NM Roof Floor Deck Load Table

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 124

INTERACTIVE PDF

VERSION 5.0

Design Guide
Steel Roof
and Floor Deck
Table of Contents
Roof Deck
Composite Deck
Deep-Dek®
Long-Span Composite
Versa-Dek®
Form Deck
Typical Fastener Layouts
General Information

This catalog was produced by New Millennium to assist specifiers and consumers
in the application of deck products produced by New Millennium.

LIABILITY STATEMENT
Code of Standard Practice

The data published in this design guide has been developed using recognized engineering principles and is intended for general information only.
Although the data shown is believed to be accurate, New Millennium Building Systems does not assume any liability or obligation of any kind or nature
arising from or related to the data provided herein and/or its use. Applicability of the products and the accuracy of the data should be assessed by a
licensed professional engineer or architect to determine the suitability for the intended application. New Millennium Building Systems’ Standard Terms
and Conditions shall supersede any statements to the contrary contained herein.
Table of Contents
Table of Contents

Roof Deck
Roof Deck. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.0RD Deck.......................................................................................................................... 6
F Deck................................................................................................................................... 7

Composite Deck
B Deck..........................................................................................................................8 – 13
NW32® and N Deck............................................................................................... 14 – 26
Curve-Dek................................................................................................................. 27 – 30
Versa-Dek®................................................................................................................ 31 – 36
Super Versa-Dek®..................................................................................................... 37 – 38
Deep-Dek®................................................................................................................ 39 – 57

Versa-Dek®
Long-Span Composite
Composite Deck. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Standard Composite................................................................................................ 60 – 67

Deep-Dek®
Cellular Composite................................................................................................... 68 – 91

Long-Span Composite Deck. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92


Versa-Dek® Composite.....................................................................................................92
Deep-Dek® Composite......................................................................................................93

Form Deck
Form Deck. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
0.6 and 1.0 Form Deck............................................................................................ 96 – 99
EHD-Dek............................................................................................................... 100 – 101
1.5, 2.0, and 3.0 Form Deck............................................................................... 102 – 109

Typical Fastener Layouts


Typical Fastener Layouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110

General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112


Floor Deck Design............................................................................................................114
Web Crippling Support Reactions..................................................................................115
Fire Resistance Ratings.....................................................................................................116
General Information

Standard Accessories.......................................................................................................117
Floor Deck Accessory Details..........................................................................................118
Pour Stop Gage Selection...............................................................................................119
Bill of Materials...................................................................................................... 120 – 121
Factory Mutual Approved Steel Decks.......................................................................... 122
Code of Standard Practice

Code of Standard Practice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 3
Long-Span Composite
Code of Standard Practice General Information Typical Fastener Layouts Form Deck Composite Deck Roof Deck Table of Contents
Versa-Dek® Deep-Dek®

Roof Deck
Table of Contents
Roof deck is available in a range of profiles and options. Deck products meet
required steel deck certifications and are manufactured in accordance with the
specifications of the Steel Deck Institute. Click on the links below to view load tables.

Roof Deck
1.0RD Deck........................................................................................................................... 6
1-inch standard and vented deck available

F Deck..................................................................................................................................... 7

Composite Deck
B Deck.............................................................................................................................8 – 9
Standard, interlocking, and vented variations,
available with or without acoustical properties

B-Dek Cellular and B-Dek Cellular Acoustical............................................ 10 – 13

Versa-Dek®
Long-Span Composite
NW32®.........................................................................................................................14 –17
Standard and interlocking available,
with or without acoustical properties

Deep-Dek®
Standard N Deck................................................................................................... 18 – 19
Standard and acoustical available

N-Dek.........................................................................................................................20 – 26
Standard, cellular, and inverted variations,

Form Deck
available with or without acoustical properties

Curve-Dek®..............................................................................................................27 – 30
Standard and cellular variations, available
with or without acoustical properties

Typical Fastener Layouts


Versa-Dek® 2.0....................................................................................................... 31 – 34
2-inch dovetail deck, available with
or without acoustical properties

Versa-Dek® 3.5.......................................................................................................35 – 36
3.5-inch dovetail deck, available with
or without acoustical properties
General Information
Super Versa-Dek® 6.5.....................................................................................37 – 38
A dovetail hybrid structural deck, available
with or without acoustical properties

Deep-Dek®......................................................................................................... 39 – 44
4.5-inch, 6-inch, and 7.5-inch single cell (hat) unit deck,
available with or without acoustical properties
Code of Standard Practice

Deep-Dek® Cellular..........................................................................................45 – 57
4.5-inch, 6-inch, and 7.5-inch single cell (hat) unit deck with
a liner panel, available with or without acoustical properties

newmill.com 5
1.0RD, 1.0RDV Deck
Table of Contents

Roof Decks - Types 1.0RD, 1.0RDV


PROPERTIES
Thickness Cover Weight
Gage 2 87 ˝
(in) (in) (psf)
26 0.0179 0.94 1˝
24 0.0238 1.24 1 81 ˝ 4˝
36
22 0.0295 1.54 36˝ Coverage
Roof Deck

20 0.0358 1.87
ICC-ES APPROVED
REFER TO ESR-3818

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
26 60 0.042 0.042 0.041 0.041 0.068 0.071 2428 2547 1663 466 828
Composite Deck

24 60 0.056 0.056 0.056 0.056 0.098 0.105 3518 3782 2739 789 1422
22 60 0.070 0.070 0.070 0.070 0.129 0.132 4631 4744 3388 1169 2126
20 60 0.085 0.085 0.085 0.085 0.160 0.160 5749 5749 4101 1665 3047
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

3 -0 3 -6 4 -0 4 -6 5 -0 5 -6 6 -0 6 -6 7 -0 8 -0 (ctr / ctr)
26 180 / 101 132 / 64 101 / 43 - - - - - - - 4-0
24 261 / 137 191 / 86 147 / 58 116 / 41 94 / 30 78 / 22 65 / 17 - - - 5-9
Single
22 343 / 170 252 / 107 193 / 72 152 / 50 123 / 37 102 / 28 86 / 21 73 / 17 63 / 13 48 / 9 7-6
20 426 / 206 313 / 130 240 / 87 189 / 61 153 / 45 127 / 33 106 / 26 91 / 20 78 / 16 60 / 11 9-2
26 185 / 244 136 / 154 105 / 103 83 / 72 67 / 53 - - - - - 4 - 11
Form Deck

24 275 / 331 203 / 208 156 / 139 124 / 98 100 / 71 83 / 54 70 / 41 59 / 32 51 / 26 - 7-0


Double
22 345 / 410 255 / 258 196 / 173 155 / 121 126 / 89 104 / 67 87 / 51 75 / 40 64 / 32 49 / 22 9-2
20 418 / 497 309 / 313 237 / 210 188 / 147 152 / 107 126 / 81 106 / 62 90 / 49 78 / 39 60 / 26 11 - 2
26 229 / 191 169 / 120 130 / 81 103 / 57 84 / 41 - - - - - 5-0
24 341 / 259 252 / 163 194 / 109 154 / 77 125 / 56 103 / 42 87 / 32 74 / 25 64 / 20 49 / 14 7-2
Triple
22 428 / 321 316 / 202 243 / 135 193 / 95 157 / 69 130 / 52 109 / 40 93 / 32 80 / 25 62 / 17 9-3
Typical Fastener Layouts

20 518 / 389 383 / 245 295 / 164 234 / 115 190 / 84 157 / 63 132 / 49 113 / 38 97 / 31 75 / 21 11 - 4
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
0-9 0-9 0-9 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
26 60
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
24 60 0 - 11 0 - 11 0 - 11 than the maximum design or construction spans shown in table above
22 60 1-0 1-0 1-0 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

20 60 1-2 1-2 1-2 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
6 www.newmill.com/digital-tools
F Deck

Table of Contents
Roof Decks - Type F
PROPERTIES
7
Thickness Cover Weight 18 ˝
Gage
(in) (in) (psf)
22 0.0295 1.58 1 21 ˝
5 6˝
20 0.0358 1.92 8˝
36
18 0.0474 2.54 36˝ Coverage

Roof Deck
16 0.0598 3.21
ICC-ES APPROVED
REFER TO ESR-3818

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.121 0.128 0.118 0.128 0.110 0.121 2629 2890 2132 622 1144

Composite Deck
20 40 0.151 0.155 0.149 0.155 0.136 0.146 3266 3494 2579 887 1641
18 40 0.205 0.205 0.205 0.205 0.186 0.192 4447 4595 3395 1483 2761
16 40 0.259 0.259 0.259 0.259 0.238 0.240 5700 5755 4257 2269 4240
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
4 -0 4 -6 5 -0 5 -6 6 -0 6 -6 7 -0 8 -0 9 -0 10 - 0 (ctr / ctr)
22 110 / 124 87 / 87 - - - - - - - - 4-3
20 136 / 155 108 / 109 87 / 79 72 / 60 - - - - - - 5-3
Single
18 185 / 210 146 / 147 119 / 107 98 / 81 82 / 62 70 / 49 61 / 39 46 / 26 - - 7-1
16 238 / 265 188 / 186 152 / 136 126 / 102 106 / 78 90 / 62 78 / 49 59 / 33 47 / 23 - 8 - 10
22 119 / 316 94 / 222 77 / 162 63 / 122 - - - - - - 5-3

Form Deck
20 144 / 383 114 / 269 93 / 196 77 / 147 64 / 114 55 / 89 - - - - 6-6
Double
18 190 / 507 150 / 356 122 / 260 101 / 195 85 / 150 72 / 118 62 / 95 48 / 63 38 / 45 - 8-8
16 237 / 639 188 / 449 153 / 327 126 / 246 106 / 189 90 / 149 78 / 119 60 / 80 47 / 56 38 / 41 10 - 9
22 148 / 247 118 / 174 95 / 127 79 / 95 - - - - - - 5-4
20 179 / 300 142 / 211 115 / 154 96 / 115 80 / 89 69 / 70 59 / 56 - - - 6-7
Triple
18 236 / 397 187 / 279 152 / 203 126 / 153 106 / 118 90 / 92 78 / 74 60 / 50 47 / 35 - 8-9

Typical Fastener Layouts


16 296 / 500 234 / 351 190 / 256 157 / 192 132 / 148 113 / 117 97 / 93 75 / 62 59 / 44 48 / 32 10 - 11
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans. General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
1-1 1-1 1-1 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
22 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20 40 1-4 1-4 1-4 than the maximum design or construction spans shown in table above
18 40 1-9 1-9 1-9 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

16 40 2-2 2-2 2-2 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 7
B, BI, BV, BIV Deck
Table of Contents

Roof Decks - Types B, BI, BV, BIV


PROPERTIES 2 21 ˝
Thickness Cover Weight
Gage
(in) (in) (psf)
22 0.0295 1.63 1 21 ˝
20 0.0358 1.98 6˝
36 1 85 ˝
18 0.0474 2.62
Roof Deck

16 0.0598 3.30 36˝ Coverage


ICC-ES APPROVED
REFER TO ESR-3818

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.163 0.175 0.157 0.175 0.176 0.183 4215 4391 2009 654 1181
Composite Deck

20 40 0.205 0.213 0.201 0.213 0.224 0.235 5375 5624 2428 932 1696
18 40 0.280 0.281 0.279 0.281 0.304 0.315 7291 7553 3192 1557 2858
16 40 0.355 0.355 0.355 0.355 0.390 0.395 9332 9454 3996 2381 4396
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

5 -0 5 -6 6 -0 6 -6 7 -0 8 -0 9 -0 10 - 0 11 - 0 12 - 0 (ctr / ctr)
22 112 / 86 93 / 64 78 / 50 67 / 39 57 / 31 - - - - - 6 - 10
20 143 / 107 118 / 81 100 / 62 85 / 49 73 / 39 56 / 26 44 / 18 - - - 8-7
Single
18 194 / 147 161 / 110 135 / 85 115 / 67 99 / 54 76 / 36 60 / 25 49 / 18 40 / 14 34 / 11 11 - 3
16 249 / 186 206 / 140 173 / 108 147 / 85 127 / 68 97 / 45 77 / 32 62 / 23 51 / 17 43 / 13 13 - 11
22 115 / 221 95 / 166 80 / 128 69 / 101 59 / 81 45 / 54 36 / 38 - - - 8-4
Form Deck

20 147 / 269 122 / 202 103 / 156 88 / 122 76 / 98 58 / 66 46 / 46 37 / 34 31 / 25 - 10 - 6


Double
18 198 / 356 164 / 267 138 / 206 118 / 162 102 / 130 78 / 87 62 / 61 50 / 44 41 / 33 35 / 26 13 - 9
16 247 / 448 205 / 337 173 / 260 147 / 204 127 / 163 98 / 109 77 / 77 63 / 56 52 / 42 44 / 32 16 - 11
22 143 / 173 119 / 130 100 / 100 85 / 79 74 / 63 57 / 42 45 / 30 - - - 8-6
20 183 / 211 152 / 158 128 / 122 109 / 96 94 / 77 72 / 51 57 / 36 47 / 26 39 / 20 - 10 - 8
Triple
18 245 / 278 203 / 209 172 / 161 147 / 127 127 / 101 97 / 68 77 / 48 63 / 35 52 / 26 43 / 20 13 - 11
Typical Fastener Layouts

16 307 / 351 255 / 264 215 / 203 183 / 160 159 / 128 122 / 86 96 / 60 78 / 44 65 / 33 54 / 25 17 - 1
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
1-8 1-8 1-8 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
22 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20 40 2-0 1 - 11 1 - 11 than the maximum design or construction spans shown in table above
18 40 2-6 2-3 2-3 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

16 40 3-1 2-7 2-7 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
8 www.newmill.com/digital-tools
BA, BIA Deck

Table of Contents
Roof Decks - Types BA, BIA
PROPERTIES 2 21 ˝
Thickness Cover Weight
Gage
(in) (in) (psf)
22 0.0295 1.56 1 21 ˝
20 0.0358 1.89 6˝
36 1 85 ˝
18 0.0474 2.50

Roof Deck
16 0.0598 3.16 36˝ Coverage
ICC-ES APPROVED
REFER TO ESR-3818

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.159 0.170 0.153 0.169 0.170 0.174 4073 4158 1352 627 1174

Composite Deck
20 40 0.200 0.206 0.196 0.206 0.217 0.223 5198 5353 1631 898 1687
18 40 0.272 0.273 0.272 0.273 0.293 0.301 7013 7201 2136 1508 2845
16 40 0.344 0.344 0.344 0.344 0.373 0.376 8935 9015 2664 2314 4378
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers applied in accordance with
SDI white paper ''Perforated Metal Deck Design with Commentary''.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
5 -0 5 -6 6 -0 6 -6 7 -0 8 -0 9 -0 10 - 0 11 - 0 12 - 0 (ctr / ctr)
22 109 / 83 90 / 63 75 / 48 64 / 38 55 / 30 - - - - - 6-7
20 139 / 105 115 / 79 96 / 61 82 / 48 71 / 38 54 / 26 43 / 18 - - - 8-4
Single
18 187 / 143 155 / 107 130 / 83 111 / 65 95 / 52 73 / 35 58 / 24 47 / 18 39 / 13 - 10 - 11
16 238 / 180 197 / 136 165 / 104 141 / 82 122 / 66 93 / 44 74 / 31 60 / 23 49 / 17 41 / 13 13 - 5
22 107 / 214 89 / 161 75 / 124 64 / 98 56 / 78 43 / 52 34 / 37 - - - 8-1

Form Deck
20 138 / 261 114 / 196 97 / 151 83 / 119 71 / 95 55 / 64 44 / 45 35 / 33 29 / 25 - 10 - 2
Double
18 185 / 345 154 / 259 130 / 200 111 / 157 96 / 126 74 / 84 59 / 59 48 / 43 39 / 32 33 / 25 13 - 4
16 231 / 435 192 / 327 163 / 252 139 / 198 120 / 159 92 / 106 73 / 75 60 / 54 49 / 41 41 / 31 16 - 4
22 132 / 168 110 / 126 93 / 97 80 / 76 69 / 61 53 / 41 42 / 29 - - - 8-2
20 170 / 204 141 / 153 120 / 118 102 / 93 89 / 74 68 / 50 54 / 35 44 / 26 36 / 19 - 10 - 4
Triple
18 227 / 270 190 / 203 160 / 156 137 / 123 119 / 98 92 / 66 73 / 46 59 / 34 49 / 25 41 / 20 13 - 6

Typical Fastener Layouts


16 285 / 340 237 / 256 201 / 197 172 / 155 149 / 124 115 / 83 91 / 58 74 / 43 61 / 32 52 / 25 16 - 6
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans. General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
1-7 1-7 1-7 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
22 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20 40 1 - 11 1 - 10 1 - 10 than the maximum design or construction spans shown in table above
18 40 2-5 2-2 2-2 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

16 40 3-0 2-7 2-6 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 9
B-Dek Cellular
Table of Contents

Roof Decks - Type BDC Cellular


PROPERTIES
Gage Thickness Cover Weight 6˝
6˝ 2 21˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 3.55 1 21 ˝
20/18 0.0358/0.0474 4.09
24.5 185 ˝
18/20 0.0474/0.0358 4.16
24 21 ˝ Coverag
Roof Deck

18/18 0.0474/0.0474 4.70 24 21 ˝ Coverage


ICC-ES APPROVED
REFER TO ESR-1169

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 40 0.399 0.409 0.383 0.397 0.303 0.437 7256 10456 2303 915 1618
Composite Deck

20/18 40 0.438 0.466 0.420 0.462 0.315 0.456 7538 10921 2303 915 1618
18/20 40 0.510 0.510 0.502 0.476 0.444 0.563 10635 13480 3028 1530 2745
18/18 40 0.561 0.562 0.552 0.554 0.459 0.587 10987 14049 3028 1530 2745
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

6 -0 7 -0 8 -0 9 -0 10 - 0 11 -0 12 - 0 13 - 0 14 - 0 15 - 0 (ctr / ctr)
20/20 134 / 121 99 / 76 76 / 51 60 / 36 48 / 26 40 / 20 - - - - 11 - 0
20/18 140 / 133 103 / 84 79 / 56 62 / 39 50 / 29 42 / 22 35 / 17 - - - 11 - 3
Single
18/20 197 / 155 145 / 97 111 / 65 88 / 46 71 / 33 59 / 25 49 / 19 42 / 15 36 / 12 32 / 10 15 - 3
18/18 203 / 170 149 / 107 114 / 72 90 / 50 73 / 37 61 / 28 51 / 21 43 / 17 37 / 13 33 / 11 15 - 5
20/20 185 / 299 137 / 188 106 / 126 84 / 89 68 / 65 57 / 49 48 / 37 41 / 29 35 / 24 - 13 - 4
Form Deck

20/18 192 / 341 143 / 215 110 / 144 88 / 101 71 / 74 59 / 55 50 / 43 43 / 34 37 / 27 - 13 - 8


Double
18/20 238 / 373 177 / 235 137 / 157 109 / 110 88 / 81 73 / 61 62 / 47 53 / 37 45 / 29 40 / 24 18 - 5
18/18 248 / 411 184 / 259 142 / 173 113 / 122 92 / 89 76 / 67 64 / 51 55 / 40 47 / 32 41 / 26 18 - 8
20/20 210 / 234 154 / 147 118 / 99 93 / 69 76 / 51 62 / 38 52 / 29 45 / 23 39 / 18 - 13 - 6
20/18 218 / 267 160 / 168 123 / 113 97 / 79 79 / 58 65 / 43 55 / 33 46 / 26 40 / 21 - 13 - 10
Triple
18/20 293 / 292 218 / 184 169 / 123 135 / 86 110 / 63 91 / 47 77 / 36 66 / 29 57 / 23 49 / 19 18 - 8
Typical Fastener Layouts

18/18 303 / 322 227 / 203 176 / 136 140 / 95 114 / 69 95 / 52 79 / 40 68 / 32 58 / 25 51 / 21 18 - 11


Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
3-6 2-9 2-9 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20/20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20/18 40 3-9 3-0 3-0 than the maximum design or construction spans shown in table above
18/20 40 4-5 3-2 3-2 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

18/18 40 4-6 3-6 3-5 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
10 www.newmill.com/digital-tools
B-Dek Cellular

Table of Contents
Roof Decks - Type BDC Cellular
PROPERTIES 6˝
6˝ 2 21˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)
1 21 ˝
18/16 0.0474/0.0598 5.28
16/18 0.0598/0.0474 24.5 5.35 185 ˝
24 21 ˝ Coverag
16/16 0.0598/0.0598 5.93 24 21 ˝ Coverage

Roof Deck
ICC-ES APPROVED
REFER TO ESR-1169

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 40 0.608 0.627 0.598 0.627 0.471 0.609 11279 14580 3028 1530 2745

Composite Deck
16/18 40 0.677 0.677 0.676 0.643 0.631 0.724 15108 17337 3790 2342 4241
16/16 40 0.735 0.735 0.734 0.730 0.648 0.751 15519 17978 3790 2342 4241
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
6 -0 7 -0 8 -0 9 -0 10 -0 11 - 0 12 -0 13 -0 14 -0 15 -0 (ctr / ctr)
18/16 209 / 185 153 / 116 117 / 78 93 / 55 75 / 40 62 / 30 52 / 23 44 / 18 38 / 15 33 / 12 15 - 7
Single 16/18 280 / 205 206 / 129 157 / 87 124 / 61 101 / 44 83 / 33 70 / 26 60 / 20 51 / 16 45 / 13 19 - 10
16/16 287 / 223 211 / 141 162 / 94 128 / 66 103 / 48 86 / 36 72 / 28 61 / 22 53 / 18 46 / 14 19 - 11
18/16 256 / 459 191 / 289 147 / 193 117 / 136 95 / 99 79 / 74 67 / 57 57 / 45 49 / 36 43 / 29 18 - 9
Double 16/18 306 / 495 228 / 312 176 / 209 140 / 147 114 / 107 94 / 80 79 / 62 68 / 49 58 / 39 51 / 32 23 - 10

Form Deck
16/16 316 / 538 235 / 339 182 / 227 145 / 159 118 / 116 97 / 87 82 / 67 70 / 53 61 / 42 53 / 34 23 - 10
18/16 313 / 359 234 / 226 182 / 151 145 / 106 117 / 78 97 / 58 82 / 45 70 / 35 60 / 28 52 / 23 19 - 0
Triple 16/18 375 / 388 280 / 244 217 / 164 173 / 115 141 / 84 117 / 63 99 / 48 84 / 38 73 / 31 63 / 25 24 - 1
16/16 387 / 421 290 / 265 224 / 178 179 / 125 146 / 91 121 / 68 102 / 53 87 / 41 75 / 33 66 / 27 24 - 2
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.

Typical Fastener Layouts


4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.

General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
4-7 3-9 3-9 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
18/16 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
16/18 40 4-8 4-0 3 - 11 than the maximum design or construction spans shown in table above
16/16 40 4-9 4-5 4-3 ● Bearing width at perimeter support assumed to be 3'' minimum
● Design total uniform load of 45 psf in conjuncon with a 100 lb.
Code of Standard Practice

concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 11
B-Dek Cellular Acoustical
Table of Contents

Roof Decks - Type BDCA Cellular


PROPERTIES
Gage Thickness Cover Weight 6˝ 2 21 ˝
6˝ 2 21˝
(Hat/Pan) (in) (in) (psf)
1 21 ˝
20/20 0.0358/0.0358 1 21 ˝ 3.41
20/18 0.0358/0.0474 3.91 185 ˝
185 ˝ 24.5
18/20 0.0474/0.0358 4.02 24 21 ˝ Coverage
Roof Deck

24 21 ˝ Coverage ICC-ES APPROVED


18/18 0.0474/0.0474 4.51
REFER TO ESR-1169

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 40 0.388 0.404 0.373 0.397 0.301 0.437 7207 10460 2303 915 1618
Composite Deck

20/18 40 0.426 0.459 0.409 0.459 0.313 0.456 7489 10914 2303 915 1618
18/20 40 0.495 0.495 0.487 0.476 0.441 0.563 10561 13487 3028 1530 2745
18/18 40 0.544 0.554 0.536 0.550 0.456 0.586 10913 14044 3028 1530 2745
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

6 -0 7 -0 8 -0 9 -0 10 - 0 11 -0 12 - 0 13 - 0 14 - 0 15 - 0 (ctr / ctr)
20/20 133 / 118 98 / 74 75 / 50 59 / 35 48 / 25 40 / 19 - - - - 10 - 11
20/18 139 / 129 102 / 81 78 / 55 62 / 38 50 / 28 41 / 21 35 / 16 - - - 11 - 2
Single
18/20 196 / 150 144 / 95 110 / 63 87 / 44 70 / 32 58 / 24 49 / 19 42 / 15 36 / 12 31 / 10 15 - 3
18/18 202 / 165 148 / 104 114 / 70 90 / 49 73 / 36 60 / 27 51 / 21 43 / 16 37 / 13 32 / 11 15 - 5
20/20 185 / 296 137 / 186 106 / 125 84 / 88 69 / 64 57 / 48 48 / 37 41 / 29 35 / 23 - 13 - 4
Form Deck

20/18 192 / 336 143 / 212 110 / 142 88 / 100 71 / 73 59 / 55 50 / 42 43 / 33 37 / 26 - 13 - 7


Double
18/20 239 / 362 177 / 228 137 / 153 109 / 107 88 / 78 73 / 59 62 / 45 53 / 36 45 / 28 40 / 23 18 - 5
18/18 248 / 405 184 / 255 142 / 171 113 / 120 92 / 88 76 / 66 64 / 51 55 / 40 47 / 32 41 / 26 18 - 8
20/20 209 / 232 153 / 146 117 / 98 93 / 69 75 / 50 62 / 38 52 / 29 44 / 23 38 / 18 - 13 - 6
20/18 217 / 263 159 / 166 122 / 111 96 / 78 78 / 57 64 / 43 54 / 33 46 / 26 40 / 21 - 13 - 10
Triple
18/20 293 / 283 219 / 178 169 / 119 135 / 84 110 / 61 91 / 46 76 / 35 65 / 28 56 / 22 49 / 18 18 - 8
Typical Fastener Layouts

18/18 303 / 317 227 / 200 176 / 134 140 / 94 114 / 69 94 / 51 79 / 40 67 / 31 58 / 25 51 / 20 18 - 11


Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
3-5 2-9 2-9 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20/20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20/18 40 3-9 2 - 11 2 - 11 than the maximum design or construction spans shown in table above
18/20 40 4-4 3-2 3-2 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

18/18 40 4-6 3-5 3-5 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
12 www.newmill.com/digital-tools
B-Dek Cellular Acoustical

Table of Contents
Roof Decks - Type BDCA Cellular
PROPERTIES Roof Decks - Type

BDCA Cellular
6˝ 2 21 ˝
PROPERTIES
Gage 2 21˝
Thickness Cover Weight
(Hat/Pan)
Gage (in)
Thickness (in) 1 Weight
Cover (psf) 1 21 ˝
12 ˝
18/16 0.0474/0.0598
(Top/Bot) (in) (in) 5.05
(psf)
185 ˝
16/18 185 ˝
18/16 0.0598/0.0474
0.0474/0.0598 24.5 5.16
5.05
1 24 21 ˝ Coverage
16/18 0.0598/0.0598
24 2 ˝ Coverage
16/16 0.0598/0.0474 24.5 5.70
5.16

Roof Deck
ICC-ES APPROVED
16/16 0.0598/0.0598 5.70 REFER TO ESR-1169

Available with optional plastic lath to protect acoustical properties of the deck when painting in the field.

ASD SECTION PROPERTIES DESIGN STRENGTHS


ASD
Gage
Fy ID 1 Span PROPERTIES
SECTION ID 2+ Span Ip In Sp Sn
DESIGN
Mn,p/Ω STRENGTHS
Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
4 4 4 4 3 3
(ksi)
Fy (in /ft) (in /ft)
ID 1 Span ID 2+ Span (in /ft)
Ip (in /ft)
In (in /ft)
Sp (in /ft)
Sn (in-lb/ft) (in-lb/ft)
Mn,p/Ω Mn,n/Ω (lb/ft)
Vn/Ω (lb/ft)
*Rbe/Ω (lb/ft)
*Rbi/Ω
Gage
18/16 40
(ksi) 0.591
(in 4
/ft) 0.609
(in 4
/ft) 0.582
(in 4
/ft) 0.609
(in 4
/ft) 0.469
(in 3
/ft) 0.608
(in 3 11243
/ft) (in-lb/ft) 14558
(in-lb/ft) 3028
(lb/ft) 1530
(lb/ft) 2745
(lb/ft)

Composite Deck
16/18
18/16 40
40 0.657
0.591 0.657
0.609 0.655
0.582 0.640
0.609 0.626
0.469 0.724
0.608 15001
11243 17336
14558 3790
3028 2342
1530 4241
2745
16/16
16/18 40
40 0.713
0.657 0.717
0.657 0.712
0.655 0.717
0.640 0.643
0.626 0.750
0.724 15412
15001 17957
17336 3790
3790 2342
2342 4241
4241
16/16 40 0.713 1. Section
Notes: 0.717 properties
0.712are calculated
0.717 in accordance
0.643 with the
0.750 15412
AISI S100-16, 17957 modifiers.
with perforation 3790 2342 4241
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM
ALLOWABLE UNIFORM LOADS
LOADS AND
AND MAXIMUM
MAXIMUM CONSTRUCTION
CONSTRUCTION SPANS
SPANS
AllowableUniform
Allowable UniformTotal
TotalLoad
Load(psf)
(psf)//Load
Loadthat
thatProduces
ProducesL/240
L/240Deflection
Deflection(psf)
(psf) SDI Max.
SDI Max.
Span
Span Constr.
Constr.
Gage
Gage Centerto
Center toCenter
CenterSpan
Span(ft
(ft--in)
in)
Condition
Condition Span
Span

Deep-Dek®
66 -- 00 77 -- 00 88 -- 00 99 -- 00 10 -- 00
10 11 -- 00
11 12 -- 00
12 13 -- 00
13 14 -- 00
14 15 -- 00
15 (ctr // ctr)
(ctr ctr)
18/16
18/16 208 // 179
208 179 153 // 113
153 113 117 // 76
117 76 93 // 53
93 53 75 // 39
75 39 62 // 29
62 29 52
52 // 22
22 44 // 18
44 18 38 // 14
38 14 33 // 11
33 11 18--78
15
Single
Single 16/18
16/18 278 // 199
278 199 204 // 125
204 125 156 // 84
156 84 123 // 59
123 59 100 // 43
100 43 83 // 32
83 32 69
69 // 25
25 59 // 20
59 20 51 // 16
51 16 44 // 13
44 13 25- -10
19 0
16/16
16/16 285 // 216
285 216 210 // 136
210 136 161 // 91
161 91 127 // 64
127 64 103 // 47
103 47 85 // 35
85 35 71
71 // 27
27 61 // 21
61 21 52 // 17
52 17 46 // 14
46 14 25- -11
19 8
18/16
18/16 256 // 446
256 446 190 // 281
190 281 147 // 188
147 188 117 // 132
117 132 95 // 96
95 96 79 // 72
79 72 66
66 // 56
56 57 // 44
57 44 49 // 35
49 35 43 // 29
43 29 23- -10
18 0
Double
Double 16/18
16/18 306 // 481
306 481 228 // 303
228 303 176 // 203
176 203 140 // 142
140 142 114 // 104
114 104 94 // 78
94 78 79
79 // 60
60 68 // 47
68 47 58 // 38
58 38 51 // 31
51 31 30- -10
23 9

Form Deck
16/16
16/16 316 /
316 / 524524 235 /
235 / 330330 182 /
182 / 221221 144 /
144 / 155155 117 / 113
117 / 113 97 /
97 / 8585 82 /
82 / 6666 70 /
70 / 5252 60 /
60 / 4141 53 /
53 / 3434 31 -
23 - 117
18/16
18/16 313 // 349
313 349 234 // 220
234 220 182 // 147
182 147 145 // 103
145 103 117 // 75
117 75 97 // 57
97 57 81
81 // 44
44 69 // 34
69 34 60 // 27
60 27 52 // 22
52 22 23--15
19
Triple
Triple 16/18
16/18 375 // 376
375 376 280 // 237
280 237 217 // 159
217 159 173 // 111
173 111 141 // 81
141 81 117 // 61
117 61 99
99 // 47
47 84 // 37
84 37 73 // 30
73 30 63 // 24
63 24 31--23
24
16/16
16/16 387 // 410
387 410 289 // 258
289 258 224 // 173
224 173 179 // 122
179 122 146 // 89
146 89 121 // 67
121 67 102
102 // 51
51 87 // 40
87 40 75 // 32
75 32 66 // 26
66 26 32--21
24
Notes: 3.3. Allowable
Notes: AllowableUniform
UniformLoads
Loadsand
andmaximum
maximumconstruction
constructionspans
spansshown
shownare
arebased
basedon
onthe
thefollowing
followingcriteria:
criteria:
●● ANSI/SDI
ANSI/SDIRD-2017
RD-2017Standard
StandardforforSteel
SteelRoof
RoofDeck
Deck
●● Minimum
Minimumbearing
bearinglengths
lengthsofof111/2''
1/2''for
forend
endbearing
bearingandand3''
3''for
forinterior
interiorbearing.
bearing. Check
Checkwebwebcrippling
cripplingififminimums
minimumsare arenot
notmet.
met.

Typical Fastener Layouts


4. Maximum
4. Maximumconstruction
constructionspans
spansshown
showninclude
includeaacheck
checkfor
fordeck
a nominal 200 lbs.
self-weight concentrated
plus a nominal 200 load supported
lbs. by a one
concentrated loadfoot sectionby
supported of adeck
oneper
footSDI criteria,
section of
which
deck exceeds
per the IBC
SDI criteria requirement
which of aIBC
exceeds the 300requirement
lbs. roof maintenance
of a 300 lbs.load
roofdistributed
maintenance overload
an area of 2 1/2over
distributed feetan
byarea
2 1/2offeet perfeet
2 1/2 Section
by 2 1/2 feet per
1607.4 1607.4
Section and Tableand1607.1.
Table 1607.1.
5. ''Load
5. Valuesthat
in RED are shown
Produces L/240for use in determining
Deflection'' deckin
values shown capacity underthe
RED exceed deflection limits
''Allowable more stringent
Uniform thanThese
Total Load''. Span/240.
loads The
maytotal loads
be used toshown
are not tothe
determine be exceeded.
deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See
6. Deck lengthsatover
website 40'-0'' require inquiry
www.newmill.com and special
for Factory Mutualaccommodations.
approved deck types Please
andcontact
maximum New FMMillennium
constructionfor spans.
further information.
7. Top and bottom sections are supplied with galvanized finish. Only the exposed side of bottom sections are available with an additional
finish of gray primer.
8. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


F Back-Span Condition Notes:
MAXIMUM
Gage CANTILEVER
y
SPANS
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
Fy Back-Span Condition Notes:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
Gage
18/16 40 4-7 3-8 3-8
(ksi) Single Double Triple 9. ●Maximum
Adjacentcantilever spanstoshown
span assumed are based
be at least on longer
3 mes the following
than thecriteria:
canlever and no greater
16/18 40 4-8 3 - 11 3 - 10 ● than
ANSI/SDI RD-2017 Standard
the maximum design orfor Steel Roof spans
construction Deck shown in table above
18/16 40 4-7 3-8 3-8
16/16 40 4-9 4-3 4-2 ●● Bearing
Adjacent spanatassumed
width to be
perimeter at least
support 3 mesto
assumed longer
be 3''than the canlever and no greater
minimum
16/18 40 4-8 3 - 11 3 - 10 than the maximum
● Design total uniformdesign
load ofor45construction spans shown
psf in conjuncon with a in
100table
lb. above
16/16 40 4-9 4-3 4-2 ● concentrated
Bearing widthload.
at perimeter support assumed to be 3'' minimum
Code of Standard Practice

● Design total uniform load of 45 psf in conjuncon with a 100 lb.


concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 13
NW32®
Table of Contents

Roof Decks - Type NW32


PROPERTIES
Thickness Cover Weight
Gage
(in) (in) (psf)
22 0.0295 1.86
20 0.0358 2.26
32
18 0.0474 2.99
Roof Deck

ICC-ES APPROVED
16 0.0598 3.76 REFER TO ESR-4655

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 50 0.694 0.755 0.649 0.741 0.352 0.386 10546 11548 2184 539 1087
Composite Deck

20 50 0.875 0.935 0.836 0.926 0.457 0.496 13691 14842 3779 777 1559
18 50 1.213 1.254 1.192 1.252 0.672 0.711 20109 21279 6618 1317 2624
16 50 1.568 1.581 1.561 1.581 0.902 0.937 27015 28060 9158 2032 4030
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 - 0 20 - 0 (ctr / ctr)
22 110 / 89 70 / 45 58 / 34 49 / 26 42 / 21 36 / 17 31 / 13 27 / 11 - - 17 - 6
20 143 / 112 91 / 57 75 / 43 63 / 33 54 / 26 47 / 21 41 / 17 36 / 14 28 / 10 23 / 7 22 - 9
Single
18 209 / 155 134 / 80 111 / 60 93 / 46 79 / 36 68 / 29 60 / 24 52 / 19 41 / 14 34 / 10 33 - 6
16 281 / 201 180 / 103 149 / 77 125 / 59 107 / 47 92 / 37 80 / 30 70 / 25 56 / 18 45 / 13 40 - 0
22 109 / 233 75 / 119 62 / 90 53 / 69 45 / 54 39 / 43 34 / 35 30 / 29 24 / 20 - 21 - 7
Form Deck

20 151 / 289 98 / 148 81 / 111 68 / 85 58 / 67 50 / 54 44 / 44 38 / 36 30 / 25 25 / 18 28 - 1


Double
18 219 / 387 141 / 198 116 / 149 98 / 115 83 / 90 72 / 72 63 / 59 55 / 48 44 / 34 35 / 25 40 - 0
16 289 / 488 186 / 250 154 / 188 129 / 145 110 / 114 95 / 91 83 / 74 73 / 61 58 / 43 47 / 31 40 - 0
22 123 / 182 93 / 93 77 / 70 65 / 54 56 / 43 48 / 34 42 / 28 - - - 21 - 11
20 177 / 226 121 / 116 101 / 87 85 / 67 72 / 53 62 / 42 55 / 34 - - - 28 - 6
Triple
18 272 / 303 175 / 155 145 / 117 122 / 90 104 / 71 90 / 57 78 / 46 - - - 40 - 0
Typical Fastener Layouts

16 359 / 382 231 / 196 191 / 147 161 / 113 137 / 89 119 / 71 103 / 58 - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for a nominal 200 lbs. concentrated load supported by a one foot section of deck per SDI criteria,
which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per Section
1607.4 and Table 1607.1.
5. Values in RED are shown for use in determining deck capacity under deflection limits more stringent than Span/240. The total loads shown
are not to be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
4-3 4-2 4-1 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
22 50
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20 50 5-3 5-3 4-4 than the maximum design or construction spans shown in table above
18 50 5-8 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

16 50 6-0 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
14 www.newmill.com/digital-tools
NW32A®

Table of Contents
Roof Decks - Type NW32A
PROPERTIES
Thickness Cover Weight
Gage
(in) (in) (psf)
22 0.0295 1.76
20 0.0358 2.14
32
18 0.0474 2.82

Roof Deck
ICC-ES APPROVED
16 0.0598 3.56 REFER TO ESR-4655

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 50 0.673 0.733 0.629 0.718 0.335 0.361 10024 10805 1637 511 1080

Composite Deck
20 50 0.850 0.908 0.813 0.900 0.438 0.470 13099 14085 2832 742 1550
18 50 1.181 1.219 1.161 1.218 0.649 0.680 19423 20354 4958 1267 2610
16 50 1.526 1.537 1.520 1.537 0.874 0.900 26176 26954 6857 1965 4012
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers applied in accordance with
SDI white paper ''Perforated Metal Deck Design with Commentary''.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
8 -0 10 -0 11 -0 12 -0 13 - 0 14 -0 15 -0 16 -0 18 - 0 20 - 0 (ctr / ctr)
22 104 / 86 67 / 44 55 / 33 46 / 26 40 / 20 34 / 16 30 / 13 26 / 11 - - 16 - 8
20 136 / 109 87 / 56 72 / 42 61 / 32 52 / 25 45 / 20 39 / 17 34 / 14 27 / 10 - 21 - 9
Single
18 202 / 151 129 / 77 107 / 58 90 / 45 77 / 35 66 / 28 58 / 23 51 / 19 40 / 13 32 / 10 32 - 4
16 273 / 195 175 / 100 144 / 75 121 / 58 103 / 46 89 / 36 78 / 30 68 / 24 54 / 17 44 / 13 40 - 0
22 106 / 226 69 / 116 58 / 87 49 / 67 42 / 53 36 / 42 31 / 34 28 / 28 22 / 20 - 20 - 6

Form Deck
20 142 / 280 92 / 144 76 / 108 64 / 83 55 / 65 47 / 52 41 / 43 36 / 35 29 / 25 23 / 18 26 - 10
Double
18 207 / 376 134 / 193 111 / 145 93 / 112 80 / 88 69 / 70 60 / 57 53 / 47 42 / 33 34 / 24 39 - 10
16 275 / 475 177 / 243 147 / 183 124 / 141 105 / 111 91 / 89 79 / 72 70 / 59 55 / 42 45 / 30 40 - 0
22 123 / 177 86 / 91 71 / 68 60 / 52 52 / 41 45 / 33 39 / 27 - - - 20 - 10
20 175 / 219 114 / 112 95 / 84 80 / 65 68 / 51 59 / 41 51 / 33 - - - 27 - 3
Triple
18 257 / 295 166 / 151 138 / 113 116 / 87 99 / 69 86 / 55 75 / 45 - - - 40 - 0

Typical Fastener Layouts


16 341 / 371 220 / 190 183 / 143 154 / 110 131 / 87 113 / 69 99 / 56 - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for a nominal 200 lbs. concentrated load supported by a one foot section of deck per SDI criteria,
which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per Section
1607.4 and Table 1607.1.
5. Values in RED are shown for use in determining deck capacity under deflection limits more stringent than Span/240. The total loads shown
are not to be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans. General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
4-0 4-0 4-0 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
22 50
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20 50 5-1 5-1 4-4 than the maximum design or construction spans shown in table above
18 50 5-8 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

16 50 6-0 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 15
NW32I®
Table of Contents

Roof Decks - Type NW32I


PROPERTIES
Thickness Cover Weight
Gage
(in) (in) (psf)
22 0.0295 1.88
20 0.0358 2.28
32
18 0.0474 3.02
Roof Deck

ICC-ES APPROVED
16 0.0598 3.80 REFER TO ESR-4655

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 50 0.687 0.762 0.642 0.754 0.348 0.405 10420 12117 2184 539 1087
Composite Deck

20 50 0.864 0.936 0.826 0.933 0.451 0.514 13517 15383 3779 777 1559
18 50 1.199 1.242 1.178 1.242 0.663 0.721 19856 21582 6618 1317 2624
16 50 1.549 1.562 1.543 1.562 0.890 0.934 26654 27967 9158 2032 4030
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 - 0 20 - 0 (ctr / ctr)
22 109 / 88 69 / 45 57 / 34 48 / 26 41 / 20 35 / 16 31 / 13 27 / 11 - - 17 - 4
20 141 / 111 90 / 57 74 / 43 63 / 33 53 / 26 46 / 21 40 / 17 35 / 14 28 / 10 23 / 7 22 - 6
Single
18 207 / 154 132 / 79 109 / 59 92 / 45 78 / 36 68 / 29 59 / 23 52 / 19 41 / 13 33 / 10 33 - 1
16 278 / 198 178 / 102 147 / 76 123 / 59 105 / 46 91 / 37 79 / 30 69 / 25 55 / 17 44 / 13 40 - 0
22 109 / 235 79 / 120 65 / 90 55 / 70 47 / 55 41 / 44 35 / 36 31 / 29 25 / 21 - 21 - 4
Form Deck

20 156 / 289 101 / 148 84 / 111 71 / 86 60 / 67 52 / 54 45 / 44 40 / 36 32 / 25 26 / 18 27 - 8


Double
18 222 / 384 143 / 196 118 / 148 99 / 114 85 / 89 73 / 72 64 / 58 56 / 48 44 / 34 36 / 25 40 - 0
16 288 / 482 185 / 247 153 / 186 129 / 143 110 / 112 95 / 90 83 / 73 73 / 60 57 / 42 47 / 31 40 - 0
22 123 / 184 97 / 94 81 / 71 68 / 55 58 / 43 51 / 34 44 / 28 - - - 21 - 8
20 177 / 226 126 / 116 104 / 87 88 / 67 75 / 53 65 / 42 56 / 34 - - - 28 - 1
Triple
18 275 / 300 178 / 154 147 / 115 124 / 89 106 / 70 91 / 56 79 / 46 - - - 40 - 0
Typical Fastener Layouts

16 358 / 377 230 / 193 191 / 145 161 / 112 137 / 88 118 / 70 103 / 57 - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for a nominal 200 lbs. concentrated load supported by a one foot section of deck per SDI criteria,
which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per Section
1607.4 and Table 1607.1.
5. Values in RED are shown for use in determining deck capacity under deflection limits more stringent than Span/240. The total loads shown
are not to be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
4-5 4-2 4-1 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
22 50
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20 50 5-4 5-4 4-4 than the maximum design or construction spans shown in table above
18 50 5-8 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

16 50 6-0 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
16 www.newmill.com/digital-tools
NW32IA®

Table of Contents
Roof Decks - Type NW32IA
PROPERTIES
Thickness Cover Weight
Gage
(in) (in) (psf)
22 0.0295 1.78
20 0.0358 2.16
32
18 0.0474 2.86

Roof Deck
ICC-ES APPROVED
16 0.0598 3.60 REFER TO ESR-4655

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 50 0.666 0.740 0.622 0.732 0.331 0.384 9902 11498 1637 511 1080

Composite Deck
20 50 0.840 0.909 0.803 0.906 0.432 0.490 12930 14663 2832 742 1550
18 50 1.167 1.208 1.147 1.208 0.640 0.691 19172 20687 4958 1267 2610
16 50 1.507 1.519 1.502 1.519 0.862 0.898 25816 26881 6857 1965 4012
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers applied in accordance with
SDI white paper ''Perforated Metal Deck Design with Commentary''.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 - 0 20 - 0 (ctr / ctr)
22 103 / 85 66 / 44 55 / 33 46 / 25 39 / 20 34 / 16 29 / 13 26 / 11 - - 16 - 6
20 135 / 108 86 / 55 71 / 41 60 / 32 51 / 25 44 / 20 38 / 16 34 / 13 27 / 9 - 21 - 6
Single
18 200 / 149 128 / 77 106 / 57 89 / 44 76 / 35 65 / 28 57 / 23 50 / 19 39 / 13 32 / 10 31 - 11
16 269 / 193 172 / 99 142 / 74 120 / 57 102 / 45 88 / 36 76 / 29 67 / 24 53 / 17 43 / 12 40 - 0
22 108 / 228 74 / 117 61 / 88 52 / 68 44 / 53 38 / 43 33 / 35 29 / 29 23 / 20 - 20 - 3

Form Deck
20 147 / 281 96 / 144 79 / 108 67 / 83 57 / 65 49 / 52 43 / 43 38 / 35 30 / 25 24 / 18 26 - 6
Double
18 211 / 373 136 / 191 113 / 143 95 / 110 81 / 87 70 / 70 61 / 57 54 / 47 42 / 33 34 / 24 39 - 4
16 274 / 469 177 / 240 146 / 180 123 / 139 105 / 109 91 / 87 79 / 71 70 / 59 55 / 41 45 / 30 40 - 0
22 123 / 179 90 / 91 75 / 69 64 / 53 55 / 42 47 / 33 41 / 27 - - - 20 - 7
20 176 / 220 118 / 112 98 / 85 83 / 65 71 / 51 61 / 41 54 / 33 - - - 26 - 11
Triple
18 261 / 292 169 / 149 140 / 112 118 / 86 101 / 68 87 / 54 76 / 44 - - - 39 - 11

Typical Fastener Layouts


16 340 / 367 220 / 188 182 / 141 154 / 109 131 / 86 113 / 68 99 / 56 - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for a nominal 200 lbs. concentrated load supported by a one foot section of deck per SDI criteria,
which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per Section
1607.4 and Table 1607.1.
5. Values in RED are shown for use in determining deck capacity under deflection limits more stringent than Span/240. The total loads shown
are not to be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans. General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
4-2 4-1 4-0 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
22 50
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20 50 5-3 5-2 4-4 than the maximum design or construction spans shown in table above
18 50 5-8 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

16 50 6-0 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 17
Standard N Deck
Table of Contents

Roof Decks - Type N


PROPERTIES
2 85 ˝ Cover
Thickness Weight 2 85 ˝
Gage
(in) (in) (psf)
22 0.0295 2.05 3˝ 3˝
20 0.0358 8˝2.48 8˝
187 ˝ 24 187 ˝
18 0.0474 3.29
Roof Deck

ICC-ES APPROVED
16 0.0598
24˝ Coverage 4.14 24˝ Coverage REFER TO ESR-3818

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.759 0.886 0.690 0.881 0.372 0.427 8900 10216 2439 462 909
Composite Deck

20 40 0.968 1.085 0.908 1.083 0.487 0.544 11654 13030 3592 666 1308
18 40 1.352 1.440 1.309 1.440 0.687 0.753 16456 18039 5663 1128 2208
16 40 1.768 1.814 1.745 1.814 0.890 0.951 21312 22767 7115 1740 3400
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

8 -0 10 -0 11 -0 12 - 0 13 -0 14 -0 15 - 0 16 - 0 18 - 0 20 - 0 (ctr / ctr)
22 93 / 97 59 / 50 49 / 37 41 / 29 35 / 23 30 / 18 - - - - 13 - 10
20 121 / 124 78 / 63 64 / 48 54 / 37 46 / 29 40 / 23 35 / 19 30 / 15 24 / 11 - 17 - 6
Single
18 171 / 173 110 / 89 91 / 67 76 / 51 65 / 40 56 / 32 49 / 26 43 / 22 34 / 15 27 / 11 23 - 0
16 222 / 226 142 / 116 117 / 87 99 / 67 84 / 53 72 / 42 63 / 34 55 / 28 44 / 20 36 / 14 27 - 7
22 91 / 274 67 / 140 56 / 105 47 / 81 40 / 64 34 / 51 30 / 42 26 / 34 - - 16 - 10
Form Deck

20 131 / 335 86 / 172 71 / 129 60 / 99 51 / 78 44 / 63 38 / 51 34 / 42 27 / 29 - 21 - 3


Double
18 185 / 445 119 / 228 99 / 171 83 / 132 71 / 104 61 / 83 53 / 67 47 / 56 37 / 39 30 / 28 27 - 9
16 234 / 560 150 / 287 125 / 215 105 / 166 89 / 131 77 / 105 67 / 85 59 / 70 47 / 49 38 / 36 33 - 0
22 103 / 214 83 / 110 69 / 82 58 / 63 50 / 50 43 / 40 37 / 32 - - - 17 - 1
20 149 / 262 107 / 134 89 / 101 75 / 78 64 / 61 55 / 49 48 / 40 - - - 21 - 6
Triple
18 230 / 348 148 / 178 123 / 134 103 / 103 88 / 81 76 / 65 66 / 53 - - - 28 - 1
Typical Fastener Layouts

16 291 / 438 187 / 224 155 / 169 131 / 130 111 / 102 96 / 82 84 / 67 - - - 33 - 5
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
3-9 3-9 3-9 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
22 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20 40 4-8 4-8 4-4 than the maximum design or construction spans shown in table above
18 40 5 - 10 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

16 40 6-2 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
18 www.newmill.com/digital-tools
Standard N Deck Acoustical

Table of Contents
Roof Decks - Type NA
PROPERTIES
Thickness Cover Weight 2 85 ˝ 2 85 ˝
Gage
(in) (in) (psf)
22 0.0295 1.92 3˝ 3˝
20 0.0358 2.33 8˝ 8˝
24 187 ˝ 187 ˝
18 0.0474 3.08

Roof Deck
ICC-ES APPROVED
16 0.0598 3.88 24˝ Coverage 24˝ Coverage
REFER TO ESR-3818

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.713 0.829 0.649 0.823 0.340 0.378 8144 9053 1602 428 901

Composite Deck
20 40 0.911 1.016 0.856 1.014 0.450 0.492 10780 11773 2357 623 1297
18 40 1.274 1.349 1.237 1.349 0.638 0.685 15276 16414 3709 1066 2192
16 40 1.664 1.700 1.647 1.700 0.823 0.865 19702 20730 4649 1658 3378
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers applied in accordance with
SDI white paper ''Perforated Metal Deck Design with Commentary''.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
8 -0 10 -0 11 -0 12 -0 13 -0 14 - 0 15 - 0 16 - 0 18 - 0 20 - 0 (ctr / ctr)
22 85 / 91 54 / 47 45 / 35 38 / 27 32 / 21 - - - - - 12 - 9
20 112 / 117 72 / 60 59 / 45 50 / 35 43 / 27 37 / 22 32 / 18 28 / 15 - - 16 - 4
Single
18 159 / 163 102 / 84 84 / 63 71 / 48 60 / 38 52 / 30 45 / 25 40 / 20 31 / 14 25 / 10 21 - 9
16 205 / 213 131 / 109 109 / 82 91 / 63 78 / 50 67 / 40 58 / 32 51 / 27 41 / 19 33 / 14 26 - 2
22 90 / 256 59 / 131 49 / 98 41 / 76 35 / 60 30 / 48 26 / 39 23 / 32 - - 15 - 7

Form Deck
20 119 / 314 77 / 161 64 / 121 54 / 93 46 / 73 40 / 59 35 / 48 30 / 39 24 / 28 - 19 - 11
Double
18 167 / 416 108 / 213 89 / 160 75 / 123 64 / 97 55 / 78 48 / 63 42 / 52 34 / 37 27 / 27 26 - 3
16 210 / 525 136 / 269 113 / 202 95 / 155 81 / 122 70 / 98 61 / 80 54 / 66 42 / 46 34 / 34 31 - 4
22 102 / 200 73 / 103 60 / 77 51 / 59 44 / 47 38 / 37 33 / 30 - - - 15 - 10
20 146 / 246 95 / 126 79 / 94 67 / 73 57 / 57 49 / 46 43 / 37 - - - 20 - 2
Triple
18 206 / 326 134 / 167 111 / 125 93 / 97 80 / 76 69 / 61 60 / 49 - - - 26 - 8

Typical Fastener Layouts


16 260 / 411 169 / 210 140 / 158 118 / 122 101 / 96 87 / 77 76 / 62 - - - 31 - 9
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans. General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
3-4 3-4 3-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
22 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20 40 4-3 4-3 4-3 than the maximum design or construction spans shown in table above
18 40 5-9 5-9 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

16 40 6-1 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 19
N-Dek
Table of Contents

Roof Decks - Type ND


PROPERTIES
2 85 ˝
Thickness Cover Weight 2 85 ˝
Gage
(in) (in) (psf)
22 0.0295 2.04 3˝ 3˝
20 0.0358 8˝ 2.47 8˝
187 ˝
0.0474
24
3.27
187 ˝
18
Roof Deck

16 24˝ Coverage
0.0598 4.13 24˝ Coverage ICC-ES APPROVED
REFER TO ESR-1169

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.725 0.850 0.655 0.843 0.363 0.453 8692 10848 2434 464 923
Composite Deck

20 40 0.928 1.043 0.868 1.040 0.477 0.563 11413 13484 3585 668 1325
18 40 1.297 1.386 1.253 1.386 0.683 0.752 16356 18023 5620 1131 2232
16 40 1.698 1.747 1.674 1.747 0.887 0.948 21249 22708 7062 1745 3430
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

8 -0 10 -0 11 -0 12 - 0 13 -0 14 -0 15 - 0 16 - 0 18 - 0 20 - 0 (ctr / ctr)
22 91 / 93 58 / 48 48 / 36 40 / 27 34 / 22 30 / 17 - - - - 13 - 6
20 119 / 119 76 / 61 63 / 46 53 / 35 45 / 28 39 / 22 34 / 18 30 / 15 23 / 10 - 17 - 2
Single
18 170 / 166 109 / 85 90 / 64 76 / 49 65 / 39 56 / 31 48 / 25 43 / 21 34 / 15 27 / 11 22 - 11
16 221 / 217 142 / 111 117 / 84 98 / 64 84 / 51 72 / 41 63 / 33 55 / 27 44 / 19 35 / 14 27 - 6
22 92 / 262 71 / 134 59 / 101 50 / 78 42 / 61 37 / 49 32 / 40 28 / 33 22 / 23 - 16 - 6
Form Deck

20 133 / 322 89 / 165 74 / 124 62 / 95 53 / 75 46 / 60 40 / 49 35 / 40 28 / 28 - 20 - 10


Double
18 185 / 428 119 / 219 99 / 165 83 / 127 71 / 100 61 / 80 53 / 65 47 / 53 37 / 38 30 / 27 27 - 8
16 233 / 539 150 / 276 124 / 207 104 / 160 89 / 126 77 / 101 67 / 82 59 / 67 47 / 47 38 / 35 33 - 0
22 105 / 205 84 / 105 73 / 79 62 / 61 53 / 48 46 / 38 40 / 31 - - - 16 - 9
20 151 / 252 110 / 129 92 / 97 77 / 75 66 / 59 57 / 47 50 / 38 - - - 21 - 2
Triple
18 230 / 335 148 / 171 123 / 129 103 / 99 88 / 78 76 / 62 66 / 51 - - - 28 - 0
Typical Fastener Layouts

16 290 / 422 187 / 216 155 / 162 130 / 125 111 / 98 96 / 79 84 / 64 - - - 33 - 5


Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
4-0 4-0 4-0 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
22 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20 40 4 - 10 4 - 10 4-4 than the maximum design or construction spans shown in table above
18 40 5 - 10 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

16 40 6-2 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
20 www.newmill.com/digital-tools
NA-Dek

Table of Contents
Roof Decks - Type NDA
PROPERTIES
Thickness Cover Weight 2 85 ˝ 2 85 ˝
Gage
(in) (in) (psf)
22 0.0295 1.82 3˝ 3˝
20 0.0358 2.21 8˝ 8˝
0.0474
24
2.92 187 ˝ 187 ˝
18

Roof Deck
16 0.0598 3.68 24˝ Coverage 24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-1169

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.674 0.796 0.606 0.789 0.330 0.419 7901 10035 1716 248 514

Composite Deck
20 40 0.867 0.978 0.809 0.975 0.437 0.522 10456 12503 2525 399 807
18 40 1.217 1.301 1.175 1.301 0.631 0.699 15107 16738 3952 752 1507
16 40 1.596 1.640 1.574 1.640 0.822 0.881 19699 21104 4957 1226 2477
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
8 -0 10 -0 11 -0 12 -0 13 -0 14 - 0 15 - 0 16 - 0 18 - 0 20 - 0 (ctr / ctr)
22 62 / 86 50 / 44 44 / 33 37 / 26 31 / 20 - - - - - 12 - 5
20 100 / 111 70 / 57 58 / 43 48 / 33 41 / 26 36 / 21 31 / 17 27 / 14 - - 16 - 0
Single
18 157 / 156 101 / 80 83 / 60 70 / 46 60 / 36 51 / 29 45 / 24 39 / 19 31 / 14 25 / 10 21 - 8
16 205 / 204 131 / 105 109 / 79 91 / 61 78 / 48 67 / 38 58 / 31 51 / 26 41 / 18 33 / 13 26 - 4
22 51 / 246 41 / 126 37 / 95 34 / 73 32 / 57 29 / 46 27 / 37 26 / 31 - - 15 - 2

Form Deck
20 81 / 302 65 / 155 59 / 116 54 / 89 49 / 70 42 / 56 37 / 46 32 / 38 26 / 26 - 19 - 5
Double
18 151 / 402 110 / 206 91 / 154 77 / 119 65 / 94 56 / 75 49 / 61 43 / 50 34 / 35 28 / 26 26 - 3
16 215 / 506 139 / 259 115 / 195 97 / 150 82 / 118 71 / 94 62 / 77 55 / 63 43 / 44 35 / 32 31 - 8
22 58 / 192 47 / 98 42 / 74 39 / 57 36 / 45 33 / 36 31 / 29 - - - 15 - 5
20 92 / 236 73 / 121 67 / 91 61 / 70 56 / 55 52 / 44 46 / 36 - - - 19 - 9
Triple
18 171 / 314 136 / 161 113 / 121 95 / 93 81 / 73 70 / 59 61 / 48 - - - 26 - 7

Typical Fastener Layouts


16 266 / 396 172 / 203 143 / 152 120 / 117 103 / 92 89 / 74 77 / 60 - - - 32 - 1
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans. General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
2-4 2-1 1 - 11 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
22 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20 40 4-6 4-6 4-4 than the maximum design or construction spans shown in table above
18 40 5-9 5 - 10 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

16 40 6-1 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 21
N-Dek Cellular
Table of Contents

Roof Decks - Type NDC Cellular


PROPERTIES
Gage Thickness Cover Weight 2 85 ˝ 187 ˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 3.96 3˝
20/18 0.0358/0.0474 4.49
24.5 8˝
18/20 0.0474/0.0358 4.70
Roof Deck

1
18/18 0.0474/0.0474 5.24 24 2 ˝ Coverage ICC-ES APPROVED
REFER TO ESR-1169

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 40 1.619 1.788 1.451 1.703 0.554 1.005 13269 24062 3512 668 1325
Composite Deck

20/18 40 1.760 2.037 1.569 1.984 0.552 1.043 13220 24990 3512 668 1325
18/20 40 2.106 2.154 1.972 2.044 0.832 1.281 19926 30686 5505 1131 2232
18/18 40 2.300 2.447 2.148 2.368 0.853 1.350 20432 32325 5505 1131 2232
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 -0 20 - 0 (ctr / ctr)
20/20 138 / 207 88 / 106 73 / 80 61 / 61 52 / 48 45 / 39 39 / 31 35 / 26 27 / 18 - 18 - 8
20/18 138 / 225 88 / 115 73 / 87 61 / 67 52 / 53 45 / 42 39 / 34 34 / 28 27 / 20 - 18 - 3
Single
18/20 208 / 270 133 / 138 110 / 104 92 / 80 79 / 63 68 / 50 59 / 41 52 / 34 41 / 24 33 / 17 25 - 6
18/18 213 / 295 136 / 151 113 / 113 95 / 87 81 / 69 69 / 55 61 / 45 53 / 37 42 / 26 34 / 19 25 - 6
20/20 133 / 552 106 / 283 96 / 212 88 / 164 82 / 129 76 / 103 70 / 84 61 / 69 49 / 48 39 / 35 22 - 6
Form Deck

20/18 133 / 629 106 / 322 96 / 242 88 / 186 82 / 147 76 / 117 70 / 95 61 / 79 48 / 55 39 / 40 22 - 0


Double
18/20 223 / 665 179 / 340 162 / 256 139 / 197 119 / 155 103 / 124 90 / 101 79 / 83 63 / 58 51 / 43 30 - 6
18/18 223 / 756 179 / 387 162 / 291 147 / 224 125 / 176 108 / 141 95 / 115 83 / 94 66 / 66 53 / 48 30 - 5
20/20 151 / 432 120 / 221 110 / 166 96 / 128 82 / 101 71 / 81 61 / 66 - - - 22 - 9
20/18 151 / 492 120 / 252 110 / 189 96 / 146 81 / 115 70 / 92 61 / 75 - - - 22 - 3
Triple
18/20 254 / 520 203 / 266 172 / 200 144 / 154 123 / 121 106 / 97 92 / 79 - - - 30 - 11
Typical Fastener Layouts

18/18 254 / 591 203 / 303 176 / 227 148 / 175 126 / 138 109 / 110 95 / 90 - - - 30 - 10
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
5 - 11 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20/20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20/18 40 6 - 11 5 - 11 4-4 than the maximum design or construction spans shown in table above
18/20 40 6-5 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

18/18 40 6-7 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
22 www.newmill.com/digital-tools
N-Dek Cellular

Table of Contents
Roof Decks - Type NDC Cellular
PROPERTIES
Gage Thickness Cover Weight 2 85 ˝ 187 ˝
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 5.81 3˝
16/18 0.0598/0.0474 24.5 6.03

16/16 0.0598/0.0598 6.61

Roof Deck
1
24 2 ˝ Coverage ICC-ES APPROVED
REFER TO ESR-1169

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 40 2.472 2.734 2.302 2.695 0.871 1.393 20863 33373 5505 1131 2232

Composite Deck
16/18 40 2.858 2.858 2.757 2.746 1.176 1.670 28173 39999 6918 1745 3430
16/16 40 3.083 3.184 2.970 3.122 1.201 1.724 28766 41303 6918 1745 3430
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 - 0 18 -0 20 -0 (ctr / ctr)
18/16 217 / 317 139 / 162 115 / 122 97 / 94 82 / 74 71 / 59 62 / 48 54 / 40 43 / 28 35 / 20 25 - 4
Single 16/18 293 / 366 188 / 187 155 / 141 130 / 108 111 / 85 96 / 68 83 / 56 73 / 46 58 / 32 47 / 23 31 - 9
16/16 300 / 395 192 / 202 158 / 152 133 / 117 113 / 92 98 / 74 85 / 60 75 / 49 59 / 35 48 / 25 31 - 6
18/16 223 / 844 179 / 432 162 / 325 149 / 250 129 / 197 112 / 158 98 / 128 86 / 106 68 / 74 55 / 54 30 - 3
Double 16/18 343 / 882 259 / 452 215 / 339 182 / 261 155 / 206 134 / 165 117 / 134 103 / 110 82 / 77 66 / 56 37 - 7

Form Deck
16/16 343 / 983 267 / 503 222 / 378 187 / 291 160 / 229 138 / 183 121 / 149 106 / 123 84 / 86 68 / 63 37 - 4
18/16 254 / 661 203 / 338 180 / 254 151 / 196 129 / 154 111 / 123 97 / 100 - - - 30 - 7
Triple 16/18 390 / 690 293 / 354 243 / 266 204 / 205 174 / 161 150 / 129 130 / 105 - - - 38 - 1
16/16 390 / 769 300 / 394 248 / 296 208 / 228 177 / 179 153 / 144 133 / 117 - - - 37 - 9
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.

Typical Fastener Layouts


4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.

General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
7 - 10 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
18/16 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
16/18 40 7 - 11 5 - 11 4-4 than the maximum design or construction spans shown in table above
16/16 40 8-0 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
● Design total uniform load of 45 psf in conjuncon with a 100 lb.
Code of Standard Practice

concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 23
N-Dek Cellular Acoustical
Table of Contents

Roof Decks - Type NDCA Cellular


PROPERTIES
Gage Thickness Cover Weight 2 85 ˝ 187 ˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 3.80

20/18 0.0358/0.0474 4.28
24.5
18/20 0.0474/0.0358 4.54 8˝
Roof Deck

18/18 0.0474/0.0474 5.03 1 ICC-ES APPROVED


24 2 ˝ Coverage
REFER TO ESR-1169

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 40 1.567 1.764 1.407 1.702 0.556 1.005 13319 24066 3512 668 1325
Composite Deck

20/18 40 1.706 2.005 1.524 1.972 0.553 1.043 13249 24975 3512 668 1325
18/20 40 2.036 2.126 1.909 2.043 0.824 1.283 19736 30733 5505 1131 2232
18/18 40 2.225 2.410 2.080 2.357 0.845 1.349 20246 32312 5505 1131 2232
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 -0 20 - 0 (ctr / ctr)
20/20 139 / 201 89 / 103 73 / 77 62 / 59 53 / 47 45 / 37 39 / 30 35 / 25 27 / 18 - 18 - 9
20/18 138 / 218 88 / 112 73 / 84 61 / 65 52 / 51 45 / 41 39 / 33 35 / 27 27 / 19 - 18 - 5
Single
18/20 206 / 261 132 / 133 109 / 100 91 / 77 78 / 61 67 / 49 58 / 40 51 / 33 41 / 23 33 / 17 25 - 6
18/18 211 / 285 135 / 146 112 / 110 94 / 84 80 / 66 69 / 53 60 / 43 53 / 36 42 / 25 34 / 18 25 - 6
20/20 133 / 545 106 / 279 96 / 209 88 / 161 82 / 127 76 / 102 70 / 83 62 / 68 49 / 48 39 / 35 22 - 8
Form Deck

20/18 133 / 619 106 / 317 96 / 238 88 / 183 82 / 144 76 / 115 70 / 94 61 / 77 48 / 54 39 / 40 22 - 2


Double
18/20 223 / 656 179 / 336 162 / 252 140 / 194 119 / 153 103 / 122 90 / 100 79 / 82 63 / 58 51 / 42 30 - 6
18/18 223 / 744 179 / 381 162 / 286 147 / 220 125 / 173 108 / 139 94 / 113 83 / 93 66 / 65 53 / 48 30 - 6
20/20 151 / 426 120 / 218 110 / 164 96 / 126 82 / 99 71 / 80 62 / 65 - - - 23 - 0
20/18 151 / 484 120 / 248 110 / 186 96 / 144 82 / 113 70 / 90 61 / 73 - - - 22 - 6
Triple
18/20 254 / 514 203 / 263 170 / 198 143 / 152 122 / 120 105 / 96 91 / 78 - - - 30 - 11
Typical Fastener Layouts

18/18 254 / 582 203 / 298 174 / 224 146 / 173 125 / 136 108 / 109 94 / 88 - - - 30 - 10
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
5 - 11 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20/20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20/18 40 6-1 5 - 11 4-4 than the maximum design or construction spans shown in table above
18/20 40 6-4 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

18/18 40 6-6 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
24 www.newmill.com/digital-tools
N-Dek Cellular Acoustical

Table of Contents
Roof Decks - Type NDCA Cellular
PROPERTIES
Gage Thickness Cover Weight 2 85 ˝ 187 ˝
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 5.55 3˝
16/18 0.0598/0.0474 24.5 5.82
16/16 0.0598/0.0598 6.34 8˝

Roof Deck
1 ICC-ES APPROVED
24 2 ˝ Coverage
REFER TO ESR-1169

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 40 2.394 2.684 2.232 2.667 0.863 1.391 20682 33328 5505 1131 2232

Composite Deck
16/18 40 2.760 2.808 2.665 2.737 1.165 1.670 27909 39989 6918 1745 3430
16/16 40 2.979 3.127 2.872 3.095 1.190 1.722 28506 41257 6918 1745 3430
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 - 0 18 -0 20 -0 (ctr / ctr)
18/16 215 / 306 138 / 157 114 / 118 96 / 91 82 / 71 70 / 57 61 / 46 54 / 38 43 / 27 34 / 20 25 - 5
Single 16/18 291 / 353 186 / 181 154 / 136 129 / 105 110 / 82 95 / 66 83 / 54 73 / 44 57 / 31 47 / 23 31 - 9
16/16 297 / 381 190 / 195 157 / 147 132 / 113 112 / 89 97 / 71 84 / 58 74 / 48 59 / 33 48 / 24 31 - 7
18/16 223 / 828 179 / 424 162 / 319 149 / 245 129 / 193 112 / 155 97 / 126 86 / 104 68 / 73 55 / 53 30 - 4
Double 16/18 343 / 867 259 / 444 215 / 333 182 / 257 155 / 202 134 / 162 117 / 132 103 / 108 82 / 76 66 / 55 37 - 8

Form Deck
16/16 343 / 966 267 / 494 222 / 371 187 / 286 160 / 225 138 / 180 121 / 146 106 / 121 84 / 85 68 / 62 37 - 5
18/16 254 / 648 203 / 332 178 / 249 150 / 192 127 / 151 110 / 121 96 / 98 - - - 30 - 9
Triple 16/18 390 / 678 291 / 347 240 / 261 202 / 201 172 / 158 148 / 127 129 / 103 - - - 38 - 2
16/16 390 / 756 297 / 387 245 / 291 206 / 224 176 / 176 151 / 141 132 / 115 - - - 37 - 11
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.

Typical Fastener Layouts


4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.

General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
7 - 10 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
18/16 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
16/18 40 7 - 11 5 - 11 4-4 than the maximum design or construction spans shown in table above
16/16 40 8-0 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
● Design total uniform load of 45 psf in conjuncon with a 100 lb.
Code of Standard Practice

concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 25
Inverted N-Dek
Table of Contents

Roof Decks - Type NDR


PROPERTIES
1
6Thickness
8˝ Cover Weight 681 ˝
Gage
(in) (in) (psf)
22 0.0295 2.04
3˝ 3˝
20 0.0358 2.47
24
583 ˝ 18 0.0474 3.27 583 ˝
Roof Deck

8˝ 8˝
16 0.0598 4.13
24˝ Coverage 24˝ Coverage

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.850 0.850 0.843 0.655 0.453 0.363 10848 8692 2434 464 923
Composite Deck

20 40 1.043 1.043 1.040 0.868 0.563 0.477 13484 11413 3585 668 1325
18 40 1.386 1.386 1.386 1.253 0.752 0.683 18023 16356 5620 1131 2232
16 40 1.747 1.747 1.747 1.674 0.948 0.887 22708 21249 7062 1745 3430
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

8 -0 10 -0 11 -0 12 - 0 13 -0 14 -0 15 -0 16 -0 18 -0 20 - 0 (ctr / ctr)
22 113 / 109 72 / 56 60 / 42 50 / 32 43 / 25 37 / 20 32 / 17 28 / 14 22 / 10 - 16 - 7
20 140 / 134 90 / 68 74 / 51 62 / 40 53 / 31 46 / 25 40 / 20 35 / 17 28 / 12 - 19 - 11
Single
18 188 / 177 120 / 91 99 / 68 83 / 53 71 / 41 61 / 33 53 / 27 47 / 22 37 / 16 30 / 11 24 - 11
16 237 / 224 151 / 114 125 / 86 105 / 66 90 / 52 77 / 42 67 / 34 59 / 28 47 / 20 38 / 14 29 - 1
22 89 / 262 57 / 134 47 / 101 40 / 78 34 / 61 29 / 49 26 / 40 23 / 33 - - 20 - 3
Form Deck

20 117 / 322 75 / 165 62 / 124 53 / 95 45 / 75 39 / 60 34 / 49 30 / 40 23 / 28 - 24 - 2


Double
18 168 / 428 108 / 219 90 / 165 75 / 127 64 / 100 55 / 80 48 / 65 42 / 53 34 / 38 27 / 27 30 - 0
16 219 / 539 141 / 276 116 / 207 98 / 160 83 / 126 72 / 101 63 / 82 55 / 67 44 / 47 35 / 35 34 - 9
22 105 / 205 71 / 105 59 / 79 50 / 61 42 / 48 37 / 38 32 / 31 - - - 20 - 6
20 146 / 252 94 / 129 78 / 97 65 / 75 56 / 59 48 / 47 42 / 38 - - - 24 - 6
Triple
18 210 / 335 135 / 171 112 / 129 94 / 99 80 / 78 69 / 62 60 / 51 - - - 30 - 5
Typical Fastener Layouts

16 272 / 422 175 / 216 145 / 162 122 / 125 104 / 98 90 / 79 78 / 64 - - - 35 - 3


Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
3-3 3-3 3-3 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
22 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20 40 4-2 4-2 4-2 than the maximum design or construction spans shown in table above
18 40 5-8 5-8 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

16 40 6-2 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
26 www.newmill.com/digital-tools
Curve-Dek®

Table of Contents
Roof Decks - Type ND
PROPERTIES

Gage
Thickness2 5 ˝ Cover
8
Weight 2 85 ˝
(in) (in) (psf)
20 0.0358 2.47 3˝ 3˝
24
18 0.0474 3.27
8˝ 8˝
187 ˝ 187 ˝

Roof Deck
24˝ Coverage 24˝ Coverage
• Radii as low as 100'-0"
• Galvanized sheet steel with continuous lengths up to 36'-0".

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω

Composite Deck
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20 40 0.928 1.043 0.868 1.040 0.477 0.563 11413 13484 3585 668 1325
18 40 1.297 1.386 1.253 1.386 0.683 0.752 16356 18023 5620 1131 2232
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.

Deep-Dek®
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 -0 20 - 0 (ctr / ctr)
20 119 / 119 76 / 61 63 / 46 53 / 35 45 / 28 39 / 22 34 / 18 30 / 15 23 / 10 - 17 - 2
Single
18 170 / 166 109 / 85 90 / 64 76 / 49 65 / 39 56 / 31 48 / 25 43 / 21 34 / 15 27 / 11 22 - 11
20 133 / 322 89 / 165 74 / 124 62 / 95 53 / 75 46 / 60 40 / 49 35 / 40 28 / 28 - 20 - 10
Double

Form Deck
18 185 / 428 119 / 219 99 / 165 83 / 127 71 / 100 61 / 80 53 / 65 47 / 53 37 / 38 30 / 27 27 - 8
20 151 / 252 110 / 129 92 / 97 77 / 75 66 / 59 57 / 47 50 / 38 - - - 21 - 2
Triple
18 230 / 335 148 / 171 123 / 129 103 / 99 88 / 78 76 / 62 66 / 51 - - - 28 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of

Typical Fastener Layouts


deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.

MAXIMUM CANTILEVER SPANS


General Information

Fy Back-Span Condition Notes:


Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
4 - 10 4 - 10 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
18 40 5 - 10 5 - 11 4-4 than the maximum design or construction spans shown in table above
● Bearing width at perimeter support assumed to be 3'' minimum
● Design total uniform load of 45 psf in conjuncon with a 100 lb. concentrated load.
Code of Standard Practice

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 27
Curve-Dek® Acoustical
Table of Contents

Roof Decks - Type NDA


PROPERTIES
Thickness Cover Weight 2 85 ˝ 2 85 ˝
Gage
(in) (in) (psf)
20 0.0358 2.21 3˝ 3˝
24
18 0.0474 2.92
8˝ 8˝
187 ˝ 187 ˝
Roof Deck

24˝ Coverage 24˝ Coverage


• Radii as low as 100'-0"
• Galvanized sheet steel with continuous lengths up to 36'-0".

ASD SECTION PROPERTIES DESIGN STRENGTHS


ID 1 Span ID 2+ Span Ip In Sp Sn
Composite Deck

Fy Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω


Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20 40 0.867 0.978 0.809 0.975 0.437 0.522 10456 12503 2525 399 807
18 40 1.217 1.301 1.175 1.301 0.631 0.699 15107 16738 3952 752 1507
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Versa-Dek®

Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
8 -0 10 - 0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 - 0 20 - 0 (ctr / ctr)
20 100 / 111 70 / 57 58 / 43 48 / 33 41 / 26 36 / 21 31 / 17 27 / 14 - - 16 - 0
Single
18 157 / 156 101 / 80 83 / 60 70 / 46 60 / 36 51 / 29 45 / 24 39 / 19 31 / 14 25 / 10 21 - 8
20 81 / 302 65 / 155 59 / 116 54 / 89 49 / 70 42 / 56 37 / 46 32 / 38 26 / 26 - 19 - 5
Double
Form Deck

18 151 / 402 110 / 206 91 / 154 77 / 119 65 / 94 56 / 75 49 / 61 43 / 50 34 / 35 28 / 26 26 - 3


20 92 / 236 73 / 121 67 / 91 61 / 70 56 / 55 52 / 44 46 / 36 - - - 19 - 9
Triple
18 171 / 314 136 / 161 113 / 121 95 / 93 81 / 73 70 / 59 61 / 48 - - - 26 - 7
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
Typical Fastener Layouts

deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.

MAXIMUM CANTILEVER SPANS


General Information

Fy Back-Span Condition Notes:


Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
4-6 4-6 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
18 40 5-9 5 - 10 4-4 than the maximum design or construction spans shown in table above
● Bearing width at perimeter support assumed to be 3'' minimum
● Design total uniform load of 45 psf in conjuncon with a 100 lb. concentrated load.
Code of Standard Practice

Discover the easiest way to specify Steel Roof and Floor Deck:
28 www.newmill.com/digital-tools
Curve-Dek® Cellular

Table of Contents
Roof Decks - Type NDC Cellular
PROPERTIES
Gage Thickness Cover Weight
2 85 ˝ 187 ˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 3.96

20/18 0.0358/0.0474 4.49
24.5
18/20 0.0474/0.0358 4.70 8˝

Roof Deck
18/18 0.0474/0.0474 5.24 1
24 2 ˝ Coverage

• Radii as low as 100'-0"


• Galvanized sheet steel with continuous lengths up to 36'-0".

ASD SECTION PROPERTIES DESIGN STRENGTHS


ID 1 Span ID 2+ Span Ip In Sp Sn

Composite Deck
Fy Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 40 1.619 1.788 1.451 1.703 0.554 1.005 13269 24062 3512 668 1325
20/18 40 1.760 2.037 1.569 1.984 0.552 1.043 13220 24990 3512 668 1325
18/20 40 2.106 2.154 1.972 2.044 0.832 1.281 19926 30686 5505 1131 2232
18/18 40 2.300 2.447 2.148 2.368 0.853 1.350 20432 32325 5505 1131 2232
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.

Deep-Dek®
Gage Center to Center Span (ft - in)
Condition Span
8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 -0 20 - 0 (ctr / ctr)
20/20 138 / 207 88 / 106 73 / 80 61 / 61 52 / 48 45 / 39 39 / 31 35 / 26 27 / 18 - 18 - 8
20/18 138 / 225 88 / 115 73 / 87 61 / 67 52 / 53 45 / 42 39 / 34 34 / 28 27 / 20 - 18 - 3
Single
18/20 208 / 270 133 / 138 110 / 104 92 / 80 79 / 63 68 / 50 59 / 41 52 / 34 41 / 24 33 / 17 25 - 6
18/18 213 / 295 136 / 151 113 / 113 95 / 87 81 / 69 69 / 55 61 / 45 53 / 37 42 / 26 34 / 19 25 - 6

Form Deck
20/20 133 / 552 106 / 283 96 / 212 88 / 164 82 / 129 76 / 103 70 / 84 61 / 69 49 / 48 39 / 35 22 - 6
20/18 133 / 629 106 / 322 96 / 242 88 / 186 82 / 147 76 / 117 70 / 95 61 / 79 48 / 55 39 / 40 22 - 0
Double
18/20 223 / 665 179 / 340 162 / 256 139 / 197 119 / 155 103 / 124 90 / 101 79 / 83 63 / 58 51 / 43 30 - 6
18/18 223 / 756 179 / 387 162 / 291 147 / 224 125 / 176 108 / 141 95 / 115 83 / 94 66 / 66 53 / 48 30 - 5
20/20 151 / 432 120 / 221 110 / 166 96 / 128 82 / 101 71 / 81 61 / 66 - - - 22 - 9
20/18 151 / 492 120 / 252 110 / 189 96 / 146 81 / 115 70 / 92 61 / 75 - - - 22 - 3
Triple

Typical Fastener Layouts


18/20 254 / 520 203 / 266 172 / 200 144 / 154 123 / 121 106 / 97 92 / 79 - - - 30 - 11
18/18 254 / 591 203 / 303 176 / 227 148 / 175 126 / 138 109 / 110 95 / 90 - - - 30 - 10
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded. General Information
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
5 - 11 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20/20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20/18 40 6 - 11 5 - 11 4-4 than the maximum design or construction spans shown in table above
18/20 40 6-5 5 - 11 4-4
Code of Standard Practice

● Bearing width at perimeter support assumed to be 3'' minimum


18/18 40 6-7 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb. concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 29
Curve-Dek® Cellular Acoustical
Table of Contents

Roof Decks - Type NDCA Cellular


PROPERTIES
Gage Thickness Cover Weight
2 85 ˝ 187 ˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 3.80

20/18 0.0358/0.0474 4.28
24.5
18/20 0.0474/0.0358 4.54 8˝
Roof Deck

18/18 0.0474/0.0474 5.03 1


24 2 ˝ Coverage

• Radii as low as 100'-0"


• Galvanized sheet steel with continuous lengths up to 36'-0".

ASD SECTION PROPERTIES DESIGN STRENGTHS


Composite Deck

Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω


Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 40 1.567 1.764 1.407 1.702 0.556 1.005 13319 24066 3512 668 1325
20/18 40 1.706 2.005 1.524 1.972 0.553 1.043 13249 24975 3512 668 1325
18/20 40 2.036 2.126 1.909 2.043 0.824 1.283 19736 30733 5505 1131 2232
18/18 40 2.225 2.410 2.080 2.357 0.845 1.349 20246 32312 5505 1131 2232
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Versa-Dek®

Gage Center to Center Span (ft - in)


Condition Span
8 -0 10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 -0 20 - 0 (ctr / ctr)
20/20 139 / 201 89 / 103 73 / 77 62 / 59 53 / 47 45 / 37 39 / 30 35 / 25 27 / 18 - 18 - 9
20/18 138 / 218 88 / 112 73 / 84 61 / 65 52 / 51 45 / 41 39 / 33 35 / 27 27 / 19 - 18 - 5
Single
18/20 206 / 261 132 / 133 109 / 100 91 / 77 78 / 61 67 / 49 58 / 40 51 / 33 41 / 23 33 / 17 25 - 6
18/18 211 / 285 135 / 146 112 / 110 94 / 84 80 / 66 69 / 53 60 / 43 53 / 36 42 / 25 34 / 18 25 - 6
Form Deck

20/20 133 / 545 106 / 279 96 / 209 88 / 161 82 / 127 76 / 102 70 / 83 62 / 68 49 / 48 39 / 35 22 - 8


20/18 133 / 619 106 / 317 96 / 238 88 / 183 82 / 144 76 / 115 70 / 94 61 / 77 48 / 54 39 / 40 22 - 2
Double
18/20 223 / 656 179 / 336 162 / 252 140 / 194 119 / 153 103 / 122 90 / 100 79 / 82 63 / 58 51 / 42 30 - 6
18/18 223 / 744 179 / 381 162 / 286 147 / 220 125 / 173 108 / 139 94 / 113 83 / 93 66 / 65 53 / 48 30 - 6
20/20 151 / 426 120 / 218 110 / 164 96 / 126 82 / 99 71 / 80 62 / 65 - - - 23 - 0
20/18 151 / 484 120 / 248 110 / 186 96 / 144 82 / 113 70 / 90 61 / 73 - - - 22 - 6
Triple
Typical Fastener Layouts

18/20 254 / 514 203 / 263 170 / 198 143 / 152 122 / 120 105 / 96 91 / 78 - - - 30 - 11
18/18 254 / 582 203 / 298 174 / 224 146 / 173 125 / 136 108 / 109 94 / 88 - - - 30 - 10
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
General Information

6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
5 - 11 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20/20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20/18 40 6-1 5 - 11 4-4 than the maximum design or construction spans shown in table above
18/20 40 6-4 5 - 11 4-4
Code of Standard Practice

● Bearing width at perimeter support assumed to be 3'' minimum


18/18 40 6-6 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb. concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
30 www.newmill.com/digital-tools
Versa-Dek® 2.0 S ES

Table of Contents
Roof Decks - Type 2.0VSES
PROPERTIES

Gage
Thickness Cover Weight 483 ˝ 6˝
(in) (in) (psf)
20 0.0358 2.70

18 0.0474 24 3.56
5
16 0.0598 4.49 8˝

Roof Deck
24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)

Composite Deck
20 40 0.511 0.511 0.511 0.437 0.390 0.346 9330 8292 3519 933 1827
18 40 0.674 0.674 0.674 0.627 0.514 0.475 12319 11374 4617 1561 3047
16 40 0.848 0.848 0.848 0.828 0.646 0.615 15481 14725 5769 2390 4654
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.

Deep-Dek®
Gage Center to Center Span (ft - in)
Condition Span
6 -0 6 -6 7 -0 7 -6 8 -0 9 -0 10 - 0 11 -0 12 -0 13 -0 (ctr / ctr)
20 173 / 155 147 / 122 127 / 98 111 / 79 97 / 65 77 / 46 62 / 33 51 / 25 43 / 19 37 / 15 14 - 2
Single 18 228 / 205 194 / 161 168 / 129 146 / 105 128 / 86 101 / 61 82 / 44 68 / 33 57 / 26 49 / 20 17 - 8
16 287 / 257 244 / 202 211 / 162 183 / 132 161 / 109 127 / 76 103 / 56 85 / 42 72 / 32 61 / 25 20 - 10
20 152 / 374 129 / 294 112 / 235 97 / 191 86 / 158 68 / 111 55 / 81 46 / 61 38 / 47 33 / 37 17 - 3

Form Deck
Double 18 208 / 494 177 / 388 153 / 311 134 / 253 118 / 208 93 / 146 75 / 107 62 / 80 52 / 62 45 / 49 21 - 5
16 269 / 621 229 / 488 198 / 391 173 / 318 152 / 262 120 / 184 98 / 134 81 / 101 68 / 78 58 / 61 25 - 1
20 188 / 293 161 / 230 139 / 184 121 / 150 107 / 123 85 / 87 69 / 63 57 / 47 48 / 37 41 / 29 17 - 5
Triple 18 258 / 386 220 / 304 191 / 243 166 / 198 146 / 163 116 / 114 94 / 83 78 / 63 65 / 48 56 / 38 21 - 8
16 333 / 486 285 / 382 246 / 306 215 / 249 189 / 205 150 / 144 122 / 105 101 / 79 85 / 61 72 / 48 25 - 5
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:

Typical Fastener Layouts


● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.

General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
3-1 3-1 3-1 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
18 40 4-1 3 - 11 3 - 11 than the maximum design or construction spans shown in table above
16 40 4-8 4-5 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
● Design total uniform load of 45 psf in conjuncon with a 100 lb.
Code of Standard Practice

concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 31
Versa-Dek® 2.0 S ES Acoustical
Table of Contents

Roof Decks - Type 2.0VSESA


PROPERTIES

Gage
Thickness Cover Weight 483 ˝ 6˝
(in) (in) (psf)
20 0.0358 2.51

18 0.0474 24 3.32
5
16 0.0598 4.18 8˝
Roof Deck

24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
Composite Deck

20 40 0.483 0.483 0.483 0.427 0.383 0.345 9178 8268 3519 933 1827
18 40 0.637 0.637 0.637 0.607 0.506 0.473 12118 11327 4617 1561 3047
16 40 0.802 0.802 0.802 0.794 0.636 0.612 15227 14668 5769 2390 4654
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span
Versa-Dek®

Constr.
Gage Center to Center Span (ft - in)
Condition Span
6 -0 6 -6 7 -0 7 -6 8 -0 9 -0 10 - 0 11 -0 12 -0 13 -0 (ctr / ctr)
20 170 / 147 145 / 115 125 / 92 109 / 75 96 / 62 76 / 43 61 / 32 51 / 24 42 / 18 36 / 14 14 - 0
Single 18 224 / 193 191 / 152 165 / 122 144 / 99 126 / 82 100 / 57 81 / 42 67 / 31 56 / 24 48 / 19 17 - 7
16 282 / 243 240 / 191 207 / 153 180 / 125 159 / 103 125 / 72 102 / 53 84 / 39 70 / 30 60 / 24 20 - 10
20 151 / 353 129 / 278 111 / 223 97 / 181 85 / 149 68 / 105 55 / 76 45 / 57 38 / 44 33 / 35 17 - 1
Form Deck

Double 18 207 / 467 177 / 367 152 / 294 133 / 239 117 / 197 93 / 138 75 / 101 62 / 76 52 / 58 45 / 46 21 - 3
16 267 / 587 228 / 461 197 / 369 172 / 300 151 / 247 120 / 174 97 / 127 80 / 95 68 / 73 58 / 58 25 - 0
20 188 / 277 160 / 218 139 / 174 121 / 142 107 / 117 84 / 82 68 / 60 57 / 45 48 / 35 41 / 27 17 - 4
Triple 18 257 / 365 220 / 287 190 / 230 166 / 187 146 / 154 115 / 108 94 / 79 78 / 59 65 / 46 56 / 36 21 - 7
16 332 / 459 284 / 361 245 / 289 214 / 235 189 / 194 149 / 136 121 / 99 100 / 75 84 / 57 72 / 45 25 - 4
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
Typical Fastener Layouts

● ANSI/SDI RD-2017 Standard for Steel Roof Deck


● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
3-1 3-1 3-0 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
18 40 4-1 3 - 10 3-9 than the maximum design or construction spans shown in table above
16 40 4-8 4-4 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
● Design total uniform load of 45 psf in conjuncon with a 100 lb.
Code of Standard Practice

concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
32 www.newmill.com/digital-tools
Versa-Dek® 2.0 LS ES

Table of Contents
Roof Decks - Type 2.0VLSES
PROPERTIES

Gage
Thickness Cover Weight 483 ˝ 6
(in) (in) (psf)
22 0.0295 2.25

20 0.0358 2.72
24 5
18 0.0474 3.60 8˝

Roof Deck
16 0.0598 4.53 24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.417 0.417 0.417 0.406 0.304 0.309 7282 7401 2914 653 1282

Composite Deck
20 40 0.506 0.506 0.505 0.506 0.386 0.379 9246 9074 3519 933 1827
18 40 0.667 0.667 0.667 0.667 0.510 0.507 12207 12135 4617 1561 3047
16 40 0.838 0.838 0.838 0.838 0.640 0.640 15339 15339 5769 2390 4654
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
6 -0 6 -6 7 -0 7 -6 8 -0 9 -0 10 -0 11 -0 12 -0 13 - 0 (ctr / ctr)
22 135 / 127 115 / 100 99 / 80 86 / 65 76 / 53 60 / 38 49 / 27 40 / 21 34 / 16 - 11 - 4
20 171 / 153 146 / 121 126 / 97 110 / 79 96 / 65 76 / 45 62 / 33 51 / 25 43 / 19 36 / 15 14 - 0
Single
18 226 / 202 193 / 159 166 / 127 145 / 104 127 / 85 100 / 60 81 / 44 67 / 33 57 / 25 48 / 20 17 - 6
16 284 / 254 242 / 200 209 / 160 182 / 130 160 / 107 126 / 75 102 / 55 85 / 41 71 / 32 61 / 25 20 - 8
22 135 / 305 115 / 240 100 / 192 87 / 156 76 / 129 60 / 90 49 / 66 41 / 50 34 / 38 29 / 30 13 - 11

Form Deck
20 165 / 370 141 / 291 122 / 233 106 / 190 94 / 156 74 / 110 60 / 80 50 / 60 42 / 46 36 / 36 17 - 1
Double
18 221 / 488 189 / 384 163 / 307 142 / 250 125 / 206 99 / 145 80 / 105 67 / 79 56 / 61 48 / 48 21 - 2
16 279 / 613 239 / 483 206 / 386 180 / 314 158 / 259 125 / 182 102 / 133 84 / 100 71 / 77 60 / 60 24 - 10
22 168 / 239 143 / 188 124 / 150 108 / 122 95 / 101 75 / 71 61 / 52 51 / 39 43 / 30 36 / 23 14 - 1
20 205 / 290 176 / 228 152 / 182 132 / 148 117 / 122 92 / 86 75 / 63 62 / 47 52 / 36 45 / 28 17 - 4
Triple
18 274 / 382 235 / 300 203 / 241 177 / 196 156 / 161 124 / 113 100 / 82 83 / 62 70 / 48 60 / 38 21 - 6

Typical Fastener Layouts


16 347 / 480 296 / 378 256 / 302 224 / 246 197 / 203 156 / 142 127 / 104 105 / 78 88 / 60 75 / 47 25 - 2
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans. General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
2 - 10 2 - 10 2 - 10 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
22 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20 40 3-4 3-3 3-3 than the maximum design or construction spans shown in table above
18 40 4-4 4-0 3 - 11 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

16 40 4-8 4-5 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 33

Versa-Dek® 2.0 LS ES Acoustical


Table of Contents

5

24˝ Coverage
Roof Decks - Type 2.0VLSESA
PROPERTIES
Thickness Cover Weight 483 ˝
Gage 6
(in) (in) (psf)
22 0.0295 2.08

20 0.0358 2.53
24 5
18 0.0474 3.34 8˝
Roof Deck

16 0.0598 4.21 24˝ Coverage


ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.393 0.393 0.393 0.393 0.298 0.308 7146 7373 2914 653 1282
Composite Deck

20 40 0.476 0.476 0.476 0.476 0.379 0.377 9075 9027 3519 933 1827
18 40 0.628 0.628 0.628 0.628 0.500 0.500 11981 11981 4617 1561 3047
16 40 0.789 0.789 0.789 0.789 0.629 0.629 15054 15054 5769 2390 4654
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

6 -0 6 -6 7 -0 7 -6 8 -0 9 -0 10 - 0 11 -0 12 -0 13 - 0 (ctr / ctr)
22 132 / 119 113 / 94 97 / 75 85 / 61 74 / 50 59 / 35 48 / 26 39 / 19 33 / 15 - 11 - 2
20 168 / 144 143 / 114 123 / 91 108 / 74 95 / 61 75 / 43 60 / 31 50 / 23 42 / 18 36 / 14 13 - 10
Single
18 222 / 191 189 / 150 163 / 120 142 / 98 125 / 80 99 / 56 80 / 41 66 / 31 55 / 24 47 / 19 17 - 5
16 279 / 240 238 / 188 205 / 151 178 / 123 157 / 101 124 / 71 100 / 52 83 / 39 70 / 30 59 / 24 20 - 7
22 134 / 287 115 / 226 99 / 181 87 / 147 76 / 121 60 / 85 49 / 62 40 / 47 34 / 36 29 / 28 13 - 8
Form Deck

20 165 / 348 141 / 274 121 / 219 106 / 178 93 / 147 74 / 103 60 / 75 50 / 56 42 / 44 35 / 34 16 - 11
Double
18 218 / 459 186 / 361 161 / 289 141 / 235 124 / 194 98 / 136 79 / 99 66 / 75 55 / 57 47 / 45 21 - 1
16 274 / 578 234 / 454 202 / 364 177 / 296 155 / 244 123 / 171 100 / 125 83 / 94 69 / 72 59 / 57 24 - 9
22 167 / 225 143 / 177 123 / 142 108 / 115 95 / 95 75 / 67 61 / 49 50 / 36 42 / 28 36 / 22 13 - 11
20 204 / 272 175 / 214 151 / 172 132 / 139 116 / 115 92 / 81 75 / 59 62 / 44 52 / 34 44 / 27 17 - 1
Triple
18 271 / 360 232 / 283 200 / 226 175 / 184 154 / 152 122 / 107 99 / 78 82 / 58 69 / 45 59 / 35 21 - 4
Typical Fastener Layouts

16 341 / 452 291 / 356 252 / 285 220 / 231 193 / 191 153 / 134 124 / 98 103 / 73 87 / 57 74 / 44 25 - 1
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
2-9 2-9 2-9 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
22 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20 40 3-4 3-2 3-1 than the maximum design or construction spans shown in table above
18 40 4-4 3 - 10 3-9 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

16 40 4-8 4-4 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
34 www.newmill.com/digital-tools
Versa-Dek® 3.5 LS

Table of Contents
Roof Decks - Type 3.5VLS
PROPERTIES
Thickness Cover Weight 8˝ 443 ˝
Gage
(in) (in) (psf)
20 0.0358 3.33
3 21 ˝
19 0.0418 3.88
24
18 0.0474 4.40 3

Roof Deck

16 0.0598 5.54
24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20 40 1.959 1.959 1.917 1.766 0.775 0.910 18554 21806 3383 622 1313

Composite Deck
19 40 2.324 2.324 2.296 2.129 0.946 1.072 22653 25665 4613 833 1744
18 40 2.664 2.664 2.648 2.475 1.113 1.226 26662 29365 5931 1055 2194
16 40 3.394 3.394 3.394 3.262 1.504 1.573 36031 37687 8289 1631 3355
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 -0 20 -0 22 -0 (ctr / ctr)
20 124 / 128 102 / 96 86 / 74 73 / 58 63 / 47 55 / 38 48 / 31 38 / 22 31 / 16 26 / 12 25 - 6
19 151 / 152 125 / 114 105 / 88 89 / 69 77 / 56 67 / 45 59 / 37 47 / 26 38 / 19 31 / 14 29 - 4
Single
18 178 / 175 147 / 131 123 / 101 105 / 79 91 / 64 79 / 52 69 / 43 55 / 30 44 / 22 37 / 16 32 - 8
16 240 / 223 199 / 167 167 / 129 142 / 101 123 / 81 107 / 66 94 / 54 74 / 38 60 / 28 50 / 21 38 - 11
20 105 / 310 96 / 233 88 / 179 81 / 141 73 / 113 64 / 92 56 / 76 44 / 53 36 / 39 - 30 - 8

Form Deck
19 140 / 367 127 / 276 116 / 213 100 / 167 86 / 134 75 / 109 66 / 90 52 / 63 42 / 46 - 35 - 2
Double
18 176 / 421 159 / 316 134 / 244 114 / 192 99 / 153 86 / 125 76 / 103 60 / 72 49 / 53 - 38 - 11
16 247 / 537 205 / 403 172 / 311 147 / 244 127 / 196 111 / 159 97 / 131 77 / 92 63 / 67 - 40 - 0
20 119 / 242 109 / 182 100 / 140 92 / 110 85 / 88 79 / 72 - - - - 31 - 1
19 159 / 288 144 / 216 132 / 166 122 / 131 107 / 105 93 / 85 - - - - 35 - 7
Triple
18 199 / 330 181 / 248 166 / 191 142 / 150 123 / 120 107 / 98 - - - - 39 - 5

Typical Fastener Layouts


16 305 / 420 254 / 315 214 / 243 183 / 191 158 / 153 138 / 124 - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans. General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
6-5 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
19 40 6-8 5 - 11 4-4 than the maximum design or construction spans shown in table above
18 40 6 - 11 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

16 40 8-9 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 35
Versa-Dek® 3.5 LS Acoustical
Table of Contents

Roof Decks - Type 3.5VLSA


PROPERTIES
Thickness Cover Weight 4 43 ˝
Gage 8˝
(in) (in) (psf)
20 0.0358 3.07
19 0.0418 3.59 3 21 ˝
24
18 0.0474 4.06
Roof Deck

3
16 0.0598 5.12 4˝
24˝ Coverage ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20 40 1.803 1.803 1.766 1.742 0.754 0.909 18063 21778 3383 622 1313
Composite Deck

19 40 2.139 2.139 2.113 2.089 0.921 1.072 22061 25673 4613 833 1744
18 40 2.450 2.450 2.436 2.418 1.084 1.224 25970 29327 5931 1055 2194
16 40 3.122 3.123 3.122 3.123 1.466 1.564 35113 37461 8289 1631 3355
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 -0 20 -0 22 -0 (ctr / ctr)
20 120 / 118 100 / 89 84 / 68 71 / 54 61 / 43 54 / 35 47 / 29 37 / 20 30 / 15 25 / 11 25 - 2
19 147 / 140 122 / 105 102 / 81 87 / 64 75 / 51 65 / 42 57 / 34 45 / 24 37 / 18 30 / 13 29 - 1
Single
18 173 / 161 143 / 121 120 / 93 102 / 73 88 / 59 77 / 48 68 / 39 53 / 28 43 / 20 36 / 15 32 - 6
16 234 / 205 193 / 154 163 / 118 139 / 93 119 / 75 104 / 61 91 / 50 72 / 35 59 / 26 48 / 19 39 - 0
20 105 / 285 96 / 214 88 / 165 81 / 130 73 / 104 64 / 84 56 / 70 44 / 49 36 / 36 - 30 - 4
Form Deck

19 140 / 338 127 / 254 116 / 196 100 / 154 86 / 123 75 / 100 66 / 83 52 / 58 43 / 42 - 34 - 11
Double
18 176 / 387 159 / 291 134 / 224 114 / 176 99 / 141 86 / 115 76 / 95 60 / 66 49 / 48 - 38 - 10
16 245 / 494 203 / 371 171 / 286 146 / 225 126 / 180 110 / 146 97 / 121 77 / 85 62 / 62 - 40 - 0
20 119 / 223 109 / 168 100 / 129 92 / 102 85 / 81 79 / 66 - - - - 30 - 9
19 159 / 265 144 / 199 132 / 153 122 / 120 107 / 96 93 / 78 - - - - 35 - 4
Triple
18 199 / 303 181 / 228 166 / 175 142 / 138 123 / 110 107 / 90 - - - - 39 - 4
Typical Fastener Layouts

16 304 / 386 253 / 290 213 / 224 182 / 176 157 / 141 137 / 114 - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 1 1/2'' for end bearing and 3'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
6-4 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
19 40 6-7 5 - 11 4-4 than the maximum design or construction spans shown in table above
18 40 6 - 10 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 3'' minimum
Code of Standard Practice

16 40 7-3 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
36 www.newmill.com/digital-tools
Super Versa-Dek® 6.5 LS

Table of Contents
Roof Decks - Type 6.5SVLS
PROPERTIES 8˝
2 85 ˝
Thickness Cover Weight
Gage
(in) (in) (psf)
20/20 0.0358/0.0358 5.81
6 21 ˝
18/18 0.0474/0.0474 24 7.70
16/16 0.0598/0.0598 9.72

Roof Deck
3

24˝ Coverage

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)

Composite Deck
20/20 40 8.183 8.655 7.320 8.028 1.581 2.068 37876 49536 3383 681 1437
18/18 40 11.605 12.048 10.811 11.476 2.489 2.993 59619 71684 5931 1151 2390
16/16 40 15.239 15.887 14.486 15.458 3.564 4.138 85367 99113 8289 1771 3638
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 2" for end bearing and 4" for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.

Deep-Dek®
Gage Center to Center Span (ft - in)
Condition Span
15 -0 16 - 0 17 - 0 18 - 0 20 -0 22 -0 24 -0 26 -0 28 -0 30 -0 (ctr / ctr)
20/20 91 / 159 85 / 131 80 / 109 76 / 92 63 / 67 52 / 50 44 / 39 37 / 31 32 / 24 28 / 20 39 - 11
Single 18/18 153 / 225 144 / 186 135 / 155 123 / 130 99 / 95 82 / 71 69 / 55 59 / 43 51 / 35 44 / 28 40 - 0
16/16 236 / 296 221 / 244 197 / 203 176 / 171 142 / 125 118 / 94 99 / 72 84 / 57 73 / 46 63 / 37 40 - 0

Form Deck
Double

Contact New Millennium for multiple span information

Triple

Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:

Typical Fastener Layouts


● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 2'' for end bearing and 4'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.

General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
6 - 11 Contact New Millennium ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20/20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
18/18 40 8-5 for multiple span
than the maximum design or construction spans shown in table above
16/16 40 9-9 information
● Bearing width at perimeter support assumed to be 4" minimum
● Design total uniform load of 45 psf in conjuncon with a 100 lb. concentrated load.
Code of Standard Practice

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 37
Super Versa-Dek® 6.5 LS Acoustical
Table of Contents

Roof Decks - Type 6.5SVLSA


PROPERTIES 8˝
2 85 ˝
Thickness Cover Weight
Gage
(in) (in) (psf)
20/20 0.0358/0.0358 5.54
6 21 ˝
18/18 0.0474/0.0474 24 7.35
16/16 0.0598/0.0598 9.28
Roof Deck

3

24˝ Coverage

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
Composite Deck

20/20 40 7.618 8.518 6.856 8.206 1.552 2.105 37167 50423 3383 681 1437
18/18 40 10.787 11.785 10.090 11.586 2.435 3.056 58319 73206 5931 1151 2390
16/16 40 14.164 15.238 13.510 15.120 3.478 4.171 83315 99907 8289 1771 3638
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 2" for end bearing and 4" for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Versa-Dek®

Gage Center to Center Span (ft - in)


Condition Span
15 -0 16 - 0 17 - 0 18 - 0 20 -0 22 -0 24 -0 26 -0 28 -0 30 -0 (ctr / ctr)
20/20 91 / 148 85 / 122 80 / 102 76 / 86 62 / 62 51 / 47 43 / 36 37 / 28 32 / 23 28 / 18 39 - 10
Single 18/18 153 / 210 144 / 173 135 / 144 120 / 121 97 / 88 80 / 66 67 / 51 58 / 40 50 / 32 43 / 26 40 - 0
16/16 236 / 275 217 / 227 192 / 189 171 / 159 139 / 116 115 / 87 96 / 67 82 / 53 71 / 42 62 / 34 40 - 0
Form Deck

Double

Contact New Millennium for multiple span information

Triple

Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
Typical Fastener Layouts

● ANSI/SDI RD-2017 Standard for Steel Roof Deck


● Minimum bearing lengths of 2'' for end bearing and 4'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
6 - 11 Contact New Millennium ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20/20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
18/18 40 8-5 for multiple span
than the maximum design or construction spans shown in table above
16/16 40 9-9 information
● Bearing width at perimeter support assumed to be 4" minimum
● Design total uniform load of 45 psf in conjuncon with a 100 lb. concentrated load.
Code of Standard Practice

Discover the easiest way to specify Steel Roof and Floor Deck:
38 www.newmill.com/digital-tools
Deep-Dek® 4.5

Table of Contents
Roof Decks - Type 4.5D
PROPERTIES
Thickness Cover Weight 7 87 ˝
Gage
(in) (in) (psf)
20 0.0358 3.09
18 0.0474 4.09 4 85˝
12
16 0.0598 5.16

Roof Deck
14 0.0747 6.44 12˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20 40 2.735 2.978 2.613 2.978 0.984 1.207 23563 28920 1871 588 1164

Composite Deck
18 40 3.832 3.939 3.778 3.939 1.491 1.596 35724 38237 4224 990 1925
16 40 4.963 4.963 4.963 4.963 1.972 2.011 47234 48168 6723 1518 2917
14 40 6.191 6.191 6.191 6.191 2.507 2.507 60060 60060 9675 2279 4341
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 - 0 20 - 0 22 -0 (ctr / ctr)
20 118 / 179 107 / 135 98 / 104 90 / 82 80 / 65 70 / 53 61 / 44 48 / 31 39 / 22 32 / 17 31 - 6
18 198 / 251 180 / 189 165 / 145 141 / 114 122 / 92 106 / 74 93 / 61 74 / 43 60 / 31 49 / 24 40 - 0
Single
16 304 / 325 260 / 244 219 / 188 186 / 148 161 / 119 140 / 96 123 / 79 97 / 56 79 / 41 65 / 31 40 - 0
14 400 / 406 331 / 305 278 / 235 237 / 185 204 / 148 178 / 120 156 / 99 124 / 70 100 / 51 83 / 38 40 - 0
20 93 / 471 85 / 354 78 / 272 72 / 214 67 / 172 62 / 139 58 / 115 52 / 81 46 / 59 - 37 - 10

Form Deck
18 154 / 623 140 / 468 128 / 360 118 / 283 110 / 227 103 / 184 96 / 152 77 / 107 63 / 78 - 40 - 0
Double
16 233 / 785 212 / 589 194 / 454 179 / 357 160 / 286 140 / 232 123 / 192 98 / 135 79 / 98 - 40 - 0
14 347 / 979 316 / 735 272 / 566 232 / 445 201 / 357 175 / 290 154 / 239 122 / 168 99 / 122 - 40 - 0
20 106 / 368 96 / 277 88 / 213 81 / 168 76 / 134 71 / 109 - - - - 38 - 4
18 175 / 487 159 / 366 146 / 282 135 / 222 125 / 178 117 / 144 - - - - 40 - 0
Triple
16 265 / 614 241 / 461 221 / 355 204 / 279 189 / 224 174 / 182 - - - - 40 - 0

Typical Fastener Layouts


14 395 / 766 359 / 575 329 / 443 288 / 349 249 / 279 218 / 227 - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans. General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
7-0 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
18 40 8 - 11 5 - 11 4-4 than the maximum design or construction spans shown in table above
16 40 9-3 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

14 40 9-7 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 39
Deep-Dek® 4.5 Acoustical
Table of Contents

Roof Decks - Type 4.5DA


PROPERTIES
Thickness Cover Weight 7 87 ˝
Gage
(in) (in) (psf)
20 0.0358 2.94
18 0.0474 3.88 4 85˝
12
16 0.0598 4.90
Roof Deck

14 0.0747 6.11 12˝ Coverage 12˝ Coverage


ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20 40 2.546 2.789 2.425 2.789 0.904 1.127 21641 26993 1274 588 845
Composite Deck

18 40 3.586 3.690 3.533 3.690 1.385 1.491 33170 35704 2874 990 1391
16 40 4.652 4.652 4.652 4.652 1.840 1.879 44064 44996 4568 1518 2099
14 40 5.806 5.806 5.806 5.806 2.344 2.344 56135 56135 6564 2279 3113
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

10 -0 11 -0 12 -0 13 -0 14 -0 15 -0 16 -0 18 - 0 20 -0 22 -0 (ctr / ctr)
20 118 / 167 107 / 125 98 / 97 85 / 76 74 / 61 64 / 49 56 / 41 45 / 29 36 / 21 30 / 16 29 - 7
18 198 / 235 180 / 177 154 / 136 131 / 107 113 / 86 98 / 70 86 / 57 68 / 40 55 / 29 46 / 22 39 - 10
Single
16 294 / 305 243 / 229 204 / 176 174 / 139 150 / 111 131 / 90 115 / 74 91 / 52 73 / 38 61 / 29 40 - 0
14 374 / 381 309 / 286 260 / 220 221 / 173 191 / 139 166 / 113 146 / 93 116 / 65 94 / 48 77 / 36 40 - 0
20 68 / 441 61 / 331 56 / 255 52 / 201 48 / 161 45 / 131 42 / 108 38 / 76 34 / 55 - 35 - 7
Form Deck

18 111 / 583 101 / 438 93 / 338 86 / 265 79 / 213 74 / 173 70 / 142 62 / 100 56 / 73 - 40 - 0
Double
16 168 / 735 153 / 552 140 / 426 129 / 335 120 / 268 112 / 218 105 / 180 90 / 126 73 / 92 - 40 - 0
14 249 / 918 226 / 690 208 / 531 192 / 418 178 / 334 162 / 272 143 / 224 113 / 157 92 / 115 - 40 - 0
20 77 / 345 70 / 259 64 / 200 59 / 157 55 / 126 51 / 102 - - - - 36 - 1
18 126 / 456 115 / 343 105 / 264 97 / 208 90 / 166 84 / 135 - - - - 40 - 0
Triple
16 191 / 575 173 / 432 159 / 333 147 / 262 136 / 210 127 / 171 - - - - 40 - 0
Typical Fastener Layouts

14 283 / 718 257 / 540 236 / 416 218 / 327 202 / 262 189 / 213 - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
4-7 5-6 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
18 40 8 - 10 5 - 11 4-4 than the maximum design or construction spans shown in table above
16 40 9-2 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

14 40 9-6 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
40 www.newmill.com/digital-tools
Deep-Dek® 6.0

Table of Contents
Roof Decks - Type 6.0D
PROPERTIES
Thickness Cover Weight 7 87 ˝
Gage
(in) (in) (psf)
20 0.0358 3.44
18 0.0474 4.55 6 81˝
12
16 0.0598 5.74

Roof Deck
14 0.0747 7.16
12˝ Coverage ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20 40 5.304 5.668 5.083 5.629 1.367 1.711 32738 40994 1391 552 1156

Composite Deck
18 40 7.395 7.601 7.292 7.601 2.172 2.358 52033 56485 3235 940 1913
16 40 9.579 9.579 9.579 9.579 2.915 2.971 69827 71160 6510 1452 2900
14 40 11.950 11.950 11.950 11.950 3.705 3.705 88739 88739 10491 2193 4319
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
14 -0 15 -0 16 -0 17 -0 18 -0 19 -0 20 -0 22 - 0 24 -0 26 -0 (ctr / ctr)
20 79 / 127 74 / 103 69 / 85 65 / 71 61 / 60 58 / 51 55 / 43 45 / 33 38 / 25 32 / 20 40 - 0
18 134 / 177 125 / 144 118 / 118 111 / 99 104 / 83 96 / 71 87 / 61 72 / 46 60 / 35 51 / 28 40 - 0
Single
16 207 / 229 194 / 186 181 / 153 161 / 128 144 / 108 129 / 92 116 / 78 96 / 59 81 / 45 69 / 36 40 - 0
14 302 / 285 263 / 232 231 / 191 205 / 159 183 / 134 164 / 114 148 / 98 122 / 74 103 / 57 88 / 45 40 - 0
20 66 / 327 62 / 265 58 / 219 54 / 182 51 / 154 49 / 131 46 / 112 - - - 40 - 0

Form Deck
18 109 / 438 102 / 356 96 / 293 90 / 245 85 / 206 81 / 175 77 / 150 - - - 40 - 0
Double
16 166 / 552 155 / 449 145 / 370 136 / 308 129 / 260 122 / 221 116 / 189 - - - 40 - 0
14 247 / 688 230 / 560 216 / 461 200 / 384 179 / 324 161 / 275 146 / 236 - - - 40 - 0
20 75 / 256 70 / 208 - - - - - - - - 40 - 0
18 124 / 343 116 / 279 - - - - - - - - 40 - 0
Triple
16 188 / 432 176 / 351 - - - - - - - - 40 - 0

Typical Fastener Layouts


14 280 / 539 262 / 438 - - - - - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans. General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
8-4 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
18 40 9 - 11 5 - 11 4-4 than the maximum design or construction spans shown in table above
16 40 9 - 11 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

14 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 41
Deep-Dek® 6.0 Acoustical
Table of Contents

Roof Decks - Type 6.0DA


PROPERTIES
7 87 ˝
Thickness Cover Weight
Gage
(in) (in) (psf)
20 0.0358 3.22
18 0.0474 4.27 6 81˝
12
16 0.0598 5.38
Roof Deck

14 0.0747 6.71
12˝ Coverage 12˝ Coverage ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20 40 4.836 5.188 4.615 5.143 1.195 1.542 28613 36933 935 460 843
Composite Deck

18 40 6.781 6.983 6.680 6.983 1.972 2.159 47242 51720 2172 863 1387
16 40 8.804 8.804 8.804 8.804 2.665 2.721 63836 65185 4365 1438 2094
14 40 10.989 10.989 10.989 10.989 3.395 3.395 81328 81328 7026 2193 3107
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

14 -0 15 -0 16 -0 17 -0 18 - 0 19 - 0 20 - 0 22 - 0 24 -0 26 -0 (ctr / ctr)
20 66 / 116 61 / 94 57 / 77 54 / 65 51 / 54 48 / 46 46 / 40 39 / 30 33 / 23 28 / 18 36 - 9
18 123 / 162 115 / 132 108 / 109 102 / 90 96 / 76 87 / 65 79 / 56 65 / 42 55 / 32 47 / 25 40 - 0
Single
16 205 / 210 189 / 171 166 / 141 147 / 117 131 / 99 118 / 84 106 / 72 88 / 54 74 / 42 63 / 33 40 - 0
14 277 / 263 241 / 213 212 / 176 188 / 147 167 / 124 150 / 105 136 / 90 112 / 68 94 / 52 80 / 41 40 - 0
20 48 / 299 45 / 243 42 / 200 40 / 167 37 / 141 36 / 120 34 / 103 - - - 40 - 0
Form Deck

18 79 / 402 74 / 327 69 / 269 65 / 225 62 / 189 58 / 161 55 / 138 - - - 40 - 0


Double
16 120 / 507 112 / 412 105 / 340 99 / 283 93 / 239 88 / 203 84 / 174 - - - 40 - 0
14 178 / 633 166 / 515 155 / 424 146 / 354 138 / 298 131 / 253 124 / 217 - - - 40 - 0
20 55 / 234 51 / 190 - - - - - - - - 40 - 0
18 90 / 315 84 / 256 - - - - - - - - 40 - 0
Triple
16 136 / 397 127 / 323 - - - - - - - - 40 - 0
Typical Fastener Layouts

14 202 / 495 188 / 403 - - - - - - - - 40 - 0


Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
3-0 4-4 4-2 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
18 40 9 - 11 5 - 11 4-4 than the maximum design or construction spans shown in table above
16 40 9 - 11 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

14 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
42 www.newmill.com/digital-tools
Deep-Dek® 7.5

Table of Contents
Roof Decks - Type 7.5D
PROPERTIES
7 87 ˝
Thickness Cover Weight
Gage
(in) (in) (psf)
20 0.0358 3.79
18 0.0474 5.01 7 85 ˝
12
16 0.0598 6.32

Roof Deck
14 0.0747 7.89
12˝ Coverage ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20 40 8.828 9.285 8.446 9.131 1.712 2.162 41004 51795 1108 521 1148

Composite Deck
18 40 12.357 12.510 12.191 12.420 2.909 3.049 69680 73035 2575 896 1902
16 40 15.992 15.992 15.992 15.992 3.936 4.009 94274 96035 5178 1394 2886
14 40 19.952 19.952 19.952 19.952 5.000 5.000 119769 119769 10113 2117 4300
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
15 -0 16 -0 17 -0 18 -0 20 -0 22 - 0 24 - 0 26 -0 28 -0 30 -0 (ctr / ctr)
20 69 / 171 65 / 141 61 / 118 58 / 99 52 / 72 47 / 54 43 / 42 40 / 33 35 / 26 30 / 21 40 - 0
18 120 / 240 112 / 198 105 / 165 100 / 139 90 / 101 81 / 76 75 / 59 69 / 46 59 / 37 52 / 30 40 - 0
Single
16 186 / 311 174 / 256 164 / 213 155 / 180 139 / 131 127 / 98 109 / 76 93 / 60 80 / 48 70 / 39 40 - 0
14 282 / 388 265 / 319 249 / 266 235 / 224 200 / 163 165 / 123 139 / 95 118 / 74 102 / 60 89 / 48 40 - 0
20 61 / 435 57 / 358 54 / 299 51 / 252 46 / 183 - - - - - 40 - 0

Form Deck
18 101 / 586 95 / 483 90 / 402 85 / 339 76 / 247 - - - - - 40 - 0
Double
16 154 / 749 144 / 617 136 / 515 128 / 433 115 / 316 - - - - - 40 - 0
14 229 / 934 215 / 770 202 / 642 191 / 541 172 / 394 - - - - - 40 - 0
20 70 / 340 - - - - - - - - - 40 - 0
18 115 / 459 - - - - - - - - - 40 - 0
Triple
16 175 / 586 - - - - - - - - - 40 - 0

Typical Fastener Layouts


14 261 / 731 - - - - - - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans. General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
6 - 11 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
18 40 9 - 11 5 - 11 4-4 than the maximum design or construction spans shown in table above
16 40 9 - 11 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

14 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 43
Deep-Dek® 7.5 Acoustical
Table of Contents

Roof Decks - Type 7.5DA


PROPERTIES
7 87 ˝
Thickness Cover Weight
Gage
(in) (in) (psf)
20 0.0358 3.51
18 0.0474 4.65 7 21 ˝
12
16 0.0598 5.86
Roof Deck

14 0.0747 7.31
12˝ Coverage 12˝ Coverage ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20 40 7.829 8.301 7.417 8.126 1.448 1.897 34673 45448 738 422 841
Composite Deck

18 40 11.122 11.238 10.959 11.132 2.528 2.710 60556 64914 1714 807 1385
16 40 14.434 14.434 14.434 14.434 3.531 3.606 84580 86380 3445 1360 2091
14 40 18.017 18.017 18.017 18.017 4.500 4.500 107778 107778 6720 2117 3103
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

15 -0 16 -0 17 - 0 18 - 0 20 - 0 22 - 0 24 - 0 26 -0 28 -0 30 -0 (ctr / ctr)
20 56 / 152 53 / 125 50 / 104 47 / 88 42 / 64 38 / 48 35 / 37 32 / 29 29 / 23 26 / 19 40 - 0
18 108 / 216 101 / 178 95 / 148 90 / 125 81 / 91 73 / 68 67 / 53 60 / 41 51 / 33 45 / 27 40 - 0
Single
16 181 / 280 170 / 231 160 / 193 151 / 162 136 / 118 117 / 89 98 / 68 83 / 54 72 / 43 63 / 35 40 - 0
14 296 / 350 277 / 288 249 / 240 222 / 203 180 / 148 148 / 111 125 / 85 106 / 67 92 / 54 80 / 44 40 - 0
20 45 / 389 42 / 320 40 / 267 37 / 225 34 / 164 - - - - - 40 - 0
Form Deck

18 74 / 526 69 / 434 65 / 362 62 / 305 55 / 222 - - - - - 40 - 0


Double
16 112 / 676 105 / 557 98 / 464 93 / 391 84 / 285 - - - - - 40 - 0
14 165 / 844 155 / 695 146 / 580 138 / 488 124 / 356 - - - - - 40 - 0
20 51 / 304 - - - - - - - - - 40 - 0
18 84 / 412 - - - - - - - - - 40 - 0
Triple
16 127 / 529 - - - - - - - - - 40 - 0
Typical Fastener Layouts

14 188 / 660 - - - - - - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
1-4 3-0 2 - 10 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
18 40 9 - 11 5 - 11 4-4 than the maximum design or construction spans shown in table above
16 40 9 - 11 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

14 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
44 www.newmill.com/digital-tools
Deep-Dek® 4.5 Cellular

Table of Contents
Roof Decks - Type 4.5DC Cellular
PROPERTIES
Gage Thickness Cover Weight 7 87 ˝ 12˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 4.47
20/18 0.0358/0.0474 5.05 4 58 ˝
24
18/20 0.0474/0.0358 5.35

Roof Deck
18/18 0.0474/0.0474 5.92 24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 40 4.343 4.343 4.083 4.058 1.051 1.545 25166 37007 1871 588 1164

Composite Deck
20/18 40 4.634 4.839 4.322 4.628 1.054 1.603 25237 38391 1871 588 1164
18/20 40 5.750 5.750 5.638 4.995 1.728 2.008 41388 48085 4224 990 1925
18/18 40 6.210 6.210 6.085 5.626 1.727 2.076 41361 49716 4224 990 1925
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
11 -0 12 -0 13 -0 14 -0 15 -0 16 - 0 18 -0 20 -0 22 -0 24 -0 (ctr / ctr)
20/20 107 / 214 98 / 165 90 / 130 84 / 104 75 / 84 66 / 70 52 / 49 42 / 36 35 / 27 29 / 21 31 - 1
20/18 107 / 228 98 / 176 90 / 138 84 / 111 75 / 90 66 / 74 52 / 52 42 / 38 35 / 29 29 / 22 30 - 4
Single
18/20 180 / 283 165 / 218 152 / 172 141 / 137 123 / 112 108 / 92 85 / 65 69 / 47 57 / 35 48 / 27 40 - 0
18/18 180 / 306 165 / 236 152 / 185 141 / 148 123 / 121 108 / 99 85 / 70 69 / 51 57 / 38 48 / 29 40 - 0
20/20 85 / 516 78 / 397 72 / 312 67 / 250 62 / 203 58 / 168 52 / 118 47 / 86 - - 37 - 1

Form Deck
20/18 85 / 575 78 / 443 72 / 348 67 / 279 62 / 227 58 / 187 52 / 131 47 / 96 - - 36 - 2
Double
18/20 140 / 683 128 / 526 118 / 414 110 / 331 103 / 269 96 / 222 86 / 156 77 / 114 - - 40 - 0
18/18 140 / 737 128 / 568 118 / 447 110 / 358 103 / 291 96 / 240 86 / 168 77 / 123 - - 40 - 0
20/20 96 / 404 88 / 311 81 / 245 76 / 196 71 / 159 - - - - - 37 - 7
20/18 96 / 450 88 / 346 81 / 272 76 / 218 71 / 177 - - - - - 36 - 7
Triple
18/20 159 / 534 146 / 412 135 / 324 125 / 259 117 / 211 - - - - - 40 - 0

Typical Fastener Layouts


18/18 159 / 577 146 / 445 135 / 350 125 / 280 117 / 228 - - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans. General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
7 - 10 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20/20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20/18 40 9-1 5 - 11 4-4 than the maximum design or construction spans shown in table above
18/20 40 9 - 11 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

18/18 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 45
Deep-Dek® 4.5 Cellular
Table of Contents

Roof Decks - Type 4.5DC Cellular


PROPERTIES
Gage Thickness Cover Weight 7 87 ˝ 12˝
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 6.54
16/18 0.0598/0.0474 6.86 4 58 ˝
24
16/16 0.0598/0.0598 7.47
Roof Deck

14/16 0.0747/0.0598 8.59 24˝ Coverage


ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 40 6.629 6.629 6.491 6.277 1.726 2.141 41330 51271 4224 990 1925
Composite Deck

16/18 40 7.655 7.655 7.655 6.647 2.449 2.574 58649 61648 6723 1518 2917
16/16 40 8.180 8.180 8.180 7.378 2.493 2.651 59718 63494 6723 1518 2917
14/16 40 9.619 9.619 9.619 8.638 3.353 3.254 80304 77933 9675 2279 4341
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

13 -0 14 -0 15 -0 16 -0 17 -0 18 -0 20 -0 22 - 0 24 -0 26 -0 (ctr / ctr)
18/16 152 / 198 141 / 158 122 / 129 108 / 106 95 / 88 85 / 75 69 / 54 57 / 41 48 / 31 41 / 25 40 - 0
16/18 231 / 228 199 / 183 174 / 149 153 / 123 135 / 102 121 / 86 98 / 63 81 / 47 68 / 36 58 / 29 40 - 0
Single
16/16 233 / 244 203 / 195 177 / 159 156 / 131 138 / 109 123 / 92 100 / 67 82 / 50 69 / 39 59 / 31 40 - 0
14/16 317 / 287 273 / 230 238 / 187 209 / 154 185 / 128 165 / 108 134 / 79 111 / 59 93 / 46 79 / 36 40 - 0
18/16 118 / 477 110 / 382 103 / 310 96 / 256 91 / 213 86 / 180 77 / 131 - - - 40 - 0
Form Deck

16/18 179 / 551 167 / 441 156 / 359 146 / 295 137 / 246 124 / 207 101 / 151 - - - 40 - 0
Double
16/16 179 / 589 167 / 471 156 / 383 146 / 316 137 / 263 128 / 222 104 / 162 - - - 40 - 0
14/16 267 / 692 248 / 554 225 / 451 199 / 371 176 / 309 158 / 261 128 / 190 - - - 40 - 0
18/16 135 / 373 125 / 299 117 / 243 - - - - - - - 40 - 0
16/18 204 / 431 189 / 345 177 / 281 - - - - - - - 40 - 0
Triple
16/16 204 / 461 189 / 369 177 / 300 - - - - - - - 40 - 0
Typical Fastener Layouts

14/16 304 / 542 282 / 434 263 / 353 - - - - - - - 40 - 0


Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
9 - 11 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
18/16 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
16/18 40 9 - 11 5 - 11 4-4 than the maximum design or construction spans shown in table above
16/16 40 9 - 11 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

14/16 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
46 www.newmill.com/digital-tools
Deep-Dek® 4.5 Cellular Acoustical

Table of Contents
Roof Decks - Type 4.5DCA Cellular
PROPERTIES
Gage Thickness Cover Weight 7 87 ˝ 12˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 4.32
20/18 0.0358/0.0474
24
4.84 4 58 ˝
18/20 0.0474/0.0358 5.19

Roof Deck
18/18 0.0474/0.0474 5.72
24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 40 4.243 4.283 4.001 4.061 1.051 1.545 25167 37017 1871 588 1164

Composite Deck
20/18 40 4.528 4.787 4.235 4.624 1.053 1.603 25222 38384 1871 588 1164
18/20 40 5.597 5.597 5.490 4.998 1.723 2.008 41279 48097 4224 990 1925
18/18 40 6.040 6.040 5.920 5.623 1.728 2.075 41378 49711 4224 990 1925
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
11 -0 12 -0 13 -0 14 -0 15 -0 16 - 0 18 -0 20 -0 22 -0 24 -0 (ctr / ctr)
20/20 107 / 209 98 / 161 90 / 127 84 / 101 75 / 82 66 / 68 52 / 48 42 / 35 35 / 26 29 / 20 31 - 4
20/18 107 / 223 98 / 172 90 / 135 84 / 108 75 / 88 66 / 72 52 / 51 42 / 37 35 / 28 29 / 21 30 - 7
Single
18/20 180 / 276 165 / 212 152 / 167 140 / 134 122 / 109 107 / 90 85 / 63 69 / 46 57 / 34 48 / 27 40 - 0
18/18 180 / 297 165 / 229 152 / 180 141 / 144 123 / 117 108 / 97 85 / 68 69 / 49 57 / 37 48 / 29 40 - 0
20/20 85 / 509 78 / 392 72 / 308 67 / 247 62 / 201 58 / 165 52 / 116 47 / 85 - - 37 - 4

Form Deck
20/18 85 / 569 78 / 438 72 / 344 67 / 276 62 / 224 58 / 185 52 / 130 47 / 95 - - 36 - 6
Double
18/20 140 / 665 128 / 512 118 / 403 110 / 322 103 / 262 96 / 216 86 / 152 77 / 111 - - 40 - 0
18/18 140 / 717 128 / 552 118 / 435 110 / 348 103 / 283 96 / 233 86 / 164 77 / 119 - - 40 - 0
20/20 96 / 398 88 / 307 81 / 241 76 / 193 71 / 157 - - - - - 37 - 10
20/18 96 / 445 88 / 343 81 / 270 76 / 216 71 / 175 - - - - - 36 - 11
Triple
18/20 159 / 520 146 / 401 135 / 315 125 / 252 117 / 205 - - - - - 40 - 0

Typical Fastener Layouts


18/18 159 / 561 146 / 432 135 / 340 125 / 272 117 / 221 - - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans. General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
7 - 10 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20/20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20/18 40 9-1 5 - 11 4-4 than the maximum design or construction spans shown in table above
18/20 40 9 - 11 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

18/18 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 47
Deep-Dek® 4.5 Cellular Acoustical
Table of Contents

Roof Decks - Type 4.5DCA Cellular


PROPERTIES
Gage Thickness Cover Weight 7 87 ˝ 12˝
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 6.27
16/18 0.0598/0.0474
24
6.65 4 58 ˝
16/16 0.0598/0.0598 7.21
Roof Deck

14/16 0.0747/0.0598 8.33


24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 40 6.447 6.447 6.315 6.261 1.726 2.139 41350 51239 4224 990 1925
Composite Deck

16/18 40 7.446 7.446 7.446 6.646 2.430 2.574 58202 61646 6723 1518 2917
16/16 40 7.951 7.951 7.951 7.363 2.474 2.650 59260 63462 6723 1518 2917
14/16 40 9.354 9.354 9.354 8.624 3.327 3.252 79688 77903 9675 2279 4341
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

13 -0 14 -0 15 -0 16 -0 17 -0 18 -0 20 -0 22 - 0 24 -0 26 -0 (ctr / ctr)
18/16 152 / 192 141 / 154 123 / 125 108 / 103 95 / 86 85 / 72 69 / 53 57 / 40 48 / 31 41 / 24 40 - 0
16/18 230 / 222 198 / 178 172 / 145 152 / 119 134 / 99 120 / 84 97 / 61 80 / 46 67 / 35 57 / 28 40 - 0
Single
16/16 233 / 237 202 / 190 176 / 154 154 / 127 137 / 106 122 / 89 99 / 65 82 / 49 69 / 38 58 / 30 40 - 0
14/16 314 / 279 271 / 223 236 / 182 208 / 150 184 / 125 164 / 105 133 / 77 110 / 58 92 / 44 79 / 35 40 - 0
18/16 118 / 464 110 / 371 103 / 302 96 / 249 91 / 207 86 / 175 77 / 127 - - - 40 - 0
Form Deck

16/18 179 / 536 167 / 429 156 / 349 146 / 287 137 / 240 124 / 202 101 / 147 - - - 40 - 0
Double
16/16 179 / 572 167 / 458 156 / 372 146 / 307 137 / 256 128 / 216 104 / 157 - - - 40 - 0
14/16 267 / 673 248 / 539 225 / 438 199 / 361 176 / 301 158 / 254 128 / 185 - - - 40 - 0
18/16 135 / 363 125 / 291 117 / 236 - - - - - - - 40 - 0
16/18 204 / 419 189 / 336 177 / 273 - - - - - - - 40 - 0
Triple
16/16 204 / 448 189 / 358 177 / 291 - - - - - - - 40 - 0
Typical Fastener Layouts

14/16 304 / 527 282 / 422 263 / 343 - - - - - - - 40 - 0


Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
9 - 11 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
18/16 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
16/18 40 9 - 11 5 - 11 4-4 than the maximum design or construction spans shown in table above
16/16 40 9 - 11 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

14/16 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
48 www.newmill.com/digital-tools
Deep-Dek® 6.0 Cellular

Table of Contents
Roof Decks - Type 6.0DC Cellular
PROPERTIES
7 87 ˝ 12˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 4.83
20/18 0.0358/0.0474 5.40 6 81 ˝
24
18/20 0.0474/0.0358 5.82

Roof Deck
18/18 0.0474/0.0474 6.39
24˝ Coverage ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 40 7.912 8.107 7.351 7.645 1.417 2.207 33937 52850 1391 552 1156

Composite Deck
20/18 40 8.430 9.008 7.759 8.626 1.418 2.286 33960 54745 1391 552 1156
18/20 40 10.713 10.713 10.524 9.414 2.346 2.862 56190 68560 3235 940 1913
18/18 40 11.495 11.495 11.248 10.507 2.335 2.958 55937 70852 3235 940 1913
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
14 -0 15 -0 16 - 0 17 - 0 18 - 0 19 -0 20 -0 22 -0 24 -0 26 -0 (ctr / ctr)
20/20 79 / 189 74 / 154 69 / 127 65 / 106 61 / 89 58 / 76 55 / 65 47 / 49 39 / 38 33 / 30 38 - 7
20/18 79 / 201 74 / 164 69 / 135 65 / 112 61 / 95 58 / 81 55 / 69 47 / 52 39 / 40 33 / 31 37 - 6
Single
18/20 134 / 256 125 / 208 118 / 171 111 / 143 104 / 120 99 / 102 94 / 88 77 / 66 65 / 51 55 / 40 40 - 0
18/18 134 / 275 125 / 223 118 / 184 111 / 153 104 / 129 99 / 110 93 / 94 77 / 71 65 / 55 55 / 43 40 - 0
20/20 66 / 467 62 / 380 58 / 313 54 / 261 51 / 220 49 / 187 46 / 160 - - - 40 - 0

Form Deck
20/18 66 / 519 62 / 422 58 / 348 54 / 290 51 / 244 49 / 208 46 / 178 - - - 40 - 0
Double
18/20 109 / 617 102 / 502 96 / 413 90 / 345 85 / 290 81 / 247 77 / 212 - - - 40 - 0
18/18 109 / 662 102 / 538 96 / 444 90 / 370 85 / 312 81 / 265 77 / 227 - - - 40 - 0
20/20 75 / 365 70 / 297 - - - - - - - - 40 - 0
20/18 75 / 406 70 / 330 - - - - - - - - 40 - 0
Triple
18/20 124 / 483 116 / 393 - - - - - - - - 40 - 0

Typical Fastener Layouts


18/18 124 / 518 116 / 421 - - - - - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans. General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
8-4 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20/20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20/18 40 8-4 5 - 11 4-4 than the maximum design or construction spans shown in table above
18/20 40 9 - 11 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

18/18 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 49
Deep-Dek® 6.0 Cellular
Table of Contents

Roof Decks - Type 6.0DC Cellular


PROPERTIES
7 87 ˝ 12˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 7.00
16/18 0.0598/0.0474 7.44 6 81 ˝
24
16/16 0.0598/0.0598 8.06
Roof Deck

14/16 0.0747/0.0598 9.33


24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 40 12.146 12.146 11.814 11.624 2.331 3.047 55833 72975 3235 940 1913
Composite Deck

16/18 40 14.204 14.204 14.204 12.437 3.514 3.665 84165 87794 6510 1452 2900
16/16 40 15.167 15.167 15.167 13.682 3.500 3.772 83837 90337 6510 1452 2900
14/16 40 17.832 17.832 17.832 16.050 4.779 4.627 114468 110823 10491 2192 4319
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

15 -0 16 -0 17 -0 18 -0 20 -0 22 - 0 24 - 0 26 -0 28 -0 30 -0 (ctr / ctr)
18/16 125 / 236 118 / 194 111 / 162 104 / 137 93 / 100 77 / 75 65 / 58 55 / 45 47 / 36 41 / 29 40 - 0
16/18 194 / 276 181 / 227 171 / 190 161 / 160 140 / 116 116 / 87 97 / 67 83 / 53 72 / 42 62 / 34 40 - 0
Single
16/16 194 / 295 181 / 243 171 / 202 161 / 170 140 / 124 115 / 93 97 / 72 83 / 57 71 / 45 62 / 37 40 - 0
14/16 292 / 346 274 / 285 258 / 238 236 / 200 191 / 146 158 / 110 132 / 85 113 / 67 97 / 53 85 / 43 40 - 0
18/16 102 / 569 96 / 469 90 / 391 85 / 329 77 / 240 - - - - - 40 - 0
Form Deck

16/18 155 / 665 145 / 548 136 / 457 129 / 385 116 / 281 - - - - - 40 - 0
Double
16/16 155 / 710 145 / 585 136 / 488 129 / 411 116 / 300 - - - - - 40 - 0
14/16 230 / 835 216 / 688 203 / 574 192 / 483 173 / 352 - - - - - 40 - 0
18/16 116 / 445 - - - - - - - - - 40 - 0
16/18 176 / 521 - - - - - - - - - 40 - 0
Triple
16/16 176 / 556 - - - - - - - - - 40 - 0
Typical Fastener Layouts

14/16 262 / 654 - - - - - - - - - 40 - 0


Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
9 - 11 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
18/16 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
16/18 40 9 - 11 5 - 11 4-4 than the maximum design or construction spans shown in table above
16/16 40 9 - 11 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

14/16 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
50 www.newmill.com/digital-tools
Deep-Dek® 6.0 Cellular Acoustical

Table of Contents
Roof Decks - Type 6.0DCA Cellular
PROPERTIES
7 87 ˝ 12˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 4.67
20/18 0.0358/0.0474 5.19 6 81 ˝
24
18/20 0.0474/0.0358 5.66

Roof Deck
18/18 0.0474/0.0474 6.18
24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 40 7.735 8.026 7.210 7.647 1.417 2.207 33937 52856 1391 552 1156

Composite Deck
20/18 40 8.242 8.910 7.612 8.615 1.417 2.285 33946 54726 1391 552 1156
18/20 40 10.434 10.434 10.252 9.417 2.350 2.863 56281 68568 3235 940 1913
18/18 40 11.228 11.228 11.012 10.497 2.338 2.957 55994 70835 3235 940 1913
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span

Deep-Dek®
14 -0 15 -0 16 - 0 17 - 0 18 - 0 19 -0 20 -0 22 -0 24 -0 26 -0 (ctr / ctr)
20/20 79 / 185 74 / 150 69 / 124 65 / 103 61 / 87 58 / 74 55 / 63 47 / 48 39 / 37 33 / 29 38 - 10
20/18 79 / 197 74 / 160 69 / 132 65 / 110 61 / 93 58 / 79 55 / 68 47 / 51 39 / 39 33 / 31 37 - 11
Single
18/20 134 / 249 125 / 203 118 / 167 111 / 139 104 / 117 99 / 100 94 / 86 78 / 64 65 / 49 56 / 39 40 - 0
18/18 134 / 268 125 / 218 118 / 180 111 / 150 104 / 126 99 / 107 93 / 92 77 / 69 65 / 53 55 / 42 40 - 0
20/20 66 / 462 62 / 376 58 / 310 54 / 258 51 / 218 49 / 185 46 / 159 - - - 40 - 0

Form Deck
20/18 66 / 513 62 / 417 58 / 344 54 / 287 51 / 242 49 / 205 46 / 176 - - - 40 - 0
Double
18/20 109 / 601 102 / 489 96 / 403 90 / 336 85 / 283 81 / 240 77 / 206 - - - 40 - 0
18/18 109 / 647 102 / 526 96 / 433 90 / 361 85 / 304 81 / 259 77 / 222 - - - 40 - 0
20/20 75 / 362 70 / 294 - - - - - - - - 40 - 0
20/18 75 / 402 70 / 327 - - - - - - - - 40 - 0
Triple
18/20 124 / 470 116 / 382 - - - - - - - - 40 - 0

Typical Fastener Layouts


18/18 124 / 506 116 / 412 - - - - - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans. General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
8-4 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20/20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20/18 40 8-4 5 - 11 4-4 than the maximum design or construction spans shown in table above
18/20 40 9 - 11 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

18/18 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 51
Deep-Dek® 6.0 Cellular Acoustical
Table of Contents

Roof Decks - Type 6.0DCA Cellular


PROPERTIES
7 87 ˝ 12˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 6.74
16/18 0.0598/0.0474 7.24 6 81 ˝
24
16/16 0.0598/0.0598 7.80
Roof Deck

14/16 0.0747/0.0598 9.06


24˝ Coverage ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 40 11.865 11.878 11.570 11.590 2.332 3.044 55861 72920 3235 940 1913
Composite Deck

16/18 40 13.824 13.824 13.824 12.429 3.486 3.665 83492 87779 6510 1452 2900
16/16 40 14.749 14.749 14.749 13.649 3.508 3.769 84032 90281 6510 1452 2900
14/16 40 17.351 17.351 17.351 16.019 4.741 4.624 113551 110765 10491 2193 4319
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
Versa-Dek®

15 -0 16 -0 17 -0 18 -0 20 -0 22 - 0 24 - 0 26 -0 28 -0 30 -0 (ctr / ctr)
18/16 125 / 230 118 / 190 111 / 158 104 / 133 93 / 97 77 / 73 65 / 56 55 / 44 48 / 35 41 / 29 40 - 0
16/18 194 / 269 181 / 221 171 / 184 161 / 155 139 / 113 115 / 85 97 / 66 82 / 52 71 / 41 62 / 34 40 - 0
Single
16/16 194 / 286 181 / 236 171 / 197 161 / 166 140 / 121 116 / 91 97 / 70 83 / 55 71 / 44 62 / 36 40 - 0
14/16 292 / 337 274 / 278 258 / 232 234 / 195 189 / 142 156 / 107 131 / 82 112 / 65 97 / 52 84 / 42 40 - 0
18/16 102 / 556 96 / 458 90 / 382 85 / 322 77 / 235 - - - - - 40 - 0
Form Deck

16/18 155 / 647 145 / 533 136 / 445 129 / 375 116 / 273 - - - - - 40 - 0
Double
16/16 155 / 691 145 / 569 136 / 475 129 / 400 116 / 291 - - - - - 40 - 0
14/16 230 / 813 216 / 670 203 / 558 192 / 470 173 / 343 - - - - - 40 - 0
18/16 116 / 435 - - - - - - - - - 40 - 0
16/18 176 / 507 - - - - - - - - - 40 - 0
Triple
16/16 176 / 541 - - - - - - - - - 40 - 0
Typical Fastener Layouts

14/16 262 / 636 - - - - - - - - - 40 - 0


Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double Triple 7. Maximum cantilever spans shown are based on the following criteria:
9 - 11 5 - 11 4-4 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
18/16 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
16/18 40 9 - 11 5 - 11 4-4 than the maximum design or construction spans shown in table above
16/16 40 9 - 11 5 - 11 4-4 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

14/16 40 9 - 11 5 - 11 4-4 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
52 www.newmill.com/digital-tools
Deep-Dek® 7.5 Cellular

Table of Contents
Roof Decks - Type 7.5DC Cellular
PROPERTIES
7 87 ˝ 12˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 5.17
20/18 0.0358/0.0474 5.74 7 85 ˝
24
18/20 0.0474/0.0358 6.27

Roof Deck
18/18 0.0474/0.0474 6.85
ICC-ES APPROVED
24˝ Coverage REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)

Composite Deck
(ksi)
20/20 40 12.639 13.197 11.608 12.445 1.787 2.922 42796 69981 1108 521 1148
20/18 40 13.461 14.636 12.234 13.997 1.787 3.030 42795 72584 1108 521 1148
18/20 40 17.211 17.211 16.796 15.352 2.958 3.785 70852 90657 2575 896 1902
18/18 40 18.349 18.349 17.772 17.060 2.948 3.916 70602 93787 2575 896 1902
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS

Deep-Dek®
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
17 -0 18 - 0 19 -0 20 -0 22 -0 24 -0 26 -0 28 -0 30 -0 32 -0 (ctr / ctr)
20/20 61 / 169 58 / 142 55 / 121 52 / 104 47 / 78 43 / 60 40 / 47 36 / 38 32 / 31 28 / 25 40 - 0
20/18 61 / 180 58 / 151 55 / 129 52 / 110 47 / 83 43 / 64 40 / 50 36 / 40 32 / 33 28 / 27 40 - 0
Single
18/20 105 / 230 100 / 193 94 / 164 90 / 141 81 / 106 75 / 82 69 / 64 60 / 51 52 / 42 46 / 34 40 - 0

Form Deck
18/18 105 / 245 100 / 206 94 / 175 90 / 150 81 / 113 75 / 87 69 / 68 60 / 55 52 / 45 46 / 37 40 - 0
20/20 54 / 425 51 / 358 48 / 304 46 / 261 - - - - - - 40 - 0
20/18 54 / 471 51 / 397 48 / 337 46 / 289 - - - - - - 40 - 0
Double
18/20 90 / 554 85 / 466 80 / 397 76 / 340 - - - - - - 40 - 0
18/18 90 / 590 85 / 497 80 / 423 76 / 363 - - - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:

Typical Fastener Layouts


● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.

General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double 7. Maximum cantilever spans shown are based on the following criteria:
6-3 5 - 11 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20/20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20/18 40 6-3 5 - 11 than the maximum design or construction spans shown in table above
18/20 40 9 - 11 5 - 11 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

18/18 40 9 - 11 5 - 11 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 53
Deep-Dek® 7.5 Cellular
Table of Contents

Roof Decks - Type 7.5DC Cellular


PROPERTIES
Gage Thickness Cover Weight 7 87 ˝ 12˝
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 7.46
16/18 0.0598/0.0474 8.02
24 7 85 ˝
16/16 0.0598/0.0598 8.64
Roof Deck

14/16 0.0747/0.0598 10.05

24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
Composite Deck

(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 40 19.380 19.503 18.646 18.832 2.942 4.038 70476 96718 2575 896 1902
16/18 40 23.094 23.094 23.094 20.217 4.447 4.846 106525 116074 5178 1394 2886
16/16 40 24.659 24.659 24.659 22.170 4.422 4.992 105918 119561 5178 1394 2886
14/16 40 28.977 28.977 28.977 26.028 6.346 6.118 152001 146538 10113 2117 4300
Notes: 1. Section properties are calculated in accordance with the AISI S100-16.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Versa-Dek®

Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
20 -0 21 -0 22 - 0 23 - 0 24 - 0 26 - 0 28 - 0 30 -0 32 -0 34 -0 (ctr / ctr)
18/16 90 / 159 85 / 137 81 / 119 78 / 104 75 / 92 69 / 72 60 / 58 52 / 47 46 / 39 41 / 32 40 - 0
16/18 139 / 189 133 / 163 127 / 142 121 / 124 116 / 110 105 / 86 91 / 69 79 / 56 69 / 46 61 / 39 40 - 0
Single
16/16 139 / 202 133 / 175 127 / 152 121 / 133 116 / 117 104 / 92 90 / 74 78 / 60 69 / 49 61 / 41 40 - 0
Form Deck

14/16 212 / 237 202 / 205 192 / 178 184 / 156 176 / 137 150 / 108 129 / 87 113 / 70 99 / 58 88 / 48 40 - 0
18/16 76 / 385 72 / 333 - - - - - - - - 40 - 0
16/18 115 / 456 110 / 394 - - - - - - - - 40 - 0
Double
16/16 115 / 487 110 / 421 - - - - - - - - 40 - 0
14/16 172 / 573 164 / 495 - - - - - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
Typical Fastener Layouts

● ANSI/SDI RD-2017 Standard for Steel Roof Deck


● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double 7. Maximum cantilever spans shown are based on the following criteria:
9 - 11 5 - 11 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
18/16 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
16/18 40 9 - 11 5 - 11 than the maximum design or construction spans shown in table above
16/16 40 9 - 11 5 - 11 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

14/16 40 9 - 11 5 - 11 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
54 www.newmill.com/digital-tools
Deep-Dek® 7.5 Cellular Acoustical

Table of Contents
Roof Decks - Type 7.5DCA Cellular
PROPERTIES
Gage Thickness Cover Weight 7 87 ˝ 12˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 5.01
20/18 0.0358/0.0474 5.54
24 7 85 ˝
18/20 0.0474/0.0358 6.12

Roof Deck
18/18 0.0474/0.0474 6.64

24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)

Composite Deck
(ksi)
20/20 40 12.361 13.064 11.391 12.445 1.787 2.922 42791 69984 1108 521 1148
20/18 40 13.164 14.476 12.008 13.976 1.786 3.029 42780 72554 1108 521 1148
18/20 40 16.840 16.840 16.474 15.354 2.961 3.785 70923 90663 2575 896 1902
18/18 40 17.934 17.934 17.416 17.041 2.950 3.914 70649 93759 2575 896 1902
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.

Versa-Dek®
Long-Span Composite
ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS

Deep-Dek®
Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
17 -0 18 - 0 19 -0 20 -0 22 -0 24 -0 26 -0 28 -0 30 -0 32 -0 (ctr / ctr)
20/20 61 / 165 58 / 139 55 / 118 52 / 101 47 / 76 43 / 59 40 / 46 36 / 37 32 / 30 28 / 25 40 - 0
20/18 61 / 176 58 / 148 55 / 126 52 / 108 47 / 81 43 / 62 40 / 49 36 / 39 32 / 32 28 / 26 40 - 0
Single
18/20 105 / 225 100 / 189 94 / 161 90 / 138 81 / 104 75 / 80 69 / 63 60 / 50 53 / 41 46 / 34 40 - 0

Form Deck
18/18 105 / 239 100 / 202 94 / 171 90 / 147 81 / 110 75 / 85 69 / 67 60 / 54 52 / 44 46 / 36 40 - 0
20/20 54 / 420 51 / 354 48 / 301 46 / 258 - - - - - - 40 - 0
20/18 54 / 466 51 / 392 48 / 334 46 / 286 - - - - - - 40 - 0
Double
18/20 90 / 542 85 / 456 80 / 388 76 / 333 - - - - - - 40 - 0
18/18 90 / 577 85 / 486 80 / 413 76 / 354 - - - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:

Typical Fastener Layouts


● ANSI/SDI RD-2017 Standard for Steel Roof Deck
● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.

General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double 7. Maximum cantilever spans shown are based on the following criteria:
6-3 5 - 11 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
20/20 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
20/18 40 6-3 5 - 11 than the maximum design or construction spans shown in table above
18/20 40 9 - 11 5 - 11 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

18/18 40 9 - 11 5 - 11 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 55
Deep-Dek® 7.5 Cellular Acoustical
Table of Contents

Roof Decks - Type 7.5DCA Cellular


PROPERTIES
7 87 ˝ 12˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 7.20
16/18 0.0598/0.0474 7.81 7 85 ˝
24
16/16 0.0598/0.0598 8.37
Roof Deck

14/16 0.0747/0.0598 9.79


24˝ Coverage
ICC-ES APPROVED
REFER TO ESR-2657

ASD SECTION PROPERTIES DESIGN STRENGTHS


Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
Composite Deck

(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 40 18.937 19.273 18.270 18.775 2.943 4.035 70502 96637 2575 896 1902
16/18 40 22.483 22.483 22.483 20.200 4.458 4.845 106773 116047 5178 1394 2886
16/16 40 23.982 23.982 23.982 22.115 4.430 4.988 106112 119477 5178 1394 2886
14/16 40 28.205 28.205 28.205 25.976 6.292 6.114 150718 146450 10113 2117 4300
Notes: 1. Section properties are calculated in accordance with the AISI S100-16, with perforation modifiers.
2. Web crippling design strengths* are based on minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing.
Deep-Dek®
Long-Span Composite

ALLOWABLE UNIFORM LOADS AND MAXIMUM CONSTRUCTION SPANS


Versa-Dek®

Allowable Uniform Total Load (psf) / Load that Produces L/240 Deflection (psf) SDI Max.
Span Constr.
Gage Center to Center Span (ft - in)
Condition Span
20 -0 21 -0 22 - 0 23 - 0 24 - 0 26 - 0 28 - 0 30 -0 32 -0 34 -0 (ctr / ctr)
18/16 90 / 155 85 / 134 81 / 117 78 / 102 75 / 90 69 / 71 60 / 57 52 / 46 46 / 38 41 / 32 40 - 0
16/18 139 / 184 133 / 159 127 / 138 121 / 121 116 / 107 105 / 84 91 / 67 79 / 55 70 / 45 62 / 37 40 - 0
Single
16/16 139 / 197 133 / 170 127 / 148 121 / 129 116 / 114 105 / 89 90 / 72 79 / 58 69 / 48 61 / 40 40 - 0
Form Deck

14/16 212 / 231 202 / 200 192 / 174 184 / 152 174 / 134 149 / 105 128 / 84 112 / 68 98 / 56 87 / 47 40 - 0
18/16 76 / 381 72 / 329 - - - - - - - - 40 - 0
16/18 115 / 444 110 / 384 - - - - - - - - 40 - 0
Double
16/16 115 / 474 110 / 409 - - - - - - - - 40 - 0
14/16 172 / 557 164 / 481 - - - - - - - - 40 - 0
Notes: 3. Allowable Uniform Loads and maximum construction spans shown are based on the following criteria:
Typical Fastener Layouts

● ANSI/SDI RD-2017 Standard for Steel Roof Deck


● Minimum bearing lengths of 4'' for end bearing and 6'' for interior bearing. Check web crippling if minimums are not met.
4. Maximum construction spans shown include a check for deck self-weight plus a nominal 200 lbs. concentrated load supported by a one foot section of
deck per SDI criteria which exceeds the IBC requirement of a 300 lbs. roof maintenance load distributed over an area of 2 1/2 feet by 2 1/2 feet per
Section 1607.4 and Table 1607.1.
5. ''Load that Produces L/240 Deflection'' values shown in RED exceed the ''Allowable Uniform Total Load''. These loads may be used to
determine the deck capacity under deflection limits more stringent than L/240. In no case shall the ''Allowable Uniform Total Load'' be exceeded.
6. See website at www.newmill.com for Factory Mutual approved deck types and maximum FM construction spans.
General Information

MAXIMUM CANTILEVER SPANS


Fy Back-Span Condition Notes:
Gage
(ksi) Single Double 7. Maximum cantilever spans shown are based on the following criteria:
9 - 11 5 - 11 ● ANSI/SDI RD-2017 Standard for Steel Roof Deck
18/16 40
● Adjacent span assumed to be at least 3 mes longer than the canlever and no greater
16/18 40 9 - 11 5 - 11 than the maximum design or construction spans shown in table above
16/16 40 9 - 11 5 - 11 ● Bearing width at perimeter support assumed to be 6'' minimum
Code of Standard Practice

14/16 40 9 - 11 5 - 11 ● Design total uniform load of 45 psf in conjuncon with a 100 lb.
concentrated load.

Discover the easiest way to specify Steel Roof and Floor Deck:
56 www.newmill.com/digital-tools
Long-Span Composite
Table of Contents Roof Deck Composite Deck Form Deck Typical Fastener Layouts General Information Code of Standard Practice
Versa-Dek® Deep-Dek®
Long-Span Composite
Code of Standard Practice General Information Typical Fastener Layouts Form Deck Composite Deck Roof Deck Table of Contents
Versa-Dek® Deep-Dek®

Composite Deck
Table of Contents
Composite deck has embossments in the vertical ribs that bond with the
concrete slab to develop a composite floor system. Composite deck acts as a form
during the concrete pour. The resulting composite floor system provides superior
strength and stiffness. Click on the links below to view load tables.

Roof Deck
Standard Composite

Composite Deck
1.5 Composite Deck......................................................................................... 60 – 63
1.5-inch composite deck, standard
and interlocking options available

2.0 Composite Deck........................................................................................64 – 65

Versa-Dek®
Long-Span Composite
2-inch composite deck

3.0 Composite Deck........................................................................................ 66 – 67

Deep-Dek®
3-inch composite deck

Cellular Composite

Form Deck
1.5 Cellular Composite Deck........................................................................ 68 – 75
1.5-inch cellular composite deck, available
with or without acoustical properties

Typical Fastener Layouts


2.0 Cellular Composite Deck........................................................................ 76 – 83
2-inch cellular composite deck, available
with or without acoustical properties

3.0 Cellular Composite Deck........................................................................ 84 – 91


3-inch cellular composite deck, available General Information
with or without acoustical properties
Code of Standard Practice

newmill.com 59
1.5CD, 1.5CDI Composite Deck
Table of Contents

LIGHTWEIGHT CONCRETE
Composite Decks

- Types 1.5CD, 1.5CDI
185 ˝ 2 21 ˝
PROPERTIES
Thickness Cover Weight
Gage (in) (in) (psf)
22 0.0295 1.63 1 21 ˝
20 0.0358 1.98 ICC-ES APPROVED
18 0.0474
36
2.62 36˝ Coverage ICC-ES Approved -
REFER TO ESR-3818
Refer to ESR-3818
Roof Deck

16 0.0598 3.30
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.480 0.163 0.175 0.157 0.175 0.176 0.183 4215 4391 2009 654 1181
20 40 0.582 0.205 0.213 0.201 0.213 0.224 0.235 5375 5624 2428 932 1696
18 40 0.770 0.280 0.281 0.279 0.281 0.304 0.315 7291 7553 3192 1557 2858
16 40 0.971 0.355 0.355 0.355 0.355 0.390 0.395 9332 9454 3996 2381 4396
CONSTRUCTION CLEAR SPANS
Composite Deck

Concrete Maximum Construction Concrete Notes:


Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
Depth (in) 3 2 AISI S100-16.
(psf) Single Double Triple Cantilever (ft /ft )
22 6 - 2 7 - 3 7 - 4 2 - 0 2. Web crippling design strengths* and maximum construction
20 7 - 4 8 - 5 8 - 9 2 - 6 spans are based on 1 1/2'' for end bearing and 3'' for interior
3 1/2 23 0.213
18 9 - 0 9 - 9 10 - 1 3 - 3 bearing. Check web crippling if minimums are not met.
16 10 - 6 10 - 10 11 - 3 3 - 9 3. Maximum construction spans are based on ANSI/SDI C-2017
22 5 - 10 6 - 11 7 - 0 2 - 0 Standard for Composite Steel Floor Deck and the following
20 7 - 0 8 - 3 8 - 4 2 - 5
4 28 0.255 construction loading:
18 8 - 7 9 - 9 10 - 1 3 - 2
Lightweight Concrete (110 pcf)

● Deck self-weight and concrete weight plus worst-case of


Deep-Dek®

16 9 - 11 10 - 10 11 - 3 3 - 9
Long-Span Composite

22 5 - 8 6 - 8 6 - 9 1 - 11 either a 150 lb.concentrated load or a 20 psf


20 6 - 8 7 - 10 7 - 11 2 - 5 uniform load; or
4 1/2 33 0.297
18 8 - 2 9 - 6 9 - 9 3 - 0 ● Deck self-weight plus a 50 psf uniform construcon
16 9 - 6 10 - 7 10 - 11 3 - 7 load, whichever controls.
22 5 - 5 6 - 5 6 - 6 1 - 11 4. Concrete weights do not include weight of deck.
Versa-Dek®

20 6 - 5 7 - 7 7 - 8 2 - 4 5. Deck profile has been accounted for in determining concrete


5 37 0.338
18 7 - 10 9 - 2 9 - 4 3 - 0 volumes. Deck and support deflections have not been
16 9 - 1 10 - 2 10 - 6 3 - 6
22 included in concrete volumes or weights.
5 - 3 6 - 2 6 - 3 1 - 10
20 6 - 2 7 - 3 7 - 4 2 - 3 6. Cantilever clear spans assume adjacent clear span is at least
5 1/2 42 0.380 3 times longer than the cantilever clear span and no greater
18 7 - 7 8 - 10 8 - 11 2 - 11
16 8 - 9 9 - 10 10 - 2 3 - 4 than spans shown. Bearing width at perimeter support
22 5 - 1 6 - 0 6 - 1 1 - 10 assumed to be 3''minimum. Contact New Millennium
20 6 - 0 7 - 0 7 - 1 2 - 3 otherwise.
6 46 0.422
18 7 - 4 8 - 6 8 - 8 2 - 10
Form Deck

16 8 - 6 9 - 6 9 - 10 3 - 3
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric (in2/ft)
Lightweight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)

22 284 238 202 173 149 129 112 86 67


20 339 285 242 208 179 156 134 98 73 6x6 -
3 1/2 0.028
Typical Fastener Layouts

18 400 366 312 262 216 180 152 111 83 W1.4xW1.4


16 400 400 359 292 240 200 169 123 92
22 359 302 256 219 189 164 143 110 86
20 400 361 308 264 228 199 174 135 107 6x6 -
4 0.028
18 400 400 397 342 297 259 225 164 123 W1.4xW1.4
16 400 400 400 400 355 296 249 182 137
22 400 368 313 268 232 201 176 136 106
20 400 400 376 323 280 244 214 167 132 6x6 -
4 1/2 0.028
18 400 400 400 400 365 319 281 221 174 W1.4xW1.4
16 400 400 400 400 400 395 348 257 193
22 400 400 372 319 276 240 210 162 127
20 400 400 400 385 334 291 255 199 158 6x6 -
5 0.040
18 400 400 400 400 400 382 336 265 212 W2.0xW2.0
General Information

16 400 400 400 400 400 400 400 331 263


22 400 400 400 371 321 279 244 190 149
20 400 400 400 400 389 339 298 233 185 6x6 -
5 1/2 0.040
18 400 400 400 400 400 400 393 310 248 W2.0xW2.0
16 400 400 400 400 400 400 400 388 313
22 400 400 400 400 367 319 280 217 171
20 400 400 400 400 400 389 341 267 213 4x4 -
6 0.042
18 400 400 400 400 400 400 400 356 286 W1.4xW1.4
16 400 400 400 400 400 400 400 400 360
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
60 www.newmill.com/digital-tools
1.5CD, 1.5CDI Composite Deck

Table of Contents
Composite Decks
Composite Decks -- Types
Types 1.5CD,
1.5CD, 1.5CDI
1.5CDI
NORMAL-WEIGHT CONCRETE
PROPERTIES 6˝ 185 ˝
PROPERTIES 2 21 ˝
Thickness Coverage Weight
Gage Thickness Cover Weight
(in) (in) (psf)
Gage (in) (in) (psf)
22 0.0295 1.63
22
20 0.0295
0.0358 1.63
1.98
1 21 ˝
20
18 0.0358
0.0474
36
36
1.98
2.62 ICC-ES
ICC-ES Approved
ICC-ES Approved --
APPROVED
18 0.0474 2.62 36˝ Coverage Refer
16
16
0.0598
0.0598
3.30
3.30 Refer to
REFER to ESR-3818
TO ESR-3818
ESR-3818

Roof Deck
ASD
ASD SECTION PROPERTIES
SECTION PROPERTIES DESIGN STRENGTHS
DESIGN STRENGTHS (No
(No Concrete Fill)
Concrete Fill)
F A I 1 Span I 2+ Span I I S S Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage Fyy Ass IDD 1 Span IDD 2+ Span Ipp Inn Spp Snn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage (ksi) (in22/ft) (in44/ft) 4
(in4 /ft)
4
(in4 /ft)
4
(in4 /ft)
3
(in3 /ft)
3
(in3 /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.480 0.163 0.175 0.157 0.175 0.176 0.183 4215 4391 2009 654 1181
22 40 0.480 0.163 0.175 0.157 0.175 0.176 0.183 4215 4391 2009 654 1181
20 40 0.582 0.205 0.213 0.201 0.213 0.224 0.235 5375 5624 2428 932 1696
20 40 0.582 0.205 0.213 0.201 0.213 0.224 0.235 5375 5624 2428 932 1696
18 40 0.770 0.280 0.281 0.279 0.281 0.304 0.315 7291 7553 3192 1557 2858
18 40 0.770 0.280 0.281 0.279 0.281 0.304 0.315 7291 7553 3192 1557 2858
16 40 0.971 0.355 0.355 0.355 0.355 0.390 0.395 9332 9454 3996 2381 4396
16 40 0.971 0.355 0.355 0.355 0.355 0.390 0.395 9332 9454 3996 2381 4396
CONSTRUCTION CLEAR
CONSTRUCTION CLEAR SPANS
SPANS
Concrete Maximum Construction
Construction Concrete Notes:

Composite Deck
Total Slab
Slab Concrete Maximum Concrete Notes:
Total Gage Weight Clear Span
Span (ft
(ft -- in)
in) Volume 1. Section properties are calculated in accordance with the
Depth (in) Gage Weight Clear Volume 1. Section properties are calculated in accordance with the
Depth (in) (psf) Single Double Triple Cantilever (ft 3
/ft22))
(ft3/ft
AISI S100-16.
AISI S100-16.
(psf) Single Double Triple Cantilever 2. Web crippling design strengths* and maximum construction
22
22 56 -- 92 67 -- 93 67 -- 4
10 22 -- 00 2. Web
spans crippling
are based design
on 1strengths*
1/2'' for endand maximum
bearing and construction
3'' for interior
20
20 67 -- 94 88 -- 05 88 -- 19 22 -- 56 spans are Check
based on 1 1/2'' for end bearing and
are3''
notfor interior
33 1/2
1/2
18
23
31 0.213
0.213 bearing. web crippling if minimums met.
18 89 -- 40 99 -- 89 10
9 -- 1
11 33 -- 13 3. bearing.
MaximumCheck web crippling
construction spansifareminimums
based onare not met.C-2017
ANSI/SDI
16
16 10
9 -- 86 10
10 -- 910 11
11 -- 13 33 -- 89 Standard for Compositespans
SteelareFloor Deck
3. Maximum construction based onand the following
ANSI/SDI C-2017
22
22 55 -- 510 66 -- 511 67 -- 60 12 -- 0
11 construction loading: Steel Floor Deck and the following
20 Standard for Composite
44
20 28 67 -- 50 78 -- 73 78 -- 84 22 -- 45 0.255 ● Deck self-weight and concrete weight plus worst-case of
pcf)

37 0.255 construction loading:


(145pcf)

18
18 78 -- 7
11 99 -- 29 10
9 -- 41 33 -- 02 either a 150 lb. concentrated load or a 20 psf
16 99 -- 111 10 -- 210 11 -- 63 33 -- 69
● Deck self-weight and concrete weight plus worst-case of

Versa-Dek®
16 10 10 uniform load; or

Long-Span Composite
Concrete(110

22
22 55 -- 38 66 -- 28 66 -- 39 11 -- 11
10 ● either a 150 lb.concentrated
Deck self-weight plus a 50 psf load or a 20
uniform psf
construction
20
20 66 -- 28 77 -- 310 77 -- 411 22 -- 35 uniform load; or controls.
44 1/2
1/2 33 0.297 load, whichever
Light Weight Concrete

18 43 0.297
18 78 -- 62 89 -- 96 89 -- 9
10 23 -- 0
10 4. ● Deck self-weight
Concrete weights do plus
nota include
50 psf uniform construcon
weight of deck.
16
16 89 -- 86 10
9 -- 87 10
10 -- 111 33 -- 47 5. Deckload, whichever
profile controls.
has been accounted for in determining concrete
22
22 55 -- 05 56 -- 5
11 56 -- 6
11 11 -- 11
10 volumes. weights
Deck and
20 4. Concrete do support deflections
not include have
weight of not been
deck.
56 -- 5 67 -- 7 77 -- 08 22 -- 34
Normal-Weight

20 11 11
55 37 0.338

Deep-Dek®
included
5. Deck in concrete
profile has beenvolumes
accounted or weights.
for in determining concrete
18 49 0.338
18 77 -- 210 89 -- 42 89 -- 64 23 -- 90 6. Cantilever clear spans assume adjacent clear span is at least
volumes. Deck and support deflections have not been
16
16 89 -- 41 10
9 -- 32 10
9 -- 76 33 -- 26 3 times longer than the cantilever clear span and no greater
22
22 45 -- 3
10 56 -- 82 56 -- 93 11 -- 910 included in concrete volumes or weights.
than spans shown. Bearing width at perimeter support
20
20 56 -- 82 67 -- 83 67 -- 94 22 -- 23 6. Cantilever clear spans assumeContact
adjacentNMBS
clear span is at least
55 1/2
1/2
18
42
55 0.380
0.380 assumed to be 3'' minimum. otherwise.
18 67 -- 7
11 88 -- 010 88 -- 211 22 -- 811 3 times longer than the cantilever clear span and no greater
16
16 88 -- 09 89 -- 10
11 10
9 -- 32 33 -- 14 than spans shown. Bearing width at perimeter support
22
22 45 -- 81 56 -- 60 56 -- 71 11 -- 910 assumed to be 3''minimum. Contact New Millennium
20
20 56 -- 60 67 -- 50 67 -- 61 22 -- 13
66 18
46
61 0.422
0.422 otherwise.
18 67 -- 84 78 -- 96 78 -- 8
10 22 -- 710

Form Deck
16
16 78 -- 96 89 -- 76 89 -- 10
11 23 -- 3
11
SLAB DESIGN
SLAB DESIGN -- ALLOWABLE
ALLOWABLE SUPERIMPOSED
SUPERIMPOSED UNIFORM
UNIFORM LOADS
LOADS AND
AND MINIMUM
MINIMUM SDI
SDI SLAB
SLAB REINFORCEMENT
REINFORCEMENT
Total Slab
Total Slab Allowable Superimposed
Allowable Superimposed Uniform
Uniform LoadLoad (psf)
(psf) Recommended Wire
Recommended
Depth
Depth Gage
Gage Clear Span
Clear Span (ft
(ft -- in)
in) Welded Wire
Welded Wire Area
(in) Fabric (in2/ft)
9)

66 -- 00 66 -- 66 77 -- 00 77 -- 66 88 -- 00 88 -- 66 99 -- 00 10 -- 00 11 -- 00 2
Fabric
psi,n n= =14)

(in) 10 11 (in /ft)


22
22 284
294 238
246 202
207 173
176 149
151 129
130 112
113 86
85 67
65
20
20 339
354 285
297 242
251 208
215 179
185 156
160 134
139 98
106 73
82 6x6 --
6x6
33 1/2
1/2 0.028
0.028
3000psi,

Typical Fastener Layouts


18
18 400
400 366
386 312
328 262
281 216
243 180
212 152
185 111
139 83
105 W1.4xW1.4
W1.4xW1.4
16
16 400
400 400
400 359
400 292
349 240
301 200
251 169
212 123
154 92
116
pcf,f'cf'c= =3000

22
22 359
370 302
310 256
262 219
223 189
191 164
165 143
143 110
109 86
83
20
20 400
400 361
375 308
318 264
272 228
234 199
203 174
177 135
136 107
105 6x6 --
6x6
44 18 400 400 397 342 297 259 225 164 123 W1.4xW1.4
0.028
0.028
18 400 400 400 357 309 269 236 183 145 W1.4xW1.4
16
16 400
400 400
400 400
400 400
400 355
385 296
336 249
295 182
229 137
172
145pcf,

22
22 400
400 368
377 313
319 268
272 232
234 201
202 176
175 136
133 106
103
20 400 400 376 323 280 244 214 167 132 6x6 --
(γc= =110

20 400 400 387 331 286 248 216 167 130 6x6
44 1/2
1/2
18 400 400 400 400 365 319 281 221 174 W1.4xW1.4
0.028
0.028
18 400 400 400 400 378 330 289 225 178 W1.4xW1.4
16
16 400
400 400
400 400
400 400
400 400
400 395
400 348
363 257
285 193
228
Concrete(γc

22
22 400
400 400
400 372
378 319
322 276
277 240
240 210
208 162
159 127
123
Light Weight Concrete

20
20 400
400 400
400 400
400 385
393 334
339 291
295 255
258 199
199 158
156 6x6 --
6x6
55 18 400 400 400 400 400 382 336 265 212 W2.0xW2.0
0.040
0.040
18 400 400 400 400 400 392 344 269 213 W2.0xW2.0
16 400 400 400 400 400 400 400 331 263
General Information
16 400 400 400 400 400 400 400 341 273
Normal-Weight

22
22 400
400 400
400 400
400 371
374 321
322 279
279 244
242 190
186 149
144
20
20 400
400 400
400 400
400 400
400 389
394 339
343 298
300 233
232 185
182 6x6 --
6x6
55 1/2
1/2
18 400 400 400 400 400 400 393 310 248 W2.0xW2.0
0.040
0.040
18 400 400 400 400 400 400 400 314 249 W2.0xW2.0
16
16 400
400 400
400 400
400 400
400 400
400 400
400 400
400 388
398 313
319
22
22 400
400 400
400 400
400 400
400 367
367 319
318 280
277 217
212 171
165
20
20 400
400 400
400 400
400 400
400 400
400 389
392 341
342 267
265 213
208 4x4 --
4x4
66 18 400 400 400 400 400 400 400 356 286 W1.4xW1.4
0.042
0.042
18 400 400 400 400 400 400 400 360 286 W1.4xW1.4
16
16 400
400 400
400 400
400 400
400 400
400 400
400 400
400 400
400 360
366
Notes: 7.
Notes: 7. Welded
Welded wire
wire fabric
fabric shown
shown in
in the
the table
table below
above is the SDI
is the minimum required
SDI minimum required for
for temperature
temperatureand
andshrinkage
shrinkage (0.00075
(0.00075 xx concrete
concrete area above top
area above top of
of deck).
deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
Code of Standard Practice

●●Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
Single span conditions without negative bending reinforcing over supports.
●●Single span condions
The presence of shearwithout negave
studs have bending
not been reinforcing
considered, over strength
design supports.may be increased if shear studs are used.
●●The
Slabpresence of is
deflection shear studs
limited have not been
to minimum considered,
of Clear Span/360design strength
or 1'' under may be
service increased
level if shearloading.
superimposed studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 61
1.5CDR Composite Deck
Table of Contents

LIGHTWEIGHT CONCRETE
Composite Decks4-˝ Type 1.5CDR 3
8
PROPERTIES
Thickness Cover Weight 1 21 ˝
Gage (in) (in) (psf)

22 0.0295 1.63 3 21 ˝
20 0.0358 1.98 ICC-ES APPROVED
36
18 0.0474 2.62 36˝ Coverage REFER TO ESR-3818
Roof Deck

16 0.0598 3.30
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.480 0.175 0.175 0.175 0.157 0.183 0.176 4391 4215 2009 654 1181
20 40 0.582 0.213 0.213 0.213 0.201 0.235 0.224 5624 5375 2428 932 1696
18 40 0.770 0.281 0.281 0.281 0.279 0.315 0.304 7553 7291 3192 1557 2858
16 40 0.971 0.355 0.355 0.355 0.355 0.395 0.390 9454 9332 3996 2381 4396
CONSTRUCTION CLEAR SPANS
Composite Deck

Concrete Maximum Construction Concrete Notes:


Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
Depth (in) AISI S100-16.
(psf) Single Double Triple Cantilever (ft3/ft2)
22 6 - 1 7 - 2 7 - 3 1 - 11 2. Web crippling design strengths* and maximum construction
20 7 - 3 8 - 3 8 - 7 2 - 4 spans are based on 1 1/2'' for end bearing and 3'' for interior
3 1/2 27 0.250
18 8 - 10 9 - 7 9 - 11 3 - 1 bearing. Check web crippling if minimums are not met.
16 10 - 0 10 - 9 11 - 2 3 - 8 3. Maximum construction spans are based on ANSI/SDI C-2017
22 5 - 10 6 - 11 7 - 0 1 - 11 Standard for Composite Steel Floor Deck and the following
20 6 - 11 8 - 1 8 - 3 2 - 4
4 32 0.291 construction loading:
18 8 - 5 9 - 5 9 - 9 3 - 0
Lightweight Concrete (110 pcf)

● Deck self-weight and concrete weight plus worst-case of


Deep-Dek®

16 9 - 6 10 - 7 10 - 11 3 - 7
Long-Span Composite

22 5 - 7 6 - 8 6 - 8 1 - 10 either a 150 lb.concentrated load or a 20 psf


20 6 - 8 7 - 9 7 - 11 2 - 3 uniform load; or
4 1/2 37 0.333
18 8 - 1 9 - 0 9 - 4 2 - 11 ● Deck self-weight plus a 50 psf uniform construcon
16 9 - 2 10 - 2 10 - 6 3 - 6 load, whichever controls.
22 5 - 5 6 - 5 6 - 6 1 - 10 4. Concrete weights do not include weight of deck.
Versa-Dek®

20 6 - 5 7 - 6 7 - 8 2 - 3 5. Deck profile has been accounted for in determining concrete


5 41 0.375
18 7 - 9 8 - 8 9 - 0 2 - 10 volumes. Deck and support deflections have not been
16 8 - 10 9 - 9 10 - 1 3 - 4
22 included in concrete volumes or weights.
5 - 3 6 - 2 6 - 3 1 - 9
20 6 - 3 7 - 3 7 - 4 2 - 2 6. Cantilever clear spans assume adjacent clear span is at least
5 1/2 46 0.416 3 times longer than the cantilever clear span and no greater
18 7 - 6 8 - 5 8 - 8 2 - 9
16 8 - 6 9 - 5 9 - 9 3 - 3 than spans shown. Bearing width at perimeter support
22 5 - 1 6 - 0 6 - 1 1 - 9 assumed to be 3''minimum. Contact New Millennium
20 6 - 0 7 - 0 7 - 2 2 - 2 otherwise.
6 50 0.458
18 7 - 3 8 - 1 8 - 5 2 - 8
Form Deck

16 8 - 3 9 - 2 9 - 6 3 - 2
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric (in2/ft)
Lightweight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)

22 374 314 267 229 198 172 150 116 87


20 400 378 322 277 239 204 172 125 94 6x6 -
3 1/2 0.028
Typical Fastener Layouts

18 400 400 400 335 276 230 194 141 106 W1.4xW1.4
16 400 400 400 371 305 255 215 156 118
22 400 382 325 279 241 209 183 142 112
20 400 400 392 337 292 255 224 175 137 6x6 -
4 0.028
18 400 400 400 400 383 333 281 204 154 W1.4xW1.4
16 400 400 400 400 400 368 310 226 170
22 400 400 385 330 285 248 218 169 133
20 400 400 400 400 347 303 266 208 165 6x6 -
4 1/2 0.028
18 400 400 400 400 400 398 351 277 213 W1.4xW1.4
16 400 400 400 400 400 400 400 313 235
22 400 400 400 383 331 288 253 197 155
20 400 400 400 400 400 351 309 242 192 6x6 -
5 0.040
18 400 400 400 400 400 400 400 323 259 W2.0xW2.0
16 400 400 400 400 400 400 400 400 314
General Information

22 400 400 400 400 378 329 288 225 177


20 400 400 400 400 400 400 353 277 220 6x6 -
5 1/2 0.040
18 400 400 400 400 400 400 400 369 297 W2.0xW2.0
16 400 400 400 400 400 400 400 400 376
22 400 400 400 400 400 370 325 253 200
20 400 400 400 400 400 400 397 312 249 4x4 -
6 0.042
18 400 400 400 400 400 400 400 400 335 W1.4xW1.4
16 400 400 400 400 400 400 400 400 400
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
62 www.newmill.com/digital-tools
1.5CDR Composite Deck

Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks4 -˝ Type 1.5CDR 3
8
PROPERTIES
Thickness Cover Weight 1 21 ˝
Gage (in) (in) (psf)

22 0.0295 1.63 3 21 ˝
20 0.0358 1.98 ICC-ES APPROVED
36
18 0.0474 2.62 36˝ Coverage REFER TO ESR-3818
16 0.0598 3.30

Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.480 0.175 0.175 0.175 0.157 0.183 0.176 4391 4215 2009 654 1181
20 40 0.582 0.213 0.213 0.213 0.201 0.235 0.224 5624 5375 2428 932 1696
18 40 0.770 0.281 0.281 0.281 0.279 0.315 0.304 7553 7291 3192 1557 2858
16 40 0.971 0.355 0.355 0.355 0.355 0.395 0.390 9454 9332 3996 2381 4396
CONSTRUCTION CLEAR SPANS
Concrete

Composite Deck
Concrete Maximum Construction Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
Depth (in) AISI S100-16.
(psf) Single Double Triple Cantilever (ft3/ft2)
22 5 - 8 6 - 8 6 - 9 1 - 10 2. Web crippling design strengths* and maximum construction
20 6 - 8 7 - 10 7 - 11 2 - 3 spans are based on 1 1/2'' for end bearing and 3'' for interior
3 1/2 36 0.250
18 8 - 1 9 - 1 9 - 4 2 - 11 bearing. Check web crippling if minimums are not met.
16 9 - 2 10 - 2 10 - 7 3 - 6 3. Maximum construction spans are based on ANSI/SDI C-2017
22 5 - 5 6 - 4 6 - 5 1 - 10 Standard for Composite Steel Floor Deck and the following
20 6 - 5 7 - 5 7 - 7 2 - 2
Normal-Weight Concrete (145 pcf)

4 42 0.291 construction loading:


18 7 - 9 8 - 7 8 - 11 2 - 10
● Deck self-weight and concrete weight plus worst-case of
16

Versa-Dek®
8 - 9 9 - 8 10 - 1 3 - 4

Long-Span Composite
22 5 - 2 6 - 1 6 - 2 1 - 9 either a 150 lb.concentrated load or a 20 psf
20 6 - 1 7 - 1 7 - 3 2 - 2 uniform load; or
4 1/2 48 0.333
18 7 - 5 8 - 3 8 - 6 2 - 9 ● Deck self-weight plus a 50 psf uniform construcon
16 8 - 5 9 - 3 9 - 7 3 - 2 load, whichever controls.
22 5 - 0 5 - 10 5 - 11 1 - 9 4. Concrete weights do not include weight of deck.
20 5 - 11 6 - 10 6 - 11 2 - 1

Deep-Dek®
5 54 0.375 5. Deck profile has been accounted for in determining concrete
18 7 - 1 7 - 11 8 - 2 2 - 8 volumes. Deck and support deflections have not been
16 8 - 1 8 - 11 9 - 3 3 - 1
22 included in concrete volumes or weights.
4 - 10 5 - 8 5 - 9 1 - 8
20 5 - 8 6 - 7 6 - 8 2 - 1 6. Cantilever clear spans assume adjacent clear span is at least
5 1/2 60 0.416 3 times longer than the cantilever clear span and no greater
18 6 - 10 7 - 7 7 - 11 2 - 7
16 7 - 10 8 - 7 8 - 11 2 - 11 than spans shown. Bearing width at perimeter support
22 4 - 8 5 - 6 5 - 6 1 - 8 assumed to be 3''minimum. Contact New Millennium
20 5 - 6 6 - 4 6 - 6 2 - 0 otherwise.
6 66 0.458
18 6 - 7 7 - 4 7 - 7 2 - 6

Form Deck
16 7 - 7 8 - 3 8 - 7 2 - 10
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
Normal-Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)

(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric (in2/ft)


22 383 321 271 231 199 172 149 114 87
20 400 388 330 282 243 211 184 142 111 6x6 -
3 1/2 0.028

Typical Fastener Layouts


18 400 400 400 373 323 281 246 179 135 W1.4xW1.4
16 400 400 400 400 386 322 271 198 148
22 400 389 329 281 242 209 182 139 107
20 400 400 400 343 296 257 225 174 136 6x6 -
4 0.028
18 400 400 400 400 393 343 301 235 187 W1.4xW1.4
16 400 400 400 400 400 400 380 286 215
22 400 400 389 332 286 248 215 165 128
20 400 400 400 400 351 305 266 206 162 6x6 -
4 1/2 0.028
18 400 400 400 400 400 400 357 280 222 W1.4xW1.4
16 400 400 400 400 400 400 400 355 285
22 400 400 400 384 331 287 250 192 149
20 400 400 400 400 400 353 309 240 188 6x6 -
5 0.040
18 400 400 400 400 400 400 400 325 259 W2.0xW2.0
General Information
16 400 400 400 400 400 400 400 400 332
22 400 400 400 400 377 327 285 219 170
20 400 400 400 400 400 400 352 274 215 6x6 -
5 1/2 0.040
18 400 400 400 400 400 400 400 371 296 W2.0xW2.0
16 400 400 400 400 400 400 400 400 380
22 400 400 400 400 400 367 320 246 192
20 400 400 400 400 400 400 396 308 243 4x4 -
6 0.042
18 400 400 400 400 400 400 400 400 334 W1.4xW1.4
16 400 400 400 400 400 400 400 400 400
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 63
2.0CD Composite Deck
Table of Contents

LIGHTWEIGHT CONCRETE
Composite Decks - Type 2.0CD
PROPERTIES Optional run-out side lap for screws
Thickness Cover Weight 2˝
Gage (in) (in) (psf) 5˝ 12˝ 2˝ ICC-ES APPROVED
22 0.0295 1.57 5˝
7˝ 12˝ REFER TO ESR-3818
20 0.0358 1.90
36 7˝ 36˝ Coverage
18 0.0474 2.52
Roof Deck

16 0.0598 3.17
36˝ Coverage
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.461 0.341 0.341 0.337 0.328 0.257 0.261 6153 6263 1474 321 617
20 40 0.559 0.419 0.419 0.418 0.410 0.342 0.346 8189 8285 1963 459 882
18 40 0.740 0.555 0.555 0.554 0.554 0.506 0.510 12108 12205 2590 769 1477
16 40 0.932 0.701 0.701 0.699 0.700 0.650 0.651 15572 15583 3255 1176 2260
CONSTRUCTION CLEAR SPANS
Composite Deck

Concrete Maximum Construction Concrete Notes:


Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the AISI S100-16.
Depth (in) 3 2 2. Web crippling design strengths* and maximum construction spans are
(psf) Single Double Triple Cantilever (ft /ft )
based on 2'' for end bearing and 4'' for interior bearing. Check web
22 7 - 9 8 - 11 9 - 3 2 - 8
crippling if minimums are not met.
20 9 - 5 10 - 3 10 - 7 3 - 5
4 27 0.248 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
18 11 - 7 12 - 5 12 - 10 4 - 3
16 12 - 3 13 - 11 14 - 4 4 - 9 Composite Steel Floor Deck and the following construction loading:
22 7 - 5 8 - 9 8 - 10 2 - 7 ● Deck self-weight and concrete weight plus worst-case of either a 150 lb.
20 9 - 0 10 - 1 10 - 5 3 - 4 concentrated load or a 20 psf uniform load; or
4 1/2 32 0.289
Light Weight Concrete (110 pcf)

18 11 - 2 12 - 2 12 - 7 4 - 2 ● Deck self-weight plus a 50 psf uniform construcon load, whichever


Deep-Dek®
Long-Span Composite

16 11 - 10 13 - 8 13 - 10 4 - 7 controls.
22 7 - 2 8 - 4 8 - 6 2 - 7 4. Concrete weights do not include weight of deck.
20 8 - 7 9 - 8 10 - 0 3 - 3 5. Deck profile has been accounted for in determining concrete
5 36 0.331
18 10 - 9 11 - 8 12 - 1 4 - 0 volumes. Deck and support deflections have not been included in
16 11 - 5 13 - 2 13 - 5 4 - 5 concrete volumes or weights.
22 6 - 10 7 - 10 8 - 2 2 - 6 6. Cantilever clear spans assume adjacent clear span is at least 3 times
Versa-Dek®

20 8 - 3 9 - 3 9 - 7 3 - 1 longer than the cantilever clear span and no greater than spans
5 1/2 41 0.373
18 10 - 4 11 - 3 11 - 8 3 - 10 published above. Bearing width at perimeter support assumed to be 4''
16 11 - 1 12 - 8 13 - 1 4 - 4 minimum. Contact New Millennium otherwise.
22 6 - 8 7 - 4 7 - 10 2 - 5
20 8 - 0 9 - 0 9 - 3 3 - 0
6 46 0.414
18 10 - 0 10 - 10 11 - 3 3 - 9
16 10 - 9 12 - 3 12 - 8 4 - 2
22 6 - 5 6 - 10 7 - 7 2 - 5
20 7 - 9 8 - 8 8 - 11 2 - 11
6 1/2 50 0.456
Form Deck

18 9 - 8 10 - 6 10 - 10 3 - 7
16 10 - 5 11 - 10 12 - 3 4 - 1
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 7 - 0 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 Fabric (in2/ft)
Light Weight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)

22 237 175 151 132 101 79 62 48 38


20 286 212 184 161 125 98 78 62 50 6x6 -
Typical Fastener Layouts

4 0.028
18 372 277 242 213 167 127 97 77 61 W1.4xW1.4
16 400 309 271 238 187 140 108 85 68
22 287 212 184 161 124 97 76 60 47
20 347 257 224 196 153 120 96 77 61 6x6 -
4 1/2 0.028
18 400 337 295 259 203 162 131 106 85 W1.4xW1.4
16 400 376 329 290 228 183 148 118 94
22 340 252 219 191 147 115 91 72 57
20 400 306 266 233 182 144 115 92 74 6x6 -
5 0.028
18 400 400 351 308 242 194 156 128 105 W1.4xW1.4
16 400 400 392 346 272 218 177 145 120
22 396 293 255 222 172 135 107 84 67
20 400 356 310 272 212 168 134 108 87 6x6 -
5 1/2 0.040
18 400 400 400 360 283 227 183 150 123 W2.0xW2.0
General Information

16 400 400 400 400 319 256 208 171 141


22 400 335 291 255 198 155 123 98 78
20 400 400 356 312 244 193 155 125 101 6x6 -
6 0.040
18 400 400 400 400 325 261 211 173 143 W2.0xW2.0
16 400 400 400 400 367 295 240 197 163
22 400 378 329 288 223 176 139 111 89
20 400 400 400 353 276 219 176 142 115 6x6 -
6 1/2 0.040
18 400 400 400 400 369 296 240 197 162 W2.0xW2.0
16 400 400 400 400 400 335 273 225 186
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
64 www.newmill.com/digital-tools
2.0CD Composite Deck

Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 2.0CD
PROPERTIES Optional run-out side lap for screws
Thickness Cover Weight 2˝
Gage (in) (in) (psf) 5˝ 2˝
12˝ ICC-ES APPROVED
22 0.0295 1.57

7˝ 12˝ REFER TO ESR-3818
20 0.0358 1.90
36 7˝ 36˝ Coverage
18 0.0474 2.52

Roof Deck
16 0.0598 3.17
36˝ Coverage
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.461 0.341 0.341 0.337 0.328 0.257 0.261 6153 6263 1474 321 617
20 40 0.559 0.419 0.419 0.418 0.410 0.342 0.346 8189 8285 1963 459 882
18 40 0.740 0.555 0.555 0.554 0.554 0.506 0.510 12108 12205 2590 769 1477
16 40 0.932 0.701 0.701 0.699 0.700 0.650 0.651 15572 15583 3255 1176 2260
CONSTRUCTION CLEAR SPANS

Composite Deck
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the AISI S100-16.
Depth (in) 3 2 2. Web crippling design strengths* and maximum construction spans are
(psf) Single Double Triple Cantilever (ft /ft )
based on 2'' for end bearing and 4'' for interior bearing. Check web
22 7 - 2 8 - 5 8 - 6 2 - 7
crippling if minimums are not met.
20 8 - 8 9 - 8 10 - 0 3 - 3
4 36 0.248 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
18 10 - 9 11 - 9 12 - 2 4 - 0
16 11 - 6 13 - 2 13 - 6 4 - 6 Composite Steel Floor Deck and the following construction loading:
22 6 - 10 7 - 9 8 - 1 2 - 6 ● Deck self-weight and concrete weight plus worst-case of either a 150 lb.
20 8 - 3 9 - 3 9 - 7 3 - 1 concentrated load or a 20 psf uniform load; or
Normal Weight Concrete (145 pcf)

4 1/2 42 0.289
18 10 - 3 11 - 2 11 - 7 3 - 10 ● Deck self-weight plus a 50 psf uniform construcon load, whichever

Versa-Dek®
Long-Span Composite
16 11 - 0 12 - 7 13 - 0 4 - 4 controls.
22 6 - 6 7 - 1 7 - 9 2 - 5 4. Concrete weights do not include weight of deck.
20 7 - 10 8 - 9 9 - 1 3 - 0 5. Deck profile has been accounted for in determining concrete
5 48 0.331
18 9 - 10 10 - 8 11 - 0 3 - 8 volumes. Deck and support deflections have not been included in
16 10 - 7 12 - 0 12 - 5 4 - 1 concrete volumes or weights.
22 6 - 1 6 - 6 7 - 4 2 - 4 6. Cantilever clear spans assume adjacent clear span is at least 3 times

Deep-Dek®
20 7 - 6 8 - 5 8 - 9 2 - 11 longer than the cantilever clear span and no greater than spans
5 1/2 54 0.373
18 9 - 6 10 - 3 10 - 7 3 - 6 published above. Bearing width at perimeter support assumed to be 4''
16 10 - 2 11 - 6 11 - 11 3 - 11 minimum. Contact New Millennium otherwise.
22 5 - 6 6 - 0 6 - 10 2 - 3
20 7 - 3 8 - 1 8 - 5 2 - 9
6 60 0.414
18 9 - 2 9 - 10 10 - 2 3 - 4
16 9 - 10 11 - 1 11 - 6 3 - 10
22 5 - 0 5 - 6 6 - 3 2 - 1
20 7 - 0 7 - 10 8 - 1 2 - 8
6 1/2 66 0.456

Form Deck
18 8 - 10 9 - 6 9 - 10 3 - 3
16 9 - 7 10 - 8 11 - 1 3 - 8
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in2/ft)
Normal Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)

(in) 7 - 0 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 Fabric
22 241 176 151 131 99 75 57 43 32
20 293 215 187 162 124 96 75 58 45 6x6 -

Typical Fastener Layouts


4 0.028
18 385 286 249 218 169 133 106 84 68 W1.4xW1.4
16 400 322 280 246 192 152 121 98 79
22 291 213 184 159 121 92 70 54 40
20 355 261 226 197 151 118 92 72 56 6x6 -
4 1/2 0.028
18 400 347 302 265 206 163 130 104 83 W1.4xW1.4
16 400 391 341 299 234 185 149 120 97
22 345 252 218 189 144 110 85 65 49
20 400 310 269 234 180 140 110 86 68 6x6 -
5 0.028
18 400 400 359 315 245 194 155 124 100 W1.4xW1.4
16 400 400 400 356 278 221 178 144 117
22 400 293 253 220 167 129 99 76 58
20 400 360 312 272 210 164 129 101 80 6x6 -
5 1/2 0.040
18 400 400 400 366 286 227 181 146 118 W2.0xW2.0
General Information
16 400 400 400 400 325 259 208 169 138
22 400 335 289 251 192 148 115 88 68
20 400 400 357 312 241 188 148 117 93 6x6 -
6 0.040
18 400 400 400 400 328 260 209 168 137 W2.0xW2.0
16 400 400 400 400 373 298 240 195 159
22 400 377 326 284 217 168 130 101 78
20 400 400 400 352 272 213 168 133 106 6x6 -
6 1/2 0.040
18 400 400 400 400 371 295 237 191 156 W2.0xW2.0
16 400 400 400 400 400 337 272 222 182
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 65
3.0CD Composite Deck
Table of Contents

LIGHTWEIGHT CONCRETE
Composite Decks - Type 3.0CD
Optional run-out side lap for screws
PROPERTIES
Thickness Cover Weight 3˝
Gage (in) (in) (psf) ˝ ICC-ES APPROVED
22 0.0295 1.71
20 0.0358 2.07 ˝ REFER TO ESR-3818
36
18 0.0474 2.74
36˝ Coverage
Roof Deck

16 0.0598 3.45
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.502 0.770 0.770 0.764 0.750 0.407 0.424 9749 10151 1416 336 677
20 40 0.609 0.946 0.946 0.945 0.934 0.537 0.556 12871 13319 2227 482 967
18 40 0.805 1.253 1.253 1.252 1.253 0.794 0.802 19016 19213 3895 811 1615
16 40 1.015 1.580 1.580 1.579 1.579 1.012 1.013 24245 24264 4901 1245 2466
CONSTRUCTION CLEAR SPANS
Composite Deck

Concrete Maximum Construction Concrete Notes:


Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the AISI S100-16.
Depth (in) 2. Web crippling design strengths* and maximum construction spans are
(psf) Single Double Triple Cantilever (ft3/ft2)
based on 2 1/2'' for end bearing and 5'' for interior bearing. Check web
22 10 - 1 10 - 0 11 - 5 3 - 9
crippling if minimums are not met.
20 12 - 0 12 - 8 13 - 2 4 - 4
5 32 0.292 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
18 13 - 8 15 - 3 15 - 9 5 - 3
16 14 - 5 17 - 0 16 - 11 5 - 8 Composite Steel Floor Deck and the following construction loading:
22 9 - 8 9 - 3 10 - 6 3 - 6 ● Deck self-weight and concrete weight plus worst-case of either a 150 lb.
20 11 - 6 12 - 2 12 - 7 4 - 2 concentrated load or a 20 psf uniform load; or
5 1/2 37 0.333
Light Weight Concrete (110 pcf)

18 13 - 3 14 - 8 15 - 2 5 - 0 ● Deck self-weight plus a 50 psf uniform construcon load, whichever


Deep-Dek®
Long-Span Composite

16 14 - 0 16 - 4 16 - 5 5 - 5 controls.
22 8 - 7 8 - 7 9 - 9 3 - 3 4. Concrete weights do not include weight of deck.
20 11 - 0 11 - 9 12 - 2 4 - 0 5. Deck profile has been accounted for in determining concrete
6 41 0.375
18 12 - 11 14 - 1 14 - 7 4 - 10 volumes. Deck and support deflections have not been included in
16 13 - 7 15 - 9 16 - 0 5 - 4 concrete volumes or weights.
22 7 - 9 8 - 0 9 - 1 3 - 0
Versa-Dek®

6. Cantilever clear spans assume adjacent clear span is at least 3 times


20 10 - 7 11 - 4 11 - 8 3 - 10 longer than the cantilever clear span and no greater than spans
6 1/2 46 0.417
18 12 - 7 13 - 7 14 - 1 4 - 8 published above. Bearing width at perimeter support assumed to be 5''
16 13 - 3 15 - 3 15 - 7 5 - 2 minimum. Contact New Millennium otherwise.
22 7 - 1 7 - 6 8 - 6 2 - 10
20 10 - 2 10 - 8 11 - 4 3 - 9
7 50 0.458
18 12 - 4 13 - 2 13 - 8 4 - 6
16 13 - 0 14 - 9 15 - 3 5 - 1
22 6 - 6 7 - 0 8 - 0 2 - 8
20 9 - 10 10 - 0 11 - 0 3 - 8
Form Deck

7 1/2 55 0.500
18 12 - 1 12 - 9 13 - 2 4 - 4
16 12 - 9 14 - 4 14 - 10 4 - 11
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0 16 - 0 Fabric (in2/ft)
Light Weight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)

22 228 173 133 104 82 65 52 41 32


6x6 -
Typical Fastener Layouts

20 276 211 164 130 104 83 67 54 43


5 0.028
18 362 278 219 175 141 115 95 78 64 W1.4xW1.4
16 400 347 274 221 180 148 121 98 81
22 266 202 156 123 97 77 61 48 38
20 322 247 192 152 122 98 79 64 52 6x6 -
5 1/2 0.028
18 400 325 256 205 166 135 111 92 76 W1.4xW1.4
16 400 400 321 258 210 173 144 120 101
22 307 233 181 142 112 89 71 57 44
20 372 285 222 176 141 114 92 75 61 6x6 -
6 0.028
18 400 376 296 237 192 157 129 107 89 W1.4xW1.4
16 400 400 371 299 244 201 167 140 118
22 349 266 207 162 129 103 82 65 52
20 400 325 254 202 162 131 106 86 70 6x6 -
6 1/2 0.040
18 400 400 338 271 220 180 149 123 102 W2.0xW2.0
General Information

16 400 400 400 341 279 230 192 161 135


22 394 300 233 184 146 117 93 75 59
20 400 366 287 228 183 148 121 98 80 6x6 -
7 0.040
18 400 400 382 306 249 204 169 140 117 W2.0xW2.0
16 400 400 400 386 316 261 218 183 154
22 400 335 261 205 164 131 105 84 67
20 400 400 321 255 205 166 136 111 90 4x4 -
7 1/2 0.042
18 400 400 400 343 279 229 190 158 132 W1.4xW1.4
16 400 400 400 400 354 293 245 206 174
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
Code of Standard Practice

8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
66 www.newmill.com/digital-tools
3.0CD Composite Deck

Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 3.0CD
Optional run-out side lap for screws
PROPERTIES
Thickness Cover Weight 3˝
Gage (in) (in) (psf) ˝ ICC-ES APPROVED
22 0.0295 1.71
20 0.0358 2.07 ˝ REFER TO ESR-3818
36
18 0.0474 2.74
36˝ Coverage

Roof Deck
16 0.0598 3.45
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.502 0.770 0.770 0.764 0.750 0.407 0.424 9749 10151 1416 336 677
20 40 0.609 0.946 0.946 0.945 0.934 0.537 0.556 12871 13319 2227 482 967
18 40 0.805 1.253 1.253 1.252 1.253 0.794 0.802 19016 19213 3895 811 1615
16 40 1.015 1.580 1.580 1.579 1.579 1.012 1.013 24245 24264 4901 1245 2466
CONSTRUCTION CLEAR SPANS

Composite Deck
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the AISI S100-16.
Depth (in) 2. Web crippling design strengths* and maximum construction spans are
(psf) Single Double Triple Cantilever (ft3/ft2)
based on 2 1/2'' for end bearing and 5'' for interior bearing. Check web
22 8 - 5 8 - 5 9 - 7 3 - 2
crippling if minimums are not met.
20 10 - 11 11 - 7 12 - 0 4 - 0
5 42 0.292 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
18 12 - 10 14 - 0 14 - 6 4 - 10
16 13 - 6 15 - 8 15 - 10 5 - 3 Composite Steel Floor Deck and the following construction loading:
22 7 - 5 7 - 8 8 - 9 2 - 11 ● Deck self-weight and concrete weight plus worst-case of either a 150 lb.
20 10 - 4 10 - 11 11 - 6 3 - 10 concentrated load or a 20 psf uniform load; or
Normal Weight Concrete (145 pcf)

5 1/2 48 0.333
18 12 - 5 13 - 4 13 - 10 4 - 7 ● Deck self-weight plus a 50 psf uniform construcon load, whichever

Versa-Dek®
Long-Span Composite
16 13 - 1 15 - 0 15 - 5 5 - 1 controls.
22 6 - 7 7 - 1 8 - 1 2 - 8 4. Concrete weights do not include weight of deck.
20 9 - 11 10 - 1 11 - 0 3 - 8 5. Deck profile has been accounted for in determining concrete
6 54 0.375
18 12 - 1 12 - 10 13 - 3 4 - 5 volumes. Deck and support deflections have not been included in
16 12 - 9 14 - 4 14 - 10 4 - 11 concrete volumes or weights.
22 5 - 11 6 - 7 7 - 5 2 - 5 6. Cantilever clear spans assume adjacent clear span is at least 3 times

Deep-Dek®
20 9 - 6 9 - 4 10 - 7 3 - 6 longer than the cantilever clear span and no greater than spans
6 1/2 60 0.417
18 11 - 9 12 - 4 12 - 9 4 - 3 published above. Bearing width at perimeter support assumed to be 5''
16 12 - 5 13 - 10 14 - 4 4 - 9 minimum. Contact New Millennium otherwise.
22 5 - 5 6 - 1 6 - 9 2 - 3
20 9 - 2 8 - 8 9 - 11 3 - 3
7 66 0.458
18 11 - 6 11 - 11 12 - 4 4 - 1
16 12 - 2 13 - 4 13 - 10 4 - 7
22 5 - 0 5 - 8 6 - 3 2 - 1
20 8 - 10 8 - 2 9 - 3 3 - 1

Form Deck
7 1/2 72 0.500
18 11 - 1 11 - 6 11 - 11 3 - 11
16 11 - 11 12 - 11 13 - 5 4 - 5
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in2/ft)
Normal Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)

(in) 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0 16 - 0 Fabric
22 229 171 130 100 77 59 45 34 24
6x6 -

Typical Fastener Layouts


20 280 212 163 127 100 79 62 48 37
5 0.028
18 372 284 222 175 140 113 91 73 59 W1.4xW1.4
16 400 358 281 225 181 148 121 100 82
22 267 201 153 118 91 70 54 40 29
20 327 248 191 149 117 93 73 57 44 6x6 -
5 1/2 0.028
18 400 332 259 206 165 133 107 87 70 W1.4xW1.4
16 400 400 329 263 213 174 143 118 97
22 308 232 177 136 106 82 63 47 35
20 377 286 221 173 136 108 85 67 52 6x6 -
6 0.028
18 400 383 300 238 191 154 125 101 82 W1.4xW1.4
16 400 400 380 304 246 201 166 137 113
22 350 264 202 156 121 94 73 55 41
20 400 326 252 198 156 124 98 77 60 6x6 -
6 1/2 0.040
18 400 400 342 272 218 177 144 117 95 W2.0xW2.0
General Information
16 400 400 400 348 282 231 190 157 131
22 394 297 228 176 137 107 83 63 47
20 400 368 285 223 177 140 112 88 69 6x6 -
7 0.040
18 400 400 386 307 247 200 163 133 109 W2.0xW2.0
16 400 400 400 393 319 261 216 179 149
22 400 332 254 197 154 120 93 72 54
20 400 400 318 250 198 158 126 100 79 4x4 -
7 1/2 0.042
18 400 400 400 343 276 224 183 150 122 W1.4xW1.4
16 400 400 400 400 357 293 242 201 167
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
Code of Standard Practice

8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 67
1.5CFDC Composite Floor Deck Cellular
Table of Contents

LIGHTWEIGHT CONCRETE
Composite Decks - Type 1.5CFDC Cellular
PROPERTIES 6˝ 2 21 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 1 21 ˝
20/20 0.0358/0.0358 3.49 1 85 ˝
20/18 0.0358/0.0474
24.5
4.01 24 21 ˝ Coverage
18/20 0.0474/0.0358 4.09
Roof Deck

18/18 0.0474/0.0474 4.61


ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 50 2.092 0.395 0.395 0.376 0.323 0.292 0.380 8750 11372 2871 1146 2027
20/18 50 2.406 0.437 0.437 0.415 0.394 0.309 0.437 9237 13087 2871 1146 2027
18/20 50 2.453 0.505 0.505 0.494 0.393 0.422 0.445 12623 13324 3783 1913 3433
18/18 50 2.767 0.558 0.558 0.546 0.465 0.441 0.552 13198 16521 3783 1913 3433
CONSTRUCTION CLEAR SPANS
Composite Deck

Concrete Maximum Construction Concrete Notes:


Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) 3 2 accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft /ft )
2. Web crippling design strengths* and maximum construction spans are
20/20 10 - 2 11 - 10 12 - 0 4 - 0
based on 1 1/2'' for end bearing and 3'' for interior bearing. Check web
20/18 10 - 6 12 - 2 12 - 3 4 - 1
3 1/2 23 0.211 crippling if minimums are not met.
18/20 11 - 7 12 - 9 13 - 3 4 - 5
18/18 11 - 10 14 - 2 13 - 10 4 - 8 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
20/20 9 - 8 11 - 4 11 - 5 3 - 9 Composite Steel Floor Deck and the following construction loading:
20/18 9 - 11 11 - 8 11 - 9 3 - 11 ● Deck self-weight and concrete weight plus worst-case of either a 150
4 28 0.252
18/20 11 - 1 12 - 9 13 - 1 4 - 4 lb. concentrated load or a 20 psf uniform load; or
Lightweight Concrete (110 pcf)
Deep-Dek®
Long-Span Composite

18/18 11 - 4 14 - 2 13 - 4 4 - 8 ● Deck self-weight plus a 50 psf uniform construcon load, whichever


20/20 9 - 2 10 - 9 10 - 11 3 - 7 controls.
20/18 9 - 6 11 - 1 11 - 3 3 - 9 4. Concrete weights do not include weight of deck.
4 1/2 32 0.294
18/20 10 - 7 12 - 6 12 - 7 4 - 2 5. Deck profile has been accounted for in determining concrete
18/18 10 - 11 13 - 9 12 - 11 4 - 7 volumes. Deck and support deflections have not been included in
20/20 8 - 10 10 - 4 10 - 5 3 - 5 concrete volumes or weights.
Versa-Dek®

20/18 9 - 1 10 - 7 10 - 9 3 - 7 6. Cantilever clear spans assume adjacent clear span is at least 3 times
5 37 0.336
18/20 10 - 2 12 - 0 12 - 3 4 - 1 longer than the cantilever clear span and no greater than spans
18/18 10 - 6 13 - 2 12 - 6 4 - 4 published above. Bearing width at perimeter support assumed to be 3''
20/20 8 - 6 9 - 11 10 - 0 3 - 4 minimum. Contact New Millennium otherwise.
20/18 8 - 9 10 - 3 10 - 4 3 - 5
5 1/2 42 0.377
18/20 9 - 10 11 - 7 11 - 11 3 - 11
18/18 10 - 2 12 - 8 12 - 2 4 - 2
20/20 8 - 2 9 - 7 9 - 8 3 - 2
20/18 8 - 5 9 - 10 9 - 11 3 - 3
6 46 0.419
Form Deck

18/20 9 - 6 11 - 3 11 - 7 3 - 10
18/18 9 - 10 12 - 2 11 - 11 4 - 0
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric (in2/ft)
Lightweight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)

20/20 243 204 172 146 125 108 93 71 54


20/18 243 203 171 146 125 107 93 70 53 6x6 -
Typical Fastener Layouts

3 1/2 0.028
18/20 229 191 161 137 117 100 87 65 49 W1.4xW1.4
18/18 229 191 161 136 116 100 86 64 48
20/20 312 261 221 189 162 140 121 92 71
20/18 312 261 221 188 161 139 121 92 70 6x6 -
4 0.028
18/20 295 247 208 177 152 131 114 86 65 W1.4xW1.4
18/18 295 246 208 177 152 131 113 85 65
20/20 385 323 273 233 201 174 151 116 89
20/18 384 322 273 233 200 173 151 115 89 6x6 -
4 1/2 0.028
18/20 366 306 259 221 190 164 142 108 83 W1.4xW1.4
18/18 365 306 259 220 189 163 142 108 83
20/20 400 386 328 280 241 209 182 140 109
20/18 400 386 327 280 241 209 182 139 108 6x6 -
5 0.040
18/20 400 368 312 266 229 198 172 132 102 W2.0xW2.0
General Information

18/18 400 368 311 266 229 198 172 131 101
20/20 400 400 383 328 283 246 214 165 128
20/18 400 400 383 328 282 245 214 164 128 6x6 -
5 1/2 0.040
18/20 400 400 366 313 270 234 204 156 121 W2.0xW2.0
18/18 400 400 366 313 269 233 203 156 121
20/20 400 400 400 377 325 283 247 190 149
20/18 400 400 400 377 325 282 246 190 148 4x4 -
6 0.042
18/20 400 400 400 361 312 270 236 181 141 W1.4xW1.4
18/18 400 400 400 361 311 270 235 181 141
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
68 www.newmill.com/digital-tools
1.5CFDC Composite Floor Deck Cellular

Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 1.5CFDC Cellular
PROPERTIES 6˝ 2 21 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 1 21 ˝
18/16 0.0474/0.0598 5.17 1 85 ˝
16/18 0.0598/0.0474 24.5 5.25 24 21 ˝ Coverage
16/16 0.0598/0.0598 5.81

Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 3.102 0.607 0.607 0.594 0.554 0.458 0.583 13700 17444 3783 1913 3433
16/18 40 3.151 0.679 0.679 0.678 0.555 0.628 0.645 15035 15445 3798 2338 4234
16/16 40 3.486 0.739 0.739 0.738 0.655 0.648 0.712 15519 17042 3798 2338 4234

Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) 3 2 accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft /ft )
2. Web crippling design strengths* and maximum construction spans are
18/16 12 - 0 14 - 6 14 - 1 4 - 10
based on 1 1/2'' for end bearing and 3'' for interior bearing. Check web

Versa-Dek®
3 1/2 16/18 23 0.211

Long-Span Composite
12 - 4 13 - 7 14 - 1 4 - 8
crippling if minimums are not met.
16/16 12 - 7 14 - 3 14 - 9 4 - 11
3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
18/16 11 - 7 14 - 5 13 - 7 4 - 9
Lightweight Concrete (110 pcf)

Composite Steel Floor Deck and the following construction loading:


4 16/18 28 11 - 11 13 - 7 13 - 11 4 - 7 0.252
● Deck self-weight and concrete weight plus worst-case of either a 150
16/16 12 - 1 14 - 3 14 - 2 4 - 9
lb. concentrated load or a 20 psf uniform load; or
18/16 11 - 2 13 - 11 13 - 1 4 - 7

Deep-Dek®
● Deck self-weight plus a 50 psf uniform construcon load, whichever
4 1/2 16/18 32 11 - 6 13 - 4 13 - 6 4 - 6 0.294
controls.
16/16 11 - 9 13 - 11 13 - 9 4 - 7
4. Concrete weights do not include weight of deck.
18/16 10 - 9 13 - 5 12 - 9 4 - 5
5. Deck profile has been accounted for in determining concrete
5 16/18 37 11 - 2 12 - 10 13 - 1 4 - 4 0.336
volumes. Deck and support deflections have not been included in
16/16 11 - 5 13 - 5 13 - 4 4 - 5
concrete volumes or weights.
18/16 10 - 5 12 - 11 12 - 5 4 - 3
5 1/2 16/18 42 0.377 6. Cantilever clear spans assume adjacent clear span is at least 3 times
10 - 9 12 - 5 12 - 9 4 - 3
16/16 longer than the cantilever clear span and no greater than spans
11 - 1 12 - 11 13 - 0 4 - 4
18/16 published above. Bearing width at perimeter support assumed to be 3''
10 - 1 12 - 5 12 - 2 4 - 1

Form Deck
6 16/18 46 0.419 minimum. Contact New Millennium otherwise.
10 - 5 12 - 0 12 - 4 4 - 1
16/16 10 - 9 12 - 6 12 - 9 4 - 3

SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire

Typical Fastener Layouts


Depth Gage Clear Span (ft - in) Welded Wire Area
LW Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)

(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric (in2/ft)


18/16 228 190 160 136 116 99 86 64 48 6x6 -
3 1/2 16/18 167 138 115 97 81 69 58 42 30 0.028
16/16 166 137 114 96 81 68 58 41 29 W1.4xW1.4
18/16 294 246 207 176 151 130 112 85 64 6x6 -
4 16/18 217 180 151 127 108 92 78 57 41 0.028
16/16 216 179 150 126 107 91 78 56 41 W1.4xW1.4
18/16 365 305 258 220 189 163 141 107 82 6x6 -
4 1/2 16/18 271 225 189 160 136 116 99 73 54 0.028
16/16 270 225 188 159 135 116 99 73 54 W1.4xW1.4
18/16 400 367 311 265 228 197 171 131 101
General Information
6x6 -
5 16/18 327 273 229 194 166 142 122 91 68 0.040
16/16 327 272 229 194 165 141 122 90 67 W2.0xW2.0
18/16 400 400 365 312 269 233 203 155 120 6x6 -
5 1/2 16/18 386 322 271 230 197 169 145 109 82 0.040
16/16 385 321 270 230 196 168 145 108 81 W2.0xW2.0
18/16 400 400 400 360 310 269 235 180 140 4x4 -
6 16/18 400 372 314 267 228 196 170 128 97 0.042
16/16 400 372 313 266 228 196 169 127 96 W1.4xW1.4

Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 69
1.5CFDC Composite Floor Deck Cellular
Table of Contents

NORMAL-WEIGHT CONCRETE
Composite Decks - Type 1.5CFDC Cellular
PROPERTIES 6˝ 2 21 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 1 21 ˝
20/20 0.0358/0.0358 3.49 1 85 ˝
20/18 0.0358/0.0474
24.5
4.01 24 21 ˝ Coverage
18/20 0.0474/0.0358 4.09
Roof Deck

18/18 0.0474/0.0474 4.61


ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 50 2.092 0.395 0.395 0.376 0.323 0.292 0.380 8750 11372 2871 1146 2027
20/18 50 2.406 0.437 0.437 0.415 0.394 0.309 0.437 9237 13087 2871 1146 2027
18/20 50 2.453 0.505 0.505 0.494 0.393 0.422 0.445 12623 13324 3783 1913 3433
18/18 50 2.767 0.558 0.558 0.546 0.465 0.441 0.552 13198 16521 3783 1913 3433
CONSTRUCTION CLEAR SPANS
Composite Deck

Concrete Maximum Construction Concrete Notes:


Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) 3 2 accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft /ft )
2. Web crippling design strengths* and maximum construction spans are
20/20 9 - 4 11 - 0 11 - 1 3 - 8
based on 1 1/2'' for end bearing and 3'' for interior bearing. Check web
20/18 9 - 8 11 - 3 11 - 5 3 - 9
3 1/2 31 0.211 crippling if minimums are not met.
18/20 10 - 10 12 - 9 12 - 9 4 - 3
18/18 11 - 1 13 - 11 13 - 1 4 - 7 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
20/20 8 - 10 10 - 4 10 - 5 3 - 5 Composite Steel Floor Deck and the following construction loading:
20/18 9 - 1 10 - 8 10 - 9 3 - 7 ● Deck self-weight and concrete weight plus worst-case of either a 150
Normal-Weight Concrete (145 pcf)

4 37 0.252
18/20 10 - 3 12 - 1 12 - 3 4 - 1 lb. concentrated load or a 20 psf uniform load; or
Deep-Dek®
Long-Span Composite

18/18 10 - 6 13 - 3 12 - 7 4 - 5 ● Deck self-weight plus a 50 psf uniform construcon load, whichever


20/20 8 - 5 9 - 10 9 - 11 3 - 3 controls.
20/18 8 - 8 10 - 1 10 - 3 3 - 5 4. Concrete weights do not include weight of deck.
4 1/2 43 0.294
18/20 9 - 9 11 - 6 11 - 10 3 - 11 5. Deck profile has been accounted for in determining concrete
18/18 10 - 1 12 - 7 12 - 1 4 - 2 volumes. Deck and support deflections have not been included in
20/20 8 - 1 9 - 4 9 - 6 3 - 2 concrete volumes or weights.
Versa-Dek®

20/18 8 - 3 9 - 7 9 - 9 3 - 3 6. Cantilever clear spans assume adjacent clear span is at least 3 times
5 49 0.336
18/20 9 - 5 11 - 0 11 - 5 3 - 9 longer than the cantilever clear span and no greater than spans
18/18 9 - 8 12 - 0 11 - 9 4 - 0 published above. Bearing width at perimeter support assumed to be 3''
20/20 7 - 9 9 - 0 9 - 1 3 - 0 minimum. Contact New Millennium otherwise.
20/18 7 - 11 8 - 7 9 - 4 3 - 1
5 1/2 55 0.377
18/20 9 - 1 10 - 7 10 - 11 3 - 7
18/18 9 - 4 11 - 5 11 - 5 3 - 9
20/20 7 - 5 8 - 4 8 - 9 2 - 11
20/18 7 - 8 7 - 9 8 - 10 2 - 11
6 61 0.419
Form Deck

18/20 8 - 9 10 - 2 10 - 6 3 - 6
18/18 9 - 0 11 - 0 11 - 1 3 - 8
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in2/ft)
Normal-Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)

(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric
20/20 253 211 177 150 127 109 94 69 51
20/18 253 210 176 149 127 109 93 69 51 6x6 -
Typical Fastener Layouts

3 1/2 0.028
18/20 240 199 167 141 120 102 87 64 47 W1.4xW1.4
18/18 239 199 166 141 119 102 87 64 47
20/20 323 269 227 192 164 141 121 91 68
20/18 322 269 226 192 164 140 121 90 67 6x6 -
4 0.028
18/20 308 256 215 182 155 133 114 85 63 W1.4xW1.4
18/18 307 256 215 182 155 132 114 84 62
20/20 397 331 279 237 203 174 151 113 86
20/18 396 331 279 237 202 174 150 113 85 6x6 -
4 1/2 0.028
18/20 379 316 266 226 193 166 143 107 80 W1.4xW1.4
18/18 379 316 266 225 192 165 142 106 80
20/20 400 395 333 284 243 209 181 137 104
20/18 400 394 333 283 242 209 181 136 103 6x6 -
5 0.040
18/20 400 379 319 271 232 200 172 130 98 W2.0xW2.0
General Information

18/18 400 378 319 271 232 199 172 129 97


20/20 400 400 389 331 284 245 212 161 123
20/18 400 400 388 331 284 245 212 160 122 6x6 -
5 1/2 0.040
18/20 400 400 374 318 272 235 203 153 116 W2.0xW2.0
18/18 400 400 373 318 272 234 202 153 116
20/20 400 400 400 380 326 282 244 186 142
20/18 400 400 400 379 326 281 244 185 142 4x4 -
6 0.042
18/20 400 400 400 366 314 270 234 177 135 W1.4xW1.4
18/18 400 400 400 365 313 270 234 177 135
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
70 www.newmill.com/digital-tools
1.5CFDC Composite Floor Deck Cellular

Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 1.5CFDC Cellular
PROPERTIES 6˝ 2 21 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 1 21 ˝
18/16 0.0474/0.0598 5.17 1 85 ˝
16/18 0.0598/0.0474 24.5 5.25 24 21 ˝ Coverage
16/16 0.0598/0.0598 5.81

Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 3.102 0.607 0.607 0.594 0.554 0.458 0.583 13700 17444 3783 1913 3433
16/18 40 3.151 0.679 0.679 0.678 0.555 0.628 0.645 15035 15445 3798 2338 4234
16/16 40 3.486 0.739 0.739 0.738 0.655 0.648 0.712 15519 17042 3798 2338 4234

Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) 3 2 accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft /ft )
2. Web crippling design strengths* and maximum construction spans are
18/16 11 - 4 14 - 2 13 - 3 4 - 8
based on 1 1/2'' for end bearing and 3'' for interior bearing. Check web

Versa-Dek®
Long-Span Composite
3 1/2 16/18 31 11 - 8 13 - 7 13 - 8 4 - 6 0.211
crippling if minimums are not met.
16/16 11 - 10 14 - 2 13 - 11 4 - 8
Normal-Weight Concrete (145 pcf)

3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for


18/16 10 - 9 13 - 6 12 - 9 4 - 6
Composite Steel Floor Deck and the following construction loading:
4 16/18 37 11 - 2 12 - 10 13 - 2 4 - 4 0.252
● Deck self-weight and concrete weight plus worst-case of either a 150
16/16 11 - 5 13 - 5 13 - 4 4 - 5
lb. concentrated load or a 20 psf uniform load; or
18/16 10 - 4 12 - 9 12 - 4 4 - 3

Deep-Dek®
● Deck self-weight plus a 50 psf uniform construcon load, whichever
4 1/2 16/18 43 10 - 8 12 - 3 12 - 8 4 - 2 0.294
controls.
16/16 11 - 0 12 - 10 12 - 11 4 - 3
4. Concrete weights do not include weight of deck.
18/16 9 - 11 12 - 2 12 - 0 4 - 0
5. Deck profile has been accounted for in determining concrete
5 16/18 49 10 - 3 11 - 9 12 - 2 4 - 0 0.336
volumes. Deck and support deflections have not been included in
16/16 10 - 7 12 - 3 12 - 7 4 - 2
concrete volumes or weights.
18/16 9 - 7 11 - 8 11 - 8 3 - 10
5 1/2 16/18 55 0.377 6. Cantilever clear spans assume adjacent clear span is at least 3 times
9 - 11 11 - 3 11 - 8 3 - 10
16/16 longer than the cantilever clear span and no greater than spans
10 - 2 11 - 10 12 - 3 4 - 1
18/16 published above. Bearing width at perimeter support assumed to be 3''
9 - 3 11 - 3 11 - 4 3 - 9

Form Deck
6 16/18 61 0.419 minimum. Contact New Millennium otherwise.
9 - 7 10 - 11 11 - 3 3 - 9
16/16 9 - 10 11 - 5 11 - 9 3 - 11

SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire

Typical Fastener Layouts


Depth Gage Clear Span (ft - in) Welded Wire Area
NW Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)

(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric (in2/ft)


18/16 239 198 166 140 119 101 86 63 46 6x6 -
3 1/2 16/18 175 144 119 99 83 69 58 40 27 0.028
16/16 174 143 118 98 82 69 57 39 26 W1.4xW1.4
18/16 307 255 214 181 154 132 113 84 62 6x6 -
4 16/18 226 187 155 130 109 92 77 55 38 0.028
16/16 226 186 154 129 108 91 77 54 37 W1.4xW1.4
18/16 378 315 265 225 192 164 142 106 79 6x6 -
4 1/2 16/18 281 232 194 163 137 116 98 70 50 0.028
16/16 280 232 193 162 136 115 98 70 49 W1.4xW1.4
18/16 400 378 318 270 231 199 171 128 97
General Information
6x6 -
5 16/18 338 280 234 197 166 141 120 87 63 0.040
16/16 337 279 233 196 166 141 120 87 62 W2.0xW2.0
18/16 400 400 373 317 271 234 202 152 115 6x6 -
5 1/2 16/18 397 329 276 232 197 168 143 104 76 0.040
16/16 396 329 275 232 196 167 142 104 75 W2.0xW2.0
18/16 400 400 400 365 313 269 233 176 134 4x4 -
6 16/18 400 379 318 268 228 194 166 122 89 0.042
16/16 400 379 317 268 227 194 166 122 89 W1.4xW1.4

Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 71
1.5CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents

LIGHTWEIGHT CONCRETE
Composite Decks - Type 1.5CFDCA Cellular
PROPERTIES 6˝ 2 21 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 1 21 ˝
20/20 0.0358/0.0358 3.35 1 85 ˝
20/18 0.0358/0.0474
24.5
3.83 24 21 ˝ Coverage
18/20 0.0474/0.0358 3.95
Roof Deck

18/18 0.0474/0.0474 4.43


ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 50 1.912 0.370 0.370 0.352 0.323 0.288 0.380 8612 11372 2871 1146 2027
20/18 50 2.168 0.409 0.409 0.389 0.384 0.304 0.437 9101 13081 2871 1146 2027
18/20 50 2.273 0.471 0.471 0.461 0.393 0.415 0.445 12411 13324 3783 1913 3433
18/18 50 2.529 0.520 0.520 0.509 0.457 0.434 0.552 12985 16521 3783 1913 3433
CONSTRUCTION CLEAR SPANS
Composite Deck

Concrete Maximum Construction Concrete Notes:


Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) 3 2 accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft /ft )
accordance with SDI white paper ''Perforated Metal Deck Design with
20/20 10 - 1 11 - 10 11 - 11 3 - 11
Commentary''.
20/18 10 - 5 12 - 1 12 - 2 4 - 0
3 1/2 23 0.211 2. Web crippling design strengths* and maximum construction spans are
18/20 11 - 5 12 - 9 13 - 3 4 - 5
18/18 11 - 8 14 - 2 13 - 8 4 - 8 based on 1 1/2'' for end bearing and 3'' for interior bearing. Check web
20/20 9 - 7 11 - 2 11 - 4 3 - 9 crippling if minimums are not met.
20/18 9 - 10 11 - 7 11 - 8 3 - 10 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
4 28 0.252
18/20 10 - 10 12 - 9 12 - 10 4 - 3 Composite Steel Floor Deck and the following construction loading:
Lightweight Concrete (110 pcf)
Deep-Dek®
Long-Span Composite

18/18 11 - 2 13 - 11 13 - 1 4 - 7 ● Deck self-weight and concrete weight plus worst-case of either a 150
20/20 9 - 1 10 - 8 10 - 9 3 - 7 lb. concentrated load or a 20 psf uniform load; or
20/18 9 - 5 11 - 0 11 - 1 3 - 8 ● Deck self-weight plus a 50 psf uniform construcon load, whichever
4 1/2 32 0.294
18/20 10 - 5 12 - 6 12 - 5 4 - 2 controls.
18/18 10 - 8 13 - 6 12 - 8 4 - 6 4. Concrete weights do not include weight of deck.
20/20 8 - 9 10 - 3 10 - 4 3 - 5 5. Deck profile has been accounted for in determining concrete
Versa-Dek®

20/18 9 - 0 10 - 6 10 - 8 3 - 6 volumes. Deck and support deflections have not been included in
5 37 0.336
18/20 10 - 0 12 - 0 12 - 1 4 - 0 concrete volumes or weights.
18/18 10 - 3 13 - 1 12 - 4 4 - 4 6. Cantilever clear spans assume adjacent clear span is at least 3 times
20/20 8 - 5 9 - 10 9 - 11 3 - 3 longer than the cantilever clear span and no greater than spans
20/18 8 - 8 10 - 2 10 - 3 3 - 5
5 1/2 42 0.377 published above. Bearing width at perimeter support assumed to be 3''
18/20 9 - 8 11 - 7 11 - 9 3 - 11
minimum. Contact New Millennium otherwise.
18/18 9 - 11 12 - 7 12 - 0 4 - 2
20/20 8 - 1 9 - 6 9 - 7 3 - 2
20/18 8 - 5 9 - 9 9 - 10 3 - 3
6 46 0.419
Form Deck

18/20 9 - 4 11 - 3 11 - 5 3 - 9
18/18 9 - 7 12 - 1 11 - 9 4 - 0
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric (in2/ft)
Lightweight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)

20/20 244 204 172 146 125 108 94 71 54


20/18 243 203 171 146 125 108 93 70 53 6x6 -
Typical Fastener Layouts

3 1/2 0.028
18/20 229 191 161 137 117 101 87 65 49 W1.4xW1.4
18/18 229 191 161 136 117 100 86 65 49
20/20 312 262 221 189 162 140 122 93 71
20/18 312 261 221 188 162 140 121 92 71 6x6 -
4 0.028
18/20 295 247 209 178 152 131 114 86 66 W1.4xW1.4
18/18 295 247 208 177 152 131 113 86 65
20/20 385 323 273 234 201 174 151 116 89
20/18 385 322 273 233 200 173 151 115 89 6x6 -
4 1/2 0.028
18/20 366 306 259 221 190 164 142 109 83 W1.4xW1.4
18/18 365 306 259 221 189 164 142 108 83
20/20 400 386 328 280 241 209 182 140 109
20/18 400 386 327 280 241 209 182 140 108 6x6 -
5 0.040
18/20 400 368 312 267 229 198 173 132 102 W2.0xW2.0
General Information

18/18 400 368 312 266 229 198 172 132 102
20/20 400 400 383 328 283 246 214 165 129
20/18 400 400 383 328 283 245 214 165 128 6x6 -
5 1/2 0.040
18/20 400 400 367 313 270 234 204 156 121 W2.0xW2.0
18/18 400 400 366 313 270 234 203 156 121
20/20 400 400 400 377 326 283 247 191 149
20/18 400 400 400 377 325 282 246 190 148 4x4 -
6 0.042
18/20 400 400 400 361 312 270 236 181 141 W1.4xW1.4
18/18 400 400 400 361 311 270 235 181 141
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
72 www.newmill.com/digital-tools
1.5CFDCA Composite Floor Deck Cellular Acoustical

Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 1.5CFDCA Cellular
PROPERTIES 6˝ 2 21 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 1 21 ˝
18/16 0.0474/0.0598 4.94 1 85 ˝
16/18 0.0598/0.0474 24.5 5.07 24 21 ˝ Coverage
16/16 0.0598/0.0598 5.58

Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 2.801 0.567 0.567 0.555 0.527 0.451 0.579 13488 17350 3783 1913 3433
16/18 40 2.913 0.631 0.631 0.631 0.542 0.617 0.642 14775 15379 3798 2338 4234
16/16 40 3.185 0.688 0.688 0.687 0.621 0.637 0.706 15259 16920 3798 2338 4234

Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) 3 2 accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft /ft )
accordance with SDI white paper ''Perforated Metal Deck Design with
18/16 11 - 10 14 - 6 13 - 10 4 - 10
Commentary''.

Versa-Dek®
Long-Span Composite
3 1/2 16/18 23 12 - 2 13 - 7 14 - 1 4 - 8 0.211
2. Web crippling design strengths* and maximum construction spans are
16/16 12 - 4 14 - 2 14 - 6 4 - 10
based on 1 1/2'' for end bearing and 3'' for interior bearing. Check web
18/16 11 - 5 14 - 2 13 - 4 4 - 8
Lightweight Concrete (110 pcf)

crippling if minimums are not met.


4 16/18 28 11 - 8 13 - 7 13 - 8 4 - 6 0.252
3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
16/16 11 - 11 14 - 2 13 - 11 4 - 8
Composite Steel Floor Deck and the following construction loading:
18/16 10 - 11 13 - 9 12 - 11 4 - 7

Deep-Dek®
● Deck self-weight and concrete weight plus worst-case of either a 150
4 1/2 16/18 32 11 - 4 13 - 4 13 - 3 4 - 5 0.294
lb. concentrated load or a 20 psf uniform load; or
16/16 11 - 6 13 - 11 13 - 6 4 - 7
● Deck self-weight plus a 50 psf uniform construcon load, whichever
18/16 10 - 6 13 - 4 12 - 7 4 - 5
controls.
5 16/18 37 10 - 11 12 - 10 12 - 11 4 - 3 0.336
4. Concrete weights do not include weight of deck.
16/16 11 - 2 13 - 5 13 - 1 4 - 5
5. Deck profile has been accounted for in determining concrete
18/16 10 - 2 12 - 10 12 - 3 4 - 3
5 1/2 16/18 42 0.377 volumes. Deck and support deflections have not been included in
10 - 6 12 - 4 12 - 7 4 - 2
16/16 concrete volumes or weights.
10 - 10 12 - 11 12 - 9 4 - 3
18/16 6. Cantilever clear spans assume adjacent clear span is at least 3 times
9 - 10 12 - 4 11 - 11 4 - 1

Form Deck
6 16/18 46 0.419 longer than the cantilever clear span and no greater than spans
10 - 3 12 - 0 12 - 3 4 - 1
16/16 published above. Bearing width at perimeter support assumed to be 3''
10 - 6 12 - 6 12 - 6 4 - 2
minimum. Contact New Millennium otherwise.

SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire

Typical Fastener Layouts


Depth Gage Clear Span (ft - in) Welded Wire Area
LW Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)

(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric (in2/ft)


18/16 228 190 160 136 116 100 86 64 48 6x6 -
3 1/2 16/18 167 138 115 97 82 69 59 42 30 0.028
16/16 166 138 115 96 81 69 58 42 29 W1.4xW1.4
18/16 294 246 208 177 151 130 113 85 65 6x6 -
4 16/18 217 180 151 127 108 92 78 57 42 0.028
16/16 217 180 150 127 107 91 78 57 41 W1.4xW1.4
18/16 365 305 258 220 189 163 141 108 82 6x6 -
4 1/2 16/18 271 225 189 160 136 116 100 74 54 0.028
16/16 271 225 189 159 136 116 99 73 54 W1.4xW1.4
18/16 400 367 311 266 228 198 172 131 101
General Information
6x6 -
5 16/18 328 273 229 195 166 142 122 91 68 0.040
16/16 327 272 229 194 165 142 122 91 67 W2.0xW2.0
18/16 400 400 366 312 269 233 203 155 120 6x6 -
5 1/2 16/18 386 322 271 230 197 169 146 109 82 0.040
16/16 385 321 271 230 196 168 145 109 82 W2.0xW2.0
18/16 400 400 400 360 311 269 235 180 140 4x4 -
6 16/18 400 372 314 267 228 197 170 128 97 0.042
16/16 400 372 314 266 228 196 169 127 96 W1.4xW1.4

Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 73
1.5CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents

NORMAL-WEIGHT CONCRETE
Composite Decks - Type 1.5CFDCA Cellular
PROPERTIES 6˝ 2 21 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 1 21 ˝
20/20 0.0358/0.0358 3.35 1 85 ˝
20/18 0.0358/0.0474
24.5
3.83 24 21 ˝ Coverage
18/20 0.0474/0.0358 3.95
Roof Deck

18/18 0.0474/0.0474 4.43


ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 50 1.912 0.370 0.370 0.352 0.323 0.288 0.380 8612 11372 2871 1146 2027
20/18 50 2.168 0.409 0.409 0.389 0.384 0.304 0.437 9101 13081 2871 1146 2027
18/20 50 2.273 0.471 0.471 0.461 0.393 0.415 0.445 12411 13324 3783 1913 3433
18/18 50 2.529 0.520 0.520 0.509 0.457 0.434 0.552 12985 16521 3783 1913 3433
CONSTRUCTION CLEAR SPANS
Composite Deck

Concrete Maximum Construction Concrete Notes:


Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) 3 2 accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft /ft )
accordance with SDI white paper ''Perforated Metal Deck Design with
20/20 9 - 3 10 - 10 11 - 0 3 - 8
Commentary''.
20/18 9 - 7 11 - 2 11 - 4 3 - 9
3 1/2 31 0.211 2. Web crippling design strengths* and maximum construction spans are
18/20 10 - 7 12 - 9 12 - 7 4 - 3
18/18 10 - 10 13 - 8 12 - 10 4 - 6 based on 1 1/2'' for end bearing and 3'' for interior bearing. Check web
20/20 8 - 9 10 - 3 10 - 4 3 - 5 crippling if minimums are not met.
20/18 9 - 1 10 - 7 10 - 8 3 - 6 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
Normal-Weight Concrete (145 pcf)

4 37 0.252
18/20 10 - 0 12 - 1 12 - 1 4 - 0 Composite Steel Floor Deck and the following construction loading:
Deep-Dek®
Long-Span Composite

18/18 10 - 4 13 - 2 12 - 4 4 - 4 ● Deck self-weight and concrete weight plus worst-case of either a 150
20/20 8 - 4 9 - 9 9 - 10 3 - 3 lb. concentrated load or a 20 psf uniform load; or
20/18 8 - 7 10 - 0 10 - 2 3 - 4 ● Deck self-weight plus a 50 psf uniform construcon load, whichever
4 1/2 43 0.294
18/20 9 - 7 11 - 6 11 - 8 3 - 10 controls.
18/18 9 - 10 12 - 5 11 - 11 4 - 1 4. Concrete weights do not include weight of deck.
20/20 8 - 0 9 - 3 9 - 5 3 - 1 5. Deck profile has been accounted for in determining concrete
Versa-Dek®

20/18 8 - 3 9 - 7 9 - 8 3 - 2 volumes. Deck and support deflections have not been included in
5 49 0.336
18/20 9 - 2 11 - 0 11 - 4 3 - 9 concrete volumes or weights.
18/18 9 - 5 11 - 10 11 - 7 3 - 11 6. Cantilever clear spans assume adjacent clear span is at least 3 times
20/20 7 - 8 8 - 11 9 - 0 3 - 0 longer than the cantilever clear span and no greater than spans
20/18 7 - 11 9 - 2 9 - 3 3 - 1
5 1/2 55 0.377 published above. Bearing width at perimeter support assumed to be 3''
18/20 8 - 10 10 - 7 10 - 11 3 - 7
minimum. Contact New Millennium otherwise.
18/18 9 - 1 11 - 4 11 - 3 3 - 9
20/20 7 - 4 8 - 7 8 - 8 2 - 10
20/18 7 - 7 8 - 5 8 - 11 2 - 11
6 61 0.419
Form Deck

18/20 8 - 7 10 - 2 10 - 6 3 - 6
18/18 8 - 10 10 - 11 10 - 11 3 - 7
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in2/ft)
Normal-Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)

(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric
20/20 253 211 177 150 128 109 94 69 52
20/18 253 210 177 149 127 109 93 69 51 6x6 -
Typical Fastener Layouts

3 1/2 0.028
18/20 240 199 167 141 120 102 87 64 47 W1.4xW1.4
18/18 239 199 167 141 119 102 87 64 47
20/20 323 269 227 192 164 141 121 91 68
20/18 323 269 226 192 164 141 121 90 68 6x6 -
4 0.028
18/20 308 256 215 182 155 133 114 85 63 W1.4xW1.4
18/18 307 256 215 182 155 133 114 84 63
20/20 397 331 279 237 203 175 151 113 86
20/18 396 331 279 237 203 174 150 113 85 6x6 -
4 1/2 0.028
18/20 379 316 266 226 193 166 143 107 80 W1.4xW1.4
18/18 379 316 266 226 193 165 142 106 80
20/20 400 395 333 284 243 209 181 137 104
20/18 400 395 333 283 243 209 181 136 104 6x6 -
5 0.040
18/20 400 379 319 272 232 200 172 130 98 W2.0xW2.0
General Information

18/18 400 378 319 271 232 199 172 129 98


20/20 400 400 389 331 284 245 212 161 123
20/18 400 400 389 331 284 245 212 161 123 6x6 -
5 1/2 0.040
18/20 400 400 374 318 273 235 203 153 117 W2.0xW2.0
18/18 400 400 374 318 272 234 203 153 116
20/20 400 400 400 380 326 282 244 186 142
20/18 400 400 400 380 326 281 244 185 142 4x4 -
6 0.042
18/20 400 400 400 366 314 271 234 178 135 W1.4xW1.4
18/18 400 400 400 365 313 270 234 177 135
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
74 www.newmill.com/digital-tools
1.5CFDCA Composite Floor Deck Cellular Acoustical

Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 1.5CFDCA Cellular
PROPERTIES 6˝ 2 21 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 1 21 ˝
18/16 0.0474/0.0598 4.94 1 85 ˝
16/18 0.0598/0.0474 24.5 5.07 24 21 ˝ Coverage
16/16 0.0598/0.0598 5.58

Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 2.801 0.567 0.567 0.555 0.527 0.451 0.579 13488 17350 3783 1913 3433
16/18 40 2.913 0.631 0.631 0.631 0.542 0.617 0.642 14775 15379 3798 2338 4234
16/16 40 3.185 0.688 0.688 0.687 0.621 0.637 0.706 15259 16920 3798 2338 4234

Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) 3 2 accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft /ft )
accordance with SDI white paper ''Perforated Metal Deck Design with
18/16 11 - 2 13 - 11 13 - 1 4 - 7
Commentary''.

Versa-Dek®
Long-Span Composite
3 1/2 16/18 31 11 - 5 13 - 6 13 - 5 4 - 6 0.211
2. Web crippling design strengths* and maximum construction spans are
16/16 11 - 8 14 - 2 13 - 8 4 - 8
Normal-Weight Concrete (145 pcf)

based on 1 1/2'' for end bearing and 3'' for interior bearing. Check web
18/16 10 - 7 13 - 4 12 - 7 4 - 5
crippling if minimums are not met.
4 16/18 37 10 - 11 12 - 10 12 - 11 4 - 3 0.252
3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
16/16 11 - 3 13 - 5 13 - 2 4 - 5
Composite Steel Floor Deck and the following construction loading:
18/16 10 - 1 12 - 8 12 - 2 4 - 2

Deep-Dek®
● Deck self-weight and concrete weight plus worst-case of either a 150
4 1/2 16/18 43 10 - 5 12 - 3 12 - 6 4 - 2 0.294
lb. concentrated load or a 20 psf uniform load; or
16/16 10 - 9 12 - 10 12 - 9 4 - 3
● Deck self-weight plus a 50 psf uniform construcon load, whichever
18/16 9 - 8 12 - 1 11 - 10 4 - 0
controls.
5 16/18 49 10 - 1 11 - 9 12 - 1 4 - 0 0.336
4. Concrete weights do not include weight of deck.
16/16 10 - 4 12 - 3 12 - 4 4 - 1
5. Deck profile has been accounted for in determining concrete
18/16 9 - 4 11 - 7 11 - 6 3 - 10
5 1/2 16/18 55 0.377 volumes. Deck and support deflections have not been included in
9 - 8 11 - 3 11 - 8 3 - 10
16/16 concrete volumes or weights.
9 - 11 11 - 9 12 - 0 4 - 0
18/16 6. Cantilever clear spans assume adjacent clear span is at least 3 times
9 - 1 11 - 2 11 - 2 3 - 8

Form Deck
6 16/18 61 0.419 longer than the cantilever clear span and no greater than spans
9 - 5 10 - 10 11 - 3 3 - 9
16/16 published above. Bearing width at perimeter support assumed to be 3''
9 - 8 11 - 4 11 - 9 3 - 11
minimum. Contact New Millennium otherwise.

SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire

Typical Fastener Layouts


Depth Gage Clear Span (ft - in) Welded Wire Area
NW Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)

(in) 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 Fabric (in2/ft)


18/16 239 198 166 140 119 101 87 63 46 6x6 -
3 1/2 16/18 175 144 119 99 83 69 58 40 27 0.028
16/16 174 143 119 99 82 69 57 40 27 W1.4xW1.4
18/16 307 255 214 181 154 132 113 84 62 6x6 -
4 16/18 226 187 155 130 109 92 77 55 38 0.028
16/16 226 186 155 129 109 91 77 54 38 W1.4xW1.4
18/16 378 315 265 225 192 165 142 106 79 6x6 -
4 1/2 16/18 281 232 194 163 137 116 98 71 50 0.028
16/16 281 232 193 162 137 116 98 70 50 W1.4xW1.4
18/16 400 378 318 271 231 199 171 129 97
General Information
6x6 -
5 16/18 338 280 234 197 167 142 120 87 63 0.040
16/16 338 280 234 197 166 141 120 87 62 W2.0xW2.0
18/16 400 400 373 317 272 234 202 152 116 6x6 -
5 1/2 16/18 397 329 276 232 197 168 143 105 76 0.040
16/16 396 329 275 232 197 167 143 104 76 W2.0xW2.0
18/16 400 400 400 365 313 270 233 177 134 4x4 -
6 16/18 400 380 318 269 228 195 166 122 90 0.042
16/16 400 379 318 268 228 194 166 122 89 W1.4xW1.4

Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 75
2.0CFDC Composite Floor Deck Cellular
Table of Contents

LIGHTWEIGHT CONCRETE
Composite Decks - Type 2.0CFDC Cellular
PROPERTIES 5 81 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)

20/20 0.0358/0.0358 3.38 12˝ 5 81 ˝
20/18 0.0358/0.0474 3.92
24
18/20 0.0474/0.0358 3.95 24˝ Coverage
Roof Deck

18/18 0.0474/0.0474 4.47


ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 50 1.984 0.653 0.653 0.649 0.500 0.372 0.406 11126 12165 2362 584 1116
20/18 50 2.305 0.706 0.706 0.701 0.593 0.384 0.438 11497 13109 2362 584 1116
18/20 50 2.320 0.817 0.817 0.816 0.612 0.542 0.526 16228 15754 3118 975 1867
18/18 50 2.625 0.880 0.880 0.879 0.717 0.557 0.560 16670 16765 3118 975 1867
CONSTRUCTION CLEAR SPANS
Composite Deck

Concrete Maximum Construction Concrete Notes:


Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) 3 2 accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft /ft )
2. Web crippling design strengths* and maximum construction spans are
20/20 11 - 4 12 - 3 12 - 8 4 - 2
based on 2'' for end bearing and 4'' for interior bearing. Check web
20/18 11 - 6 12 - 8 13 - 1 4 - 4
4 28 0.250 crippling if minimums are not met.
18/20 12 - 7 14 - 1 14 - 5 4 - 9
18/18 12 - 9 14 - 3 14 - 9 4 - 11 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
20/20 10 - 10 12 - 0 12 - 5 4 - 1 Composite Steel Floor Deck and the following construction loading:
20/18 11 - 0 12 - 5 12 - 10 4 - 3 ● Deck self-weight and concrete weight plus worst-case of either a 150
4 1/2 32 0.292
18/20 12 - 2 13 - 10 14 - 1 4 - 8 lb. concentrated load or a 20 psf uniform load; or
Lightweight Concrete (110 pcf)
Deep-Dek®
Long-Span Composite

18/18 12 - 4 14 - 0 14 - 6 4 - 10 ● Deck self-weight plus a 50 psf uniform construcon load, whichever


20/20 10 - 4 11 - 6 11 - 11 3 - 11 controls.
20/18 10 - 6 11 - 11 12 - 4 4 - 1 4. Concrete weights do not include weight of deck.
5 37 0.333
18/20 11 - 10 13 - 3 13 - 6 4 - 6 5. Deck profile has been accounted for in determining concrete
18/18 12 - 0 13 - 5 13 - 11 4 - 7 volumes. Deck and support deflections have not been included in
20/20 9 - 11 11 - 1 11 - 6 3 - 10 concrete volumes or weights.
Versa-Dek®

20/18 10 - 1 11 - 6 11 - 10 3 - 11 6. Cantilever clear spans assume adjacent clear span is at least 3 times
5 1/2 41 0.375
18/20 11 - 6 12 - 9 13 - 1 4 - 4 longer than the cantilever clear span and no greater than spans
18/18 11 - 8 12 - 11 13 - 5 4 - 5 published above. Bearing width at perimeter support assumed to be 4''
20/20 9 - 7 10 - 9 11 - 1 3 - 8 minimum. Contact New Millennium otherwise.
20/18 9 - 9 11 - 1 11 - 5 3 - 9
6 46 0.417
18/20 11 - 3 12 - 4 12 - 7 4 - 2
18/18 11 - 5 12 - 6 13 - 0 4 - 4
20/20 9 - 3 10 - 5 10 - 9 3 - 7
20/18 9 - 5 10 - 9 11 - 0 3 - 8
6 1/2 50 0.458
Form Deck

18/20 10 - 11 11 - 11 12 - 3 4 - 1
18/18 11 - 2 12 - 2 12 - 6 4 - 2
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 7 - 0 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 Fabric (in2/ft)
Lightweight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)

20/20 254 188 163 142 109 85 66 52 40


20/18 254 187 162 141 108 84 66 51 40 6x6 -
Typical Fastener Layouts

4 0.028
18/20 332 247 215 189 147 116 92 74 59 W1.4xW1.4
18/18 332 246 215 188 146 115 92 73 59
20/20 309 229 198 173 134 104 82 65 51
20/18 309 228 198 173 133 104 81 64 50 6x6 -
4 1/2 0.028
18/20 400 301 262 230 180 142 114 92 74 W1.4xW1.4
18/18 400 300 262 230 179 142 113 91 73
20/20 368 272 236 207 160 125 99 78 62
20/18 367 271 236 206 159 124 98 78 61 6x6 -
5 0.028
18/20 400 358 313 275 215 170 137 110 90 W1.4xW1.4
18/18 400 358 312 274 214 170 136 110 89
20/20 400 317 276 241 187 147 116 92 74
20/18 400 317 275 241 186 146 116 92 73 6x6 -
5 1/2 0.040
18/20 400 400 365 321 251 200 161 130 106 W2.0xW2.0
General Information

18/18 400 400 365 321 251 199 160 130 106
20/20 400 364 317 277 215 169 134 107 86
20/18 400 363 316 276 215 169 134 107 85 6x6 -
6 0.040
18/20 400 400 400 369 289 230 186 151 123 W2.0xW2.0
18/18 400 400 400 368 289 230 185 150 123
20/20 400 400 358 314 244 192 153 122 98
20/18 400 400 358 313 243 192 152 122 98 4x4 -
6 1/2 0.042
18/20 400 400 400 400 328 262 211 172 141 W1.4xW1.4
18/18 400 400 400 400 328 261 211 171 140
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
76 www.newmill.com/digital-tools
2.0CFDC Composite Floor Deck Cellular

Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 2.0CFDC Cellular
PROPERTIES 5 81 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)

18/16 0.0474/0.0598 5.05 12˝ 5 81 ˝
16/18 0.0598/0.0474 24 5.08
16/16 0.0598/0.0598 5.66 24˝ Coverage

Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 2.969 0.940 0.940 0.939 0.819 0.571 0.585 17090 17522 3118 975 1867
16/18 40 2.984 1.050 1.050 1.048 0.877 0.737 0.694 17660 16611 3136 1191 2281
16/16 40 3.328 1.121 1.121 1.120 0.990 0.754 0.722 18070 17302 3136 1191 2281

Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft3/ft2)
2. Web crippling design strengths* and maximum construction spans are
18/16 12 - 11 14 - 6 15 - 0 5 - 0
based on 2'' for end bearing and 4'' for interior bearing. Check web

Versa-Dek®
Long-Span Composite
4 16/18 28 13 - 4 14 - 4 14 - 7 4 - 10 0.250
crippling if minimums are not met.
16/16 13 - 6 14 - 4 14 - 10 4 - 11
3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
18/16 12 - 6 14 - 3 14 - 8 4 - 10
Lightweight Concrete (110 pcf)

Composite Steel Floor Deck and the following construction loading:


4 1/2 16/18 32 12 - 10 14 - 1 14 - 4 4 - 9 0.292
● Deck self-weight and concrete weight plus worst-case of either a 150
16/16 13 - 0 14 - 1 14 - 7 4 - 10
lb. concentrated load or a 20 psf uniform load; or
18/16 12 - 2 13 - 8 14 - 2 4 - 8

Deep-Dek®
● Deck self-weight plus a 50 psf uniform construcon load, whichever
5 16/18 37 12 - 6 13 - 6 13 - 9 4 - 7 0.333
controls.
16/16 12 - 8 13 - 6 14 - 0 4 - 8
4. Concrete weights do not include weight of deck.
18/16 11 - 10 13 - 2 13 - 8 4 - 6
5. Deck profile has been accounted for in determining concrete
5 1/2 16/18 41 12 - 2 13 - 0 13 - 3 4 - 5 0.375
volumes. Deck and support deflections have not been included in
16/16 12 - 4 13 - 1 13 - 6 4 - 6
concrete volumes or weights.
18/16 11 - 7 12 - 9 13 - 2 4 - 4
6 16/18 46 0.417 6. Cantilever clear spans assume adjacent clear span is at least 3 times
11 - 11 12 - 7 12 - 10 4 - 3
16/16 longer than the cantilever clear span and no greater than spans
12 - 1 12 - 7 13 - 0 4 - 4
18/16 published above. Bearing width at perimeter support assumed to be 4''
11 - 4 12 - 4 12 - 9 4 - 3

Form Deck
6 1/2 16/18 50 0.458 minimum. Contact New Millennium otherwise.
11 - 8 12 - 2 12 - 5 4 - 1
16/16 11 - 10 12 - 3 12 - 8 4 - 2

SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire

Typical Fastener Layouts


Depth Gage Clear Span (ft - in) Welded Wire Area
LW Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)

(in) 7 - 0 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 Fabric (in2/ft)


18/16 331 246 214 187 146 115 91 73 58 6x6 -
4 16/18 322 239 208 182 141 111 88 70 56 0.028
16/16 321 238 207 181 140 110 87 70 55 W1.4xW1.4
18/16 400 300 261 229 179 141 113 90 73 6x6 -
4 1/2 16/18 392 292 254 223 173 137 109 87 70 0.028
16/16 392 291 253 222 173 136 108 87 70 W1.4xW1.4
18/16 400 357 312 274 214 169 136 109 89 6x6 -
5 16/18 400 348 304 266 208 164 132 106 86 0.028
16/16 400 348 303 266 207 164 131 105 85 W1.4xW1.4
18/16 400 400 364 320 250 199 160 129 105
General Information
6x6 -
5 1/2 16/18 400 400 356 312 244 194 155 125 102 0.040
16/16 400 400 355 312 243 193 155 125 101 W2.0xW2.0
18/16 400 400 400 368 288 229 185 150 122 6x6 -
6 16/18 400 400 400 360 282 224 180 146 119 0.040
16/16 400 400 400 359 281 223 179 145 118 W2.0xW2.0
18/16 400 400 400 400 327 261 210 171 140 4x4 -
6 1/2 16/18 400 400 400 400 320 255 205 167 136 0.042
16/16 400 400 400 400 320 254 205 166 136 W1.4xW1.4

Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 77
2.0CFDC Composite Floor Deck Cellular
Table of Contents

NORMAL-WEIGHT CONCRETE
Composite Decks - Type 2.0CFDC Cellular
PROPERTIES 5 81 ˝
Gage Thickness Cover Weight
(Hat/Pan)

(in) (in) (psf)
20/20 0.0358/0.0358 3.38 12˝ 5 81 ˝
20/18 0.0358/0.0474 3.92
24
18/20 0.0474/0.0358 3.95 24˝ Coverage
Roof Deck

18/18 0.0474/0.0474 4.47


ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 50 1.984 0.653 0.653 0.649 0.500 0.372 0.406 11126 12165 2362 584 1116
20/18 50 2.305 0.706 0.706 0.701 0.593 0.384 0.438 11497 13109 2362 584 1116
18/20 50 2.320 0.817 0.817 0.816 0.612 0.542 0.526 16228 15754 3118 975 1867
18/18 50 2.625 0.880 0.880 0.879 0.717 0.557 0.560 16670 16765 3118 975 1867
CONSTRUCTION CLEAR SPANS
Composite Deck

Concrete Maximum Construction Concrete Notes:


Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) 3 2 accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft /ft )
2. Web crippling design strengths* and maximum construction spans are
20/20 10 - 4 11 - 7 12 - 0 4 - 0
based on 2'' for end bearing and 4'' for interior bearing. Check web
20/18 10 - 6 11 - 11 12 - 4 4 - 1
4 36 0.250 crippling if minimums are not met.
18/20 11 - 10 13 - 4 13 - 7 4 - 6
18/18 12 - 0 13 - 6 14 - 0 4 - 8 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
20/20 9 - 10 11 - 0 11 - 5 3 - 9 Composite Steel Floor Deck and the following construction loading:
20/18 10 - 0 11 - 5 11 - 9 3 - 11 ● Deck self-weight and concrete weight plus worst-case of either a 150
Normal-Weight Concrete (145 pcf)

4 1/2 42 0.292
18/20 11 - 5 12 - 8 12 - 11 4 - 3 lb. concentrated load or a 20 psf uniform load; or
Deep-Dek®
Long-Span Composite

18/18 11 - 7 12 - 10 13 - 4 4 - 5 ● Deck self-weight plus a 50 psf uniform construcon load, whichever


20/20 9 - 5 10 - 6 10 - 11 3 - 7 controls.
20/18 9 - 6 10 - 10 11 - 2 3 - 8 4. Concrete weights do not include weight of deck.
5 48 0.333
18/20 11 - 1 12 - 1 12 - 5 4 - 1 5. Deck profile has been accounted for in determining concrete
18/18 11 - 3 12 - 4 12 - 9 4 - 3 volumes. Deck and support deflections have not been included in
20/20 9 - 0 10 - 1 10 - 5 3 - 5 concrete volumes or weights.
Versa-Dek®

20/18 9 - 2 10 - 3 10 - 9 3 - 7 6. Cantilever clear spans assume adjacent clear span is at least 3 times
5 1/2 54 0.375
18/20 10 - 8 11 - 7 11 - 11 3 - 11 longer than the cantilever clear span and no greater than spans
18/18 10 - 11 11 - 10 12 - 3 4 - 1 published above. Bearing width at perimeter support assumed to be 4''
20/20 8 - 8 9 - 9 10 - 1 3 - 4 minimum. Contact New Millennium otherwise.
20/18 8 - 9 9 - 3 10 - 1 3 - 4
6 60 0.417
18/20 10 - 4 11 - 2 11 - 5 3 - 9
18/18 10 - 6 11 - 4 11 - 9 3 - 11
20/20 8 - 4 9 - 5 9 - 9 3 - 3
20/18 8 - 6 8 - 11 9 - 4 3 - 1
6 1/2 66 0.458
Form Deck

18/20 10 - 0 10 - 9 11 - 1 3 - 8
18/18 10 - 3 11 - 0 11 - 4 3 - 9
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in2/ft)
Normal-Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)

(in) 7 - 0 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 Fabric
20/20 260 190 163 142 107 82 62 47 35
20/18 259 189 163 141 107 81 62 47 35 6x6 -
Typical Fastener Layouts

4 0.028
18/20 343 254 220 192 148 115 90 71 56 W1.4xW1.4
18/18 343 253 219 191 147 115 90 71 55
20/20 315 231 199 173 131 101 77 59 45
20/18 315 230 199 172 131 100 77 58 44 6x6 -
4 1/2 0.028
18/20 400 309 268 234 181 141 111 88 70 W1.4xW1.4
18/18 400 308 268 234 180 141 111 88 69
20/20 374 274 237 206 157 121 93 72 55
20/18 373 274 236 205 156 120 93 71 54 6x6 -
5 0.028
18/20 400 367 319 279 216 169 134 106 85 W1.4xW1.4
18/18 400 366 318 278 215 169 133 106 84
20/20 400 319 276 240 183 142 110 85 65
20/18 400 319 276 239 183 141 109 84 65 6x6 -
5 1/2 0.040
18/20 400 400 372 325 252 198 157 125 100 W2.0xW2.0
General Information

18/18 400 400 371 325 252 198 157 125 100
20/20 400 365 316 275 211 163 127 99 76
20/18 400 365 316 275 210 163 126 98 76 6x6 -
6 0.040
18/20 400 400 400 373 290 228 182 145 116 W2.0xW2.0
18/18 400 400 400 372 289 228 181 145 116
20/20 400 400 357 311 239 185 144 113 88
20/18 400 400 357 311 238 185 144 112 87 4x4 -
6 1/2 0.042
18/20 400 400 400 400 328 259 206 165 133 W1.4xW1.4
18/18 400 400 400 400 328 258 206 165 132
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
78 www.newmill.com/digital-tools
2.0CFDC Composite Floor Deck Cellular

Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 2.0CFDC Cellular
PROPERTIES 5 81 ˝
Gage Thickness Cover Weight
(Hat/Pan)

(in) (in) (psf)
18/16 0.0474/0.0598 5.05 12˝ 5 81 ˝
16/18 0.0598/0.0474 24 5.08
16/16 0.0598/0.0598 5.66 24˝ Coverage

Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 2.969 0.940 0.940 0.939 0.819 0.571 0.585 17090 17522 3118 975 1867
16/18 40 2.984 1.050 1.050 1.048 0.877 0.737 0.694 17660 16611 3136 1191 2281
16/16 40 3.328 1.121 1.121 1.120 0.990 0.754 0.722 18070 17302 3136 1191 2281

Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft3/ft2)
2. Web crippling design strengths* and maximum construction spans are
18/16 12 - 2 13 - 9 14 - 2 4 - 8
based on 2'' for end bearing and 4'' for interior bearing. Check web

Versa-Dek®
Long-Span Composite
4 16/18 36 12 - 6 13 - 7 13 - 10 4 - 7 0.250
crippling if minimums are not met.
16/16 12 - 8 13 - 7 14 - 1 4 - 8
Normal-Weight Concrete (145 pcf)

3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for


18/16 11 - 9 13 - 1 13 - 6 4 - 6
Composite Steel Floor Deck and the following construction loading:
4 1/2 16/18 42 12 - 1 12 - 11 13 - 2 4 - 4 0.292
● Deck self-weight and concrete weight plus worst-case of either a 150
16/16 12 - 3 12 - 11 13 - 5 4 - 5
lb. concentrated load or a 20 psf uniform load; or
18/16 11 - 5 12 - 6 12 - 11 4 - 3

Deep-Dek®
● Deck self-weight plus a 50 psf uniform construcon load, whichever
5 16/18 48 11 - 9 12 - 4 12 - 7 4 - 2 0.333
controls.
16/16 11 - 11 12 - 5 12 - 10 4 - 3
4. Concrete weights do not include weight of deck.
18/16 11 - 1 12 - 0 12 - 5 4 - 1
5. Deck profile has been accounted for in determining concrete
5 1/2 16/18 54 11 - 5 11 - 10 12 - 1 4 - 0 0.375
volumes. Deck and support deflections have not been included in
16/16 11 - 7 11 - 11 12 - 4 4 - 1
concrete volumes or weights.
18/16 10 - 9 11 - 7 12 - 0 4 - 0
6 16/18 60 0.417 6. Cantilever clear spans assume adjacent clear span is at least 3 times
11 - 2 11 - 5 11 - 9 3 - 11
16/16 longer than the cantilever clear span and no greater than spans
11 - 4 11 - 6 11 - 11 3 - 11
18/16 published above. Bearing width at perimeter support assumed to be 4''
10 - 5 11 - 2 11 - 7 3 - 10

Form Deck
6 1/2 16/18 66 0.458 minimum. Contact New Millennium otherwise.
10 - 10 11 - 0 11 - 4 3 - 9
16/16 11 - 0 11 - 1 11 - 5 3 - 9

SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire

Typical Fastener Layouts


Depth Gage Clear Span (ft - in) Welded Wire Area
NW Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)

(in) 7 - 0 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 Fabric (in2/ft)


18/16 342 252 219 191 147 114 89 70 55 6x6 -
4 16/18 334 246 213 186 143 111 87 68 53 0.028
16/16 334 246 213 185 142 110 86 67 52 W1.4xW1.4
18/16 400 307 267 233 180 140 110 87 69 6x6 -
4 1/2 16/18 400 301 261 228 175 137 107 84 66 0.028
16/16 400 300 260 227 175 136 107 84 66 W1.4xW1.4
18/16 400 366 318 278 215 168 133 105 83 6x6 -
5 16/18 400 358 311 272 210 164 129 102 81 0.028
16/16 400 357 310 271 209 164 129 102 80 W1.4xW1.4
18/16 400 400 370 324 251 197 156 124 99
General Information
6x6 -
5 1/2 16/18 400 400 363 318 246 193 153 121 96 0.040
16/16 400 400 363 317 245 192 152 121 96 W2.0xW2.0
18/16 400 400 400 372 289 227 180 144 115 6x6 -
6 16/18 400 400 400 365 283 223 177 141 112 0.040
16/16 400 400 400 365 283 222 176 140 112 W2.0xW2.0
18/16 400 400 400 400 327 258 205 164 132 4x4 -
6 1/2 16/18 400 400 400 400 322 253 201 161 129 0.042
16/16 400 400 400 400 321 253 201 160 128 W1.4xW1.4

Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 79
2.0CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents

LIGHTWEIGHT CONCRETE
Composite Decks - Type 2.0CFDCA Cellular
PROPERTIES 5 81 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)

20/20 0.0358/0.0358 3.25 12˝ 5 81 ˝
20/18 0.0358/0.0474 3.72
24
18/20 0.0474/0.0358 3.82 24˝ Coverage
Roof Deck

18/18 0.0474/0.0474 4.29


ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 50 1.818 0.621 0.621 0.617 0.487 0.367 0.403 10995 12057 2362 584 1116
20/18 50 2.069 0.670 0.670 0.665 0.563 0.379 0.433 11353 12967 2362 584 1116
18/20 50 2.154 0.777 0.777 0.776 0.597 0.535 0.519 16030 15537 3118 975 1867
18/18 50 2.405 0.836 0.836 0.835 0.691 0.550 0.555 16462 16618 3118 975 1867
CONSTRUCTION CLEAR SPANS
Composite Deck

Concrete Maximum Construction Concrete Notes:


Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) 3 2 accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft /ft )
accordance with SDI white paper ''Perforated Metal Deck Design with
20/20 11 - 3 12 - 2 12 - 8 4 - 2
Commentary''.
20/18 11 - 5 12 - 7 13 - 0 4 - 4
4 28 0.250 2. Web crippling design strengths* and maximum construction spans are
18/20 12 - 5 14 - 1 14 - 4 4 - 9
18/18 12 - 8 14 - 3 14 - 9 4 - 11 based on 2'' for end bearing and 4'' for interior bearing. Check web
20/20 10 - 9 12 - 0 12 - 5 4 - 1 crippling if minimums are not met.
20/18 10 - 11 12 - 4 12 - 9 4 - 3 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
4 1/2 32 0.292
18/20 12 - 0 13 - 10 14 - 0 4 - 8 Composite Steel Floor Deck and the following construction loading:
Lightweight Concrete (110 pcf)
Deep-Dek®
Long-Span Composite

18/18 12 - 3 13 - 11 14 - 4 4 - 9 ● Deck self-weight and concrete weight plus worst-case of either a 150
20/20 10 - 3 11 - 6 11 - 11 3 - 11 lb. concentrated load or a 20 psf uniform load; or
20/18 10 - 5 11 - 10 12 - 3 4 - 1 ● Deck self-weight plus a 50 psf uniform construcon load, whichever
5 37 0.333
18/20 11 - 8 13 - 3 13 - 6 4 - 6 controls.
18/18 11 - 10 13 - 5 13 - 10 4 - 7 4. Concrete weights do not include weight of deck.
20/20 9 - 10 11 - 1 11 - 5 3 - 9 5. Deck profile has been accounted for in determining concrete
Versa-Dek®

20/18 10 - 0 11 - 5 11 - 9 3 - 11 volumes. Deck and support deflections have not been included in
5 1/2 41 0.375
18/20 11 - 4 12 - 9 13 - 0 4 - 4 concrete volumes or weights.
18/18 11 - 7 12 - 11 13 - 4 4 - 5 6. Cantilever clear spans assume adjacent clear span is at least 3 times
20/20 9 - 6 10 - 8 11 - 1 3 - 8 longer than the cantilever clear span and no greater than spans
20/18 9 - 8 11 - 1 11 - 4 3 - 9
6 46 0.417 published above. Bearing width at perimeter support assumed to be 4''
18/20 11 - 1 12 - 4 12 - 6 4 - 2
minimum. Contact New Millennium otherwise.
18/18 11 - 3 12 - 6 12 - 11 4 - 3
20/20 9 - 2 10 - 4 10 - 8 3 - 6
20/18 9 - 4 10 - 8 11 - 0 3 - 8
6 1/2 50 0.458
Form Deck

18/20 10 - 9 11 - 11 12 - 2 4 - 0
18/18 11 - 0 12 - 1 12 - 6 4 - 2
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 7 - 0 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 Fabric (in2/ft)
Lightweight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)

20/20 255 188 163 142 109 85 66 52 41


20/18 254 187 162 141 109 84 66 52 40 6x6 -
Typical Fastener Layouts

4 0.028
18/20 332 247 215 189 147 116 92 74 59 W1.4xW1.4
18/18 332 247 215 188 146 115 92 74 59
20/20 310 229 199 173 134 104 82 65 51
20/18 309 228 198 173 133 104 82 64 50 6x6 -
4 1/2 0.028
18/20 400 301 263 230 180 142 114 92 74 W1.4xW1.4
18/18 400 301 262 230 179 142 113 91 74
20/20 368 272 237 207 160 125 99 78 62
20/18 367 272 236 206 159 125 98 78 62 6x6 -
5 0.028
18/20 400 359 313 275 215 171 137 111 90 W1.4xW1.4
18/18 400 358 312 274 214 170 136 110 89
20/20 400 317 276 241 187 147 116 93 74
20/18 400 317 276 241 187 146 116 92 73 6x6 -
5 1/2 0.040
18/20 400 400 366 321 252 200 161 130 106 W2.0xW2.0
General Information

18/18 400 400 365 321 251 200 160 130 106
20/20 400 364 317 277 215 169 134 107 86
20/18 400 363 316 277 215 169 134 107 85 6x6 -
6 0.040
18/20 400 400 400 369 289 231 186 151 123 W2.0xW2.0
18/18 400 400 400 369 289 230 185 151 123
20/20 400 400 358 314 244 192 153 122 98
20/18 400 400 358 313 243 192 153 122 98 4x4 -
6 1/2 0.042
18/20 400 400 400 400 328 262 211 172 141 W1.4xW1.4
18/18 400 400 400 400 328 261 211 172 140
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
80 www.newmill.com/digital-tools
2.0CFDCA Composite Floor Deck Cellular Acoustical

Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 2.0CFDCA Cellular
PROPERTIES 5 81 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 2˝
18/16 0.0474/0.0598 4.80 12˝ 5 81 ˝
16/18 0.0598/0.0474 24 4.90
16/16 0.0598/0.0598 5.41 24˝ Coverage

Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 2.672 0.891 0.891 0.890 0.770 0.563 0.577 16867 17283 3118 975 1867
16/18 40 2.763 0.997 0.997 0.996 0.844 0.728 0.689 17429 16502 3136 1191 2281
16/16 40 3.031 1.062 1.062 1.060 0.931 0.744 0.712 17819 17057 3136 1191 2281

Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft3/ft2)
accordance with SDI white paper ''Perforated Metal Deck Design with
18/16 12 - 10 14 - 5 14 - 11 4 - 11
Commentary''.

Versa-Dek®
Long-Span Composite
4 16/18 28 13 - 2 14 - 4 14 - 7 4 - 10 0.250
2. Web crippling design strengths* and maximum construction spans are
16/16 13 - 4 14 - 4 14 - 9 4 - 11
based on 2'' for end bearing and 4'' for interior bearing. Check web
18/16 12 - 4 14 - 2 14 - 6 4 - 10
Lightweight Concrete (110 pcf)

crippling if minimums are not met.


4 1/2 16/18 32 12 - 9 14 - 1 14 - 4 4 - 9 0.292
3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
16/16 12 - 11 14 - 1 14 - 6 4 - 10
Composite Steel Floor Deck and the following construction loading:
18/16 12 - 0 13 - 7 14 - 1 4 - 8

Deep-Dek®
● Deck self-weight and concrete weight plus worst-case of either a 150
5 16/18 37 12 - 4 13 - 6 13 - 9 4 - 7 0.333
lb. concentrated load or a 20 psf uniform load; or
16/16 12 - 6 13 - 6 13 - 11 4 - 7
● Deck self-weight plus a 50 psf uniform construcon load, whichever
18/16 11 - 8 13 - 1 13 - 7 4 - 6
controls.
5 1/2 16/18 41 12 - 0 13 - 0 13 - 3 4 - 5 0.375
4. Concrete weights do not include weight of deck.
16/16 12 - 2 13 - 0 13 - 5 4 - 5
5. Deck profile has been accounted for in determining concrete
18/16 11 - 5 12 - 8 13 - 1 4 - 4
6 16/18 46 0.417 volumes. Deck and support deflections have not been included in
11 - 9 12 - 7 12 - 10 4 - 3
16/16 concrete volumes or weights.
11 - 11 12 - 7 13 - 0 4 - 4
18/16 6. Cantilever clear spans assume adjacent clear span is at least 3 times
11 - 2 12 - 3 12 - 8 4 - 2

Form Deck
6 1/2 16/18 50 0.458 longer than the cantilever clear span and no greater than spans
11 - 6 12 - 2 12 - 5 4 - 1
16/16 published above. Bearing width at perimeter support assumed to be 4''
11 - 8 12 - 2 12 - 7 4 - 2
minimum. Contact New Millennium otherwise.

SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire

Typical Fastener Layouts


Depth Gage Clear Span (ft - in) Welded Wire Area
LW Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)

(in) 7 - 0 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 Fabric (in2/ft)


18/16 331 246 214 188 146 115 91 73 59 6x6 -
4 16/18 322 239 208 182 141 111 88 70 56 0.028
16/16 321 238 207 181 141 111 88 70 56 W1.4xW1.4
18/16 400 300 262 229 179 141 113 91 73 6x6 -
4 1/2 16/18 392 292 254 223 173 137 109 88 70 0.028
16/16 392 291 254 222 173 136 109 87 70 W1.4xW1.4
18/16 400 358 312 274 214 170 136 110 89 6x6 -
5 16/18 400 348 304 266 208 165 132 106 86 0.028
16/16 400 348 303 266 207 164 131 106 85 W1.4xW1.4
18/16 400 400 365 320 251 199 160 129 105
General Information
6x6 -
5 1/2 16/18 400 400 356 312 244 194 155 126 102 0.040
16/16 400 400 355 312 244 193 155 125 101 W2.0xW2.0
18/16 400 400 400 368 288 230 185 150 122 6x6 -
6 16/18 400 400 400 360 282 224 180 146 119 0.040
16/16 400 400 400 359 281 224 180 146 118 W2.0xW2.0
18/16 400 400 400 400 327 261 210 171 140 4x4 -
6 1/2 16/18 400 400 400 400 320 255 206 167 136 0.042
16/16 400 400 400 400 320 255 205 166 136 W1.4xW1.4

Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 81
2.0CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents

NORMAL-WEIGHT CONCRETE
Composite Decks - Type 2.0CFDCA Cellular
PROPERTIES 5 81 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf)

20/20 0.0358/0.0358 3.25 12˝ 5 81 ˝
20/18 0.0358/0.0474 3.72
24
18/20 0.0474/0.0358 3.82 24˝ Coverage
Roof Deck

18/18 0.0474/0.0474 4.29


ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 50 1.818 0.621 0.621 0.617 0.487 0.367 0.403 10995 12057 2362 584 1116
20/18 50 2.069 0.670 0.670 0.665 0.563 0.379 0.433 11353 12967 2362 584 1116
18/20 50 2.154 0.777 0.777 0.776 0.597 0.535 0.519 16030 15537 3118 975 1867
18/18 50 2.405 0.836 0.836 0.835 0.691 0.550 0.555 16462 16618 3118 975 1867
CONSTRUCTION CLEAR SPANS
Composite Deck

Concrete Maximum Construction Concrete Notes:


Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) 3 2 accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft /ft )
accordance with SDI white paper ''Perforated Metal Deck Design with
20/20 10 - 4 11 - 6 11 - 11 3 - 11
Commentary''.
20/18 10 - 6 11 - 11 12 - 4 4 - 1
4 36 0.250 2. Web crippling design strengths* and maximum construction spans are
18/20 11 - 9 13 - 4 13 - 6 4 - 6
18/18 11 - 11 13 - 5 13 - 11 4 - 7 based on 2'' for end bearing and 4'' for interior bearing. Check web
20/20 9 - 9 11 - 0 11 - 4 3 - 9 crippling if minimums are not met.
20/18 9 - 11 11 - 4 11 - 8 3 - 10 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
Normal-Weight Concrete (145 pcf)

4 1/2 42 0.292
18/20 11 - 4 12 - 8 12 - 10 4 - 3 Composite Steel Floor Deck and the following construction loading:
Deep-Dek®
Long-Span Composite

18/18 11 - 6 12 - 10 13 - 3 4 - 5 ● Deck self-weight and concrete weight plus worst-case of either a 150
20/20 9 - 4 10 - 6 10 - 10 3 - 7 lb. concentrated load or a 20 psf uniform load; or
20/18 9 - 6 10 - 10 11 - 2 3 - 8 ● Deck self-weight plus a 50 psf uniform construcon load, whichever
5 48 0.333
18/20 10 - 11 12 - 1 12 - 4 4 - 1 controls.
18/18 11 - 1 12 - 3 12 - 8 4 - 2 4. Concrete weights do not include weight of deck.
20/20 8 - 11 10 - 1 10 - 5 3 - 5 5. Deck profile has been accounted for in determining concrete
Versa-Dek®

20/18 9 - 1 10 - 5 10 - 8 3 - 6 volumes. Deck and support deflections have not been included in
5 1/2 54 0.375
18/20 10 - 6 11 - 7 11 - 10 3 - 11 concrete volumes or weights.
18/18 10 - 9 11 - 9 12 - 2 4 - 0 6. Cantilever clear spans assume adjacent clear span is at least 3 times
20/20 8 - 7 9 - 8 10 - 0 3 - 4 longer than the cantilever clear span and no greater than spans
20/18 8 - 9 10 - 0 10 - 3 3 - 5
6 60 0.417 published above. Bearing width at perimeter support assumed to be 4''
18/20 10 - 2 11 - 2 11 - 4 3 - 9
minimum. Contact New Millennium otherwise.
18/18 10 - 4 11 - 4 11 - 9 3 - 11
20/20 8 - 3 9 - 4 9 - 8 3 - 2
20/18 8 - 5 9 - 4 9 - 11 3 - 3
6 1/2 66 0.458
Form Deck

18/20 9 - 10 10 - 9 11 - 0 3 - 8
18/18 10 - 1 10 - 11 11 - 4 3 - 9
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in2/ft)
Normal-Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)

(in) 7 - 0 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 Fabric
20/20 260 190 164 142 107 82 62 47 35
20/18 259 189 163 141 107 81 62 47 35 6x6 -
Typical Fastener Layouts

4 0.028
18/20 344 254 220 192 148 115 90 71 56 W1.4xW1.4
18/18 343 253 220 192 147 115 90 71 55
20/20 316 231 199 173 131 101 77 59 45
20/18 315 230 199 172 131 100 77 59 44 6x6 -
4 1/2 0.028
18/20 400 309 268 234 181 142 112 88 70 W1.4xW1.4
18/18 400 308 268 234 180 141 111 88 69
20/20 374 274 237 206 157 121 93 72 55
20/18 374 274 237 205 157 120 93 71 54 6x6 -
5 0.028
18/20 400 367 319 279 216 169 134 106 85 W1.4xW1.4
18/18 400 366 318 278 215 169 134 106 84
20/20 400 319 276 240 184 142 110 85 65
20/18 400 319 276 240 183 141 109 85 65 6x6 -
5 1/2 0.040
18/20 400 400 372 325 252 198 157 126 100 W2.0xW2.0
General Information

18/18 400 400 371 325 252 198 157 125 100
20/20 400 365 316 275 211 163 127 99 76
20/18 400 365 316 275 210 163 127 98 76 6x6 -
6 0.040
18/20 400 400 400 373 290 228 182 145 116 W2.0xW2.0
18/18 400 400 400 372 289 228 181 145 116
20/20 400 400 357 311 239 185 145 113 88
20/18 400 400 357 311 238 185 144 112 87 4x4 -
6 1/2 0.042
18/20 400 400 400 400 328 259 206 166 133 W1.4xW1.4
18/18 400 400 400 400 328 259 206 165 133
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
82 www.newmill.com/digital-tools
2.0CFDCA Composite Floor Deck Cellular Acoustical

Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 2.0CFDCA Cellular
PROPERTIES 5 81 ˝
Gage Thickness Cover Weight
(Hat/Pan) (in) (in) (psf) 2˝
18/16 0.0474/0.0598 4.80 12˝ 5 81 ˝
16/18 0.0598/0.0474 24 4.90
16/16 0.0598/0.0598 5.41 24˝ Coverage

Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 2.672 0.891 0.891 0.890 0.770 0.563 0.577 16867 17283 3118 975 1867
16/18 40 2.763 0.997 0.997 0.996 0.844 0.728 0.689 17429 16502 3136 1191 2281
16/16 40 3.031 1.062 1.062 1.060 0.931 0.744 0.712 17819 17057 3136 1191 2281

Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft3/ft2)
accordance with SDI white paper ''Perforated Metal Deck Design with
18/16 12 - 1 13 - 8 14 - 2 4 - 8
Commentary''.

Versa-Dek®
Long-Span Composite
4 16/18 36 12 - 5 13 - 7 13 - 10 4 - 7 0.250
2. Web crippling design strengths* and maximum construction spans are
16/16 12 - 6 13 - 7 14 - 0 4 - 8
Normal-Weight Concrete (145 pcf)

based on 2'' for end bearing and 4'' for interior bearing. Check web
18/16 11 - 8 13 - 0 13 - 6 4 - 6
crippling if minimums are not met.
4 1/2 16/18 42 12 - 0 12 - 11 13 - 2 4 - 4 0.292
3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
16/16 12 - 1 12 - 11 13 - 4 4 - 5
Composite Steel Floor Deck and the following construction loading:
18/16 11 - 3 12 - 5 12 - 11 4 - 3

Deep-Dek®
● Deck self-weight and concrete weight plus worst-case of either a 150
5 16/18 48 11 - 7 12 - 4 12 - 7 4 - 2 0.333
lb. concentrated load or a 20 psf uniform load; or
16/16 11 - 9 12 - 4 12 - 9 4 - 3
● Deck self-weight plus a 50 psf uniform construcon load, whichever
18/16 10 - 11 12 - 0 12 - 5 4 - 1
controls.
5 1/2 16/18 54 11 - 4 11 - 10 12 - 1 4 - 0 0.375
4. Concrete weights do not include weight of deck.
16/16 11 - 5 11 - 10 12 - 3 4 - 1
5. Deck profile has been accounted for in determining concrete
18/16 10 - 7 11 - 6 11 - 11 3 - 11
6 16/18 60 0.417 volumes. Deck and support deflections have not been included in
11 - 0 11 - 5 11 - 9 3 - 11
16/16 concrete volumes or weights.
11 - 2 11 - 5 11 - 10 3 - 11
18/16 6. Cantilever clear spans assume adjacent clear span is at least 3 times
10 - 3 11 - 2 11 - 6 3 - 10

Form Deck
6 1/2 16/18 66 0.458 longer than the cantilever clear span and no greater than spans
10 - 8 11 - 0 11 - 4 3 - 9
16/16 published above. Bearing width at perimeter support assumed to be 4''
10 - 10 11 - 0 11 - 5 3 - 9
minimum. Contact New Millennium otherwise.

SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire

Typical Fastener Layouts


Depth Gage Clear Span (ft - in) Welded Wire Area
NW Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)

(in) 7 - 0 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 Fabric (in2/ft)


18/16 343 253 219 191 147 114 90 70 55 6x6 -
4 16/18 335 247 214 186 143 111 87 68 53 0.028
16/16 334 246 213 186 142 110 86 67 52 W1.4xW1.4
18/16 400 308 267 233 180 141 111 87 69 6x6 -
4 1/2 16/18 400 301 261 228 175 137 107 85 66 0.028
16/16 400 300 260 227 175 136 107 84 66 W1.4xW1.4
18/16 400 366 318 278 215 168 133 106 84 6x6 -
5 16/18 400 358 311 272 210 164 130 103 81 0.028
16/16 400 358 311 271 210 164 129 102 81 W1.4xW1.4
18/16 400 400 371 324 251 198 157 125 99
General Information
6x6 -
5 1/2 16/18 400 400 364 318 246 193 153 121 97 0.040
16/16 400 400 363 317 246 193 152 121 96 W2.0xW2.0
18/16 400 400 400 372 289 227 181 144 115 6x6 -
6 16/18 400 400 400 365 283 223 177 141 113 0.040
16/16 400 400 400 365 283 222 176 141 112 W2.0xW2.0
18/16 400 400 400 400 327 258 205 165 132 4x4 -
6 1/2 16/18 400 400 400 400 322 253 202 161 129 0.042
16/16 400 400 400 400 321 253 201 161 129 W1.4xW1.4

Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 83
3.0CFDC Composite Floor Deck Cellular
Table of Contents

LIGHTWEIGHT CONCRETE
Composite Decks - Type 3.0CFDC Cellular
PROPERTIES 5˝
Gage Thickness Cover Weight 3˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 3.58 12˝ 5˝
20/18 0.0358/0.0474 4.12
24
18/20 0.0474/0.0358 4.21 24˝ Coverage
Roof Deck

18/18 0.0474/0.0474 4.73


ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 50 2.102 1.522 1.522 1.515 1.180 0.567 0.633 16964 18956 2564 625 1246
20/18 50 2.422 1.623 1.623 1.611 1.372 0.595 0.682 17820 20416 2564 625 1246
18/20 50 2.476 1.906 1.906 1.905 1.421 0.862 0.826 25798 24720 4491 1049 2079
18/18 50 2.781 2.040 2.040 2.039 1.670 0.879 0.880 26305 26354 4491 1049 2079
CONSTRUCTION CLEAR SPANS
Composite Deck

Concrete Maximum Construction Concrete Notes:


Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft3/ft2)
2. Web crippling design strengths* and maximum construction spans are
20/20 14 - 1 14 - 11 15 - 5 5 - 1
based on 2 1/2'' for end bearing and 5'' for interior bearing. Check web
20/18 14 - 5 15 - 5 15 - 11 5 - 3
5 32 0.292 crippling if minimums are not met.
18/20 15 - 0 17 - 3 17 - 8 5 - 10
18/18 15 - 3 17 - 7 17 - 10 5 - 11 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
20/20 13 - 5 14 - 4 14 - 10 4 - 11 Composite Steel Floor Deck and the following construction loading:
20/18 13 - 9 14 - 10 15 - 4 5 - 1 ● Deck self-weight and concrete weight plus worst-case of either a 150
5 1/2 37 0.333
18/20 14 - 7 16 - 8 17 - 0 5 - 8 lb. concentrated load or a 20 psf uniform load; or
Lightweight Concrete (110 pcf)
Deep-Dek®
Long-Span Composite

18/18 14 - 10 16 - 10 17 - 4 5 - 9 ● Deck self-weight plus a 50 psf uniform construcon load, whichever


20/20 12 - 10 13 - 10 14 - 3 4 - 9 controls.
20/18 13 - 2 14 - 3 14 - 9 4 - 11 4. Concrete weights do not include weight of deck.
6 41 0.375
18/20 14 - 2 16 - 0 16 - 4 5 - 5 5. Deck profile has been accounted for in determining concrete
18/18 14 - 5 16 - 3 16 - 10 5 - 7 volumes. Deck and support deflections have not been included in
20/20 12 - 4 13 - 4 13 - 10 4 - 7 concrete volumes or weights.
Versa-Dek®

20/18 12 - 8 13 - 9 14 - 3 4 - 9 6. Cantilever clear spans assume adjacent clear span is at least 3 times
6 1/2 46 0.417
18/20 13 - 10 15 - 6 15 - 10 5 - 3 longer than the cantilever clear span and no greater than spans
18/18 14 - 1 15 - 9 16 - 3 5 - 5 published above. Bearing width at perimeter support assumed to be 5''
20/20 11 - 11 12 - 11 13 - 4 4 - 5 minimum. Contact New Millennium otherwise.
20/18 12 - 3 13 - 4 13 - 9 4 - 7
7 50 0.458
18/20 13 - 7 15 - 0 15 - 4 5 - 1
18/18 13 - 9 15 - 3 15 - 9 5 - 3
20/20 11 - 6 12 - 6 12 - 11 4 - 3
20/18 11 - 10 12 - 7 13 - 4 4 - 5
7 1/2 55 0.500
Form Deck

18/20 13 - 4 14 - 6 14 - 10 4 - 11
18/18 13 - 6 14 - 9 15 - 3 5 - 1
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0 16 - 0 Fabric (in2/ft)
Lightweight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)

20/20 325 249 195 155 125 101 82 67 55


20/18 325 249 195 155 124 100 82 66 54 6x6 -
Typical Fastener Layouts

5 0.028
18/20 400 328 259 208 168 132 106 86 71 W1.4xW1.4
18/18 400 328 258 207 168 132 106 86 71
20/20 381 292 229 182 147 119 97 80 65
20/18 380 292 229 182 146 119 97 79 64 6x6 -
5 1/2 0.028
18/20 400 384 303 244 198 163 135 112 92 W1.4xW1.4
18/18 400 384 303 243 198 162 134 112 92
20/20 400 338 265 212 171 139 113 93 76
20/18 400 338 265 211 170 138 113 93 76 6x6 -
6 0.028
18/20 400 400 351 282 230 189 157 131 110 W1.4xW1.4
18/18 400 400 351 282 230 189 156 130 109
20/20 400 386 304 242 196 159 131 108 88
20/18 400 386 303 242 195 159 130 107 88 6x6 -
6 1/2 0.040
18/20 400 400 400 323 264 217 181 151 126 W2.0xW2.0
General Information

18/18 400 400 400 323 263 217 180 150 126
20/20 400 400 343 274 222 181 149 123 101
20/18 400 400 343 274 221 181 148 122 101 6x6 -
7 0.040
18/20 400 400 400 366 299 247 205 172 144 W2.0xW2.0
18/18 400 400 400 366 298 246 205 171 144
20/20 400 400 384 307 249 203 167 138 114
20/18 400 400 384 307 248 203 167 138 114 4x4 -
7 1/2 0.042
18/20 400 400 400 400 335 277 231 193 163 W1.4xW1.4
18/18 400 400 400 400 335 276 230 193 162
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
84 www.newmill.com/digital-tools
3.0CFDC Composite Floor Deck Cellular

Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 3.0CFDC Cellular
PROPERTIES 5˝
Gage Thickness Cover Weight 3˝
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 5.32 12˝ 5˝
16/18 0.0598/0.0474 24 5.41
16/16 0.0598/0.0598 6.00 24˝ Coverage

Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 3.125 2.167 2.167 2.166 1.887 0.883 0.914 26446 27359 4491 1049 2079
16/18 40 3.180 2.441 2.441 2.440 2.048 1.169 1.097 27991 26278 4848 1285 2537
16/16 40 3.524 2.594 2.594 2.593 2.289 1.189 1.136 28485 27206 4848 1285 2537

Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft3/ft2)
2. Web crippling design strengths* and maximum construction spans are
18/16 15 - 5 17 - 9 18 - 1 6 - 0
based on 2 1/2'' for end bearing and 5'' for interior bearing. Check web

Versa-Dek®
Long-Span Composite
5 16/18 32 15 - 10 17 - 7 18 - 0 6 - 0 0.292
crippling if minimums are not met.
16/16 16 - 1 17 - 8 18 - 3 6 - 1
3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
18/16 15 - 0 17 - 1 17 - 7 5 - 10
Lightweight Concrete (110 pcf)

Composite Steel Floor Deck and the following construction loading:


5 1/2 16/18 37 15 - 5 16 - 11 17 - 4 5 - 9 0.333
● Deck self-weight and concrete weight plus worst-case of either a 150
16/16 15 - 7 17 - 0 17 - 7 5 - 10
lb. concentrated load or a 20 psf uniform load; or
18/16 14 - 7 16 - 6 17 - 1 5 - 8

Deep-Dek®
● Deck self-weight plus a 50 psf uniform construcon load, whichever
6 16/18 41 15 - 0 16 - 4 16 - 9 5 - 7 0.375
controls.
16/16 15 - 2 16 - 4 16 - 11 5 - 7
4. Concrete weights do not include weight of deck.
18/16 14 - 3 15 - 11 16 - 6 5 - 6
5. Deck profile has been accounted for in determining concrete
6 1/2 16/18 46 14 - 8 15 - 9 16 - 2 5 - 4 0.417
volumes. Deck and support deflections have not been included in
16/16 14 - 10 15 - 10 16 - 5 5 - 5
concrete volumes or weights.
18/16 13 - 11 15 - 5 16 - 0 5 - 4
7 16/18 50 0.458 6. Cantilever clear spans assume adjacent clear span is at least 3 times
14 - 4 15 - 3 15 - 8 5 - 2
16/16 longer than the cantilever clear span and no greater than spans
14 - 6 15 - 4 15 - 11 5 - 3
18/16 published above. Bearing width at perimeter support assumed to be 5''
13 - 8 15 - 0 15 - 6 5 - 2

Form Deck
7 1/2 16/18 55 0.500 minimum. Contact New Millennium otherwise.
14 - 1 14 - 10 15 - 3 5 - 1
16/16 14 - 3 14 - 11 15 - 5 5 - 1

SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire

Typical Fastener Layouts


Depth Gage Clear Span (ft - in) Welded Wire Area
LW Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)

(in) 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0 16 - 0 Fabric (in2/ft)


18/16 400 327 258 207 168 132 106 86 71 6x6 -
5 16/18 384 296 232 186 150 122 100 82 68 0.028
16/16 384 295 232 185 149 122 100 82 67 W1.4xW1.4
18/16 400 383 302 243 197 162 134 111 92 6x6 -
5 1/2 16/18 400 346 273 218 176 144 119 98 81 0.028
16/16 400 346 272 217 176 144 118 97 80 W1.4xW1.4
18/16 400 400 350 281 229 188 156 130 108 6x6 -
6 16/18 400 400 316 253 205 168 138 115 95 0.028
16/16 400 400 316 253 205 167 138 114 95 W1.4xW1.4
18/16 400 400 400 322 263 216 179 150 125
General Information
6x6 -
6 1/2 16/18 400 400 362 291 236 194 160 133 110 0.040
16/16 400 400 362 290 235 193 159 132 110 W2.0xW2.0
18/16 400 400 400 365 298 246 204 171 143 6x6 -
7 16/18 400 400 400 330 268 220 182 152 126 0.040
16/16 400 400 400 329 268 220 182 151 126 W2.0xW2.0
18/16 400 400 400 400 334 276 230 192 162 4x4 -
7 1/2 16/18 400 400 400 370 302 248 205 171 143 0.042
16/16 400 400 400 370 301 247 205 171 143 W1.4xW1.4

Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 85
3.0CFDC Composite Floor Deck Cellular
Table of Contents

NORMAL-WEIGHT CONCRETE
Composite Decks - Type 3.0CFDC Cellular
PROPERTIES 5˝
Gage Thickness Cover Weight 3˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 3.58 12˝ 5˝
20/18 0.0358/0.0474 4.12
24
18/20 0.0474/0.0358 4.21 24˝ Coverage
Roof Deck

18/18 0.0474/0.0474 4.73


ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 50 2.102 1.522 1.522 1.515 1.180 0.567 0.633 16964 18956 2564 625 1246
20/18 50 2.422 1.623 1.623 1.611 1.372 0.595 0.682 17820 20416 2564 625 1246
18/20 50 2.476 1.906 1.906 1.905 1.421 0.862 0.826 25798 24720 4491 1049 2079
18/18 50 2.781 2.040 2.040 2.039 1.670 0.879 0.880 26305 26354 4491 1049 2079
CONSTRUCTION CLEAR SPANS
Composite Deck

Concrete Maximum Construction Concrete Notes:


Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft3/ft2)
2. Web crippling design strengths* and maximum construction spans are
20/20 12 - 9 13 - 8 14 - 2 4 - 8
based on 2 1/2'' for end bearing and 5'' for interior bearing. Check web
20/18 13 - 1 14 - 2 14 - 8 4 - 10
5 42 0.292 crippling if minimums are not met.
18/20 14 - 2 15 - 11 16 - 3 5 - 5
18/18 14 - 4 16 - 2 16 - 8 5 - 6 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
20/20 12 - 1 13 - 1 13 - 7 4 - 6 Composite Steel Floor Deck and the following construction loading:
20/18 12 - 5 13 - 6 14 - 0 4 - 8 ● Deck self-weight and concrete weight plus worst-case of either a 150
Normal-Weight Concrete (145 pcf)

5 1/2 48 0.333
18/20 13 - 8 15 - 2 15 - 6 5 - 2 lb. concentrated load or a 20 psf uniform load; or
Deep-Dek®
Long-Span Composite

18/18 13 - 11 15 - 5 16 - 0 5 - 4 ● Deck self-weight plus a 50 psf uniform construcon load, whichever


20/20 11 - 7 12 - 7 13 - 0 4 - 4 controls.
20/18 11 - 10 12 - 8 13 - 5 4 - 5 4. Concrete weights do not include weight of deck.
6 54 0.375
18/20 13 - 4 14 - 7 14 - 11 4 - 11 5. Deck profile has been accounted for in determining concrete
18/18 13 - 6 14 - 10 15 - 4 5 - 1 volumes. Deck and support deflections have not been included in
20/20 11 - 1 11 - 10 12 - 6 4 - 2 concrete volumes or weights.
Versa-Dek®

20/18 11 - 5 11 - 9 12 - 11 4 - 3 6. Cantilever clear spans assume adjacent clear span is at least 3 times
6 1/2 60 0.417
18/20 13 - 0 14 - 0 14 - 4 4 - 9 longer than the cantilever clear span and no greater than spans
18/18 13 - 2 14 - 3 14 - 9 4 - 11 published above. Bearing width at perimeter support assumed to be 5''
20/20 10 - 8 11 - 2 12 - 1 4 - 0 minimum. Contact New Millennium otherwise.
20/18 11 - 0 11 - 2 12 - 5 4 - 1
7 66 0.458
18/20 12 - 9 13 - 6 13 - 10 4 - 7
18/18 12 - 11 13 - 10 14 - 3 4 - 9
20/20 10 - 4 10 - 6 11 - 8 3 - 10
20/18 10 - 7 10 - 6 11 - 8 3 - 10
7 1/2 73 0.500
Form Deck

18/20 12 - 6 13 - 1 13 - 5 4 - 5
18/18 12 - 8 13 - 4 13 - 10 4 - 7
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in2/ft)
Normal-Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)

(in) 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0 16 - 0 Fabric
20/20 332 252 196 154 122 97 77 61 48
20/18 331 252 195 153 121 96 77 61 48 6x6 -
Typical Fastener Layouts

5 0.028
18/20 400 336 264 210 169 137 112 91 75 W1.4xW1.4
18/18 400 336 263 209 168 136 111 91 74
20/20 388 296 230 181 144 115 92 73 58
20/18 388 295 229 180 143 114 91 73 58 6x6 -
5 1/2 0.028
18/20 400 394 309 246 199 162 132 108 89 W1.4xW1.4
18/18 400 394 309 246 198 161 132 108 88
20/20 400 342 266 210 167 134 107 86 69
20/18 400 342 266 209 167 133 107 86 68 6x6 -
6 0.028
18/20 400 400 358 286 231 188 154 127 104 W1.4xW1.4
18/18 400 400 357 285 230 187 153 126 104
20/20 400 390 304 240 192 154 124 100 80
20/18 400 390 304 240 191 153 123 99 79 6x6 -
6 1/2 0.040
18/20 400 400 400 327 264 216 177 146 120 W2.0xW2.0
General Information

18/18 400 400 400 326 264 215 177 145 120
20/20 400 400 343 272 217 175 141 114 91
20/18 400 400 343 271 217 174 140 113 91 6x6 -
7 0.040
18/20 400 400 400 370 299 245 201 166 137 W2.0xW2.0
18/18 400 400 400 369 299 244 201 166 137
20/20 400 400 384 304 243 196 159 128 104
20/18 400 400 383 304 243 196 158 128 103 4x4 -
7 1/2 0.042
18/20 400 400 400 400 335 274 226 187 155 W1.4xW1.4
18/18 400 400 400 400 335 274 225 186 155
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
86 www.newmill.com/digital-tools
3.0CFDC Composite Floor Deck Cellular

Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 3.0CFDC Cellular
PROPERTIES 5˝
Gage Thickness Cover Weight 3˝
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 5.32 12˝ 5˝
16/18 0.0598/0.0474 24 5.41
16/16 0.0598/0.0598 6.00 24˝ Coverage

Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 3.125 2.167 2.167 2.166 1.887 0.883 0.914 26446 27359 4491 1049 2079
16/18 40 3.180 2.441 2.441 2.440 2.048 1.169 1.097 27991 26278 4848 1285 2537
16/16 40 3.524 2.594 2.594 2.593 2.289 1.189 1.136 28485 27206 4848 1285 2537

Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16.
(psf) Single Double Triple Cantilever (ft3/ft2)
2. Web crippling design strengths* and maximum construction spans are
18/16 14 - 6 16 - 4 16 - 11 5 - 7
based on 2 1/2'' for end bearing and 5'' for interior bearing. Check web

Versa-Dek®
Long-Span Composite
5 16/18 42 14 - 11 16 - 2 16 - 7 5 - 6 0.292
crippling if minimums are not met.
16/16 15 - 1 16 - 3 16 - 10 5 - 7
Normal-Weight Concrete (145 pcf)

3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for


18/16 14 - 1 15 - 8 16 - 2 5 - 4
Composite Steel Floor Deck and the following construction loading:
5 1/2 16/18 48 14 - 6 15 - 6 15 - 11 5 - 3 0.333
● Deck self-weight and concrete weight plus worst-case of either a 150
16/16 14 - 8 15 - 7 16 - 1 5 - 4
lb. concentrated load or a 20 psf uniform load; or
18/16 13 - 8 15 - 1 15 - 7 5 - 2

Deep-Dek®
● Deck self-weight plus a 50 psf uniform construcon load, whichever
6 16/18 54 14 - 1 14 - 10 15 - 3 5 - 1 0.375
controls.
16/16 14 - 4 15 - 0 15 - 6 5 - 2
4. Concrete weights do not include weight of deck.
18/16 13 - 5 14 - 6 15 - 0 5 - 0
5. Deck profile has been accounted for in determining concrete
6 1/2 16/18 60 13 - 9 14 - 4 14 - 9 4 - 11 0.417
volumes. Deck and support deflections have not been included in
16/16 13 - 11 14 - 5 14 - 11 4 - 11
concrete volumes or weights.
18/16 13 - 1 14 - 0 14 - 6 4 - 10
7 16/18 66 0.458 6. Cantilever clear spans assume adjacent clear span is at least 3 times
13 - 6 13 - 10 14 - 3 4 - 9
16/16 longer than the cantilever clear span and no greater than spans
13 - 8 13 - 11 14 - 5 4 - 9
18/16 published above. Bearing width at perimeter support assumed to be 5''
12 - 10 13 - 7 14 - 0 4 - 8

Form Deck
7 1/2 16/18 73 0.500 minimum. Contact New Millennium otherwise.
13 - 2 13 - 4 13 - 10 4 - 7
16/16 13 - 5 13 - 6 14 - 0 4 - 8

SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire

Typical Fastener Layouts


Depth Gage Clear Span (ft - in) Welded Wire Area
NW Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)

(in) 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0 16 - 0 Fabric (in2/ft)


18/16 400 335 262 209 168 136 111 90 74 6x6 -
5 16/18 397 304 237 188 150 121 98 79 64 0.028
16/16 397 303 236 187 149 120 97 78 63 W1.4xW1.4
18/16 400 393 308 245 198 160 131 107 88 6x6 -
5 1/2 16/18 400 356 278 221 177 143 116 94 76 0.028
16/16 400 356 278 220 176 142 115 93 75 W1.4xW1.4
18/16 400 400 357 285 230 187 153 125 103 6x6 -
6 16/18 400 400 323 256 206 167 135 110 90 0.028
16/16 400 400 322 256 205 166 135 110 89 W1.4xW1.4
18/16 400 400 400 326 263 215 176 145 119
General Information
6x6 -
6 1/2 16/18 400 400 370 294 237 192 156 128 104 0.040
16/16 400 400 369 294 236 191 156 127 104 W2.0xW2.0
18/16 400 400 400 368 298 243 200 165 136 6x6 -
7 16/18 400 400 400 333 269 218 178 146 120 0.040
16/16 400 400 400 333 268 218 178 145 119 W2.0xW2.0
18/16 400 400 400 400 334 273 225 186 154 4x4 -
7 1/2 16/18 400 400 400 374 302 246 201 165 136 0.042
16/16 400 400 400 373 301 245 200 164 135 W1.4xW1.4

Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 87
3.0CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents

LIGHTWEIGHT CONCRETE
Composite Decks - Type 3.0CFDCA Cellular
PROPERTIES 5˝
Gage Thickness Cover Weight 3˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 3.45 12˝ 5˝
20/18 0.0358/0.0474 3.92
24
18/20 0.0474/0.0358 4.08 24˝ Coverage
Roof Deck

18/18 0.0474/0.0474 4.56


ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 50 1.936 1.449 1.449 1.443 1.154 0.567 0.627 16971 18786 2564 625 1246
20/18 50 2.187 1.551 1.551 1.544 1.307 0.569 0.675 17050 20206 2564 625 1246
18/20 50 2.310 1.816 1.816 1.815 1.388 0.851 0.812 25473 24301 4491 1049 2079
18/18 50 2.561 1.941 1.941 1.941 1.614 0.867 0.874 25970 26168 4491 1049 2079
CONSTRUCTION CLEAR SPANS
Composite Deck

Concrete Maximum Construction Concrete Notes:


Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft3/ft2)
accordance with SDI white paper ''Perforated Metal Deck Design with
20/20 14 - 1 14 - 11 15 - 5 5 - 1
Commentary''.
20/18 14 - 1 15 - 4 15 - 11 5 - 3
5 32 0.292 2. Web crippling design strengths* and maximum construction spans are
18/20 14 - 10 17 - 3 17 - 5 5 - 9
18/18 15 - 1 17 - 6 17 - 8 5 - 10 based on 2 1/2'' for end bearing and 5'' for interior bearing. Check web
20/20 13 - 5 14 - 3 14 - 10 4 - 11 crippling if minimums are not met.
20/18 13 - 5 14 - 9 15 - 3 5 - 1 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
5 1/2 37 0.333
18/20 14 - 5 16 - 8 16 - 10 5 - 7 Composite Steel Floor Deck and the following construction loading:
Lightweight Concrete (110 pcf)
Deep-Dek®
Long-Span Composite

18/18 14 - 8 16 - 10 17 - 2 5 - 8 ● Deck self-weight and concrete weight plus worst-case of either a 150
20/20 12 - 10 13 - 9 14 - 3 4 - 9 lb. concentrated load or a 20 psf uniform load; or
20/18 12 - 10 14 - 3 14 - 8 4 - 10 ● Deck self-weight plus a 50 psf uniform construcon load, whichever
6 41 0.375
18/20 14 - 1 16 - 0 16 - 3 5 - 5 controls.
18/18 14 - 3 16 - 3 16 - 8 5 - 6 4. Concrete weights do not include weight of deck.
20/20 12 - 4 13 - 3 13 - 9 4 - 7 5. Deck profile has been accounted for in determining concrete
Versa-Dek®

20/18 12 - 4 13 - 9 14 - 2 4 - 8 volumes. Deck and support deflections have not been included in
6 1/2 46 0.417
18/20 13 - 9 15 - 6 15 - 8 5 - 2 concrete volumes or weights.
18/18 13 - 11 15 - 8 16 - 3 5 - 5 6. Cantilever clear spans assume adjacent clear span is at least 3 times
20/20 11 - 11 12 - 10 13 - 4 4 - 5 longer than the cantilever clear span and no greater than spans
20/18 11 - 11 13 - 3 13 - 9 4 - 7
7 50 0.458 published above. Bearing width at perimeter support assumed to be 5''
18/20 13 - 5 15 - 0 15 - 2 5 - 0
minimum. Contact New Millennium otherwise.
18/18 13 - 7 15 - 2 15 - 8 5 - 2
20/20 11 - 6 12 - 6 12 - 11 4 - 3
20/18 11 - 6 12 - 7 13 - 4 4 - 5
7 1/2 55 0.500
Form Deck

18/20 13 - 2 14 - 6 14 - 9 4 - 11
18/18 13 - 4 14 - 9 15 - 3 5 - 1
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in) 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0 16 - 0 Fabric (in2/ft)
Lightweight Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)

20/20 325 250 195 155 125 101 82 67 55


20/18 325 249 195 155 124 101 82 67 54 6x6 -
Typical Fastener Layouts

5 0.028
18/20 400 328 259 208 168 132 106 86 71 W1.4xW1.4
18/18 400 328 258 207 168 132 106 86 71
20/20 381 293 229 183 147 119 97 80 65
20/18 380 292 229 182 147 119 97 79 65 6x6 -
5 1/2 0.028
18/20 400 384 304 244 198 163 135 112 92 W1.4xW1.4
18/18 400 384 303 243 198 162 134 112 92
20/20 400 338 266 212 171 139 114 93 77
20/18 400 338 265 211 170 138 113 93 76 6x6 -
6 0.028
18/20 400 400 351 283 230 189 157 131 110 W1.4xW1.4
18/18 400 400 351 282 230 189 157 131 109
20/20 400 387 304 242 196 160 131 108 89
20/18 400 386 303 242 195 159 130 107 88 6x6 -
6 1/2 0.040
18/20 400 400 400 324 264 218 181 151 127 W2.0xW2.0
General Information

18/18 400 400 400 323 263 217 180 150 126
20/20 400 400 343 274 222 181 149 123 101
20/18 400 400 343 274 222 181 148 122 101 6x6 -
7 0.040
18/20 400 400 400 366 299 247 205 172 144 W2.0xW2.0
18/18 400 400 400 366 299 246 205 171 144
20/20 400 400 384 307 249 204 167 138 114
20/18 400 400 384 307 249 203 167 138 114 4x4 -
7 1/2 0.042
18/20 400 400 400 400 335 277 231 193 163 W1.4xW1.4
18/18 400 400 400 400 335 277 230 193 162
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
88 www.newmill.com/digital-tools
3.0CFDCA Composite Floor Deck Cellular Acoustical

Table of Contents
LIGHTWEIGHT CONCRETE
Composite Decks - Type 3.0CFDCA Cellular
PROPERTIES 5˝
Gage Thickness Cover Weight 3˝
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 5.07 12˝ 5˝
16/18 0.0598/0.0474 24 5.24
16/16 0.0598/0.0598 5.75 24˝ Coverage

Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 2.828 2.056 2.056 2.056 1.782 0.883 0.902 26424 26998 4491 1049 2079
16/18 40 2.960 2.324 2.324 2.323 1.979 1.153 1.090 27626 26114 4848 1285 2537
16/16 40 3.227 2.460 2.460 2.459 2.163 1.173 1.121 28089 26838 4848 1285 2537

Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft3/ft2)
accordance with SDI white paper ''Perforated Metal Deck Design with
18/16 15 - 3 17 - 8 17 - 10 5 - 11
Commentary''.

Versa-Dek®
Long-Span Composite
5 16/18 32 15 - 8 17 - 7 18 - 0 6 - 0 0.292
2. Web crippling design strengths* and maximum construction spans are
16/16 15 - 10 17 - 7 18 - 2 6 - 0
based on 2 1/2'' for end bearing and 5'' for interior bearing. Check web
18/16 14 - 10 17 - 0 17 - 4 5 - 9
Lightweight Concrete (110 pcf)

crippling if minimums are not met.


5 1/2 16/18 37 15 - 3 16 - 11 17 - 4 5 - 9 0.333
3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
16/16 15 - 5 16 - 11 17 - 6 5 - 10
Composite Steel Floor Deck and the following construction loading:
18/16 14 - 5 16 - 5 16 - 11 5 - 7

Deep-Dek®
● Deck self-weight and concrete weight plus worst-case of either a 150
6 16/18 41 14 - 10 16 - 4 16 - 8 5 - 6 0.375
lb. concentrated load or a 20 psf uniform load; or
16/16 15 - 0 16 - 4 16 - 10 5 - 7
● Deck self-weight plus a 50 psf uniform construcon load, whichever
18/16 14 - 1 15 - 10 16 - 5 5 - 5
controls.
6 1/2 16/18 46 14 - 6 15 - 9 16 - 2 5 - 4 0.417
4. Concrete weights do not include weight of deck.
16/16 14 - 8 15 - 9 16 - 4 5 - 5
5. Deck profile has been accounted for in determining concrete
18/16 13 - 9 15 - 4 15 - 11 5 - 3
7 16/18 50 0.458 volumes. Deck and support deflections have not been included in
14 - 2 15 - 3 15 - 8 5 - 2
16/16 concrete volumes or weights.
14 - 4 15 - 3 15 - 10 5 - 3
18/16 6. Cantilever clear spans assume adjacent clear span is at least 3 times
13 - 6 14 - 11 15 - 5 5 - 1

Form Deck
7 1/2 16/18 55 0.500 longer than the cantilever clear span and no greater than spans
13 - 11 14 - 10 15 - 2 5 - 0
16/16 published above. Bearing width at perimeter support assumed to be 5''
14 - 1 14 - 10 15 - 4 5 - 1
minimum. Contact New Millennium otherwise.

SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire

Typical Fastener Layouts


Depth Gage Clear Span (ft - in) Welded Wire Area
LW Concrete (γc = 110 pcf, f'c = 3000 psi, n = 14)

(in) 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0 16 - 0 Fabric (in2/ft)


18/16 400 327 258 207 168 132 106 86 71 6x6 -
5 16/18 384 296 233 186 150 122 100 83 68 0.028
16/16 384 295 232 185 150 122 100 82 68 W1.4xW1.4
18/16 400 383 303 243 197 162 134 111 92 6x6 -
5 1/2 16/18 400 347 273 218 177 144 119 98 81 0.028
16/16 400 346 272 218 176 144 118 97 81 W1.4xW1.4
18/16 400 400 350 282 229 188 156 130 109 6x6 -
6 16/18 400 400 316 253 206 168 139 115 95 0.028
16/16 400 400 316 253 205 168 138 114 95 W1.4xW1.4
18/16 400 400 400 323 263 217 180 150 126
General Information
6x6 -
6 1/2 16/18 400 400 363 291 236 194 160 133 111 0.040
16/16 400 400 362 290 236 193 159 132 110 W2.0xW2.0
18/16 400 400 400 365 298 246 204 171 143 6x6 -
7 16/18 400 400 400 330 268 220 182 152 127 0.040
16/16 400 400 400 329 268 220 182 151 126 W2.0xW2.0
18/16 400 400 400 400 334 276 230 192 162 4x4 -
7 1/2 16/18 400 400 400 370 302 248 206 171 143 0.042
16/16 400 400 400 370 301 248 205 171 143 W1.4xW1.4

Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 89
3.0CFDCA Composite Floor Deck Cellular Acoustical
Table of Contents

NORMAL-WEIGHT CONCRETE
Composite Decks - Type 3.0CFDCA Cellular
PROPERTIES 5˝
Gage Thickness Cover Weight 3˝
(Hat/Pan) (in) (in) (psf)
20/20 0.0358/0.0358 3.45 12˝ 5˝
20/18 0.0358/0.0474 3.92
24
18/20 0.0474/0.0358 4.08 24˝ Coverage
Roof Deck

18/18 0.0474/0.0474 4.56


ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
20/20 50 1.936 1.449 1.449 1.443 1.154 0.567 0.627 16971 18786 2564 625 1246
20/18 50 2.187 1.551 1.551 1.544 1.307 0.569 0.675 17050 20206 2564 625 1246
18/20 50 2.310 1.816 1.816 1.815 1.388 0.851 0.812 25473 24301 4491 1049 2079
18/18 50 2.561 1.941 1.941 1.941 1.614 0.867 0.874 25970 26168 4491 1049 2079
CONSTRUCTION CLEAR SPANS
Composite Deck

Concrete Maximum Construction Concrete Notes:


Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft3/ft2)
accordance with SDI white paper ''Perforated Metal Deck Design with
20/20 12 - 9 13 - 8 14 - 1 4 - 8
Commentary''.
20/18 12 - 9 14 - 1 14 - 7 4 - 10
5 42 0.292 2. Web crippling design strengths* and maximum construction spans are
18/20 14 - 0 15 - 11 16 - 1 5 - 4
18/18 14 - 2 16 - 1 16 - 7 5 - 6 based on 2 1/2'' for end bearing and 5'' for interior bearing. Check web
20/20 12 - 1 13 - 1 13 - 6 4 - 6 crippling if minimums are not met.
20/18 12 - 1 13 - 6 13 - 11 4 - 7 3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
Normal-Weight Concrete (145 pcf)

5 1/2 48 0.333
18/20 13 - 7 15 - 2 15 - 5 5 - 1 Composite Steel Floor Deck and the following construction loading:
Deep-Dek®
Long-Span Composite

18/18 13 - 9 15 - 5 15 - 11 5 - 3 ● Deck self-weight and concrete weight plus worst-case of either a 150
20/20 11 - 7 12 - 6 12 - 11 4 - 3 lb. concentrated load or a 20 psf uniform load; or
20/18 11 - 7 12 - 8 13 - 4 4 - 5 ● Deck self-weight plus a 50 psf uniform construcon load, whichever
6 54 0.375
18/20 13 - 2 14 - 7 14 - 10 4 - 11 controls.
18/18 13 - 4 14 - 9 15 - 4 5 - 1 4. Concrete weights do not include weight of deck.
20/20 11 - 2 11 - 10 12 - 6 4 - 2 5. Deck profile has been accounted for in determining concrete
Versa-Dek®

20/18 11 - 1 11 - 9 12 - 10 4 - 3 volumes. Deck and support deflections have not been included in
6 1/2 60 0.417
18/20 12 - 10 14 - 0 14 - 3 4 - 9 concrete volumes or weights.
18/18 13 - 1 14 - 3 14 - 9 4 - 11 6. Cantilever clear spans assume adjacent clear span is at least 3 times
20/20 10 - 9 11 - 2 12 - 0 4 - 0 longer than the cantilever clear span and no greater than spans
20/18 10 - 9 11 - 2 12 - 5 4 - 1
7 66 0.458 published above. Bearing width at perimeter support assumed to be 5''
18/20 12 - 7 13 - 6 13 - 9 4 - 7
minimum. Contact New Millennium otherwise.
18/18 12 - 9 13 - 9 14 - 3 4 - 9
20/20 10 - 4 10 - 6 11 - 7 3 - 10
20/18 10 - 4 10 - 6 11 - 8 3 - 10
7 1/2 73 0.500
Form Deck

18/20 12 - 4 13 - 1 13 - 5 4 - 5
18/18 12 - 6 13 - 4 13 - 9 4 - 7
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire
Depth Gage Clear Span (ft - in) Welded Wire Area
(in2/ft)
Normal-Weight Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)

(in) 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0 16 - 0 Fabric
20/20 332 252 196 154 122 97 77 62 49
20/18 331 252 195 153 122 97 77 61 48 6x6 -
Typical Fastener Layouts

5 0.028
18/20 400 336 264 210 169 137 112 91 75 W1.4xW1.4
18/18 400 336 263 209 168 137 111 91 74
20/20 388 296 230 181 144 115 92 73 58
20/18 388 295 229 181 143 114 91 73 58 6x6 -
5 1/2 0.028
18/20 400 394 309 247 199 162 132 108 89 W1.4xW1.4
18/18 400 394 309 246 198 161 132 108 88
20/20 400 342 266 210 167 134 107 86 69
20/18 400 342 266 209 167 133 107 86 68 6x6 -
6 0.028
18/20 400 400 358 286 231 188 154 127 104 W1.4xW1.4
18/18 400 400 358 285 230 188 154 126 104
20/20 400 391 304 240 192 154 124 100 80
20/18 400 390 304 240 191 153 123 99 79 6x6 -
6 1/2 0.040
18/20 400 400 400 327 264 216 177 146 121 W2.0xW2.0
General Information

18/18 400 400 400 326 264 215 177 146 120
20/20 400 400 344 272 217 175 141 114 92
20/18 400 400 343 271 217 174 141 113 91 6x6 -
7 0.040
18/20 400 400 400 370 299 245 201 166 138 W2.0xW2.0
18/18 400 400 400 369 299 244 201 166 137
20/20 400 400 384 304 243 196 159 128 104
20/18 400 400 384 304 243 196 158 128 103 4x4 -
7 1/2 0.042
18/20 400 400 400 400 335 274 226 187 155 W1.4xW1.4
18/18 400 400 400 400 335 274 226 187 155
Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
90 www.newmill.com/digital-tools
3.0CFDCA Composite Floor Deck Cellular Acoustical

Table of Contents
NORMAL-WEIGHT CONCRETE
Composite Decks - Type 3.0CFDCA Cellular
PROPERTIES 5˝
Gage Thickness Cover Weight 3˝
(Hat/Pan) (in) (in) (psf)
18/16 0.0474/0.0598 5.07 12˝ 5˝
16/18 0.0598/0.0474 24 5.24
16/16 0.0598/0.0598 5.75 24˝ Coverage

Roof Deck
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy As ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in2/ft) (in4/ft) 4
(in /ft)
4
(in /ft)
4
(in /ft)
3
(in /ft)
3
(in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
18/16 50 2.828 2.056 2.056 2.056 1.782 0.883 0.902 26424 26998 4491 1049 2079
16/18 40 2.960 2.324 2.324 2.323 1.979 1.153 1.090 27626 26114 4848 1285 2537
16/16 40 3.227 2.460 2.460 2.459 2.163 1.173 1.121 28089 26838 4848 1285 2537

Composite Deck
CONSTRUCTION CLEAR SPANS
Concrete Maximum Construction Concrete Notes:
Total Slab
Gage Weight Clear Span (ft - in) Volume 1. Section properties and resistance spot weld strength are calculated in
Depth (in) accordance with the AISI S100-16, with perforation modifiers applied in
(psf) Single Double Triple Cantilever (ft3/ft2)
accordance with SDI white paper ''Perforated Metal Deck Design with
18/16 14 - 4 16 - 3 16 - 10 5 - 7
Commentary''.

Versa-Dek®
Long-Span Composite
5 16/18 42 14 - 9 16 - 2 16 - 7 5 - 6 0.292
2. Web crippling design strengths* and maximum construction spans are
16/16 14 - 11 16 - 2 16 - 9 5 - 7
Normal-Weight Concrete (145 pcf)

based on 2 1/2'' for end bearing and 5'' for interior bearing. Check web
18/16 13 - 11 15 - 7 16 - 1 5 - 4
crippling if minimums are not met.
5 1/2 16/18 48 14 - 4 15 - 6 15 - 10 5 - 3 0.333
3. Maximum construction spans are based on ANSI/SDI C-2017 Standard for
16/16 14 - 6 15 - 6 16 - 0 5 - 4
Composite Steel Floor Deck and the following construction loading:
18/16 13 - 6 15 - 0 15 - 6 5 - 2

Deep-Dek®
● Deck self-weight and concrete weight plus worst-case of either a 150
6 16/18 54 13 - 11 14 - 10 15 - 3 5 - 1 0.375
lb. concentrated load or a 20 psf uniform load; or
16/16 14 - 1 14 - 11 15 - 5 5 - 1
● Deck self-weight plus a 50 psf uniform construcon load, whichever
18/16 13 - 3 14 - 5 14 - 11 4 - 11
controls.
6 1/2 16/18 60 13 - 7 14 - 4 14 - 9 4 - 11 0.417
4. Concrete weights do not include weight of deck.
16/16 13 - 9 14 - 4 14 - 10 4 - 11
5. Deck profile has been accounted for in determining concrete
18/16 12 - 11 13 - 11 14 - 5 4 - 9
7 16/18 66 0.458 volumes. Deck and support deflections have not been included in
13 - 4 13 - 10 14 - 3 4 - 9
16/16 concrete volumes or weights.
13 - 6 13 - 10 14 - 4 4 - 9
18/16 6. Cantilever clear spans assume adjacent clear span is at least 3 times
12 - 8 13 - 6 13 - 11 4 - 7

Form Deck
7 1/2 16/18 73 0.500 longer than the cantilever clear span and no greater than spans
13 - 1 13 - 4 13 - 10 4 - 7
16/16 published above. Bearing width at perimeter support assumed to be 5''
13 - 3 13 - 5 13 - 11 4 - 7
minimum. Contact New Millennium otherwise.

SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS AND MINIMUM SDI SLAB REINFORCEMENT
Total Slab Allowable Superimposed Uniform Load (psf) Recommended Wire

Typical Fastener Layouts


Depth Gage Clear Span (ft - in) Welded Wire Area
NW Concrete (γc = 145 pcf, f'c = 3000 psi, n = 9)

(in) 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0 16 - 0 Fabric (in2/ft)


18/16 400 335 263 209 168 136 111 90 74 6x6 -
5 16/18 397 304 237 188 150 121 98 79 64 0.028
16/16 397 303 237 187 150 120 97 78 63 W1.4xW1.4
18/16 400 393 308 246 198 161 131 107 88 6x6 -
5 1/2 16/18 400 357 279 221 177 143 116 94 76 0.028
16/16 400 356 278 220 177 142 115 94 76 W1.4xW1.4
18/16 400 400 357 285 230 187 153 126 103 6x6 -
6 16/18 400 400 323 257 206 167 136 110 90 0.028
16/16 400 400 323 256 206 166 135 110 89 W1.4xW1.4
18/16 400 400 400 326 263 215 176 145 120
General Information
6x6 -
6 1/2 16/18 400 400 370 294 237 192 157 128 104 0.040
16/16 400 400 369 294 236 192 156 127 104 W2.0xW2.0
18/16 400 400 400 369 298 244 200 165 137 6x6 -
7 16/18 400 400 400 334 269 218 178 146 120 0.040
16/16 400 400 400 333 268 218 178 146 119 W2.0xW2.0
18/16 400 400 400 400 334 273 225 186 154 4x4 -
7 1/2 16/18 400 400 400 374 302 246 201 165 136 0.042
16/16 400 400 400 374 301 245 201 165 135 W1.4xW1.4

Notes: 7. Welded wire fabric shown in the table above is the SDI minimum required for temperature and shrinkage (0.00075 x concrete area above top of deck).
8. Allowable Superimposed Uniform Loads shown in table above are based on the following criteria:
Code of Standard Practice

● Unfactored service level loads, determined using SDI design method per ANSI/SDI C-2017 Standard for Composite Steel Floor Deck-Slabs.
● Single span condions without negave bending reinforcing over supports.
● The presence of shear studs have not been considered, design strength may be increased if shear studs are used.
● Slab deflecon is limited to minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 91
Long-Span
Table of Contents

Composite Deck
Roof Deck

Versa-Dek® Composite
Versa-Dek® Composite is a versatile, long-span composite floor system, ideal for
multi-story construction. It’s ‘dovetail’ profiling keys to concrete to create a superior
Composite Deck

composite bond. Because more concrete is placed in the bottom of the deck, the
total slab thickness needed to achieve fire ratings is the shallowest available.
Deep-Dek®
Long-Span Composite
Versa-Dek®



3 21 ˝

24˝ Coverage 24˝ Coverage


Form Deck

Versa-Dek® 2.0 Composite Versa-Dek® 3.5 Composite

Advantages
Space optimization
• Low-profile slabs as thin as 4-inches maximize
Typical Fastener Layouts

ceiling height and reduce building height


• Spans up to 28 ft. create open interior spaces
• Relocatable Versa-WedgeTM hangers suspend
lighting and MEP components Download the Versa-Dek®
Composite Design Guide
Efficient construction
• Integrates with any beam or wall construction
INTERACTIVE PDF
VERSION 2.2

• Noncombustible — lower insurance premiums


General Information

• Not susceptible to termites, mold or dry-rot


• Traditional means and methods
• No specialized equipment or training
• Allows core drilling flexibility

Approvals and standards Design Guide


Versa-Dek® Composite
• ICC ES Evaluation Reports LONG-SPAN COMPOSITE SYSTEMS
Code of Standard Practice

ESR-2635 and ESR-3477


• Compliant with International
Building Code (IBC)
• Designed in accordance with
AISI S100 and ANSI/SDI C newmill.com/design-tools/load-tables.html
Table of Contents
Versa-Dek® Composite and Deep-Dek® Composite long-span composite floor
systems are engineered and manufactured to improve the cost efficiency and
performance of multi-story building designs. The optimal combination of steel
and concrete creates wide-open spans uninterrupted by support columns.

Roof Deck
Deep-Dek® Composite
Deep-Dek® Composite is our longest spanning composite floor option. It integrates
concrete and deep-ribbed deck profiles with custom side lap treatments to create

Composite Deck
a unique composite bond. The system is an excellent fit in structures demanding
combinations of shallow depth, high-load capacity and stringent serviceability demands.

Versa-Dek®
Long-Span Composite
Deep-Dek®
7 85 ˝ 7 85 ˝ 7 85 ˝
4 85 ˝ 4 85 ˝ 4 85 ˝ 6 18 ˝ 6 18 ˝ 6 18 ˝

12˝ Coverage
12˝ Coverage
12˝ Coverage 12˝ Coverage
12˝ Coverage
12˝ Coverage 12˝ Coverage
12˝ Coverage
12˝ Coverage

Form Deck
Deep-Dek® Composite 4.5 Deep-Dek® Composite 6.0 Deep-Dek® Composite 7.5

Advantages
Space optimization

Typical Fastener Layouts


• Low-profile slabs as thin as 7.625-inches maximize
ceiling height and reduce building height
• Spans up to 36 ft. create open interior spaces
Download the Deep-Dek®
Efficient construction
Composite Design Guide
• Up to 40% less weight than comparably
utilized cast-in-place concrete INTERACTIVE PDF
VERSION 2.1

• Quick installation including optional field


panelized lift-in-place sections
General Information

• Integrates with any structural system

Approvals and standards


• Up to 2-hr. UL tested fire-rated
assemblies – Options for 3- and
Design Guide
4-hr. ratings Deep-Dek® Composite
• Compliant with International LONG-SPAN COMPOSITE SYSTEMS
Code of Standard Practice

Building Code (IBC) –


ICC ESR-2839 –
LA County LARR-25758
• Proven conformance with
AISC vibration design standard newmill.com/design-tools/load-tables.html

93
Long-Span Composite
Code of Standard Practice General Information Typical Fastener Layouts Form Deck Composite Deck Roof Deck Table of Contents
Versa-Dek® Deep-Dek®

Form Deck
Table of Contents
Form deck is used extensively in floor construction as an economical form
to support concrete slabs during construction. Certain deck types may
eliminate the need for expensive temporary shoring. Click on the links
below to view load tables.

Roof Deck
0.6 and 1.0 Form Deck................................................................................... 96 – 99

Composite Deck
9/16-inch and 1-inch form deck,
standard and vented options available

EHD-Dek...........................................................................................................100 – 101
1 5/16-inch form deck, standard
and vented options available

Versa-Dek®
Long-Span Composite
1.5 Form Deck............................................................................................... 102 – 105
1.5-inch form deck with standard,

Deep-Dek®
interlocking, and vented options available

2.0 Form Deck................................................................................................106 – 107


2-inch form deck

Form Deck
3.0 Form Deck............................................................................................... 108 – 109
3-inch form deck

Typical Fastener Layouts


General Information
Code of Standard Practice

newmill.com 95
0.6FD, 0.6FDV Form Deck
Table of Contents

LIGHTWEIGHT CONCRETE
Form Decks - Types 0.6FD, 0.6FDV
PROPERTIES
Thickness Cover Weight
Gage 3
4
˝ 143 ˝ 2 12˝
(in) (in) (psf)
9
28 0.0149 0.75 16˝
26 0.0179 0.90
35 35˝ Coverage ICC-ESApproved
ICC-ES APPROVED-
24 0.0238 1.19
REFERtoTOESR-3818
Refer ESR-3818
Roof Deck

22 0.0295 1.48
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
28 60 0.011 0.011 0.011 0.011 0.033 0.034 1190 1236 1534 583 910
26 60 0.013 0.013 0.013 0.013 0.042 0.044 1517 1576 1839 811 1278
24 60 0.018 0.018 0.018 0.018 0.060 0.060 2144 2144 2435 1352 2160
22 60 0.022 0.022 0.022 0.022 0.073 0.073 2631 2631 3006 1984 3201
CONSTRUCTION CLEAR SPANS
Composite Deck

Total Slab Concrete Maximum Construction Conc. Notes:


Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
28 2 - 3 2 - 9 2 - 9 0 - 7 2. Web crippling design strengths* and maximum construction
26 2 - 9 3 - 4 3 - 5 0 - 9 spans are based on 1 1/2'' for end bearing and 3'' for interior
2 1/2 20 0.185 bearing. Check web crippling if minimums are not met.
24 3 - 9 4 - 5 4 - 6 1 - 1
22 4 - 5 5 - 3 5 - 4 1 - 3 3. Maximum construction spans are based on ANSI/SDI
28 2 - 2 2 - 8 2 - 8 0 - 7 NC-2017 Standard for Non-Composite Steel Floor Deck
26 2 - 8 3 - 3 3 - 3 0 - 9 and the following construction loading:
3 25 0.227
Deep-Dek®

● Deck self-weight and concrete weight plus worst-case of


Long-Span Composite

24 3 - 7 4 - 3 4 - 4 1 - 1
Lightweight Concrete (110 psf)

22 4 - 1 5 - 0 5 - 1 1 - 3 either a 150 lb. concentrated load or a 20 psf


28 2 - 2 2 - 7 2 - 7 0 - 7 uniform load; or
26 2 - 7 3 - 2 3 - 2 0 - 9 ● Deck self-weight plus a 50 psf uniform
3 1/2 30 0.269
24 3 - 6 4 - 2 4 - 2 1 - 0 construction load, whichever controls.
22 3 - 11 4 - 10 4 - 10 1 - 3 4. Concrete weights do not include weight of deck.
Versa-Dek®

28 2 - 1 2 - 6 2 - 6 0 - 7 5. Deck profile has been accounted for in determining concrete


26 2 - 7 3 - 1 3 - 1 0 - 9 volumes. Deck and support deflections have not been
4 34 0.310
24 3 - 4 4 - 0 4 - 1 1 - 0 included in concrete volumes or weights.
22 3 - 9 4 - 8 4 - 7 1 - 3 6. Cantilever clear spans assume adjacent clear span is at least
28 2 - 0 2 - 5 2 - 6 0 - 7 3 times longer than the cantilever clear span and no greater
26 2 - 6 3 - 0 3 - 0 0 - 9 than spans shown. Bearing width at perimeter support
4 1/2 39 0.352
24 3 - 3 3 - 11 3 - 11 1 - 0 assumed to be 3'' minimum. Contact New Millennium
22 3 - 7 4 - 6 4 - 5 1 - 3 otherwise.
Form Deck

28 2 - 0 2 - 5 2 - 5 0 - 7
26 2 - 5 2 - 11 2 - 11 0 - 9
5 43 0.394
24 3 - 2 3 - 9 3 - 10 1 - 0
22 3 - 5 4 - 5 4 - 3 1 - 2
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
LWC (γc = 110 pcf, f'c = 3000 psi, n = 14, Fys = 60000 psi)

Depth, h (Mesh or 2 Clear Span (ft - in)


(in /ft)
Typical Fastener Layouts

(in) Deformed Bars) 2 - 0 2 - 6 2 - 9 3 - 0 3 - 3 3 - 6 4 - 0 4 - 6 5 - 0


6x6 - W2.9xW2.9 0.058 400 264 218 183 156 135 103 81 66
2 1/2 4x4 - W2.0xW2.0 0.060 400 272 225 189 161 139 106 84 68
6x6 - W4.0xW4.0 0.080 400 355 294 247 210 181 139 110 89
4x4 - W2.0xW2.0 0.060 400 346 286 241 205 177 135 107 87
3 6x6 - W4.0xW4.0 0.080 400 400 375 315 269 232 177 140 114
4x4 - W2.9xW2.9 0.087 400 400 400 341 290 250 192 152 123
6x6 - W4.0xW4.0 0.080 400 400 400 400 400 400 370 292 237
3 1/2 4x4 - W2.9xW2.9 0.087 400 400 400 400 400 400 400 323 261
4x4 - W4.0xW4.0 0.120 400 400 400 400 400 400 400 376 338
4x4 - W2.9xW2.9 0.087 400 400 400 400 400 400 400 395 320
4 4x4 - W4.0xW4.0 0.120 400 400 400 400 400 400 400 400 400
General Information

#3 @ 9'' o.c. 0.147 400 400 400 400 400 400 400 400 400
4x4 - W4.0xW4.0 0.120 400 400 400 400 400 400 400 400 400
4 1/2 #3 @ 9'' o.c. 0.147 400 400 400 400 400 400 400 400 400
#4 @ 12'' o.c. 0.196 400 400 400 400 400 400 400 400 400
4x4 - W4.0xW4.0 0.120 400 400 400 400 400 400 400 400 400
5 #3 @ 9'' o.c. 0.147 400 400 400 400 400 400 400 400 400
#4 @ 12'' o.c. 0.196 400 400 400 400 400 400 400 400 400
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive
Code of Standard Practice

steel rests on deck and negative steel cover = 3/4''.


● Galvanized deck. If non-galvanized deck or temporary shoring is used, the weight of the slab must be deducted from the uniform loads.
● End span of three span condion and ACI moment coefficients.
● Slab deflecon is limited to a minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
96 www.newmill.com/digital-tools
0.6FD, 0.6FDV Form Deck

Table of Contents
Form Decks - Types 0.6FD, 0.6FDV
NORMAL-WEIGHT CONCRETE

PROPERTIES
Thickness Cover Weight
Gage 3
4
˝ 143 ˝ 2 12˝
(in) (in) (psf)
9
28 0.0149 0.75 16˝
26 0.0179 0.90
35 35˝ Coverage ICC-ESApproved
ICC-ES APPROVED-
24 0.0238 1.19
REFERto
Refer TOESR-3818
ESR-3818

Roof Deck
22 0.0295 1.48
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
28 60 0.011 0.011 0.011 0.011 0.033 0.034 1190 1236 1534 583 910
26 60 0.013 0.013 0.013 0.013 0.042 0.044 1517 1576 1839 811 1278
24 60 0.018 0.018 0.018 0.018 0.060 0.060 2144 2144 2435 1352 2160
22 60 0.022 0.022 0.022 0.022 0.073 0.073 2631 2631 3006 1984 3201
CONSTRUCTION CLEAR SPANS

Composite Deck
Total Slab Concrete Maximum Construction Conc. Notes:
Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
28 2 - 2 2 - 7 2 - 8 0 - 7 2. Web crippling design strengths* and maximum construction
26 2 - 8 3 - 2 3 - 3 0 - 9 spans are based on 1 1/2'' for end bearing and 3'' for interior
2 1/2 27 0.185 bearing. Check web crippling if minimums are not met.
24 3 - 6 4 - 3 4 - 3 1 - 0
22 4 - 0 4 - 11 5 - 0 1 - 3 3. Maximum construction spans are based on ANSI/SDI
28 2 - 1 2 - 6 2 - 7 0 - 7 NC-2017 Standard for Non-Composite Steel Floor Deck
26 2 - 7 3 - 1 3 - 1 0 - 9 and the following construction loading:
3 33 0.227

Versa-Dek®
● Deck self-weight and concrete weight plus worst-case of
Normal-Weight Concrete (145 psf)

Long-Span Composite
24 3 - 5 4 - 0 4 - 1 1 - 0
22 3 - 9 4 - 9 4 - 8 1 - 3 either a 150 lb. concentrated load or a 20 psf
28 2 - 0 2 - 5 2 - 6 0 - 7 uniform load; or
26 2 - 6 3 - 0 3 - 0 0 - 9 ● Deck self-weight plus a 50 psf uniform
3 1/2 39 0.269
24 3 - 3 3 - 11 3 - 11 1 - 0 construction load, whichever controls.
22 3 - 7 4 - 6 4 - 5 1 - 3 4. Concrete weights do not include weight of deck.

Deep-Dek®
28 2 - 0 2 - 5 2 - 5 0 - 7 5. Deck profile has been accounted for in determining concrete
26 2 - 5 2 - 11 2 - 11 0 - 9 volumes. Deck and support deflections have not been
4 45 0.310
24 3 - 2 3 - 9 3 - 9 1 - 0 included in concrete volumes or weights.
22 3 - 5 4 - 4 4 - 3 1 - 2 6. Cantilever clear spans assume adjacent clear span is at least
28 1 - 11 2 - 4 2 - 4 0 - 7 3 times longer than the cantilever clear span and no greater
26 2 - 4 2 - 10 2 - 10 0 - 9 than spans shown. Bearing width at perimeter support
4 1/2 51 0.352
24 3 - 1 3 - 7 3 - 8 1 - 0 assumed to be 3'' minimum. Contact New Millennium
22 3 - 3 4 - 2 4 - 1 1 - 2 otherwise.

Form Deck
28 1 - 11 2 - 3 2 - 3 0 - 7
26 2 - 3 2 - 9 2 - 9 0 - 9
5 57 0.394
24 2 - 11 3 - 6 3 - 7 0 - 11
22 3 - 2 4 - 1 3 - 11 1 - 2
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
NWC (γc = 145 pcf, f'c = 3000 psi, n = 9, Fys = 60000 psi)

Depth, h (Mesh or 2 Clear Span (ft - in)


(in /ft)

Typical Fastener Layouts


(in) Deformed Bars) 2 - 0 2 - 6 2 - 9 3 - 0 3 - 3 3 - 6 4 - 0 4 - 6 5 - 0
6x6 - W2.9xW2.9 0.058 400 264 218 183 156 135 103 81 66
2 1/2 4x4 - W2.0xW2.0 0.060 400 272 225 189 161 139 106 84 68
6x6 - W4.0xW4.0 0.080 400 355 294 247 210 181 139 110 89
4x4 - W2.0xW2.0 0.060 400 346 286 241 205 177 135 107 87
3 6x6 - W4.0xW4.0 0.080 400 400 375 315 269 232 177 140 114
4x4 - W2.9xW2.9 0.087 400 400 400 341 290 250 192 152 123
6x6 - W4.0xW4.0 0.080 400 400 400 400 400 400 370 292 237
3 1/2 4x4 - W2.9xW2.9 0.087 400 400 400 400 400 400 400 323 261
4x4 - W4.0xW4.0 0.120 400 400 400 400 400 400 400 400 342
4x4 - W2.9xW2.9 0.087 400 400 400 400 400 400 400 395 320
4 4x4 - W4.0xW4.0 0.120 400 400 400 400 400 400 400 400 400
General Information
#3 @ 9'' o.c. 0.147 400 400 400 400 400 400 400 400 400
4x4 - W4.0xW4.0 0.120 400 400 400 400 400 400 400 400 400
4 1/2 #3 @ 9'' o.c. 0.147 400 400 400 400 400 400 400 400 400
#4 @ 12'' o.c. 0.196 400 400 400 400 400 400 400 400 400
4x4 - W4.0xW4.0 0.120 400 400 400 400 400 400 400 400 400
5 #3 @ 9'' o.c. 0.147 400 400 400 400 400 400 400 400 400
#4 @ 12'' o.c. 0.196 400 400 400 400 400 400 400 400 400
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive
Code of Standard Practice

steel rests on deck and negative steel cover = 3/4''.


● Galvanized deck. If non-galvanized deck or temporary shoring is used, the weight of the slab must be deducted from the uniform loads.
● End span of three span condion and ACI moment coefficients.
● Slab deflecon is limited to a minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 97
1.0FD, 1.0FDV Form Deck
Table of Contents

LIGHTWEIGHT CONCRETE
Form Decks - Types 1.0FD, 1.0FDV
PROPERTIES
Thickness Cover Weight 181 ˝ 4˝
Gage 2 87˝
(in) (in) (psf)
26 0.0179 0.94 1˝
24 0.0238 1.24
36 36˝ Coverage ICC-ES APPROVED
ICC-ES Approved -
22 0.0295 1.54
REFER TOESR-3818
Refer to ESR-3818
Roof Deck

20 0.0358 1.87
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
26 60 0.042 0.042 0.041 0.041 0.068 0.071 2428 2547 1663 466 828
24 60 0.056 0.056 0.056 0.056 0.098 0.105 3518 3782 2739 789 1422
22 60 0.070 0.070 0.070 0.070 0.129 0.132 4631 4744 3388 1169 2126
20 60 0.085 0.085 0.085 0.085 0.160 0.160 5749 5749 4101 1665 3047
CONSTRUCTION CLEAR SPANS
Composite Deck

Total Slab Concrete Maximum Construction Conc. Notes:


Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
26 4 - 2 5 - 0 5 - 1 1 - 3 2. Web crippling design strengths* and maximum construction
24 5 - 8 6 - 9 6 - 10 1 - 10 spans are based on 1 1/2'' for end bearing and 3'' for interior
2 1/2 18 0.167 bearing. Check web crippling if minimums are not met.
22 6 - 8 7 - 10 8 - 1 2 - 3
20 7 - 1 8 - 7 8 - 10 2 - 8 3. Maximum construction spans are based on ANSI/SDI
26 4 - 0 4 - 10 4 - 11 1 - 3 NC-2017 Standard for Non-Composite Steel Floor Deck
24 5 - 5 6 - 5 6 - 6 1 - 9 and the following construction loading:
3 23 0.209
Deep-Dek®

● Deck self-weight and concrete weight plus worst-case of


Long-Span Composite

22 6 - 3 7 - 10 7 - 9 2 - 2
Lightweight Concrete (110 psf)

20 6 - 8 8 - 7 8 - 3 2 - 7 either a 150 lb. concentrated load or a 20 psf


26 3 - 11 4 - 8 4 - 8 1 - 3 uniform load; or
24 5 - 2 6 - 2 6 - 3 1 - 9 ● Deck self-weight plus a 50 psf uniform
3 1/2 28 0.250
22 5 - 11 7 - 6 7 - 4 2 - 2 construction load, whichever controls.
20 6 - 3 8 - 5 7 - 9 2 - 6 4. Concrete weights do not include weight of deck.
Versa-Dek®

26 3 - 9 4 - 6 4 - 6 1 - 2 5. Deck profile has been accounted for in determining concrete


24 5 - 0 5 - 11 6 - 0 1 - 9 volumes. Deck and support deflections have not been
4 32 0.292
22 5 - 7 7 - 2 6 - 11 2 - 1 included in concrete volumes or weights.
20 6 - 0 8 - 0 7 - 5 2 - 5 6. Cantilever clear spans assume adjacent clear span is at least
26 3 - 8 4 - 4 4 - 5 1 - 2 3 times longer than the cantilever clear span and no greater
24 4 - 10 5 - 8 5 - 9 1 - 8 than spans shown. Bearing width at perimeter support
4 1/2 37 0.334
22 5 - 5 6 - 11 6 - 8 2 - 0 assumed to be 3'' minimum. Contact New Millennium
20 5 - 9 7 - 8 7 - 1 2 - 5 otherwise.
Form Deck

26 3 - 7 4 - 2 4 - 3 1 - 2
24 4 - 8 5 - 6 5 - 7 1 - 8
5 41 0.375
22 5 - 2 6 - 8 6 - 5 2 - 0
20 5 - 6 7 - 5 6 - 10 2 - 4
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
LWC (γc = 110 pcf, f'c = 3000 psi, n = 14, Fys = 60000 psi)

Depth, h (Mesh or 2 Clear Span (ft - in)


(in /ft)
Typical Fastener Layouts

(in) Deformed Bars) 3 - 0 4 - 0 4 - 6 5 - 0 5 - 6 6 - 0 6 - 6 7 - 0 8 - 0


6x6 - W2.9xW2.9 0.058 139 78 62 50 41 35 30 26 20
2 1/2 4x4 - W2.0xW2.0 0.060 144 81 64 52 43 36 31 26 20
6x6 - W4.0xW4.0 0.080 186 105 83 67 55 47 40 34 26
6x6 - W2.9xW2.9 0.058 189 106 84 68 56 47 40 35 27
3 4x4 - W2.0xW2.0 0.060 195 110 87 70 58 49 42 36 27
6x6 - W4.0xW4.0 0.080 255 143 113 92 76 64 54 47 36
6x6 - W4.0xW4.0 0.080 400 359 284 230 190 160 136 117 90
3 1/2 4x4 - W2.9xW2.9 0.087 400 392 310 251 207 174 148 128 98
4x4 - W4.0xW4.0 0.120 400 391 347 313 275 231 197 169 130
6x6 - W4.0xW4.0 0.080 400 400 345 279 231 194 165 142 109
4 4x4 - W2.9xW2.9 0.087 400 400 376 305 252 212 180 155 119
General Information

4x4 - W4.0xW4.0 0.120 400 400 400 391 341 287 244 211 161
4x4 - W2.9xW2.9 0.087 400 400 400 359 296 249 212 183 140
4 1/2 4x4 - W4.0xW4.0 0.120 400 400 400 400 400 338 288 249 190
#3 @ 9'' o.c. 0.147 400 400 400 400 400 400 343 296 226
4x4 - W4.0xW4.0 0.120 400 400 400 400 400 390 332 287 219
5 #3 @ 9'' o.c. 0.147 400 400 400 400 400 400 397 342 262
#4 @ 12'' o.c. 0.196 400 400 400 400 400 400 400 400 339
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive
Code of Standard Practice

steel rests on deck and negative steel cover = 3/4''.


● Galvanized deck. If non-galvanized deck or temporary shoring is used, the weight of the slab must be deducted from the uniform loads.
● End span of three span condion and ACI moment coefficients.
● Slab deflecon is limited to a minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
98 www.newmill.com/digital-tools
1.0FD, 1.0FDV Form Deck

Table of Contents
Form Decks - Types 1.0FD, 1.0FDV
NORMAL-WEIGHT CONCRETE

PROPERTIES
Thickness Cover Weight 4˝
Gage 181 ˝ 2 87˝
(in) (in) (psf)
26 0.0179 0.94 1˝
24 0.0238 1.24
36
36˝ Coverage ICC-ES Approved
ICC-ES APPROVED-
22 0.0295 1.54
0.0358 1.87
REFERto
Refer TOESR-3818
ESR-3818

Roof Deck
20
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
26 60 0.042 0.042 0.041 0.041 0.068 0.071 2428 2547 1663 466 828
24 60 0.056 0.056 0.056 0.056 0.098 0.105 3518 3782 2739 789 1422
22 60 0.070 0.070 0.070 0.070 0.129 0.132 4631 4744 3388 1169 2126
20 60 0.085 0.085 0.085 0.085 0.160 0.160 5749 5749 4101 1665 3047
CONSTRUCTION CLEAR SPANS

Composite Deck
Total Slab Concrete Maximum Construction Conc. Notes:
Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
26 4 - 0 4 - 9 4 - 10 1 - 3 2. Web crippling design strengths* and maximum construction
24 5 - 4 6 - 4 6 - 5 1 - 9 spans are based on 1 1/2'' for end bearing and 3'' for interior
2 1/2 24 0.167 bearing. Check web crippling if minimums are not met.
22 6 - 2 7 - 9 7 - 7 2 - 2
20 6 - 6 8 - 7 8 - 1 2 - 7 3. Maximum construction spans are based on ANSI/SDI
26 3 - 10 4 - 7 4 - 7 1 - 3 NC-2017 Standard for Non-Composite Steel Floor Deck
24 5 - 1 6 - 0 6 - 1 1 - 9 and the following construction loading:
3 30 0.209

Versa-Dek®
● Deck self-weight and concrete weight plus worst-case of
Normal-Weight Concrete (145 psf)

22 5 - 9 7 - 3 7 - 1 2 - 1

Long-Span Composite
20 6 - 1 8 - 2 7 - 6 2 - 6 either a 150 lb. concentrated load or a 20 psf
26 3 - 8 4 - 4 4 - 5 1 - 2 uniform load; or
24 4 - 10 5 - 8 5 - 9 1 - 8 ● Deck self-weight plus a 50 psf uniform
3 1/2 36 0.250
22 5 - 5 6 - 11 6 - 8 2 - 1 construction load, whichever controls.
20 5 - 9 7 - 9 7 - 1 2 - 5 4. Concrete weights do not include weight of deck.

Deep-Dek®
26 3 - 6 4 - 2 4 - 3 1 - 2 5. Deck profile has been accounted for in determining concrete
24 4 - 7 5 - 5 5 - 6 1 - 8 volumes. Deck and support deflections have not been
4 42 0.292
22 5 - 2 6 - 7 6 - 4 2 - 0 included in concrete volumes or weights.
20 5 - 6 7 - 4 6 - 9 2 - 4 6. Cantilever clear spans assume adjacent clear span is at least
26 3 - 5 4 - 0 4 - 1 1 - 2 3 times longer than the cantilever clear span and no greater
24 4 - 5 5 - 3 5 - 4 1 - 7 than spans shown. Bearing width at perimeter support
4 1/2 48 0.334
22 4 - 11 6 - 4 6 - 1 1 - 11 assumed to be 3'' minimum. Contact New Millennium
20 5 - 3 7 - 1 6 - 6 2 - 3 otherwise.

Form Deck
26 3 - 4 3 - 11 3 - 11 1 - 1
24 4 - 3 5 - 1 5 - 1 1 - 7
5 54 0.375
22 4 - 9 6 - 1 5 - 10 1 - 11
20 5 - 1 6 - 9 6 - 3 2 - 2
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
NWC (γc = 145 pcf, f'c = 3000 psi, n = 9, Fys = 60000 psi)

Depth, h (Mesh or 2 Clear Span (ft - in)


(in /ft)

Typical Fastener Layouts


(in) Deformed Bars) 3 - 0 4 - 0 4 - 6 5 - 0 5 - 6 6 - 0 6 - 6 7 - 0 8 - 0
6x6 - W2.9xW2.9 0.058 139 78 62 50 41 35 30 26 20
2 1/2 4x4 - W2.0xW2.0 0.060 144 81 64 52 43 36 31 26 20
6x6 - W4.0xW4.0 0.080 186 105 83 67 55 47 40 34 26
6x6 - W2.9xW2.9 0.058 189 106 84 68 56 47 40 35 27
3 4x4 - W2.0xW2.0 0.060 195 110 87 70 58 49 42 36 27
6x6 - W4.0xW4.0 0.080 255 143 113 92 76 64 54 47 36
6x6 - W4.0xW4.0 0.080 400 359 284 230 190 160 136 117 90
3 1/2 4x4 - W2.9xW2.9 0.087 400 392 310 251 207 174 148 128 98
4x4 - W4.0xW4.0 0.120 400 400 400 332 275 231 197 169 130
6x6 - W4.0xW4.0 0.080 400 400 345 279 231 194 165 142 109
4 4x4 - W2.9xW2.9 0.087 400 400 376 305 252 212 180 155 119
General Information
4x4 - W4.0xW4.0 0.120 400 400 400 400 341 287 244 211 161
4x4 - W2.9xW2.9 0.087 400 400 400 359 296 249 212 183 140
4 1/2 4x4 - W4.0xW4.0 0.120 400 400 400 400 400 338 288 249 190
#3 @ 9'' o.c. 0.147 400 400 400 400 400 400 343 296 226
4x4 - W4.0xW4.0 0.120 400 400 400 400 400 390 332 287 219
5 #3 @ 9'' o.c. 0.147 400 400 400 400 400 400 397 342 262
#4 @ 12'' o.c. 0.196 400 400 400 400 400 400 400 400 339
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive
Code of Standard Practice

steel rests on deck and negative steel cover = 3/4''.


● Galvanized deck. If non-galvanized deck or temporary shoring is used, the weight of the slab must be deducted from the uniform loads.
● End span of three span condion and ACI moment coefficients.
● Slab deflecon is limited to a minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 99
EHD-Dek
Table of Contents

LIGHTWEIGHT CONCRETE
Form Decks - Types EHD, EHDV
PROPERTIES 9
416 ˝ 3 3
Thickness Cover Weight 116 ˝ 116 ˝
Gage
(in) (in) (psf)
5
26 0.0179 0.98 116 ˝
24 0.0238 1.30
32 32˝ Coverage ICC-ES APPROVED
22 0.0295 1.61
0.0358 1.96
REFER TO ESR-1169
Roof Deck

20
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
26 60 0.073 0.073 0.072 0.072 0.095 0.104 3427 3724 1475 379 588
24 60 0.097 0.097 0.097 0.097 0.136 0.140 4874 5044 2607 650 1055
22 60 0.121 0.121 0.121 0.121 0.176 0.176 6305 6305 3621 971 1619
20 60 0.146 0.146 0.146 0.146 0.213 0.213 7650 7650 4385 1392 2367
CONSTRUCTION CLEAR SPANS
Composite Deck

Total Slab Concrete Maximum Construction Conc. Notes:


Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
26 5 - 5 6 - 5 6 - 6 1 - 9 2. Web crippling design strengths* and maximum construction
24 7 - 0 8 - 1 8 - 4 2 - 4 spans are based on 1 1/2'' for end bearing and 3'' for interior
3 21 0.195 bearing. Check web crippling if minimums are not met.
22 7 - 8 9 - 0 9 - 4 2 - 10
20 8 - 2 9 - 10 10 - 1 3 - 4 3. Maximum construction spans are based on ANSI/SDI
26 5 - 2 6 - 1 6 - 2 1 - 9 NC-2017 Standard for Non-Composite Steel Floor Deck
24 6 - 8 7 - 11 8 - 0 2 - 3 and the following construction loading:
3 1/2 26 0.237
Deep-Dek®

22 7 - 3 9 - 0 8 - 11 2 - 9 ● Deck self-weight and concrete weight plus worst-case of


Long-Span Composite

Lightweight Concrete (110 psf)

20 7 - 8 9 - 10 9 - 6 3 - 3 either a 150 lb. concentrated load or a 20 psf


26 4 - 11 5 - 10 5 - 11 1 - 8 uniform load; or
24 6 - 5 7 - 6 7 - 8 2 - 3 ● Deck self-weight plus a 50 psf uniform
4 31 0.278
22 6 - 10 8 - 11 8 - 6 2 - 8 construction load, whichever controls.
20 7 - 3 9 - 9 9 - 0 3 - 1 4. Concrete weights do not include weight of deck.
Versa-Dek®

26 4 - 9 5 - 8 5 - 9 1 - 8 5. Deck profile has been accounted for in determining concrete


24 6 - 1 7 - 3 7 - 4 2 - 2 volumes. Deck and support deflections have not been
4 1/2 35 0.320
22 6 - 7 8 - 7 8 - 1 2 - 7 included in concrete volumes or weights.
20 7 - 0 9 - 4 8 - 7 3 - 0 6. Cantilever clear spans assume adjacent clear span is at least
26 4 - 7 5 - 6 5 - 6 1 - 7 3 times longer than the cantilever clear span and no greater
24 5 - 10 7 - 0 7 - 1 2 - 1 than spans shown. Bearing width at perimeter support
5 40 0.362
22 6 - 4 8 - 3 7 - 9 2 - 6 assumed to be 3'' minimum. Contact New Millennium
20 6 - 8 9 - 0 8 - 3 2 - 11 otherwise.
Form Deck

26 4 - 6 5 - 3 5 - 4 1 - 7 7. Deck lengths over 40'-0'' require inquiry and special


24 5 - 8 6 - 9 6 - 10 2 - 1 accommodations. Please contact New Millennium for
5 1/2 44 0.403
22 6 - 1 7 - 11 7 - 6 2 - 6 further information.
20 6 - 6 8 - 8 8 - 0 2 - 10
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
LWC (γc = 110 pcf, f'c = 3000 psi, n = 14, Fys = 60000 psi)

Depth, h (Mesh or 2 Clear Span (ft - in)


(in /ft)
(in) Deformed Bars) 4 - 0 5 - 0 5 - 6 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 9 - 0
Typical Fastener Layouts

6x6 - W2.9xW2.9 0.058 88 56 47 39 33 29 25 22 17


3 4x4 - W2.0xW2.0 0.060 91 58 48 40 34 30 26 23 18
6x6 - W4.0xW4.0 0.080 118 76 63 53 45 39 34 30 23
6x6 - W4.0xW4.0 0.080 309 198 163 137 117 101 88 77 61
3 1/2 4x4 - W2.9xW2.9 0.087 337 216 178 150 128 110 96 84 67
4x4 - W4.0xW4.0 0.120 366 291 240 202 172 148 129 114 88
6x6 - W4.0xW4.0 0.080 386 247 204 172 146 126 110 97 76
4 4x4 - W2.9xW2.9 0.087 400 270 223 187 160 138 120 105 83
4x4 - W4.0xW4.0 0.120 400 365 302 253 216 186 162 143 113
4x4 - W2.9xW2.9 0.087 400 324 267 225 192 165 144 126 100
4 1/2 4x4 - W4.0xW4.0 0.120 400 400 363 305 260 224 195 172 136
General Information

#3 @ 9'' o.c. 0.147 400 400 400 361 308 266 231 203 161
4x4 - W4.0xW4.0 0.120 400 400 400 357 304 262 228 201 158
5 #3 @ 9'' o.c. 0.147 400 400 400 400 362 312 272 239 189
#4 @ 12'' o.c. 0.196 400 400 400 400 400 389 350 308 243
4x4 - W4.0xW4.0 0.120 400 400 400 400 348 300 261 230 181
5 1/2 #3 @ 9'' o.c. 0.147 400 400 400 400 400 358 312 274 217
#4 @ 12'' o.c. 0.196 400 400 400 400 400 400 400 355 281
Notes: 8. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive
Code of Standard Practice

steel rests on deck and negative steel cover = 3/4''.


● Galvanized deck. If non-galvanized deck or temporary shoring is used, the weight of the slab must be deducted from the uniform loads.
● End span of three span condion and ACI moment coefficients.
● Slab deflecon is limited to a minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
100 www.newmill.com/digital-tools
EHD-Dek

Table of Contents
NORMAL-WEIGHT CONCRETE
Form Decks - Types EHD, EHDV
9
PROPERTIES 416 ˝ 3 3
116 ˝ 116 ˝
Thickness Cover Weight
Gage
(in) (in) (psf) 5
26 0.0179 0.98 116 ˝
24 0.0238 1.30 ICC-ES APPROVED
32 32˝ Coverage
22 0.0295 1.61
REFER TO ESR-1169
0.0358 1.96

Roof Deck
20
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
26 60 0.073 0.073 0.072 0.072 0.095 0.104 3427 3724 1475 379 588
24 60 0.097 0.097 0.097 0.097 0.136 0.140 4874 5044 2607 650 1055
22 60 0.121 0.121 0.121 0.121 0.176 0.176 6305 6305 3621 971 1619
20 60 0.146 0.146 0.146 0.146 0.213 0.213 7650 7650 4385 1392 2367
CONSTRUCTION CLEAR SPANS

Composite Deck
Total Slab Concrete Maximum Construction Conc. Notes:
Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
26 5 - 1 6 - 0 6 - 1 1 - 9 2. Web crippling design strengths* and maximum construction
24 6 - 6 7 - 9 7 - 10 2 - 3 spans are based on 1 1/2'' for end bearing and 3'' for interior
3 28 0.195 bearing. Check web crippling if minimums are not met.
22 7 - 0 9 - 0 8 - 8 2 - 9
20 7 - 6 9 - 10 9 - 3 3 - 2 3. Maximum construction spans are based on ANSI/SDI
26 4 - 10 5 - 8 5 - 9 1 - 8 NC-2017 Standard for Non-Composite Steel Floor Deck
24 6 - 2 7 - 3 7 - 4 2 - 2 and the following construction loading:
3 1/2 34 0.237

Versa-Dek®
● Deck self-weight and concrete weight plus worst-case of
Normal-Weight Concrete (145 psf)

22 6 - 7 8 - 8 8 - 2 2 - 7

Long-Span Composite
20 7 - 0 9 - 5 8 - 8 3 - 1 either a 150 lb. concentrated load or a 20 psf
26 4 - 7 5 - 5 5 - 6 1 - 7 uniform load; or
24 5 - 10 6 - 11 7 - 0 2 - 1 ● Deck self-weight plus a 50 psf uniform
4 40 0.278
22 6 - 3 8 - 2 7 - 9 2 - 6 construction load, whichever controls.
20 6 - 8 8 - 11 8 - 3 2 - 11 4. Concrete weights do not include weight of deck.

Deep-Dek®
26 4 - 5 5 - 3 5 - 3 1 - 7 5. Deck profile has been accounted for in determining concrete
24 5 - 7 6 - 8 6 - 8 2 - 1 volumes. Deck and support deflections have not been
4 1/2 46 0.320
22 6 - 0 7 - 10 7 - 5 2 - 6 included in concrete volumes or weights.
20 6 - 5 8 - 7 7 - 11 2 - 10 6. Cantilever clear spans assume adjacent clear span is at least
26 4 - 3 5 - 0 5 - 1 1 - 7 3 times longer than the cantilever clear span and no greater
24 5 - 4 6 - 4 6 - 5 2 - 0 than spans shown. Bearing width at perimeter support
5 52 0.362
22 5 - 9 7 - 6 7 - 1 2 - 5 assumed to be 3'' minimum. Contact New Millennium
20 6 - 2 8 - 3 7 - 7 2 - 9 otherwise.

Form Deck
26 4 - 2 4 - 10 4 - 11 1 - 6 7. Deck lengths over 40'-0'' require inquiry and special
24 5 - 2 6 - 2 6 - 2 2 - 0 accommodations. Please contact New Millennium for
5 1/2 58 0.403
22 5 - 7 7 - 2 6 - 11 2 - 4 further information.
20 5 - 11 7 - 11 7 - 4 2 - 7
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
NWC (γc = 145 pcf, f'c = 3000 psi, n = 9, Fys = 60000 psi)

Depth, h (Mesh or 2 Clear Span (ft - in)


(in /ft)

Typical Fastener Layouts


(in) Deformed Bars) 4 - 0 5 - 0 5 - 6 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 9 - 0
6x6 - W2.9xW2.9 0.058 88 56 47 39 33 29 25 22 17
3 4x4 - W2.0xW2.0 0.060 91 58 48 40 34 30 26 23 18
6x6 - W4.0xW4.0 0.080 118 76 63 53 45 39 34 30 23
6x6 - W4.0xW4.0 0.080 309 198 163 137 117 101 88 77 61
3 1/2 4x4 - W2.9xW2.9 0.087 337 216 178 150 128 110 96 84 67
4x4 - W4.0xW4.0 0.120 400 291 240 202 172 148 129 114 90
6x6 - W4.0xW4.0 0.080 386 247 204 172 146 126 110 97 76
4 4x4 - W2.9xW2.9 0.087 400 270 223 187 160 138 120 105 83
4x4 - W4.0xW4.0 0.120 400 365 302 253 216 186 162 143 113
4x4 - W2.9xW2.9 0.087 400 324 267 225 192 165 144 126 100
4 1/2 4x4 - W4.0xW4.0 0.120 400 400 363 305 260 224 195 172 136
General Information
#3 @ 9'' o.c. 0.147 400 400 400 361 308 266 231 203 161
4x4 - W4.0xW4.0 0.120 400 400 400 357 304 262 228 201 158
5 #3 @ 9'' o.c. 0.147 400 400 400 400 362 312 272 239 189
#4 @ 12'' o.c. 0.196 400 400 400 400 400 400 350 308 243
4x4 - W4.0xW4.0 0.120 400 400 400 400 348 300 261 230 181
5 1/2 #3 @ 9'' o.c. 0.147 400 400 400 400 400 358 312 274 217
#4 @ 12'' o.c. 0.196 400 400 400 400 400 400 400 355 281
Notes: 8. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive
Code of Standard Practice

steel rests on deck and negative steel cover = 3/4''.


● Galvanized deck. If non-galvanized deck or temporary shoring is used, the weight of the slab must be deducted from the uniform loads.
● End span of three span condion and ACI moment coefficients.
● Slab deflecon is limited to a minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 101
1.5FD Form Deck
Table of Contents

LIGHTWEIGHT CONCRETE
Form Decks - Type 1.5FD
PROPERTIES
Thickness Cover Weight 6˝ 4 83 ˝
Gage 3 21 ˝
(in) (in) (psf)
22 0.0295 1.63 1 21 ˝
20 0.0358 1.98
36 ICC-ES
ICC-ESApproved
APPROVED-
18 0.0474 2.62 36˝ Coverage
REFERto
Refer TOESR-3818
ESR-3818
Roof Deck

16 0.0598 3.30
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.175 0.175 0.175 0.157 0.183 0.176 4391 4215 2009 654 1181
20 40 0.213 0.213 0.213 0.201 0.235 0.224 5624 5375 2428 932 1696
18 40 0.281 0.281 0.281 0.279 0.315 0.304 7553 7291 3192 1557 2858
16 40 0.355 0.355 0.355 0.355 0.395 0.390 9454 9332 3996 2381 4396
CONSTRUCTION CLEAR SPANS
Composite Deck

Total Slab Concrete Maximum Construction Conc. Notes:


Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
22 6 - 1 7 - 2 7 - 3 1 - 11 2. Web crippling design strengths* and maximum construction
20 7 - 3 8 - 3 8 - 7 2 - 4 spans are based on 1 1/2'' for end bearing and 3'' for interior
3 1/2 27 0.250 bearing. Check web crippling if minimums are not met.
18 8 - 10 9 - 7 9 - 11 3 - 1
16 10 - 0 10 - 9 11 - 2 3 - 8 3. Maximum construction spans are based on ANSI/SDI
22 5 - 10 6 - 11 7 - 0 1 - 11 NC-2017 Standard for Non-Composite Steel Floor Deck
20 6 - 11 8 - 1 8 - 3 2 - 4 and the following construction loading:
4 32 0.291
Deep-Dek®

● Deck self-weight and concrete weight plus worst-case of


Long-Span Composite

18 8 - 5 9 - 5 9 - 9 3 - 0
Lightweight Concrete (110 psf)

16 9 - 6 10 - 7 10 - 11 3 - 7 either a 150 lb. concentrated load or a 20 psf


22 5 - 7 6 - 8 6 - 8 1 - 10 uniform load; or
20 6 - 8 7 - 9 7 - 11 2 - 3 ● Deck self-weight plus a 50 psf uniform
4 1/2 37 0.333
18 8 - 1 9 - 0 9 - 4 2 - 11 construction load, whichever controls.
16 9 - 2 10 - 2 10 - 6 3 - 6 4. Concrete weights do not include weight of deck.
Versa-Dek®

22 5 - 5 6 - 5 6 - 6 1 - 10 5. Deck profile has been accounted for in determining concrete


20 6 - 5 7 - 6 7 - 8 2 - 3 volumes. Deck and support deflections have not been
5 41 0.375
18 7 - 9 8 - 8 9 - 0 2 - 10 included in concrete volumes or weights.
16 8 - 10 9 - 9 10 - 1 3 - 4 6. Cantilever clear spans assume adjacent clear span is at least
22 5 - 3 6 - 2 6 - 3 1 - 9 3 times longer than the cantilever clear span and no greater
20 6 - 3 7 - 3 7 - 4 2 - 2 than spans shown. Bearing width at perimeter support
5 1/2 46 0.416
18 7 - 6 8 - 5 8 - 8 2 - 9 assumed to be 3'' minimum. Contact New Millennium
16 8 - 6 9 - 5 9 - 9 3 - 3 otherwise.
Form Deck

22 5 - 1 6 - 0 6 - 1 1 - 9
20 6 - 0 7 - 0 7 - 2 2 - 2
6 50 0.458
18 7 - 3 8 - 1 8 - 5 2 - 8
16 8 - 3 9 - 2 9 - 6 3 - 2
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
LWC (γc = 110 pcf, f'c = 3000 psi, n = 14, Fys = 60000 psi)

Depth, h (Mesh or 2 Clear Span (ft - in)


(in /ft)
Typical Fastener Layouts

(in) Deformed Bars) 4 - 0 5 - 0 5 - 6 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 9 - 0


6x6 - W4.0xW4.0 0.080 214 137 113 95 81 70 61 53 42
3 1/2 4x4 - W2.9xW2.9 0.087 234 150 124 104 89 77 67 59 46
4x4 - W4.0xW4.0 0.120 284 182 150 126 108 93 81 71 56
6x6 - W4.0xW4.0 0.080 305 195 161 136 116 100 87 76 60
4 4x4 - W2.9xW2.9 0.087 325 208 172 145 123 106 93 81 64
4x4 - W4.0xW4.0 0.120 376 240 199 167 142 123 107 94 74
4x4 - W2.9xW2.9 0.087 400 283 234 196 167 144 126 110 87
4 1/2 4x4 - W4.0xW4.0 0.120 400 310 257 216 184 158 138 121 96
#3 @ 9'' o.c. 0.147 400 371 307 258 220 189 165 145 115
4x4 - W4.0xW4.0 0.120 400 400 336 282 241 208 181 159 126
5 #3 @ 9'' o.c. 0.147 400 400 392 330 281 242 211 186 147
General Information

#4 @ 12'' o.c. 0.196 400 400 400 376 320 276 241 212 167
4x4 - W4.0xW4.0 0.120 400 400 400 357 305 263 229 201 159
5 1/2 #3 @ 9'' o.c. 0.147 400 400 400 400 353 305 265 233 184
#4 @ 12'' o.c. 0.196 400 400 400 400 386 332 290 255 201
4x4 - W4.0xW4.0 0.120 400 400 400 400 375 324 282 248 196
6 #4 @ 18'' o.c. 0.131 400 400 400 400 400 345 301 264 209
#3 @ 9'' o.c. 0.147 400 400 400 400 400 373 325 286 226
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive
Code of Standard Practice

steel rests on deck and negative steel cover = 3/4''.


● Galvanized deck. If non-galvanized deck or temporary shoring is used, the weight of the slab must be deducted from the uniform loads.
● End span of three span condion and ACI moment coefficients.
● Slab deflecon is limited to a minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
102 www.newmill.com/digital-tools
1.5FD Form Deck

Table of Contents
Form Decks - Type 1.5FD NORMAL-WEIGHT CONCRETE

PROPERTIES 6˝
1 85 ˝ 2 21 ˝
Thickness Cover Weight 6˝ 4 83 ˝
Gage 3 21 ˝
(in) (in) (psf)
22 0.0295 1.63 1 21 ˝
20 0.0358 1.98
36 ICC-ESApproved
ICC-ES APPROVED-
18 0.0474 2.62 36˝
36˝ Coverage
Coverage REFERto
Refer TOESR-3818
ESR-3818

Roof Deck
16 0.0598 3.30
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.175 0.175 0.175 0.157 0.183 0.176 4391 4215 2009 654 1181
20 40 0.213 0.213 0.213 0.201 0.235 0.224 5624 5375 2428 932 1696
18 40 0.281 0.281 0.281 0.279 0.315 0.304 7553 7291 3192 1557 2858
16 40 0.355 0.355 0.355 0.355 0.395 0.390 9454 9332 3996 2381 4396
CONSTRUCTION CLEAR SPANS

Composite Deck
Total Slab Concrete Maximum Construction Conc. Notes:
Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
22 5 - 8 6 - 8 6 - 9 1 - 10 2. Web crippling design strengths* and maximum construction
20 6 - 8 7 - 10 7 - 11 2 - 3 spans are based on 1 1/2'' for end bearing and 3'' for interior
3 1/2 36 0.250 bearing. Check web crippling if minimums are not met.
18 8 - 1 9 - 1 9 - 4 2 - 11
16 9 - 2 10 - 2 10 - 7 3 - 6 3. Maximum construction spans are based on ANSI/SDI
22 5 - 5 6 - 4 6 - 5 1 - 10 NC-2017 Standard for Non-Composite Steel Floor Deck
20 6 - 5 7 - 5 7 - 7 2 - 2 and the following construction loading:
4 42 0.291

Versa-Dek®
● Deck self-weight and concrete weight plus worst-case of
Normal-Weight Concrete (145 psf)

Long-Span Composite
18 7 - 9 8 - 7 8 - 11 2 - 10
16 8 - 9 9 - 8 10 - 1 3 - 4 either a 150 lb. concentrated load or a 20 psf
22 5 - 2 6 - 1 6 - 2 1 - 9 uniform load; or
20 6 - 1 7 - 1 7 - 3 2 - 2 ● Deck self-weight plus a 50 psf uniform
4 1/2 48 0.333
18 7 - 5 8 - 3 8 - 6 2 - 9 construction load, whichever controls.
16 8 - 5 9 - 3 9 - 7 3 - 2 4. Concrete weights do not include weight of deck.

Deep-Dek®
22 5 - 0 5 - 10 5 - 11 1 - 9 5. Deck profile has been accounted for in determining concrete
20 5 - 11 6 - 10 6 - 11 2 - 1 volumes. Deck and support deflections have not been
5 54 0.375
18 7 - 1 7 - 11 8 - 2 2 - 8 included in concrete volumes or weights.
16 8 - 1 8 - 11 9 - 3 3 - 1 6. Cantilever clear spans assume adjacent clear span is at least
22 4 - 10 5 - 8 5 - 9 1 - 8 3 times longer than the cantilever clear span and no greater
20 5 - 8 6 - 7 6 - 8 2 - 1 than spans shown. Bearing width at perimeter support
5 1/2 60 0.416
18 6 - 10 7 - 7 7 - 11 2 - 7 assumed to be 3'' minimum. Contact New Millennium
16 7 - 10 8 - 7 8 - 11 2 - 11 otherwise.

Form Deck
22 4 - 8 5 - 6 5 - 6 1 - 8
20 5 - 6 6 - 4 6 - 6 2 - 0
6 66 0.458
18 6 - 7 7 - 4 7 - 7 2 - 6
16 7 - 7 8 - 3 8 - 7 2 - 10
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
NWC (γc = 145 pcf, f'c = 3000 psi, n = 9, Fys = 60000 psi)

Depth, h (Mesh or 2 Clear Span (ft - in)


(in /ft)

Typical Fastener Layouts


(in) Deformed Bars) 4 - 0 5 - 0 5 - 6 6 - 0 6 - 6 7 - 0 7 - 6 8 - 0 9 - 0
6x6 - W4.0xW4.0 0.080 214 137 113 95 81 70 61 53 42
3 1/2 4x4 - W2.9xW2.9 0.087 234 150 124 104 89 77 67 59 46
4x4 - W4.0xW4.0 0.120 284 182 150 126 108 93 81 71 56
6x6 - W4.0xW4.0 0.080 305 195 161 136 116 100 87 76 60
4 4x4 - W2.9xW2.9 0.087 325 208 172 145 123 106 93 81 64
4x4 - W4.0xW4.0 0.120 376 240 199 167 142 123 107 94 74
4x4 - W2.9xW2.9 0.087 400 283 234 196 167 144 126 110 87
4 1/2 4x4 - W4.0xW4.0 0.120 400 310 257 216 184 158 138 121 96
#3 @ 9'' o.c. 0.147 400 371 307 258 220 189 165 145 115
4x4 - W4.0xW4.0 0.120 400 400 336 282 241 208 181 159 126
5 #3 @ 9'' o.c. 0.147 400 400 392 330 281 242 211 186 147
General Information
#4 @ 12'' o.c. 0.196 400 400 400 376 320 276 241 212 167
4x4 - W4.0xW4.0 0.120 400 400 400 357 305 263 229 201 159
5 1/2 #3 @ 9'' o.c. 0.147 400 400 400 400 353 305 265 233 184
#4 @ 12'' o.c. 0.196 400 400 400 400 386 332 290 255 201
4x4 - W4.0xW4.0 0.120 400 400 400 400 375 324 282 248 196
6 #4 @ 18'' o.c. 0.131 400 400 400 400 400 345 301 264 209
#3 @ 9'' o.c. 0.147 400 400 400 400 400 373 325 286 226
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive
Code of Standard Practice

steel rests on deck and negative steel cover = 3/4''.


● Galvanized deck. If non-galvanized deck or temporary shoring is used, the weight of the slab must be deducted from the uniform loads.
● End span of three span condion and ACI moment coefficients.
● Slab deflecon is limited to a minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 103
1.5FDR, 1.5FDI, 1.5FDV, 1.5FDIV Form Deck
Table of Contents

Form Decks - Types 1.5FDR, 1.5FDI, 1.5FDV, 1.5FDIV


LIGHTWEIGHT CONCRETE

PROPERTIES 6˝
1 85 ˝ 2 21 ˝
Thickness Cover Weight
Gage
(in) (in) (psf)
22 0.0295 1.63 1 21 ˝
20 0.0358 1.98
36 ICC-ESApproved
ICC-ES APPROVED-
18 0.0474 2.62 36˝ Coverage
0.0598 3.30 REFERto
Refer TOESR-3818
ESR-3818
Roof Deck

16
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.163 0.175 0.157 0.175 0.176 0.183 4215 4391 2009 654 1181
20 40 0.205 0.213 0.201 0.213 0.224 0.235 5375 5624 2428 932 1696
18 40 0.280 0.281 0.279 0.281 0.304 0.315 7291 7553 3192 1557 2858
16 40 0.355 0.355 0.355 0.355 0.390 0.395 9332 9454 3996 2381 4396
CONSTRUCTION CLEAR SPANS
Composite Deck

Total Slab Concrete Maximum Construction Conc. Notes:


Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
22 6 - 2 7 - 3 7 - 4 2 - 0 2. Web crippling design strengths* and maximum construction
20 7 - 4 8 - 5 8 - 9 2 - 6 spans are based on 1 1/2'' for end bearing and 3'' for interior
3 1/2 23 0.213 bearing. Check web crippling if minimums are not met.
18 9 - 0 9 - 9 10 - 1 3 - 3
16 10 - 6 10 - 10 11 - 3 3 - 9 3. Maximum construction spans are based on ANSI/SDI
22 5 - 10 6 - 11 7 - 0 2 - 0 NC-2017 Standard for Non-Composite Steel Floor Deck
20 7 - 0 8 - 3 8 - 4 2 - 5 and the following construction loading:
4 28 0.255
Deep-Dek®

18 8 - 7 9 - 9 10 - 1 3 - 2 ● Deck self-weight and concrete weight plus worst-case of


Long-Span Composite

Lightweight Concrete (110 psf)

16 9 - 11 10 - 10 11 - 3 3 - 9 either a 150 lb. concentrated load or a 20 psf


22 5 - 8 6 - 8 6 - 9 1 - 11 uniform load; or
20 6 - 8 7 - 10 7 - 11 2 - 5 ● Deck self-weight plus a 50 psf uniform
4 1/2 33 0.297
18 8 - 2 9 - 6 9 - 9 3 - 0 construction load, whichever controls.
16 9 - 6 10 - 7 10 - 11 3 - 7 4. Concrete weights do not include weight of deck.
Versa-Dek®

22 5 - 5 6 - 5 6 - 6 1 - 11 5. Deck profile has been accounted for in determining concrete


20 6 - 5 7 - 7 7 - 8 2 - 4 volumes. Deck and support deflections have not been
5 37 0.338
18 7 - 10 9 - 2 9 - 4 3 - 0 included in concrete volumes or weights.
16 9 - 1 10 - 2 10 - 6 3 - 6 6. Cantilever clear spans assume adjacent clear span is at least
22 5 - 3 6 - 2 6 - 3 1 - 10 3 times longer than the cantilever clear span and no greater
20 6 - 2 7 - 3 7 - 4 2 - 3 than spans shown. Bearing width at perimeter support
5 1/2 42 0.380
18 7 - 7 8 - 10 8 - 11 2 - 11 assumed to be 3'' minimum. Contact New Millennium
16 8 - 9 9 - 10 10 - 2 3 - 4 otherwise.
Form Deck

22 5 - 1 6 - 0 6 - 1 1 - 10
20 6 - 0 7 - 0 7 - 1 2 - 3
6 46 0.422
18 7 - 4 8 - 6 8 - 8 2 - 10
16 8 - 6 9 - 6 9 - 10 3 - 3
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
LWC (γc = 110 pcf, f'c = 3000 psi, n = 14, Fys = 60000 psi)

Depth, h (Mesh or 2 Clear Span (ft - in)


(in /ft)
(in) Deformed Bars) 4 - 0 5 - 0 5 - 6 6 - 0 6 - 6 7 - 0 8 - 0 9 - 0 10 - 0
Typical Fastener Layouts

6x6 - W2.9xW2.9 0.058 161 103 85 72 61 53 40 32 26


3 1/2 4x4 - W2.0xW2.0 0.060 170 109 90 76 64 56 42 34 27
6x6 - W4.0xW4.0 0.080 197 126 104 87 74 64 49 39 31
6x6 - W4.0xW4.0 0.080 257 165 136 114 97 84 64 51 41
4 4x4 - W2.9xW2.9 0.087 281 180 149 125 106 92 70 56 45
4x4 - W4.0xW4.0 0.120 283 221 183 154 131 113 86 68 55
6x6 - W4.0xW4.0 0.080 352 226 187 157 134 115 88 70 56
4 1/2 4x4 - W2.9xW2.9 0.087 359 241 199 167 143 123 94 74 60
4x4 - W4.0xW4.0 0.120 352 280 231 194 166 143 109 86 70
4x4 - W4.0xW4.0 0.120 400 342 291 245 209 180 138 109 88
5 #3 @ 9'' o.c. 0.147 400 361 328 290 247 213 163 129 105
General Information

#4 @ 12'' o.c. 0.196 400 353 321 294 271 252 197 156 126
4x4 - W4.0xW4.0 0.120 400 400 369 311 265 229 175 138 112
5 1/2 #3 @ 9'' o.c. 0.147 400 400 388 356 310 267 205 162 131
#4 @ 12'' o.c. 0.196 400 400 380 349 322 299 235 185 150
4x4 - W4.0xW4.0 0.120 400 400 400 385 328 283 216 171 138
6 #4 @ 18'' o.c. 0.131 400 400 400 400 353 304 233 184 149
#3 @ 9'' o.c. 0.147 400 400 400 400 381 329 252 199 161
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive
Code of Standard Practice

steel rests on deck and negative steel cover = 3/4''.


● Galvanized deck. If non-galvanized deck or temporary shoring is used, the weight of the slab must be deducted from the uniform loads.
● End span of three span condion and ACI moment coefficients.
● Slab deflecon is limited to a minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
104 www.newmill.com/digital-tools
1.5FDR, 1.5FDI, 1.5FDV, 1.5FDIV Form Deck

Table of Contents
Form Decks - Types 1.5FDR, 1.5FDI, 1.5FDV, 1.5FDIV
NORMAL-WEIGHT CONCRETE

PROPERTIES 6˝
1 85 ˝ 2 21 ˝
Thickness Cover Weight
Gage
(in) (in) (psf)
22 0.0295 1.63 1 21 ˝
20 0.0358 1.98
36 ICC-ES Approved
ICC-ES APPROVED -
18 0.0474 2.62 36˝ Coverage
REFERto
Refer TOESR-3818
ESR-3818

Roof Deck
16 0.0598 3.30
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.163 0.175 0.157 0.175 0.176 0.183 4215 4391 2009 654 1181
20 40 0.205 0.213 0.201 0.213 0.224 0.235 5375 5624 2428 932 1696
18 40 0.280 0.281 0.279 0.281 0.304 0.315 7291 7553 3192 1557 2858
16 40 0.355 0.355 0.355 0.355 0.390 0.395 9332 9454 3996 2381 4396
CONSTRUCTION CLEAR SPANS

Composite Deck
Total Slab Concrete Maximum Construction Conc. Notes:
Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
22 5 - 9 6 - 9 6 - 10 2 - 0 2. Web crippling design strengths* and maximum construction
20 6 - 9 8 - 0 8 - 1 2 - 5 spans are based on 1 1/2'' for end bearing and 3'' for interior
3 1/2 31 0.213 bearing. Check web crippling if minimums are not met.
18 8 - 4 9 - 8 9 - 11 3 - 1
16 9 - 8 10 - 9 11 - 1 3 - 8 3. Maximum construction spans are based on ANSI/SDI
22 5 - 5 6 - 5 6 - 6 1 - 11 NC-2017 Standard for Non-Composite Steel Floor Deck
20 6 - 5 7 - 7 7 - 8 2 - 4 and the following construction loading:
4 37 0.255

Versa-Dek®
● Deck self-weight and concrete weight plus worst-case of
Normal-Weight Concrete (145 psf)

Long-Span Composite
18 7 - 11 9 - 2 9 - 4 3 - 0
16 9 - 1 10 - 2 10 - 6 3 - 6 either a 150 lb. concentrated load or a 20 psf
22 5 - 3 6 - 2 6 - 3 1 - 10 uniform load; or
20 6 - 2 7 - 3 7 - 4 2 - 3 ● Deck self-weight plus a 50 psf uniform
4 1/2 43 0.297
18 7 - 6 8 - 9 8 - 10 2 - 10 construction load, whichever controls.
16 8 - 8 9 - 8 10 - 1 3 - 4 4. Concrete weights do not include weight of deck.

Deep-Dek®
22 5 - 0 5 - 11 5 - 11 1 - 10 5. Deck profile has been accounted for in determining concrete
20 5 - 11 6 - 11 7 - 0 2 - 3 volumes. Deck and support deflections have not been
5 49 0.338
18 7 - 2 8 - 4 8 - 6 2 - 9 included in concrete volumes or weights.
16 8 - 4 9 - 3 9 - 7 3 - 2 6. Cantilever clear spans assume adjacent clear span is at least
22 4 - 10 5 - 8 5 - 9 1 - 9 3 times longer than the cantilever clear span and no greater
20 5 - 8 6 - 8 6 - 9 2 - 2 than spans shown. Bearing width at perimeter support
5 1/2 55 0.380
18 6 - 11 8 - 0 8 - 2 2 - 8 assumed to be 3'' minimum. Contact New Millennium
16 8 - 0 8 - 11 9 - 3 3 - 1 otherwise.

Form Deck
22 4 - 8 5 - 6 5 - 7 1 - 9
20 5 - 6 6 - 5 6 - 6 2 - 1
6 61 0.422
18 6 - 8 7 - 9 7 - 10 2 - 7
16 7 - 9 8 - 7 8 - 11 2 - 11
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
NWC (γc = 145 pcf, f'c = 3000 psi, n = 9, Fys = 60000 psi)

Depth, h (Mesh or 2 Clear Span (ft - in)


(in /ft)

Typical Fastener Layouts


(in) Deformed Bars) 4 - 0 5 - 0 5 - 6 6 - 0 6 - 6 7 - 0 8 - 0 9 - 0 10 - 0
6x6 - W2.9xW2.9 0.058 161 103 85 72 61 53 40 32 26
3 1/2 4x4 - W2.0xW2.0 0.060 170 109 90 76 64 56 42 34 27
6x6 - W4.0xW4.0 0.080 197 126 104 87 74 64 49 39 31
6x6 - W4.0xW4.0 0.080 257 165 136 114 97 84 64 51 41
4 4x4 - W2.9xW2.9 0.087 281 180 149 125 106 92 70 56 45
4x4 - W4.0xW4.0 0.120 333 221 183 154 131 113 86 68 55
6x6 - W4.0xW4.0 0.080 353 226 187 157 134 115 88 70 56
4 1/2 4x4 - W2.9xW2.9 0.087 377 241 199 167 143 123 94 74 60
4x4 - W4.0xW4.0 0.120 400 280 231 194 166 143 109 86 70
4x4 - W4.0xW4.0 0.120 400 353 291 245 209 180 138 109 88
5 #3 @ 9'' o.c. 0.147 400 400 346 290 247 213 163 129 105
General Information
#4 @ 12'' o.c. 0.196 400 400 377 346 299 258 197 156 126
4x4 - W4.0xW4.0 0.120 400 400 370 311 265 229 175 138 112
5 1/2 #3 @ 9'' o.c. 0.147 400 400 400 364 310 267 205 162 131
#4 @ 12'' o.c. 0.196 400 400 400 400 356 307 235 185 150
4x4 - W4.0xW4.0 0.120 400 400 400 385 328 283 216 171 138
6 #4 @ 18'' o.c. 0.131 400 400 400 400 353 304 233 184 149
#3 @ 9'' o.c. 0.147 400 400 400 400 381 329 252 199 161
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive
Code of Standard Practice

steel rests on deck and negative steel cover = 3/4''.


● Galvanized deck. If non-galvanized deck or temporary shoring is used, the weight of the slab must be deducted from the uniform loads.
● End span of three span condion and ACI moment coefficients.
● Slab deflecon is limited to a minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 105
2.0FD Form Deck
Table of Contents

LIGHTWEIGHT CONCRETE
Form Decks - Type 2.0FD
PROPERTIES Optional run-out side lap for screws
Thickness Cover Weight 7˝
Gage 12˝
(in) (in) (psf) 5˝
22 0.0295 1.57 2˝
20 0.0358 1.90
36 ICC-ES APPROVED
18 0.0474 2.52 36˝ Coverage REFER TO ESR-3818
Roof Deck

16 0.0598 3.17
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.341 0.341 0.337 0.328 0.257 0.261 6153 6263 1474 321 617
20 40 0.419 0.419 0.418 0.410 0.342 0.346 8189 8285 1963 459 882
18 40 0.555 0.555 0.554 0.554 0.506 0.510 12108 12205 2590 769 1477
16 40 0.701 0.701 0.699 0.700 0.650 0.651 15572 15583 3255 1176 2260
CONSTRUCTION CLEAR SPANS
Composite Deck

Total Slab Concrete Maximum Construction Conc. Notes:


Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
2. Web crippling design strengths* and maximum construction
22 7 - 9 8 - 11 9 - 3 2 - 8
spans are based on 2'' for end bearing and 4'' for interior
20 9 - 5 10 - 3 10 - 7 3 - 5
4 27 0.248 bearing. Check web crippling if minimums are not met.
18 11 - 7 12 - 5 12 - 10 4 - 3 3. Maximum construction spans are based on ANSI/SDI
16 12 - 3 13 - 11 14 - 4 4 - 9 NC-2017 Standard for Non-Composite Steel Floor Deck
22 7 - 5 8 - 9 8 - 10 2 - 7 and the following construction loading:
20 9 - 0 10 - 1 10 - 5 3 - 4 ● Deck self-weight and concrete weight plus worst-case of
Deep-Dek®

4 1/2 32 0.289
Long-Span Composite

18 11 - 2 12 - 2 12 - 7 4 - 2 either a 150 lb. concentrated load or a 20 psf


Lightweight Concrete (110 pcf)

16 11 - 10 13 - 8 13 - 10 4 - 7 uniform load; or
22 7 - 2 8 - 4 8 - 6 2 - 7 ● Deck self-weight plus a 50 psf uniform
20 8 - 7 9 - 8 10 - 0 3 - 3 construction load, whichever controls.
5 36 0.331
18 10 - 9 11 - 8 12 - 1 4 - 0 4. Concrete weights do not include weight of deck.
Versa-Dek®

16 11 - 5 13 - 2 13 - 5 4 - 5 5. Deck profile has been accounted for in determining concrete


22 6 - 10 7 - 10 8 - 2 2 - 6 volumes. Deck and support deflections have not been
20 8 - 3 9 - 3 9 - 7 3 - 1 included in concrete volumes or weights.
5 1/2 41 0.373 6. Cantilever clear spans assume adjacent clear span is at least
18 10 - 4 11 - 3 11 - 8 3 - 10
3 times longer than the cantilever clear span and no greater
16 11 - 1 12 - 8 13 - 1 4 - 4
than spans shown. Bearing width at perimeter support
22 6 - 8 7 - 4 7 - 10 2 - 5
assumed to be 4'' minimum. Contact New Millennium otherwise.
20 8 - 0 9 - 0 9 - 3 3 - 0
6 46 0.414
18 10 - 0 10 - 10 11 - 3 3 - 9
Form Deck

16 10 - 9 12 - 3 12 - 8 4 - 2
22 6 - 5 6 - 10 7 - 7 2 - 5
20 7 - 9 8 - 8 8 - 11 2 - 11
6 1/2 50 0.456
18 9 - 8 10 - 6 10 - 10 3 - 7
16 10 - 5 11 - 10 12 - 3 4 - 1
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
LWC (γc = 110 pcf, f'c = 3000 psi, n = 14, Fys = 60000 psi)

Depth, h (Mesh or 2 Clear Span (ft - in)


Typical Fastener Layouts

(in /ft)
(in) Deformed Bars) 6 - 0 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0
6x6 - W4.0xW4.0 0.080 120 88 77 68 60 53 43 36 30
4 4x4 - W2.9xW2.9 0.087 131 97 84 74 66 58 47 39 33
4x4 - W4.0xW4.0 0.120 174 128 111 98 87 77 63 43 36
6x6 - W4.0xW4.0 0.080 155 114 99 87 77 69 56 46 39
4 1/2 4x4 - W2.9xW2.9 0.087 169 124 108 95 84 75 61 50 42
4x4 - W4.0xW4.0 0.120 228 167 146 128 114 101 82 59 50
4x4 - W2.9xW2.9 0.087 206 152 132 116 103 92 74 61 52
5 4x4 - W4.0xW4.0 0.120 279 205 179 157 139 124 101 77 65
#3 @ 9'' o.c. 0.147 330 242 211 186 164 147 119 88 74
4x4 - W4.0xW4.0 0.120 331 243 212 186 165 147 119 97 82
5 1/2 #3 @ 9'' o.c. 0.147 393 289 252 221 196 175 142 111 93
General Information

#4 @ 12'' o.c. 0.196 400 351 305 268 238 212 172 118 99
4x4 - W4.0xW4.0 0.120 383 281 245 215 191 170 138 114 96
6 #4 @ 18'' o.c. 0.131 400 294 256 225 200 178 144 119 100
#3 @ 9'' o.c. 0.147 400 335 292 257 228 203 164 136 114
4x4 - W4.0xW4.0 0.120 400 319 278 244 216 193 156 129 109
6 1/2 #4 @ 18'' o.c. 0.131 400 336 292 257 228 203 164 136 114
#3 @ 9'' o.c. 0.147 400 382 333 292 259 231 187 155 130
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive steel
Code of Standard Practice

rests on deck and negative steel cover = 3/4''.


● Galvanized deck. If non-galvanized deck or temporary shoring is used, the weight of the slab must be deducted from the uniform loads.
● End span of three span condion and ACI moment coefficients.
● Slab deflecon is limited to a minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
106 www.newmill.com/digital-tools
2.0FD Form Deck

Table of Contents
Form Decks - Type 2.0FD NORMAL-WEIGHT CONCRETE

PROPERTIES Optional run-out side lap for screws


Thickness Cover Weight 7˝
Gage 12˝
(in) (in) (psf) 5˝
22 0.0295 1.57 2˝
20 0.0358 1.90
36 ICC-ES APPROVED
18 0.0474 2.52 36˝ Coverage REFER TO ESR-3818

Roof Deck
16 0.0598 3.17
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.341 0.341 0.337 0.328 0.257 0.261 6153 6263 1474 321 617
20 40 0.419 0.419 0.418 0.410 0.342 0.346 8189 8285 1963 459 882
18 40 0.555 0.555 0.554 0.554 0.506 0.510 12108 12205 2590 769 1477
16 40 0.701 0.701 0.699 0.700 0.650 0.651 15572 15583 3255 1176 2260
CONSTRUCTION CLEAR SPANS

Composite Deck
Total Slab Concrete Maximum Construction Conc. Notes:
Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
2. Web crippling design strengths* and maximum construction
22 7 - 2 8 - 5 8 - 6 2 - 7
spans are based on 2'' for end bearing and 4'' for interior
20 8 - 8 9 - 8 10 - 0 3 - 3
4 36 0.248 bearing. Check web crippling if minimums are not met.
18 10 - 9 11 - 9 12 - 2 4 - 0 3. Maximum construction spans are based on ANSI/SDI
16 11 - 6 13 - 2 13 - 6 4 - 6 NC-2017 Standard for Non-Composite Steel Floor Deck
22 6 - 10 7 - 9 8 - 1 2 - 6 and the following construction loading:
20 8 - 3 9 - 3 9 - 7 3 - 1 ● Deck self-weight and concrete weight plus worst-case of

Versa-Dek®
4 1/2 42 0.289

Long-Span Composite
18 10 - 3 11 - 2 11 - 7 3 - 10
Normal Weight Concrete (145 pcf)

either a 150 lb. concentrated load or a 20 psf


16 11 - 0 12 - 7 13 - 0 4 - 4 uniform load; or
22 6 - 6 7 - 1 7 - 9 2 - 5 ● Deck self-weight plus a 50 psf uniform
20 7 - 10 8 - 9 9 - 1 3 - 0 construction load, whichever controls.
5 48 0.331
18 9 - 10 10 - 8 11 - 0 3 - 8 4. Concrete weights do not include weight of deck.
5. Deck profile has been accounted for in determining concrete

Deep-Dek®
16 10 - 7 12 - 0 12 - 5 4 - 1
22 6 - 1 6 - 6 7 - 4 2 - 4 volumes. Deck and support deflections have not been
20 7 - 6 8 - 5 8 - 9 2 - 11 included in concrete volumes or weights.
5 1/2 54 0.373 6. Cantilever clear spans assume adjacent clear span is at least
18 9 - 6 10 - 3 10 - 7 3 - 6
3 times longer than the cantilever clear span and no greater
16 10 - 2 11 - 6 11 - 11 3 - 11
than spans shown. Bearing width at perimeter support
22 5 - 6 6 - 0 6 - 10 2 - 3
assumed to be 4'' minimum. Contact New Millennium otherwise.
20 7 - 3 8 - 1 8 - 5 2 - 9
6 60 0.414
18 9 - 2 9 - 10 10 - 2 3 - 4
16 9 - 10 11 - 1 11 - 6 3 - 10

Form Deck
22 5 - 0 5 - 6 6 - 3 2 - 1
20 7 - 0 7 - 10 8 - 1 2 - 8
6 1/2 66 0.456
18 8 - 10 9 - 6 9 - 10 3 - 3
16 9 - 7 10 - 8 11 - 1 3 - 8
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
NWC (γc = 145 pcf, f'c = 3000 psi, n = 9, Fys = 60000 psi)

Depth, h (Mesh or 2 Clear Span (ft - in)

Typical Fastener Layouts


(in /ft)
(in) Deformed Bars) 6 - 0 7 - 0 7 - 6 8 - 0 8 - 6 9 - 0 10 - 0 11 - 0 12 - 0
6x6 - W4.0xW4.0 0.080 120 88 77 68 60 53 43 36 30
4 4x4 - W2.9xW2.9 0.087 131 97 84 74 66 58 47 39 33
4x4 - W4.0xW4.0 0.120 174 128 111 98 87 77 63 43 36
6x6 - W4.0xW4.0 0.080 155 114 99 87 77 69 56 46 39
4 1/2 4x4 - W2.9xW2.9 0.087 169 124 108 95 84 75 61 50 42
4x4 - W4.0xW4.0 0.120 228 167 146 128 114 101 82 59 50
4x4 - W2.9xW2.9 0.087 206 152 132 116 103 92 74 61 52
5 4x4 - W4.0xW4.0 0.120 279 205 179 157 139 124 101 77 65
#3 @ 9'' o.c. 0.147 330 242 211 186 164 147 119 88 74
4x4 - W4.0xW4.0 0.120 331 243 212 186 165 147 119 97 82
5 1/2 #3 @ 9'' o.c. 0.147 393 289 252 221 196 175 142 111 93
General Information

#4 @ 12'' o.c. 0.196 400 351 305 268 238 212 172 118 99
4x4 - W4.0xW4.0 0.120 383 281 245 215 191 170 138 114 96
6 #4 @ 18'' o.c. 0.131 400 294 256 225 200 178 144 119 100
#3 @ 9'' o.c. 0.147 400 335 292 257 228 203 164 136 114
4x4 - W4.0xW4.0 0.120 400 319 278 244 216 193 156 129 109
6 1/2 #4 @ 18'' o.c. 0.131 400 336 292 257 228 203 164 136 114
#3 @ 9'' o.c. 0.147 400 382 333 292 259 231 187 155 130
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive steel
Code of Standard Practice

rests on deck and negative steel cover = 3/4''.


● Galvanized deck. If non-galvanized deck or temporary shoring is used, the weight of the slab must be deducted from the uniform loads.
● End span of three span condion and ACI moment coefficients.
● Slab deflecon is limited to a minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 107
3.0FD Form Deck
Table of Contents

LIGHTWEIGHT CONCRETE
Form Decks - Type 3.0FD
PROPERTIES Optional run-out side lap for screws
Thickness Cover Weight 7 41 ˝ 12˝
Gage
(in) (in) (psf)
4 43 ˝
22 0.0295 1.71 3˝
20 0.0358 2.07
36 ICC-ES APPROVED
18 0.0474 2.74
36˝ Coverage REFER TO ESR-3818
Roof Deck

16 0.0598 3.45
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage 4 4 4 4 3 3
(ksi) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in /ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.770 0.770 0.764 0.750 0.407 0.424 9749 10151 1416 336 677
20 40 0.946 0.946 0.945 0.934 0.537 0.556 12871 13319 2227 482 967
18 40 1.253 1.253 1.252 1.253 0.794 0.802 19016 19213 3895 811 1615
16 40 1.580 1.580 1.579 1.579 1.012 1.013 24245 24264 4901 1245 2466
CONSTRUCTION CLEAR SPANS
Composite Deck

Total Slab Concrete Maximum Construction Conc. Notes:


Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
2. Web crippling design strengths* and maximum construction
22 10 - 1 10 - 0 11 - 5 3 - 9
spans are based on 2 1/2'' for end bearing and 5'' for interior
20 12 - 0 12 - 8 13 - 2 4 - 4
5 32 0.292 bearing. Check web crippling if minimums are not met.
18 13 - 8 15 - 3 15 - 9 5 - 3 3. Maximum construction spans are based on ANSI/SDI
16 14 - 5 17 - 0 16 - 11 5 - 8 NC-2017 Standard for Non-Composite Steel Floor Deck
22 9 - 8 9 - 3 10 - 6 3 - 6 and the following construction loading:
20 11 - 6 12 - 2 12 - 7 4 - 2
Deep-Dek®

5 1/2 37 0.333 ● Deck self-weight and concrete weight plus worst-case of


Long-Span Composite

18 13 - 3 14 - 8 15 - 2 5 - 0 either a 150 lb. concentrated load or a 20 psf


Lightweight Concrete (110 pcf)

16 14 - 0 16 - 4 16 - 5 5 - 5 uniform load; or
22 8 - 7 8 - 7 9 - 9 3 - 3 ● Deck self-weight plus a 50 psf uniform
20 11 - 0 11 - 9 12 - 2 4 - 0 construction load, whichever controls.
6 41 0.375
18 12 - 11 14 - 1 14 - 7 4 - 10 4. Concrete weights do not include weight of deck.
Versa-Dek®

16 13 - 7 15 - 9 16 - 0 5 - 4 5. Deck profile has been accounted for in determining concrete


22 7 - 9 8 - 0 9 - 1 3 - 0 volumes. Deck and support deflections have not been
20 10 - 7 11 - 4 11 - 8 3 - 10 included in concrete volumes or weights.
6 1/2 46 0.417 6. Cantilever clear spans assume adjacent clear span is at least
18 12 - 7 13 - 7 14 - 1 4 - 8
3 times longer than the cantilever clear span and no greater
16 13 - 3 15 - 3 15 - 7 5 - 2
than spans shown. Bearing width at perimeter support
22 7 - 1 7 - 6 8 - 6 2 - 10
assumed to be 5'' minimum. Contact New Millennium otherwise.
20 10 - 2 10 - 8 11 - 4 3 - 9
7 50 0.458
18 12 - 4 13 - 2 13 - 8 4 - 6
Form Deck

16 13 - 0 14 - 9 15 - 3 5 - 1
22 6 - 6 7 - 0 8 - 0 2 - 8
20 9 - 10 10 - 0 11 - 0 3 - 8
7 1/2 55 0.500
18 12 - 1 12 - 9 13 - 2 4 - 4
16 12 - 9 14 - 4 14 - 10 4 - 11
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
LWC (γc = 110 pcf, f'c = 3000 psi, n = 14, Fys = 60000 psi)

Depth, h (Mesh or Clear Span (ft - in)


Typical Fastener Layouts

2
(in /ft)
(in) Deformed Bars) 7 - 0 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0
6x6 - W4.0xW4.0 0.080 91 70 55 45 37 31 26 23 20
5 4x4 - W2.9xW2.9 0.087 100 76 60 49 40 34 29 25 22
4x4 - W4.0xW4.0 0.120 134 103 81 66 54 46 39 34 29
4x4 - W2.9xW2.9 0.087 127 98 77 62 52 43 37 32 28
5 1/2 4x4 - W4.0xW4.0 0.120 172 132 104 84 70 59 50 43 37
#3 @ 9'' o.c. 0.147 202 154 122 99 82 69 58 50 44
4x4 - W4.0xW4.0 0.120 210 161 127 103 85 71 61 52 46
6 #4 @ 18'' o.c. 0.131 217 166 131 106 88 74 63 54 47
#3 @ 9'' o.c. 0.147 248 190 150 122 100 84 72 62 54
4x4 - W4.0xW4.0 0.120 248 190 150 121 100 84 72 62 54
6 1/2 #4 @ 18'' o.c. 0.131 258 198 156 126 104 88 75 64 56
General Information

#3 @ 9'' o.c. 0.147 295 226 178 144 119 100 85 74 64


4x4 - W4.0xW4.0 0.120 286 219 173 140 116 97 83 71 62
7 #4 @ 18'' o.c. 0.131 299 229 181 147 121 102 87 75 65
#3 @ 9'' o.c. 0.147 341 261 206 167 138 116 99 85 74
#4 @ 18'' o.c. 0.131 341 261 206 167 138 116 99 85 74
7 1/2 #3 @ 9'' o.c. 0.147 388 297 234 190 157 132 112 97 84
#4 @ 12'' o.c. 0.196 400 385 304 246 204 171 146 126 110
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
Code of Standard Practice

● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive steel
rests on deck and negative steel cover = 3/4''.
● Galvanized deck. If non-galvanized deck or temporary shoring is used, the weight of the slab must be deducted from the uniform loads.
● End span of three span condion and ACI moment coefficients.
● Slab deflecon is limited to a minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
108 www.newmill.com/digital-tools
3.0FD Form Deck

Table of Contents
NORMAL-WEIGHT CONCRETE
Form Decks - Type 3.0FD
PROPERTIES Optional run-out side lap for screws
Thickness Cover Weight 7 41 ˝ 12˝
Gage
(in) (in) (psf)
4 43 ˝
22 0.0295 1.71 3˝
20 0.0358 2.07
36 ICC-ES APPROVED
18 0.0474 2.74
36˝ Coverage REFER TO ESR-3818

Roof Deck
16 0.0598 3.45
ASD SECTION PROPERTIES DESIGN STRENGTHS (No Concrete Fill)
Fy ID 1 Span ID 2+ Span Ip In Sp Sn Mn,p/Ω Mn,n/Ω Vn/Ω *Rbe/Ω *Rbi/Ω
Gage
(ksi) (in4/ft) (in4/ft) (in4/ft) (in4/ft) (in3/ft) (in3/ft) (in-lb/ft) (in-lb/ft) (lb/ft) (lb/ft) (lb/ft)
22 40 0.770 0.770 0.764 0.750 0.407 0.424 9749 10151 1416 336 677
20 40 0.946 0.946 0.945 0.934 0.537 0.556 12871 13319 2227 482 967
18 40 1.253 1.253 1.252 1.253 0.794 0.802 19016 19213 3895 811 1615
16 40 1.580 1.580 1.579 1.579 1.012 1.013 24245 24264 4901 1245 2466
CONSTRUCTION CLEAR SPANS

Composite Deck
Total Slab Concrete Maximum Construction Conc. Notes:
Depth Gage Weight Clear Span (ft - in) Volume 1. Section properties are calculated in accordance with the
(in) (psf) Single Double Triple Cantilever (ft3/ft2) AISI S100-16.
2. Web crippling design strengths* and maximum construction
22 8 - 5 8 - 5 9 - 7 3 - 2
spans are based on 2 1/2'' for end bearing and 5'' for interior
20 10 - 11 11 - 7 12 - 0 4 - 0
5 42 0.292 bearing. Check web crippling if minimums are not met.
18 12 - 10 14 - 0 14 - 6 4 - 10 3. Maximum construction spans are based on ANSI/SDI
16 13 - 6 15 - 8 15 - 10 5 - 3 NC-2017 Standard for Non-Composite Steel Floor Deck
22 7 - 5 7 - 8 8 - 9 2 - 11 and the following construction loading:
20 10 - 4 10 - 11 11 - 6 3 - 10 ● Deck self-weight and concrete weight plus worst-case of

Versa-Dek®
5 1/2 48 0.333

Long-Span Composite
18 12 - 5 13 - 4 13 - 10 4 - 7
Normal Weight Concrete (145 pcf)

either a 150 lb. concentrated load or a 20 psf


16 13 - 1 15 - 0 15 - 5 5 - 1 uniform load; or
22 6 - 7 7 - 1 8 - 1 2 - 8 ● Deck self-weight plus a 50 psf uniform
20 9 - 11 10 - 1 11 - 0 3 - 8 construction load, whichever controls.
6 54 0.375
18 12 - 1 12 - 10 13 - 3 4 - 5 4. Concrete weights do not include weight of deck.

Deep-Dek®
16 12 - 9 14 - 4 14 - 10 4 - 11 5. Deck profile has been accounted for in determining concrete
22 5 - 11 6 - 7 7 - 5 2 - 5 volumes. Deck and support deflections have not been
20 9 - 6 9 - 4 10 - 7 3 - 6 included in concrete volumes or weights.
6 1/2 60 0.417 6. Cantilever clear spans assume adjacent clear span is at least
18 11 - 9 12 - 4 12 - 9 4 - 3
3 times longer than the cantilever clear span and no greater
16 12 - 5 13 - 10 14 - 4 4 - 9
than spans shown. Bearing width at perimeter support
22 5 - 5 6 - 1 6 - 9 2 - 3
assumed to be 5'' minimum. Contact New Millennium otherwise.
20 9 - 2 8 - 8 9 - 11 3 - 3
7 66 0.458
18 11 - 6 11 - 11 12 - 4 4 - 1

Form Deck
16 12 - 2 13 - 4 13 - 10 4 - 7
22 5 - 0 5 - 8 6 - 3 2 - 1
20 8 - 10 8 - 2 9 - 3 3 - 1
7 1/2 72 0.500
18 11 - 1 11 - 6 11 - 11 3 - 11
16 11 - 11 12 - 11 13 - 5 4 - 5
SLAB DESIGN - ALLOWABLE SUPERIMPOSED UNIFORM LOADS
Total Slab Reinforcement Allowable Superimposed Uniform Load (psf)
As
NWC (γc = 145 pcf, f'c = 3000 psi, n = 9, Fys = 60000 psi)

Depth, h (Mesh or Clear Span (ft - in)

Typical Fastener Layouts


2
(in /ft)
(in) Deformed Bars) 7 - 0 8 - 0 9 - 0 10 - 0 11 - 0 12 - 0 13 - 0 14 - 0 15 - 0
6x6 - W4.0xW4.0 0.080 91 70 55 45 37 31 26 23 20
5 4x4 - W2.9xW2.9 0.087 100 76 60 49 40 34 29 25 22
4x4 - W4.0xW4.0 0.120 134 103 81 66 54 46 39 34 29
4x4 - W2.9xW2.9 0.087 127 98 77 62 52 43 37 32 28
5 1/2 4x4 - W4.0xW4.0 0.120 172 132 104 84 70 59 50 43 37
#3 @ 9'' o.c. 0.147 202 154 122 99 82 69 58 50 44
4x4 - W4.0xW4.0 0.120 210 161 127 103 85 71 61 52 46
6 #4 @ 18'' o.c. 0.131 217 166 131 106 88 74 63 54 47
#3 @ 9'' o.c. 0.147 248 190 150 122 100 84 72 62 54
4x4 - W4.0xW4.0 0.120 248 190 150 121 100 84 72 62 54
6 1/2 #4 @ 18'' o.c. 0.131 258 198 156 126 104 88 75 64 56
General Information

#3 @ 9'' o.c. 0.147 295 226 178 144 119 100 85 74 64


4x4 - W4.0xW4.0 0.120 286 219 173 140 116 97 83 71 62
7 #4 @ 18'' o.c. 0.131 299 229 181 147 121 102 87 75 65
#3 @ 9'' o.c. 0.147 341 261 206 167 138 116 99 85 74
#4 @ 18'' o.c. 0.131 341 261 206 167 138 116 99 85 74
7 1/2 #3 @ 9'' o.c. 0.147 388 297 234 190 157 132 112 97 84
#4 @ 12'' o.c. 0.196 400 385 304 246 204 171 146 126 110
Notes: 7. Allowable Superimposed Uniform Loads shown are based on the following criteria:
● Unfactored service level loads, determined using ACI design method and uniform load factor of 1.6.
Code of Standard Practice

● Reinforcement placed at middle of tc for h ≤ 3''. For h > 3'', mesh is draped over supports or bars are placed for posive and negave bending, where posive steel
rests on deck and negative steel cover = 3/4''.
● Galvanized deck. If non-galvanized deck or temporary shoring is used, the weight of the slab must be deducted from the uniform loads.
● End span of three span condion and ACI moment coefficients.
● Slab deflecon is limited to a minimum of Clear Span/360 or 1'' under service level superimposed loading.

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 109
Typical Fastener Layouts
Table of Contents

Deck attachment patterns are designed by the engineer of record. The type of fastening
system used will depend on the uplift capacity, diaphragm shear capacity and the
thickness of the supporting members. The different types of systems that can be used
are power driven fasteners, arc spot welds, arc seam welds and self-drilling screws.
Roof Deck
Composite Deck
Deep-Dek®
Long-Span Composite
Versa-Dek®
Form Deck
Typical Fastener Layouts
General Information
Code of Standard Practice

Discover the easiest way to specify Steel Roof and Floor Deck:
110 www.newmill.com/digital-tools
Long-Span Composite
Table of Contents Roof Deck Composite Deck Form Deck Typical Fastener Layouts General Information Code of Standard Practice
Versa-Dek® Deep-Dek®

111
Typical Fastener Layouts

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools
Long-Span Composite
Code of Standard Practice General Information Typical Fastener Layouts Form Deck Composite Deck Roof Deck Table of Contents
Versa-Dek® Deep-Dek®

General
Information
Table of Contents
To ensure our customers realize a better steel experience, New Millennium
is committed to providing the best, most up-to-date information related
to steel roof and floor deck. Click on the links below to learn more.

Roof Deck
Floor Deck Design.................................................................................................... 114

Composite Deck
Web Crippling Support Reactions......................................................................115

Fire Resistance Ratings.......................................................................................... 116

Versa-Dek®
Long-Span Composite
Standard Accessory Details................................................................................. 117

Deep-Dek®
Floor Deck Accessory Details............................................................................... 118

Pour Stop Gage Selection..................................................................................... 119

Form Deck
Bill of Materials............................................................................................. 120 – 121

Factory Mutual Approved Steel Decks............................................................122

Typical Fastener Layouts


General Information
Code of Standard Practice

newmill.com 113
Floor Deck Design
Table of Contents

Floor Deck Design


The construction loading diagrams shown are from the ANSI/SDI NC NC-2017
2017 Standard
Standard for Non-Composite
Non Composite Steel Floor Deck and
ANSI/SDI C-2017
C 2017 Standard
Standard for Composite Steel Floor Deck-slabs.
Deck slabs. The moment diagrams represent the maximum bending
moment magnitudes resulting from loading applied in a sequence that simulates concrete placement. In addition to bending
and deflection shown below, due consideration shall be given to the effects of shear, bending and shear interaction, and web
crippling. The minimum construction Live Loads P and W2 shown shall be increased by the designer when anticipated
construction loading or methods will exceed the minimum value
values.
s. See the referenced ANSI/SDI standards for further notes and
Roof Deck

commentary. These
These diagrams should be used only for the design of the deck as a form. The concrete slab shall be designed in
accordance the ACI 318.

FORM & COMPOSITE DECK BENDING MOMENT LOADI


LOADING
NG DIAGRAMS
P = 150 lbs. concentrated Live Load
W1 = Slab weight + deck weight (psf)
Composite Deck

W2 = 20 psf uniform construction Live Load


L = Clear span length (ft)
Note: Live Loads P and W2 listed are minimums, increase when actual construction loads dictate.
Deep-Dek®
Long-Span Composite
Versa-Dek®

SINGLE SPAN CONDITION DOUBLE SPAN CONDITION TRIPLE SPAN CONDITION


Form Deck

FORM & COMPOSITE DECK DEFLECTION LOADING DIAGRAMS


4
I = Deck moment of inertia (in /ft)
W1 = Slab weight + deck weight (psf)
6
E = 29.5 x 10 (psi)
Typical Fastener Layouts

L = Clear span length (ft)

SINGLE SPAN CONDITION DOUBLE SPAN CONDITION TRIPLE SPAN CONDITION


General Information
Code of Standard Practice

Discover the easiest way to specify Steel Roof and Floor Deck:
114 www.newmill.com/digital-tools
Composite and Form Deck WebCrippling
Web Crippling Support
SupportReactions
Reactions

Table of Contents
P = 150 lbs. concentrated Live Load
W1 = Slab weight + deck weight (psf)
W2 = 20 psf uniform constr. Live Load
L = Clear span length (ft)
Note: Live Loads P and W2 listed are

Roof Deck
minimums, increase when actual
construction loads dictate.

SINGLE SPAN CONDITION DOUBLE SPAN CONDITION TRIPLE SPAN CONDITION

Composite Deck
ALLOWABLE REACTIONS AT EXTERIOR & INTERIOR SUPPORTS - ASD
Allowable Exterior (Rext) / Interior (Rint) Reaction (lbs/ft of width)
Fy
Type4 Gage3 Bearing Length (in)
(ksi)
1 1/2 2 2 1/2 3 3 1/2 4 4 1/2 5 5 1/2 6
28 583 / 838 640 / 910 640 / 910 640 / 910 640 / 910 640 / 910 640 / 910 640 / 910 640 / 910 640 / 910
0.6FD 26 811 / 1182 887 / 1278 887 / 1278 887 / 1278 887 / 1278 887 / 1278 887 / 1278 887 / 1278 887 / 1278 887 / 1278
60
0.6FDV 24 1352 / 2008 1470 / 2160 1470 / 2160 1470 / 2160 1470 / 2160 1470 / 2160 1470 / 2160 1470 / 2160 1470 / 2160 1470 / 2160

Versa-Dek®
Long-Span Composite
22 1984 / 2989 2149 / 3201 2149 / 3201 2149 / 3201 2149 / 3201 2149 / 3201 2149 / 3201 2149 / 3201 2149 / 3201 2149 / 3201
26 466 / 662 517 / 724 561 / 779 601 / 828 632 / 867 632 / 867 632 / 867 632 / 867 632 / 867 632 / 867
1.0FD 24 789 / 1149 870 / 1251 941 / 1341 1006 / 1422 1055 / 1483 1055 / 1483 1055 / 1483 1055 / 1483 1055 / 1483 1055 / 1483
60
1.0FDV 22 1169 / 1733 1285 / 1879 1387 / 2009 1479 / 2126 1548 / 2213 1548 / 2213 1548 / 2213 1548 / 2213 1548 / 2213 1548 / 2213

Deep-Dek®
20 1665 / 2504 1824 / 2707 1964 / 2886 2091 / 3047 2183 / 3165 2183 / 3165 2183 / 3165 2183 / 3165 2183 / 3165 2183 / 3165

1.5FD 22 654 / 962 719 / 1044 776 / 1116 827 / 1181 875 / 1240 881 / 1248 881 / 1248 881 / 1248 881 / 1248 881 / 1248
1.5FDR1 20 932 / 1393 1021 / 1506 1100 / 1606 1171 / 1696 1236 / 1779 1243 / 1787 1243 / 1787 1243 / 1787 1243 / 1787 1243 / 1787
40
1.5CD2 18 1557 / 2377 1698 / 2557 1822 / 2715 1934 / 2858 2037 / 2990 2043 / 2998 2043 / 2998 2043 / 2998 2043 / 2998 2043 / 2998
1.5CDR
16 2381 / 3693 2586 / 3955 2766 / 4187 2929 / 4396 3079 / 4589 3080 / 4590 3080 / 4590 3080 / 4590 3080 / 4590 3080 / 4590

Form Deck
22 292 / 458 321 / 497 347 / 531 370 / 562 391 / 590 411 / 617 429 / 641 447 / 665 463 / 687 479 / 709
2.0FD 20 419 / 662 459 / 716 494 / 763 526 / 806 556 / 845 583 / 882 608 / 916 633 / 949 656 / 979 678 / 1009
40
2.0CD 18 705 / 1128 769 / 1213 825 / 1288 876 / 1356 922 / 1419 966 / 1477 1007 / 1531 1045 / 1583 1082 / 1632 1117 / 1679
16 1083 / 1750 1176 / 1875 1258 / 1985 1333 / 2084 1401 / 2175 1464 / 2260 1524 / 2340 1580 / 2415 1634 / 2487 1685 / 2555
22 283 / 466 311 / 506 336 / 541 358 / 572 379 / 601 398 / 628 416 / 653 433 / 677 449 / 700 465 / 722
3.0FD 20 409 / 675 448 / 730 482 / 778 514 / 821 542 / 862 569 / 899 594 / 934 618 / 967 640 / 998 662 / 1029
40

Typical Fastener Layouts


3.0CD 18 694 / 1151 756 / 1238 811 / 1314 861 / 1384 907 / 1447 950 / 1507 990 / 1562 1028 / 1615 1064 / 1665 1099 / 1713
16 1071 / 1787 1164 / 1914 1245 / 2026 1318 / 2127 1386 / 2221 1449 / 2307 1508 / 2389 1563 / 2466 1616 / 2539 1667 / 2609
20 50 1146 / 1665 1256 / 1800 1352 / 1919 1439 / 2027 1513 / 2117 1513 / 2117 1513 / 2117 1513 / 2117 1513 / 2117 1513 / 2117
1.5CFDC
18 50 1913 / 2855 2086 / 3070 2239 / 3261 2377 / 3433 2490 / 3574 2490 / 3574 2490 / 3574 2490 / 3574 2490 / 3574 2490 / 3574
1.5CFDCA
16 40 2338 / 3557 2539 / 3810 2716 / 4033 2876 / 4234 3004 / 4395 3004 / 4395 3004 / 4395 3004 / 4395 3004 / 4395 3004 / 4395
20 50 533 / 838 584 / 906 629 / 966 669 / 1020 707 / 1070 741 / 1116 774 / 1160 805 / 1201 834 / 1240 851 / 1263
2.0CFDC
18 50 894 / 1425 975 / 1533 1046 / 1628 1111 / 1714 1170 / 1793 1225 / 1867 1277 / 1936 1326 / 2001 1373 / 2063 1399 / 2098
2.0CFDCA
16 40 1097 / 1767 1191 / 1893 1274 / 2004 1349 / 2104 1419 / 2196 1483 / 2281 1543 / 2362 1600 / 2438 1655 / 2510 1684 / 2549
20 50 529 / 870 580 / 940 625 / 1002 665 / 1058 702 / 1110 737 / 1158 769 / 1203 800 / 1246 829 / 1287 857 / 1325
General Information
3.0CFDC
18 50 896 / 1481 977 / 1593 1049 / 1692 1113 / 1781 1173 / 1863 1228 / 1940 1280 / 2011 1329 / 2079 1376 / 2144 1420 / 2205
3.0CFDCA
16 40 1106 / 1838 1201 / 1969 1285 / 2084 1361 / 2189 1430 / 2284 1495 / 2374 1556 / 2457 1614 / 2537 1668 / 2612 1721 / 2684
1
Reaction values indicated also apply to types 1.5FDI, 1.5FDV and 1.5FDIV.
2
Reaction values indicated also apply to type 1.5CDI.
3
Gages shown for cellular and cellular acoustical deck types, indicate gage of top (fluted) section. Bottom (flat) section is not considered in web crippling calculation.
4
For form and composite deck types not listed here, refer to ICC-ES Reports ESR-1169, ESR-2635 and ESR-2839 for published allowable support reactions.
Code of Standard Practice

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 115
Fire Resistance Ratings
Table of Contents

New Millennium deck products are approved for use in UL fire rated assemblies. Please visit UL/ULC Online Certifications
Directory, UL/ULC File Numbers R20577 and R22282 (links provided below) for an up-to-date listing of UL/ULC Designs in which
New Millennium deck products have been approved. UL design numbering system has been provided below for your use in
navigating to the specific construction types required for your project.

NUMBERING SYSTEM FOR UL DESIGNS


Roof Deck

Floors - Ceilings
Refer to UL report CHWX.R20577
CHWX.R20577 for New Millennium deck types.

D200-299: Concrete on steel deck w/exposed grid system


D300-399: Concrete on steel deck w/mineral or fiber board
D500-599: Concrete on steel deck w/gypsum board
Composite Deck

D700-899: Concrete on steel deck w/spray-applied fire-resistive material


D900-999: Concrete on steel deck w/no protection
E700-899: Concrete on steel deck w/spray-applied fire-resistive material
E900-999: Concrete on steel deck w/no protection
G200-299: Concrete on steel deck & steel joists w/exposed grid system
Deep-Dek®
Long-Span Composite

G500-599: Concrete on steel deck & steel joists w/gypsum board


G700-899: Concrete on steel deck & steel joists w/spray-applied fire-resistive material
Type 3.5VLSC in Joint System Design No. HW-S-0127
Versa-Dek®

L700-899: Wood on steel deck w/spray-applied fire-resistive material


N700-899: Concrete on steel deck & steel joists w/spray-applied fire-resistive material
Roof - Ceiling
Refer to UL report CHWX.R20577
CHWX.R20577 for New Millennium deck types.
Form Deck

P200-299: Steel deck w/exposed grid system


P400-499: Steel deck w/metal lath
P500-599: Steel deck w/gypsum board
P700-899: Steel deck w/spray-applied fire-resistive material
P900-999: Steel deck w/no protection
Typical Fastener Layouts

Floors - Ceilings
Refer to UL report CJFS.R22282
CJFS.R22282 for New Millennium deck types.

D900-999: Concrete on steel deck (as structural framing member) w/no protection
L500-599: Wood on steel deck (as structural framing member) w/gypsum board
Floors - Ceilings (Canada)
Refer to ULC report CHWXC.R20577
CHWXC.R20577 for New Millennium deck types.
General Information

F700-799: Concrete on steel deck w/spray-applied fire-resistive material – cementitious


F800-899: Concrete on steel deck w/spray-applied fire-resistive material – sprayed fibre
F900-999: Concrete on steel deck w/no protection
Code of Standard Practice

Discover the easiest way to specify Steel Roof and Floor Deck:
116 www.newmill.com/digital-tools
Standard
Standard Accessories
Accessories
Standard & Roof
& Roof
Accessories Accessory
Accessory
& Roof Details
Details
Accessory Details

Table of Contents
STANDARDDECK
STANDARD DECKACCESSORIES
ACCESSORIES A (7") 3378"
STANDARDDECK
STANDARD DECKACCESSORIES
ACCESSORIES B A (7") 3378"
28"
Notes: B Std. Dims: 28"
Notes:
1. Accessories are furnished with G60 galvanized C (12") Std. Dims:
FS1: B = 112"
1. Accessories are furnished 1
coating minimum, in 10'-0"with G60 galvanized
lengths. C (2") FS2: B = 13"12"
FS1:
2. coating
Standardminimum, in 10'-0"
accessories are 20lengths.
gage - U.N.O. FS2: B = 3"
2. Standard
3. New accessories
Millennium are 20 gage
can provide - U.N.O.
special light-gage
3. New Millennium
accessories canyour
to meet provide special
project light-gage
requirements, FILLER SHEET - B & N (FSx)

Roof Deck
accessories to meet
including notched oryour projectPour
reinforced requirements,
Stops and FILLER SHEET - B & N (FSx)
including notched
accessories or 304
made of reinforced Pour
stainless Stops
steel. and
Contact
Std. Dims:

" 78"
24"24"
accessories
New madefor
Millennium of availability
304 stainlessandsteel. Contact
pricing. A
B (112")
1

297829
New Millennium for availability and pricing. Std.
GF3:Dims:
A = 4" (3" Gap) A
GF3:
GF6: A = 4"
7",(3"
14 Gap)
Ga. (6" Gap) B 2")
(1
C (153°) GF6:
GF9: A = 7",
10",1414Ga.
Ga.(6"
(9"Gap)
Gap) 14 Ga.
Std. Dims: C (153°) GF9:
GF12:AA= =10",
13",1412Ga.
Ga.(9" Gap)
(12" Gap) 14 Ga.
Std. Dims:
RVP1: A & B = 412" A B GF12:
ContactA =New
13",Millennium
12 Ga. (12"for
Gap)
gage reqmts.
RVP2: A & B = 46"12"
RVP1: A B Contact New
when total NWMillennium for gage
concrete slab reqmts.
exceeds 12"

Composite Deck
RVP2: A & B = 6" when total NW concrete slab exceeds 12"
RIDGE/VALLEY PLATE (RVPx) GIRDER FILLER (GFx)
RIDGE/VALLEY PLATE (RVPx) GIRDER FILLER (GFx)

121"121"
A (1") A (112") RECESSED SUMP PAN (SUMP)
A (1") A (112")Std. Dims: RECESSED SUMP PAN (SUMP)
Std. Dims: Std. Dims:
A Std. Dims:
FP6: A = 6" B B
Std.
ZC1:Dims:
B = 112" Std.
ZEE1:Dims:
B = 2"
A FP9: A = 6"
FP6: 9" B B MISC. STOCK ITEMS
ZC2: B = 12"12"
ZC1: ZEE1:
ZEE2: B = 2"
312"
FP12:AA= =9"12", 18 Ga.
FP9: C (1") ZC3: B = 2"
ZC2: 3" C (Specify)
ZEE2: B = 312" MISC. STOCK #10-16
10-1/10-1FM: ITEMS x 3" Type 1 Side Lap Screw
C (1") C (Specify) 4
FP12: A = 12", 18 Ga.

Versa-Dek®
3

Long-Span Composite
ZC3: B = 3" 10-3/10-3FM: #10-16 xX 443"" Type
10-1/10-1FM: Type 13 Side
Side Lap
Lap Screw
Screw
FLAT PLATE (FPx) Z CLOSURE (ZCx) ZEE CLOSURE - VERSA (ZEEx) 10-3/10-3FM: 3
#12-14 X 443" Type 3 Side Lap Screw
12-3/12-3FM: #10-16
FLAT PLATE (FPx) Z CLOSURE (ZCx) ZEE CLOSURE - VERSA (ZEEx) 12-3/12-3FM: 3
#12-24 X 41"14"Type
12-5/12-5FM: #12-14 Type3 5Side Lap Screw
Support Screw
12-5/12-5FM:
COL: 12" x 24"#12-24 X 114Plate
x 20 Gage " TypeColumn
5 Support Screw
Closure
Std. Dims: COL:
or 27"12" x 24"
x 96" x 20Lath-Type
Metal Gage PlateColumn
ColumnClosure*
Closure

Deep-Dek®
B (1") Std. Dims:
PS1: A = 3" or
WW:27"Weld
x 96"Washer
Metal Lath-Type Column
w/ 83" Ø Hole, Closure*
16 Ga.
C C

Std. Dims:
1 ") 1 ")
(2 (2

B (1") Std. Dims: B (1") PS1: 312"


PS2: A = 3" *WW:
OnlyWeld Washer
Available w/ 83" Ø Facilities
at Certain Hole, 16 Ga.
A Std.
SC1:Dims:
A = 112" A
B (1") Std.
CC1:Dims:
A = 112" A PS3: A = 34"12"
PS2: * Only Available at Certain Facilities
A SC2: A = 12"12"
SC1: 412", 18 Ga.
PS4: A = 4"
PS3:
A CC2: A = 12"12"
CC1: MISC. SPECIAL ITEMS**
SC3: A = 2"
C (1") SC2: 3" B (5") 1
PS5: A = 45",
A CC3: A = 2"
CC2: 3" PS4: 2",1818Ga.
Ga. MISC.
PiercingSPECIAL ITEMS**
& Non-Piercing Hanger Tabs
CC3: A = 3" C (1") SC3: A = 3" B (5") PS5: A = 5", 18 Ga.
Piercing & Non-Piercing
Top/Bottom Side FlexibleHanger Tabs
Rubber Closures
CELL CLOSURE (CCx) SIDE CLOSURE (SCx) POUR STOP (PSx) Top/Bottom
** SidebyFlexible
Not supplied Rubber Closures
New Millennium
CELL CLOSURE (CCx) SIDE CLOSURE (SCx) POUR STOP (PSx)

Form Deck
** Not supplied by New Millennium

ROOF DECK
ROOF DECKACCESSORY
ACCESSORYINSTALLATION
INSTALLATION DETAILS
DETAILS
ROOF DECK
ROOF DECKACCESSORY
ACCESSORYINSTALLATION
INSTALLATION DETAILS
DETAILS
Note:
Note:
1. Accessories shall be attached to supporting structure or deck as required
1. Accessories shall be
for serviceability, butattached to supporting
spaced not structure
to exceed criteria or deck
shown as required
in details.
for serviceability, but spaced not to exceed criteria shown in details.

Typical Fastener Layouts


Fasten @ 24" o.c. Flat Plate Fasten @ 24" o.c. Ridge/Hip Plate
Fasten @ 24" o.c. Flat
Mk: Plate
FPx Fasten @ 24" o.c. Ridge/Hip
Mk: RVPx Plate
Mk: FPx Mk: RVPx

Fasten @ 24" o.c.


Fasten @ 24" o.c.
General Information

Fasten @ 24" o.c. Valley Plate


Fasten @ 24" o.c. Valley
Mk: Plate
RVPx
Mk: RVPx
Code of Standard Practice

Filler Sheet
Filler
Mk: FSxSheet
Mk: FSx

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 117
Floor Deck Accessory Details
Floor Deck Accessory Details
Table of Contents

FLOOR
FLOORDECK
DECKACCESSORY
ACCESSORYINSTALLATION DETAILS
INSTALLATION DETAILS
Note:
1. Accessories shall be attached to supporting structure or deck as required
for serviceability, but spaced not to exceed criteria shown in details.
Pour Stop 1" long welds Fasten @ 24" o.c. Cell Closure
Mk: PSx @ 12" o.c. Mk: CCx
Roof Deck

Overhang 2" min.


Composite Deck

Side Closure Weld @ 24" o.c. Fasten as required Cell Closure Mk: CCx
Mk: SCx (24" o.c. max.) Field cut at down ribs if interference
with shear stud installation occurs
Deep-Dek®
Long-Span Composite

Field Cut
Versa-Dek®

Weld @ 24" o.c. Girder Filler Weld @ 24" o.c. Fasten to support "Z" Closure
Mk: GFx & deck @ 24" o.c. Mk: ZCx
Form Deck

Gap
Typical Fastener Layouts

Use Cell Closure Mk: CCx


to cover open ribs
General Information

ROLLED-IN HANGER TAB DETAIL


Column Closure Mk: COL
(2) 12" x 24" x 20 Gage Plates (field cut to fit) Single tab capacity = 100 lbs.
OR (2) 16" x 27" Mesh Closures (field cut from Available in deck types B, BA, BI,
27" x 96" sheet). Tack weld to column. Fasten BIA, 1.5FDR, 1.5FDI, 2.0FD, 3.0FD,
1.5CD, 1.5CDI, 2.0CD, 3.0CD
Code of Standard Practice

to deck @ 12" o.c.

COLUMN CLOSURE DETAIL

Discover the easiest way to specify Steel Roof and Floor Deck:
118 www.newmill.com/digital-tools
Pour Stop GagePour
Selection
Stop Gage Selection

Table of Contents
GAGE SELECTION TABLE
Pour Stop Gage
Slab Depth
Overhang (in)
(in)
0 1 2 3 4 5 6 7 8 9 10 11 12
4 20 20 20 20 18 18 16 14 12 12 12 10 10
4 1/4 20 20 20 18 18 16 16 14 12 12 12 10 10

Roof Deck
4 1/2 20 20 20 18 18 16 16 14 12 12 12 10 10
4 3/4 20 20 18 18 16 16 14 14 12 12 10 10 10
5 20 20 18 18 16 16 14 14 12 12 10 10
5 1/4 20 18 18 16 16 14 14 12 12 12 10 10
5 1/2 20 18 18 16 16 14 14 12 12 12 10 10
5 3/4 20 18 16 16 14 14 12 12 12 12 10 10
6 18 18 16 16 14 14 12 12 12 10 10 10

Composite Deck
6 1/4 18 18 16 14 14 12 12 12 12 10 10
6 1/2 18 16 16 14 14 12 12 12 12 10 10
6 3/4 18 16 14 14 14 12 12 12 10 10 10
7 18 16 14 14 12 12 12 12 10 10 10
7 1/4 16 16 14 14 12 12 12 10 10 10
7 1/2 16 14 14 12 12 12 12 10 10 10
7 3/4 16 14 14 12 12 12 10 10 10 10

Versa-Dek®
Long-Span Composite
8 14 14 12 12 12 12 10 10 10
8 1/4 14 14 12 12 12 10 10 10 10
8 1/2 14 12 12 12 12 10 10 10
8 3/4 14 12 12 12 12 10 10 10

Deep-Dek®
9 14 12 12 12 10 10 10
9 1/4 12 12 12 12 10 10 10
9 1/2 12 12 12 10 10 10
9 3/4 12 12 12 10 10 10
10 12 12 10 10 10 10 DESIGN THICKNESS

Form Deck
10 1/4 12 12 10 10 10 Thickness
Gage
10 1/2 12 12 10 10 10 (in)
10 3/4 12 10 10 10 20 0.0358
11 12 10 10 10 18 0.0474
11 1/4 12 10 10 16 0.0598
11 1/2 10 10 10 14 0.0747

Typical Fastener Layouts


11 3/4 10 10 12 0.1046
12 10 10 10 0.1345
Notes:
1. Gages shown above are based on the following criteria:
● Pour stop must be supported for its full length
● Normal weight concrete (145 pcf)
● Horizontal and vercal deflecon is limited to 1/4" maximum under concrete dead load Pour Stop 1" long welds
● Design stress is limited to 20 ksi for concrete dead load temporarily increased by one-third for
@ 12" o.c.
the construction live load of 20 psf.
2. The gage selection table above does not consider the effect of the performance, deflection or rotation
of the pour stop support which may include both the supporting deck and/or the framing member. General Information
3. A vertical leg return lip is recommended for all gages.
4. This selection table is not meant to replace the judgement of the Design Professional and shall be
considered as reference only.
5. Reinforced Pour Stop can be designed and supplied where slab edge condition exceeds table.
Contact New Millennium for assistance.

Overhang 2" min.


Code of Standard Practice

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 119
Bill of Materials
Table of Contents

SALESSALES
FAX FAX
BUTLER,
BUTLER, IN (260)IN868-6002
(260) 868-6002
FALLON,
FALLON, NV867-2140
NV (775) (775) 867-2140
HOPE,
HOPE, AR AR722-4262
(870) (870) 722-4262
JUAREZ,
JUAREZ, MX298-4040
MX (915) (915) 298-4040
LAKEFL
LAKE CITY, CITY, FL466-1302
(386) (386) 466-1302
WWW.NEWMILL.COM
WWW.NEWMILL.COM SALEM,SALEM, VA389-0378
VA (540) (540) 389-0378
Roof Deck

https://www.newmill.com/resources/bills-of-materials.html MEMPHIS,
MEMPHIS, TN375-1547
TN (901) (901) 375-1547

DATE:DATE:
DECK
DECK BILL
BILL OF MATERIAL
OF MATERIAL
SHEET:
SHEET: of of
JOB NAME:
JOB NAME: CUST.
CUST. JOB #: JOB #: NMBS
NMBS JOB #: JOB #:
LOCATION:
LOCATION: DETAILER:
DETAILER: CHECKER:
CHECKER:

SEQ.: SEQ.: SEQ.: SEQ.: SEQ.: SEQ.:


Composite Deck

TYPE: TYPE: GAGE: GAGE: TYPE: TYPE: GAGE: GAGE: TYPE: TYPE: GAGE: GAGE:
COVERAGE:
COVERAGE: FINISH:FINISH: COVERAGE:
COVERAGE: FINISH:FINISH: COVERAGE:
COVERAGE: FINISH:FINISH:

QTY. QTY. LENGTH


LENGTH BUNDLE
BUNDLE # # QTY. QTY. LENGTH
LENGTH BUNDLE
BUNDLE # # QTY. QTY. LENGTH
LENGTH BUNDLE
BUNDLE # #
Deep-Dek®
Long-Span Composite
Versa-Dek®
Form Deck
Typical Fastener Layouts

TOTALTOTAL PIECES:
PIECES: TOTALTOTAL PIECES:
PIECES: TOTALTOTAL PIECES:
PIECES:
TOTALTOTAL SQUARES:
SQUARES: TOTALTOTAL SQUARES:
SQUARES: TOTALTOTAL SQUARES:
SQUARES:
General Information

WELD WASHERS:
WELD WASHERS: WELD WASHERS:
WELD WASHERS: WELD WASHERS:
WELD WASHERS:
SCREWS:
SCREWS: SCREWS:
SCREWS: SCREWS:
SCREWS:
SUMP PANS:
SUMP PANS: SUMP PANS:
SUMP PANS: SUMP PANS:
SUMP PANS:
REMARKS:
REMARKS:
Code of Standard Practice

Discover the easiest way to specify Steel Roof and Floor Deck:
120 www.newmill.com/digital-tools
Bill of Materials

Table of Contents
SALES FAX
SALES FAX
BUTLER, IN (260) 868-6002
BUTLER, IN (260) 868-6002
FALLON, NV (775) 867-2140
FALLON, NV (775) 867-2140
HOPE, AR (870)AR
HOPE, 722-4262
(870) 722-4262
JUAREZ,JUAREZ,
MX (915)MX 298-4040
(915) 298-4040
LAKE CITY,
LAKEFL CITY,
(386)FL
466-1302
(386) 466-1302
WWW.NEWMILL.COM
WWW.NEWMILL.COM SALEM, VA (540)VA
SALEM, 389-0378
(540) 389-0378

Roof Deck
https://www.newmill.com/resources/bills-of-materials.html MEMPHIS, TN (901)TN
MEMPHIS, 375-1547
(901) 375-1547

DATE: DATE:
DECK ACCESSORY BILL OF
DECK ACCESSORY MATERIAL
BILL OF MATERIAL
SHEET:SHEET: of of
JOB NAME: JOB NAME: CUST. JOBCUST.
#: JOB #: NMBS JOB#:
NMBS JOB#:
LOCATION: LOCATION: DETAILER:DETAILER: CHECKER:
CHECKER:

Composite Deck
Ridge/Valley Plate (RVPx) Side Closure (SCx) Cell Closure (CCx) Flat Plate (FPx) Filler Sheet (FSx)
Ridge/Valley Plate (RVPx)
Stock Dims: Side Closure (SCx)
Stock Dims: Cell Closure (CCx)
Stock Dims: Flat PlateStock
(FPx)Dims: Filler Sheet
Stock(FSx)
Dims:
Stock Dims: Stock Dims:
RVP1: A & B = 4 1/2", C = 153º SC1: A = 1 1/2", B&C = Stock
1" Dims: CC1: A = 1 1/2", B =Stock1" Dims:FP6: A = 6" Stock Dims:FS1: B = 1 1/2"
RVP2:
RVP1: A & B = 4 1/2", A 153º
C= & B = 6", C = 153º SC1: A = 1 1/2",SC2:
B&CA==1" CC2:
2", B&C = 1" CC1: A = 1 1/2", BA= =1"2", B = 1" FP6: A = 6"FP9: A = 9" FS1: B = 1FS2:
1/2"B = 3"
RVP2: A & B = 6", C = 153º SC3:
SC2: A = 2", B&C A = 3", B&C = 1" CC2: A = 2", B
= 1" CC3:
= 1"A = 3", B = 1" FP9: A = 9"FP12: A = 12", 18 Ga. FS2: B = 3"
SC3: A = 3", B&C = 1" CC3: A = 3", B = 1" FP12: A = 12", 18 Ga.
Notes: All Accessories are 20 gage - U.N.O.
All Accessories
Notes: All Accessories are 20 gageare- U.N.O.
furnished in 10' lengths
All Accessories
All Accessories are in
are furnished G60
10'Galvanized
lengths - Min.
All Stockare
Accessories Items:
G60 Galvanized - Min.
Pour Stop (PSx) Zee Closure (Zx) Girder Filler (GFx)
Stock Dims: Stock Dims: Stock Items:
10-1: #10-16 x 3/4" Type 1 Side Lap
Pour Stop (PSx) Zee Closure (Zx) Girder Filler (GFx)

Versa-Dek®
Long-Span Composite
PS1: A = 3", B = 5" 10-3: #10-16
Typex 13/4" Type
Lap3 Side Lap
Stock Dims: PS2: A = 3 1/2", B = 5" Stock Dims: GF3: A = 4" 10-1: #10-16 x 3/4" Side
12-3: #12-14 x 3/4" Type 3 Side Lap
PS1: A = 3", B = 5" GF6: A = 7", 14 Ga. 10-3: #10-16 x 3/4" Type 3 Side Lap
PS3: A = 4", B = 5" GF3: A = 4" GF9: A = 10", 14 Ga. 12-5: #12-24 x 1 1/4" Type 5 Deck Attachment Screw
PS2: A = 3 1/2", BPS4:
= 5" A = 4 1/2", B = 5", 18 Ga GF6: A = 7", 14 Ga. A = 13", 12 Ga. 12-3: #12-14 x 3/4" Type 3 Side Lap
PS3: A = 4", B = 5" GF12: COL: 12" x 24" Column Closure
PS5: A = 5", B = 5", 18 Ga GF9: A = 10", 14 Ga. 12-5: #12-24 x 1 1/4" Type 5 Deck Attachment Screw
PS4: A = 4 1/2", B = 5", 18 Ga SUMP: 30" x 34" x 14 Gage Standard Sump Pan
GF12: A = 13", 12 Ga. COL: 12" x 24" Column Closure
PS5: A = 5", B = 5", 18 Ga WW: Standard Weld Washer
SUMP: 30" x 34" x 14 Gage Standard Sump Pan
DIMENSIONS WW: Standard Weld Washer

Deep-Dek®
MARK QTY. GAGE REMARKS SEQUENCE
DIMENSIONS
A B C
MARK QTY. GAGE REMARKS SEQUENCE
A B C

Form Deck
Typical Fastener Layouts
General Information
Code of Standard Practice

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 121
Factory Mutual Approved Steel Decks
Table of Contents

New Millennium Building Systems steel roof deck types F (intermediate rib – IR), B (wide rib – WR) and
N (deep rib – DR) are approved for use as a component of Factory Mutual compliant roof systems. New
Millennium decks have been approved in accordance with Factory Mutual, Approval Standard for Steel
Deck as Component of Class 1 Insulated Steel Roof Deck Construction, Class Number 4451 revised 6/2012.
Reference the following tables for approved gages, maximum allowed center-to-center spans and securement
Roof Deck

requirements for Classes 1-60, 1-75 and 1-90. The securement of the roof system must be enhanced at the
building corners and perimeter as outlined in FM Global Property Loss Prevention Data Sheet 1-29.

To ensure availability of material and avoid delays to your project, New Millennium must be informed as early in
the contract process as possible when steel with a minimum yield stress of 80 ksi is determined to be a requirement
by the design professional to satisfy Factory Mutual Data Sheet 1-29, Section 2.2.3, Steel Roof Deck. One of
the design considerations that may require the higher strength steel is when a rating higher than 1-90 is needed.
Composite Deck

Consult the Section noted above for other conditions that may also result in the necessity of this requirement.

F Deck

Type F - Factory Mutual Maximum Ctr. to Ctr. Spans (ft. - in.)


Deep-Dek®
Long-Span Composite

FM Class 1 - 60 1 - 75 1 - 90

Deck Gage 22 20 18 16 22 20 18 16 22 20 18 16

Single Span 4-4 5-5 6-5 7-3 4-4 5-5 6-5 7-3 4-4 5-5 6-5 7-3
Versa-Dek®

Double Span 5-3 6-6 7-7 8-6 5-3 6-6 7-7 8-6 5-3 6-6 7-7 8-4

Triple Span 5-4 6-7 7-7 8-6 5-4 6-7 7-7 8-6 5-4 6-7 7-7 8-6

B Deck
Form Deck

Type B - Factory Mutual Maximum Ctr. to Ctr. Spans (ft. - in.)


FM Class 1 - 60 1 - 75 1 - 90

Deck Gage 22 21 20 19 18 16 22 21 20 19 18 16 22 21 20 19 18 16

Single Span 5 -11 6-3 6-7 7-1 7-7 8-6 5 -11 6-3 6-7 7-1 7-7 8-6 5 -11 6-3 6-7 7-1 7-7 8-6

Double Span 7-0 7-5 7-9 8-4 8 - 11 10 - 0 7-0 7-5 7-9 8-4 8 - 11 10 - 0 7-0 7-5 7-9 8-4 8 - 11 10 - 0
Typical Fastener Layouts

Triple Span 7-0 7-5 7-9 8-4 8 - 11 10 - 0 7-0 7-5 7-9 8-4 8 - 11 10 - 0 7-0 7-5 7-9 8-4 8 - 11 10 - 0

N Deck

Type N - Factory Mutual Maximum Ctr. to Ctr. Spans (ft. - in.)


FM Class 1 - 60 1 - 75 1 - 90

Deck Gage 22 21 20 19 18 16 22 21 20 19 18 16 22 21 20 19 18 16
General Information

Single Span 12 - 8 14 - 3 14 - 11 16 - 1 17 - 2 19 - 3 12 - 4 13 - 3 14 - 0 15 - 3 16 - 3 18 - 3 11 - 3 12 - 1 12 - 9 13 - 11 14 - 10 16 - 8

Double Span 13 - 0 14 - 0 14 - 11 16 - 3 17 - 5 19 - 10 11 - 7 12 - 6 13 - 4 14 - 7 15 - 7 17 - 9 10 - 7 11 - 5 12 - 2 13 - 3 14 - 3 16 - 3

Triple Span 14 - 6 15 - 8 16 - 8 18 - 2 19 - 6 22 - 3 13 - 0 14 - 0 14 - 11 16 - 3 17 - 5 19 - 10 11 - 10 12 - 10 13 - 7 14 - 10 15 - 11 18 - 2
Code of Standard Practice

Discover the easiest way to specify Steel Roof and Floor Deck:
122 www.newmill.com/digital-tools
Code of Standard Practice

Table of Contents
Steel decks are considered a structural component of roof and floor systems. Aesthetic conditions
that do not affect the structural performance of the steel deck such as oil canning, minor denting
and damage to shop primer or surface coatings shall not be cause for rejection.

Oil canning (waviness in flat surfaces) is an inherent condition with steel decks that can occur

Roof Deck
during the forming process or from improper installation, especially in lighter gages.

For additional information, reference the Steel Deck Institute’s Code of Standard Practice,
SDI COSP-2017, Section 3.1 and Commentary to SDI COSP-2017, Sections C-3.1.1 and C-3.1.2.

Composite Deck
Below is a link to the Code of Standard Practice
as recommended by the Steel Deck Institute.

Code of Standard Practice for Steel Deck:

Versa-Dek®
Long-Span Composite
https://www.sdi.org/publications-2/publications/

Deep-Dek®
Form Deck
Typical Fastener Layouts
General Information
Code of Standard Practice

Discover the easiest way to specify Steel Roof and Floor Deck:
www.newmill.com/digital-tools 123
Building success together
New Millennium is your nationwide resource for the broadest range of
cost-optimized, high-performance structural steel joist and deck solutions.

• Structural steel joists, Joist Girders and deck • BIM-based steel joist and deck design
• Architectural decking solutions • Nationwide manufacturing and availability
• Multi-story long-span composite systems • Design-Build and Integrated Project Delivery (IPD)
• Custom engineering and design assistance • AIA and PDH courses for project optimization

Butler, Indiana Facility Fallon, Nevada Facility Hope, Arkansas Facility Juarez, Mexico Facility
6115 County Road 42 8200 Woolery Way 3565 Highway 32 North Carretera Panamericana 9920
Butler, IN 46721 Fallon, NV 89406 Hope, AR 71801 Colonia Puente Alto 32695
Phone: 260.868.6000 Phone: 775.867.2130 Phone: 870.722.4100 Cd. Juarez, Chihuahua
Fax: 260.868.6001 Fax: 775.867.2169 Fax: 870.722.4245 Phone: 915.298.5050
Fax: 915.298.4040
Lake City, Florida Facility Memphis, Tennessee Facility Salem, Virginia Facility
1992 NW Bascom Norris Drive 4900 Hungerford Road 100 Diuguids Lane Headquarters
Lake City, FL 32055 Memphis, TN 38118 Salem, VA 24153 1690 Broadway
Phone: 386.466.1300 Phone: 901.969.3033 Phone: 540.389.0211 Building 19, Suite 160
Fax: 386.466.1301 Fax: 901.375.1547 Fax: 540.389.0378 Fort Wayne, IN 46802
Phone: 260.321.8080

© 2023 New Millennium Building Systems, LLC All rights reserved.


New Millennium Building Systems is a wholly owned subsidiary of Steel Dynamics Inc.

You might also like