Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

DRAWING SCALE

PVF-120 NO SCALE
MEP & Architectural Design
1759 Vergueiro Street - 11º Floor
São Paulo - SP
+55 (11) 5594-0367
www.deerns.com
GENERAL SHEET NOTES
1.
2.
MEASUMERENTS IN CENTIMETERS
CHECK THE TECHNICAL SPECIFICATIONS AND CONSTRUCTIVE FOR
MARQUEZIN
PROJETOS ESTRUTURAIS E CONSULTORIA
marquezin@marquezin.com.br
DRAINAGE DESIGN. www.marquezin.com.br
+55 (43) 3029-1970
3. THE MANSORY LINTELS MUST BE EXECUTED EVERY 3 BRICK ROWS MAXIMUM. Londrina - Paraná

4. STRUCTURAL PAD WITH fck ≥ 4,5 MPa.


5. THE STILTS REINFORCEMENT MUST BE ANCHORED ON THE BOTTOM SLAB.
6. INTERNAL COATING (e=2,0cm) OF THE BOX WITH MORTAR OF SAND AND
CEMENT 1:3 RATIO. 60 Werner Sack Street
São Paulo - SP
7. STEEL CA-50.
+55 (11) 3877-0728
LID F°F° 8. REINFORCEMENT COATING = 3,0 cm (MIMINUM). www.ceg.eng.br
LID F°F° PATTERN C250. 9. STRUCTURAL CONCRETE fck ≥ 30 MPa. ENGENHARIA
10. LEAN CONCRETE fck ≥ 15 MPa.
PATTERN C250. C.T.
B C.T. 50 California Street
Suite 1500
STILTS:
TEECOM

20
San Francisco, CA
STRUCTURAL BRICK FILL
94111

20
19 121 19 WITH CONCRETE fck >=30 MPa AND STILTS:
(510) 337 2800

VAR. 15
4 Ø 12,5 mm (SEE NOTE 05) FILLED BRICKS
CONCRETE FILLING www.teecom.com

15
WITH CONCRETE II

I
I

I
MAXIMUM THICKNESS 19cm fck >= 30 MPa AND
I

I
SLAB

VAR.
4 Ø12,5mm (SEE NOTE 05) 4700 SE International Way
SLAB PRE-MOLDED

19
CONCRETE FILLING Milwaukie, Oregon 97222
PRE CAST T: 503-659-1240
THICKNESS MAXIMA 19cm
WIRELESS SYSTEMS www.daywireless.com
HYPERLINK
"tel:+15036591240"

E
D
U SHAPED BRICKS:

A
R
GUTTER BRICK

G
N
H

O
FILLED WITH

B
Hb

LA
CONCRETE

S
fck >= 30 MPa

121

Hb
WITH 2 Ø12,5mm
A A (SEE NOTE 03)
2815 Eastlake Ave. East Ste. 300, Seattle, Washington, 98102
T: 425-830-1164
CONCRETE BRICK
39 x 19 x 19 cm
1 World Wide Way
STILTS: Maryland Heights
STRUCTURAL BRICK FILL
C.F. 10 10 Missouri 63146

19
WITH CONCRETE fck >=30 MPa AND United States
2 Ø 12,5 mm (SEE NOTE 05) T: 314-569-7000
World WideTechnology www.wwt.com

15
15
B

5
CONCRETE BRICK HDPE PIPE
350 João XXIII Av. 65 - Mogi das Cruzes - SP

5
39 x 19 x 19 cm
BOX PLAN
LEAN CONCRETE imper T: +55 (11) 96310-0945
fck >= 15 MPa
TYPICAL MASONRY DETAIL SOLUTIONS http://www.impersolutions.com.br
LEAN CONCRETE SEXTION B-B PRE CAST SLAB PROJETOS, PESQUISA E CONSULTORIA
maressa.menezes@impersolutions.com.br
SECTION A-A fck >= 30 MPa

PRE CAST SLAB PEDRO PORTELA


ARQUITETURA E LUMINOTÉCNICA

C
P P

CPQ07
DATA CENTER
1995 PEDRINA GUILHERME
MUNICIPAL ROAD

Design Team

Design Luciano Campos / CEG

Drawn Nicky Barros / CEG

Checked Marília França / DEERNS

Project No.
RBR400.00016.00

M.S. Project No.


P.18352

Mechanical Engineering Lead

STEEL LIST - STEEL CA-50 THIAGO CAVALIERI / DEERNS


MATERIALS CONSUMPTION TABLE Plumbing Engineering Lead
LID SLAB DOUGLAS ARAUJO / DEERNS
EARTH MOVEMENT Fire Protection Engineering Lead
C.T. POSITION DIAMETER (mm) QUANT. LENGHT UNIT (m) LENGHT TOTAL (m)
DOUGLAS ARAUJO / DEERNS
BAS Engineering Lead
N1 10.0 32 1.49 47.68 MATERIALS UNIT FERNANDO SANTOS / DEERNS
EXCAVATION m3 -- Electrical Engineering Lead / EPMS
N2 10.0 48 0.57 27.36 SAMUEL FERNANDES / DEERNS
REMOVAL ( GET OUT ) m3 -- Telecommunications / Network Engineering Lead
N3 10.0 2 2.33 4.66 FUND HAPING m2 3,20 JOHN PEDRO / TEECOM
CONCRETE BRICK

SLAB
Security Engineering Lead
39 x 19 x 19 cm BACKGROUND m3 -- TAYLOR OLDHAM / TEECOM
N4 10.0 8 1.04 8.32 Civil Engineering Lead
SLABS AND LID MARÍLIA FRANÇA / DEERNS
FLOOR SLAB

VARIABLE
Structural Engineering Lead

0 to 19
MATERIALS UNIT TOTAL MARÍLIA FRANÇA / DEERNS
POSITION DIAMETER (mm) QUANT. LENGHT UNIT (m) LENGHT TOTAL (m) Architectural Lead
FORMS m2 4,15 GRAZIELLE BERANGER / DEERNS
N5 10.0 48 1.89 90.72 FRAME kg 134,21
LEAN CONCRETE BALLAST fck >= 15 MPa m3 0,16
MICROSOFT
N6 12.5 24 0.90 21.60 Design Manager
CONCRETE fck >= 30 MPa m3 0,72 CAROLINA ESPINOZA

19
FILLING (MORTAR 1:3) m3 0,16 Civil, Site Survey, Landscaping Technical Lead
SONDWIP DHAR
Structural Technical Lead
WALLS DAVID SWANSON
Architectural Technical Lead
MATERIAIS UNIT TOTAL PETE MAGOULIK / TODOR NIKOLOV
2 Ø12,5mm SUMMARY - STEEL CA-50 Mech, Plumbing & Fire Protection Technical Lead
(SEE NOTE 03) FRAME (PILAR AND STRAPS) kg/ml 46,40
STEVEN TOUPIN
STRUCTURAL CONCRETE BLOCK m2/ml 5,60 Building Automation Systems (BAS) Technical Lead
DETAIL - MANSORY LINTELS Ø (mm)
LENGHT. WEIGHT WEIGHT
CONCRETE FOR FILLING m3/ml 0,42
BILL GEMBINSKI
VIEW HDPE PIPE
TOTAL(m) UNIT.(kg) TOTAL(kg) Electrical Technical Lead
GUILHERME FERNANDES
NO SCALE COATING (MORTAR 1:3) m3//ml 0,10
10.0 178.74 0,63 112.61 Electrical Power Management Systems (EPMS) Technical Lead
-- -- --
PERSPECTIVE SERGIO FRANCO
-- -- -- Telecommunications / Network Technical Lead
NO SCALE 12.5 21.60 1,00 21.60 ALEX CARDIASMENOS
Security Design Manager
ANDREA VILLEGAS
TOTAL WEIGHT 134.21

Obs: NOT CONSIDERED QUANTITATIVE Revisions


STEELS N7 (VARIABLE)
No. Date Description
A 13 JAN 2023 50% DESIGN REVIEW
B 20 FEB 2023 100% DESIGN REVIEW
C 10 MAR 2023 ISSUE FOR PERMIT
D 31 OCT 2023 ISSUE FOR CONSTRUCTION

Registration

GENERAL
THISCONTRACTOR
RECORD DRAWING NOTE - THE
IS A LEVEL OF
DETAIL COMPILATION
INDICATED ONOFTHE PLANS IS TO CONVEY
INFORMATION
NOT FOR
THE DESIGN INTENT.
RECEIVED
IS RESPONSIBLE
CONTRACTOR(S)
DESIGN THE
DETAIL
THE GENERAL CONTRACTOR
FROM
TO PRODUCE
NECESSARY
ANY ADDITIONAL
/ SUPPLIER(S).
FOR CONSTRUCTION
INFORMATION SHOWN ON
CONSTRUCTION
INCLUDING
REQUIRED.
ADDITIONAL
THE DRAWING ENGINEERING
HAS NOT
ADDITIONAL
BEEN
ENGINEERING
VERIFIED FOR ACCURACY OR
AS
DETAILS
SHALL BE SUBMITTED TO THE ENGINEER OF
COMPLETENESS.
RECORD FOR REVIEW TO CONFIRM THAT THE
ORIGINAL DESIGN INTENT WAS MET.
159
2x2Ø12,5mm
L=VARIABLE 179 47 Ø65 47
4 N6+N7 2 N6+N7 4 N6+N7 2x6 N2 Key Plan
8
8

N.1 2x16 Ø10.0mm c/13cm C=149cm

N.2 2x24 Ø10.0mm c/13cm C=VAR.

LOCATION
N2

2x4 N1
d*

N1
47

POINT
N.5 2x24 Ø10.0mm c/15cm C=189cm

N1

N1

N7 Ø12.5mm c=Variable

N7
PLAN TRUE
N
4

d*
N

N.3 2x1 Ø10.0mm C=233cm

N.4 2x4 Ø10.0mm C=104cm


0 1 2 3
N5 VARIABLE
VAR. 8

N2
2 N6+N7

2 N6+N7

A
133

20
2x6 N2

2x6 N2

104
Ø65
159

N3 50 A COLO 1 COLO 2

40
173

N2

N6
N5

h = 15cm F
179

40
d* N
4

4
N

N1
LID F°F°
2x4 N1

Start N.6 Ø12.5mm C=90cm CONFIDENTIAL - DO NOT DISCLOSE. This


4 N6+N7

4 N6+N7

N2

PATTERN C250.
47
d*

CONCRETE document is exempt from public disclosure under the


8

fck >= 30 MPa Public Disclosure Act and Uniform Trade Secrets Act.
2x2Ø12,5mm FOUNDED ON THE SLAB
BACKGROUND OR LOWER BLOCKS h = 15cm DETAIL - REINFORCEMENT OF THE STARTER BAR
LID PLAN
8

d*= 0.15 m 2x4 N1 2x6 N2 2x4 N1


2 N6+N7 NO SCALE
TUBES OF Ø 50 e 60

INTERMEDIATE LID SLAB - REINFORCEMENT LID SLAB - REINFORCEMENT PLAN Sheet Title/Number

DETAIL OF THE TUBE FILLING IN THE BOX PRE-CAST PRE-CAST


NO SCALE
NOTE: PREDICT START FOR CHIMNEY DOWEL

DRAINAGE DETAILS
MANHOLE WITH
STEEL LID

CPQ07-C-F-04-0
MICROSOFT CONFIDENTIAL

You might also like