 400 400 353 305 265 233 184
#4 @ 12'' o.c. 0.196 400 400 400 400 386 332 290 255 201
4x4 - W4.0xW4.0 0.120 400 400 400 400 375 324 282 248 196
6 #4 @ 18'' o.c. 0.131 400 400 400 400 400 345 301 264 209
#3 @ 9'' o.c. 0.147 400 400 400 400 400 373 325 286 226
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive
Code of Standard Practice
Discover the easiest way to specify Steel Roof and Floor Deck:
102 www.newmill.com/digital-tools
1.5FD Form Deck
Table of Contents
Form Decks - Type 1.5FD NORMAL-WEIGHT CONCRETE
PROPERTIES 6˝
1 85 ˝ 2 21 ˝
Thickness Cover Weight 6˝ 4 83 ˝
Gage 3 21 ˝
(in) (in) (psf)
22 0.0295 1.63 1 21 ˝
20 0.0358 1.98
36 ICC-ESApproved
ICC-ES APPROVED-
18 0.0474 2.62 36˝
36˝ Coverage
Coverage REFERto
Refer TOESR-3818
ESR-3818
Roof Deck
16 0.0598 3.30
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.175 0.175 0.175 0.157 0.183 0.176 4391 4215 2009 654 1181
20 40 0.213 0.213 0.213 0.201 0.235 0.224 5624 5375 2428 932 1696
18 40 0.281 0.281 0.281 0.279 0.315 0.304 7553 7291 3192 1557 2858
16 40 0.355 0.355 0.355 0.355 0.395 0.390 9454 9332 3996 2381 4396
CONSTRUCTION CLEAR SPANS
Composite Deck
Total Slab Concrete Maximum Construction Conc. Notes:
Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
22 5 - 8 6 - 8 6 - 9 1 - 10 2. Web crippling design strengths* and maximum construction
20 6 - 8 7 - 10 7 - 11 2 - 3 spans are based on 1 1/2'' for end bearing and 3'' for interior
3 1/2 36 0.250 bearing. Check web crippling if minimums are not met.
18 8 - 1 9 - 1 9 - 4 2 - 11
16 9 - 2 10 - 2 10 - 7 3 - 6 3. Maximum construction spans are based on ANSI/SDI
22 5 - 5 6 - 4 6 - 5 1 - 10 NC-2017 Standard for Non-Composite Steel Floor Deck
20 6 - 5 7 - 5 7 - 7 2 - 2 and the following construction loading:
4 42 0.291
Versa-Dek®
● Deck self-weight and concrete weight plus worst-case of
Normal-Weight Concrete (145 psf)
Long-Span Composite
18 7 - 9 8 - 7 8 - 11 2 - 10
16 8 - 9 9 - 8 10 - 1 3 - 4 either a 150 lb. concentrated load or a 20 psf
22 5 - 2 6 - 1 6 - 2 1 - 9 uniform load; or
20 6 - 1 7 - 1 7 - 3 2 - 2 ● Deck self-weight plus a 50 psf uniform
4 1/2 48 0.333
18 7 - 5 8 - 3 8 - 6 2 - 9 construction load, whichever controls.
16 8 - 5 9 - 3 9 - 7 3 - 2 4. Concrete weights do not include weight of deck.
Deep-Dek®
22 5 - 0 5 - 10 5 - 11 1 - 9 5. Deck profile has been accounted for in determining concrete
20 5 - 11 6 - 10 6 - 11 2 - 1 volumes. Deck and support deflections have not been
5 54 0.375
18 7 - 1 7 - 11 8 - 2 2 - 8 included in concrete volumes or weights.
16 8 - 1 8 - 11 9 - 3 3 - 1 6. Cantilever clear spans assume adjacent clear span is at least
22 4 - 10 5 - 8 5 - 9 1 - 8 3 times longer than the cantilever clear span and no greater
20 5 - 8 6 - 7 6 - 8 2 - 1 than spans shown. Bearing width at perimeter support
5 1/2 60 0.416
18 6 - 10 7 - 7 7 - 11 2 - 7 assumed to be 3'' minimum. Contact New Millennium
16 7 - 10 8 - 7 8 - 11 2 - 11 otherwise.
Form Deck
22 4 - 8 5 - 6 5 - 6 1 - 8
20 5 - 6 6 - 4 6 - 6 2 - 0
6 66 0.458
18 6 - 7 7 - 4 7 - 7 2 - 6
16 7 - 7 8 - 3 8 - 7 2 - 10
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
NWC (γc = 145 pcf, f'c = 3000 psi, n = 9, Fys = 60000 psi)
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 103
1.5FDR, 1.5FDI, 1.5FDV, 1.5FDIV Form Deck
Table of Contents
PROPERTIES 6˝
1 85 ˝ 2 21 ˝
Thickness Cover Weight
Gage
(in) (in) (psf)
22 0.0295 1.63 1 21 ˝
20 0.0358 1.98
36 ICC-ESApproved
ICC-ES APPROVED-
18 0.0474 2.62 36˝ Coverage
0.0598 3.30 REFERto
Refer TOESR-3818
ESR-3818
Roof Deck
16
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.163 0.175 0.157 0.175 0.176 0.183 4215 4391 2009 654 1181
20 40 0.205 0.213 0.201 0.213 0.224 0.235 5375 5624 2428 932 1696
18 40 0.280 0.281 0.279 0.281 0.304 0.315 7291 7553 3192 1557 2858
16 40 0.355 0.355 0.355 0.355 0.390 0.395 9332 9454 3996 2381 4396
CONSTRUCTION CLEAR SPANS
Composite Deck
22 5 - 1 6 - 0 6 - 1 1 - 10
20 6 - 0 7 - 0 7 - 1 2 - 3
6 46 0.422
18 7 - 4 8 - 6 8 - 8 2 - 10
16 8 - 6 9 - 6 9 - 10 3 - 3
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
LWC (γc = 110 pcf, f'c = 3000 psi, n = 14, Fys = 60000 psi)
#4 @ 12'' o.c. 0.196 400 353 321 294 271 252 197 156 126
4x4 - W4.0xW4.0 0.120 400 400 369 311 265 229 175 138 112
5 1/2 #3 @ 9'' o.c. 0.147 400 400 388 356 310 267 205 162 131
#4 @ 12'' o.c. 0.196 400 400 380 349 322 299 235 185 150
4x4 - W4.0xW4.0 0.120 400 400 400 385 328 283 216 171 138
6 #4 @ 18'' o.c. 0.131 400 400 400 400 353 304 233 184 149
#3 @ 9'' o.c. 0.147 400 400 400 400 381 329 252 199 161
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive
Code of Standard Practice
Discover the easiest way to specify Steel Roof and Floor Deck:
104 www.newmill.com/digital-tools
1.5FDR, 1.5FDI, 1.5FDV, 1.5FDIV Form Deck
Table of Contents
Form Decks - Types 1.5FDR, 1.5FDI, 1.5FDV, 1.5FDIV
NORMAL-WEIGHT CONCRETE
PROPERTIES 6˝
1 85 ˝ 2 21 ˝
Thickness Cover Weight
Gage
(in) (in) (psf)
22 0.0295 1.63 1 21 ˝
20 0.0358 1.98
36 ICC-ES Approved
ICC-ES APPROVED -
18 0.0474 2.62 36˝ Coverage
REFERto
Refer TOESR-3818
ESR-3818
Roof Deck
16 0.0598 3.30
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.163 0.175 0.157 0.175 0.176 0.183 4215 4391 2009 654 1181
20 40 0.205 0.213 0.201 0.213 0.224 0.235 5375 5624 2428 932 1696
18 40 0.280 0.281 0.279 0.281 0.304 0.315 7291 7553 3192 1557 2858
16 40 0.355 0.355 0.355 0.355 0.390 0.395 9332 9454 3996 2381 4396
CONSTRUCTION CLEAR SPANS
Composite Deck
Total Slab Concrete Maximum Construction Conc. Notes:
Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
22 5 - 9 6 - 9 6 - 10 2 - 0 2. Web crippling design strengths* and maximum construction
20 6 - 9 8 - 0 8 - 1 2 - 5 spans are based on 1 1/2'' for end bearing and 3'' for interior
3 1/2 31 0.213 bearing. Check web crippling if minimums are not met.
18 8 - 4 9 - 8 9 - 11 3 - 1
16 9 - 8 10 - 9 11 - 1 3 - 8 3. Maximum construction spans are based on ANSI/SDI
22 5 - 5 6 - 5 6 - 6 1 - 11 NC-2017 Standard for Non-Composite Steel Floor Deck
20 6 - 5 7 - 7 7 - 8 2 - 4 and the following construction loading:
4 37 0.255
Versa-Dek®
● Deck self-weight and concrete weight plus worst-case of
Normal-Weight Concrete (145 psf)
Long-Span Composite
18 7 - 11 9 - 2 9 - 4 3 - 0
16 9 - 1 10 - 2 10 - 6 3 - 6 either a 150 lb. concentrated load or a 20 psf
22 5 - 3 6 - 2 6 - 3 1 - 10 uniform load; or
20 6 - 2 7 - 3 7 - 4 2 - 3 ● Deck self-weight plus a 50 psf uniform
4 1/2 43 0.297
18 7 - 6 8 - 9 8 - 10 2 - 10 construction load, whichever controls.
16 8 - 8 9 - 8 10 - 1 3 - 4 4. Concrete weights do not include weight of deck.
Deep-Dek®
22 5 - 0 5 - 11 5 - 11 1 - 10 5. Deck profile has been accounted for in determining concrete
20 5 - 11 6 - 11 7 - 0 2 - 3 volumes. Deck and support deflections have not been
5 49 0.338
18 7 - 2 8 - 4 8 - 6 2 - 9 included in concrete volumes or weights.
16 8 - 4 9 - 3 9 - 7 3 - 2 6. Cantilever clear spans assume adjacent clear span is at least
22 4 - 10 5 - 8 5 - 9 1 - 9 3 times longer than the cantilever clear span and no greater
20 5 - 8 6 - 8 6 - 9 2 - 2 than spans shown. Bearing width at perimeter support
5 1/2 55 0.380
18 6 - 11 8 - 0 8 - 2 2 - 8 assumed to be 3'' minimum. Contact New Millennium
16 8 - 0 8 - 11 9 - 3 3 - 1 otherwise.
Form Deck
22 4 - 8 5 - 6 5 - 7 1 - 9
20 5 - 6 6 - 5 6 - 6 2 - 1
6 61 0.422
18 6 - 8 7 - 9 7 - 10 2 - 7
16 7 - 9 8 - 7 8 - 11 2 - 11
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
NWC (γc = 145 pcf, f'c = 3000 psi, n = 9, Fys = 60000 psi)
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 105
2.0FD Form Deck
Table of Contents
LIGHTWEIGHT CONCRETE
Form Decks - Type 2.0FD
PROPERTIES Optional run-out side lap for screws
Thickness Cover Weight 7˝
Gage 12˝
(in) (in) (psf) 5˝
22 0.0295 1.57 2˝
20 0.0358 1.90
36 ICC-ES APPROVED
18 0.0474 2.52 36˝ Coverage REFER TO ESR-3818
Roof Deck
16 0.0598 3.17
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.341 0.341 0.337 0.328 0.257 0.261 6153 6263 1474 321 617
20 40 0.419 0.419 0.418 0.410 0.342 0.346 8189 8285 1963 459 882
18 40 0.555 0.555 0.554 0.554 0.506 0.510 12108 12205 2590 769 1477
16 40 0.701 0.701 0.699 0.700 0.650 0.651 15572 15583 3255 1176 2260
CONSTRUCTION CLEAR SPANS
Composite Deck
4 1/2 32 0.289
Long-Span Composite
16 11 - 10 13 - 8 13 - 10 4 - 7 uniform load; or
22 7 - 2 8 - 4 8 - 6 2 - 7 ● Deck self-weight plus a 50 psf uniform
20 8 - 7 9 - 8 10 - 0 3 - 3 construction load, whichever controls.
5 36 0.331
18 10 - 9 11 - 8 12 - 1 4 - 0 4. Concrete weights do not include weight of deck.
Versa-Dek®
16 10 - 9 12 - 3 12 - 8 4 - 2
22 6 - 5 6 - 10 7 - 7 2 - 5
20 7 - 9 8 - 8 8 - 11 2 - 11
6 1/2 50 0.456
18 9 - 8 10 - 6 10 - 10 3 - 7
16 10 - 5 11 - 10 12 - 3 4 - 1
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
LWC (γc = 110 pcf, f'c = 3000 psi, n = 14, Fys = 60000 psi)
(in /ft)
(in) Deformed Bars) 6 - 0 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0
6x6 - W4.0xW4.0 0.080 120 88 77 68 60 53 43 36 30
4 4x4 - W2.9xW2.9 0.087 131 97 84 74 66 58 47 39 33
4x4 - W4.0xW4.0 0.120 174 128 111 98 87 77 63 43 36
6x6 - W4.0xW4.0 0.080 155 114 99 87 77 69 56 46 39
4 1/2 4x4 - W2.9xW2.9 0.087 169 124 108 95 84 75 61 50 42
4x4 - W4.0xW4.0 0.120 228 167 146 128 114 101 82 59 50
4x4 - W2.9xW2.9 0.087 206 152 132 116 103 92 74 61 52
5 4x4 - W4.0xW4.0 0.120 279 205 179 157 139 124 101 77 65
#3 @ 9'' o.c. 0.147 330 242 211 186 164 147 119 88 74
4x4 - W4.0xW4.0 0.120 331 243 212 186 165 147 119 97 82
5 1/2 #3 @ 9'' o.c. 0.147 393 289 252 221 196 175 142 111 93
General Information
#4 @ 12'' o.c. 0.196 400 351 305 268 238 212 172 118 99
4x4 - W4.0xW4.0 0.120 383 281 245 215 191 170 138 114 96
6 #4 @ 18'' o.c. 0.131 400 294 256 225 200 178 144 119 100
#3 @ 9'' o.c. 0.147 400 335 292 257 228 203 164 136 114
4x4 - W4.0xW4.0 0.120 400 319 278 244 216 193 156 129 109
6 1/2 #4 @ 18'' o.c. 0.131 400 336 292 257 228 203 164 136 114
#3 @ 9'' o.c. 0.147 400 382 333 292 259 231 187 155 130
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive steel
Code of Standard Practice
Discover the easiest way to specify Steel Roof and Floor Deck:
106 www.newmill.com/digital-tools
2.0FD Form Deck
Table of Contents
Form Decks - Type 2.0FD NORMAL-WEIGHT CONCRETE
Roof Deck
16 0.0598 3.17
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.341 0.341 0.337 0.328 0.257 0.261 6153 6263 1474 321 617
20 40 0.419 0.419 0.418 0.410 0.342 0.346 8189 8285 1963 459 882
18 40 0.555 0.555 0.554 0.554 0.506 0.510 12108 12205 2590 769 1477
16 40 0.701 0.701 0.699 0.700 0.650 0.651 15572 15583 3255 1176 2260
CONSTRUCTION CLEAR SPANS
Composite Deck
Total Slab Concrete Maximum Construction Conc. Notes:
Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
2. Web crippling design strengths* and maximum construction
22 7 - 2 8 - 5 8 - 6 2 - 7
spans are based on 2'' for end bearing and 4'' for interior
20 8 - 8 9 - 8 10 - 0 3 - 3
4 36 0.248 bearing. Check web crippling if minimums are not met.
18 10 - 9 11 - 9 12 - 2 4 - 0 3. Maximum construction spans are based on ANSI/SDI
16 11 - 6 13 - 2 13 - 6 4 - 6 NC-2017 Standard for Non-Composite Steel Floor Deck
22 6 - 10 7 - 9 8 - 1 2 - 6 and the following construction loading:
20 8 - 3 9 - 3 9 - 7 3 - 1 ● Deck self-weight and concrete weight plus worst-case of
Versa-Dek®
4 1/2 42 0.289
Long-Span Composite
18 10 - 3 11 - 2 11 - 7 3 - 10
Normal Weight Concrete (145 pcf)
Deep-Dek®
16 10 - 7 12 - 0 12 - 5 4 - 1
22 6 - 1 6 - 6 7 - 4 2 - 4 volumes. Deck and support deflections have not been
20 7 - 6 8 - 5 8 - 9 2 - 11 included in concrete volumes or weights.
5 1/2 54 0.373 6. Cantilever clear spans assume adjacent clear span is at least
18 9 - 6 10 - 3 10 - 7 3 - 6
3 times longer than the cantilever clear span and no greater
16 10 - 2 11 - 6 11 - 11 3 - 11
than spans shown. Bearing width at perimeter support
22 5 - 6 6 - 0 6 - 10 2 - 3
assumed to be 4'' minimum. Contact New Millennium otherwise.
20 7 - 3 8 - 1 8 - 5 2 - 9
6 60 0.414
18 9 - 2 9 - 10 10 - 2 3 - 4
16 9 - 10 11 - 1 11 - 6 3 - 10
Form Deck
22 5 - 0 5 - 6 6 - 3 2 - 1
20 7 - 0 7 - 10 8 - 1 2 - 8
6 1/2 66 0.456
18 8 - 10 9 - 6 9 - 10 3 - 3
16 9 - 7 10 - 8 11 - 1 3 - 8
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
NWC (γc = 145 pcf, f'c = 3000 psi, n = 9, Fys = 60000 psi)
#4 @ 12'' o.c. 0.196 400 351 305 268 238 212 172 118 99
4x4 - W4.0xW4.0 0.120 383 281 245 215 191 170 138 114 96
6 #4 @ 18'' o.c. 0.131 400 294 256 225 200 178 144 119 100
#3 @ 9'' o.c. 0.147 400 335 292 257 228 203 164 136 114
4x4 - W4.0xW4.0 0.120 400 319 278 244 216 193 156 129 109
6 1/2 #4 @ 18'' o.c. 0.131 400 336 292 257 228 203 164 136 114
#3 @ 9'' o.c. 0.147 400 382 333 292 259 231 187 155 130
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive steel
Code of Standard Practice
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 107
3.0FD Form Deck
Table of Contents
LIGHTWEIGHT CONCRETE
Form Decks - Type 3.0FD
PROPERTIES Optional run-out side lap for screws
Thickness Cover Weight 7 41 ˝ 12˝
Gage
(in) (in) (psf)
4 43 ˝
22 0.0295 1.71 3˝
20 0.0358 2.07
36 ICC-ES APPROVED
18 0.0474 2.74
36˝ Coverage REFER TO ESR-3818
Roof Deck
16 0.0598 3.45
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.770 0.770 0.764 0.750 0.407 0.424 9749 10151 1416 336 677
20 40 0.946 0.946 0.945 0.934 0.537 0.556 12871 13319 2227 482 967
18 40 1.253 1.253 1.252 1.253 0.794 0.802 19016 19213 3895 811 1615
16 40 1.580 1.580 1.579 1.579 1.012 1.013 24245 24264 4901 1245 2466
CONSTRUCTION CLEAR SPANS
Composite Deck
16 14 - 0 16 - 4 16 - 5 5 - 5 uniform load; or
22 8 - 7 8 - 7 9 - 9 3 - 3 ● Deck self-weight plus a 50 psf uniform
20 11 - 0 11 - 9 12 - 2 4 - 0 construction load, whichever controls.
6 41 0.375
18 12 - 11 14 - 1 14 - 7 4 - 10 4. Concrete weights do not include weight of deck.
Versa-Dek®
16 13 - 0 14 - 9 15 - 3 5 - 1
22 6 - 6 7 - 0 8 - 0 2 - 8
20 9 - 10 10 - 0 11 - 0 3 - 8
7 1/2 55 0.500
18 12 - 1 12 - 9 13 - 2 4 - 4
16 12 - 9 14 - 4 14 - 10 4 - 11
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
LWC (γc = 110 pcf, f'c = 3000 psi, n = 14, Fys = 60000 psi)
2
(in /ft)
(in) Deformed Bars) 7 - 0 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0
6x6 - W4.0xW4.0 0.080 91 70 55 45 37 31 26 23 20
5 4x4 - W2.9xW2.9 0.087 100 76 60 49 40 34 29 25 22
4x4 - W4.0xW4.0 0.120 134 103 81 66 54 46 39 34 29
4x4 - W2.9xW2.9 0.087 127 98 77 62 52 43 37 32 28
5 1/2 4x4 - W4.0xW4.0 0.120 172 132 104 84 70 59 50 43 37
#3 @ 9'' o.c. 0.147 202 154 122 99 82 69 58 50 44
4x4 - W4.0xW4.0 0.120 210 161 127 103 85 71 61 52 46
6 #4 @ 18'' o.c. 0.131 217 166 131 106 88 74 63 54 47
#3 @ 9'' o.c. 0.147 248 190 150 122 100 84 72 62 54
4x4 - W4.0xW4.0 0.120 248 190 150 121 100 84 72 62 54
6 1/2 #4 @ 18'' o.c. 0.131 258 198 156 126 104 88 75 64 56
General Information
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive steel
rests on deck and negative steel cover = 3/4''.
● Galvanized deck. If non-galvanized deck or temporary shoring is used, the weight of the slab must be deducted from the uniform loads.
● End span of three span condion and ACI moment coefficients.
● Slab deflecon is limited to a minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
108 www.newmill.com/digital-tools
3.0FD Form Deck
Table of Contents
NORMAL-WEIGHT CONCRETE
Form Decks - Type 3.0FD
PROPERTIES Optional run-out side lap for screws
Thickness Cover Weight 7 41 ˝ 12˝
Gage
(in) (in) (psf)
4 43 ˝
22 0.0295 1.71 3˝
20 0.0358 2.07
36 ICC-ES APPROVED
18 0.0474 2.74
36˝ Coverage REFER TO ESR-3818
Roof Deck
16 0.0598 3.45
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.770 0.770 0.764 0.750 0.407 0.424 9749 10151 1416 336 677
20 40 0.946 0.946 0.945 0.934 0.537 0.556 12871 13319 2227 482 967
18 40 1.253 1.253 1.252 1.253 0.794 0.802 19016 19213 3895 811 1615
16 40 1.580 1.580 1.579 1.579 1.012 1.013 24245 24264 4901 1245 2466
CONSTRUCTION CLEAR SPANS
Composite Deck
Total Slab Concrete Maximum Construction Conc. Notes:
Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
2. Web crippling design strengths* and maximum construction
22 8 - 5 8 - 5 9 - 7 3 - 2
spans are based on 2 1/2'' for end bearing and 5'' for interior
20 10 - 11 11 - 7 12 - 0 4 - 0
5 42 0.292 bearing. Check web crippling if minimums are not met.
18 12 - 10 14 - 0 14 - 6 4 - 10 3. Maximum construction spans are based on ANSI/SDI
16 13 - 6 15 - 8 15 - 10 5 - 3 NC-2017 Standard for Non-Composite Steel Floor Deck
22 7 - 5 7 - 8 8 - 9 2 - 11 and the following construction loading:
20 10 - 4 10 - 11 11 - 6 3 - 10 ● Deck self-weight and concrete weight plus worst-case of
Versa-Dek®
5 1/2 48 0.333
Long-Span Composite
18 12 - 5 13 - 4 13 - 10 4 - 7
Normal Weight Concrete (145 pcf)
Deep-Dek®
16 12 - 9 14 - 4 14 - 10 4 - 11 5. Deck profile has been accounted for in determining concrete
22 5 - 11 6 - 7 7 - 5 2 - 5 volumes. Deck and support deflections have not been
20 9 - 6 9 - 4 10 - 7 3 - 6 included in concrete volumes or weights.
6 1/2 60 0.417 6. Cantilever clear spans assume adjacent clear span is at least
18 11 - 9 12 - 4 12 - 9 4 - 3
3 times longer than the cantilever clear span and no greater
16 12 - 5 13 - 10 14 - 4 4 - 9
than spans shown. Bearing width at perimeter support
22 5 - 5 6 - 1 6 - 9 2 - 3
assumed to be 5'' minimum. Contact New Millennium otherwise.
20 9 - 2 8 - 8 9 - 11 3 - 3
7 66 0.458
18 11 - 6 11 - 11 12 - 4 4 - 1
Form Deck
16 12 - 2 13 - 4 13 - 10 4 - 7
22 5 - 0 5 - 8 6 - 3 2 - 1
20 8 - 10 8 - 2 9 - 3 3 - 1
7 1/2 72 0.500
18 11 - 1 11 - 6 11 - 11 3 - 11
16 11 - 11 12 - 11 13 - 5 4 - 5
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
NWC (γc = 145 pcf, f'c = 3000 psi, n = 9, Fys = 60000 psi)
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive steel
rests on deck and negative steel cover = 3/4''.
● Galvanized deck. If non-galvanized deck or temporary shoring is used, the weight of the slab must be deducted from the uniform loads.
● End span of three span condion and ACI moment coefficients.
● Slab deflecon is limited to a minimum of Clear Span/360 or 1'' under service level superimposed loading.
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 109
Typical Fastener Layouts
Table of Contents
Deck attachment patterns are designed by the engineer of record. The type of fastening
system used will depend on the uplift capacity, diaphragm shear capacity and the
thickness of the supporting members. The different types of systems that can be used
are power driven fasteners, arc spot welds, arc seam welds and self-drilling screws.
Roof Deck
Composite Deck
Deep-Dek®
Long-Span Composite
Versa-Dek®
Form Deck
Typical Fastener Layouts
General Information
Code of Standard Practice
Discover the easiest way to specify Steel Roof and Floor Deck:
110 www.newmill.com/digital-tools
Long-Span Composite
Table of Contents Roof Deck Composite Deck Form Deck Typical Fastener Layouts General Information Code of Standard Practice
Versa-Dek® Deep-Dek®
111
Typical Fastener Layouts
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools
Long-Span Composite
Code of Standard Practice General Information Typical Fastener Layouts Form Deck Composite Deck Roof Deck Table of Contents
Versa-Dek® Deep-Dek®
General
Information
Table of Contents
To ensure our customers realize a better steel experience, New Millennium
is committed to providing the best, most up-to-date information related
to steel roof and floor deck. Click on the links below to learn more.
Roof Deck
Floor Deck Design.................................................................................................... 114
Composite Deck
Web Crippling Support Reactions......................................................................115
Versa-Dek®
Long-Span Composite
Standard Accessory Details................................................................................. 117
Deep-Dek®
Floor Deck Accessory Details............................................................................... 118
Form Deck
Bill of Materials............................................................................................. 120 – 121
newmill.com 113
Floor Deck Design
Table of Contents
commentary. These
These diagrams should be used only for the design of the deck as a form. The concrete slab shall be designed in
accordance the ACI 318.
Discover the easiest way to specify Steel Roof and Floor Deck:
114 www.newmill.com/digital-tools
Composite and Form Deck WebCrippling
Web Crippling Support
SupportReactions
Reactions
Table of Contents
P = 150 lbs. concentrated Live Load
W1 = Slab weight + deck weight (psf)
W2 = 20 psf uniform constr. Live Load
L = Clear span length (ft)
Note: Live Loads P and W2 listed are
Roof Deck
minimums, increase when actual
construction loads dictate.
Composite Deck
ALLOWABLE REACTIONS AT EXTERIOR & INTERIOR SUPPORTS - ASD
Allowable Exterior (Rext) / Interior (Rint) Reaction (lbs/ft of width)
Fy
Type4 Gage3 Bearing Length (in)
(ksi)
1 1/2 2 2 1/2 3 3 1/2 4 4 1/2 5 5 1/2 6
28 583 / 838 640 / 910 640 / 910 640 / 910 640 / 910 640 / 910 640 / 910 640 / 910 640 / 910 640 / 910
0.6FD 26 811 / 1182 887 / 1278 887 / 1278 887 / 1278 887 / 1278 887 / 1278 887 / 1278 887 / 1278 887 / 1278 887 / 1278
60
0.6FDV 24 1352 / 2008 1470 / 2160 1470 / 2160 1470 / 2160 1470 / 2160 1470 / 2160 1470 / 2160 1470 / 2160 1470 / 2160 1470 / 2160
Versa-Dek®
Long-Span Composite
22 1984 / 2989 2149 / 3201 2149 / 3201 2149 / 3201 2149 / 3201 2149 / 3201 2149 / 3201 2149 / 3201 2149 / 3201 2149 / 3201
26 466 / 662 517 / 724 561 / 779 601 / 828 632 / 867 632 / 867 632 / 867 632 / 867 632 / 867 632 / 867
1.0FD 24 789 / 1149 870 / 1251 941 / 1341 1006 / 1422 1055 / 1483 1055 / 1483 1055 / 1483 1055 / 1483 1055 / 1483 1055 / 1483
60
1.0FDV 22 1169 / 1733 1285 / 1879 1387 / 2009 1479 / 2126 1548 / 2213 1548 / 2213 1548 / 2213 1548 / 2213 1548 / 2213 1548 / 2213
Deep-Dek®
20 1665 / 2504 1824 / 2707 1964 / 2886 2091 / 3047 2183 / 3165 2183 / 3165 2183 / 3165 2183 / 3165 2183 / 3165 2183 / 3165
1.5FD 22 654 / 962 719 / 1044 776 / 1116 827 / 1181 875 / 1240 881 / 1248 881 / 1248 881 / 1248 881 / 1248 881 / 1248
1.5FDR1 20 932 / 1393 1021 / 1506 1100 / 1606 1171 / 1696 1236 / 1779 1243 / 1787 1243 / 1787 1243 / 1787 1243 / 1787 1243 / 1787
40
1.5CD2 18 1557 / 2377 1698 / 2557 1822 / 2715 1934 / 2858 2037 / 2990 2043 / 2998 2043 / 2998 2043 / 2998 2043 / 2998 2043 / 2998
1.5CDR
16 2381 / 3693 2586 / 3955 2766 / 4187 2929 / 4396 3079 / 4589 3080 / 4590 3080 / 4590 3080 / 4590 3080 / 4590 3080 / 4590
Form Deck
22 292 / 458 321 / 497 347 / 531 370 / 562 391 / 590 411 / 617 429 / 641 447 / 665 463 / 687 479 / 709
2.0FD 20 419 / 662 459 / 716 494 / 763 526 / 806 556 / 845 583 / 882 608 / 916 633 / 949 656 / 979 678 / 1009
40
2.0CD 18 705 / 1128 769 / 1213 825 / 1288 876 / 1356 922 / 1419 966 / 1477 1007 / 1531 1045 / 1583 1082 / 1632 1117 / 1679
16 1083 / 1750 1176 / 1875 1258 / 1985 1333 / 2084 1401 / 2175 1464 / 2260 1524 / 2340 1580 / 2415 1634 / 2487 1685 / 2555
22 283 / 466 311 / 506 336 / 541 358 / 572 379 / 601 398 / 628 416 / 653 433 / 677 449 / 700 465 / 722
3.0FD 20 409 / 675 448 / 730 482 / 778 514 / 821 542 / 862 569 / 899 594 / 934 618 / 967 640 / 998 662 / 1029
40
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 115
Fire Resistance Ratings
Table of Contents
New Millennium deck products are approved for use in UL fire rated assemblies. Please visit UL/ULC Online Certifications
Directory, UL/ULC File Numbers R20577 and R22282 (links provided below) for an up-to-date listing of UL/ULC Designs in which
New Millennium deck products have been approved. UL design numbering system has been provided below for your use in
navigating to the specific construction types required for your project.
Floors - Ceilings
Refer to UL report CHWX.R20577
CHWX.R20577 for New Millennium deck types.
Floors - Ceilings
Refer to UL report CJFS.R22282
CJFS.R22282 for New Millennium deck types.
D900-999: Concrete on steel deck (as structural framing member) w/no protection
L500-599: Wood on steel deck (as structural framing member) w/gypsum board
Floors - Ceilings (Canada)
Refer to ULC report CHWXC.R20577
CHWXC.R20577 for New Millennium deck types.
General Information
Discover the easiest way to specify Steel Roof and Floor Deck:
116 www.newmill.com/digital-tools
Standard
Standard Accessories
Accessories
Standard & Roof
& Roof
Accessories Accessory
Accessory
& Roof Details
Details
Accessory Details
Table of Contents
STANDARDDECK
STANDARD DECKACCESSORIES
ACCESSORIES A (7") 3378"
STANDARDDECK
STANDARD DECKACCESSORIES
ACCESSORIES B A (7") 3378"
28"
Notes: B Std. Dims: 28"
Notes:
1. Accessories are furnished with G60 galvanized C (12") Std. Dims:
FS1: B = 112"
1. Accessories are furnished 1
coating minimum, in 10'-0"with G60 galvanized
lengths. C (2") FS2: B = 13"12"
FS1:
2. coating
Standardminimum, in 10'-0"
accessories are 20lengths.
gage - U.N.O. FS2: B = 3"
2. Standard
3. New accessories
Millennium are 20 gage
can provide - U.N.O.
special light-gage
3. New Millennium
accessories canyour
to meet provide special
project light-gage
requirements, FILLER SHEET - B & N (FSx)
Roof Deck
accessories to meet
including notched oryour projectPour
reinforced requirements,
Stops and FILLER SHEET - B & N (FSx)
including notched
accessories or 304
made of reinforced Pour
stainless Stops
steel. and
Contact
Std. Dims:
" 78"
24"24"
accessories
New madefor
Millennium of availability
304 stainlessandsteel. Contact
pricing. A
B (112")
1
297829
New Millennium for availability and pricing. Std.
GF3:Dims:
A = 4" (3" Gap) A
GF3:
GF6: A = 4"
7",(3"
14 Gap)
Ga. (6" Gap) B 2")
(1
C (153°) GF6:
GF9: A = 7",
10",1414Ga.
Ga.(6"
(9"Gap)
Gap) 14 Ga.
Std. Dims: C (153°) GF9:
GF12:AA= =10",
13",1412Ga.
Ga.(9" Gap)
(12" Gap) 14 Ga.
Std. Dims:
RVP1: A & B = 412" A B GF12:
ContactA =New
13",Millennium
12 Ga. (12"for
Gap)
gage reqmts.
RVP2: A & B = 46"12"
RVP1: A B Contact New
when total NWMillennium for gage
concrete slab reqmts.
exceeds 12"
Composite Deck
RVP2: A & B = 6" when total NW concrete slab exceeds 12"
RIDGE/VALLEY PLATE (RVPx) GIRDER FILLER (GFx)
RIDGE/VALLEY PLATE (RVPx) GIRDER FILLER (GFx)
121"121"
A (1") A (112") RECESSED SUMP PAN (SUMP)
A (1") A (112")Std. Dims: RECESSED SUMP PAN (SUMP)
Std. Dims: Std. Dims:
A Std. Dims:
FP6: A = 6" B B
Std.
ZC1:Dims:
B = 112" Std.
ZEE1:Dims:
B = 2"
A FP9: A = 6"
FP6: 9" B B MISC. STOCK ITEMS
ZC2: B = 12"12"
ZC1: ZEE1:
ZEE2: B = 2"
312"
FP12:AA= =9"12", 18 Ga.
FP9: C (1") ZC3: B = 2"
ZC2: 3" C (Specify)
ZEE2: B = 312" MISC. STOCK #10-16
10-1/10-1FM: ITEMS x 3" Type 1 Side Lap Screw
C (1") C (Specify) 4
FP12: A = 12", 18 Ga.
Versa-Dek®
3
Long-Span Composite
ZC3: B = 3" 10-3/10-3FM: #10-16 xX 443"" Type
10-1/10-1FM: Type 13 Side
Side Lap
Lap Screw
Screw
FLAT PLATE (FPx) Z CLOSURE (ZCx) ZEE CLOSURE - VERSA (ZEEx) 10-3/10-3FM: 3
#12-14 X 443" Type 3 Side Lap Screw
12-3/12-3FM: #10-16
FLAT PLATE (FPx) Z CLOSURE (ZCx) ZEE CLOSURE - VERSA (ZEEx) 12-3/12-3FM: 3
#12-24 X 41"14"Type
12-5/12-5FM: #12-14 Type3 5Side Lap Screw
Support Screw
12-5/12-5FM:
COL: 12" x 24"#12-24 X 114Plate
x 20 Gage " TypeColumn
5 Support Screw
Closure
Std. Dims: COL:
or 27"12" x 24"
x 96" x 20Lath-Type
Metal Gage PlateColumn
ColumnClosure*
Closure
Deep-Dek®
B (1") Std. Dims:
PS1: A = 3" or
WW:27"Weld
x 96"Washer
Metal Lath-Type Column
w/ 83" Ø Hole, Closure*
16 Ga.
C C
Std. Dims:
1 ") 1 ")
(2 (2
Form Deck
** Not supplied by New Millennium
ROOF DECK
ROOF DECKACCESSORY
ACCESSORYINSTALLATION
INSTALLATION DETAILS
DETAILS
ROOF DECK
ROOF DECKACCESSORY
ACCESSORYINSTALLATION
INSTALLATION DETAILS
DETAILS
Note:
Note:
1. Accessories shall be attached to supporting structure or deck as required
1. Accessories shall be
for serviceability, butattached to supporting
spaced not structure
to exceed criteria or deck
shown as required
in details.
for serviceability, but spaced not to exceed criteria shown in details.
Filler Sheet
Filler
Mk: FSxSheet
Mk: FSx
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 117
Floor Deck Accessory Details
Floor Deck Accessory Details
Table of Contents
FLOOR
FLOORDECK
DECKACCESSORY
ACCESSORYINSTALLATION DETAILS
INSTALLATION DETAILS
Note:
1. Accessories shall be attached to supporting structure or deck as required
for serviceability, but spaced not to exceed criteria shown in details.
Pour Stop 1" long welds Fasten @ 24" o.c. Cell Closure
Mk: PSx @ 12" o.c. Mk: CCx
Roof Deck
Side Closure Weld @ 24" o.c. Fasten as required Cell Closure Mk: CCx
Mk: SCx (24" o.c. max.) Field cut at down ribs if interference
with shear stud installation occurs
Deep-Dek®
Long-Span Composite
Field Cut
Versa-Dek®
Weld @ 24" o.c. Girder Filler Weld @ 24" o.c. Fasten to support "Z" Closure
Mk: GFx & deck @ 24" o.c. Mk: ZCx
Form Deck
Gap
Typical Fastener Layouts
Discover the easiest way to specify Steel Roof and Floor Deck:
118 www.newmill.com/digital-tools
Pour Stop GagePour
Selection
Stop Gage Selection
Table of Contents
GAGE SELECTION TABLE
Pour Stop Gage
Slab Depth
Overhang (in)
(in)
0 1 2 3 4 5 6 7 8 9 10 11 12
4 20 20 20 20 18 18 16 14 12 12 12 10 10
4 1/4 20 20 20 18 18 16 16 14 12 12 12 10 10
Roof Deck
4 1/2 20 20 20 18 18 16 16 14 12 12 12 10 10
4 3/4 20 20 18 18 16 16 14 14 12 12 10 10 10
5 20 20 18 18 16 16 14 14 12 12 10 10
5 1/4 20 18 18 16 16 14 14 12 12 12 10 10
5 1/2 20 18 18 16 16 14 14 12 12 12 10 10
5 3/4 20 18 16 16 14 14 12 12 12 12 10 10
6 18 18 16 16 14 14 12 12 12 10 10 10
Composite Deck
6 1/4 18 18 16 14 14 12 12 12 12 10 10
6 1/2 18 16 16 14 14 12 12 12 12 10 10
6 3/4 18 16 14 14 14 12 12 12 10 10 10
7 18 16 14 14 12 12 12 12 10 10 10
7 1/4 16 16 14 14 12 12 12 10 10 10
7 1/2 16 14 14 12 12 12 12 10 10 10
7 3/4 16 14 14 12 12 12 10 10 10 10
Versa-Dek®
Long-Span Composite
8 14 14 12 12 12 12 10 10 10
8 1/4 14 14 12 12 12 10 10 10 10
8 1/2 14 12 12 12 12 10 10 10
8 3/4 14 12 12 12 12 10 10 10
Deep-Dek®
9 14 12 12 12 10 10 10
9 1/4 12 12 12 12 10 10 10
9 1/2 12 12 12 10 10 10
9 3/4 12 12 12 10 10 10
10 12 12 10 10 10 10 DESIGN THICKNESS
Form Deck
10 1/4 12 12 10 10 10 Thickness
Gage
10 1/2 12 12 10 10 10 (in)
10 3/4 12 10 10 10 20 0.0358
11 12 10 10 10 18 0.0474
11 1/4 12 10 10 16 0.0598
11 1/2 10 10 10 14 0.0747
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 119
Bill of Materials
Table of Contents
SALESSALES
FAX FAX
BUTLER,
BUTLER, IN (260)IN868-6002
(260) 868-6002
FALLON,
FALLON, NV867-2140
NV (775) (775) 867-2140
HOPE,
HOPE, AR AR722-4262
(870) (870) 722-4262
JUAREZ,
JUAREZ, MX298-4040
MX (915) (915) 298-4040
LAKEFL
LAKE CITY, CITY, FL466-1302
(386) (386) 466-1302
WWW.NEWMILL.COM
WWW.NEWMILL.COM SALEM,SALEM, VA389-0378
VA (540) (540) 389-0378
Roof Deck
https://www.newmill.com/resources/bills-of-materials.html MEMPHIS,
MEMPHIS, TN375-1547
TN (901) (901) 375-1547
DATE:DATE:
DECK
DECK BILL
BILL OF MATERIAL
OF MATERIAL
SHEET:
SHEET: of of
JOB NAME:
JOB NAME: CUST.
CUST. JOB #: JOB #: NMBS
NMBS JOB #: JOB #:
LOCATION:
LOCATION: DETAILER:
DETAILER: CHECKER:
CHECKER:
TYPE: TYPE: GAGE: GAGE: TYPE: TYPE: GAGE: GAGE: TYPE: TYPE: GAGE: GAGE:
COVERAGE:
COVERAGE: FINISH:FINISH: COVERAGE:
COVERAGE: FINISH:FINISH: COVERAGE:
COVERAGE: FINISH:FINISH:
TOTALTOTAL PIECES:
PIECES: TOTALTOTAL PIECES:
PIECES: TOTALTOTAL PIECES:
PIECES:
TOTALTOTAL SQUARES:
SQUARES: TOTALTOTAL SQUARES:
SQUARES: TOTALTOTAL SQUARES:
SQUARES:
General Information
WELD WASHERS:
WELD WASHERS: WELD WASHERS:
WELD WASHERS: WELD WASHERS:
WELD WASHERS:
SCREWS:
SCREWS: SCREWS:
SCREWS: SCREWS:
SCREWS:
SUMP PANS:
SUMP PANS: SUMP PANS:
SUMP PANS: SUMP PANS:
SUMP PANS:
REMARKS:
REMARKS:
Code of Standard Practice
Discover the easiest way to specify Steel Roof and Floor Deck:
120 www.newmill.com/digital-tools
Bill of Materials
Table of Contents
SALES FAX
SALES FAX
BUTLER, IN (260) 868-6002
BUTLER, IN (260) 868-6002
FALLON, NV (775) 867-2140
FALLON, NV (775) 867-2140
HOPE, AR (870)AR
HOPE, 722-4262
(870) 722-4262
JUAREZ,JUAREZ,
MX (915)MX 298-4040
(915) 298-4040
LAKE CITY,
LAKEFL CITY,
(386)FL
466-1302
(386) 466-1302
WWW.NEWMILL.COM
WWW.NEWMILL.COM SALEM, VA (540)VA
SALEM, 389-0378
(540) 389-0378
Roof Deck
https://www.newmill.com/resources/bills-of-materials.html MEMPHIS, TN (901)TN
MEMPHIS, 375-1547
(901) 375-1547
DATE: DATE:
DECK ACCESSORY BILL OF
DECK ACCESSORY MATERIAL
BILL OF MATERIAL
SHEET:SHEET: of of
JOB NAME: JOB NAME: CUST. JOBCUST.
#: JOB #: NMBS JOB#:
NMBS JOB#:
LOCATION: LOCATION: DETAILER:DETAILER: CHECKER:
CHECKER:
Composite Deck
Ridge/Valley Plate (RVPx) Side Closure (SCx) Cell Closure (CCx) Flat Plate (FPx) Filler Sheet (FSx)
Ridge/Valley Plate (RVPx)
Stock Dims: Side Closure (SCx)
Stock Dims: Cell Closure (CCx)
Stock Dims: Flat PlateStock
(FPx)Dims: Filler Sheet
Stock(FSx)
Dims:
Stock Dims: Stock Dims:
RVP1: A & B = 4 1/2", C = 153º SC1: A = 1 1/2", B&C = Stock
1" Dims: CC1: A = 1 1/2", B =Stock1" Dims:FP6: A = 6" Stock Dims:FS1: B = 1 1/2"
RVP2:
RVP1: A & B = 4 1/2", A 153º
C= & B = 6", C = 153º SC1: A = 1 1/2",SC2:
B&CA==1" CC2:
2", B&C = 1" CC1: A = 1 1/2", BA= =1"2", B = 1" FP6: A = 6"FP9: A = 9" FS1: B = 1FS2:
1/2"B = 3"
RVP2: A & B = 6", C = 153º SC3:
SC2: A = 2", B&C A = 3", B&C = 1" CC2: A = 2", B
= 1" CC3:
= 1"A = 3", B = 1" FP9: A = 9"FP12: A = 12", 18 Ga. FS2: B = 3"
SC3: A = 3", B&C = 1" CC3: A = 3", B = 1" FP12: A = 12", 18 Ga.
Notes: All Accessories are 20 gage - U.N.O.
All Accessories
Notes: All Accessories are 20 gageare- U.N.O.
furnished in 10' lengths
All Accessories
All Accessories are in
are furnished G60
10'Galvanized
lengths - Min.
All Stockare
Accessories Items:
G60 Galvanized - Min.
Pour Stop (PSx) Zee Closure (Zx) Girder Filler (GFx)
Stock Dims: Stock Dims: Stock Items:
10-1: #10-16 x 3/4" Type 1 Side Lap
Pour Stop (PSx) Zee Closure (Zx) Girder Filler (GFx)
Versa-Dek®
Long-Span Composite
PS1: A = 3", B = 5" 10-3: #10-16
Typex 13/4" Type
Lap3 Side Lap
Stock Dims: PS2: A = 3 1/2", B = 5" Stock Dims: GF3: A = 4" 10-1: #10-16 x 3/4" Side
12-3: #12-14 x 3/4" Type 3 Side Lap
PS1: A = 3", B = 5" GF6: A = 7", 14 Ga. 10-3: #10-16 x 3/4" Type 3 Side Lap
PS3: A = 4", B = 5" GF3: A = 4" GF9: A = 10", 14 Ga. 12-5: #12-24 x 1 1/4" Type 5 Deck Attachment Screw
PS2: A = 3 1/2", BPS4:
= 5" A = 4 1/2", B = 5", 18 Ga GF6: A = 7", 14 Ga. A = 13", 12 Ga. 12-3: #12-14 x 3/4" Type 3 Side Lap
PS3: A = 4", B = 5" GF12: COL: 12" x 24" Column Closure
PS5: A = 5", B = 5", 18 Ga GF9: A = 10", 14 Ga. 12-5: #12-24 x 1 1/4" Type 5 Deck Attachment Screw
PS4: A = 4 1/2", B = 5", 18 Ga SUMP: 30" x 34" x 14 Gage Standard Sump Pan
GF12: A = 13", 12 Ga. COL: 12" x 24" Column Closure
PS5: A = 5", B = 5", 18 Ga WW: Standard Weld Washer
SUMP: 30" x 34" x 14 Gage Standard Sump Pan
DIMENSIONS WW: Standard Weld Washer
Deep-Dek®
MARK QTY. GAGE REMARKS SEQUENCE
DIMENSIONS
A B C
MARK QTY. GAGE REMARKS SEQUENCE
A B C
Form Deck
Typical Fastener Layouts
General Information
Code of Standard Practice
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 121
Factory Mutual Approved Steel Decks
Table of Contents
New Millennium Building Systems steel roof deck types F (intermediate rib – IR), B (wide rib – WR) and
N (deep rib – DR) are approved for use as a component of Factory Mutual compliant roof systems. New
Millennium decks have been approved in accordance with Factory Mutual, Approval Standard for Steel
Deck as Component of Class 1 Insulated Steel Roof Deck Construction, Class Number 4451 revised 6/2012.
Reference the following tables for approved gages, maximum allowed center-to-center spans and securement
Roof Deck
requirements for Classes 1-60, 1-75 and 1-90. The securement of the roof system must be enhanced at the
building corners and perimeter as outlined in FM Global Property Loss Prevention Data Sheet 1-29.
To ensure availability of material and avoid delays to your project, New Millennium must be informed as early in
the contract process as possible when steel with a minimum yield stress of 80 ksi is determined to be a requirement
by the design professional to satisfy Factory Mutual Data Sheet 1-29, Section 2.2.3, Steel Roof Deck. One of
the design considerations that may require the higher strength steel is when a rating higher than 1-90 is needed.
Composite Deck
Consult the Section noted above for other conditions that may also result in the necessity of this requirement.
F Deck
FM Class 1 - 60 1 - 75 1 - 90
Deck Gage 22 20 18 16 22 20 18 16 22 20 18 16
Single Span 4-4 5-5 6-5 7-3 4-4 5-5 6-5 7-3 4-4 5-5 6-5 7-3
Versa-Dek®
Double Span 5-3 6-6 7-7 8-6 5-3 6-6 7-7 8-6 5-3 6-6 7-7 8-4
Triple Span 5-4 6-7 7-7 8-6 5-4 6-7 7-7 8-6 5-4 6-7 7-7 8-6
B Deck
Form Deck
Deck Gage 22 21 20 19 18 16 22 21 20 19 18 16 22 21 20 19 18 16
Single Span 5 -11 6-3 6-7 7-1 7-7 8-6 5 -11 6-3 6-7 7-1 7-7 8-6 5 -11 6-3 6-7 7-1 7-7 8-6
Double Span 7-0 7-5 7-9 8-4 8 - 11 10 - 0 7-0 7-5 7-9 8-4 8 - 11 10 - 0 7-0 7-5 7-9 8-4 8 - 11 10 - 0
Typical Fastener Layouts
Triple Span 7-0 7-5 7-9 8-4 8 - 11 10 - 0 7-0 7-5 7-9 8-4 8 - 11 10 - 0 7-0 7-5 7-9 8-4 8 - 11 10 - 0
N Deck
Deck Gage 22 21 20 19 18 16 22 21 20 19 18 16 22 21 20 19 18 16
General Information
Single Span 12 - 8 14 - 3 14 - 11 16 - 1 17 - 2 19 - 3 12 - 4 13 - 3 14 - 0 15 - 3 16 - 3 18 - 3 11 - 3 12 - 1 12 - 9 13 - 11 14 - 10 16 - 8
Double Span 13 - 0 14 - 0 14 - 11 16 - 3 17 - 5 19 - 10 11 - 7 12 - 6 13 - 4 14 - 7 15 - 7 17 - 9 10 - 7 11 - 5 12 - 2 13 - 3 14 - 3 16 - 3
Triple Span 14 - 6 15 - 8 16 - 8 18 - 2 19 - 6 22 - 3 13 - 0 14 - 0 14 - 11 16 - 3 17 - 5 19 - 10 11 - 10 12 - 10 13 - 7 14 - 10 15 - 11 18 - 2
Code of Standard Practice
Discover the easiest way to specify Steel Roof and Floor Deck:
122 www.newmill.com/digital-tools
Code of Standard Practice
Table of Contents
Steel decks are considered a structural component of roof and floor systems. Aesthetic conditions
that do not affect the structural performance of the steel deck such as oil canning, minor denting
and damage to shop primer or surface coatings shall not be cause for rejection.
Oil canning (waviness in flat surfaces) is an inherent condition with steel decks that can occur
Roof Deck
during the forming process or from improper installation, especially in lighter gages.
For additional information, reference the Steel Deck Institute’s Code of Standard Practice,
SDI COSP-2017, Section 3.1 and Commentary to SDI COSP-2017, Sections C-3.1.1 and C-3.1.2.
Composite Deck
Below is a link to the Code of Standard Practice
as recommended by the Steel Deck Institute.
Versa-Dek®
Long-Span Composite
https://www.sdi.org/publications-2/publications/
Deep-Dek®
Form Deck
Typical Fastener Layouts
General Information
Code of Standard Practice
Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 123
Building success together
New Millennium is your nationwide resource for the broadest range of
cost-optimized, high-performance structural steel joist and deck solutions.
• Structural steel joists, Joist Girders and deck • BIM-based steel joist and deck design
• Architectural decking solutions • Nationwide manufacturing and availability
• Multi-story long-span composite systems • Design-Build and Integrated Project Delivery (IPD)
• Custom engineering and design assistance • AIA and PDH courses for project optimization
Butler, Indiana Facility Fallon, Nevada Facility Hope, Arkansas Facility Juarez, Mexico Facility
6115 County Road 42 8200 Woolery Way 3565 Highway 32 North Carretera Panamericana 9920
Butler, IN 46721 Fallon, NV 89406 Hope, AR 71801 Colonia Puente Alto 32695
Phone: 260.868.6000 Phone: 775.867.2130 Phone: 870.722.4100 Cd. Juarez, Chihuahua
Fax: 260.868.6001 Fax: 775.867.2169 Fax: 870.722.4245 Phone: 915.298.5050
Fax: 915.298.4040
Lake City, Florida Facility Memphis, Tennessee Facility Salem, Virginia Facility
1992 NW Bascom Norris Drive 4900 Hungerford Road 100 Diuguids Lane Headquarters
Lake City, FL 32055 Memphis, TN 38118 Salem, VA 24153 1690 Broadway
Phone: 386.466.1300 Phone: 901.969.3033 Phone: 540.389.0211 Building 19, Suite 160
Fax: 386.466.1301 Fax: 901.375.1547 Fax: 540.389.0378 Fort Wayne, IN 46802
Phone: 260.321.8080