Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

1.1 LIGHTNING ARRESTER 1.

15 POWER PANELBOARD
PP 9. CLOCK
C C

SURGE ARRESTER
LIGHTING PANELBOARD 10. SINGLE CONVENIENCE
1.2 1.16 LP

GROUND (EARTH) MOTOR CONTROLER, 3


11. DUPLEX CONVENIENCE
1.3 1.17 POLE ACROSS-THE LINE
2

GROUND (FRAME) COMBINATION TYPE 12. WEATHERPROOF CONVENIECE


1.4 1.18 MOTOR,CONTROLLER;ATL STARTER
WP
PLUS FUSE DISCONNECT SWITCH
SERVICE ENTRANCE or
COMBINATION TYPE MOTOR,
(POWER) 2--W 3--W 1.19 13. COOKING RANGE
1.5 CONTROLLER: ATL STARTER PLUS CB
CIRCUIT BREAKER R

14. CONVENIENCE WITH SWITCH


SERVICE ENTRANCE 1.20 OUTLETS CEILING WALL
1.6
(TELEPHONE) SW

KILOWATT-HOUR METER M
1. INCANDESCENT LAMP 15. SPECIAL PURPOSE ACU
M OR WH
1.7 D

2. VAPOR DISCHARGE LAMP 16. FLOOR (P,T,I)


P
V
1.8 SAFETY SWITCH
V T
I

3. DROP CORD LAMP


DISCONNECT SWITCH 17. ANTENNA
1.9 D
ANT

4. EXIT LAMP
TRANSFER SWITCH 18. MICROPHONE
X X
1.10 MIC

5. FLOURESCENT LAMP
CIRCUIT BREAKER TELEPHONE
1.11

6. LAMP OUTLET WITH PULL SWITCH


20. INTERCOM
1.12 FUSE PS PS

7. OUTLET WITH BLANK COVER


FUSE CUTOUT B
1.13 B

8. FAN
MAIN DISTRIBUTION MDP F
1.14 F
PANEL BOARD
1.21 SWITCHES 4. FLAME DETECTOR
1.26 CIRCUIT HOMERUN 1 FD
(NUMBER INDICATES CIRCUIT NO.)
1. SINGLE POLE S 5. SMOKE DETECTOR
1.27 SD
2. DUPLEX PUSH BUTTON
(2 SINGLE POLE SWITCHES ONE SWITCH POLE) S₂
6. IONIZATION
BUZZER (INDICATE VOLTAGE)
3. TRIPLEX
(3 SINGLE POLE SWITCHES ONE SWITCH POLE)
S3 1.28 ID

WIRING SYMBOLS (CROSS LINE


4. DOUBLE POLE 1.29 BELL (INDICATE VOLTAGE)
S INDICATE NUMBER OF WIRES)
2P
1. CONDUIT
5. THREE POLE
S3P 1.30 HORN

2. OPEN WIRING
6. THREE-WAY
S3W 1.31 AMPLIFIER

7. FOUR WAY S 4W 3. UNDERGROUND


1.32 ANNUCIATOR

8. AUTOMATIC DOOR S AD
4. EMERGENCY
1.33 LOUDSPEAKER E E
9. KEY OPERATED SK
10. MASTER SELECTOR
SM 1.34 TELEPHONE EXCHANGE
TE
5. FIRE ALARM FA FA

SRC 6. TELEPHONE T T
11. REMOTE CONTROL 1.35 TELEPHONE TERMINAL CABINET TTC

7. INTERCOM
JUNCTION BOX J 1.36 FIRE ALARM SYSTEM IC IC
1.22

8. BELL SYSTEM
B B
1.23 PULL BOX PB 1. MANUAL F

RISER UP 9. TV ANTENNA TV TV
1.24 R 2. CONTROL PANEL FACP

RISER DOWN CCTV CCTV


1.25 3. HEAT DETECTOR HD 10. CLOSED CIRCUIT TELEVISION
4. BREAK CONTACT, DELAYED MAKE 6. PRESSURE ACTUATED
4.0 RELEASES

4.1 THERMAL OVERLOAD RELEASE 7. TEMPERATURE ACTUATED


or CONTACTOR WITH THERMAL OVERLOAD
5.6 RELEASES

MAGNETIC OVER CURRENT RELEASE TRIPLE-POLE CIRCUIT BREAKER WITH 8. LIQUID LEVEL ACTUATED
4.2 LATCHING MECHANISM
5.7 3P

4.3 UNDERVOLTAGE RELEASE TRIPLE-POLE LOEAD BREAKER SWITCH


UV 5.8
6.0 SWITCHBOARD
3P

OPEN-CIRCUIT SHUNT RELEASE TRIPLE-POLE FUSED ISOLATOR MAIN SWITCHBOARD


4.4 5.9 6.1
TC MSB
3P

TRIPLE-POLE ISOLATOR
5.0 SWITCHGEAR 5.10 6.2 AUXILIARY SWITCHBOARD ASB
3P

MAKE CONTACT (NO) ISOLATING LINK, CHANGE-OVER TYPE


5.1 6.3 EMERGENCY SWITCHBOARD ESB
5.11

SINGLE-THROW SWITCH, MANUALLY MOTOR CONTROL CENTER


5.2 5.12 OPEARATED 6.4 MCC
BREAK CONTACT (NC)

5.3 CHANGE-OVER SPRING-RETURN SWITCHES 7.0 VALVES (TUBES), SEMICONDUCTORS ELEMENTS


5.13

1. MANUALLY OPERATED WITH 1 ELECTRONIC VALVE, DIODE


5.4 CHANGE-OVER CONTACT MAKE BEFORE 7.1
NORMALLY OPENED CONTACT
BREAK

ELECTRONIC VALVE TRIODE


TIME-DELAYED CONTACTS 2. MANUALLY OPERATED WITH 1 7.2
5.5 NORMALLY CLOSED CONTACT

3. FOOT OPERATED SINGLE ANODE RECTIFIER VESSEL WITH


1. MAKE CONTACT, DELAYED MAKE 7.3 MERCURY CATHODE (IGNITION)

4. CAM OPERATED SEMICONDUCTOR DIODE


2. BREAK CONTACT, DELAYED BREAK 7.4

3. MAKE CONTACT, DELAYED BREAK 5. FLOW SPEED ACTUATED


7.5 LIMITING DIODE UNI-/BIDIRECTIONAL OR OR
11. MUSIC M M DC GENERATOR DC SERIES-WOUND MOTOR, INTERPOLE
2.2 G 2.16
WINDINGS ARRANGED IN SYMMETRY M
WITH THE ARMATURE
12. CLOCK C C
DC GENERATOR WITH PERMANENT
AC MOTOR M M
2.3 ~ 2.17 MAGNET EXCITATION

1.38 BATTERY DC MOTOR THREE PHASE COMMUTATOR MOTOR


M WITH SHUNT CHARACTERISTICS, M

2.4 2.18 3~

ROTOR FED

1.39 RESISTOR THREE-PHASE COMMUTATOR MOTOR


UNIVERSAL MOTOR M
~ 2.19 WITH SERIES CHARACTERISTIC
2.5 M
3~

1.40 INDUCTOR CHANGE POLE SQUIRREL-CAGE


MOTOR-GENERATOR M G
2.6 2.20 INDUCTION MOTOR FOR CHARGING 8/4P~
FROM 8-4 POLES M

CHANGE POLE SQUIRREL-CAGE


1.41 CAPACITOR THREE PHASE INDUCTION MOTOR WITH
3 4 3

M
INDUCTION MOTOR WITH TWO SEPARATE
2.7 SLIPRING ROTOR 3~
2.21 WINDINGS FOR CHANGING FROM 8-4
M
3~
8/4P +6P

POLES AND 6 POLES RESPECTIVELY

1.42 THERMOCOUPLE THREE PHASE INDUCTION MOTOR WITH


SQUIRREL-CAGE ROTOR
M 3.0 TRANSFORMERS AND REACTORS
2.8 Δ

1.43 THREE PHASE INDUCTION MOTOR WITH TRANSFORMERS WITH TWO SEPARATE
CONVERTER, TRANSMITTER 2.9 SQUIRREL-CAGE ROTOR, BOTH ENDS OF M
3.1
3~
WINDINGS
THE WINDING BROUGHT OUT
SINGLE PHASE INDUCTION MOTOR WITH
1.44 SINGLE-PHASE BRIDGE RECTIFIER SQUIRREL-CAGE ROTOR M
2.10 1~ TRANSFORMERS WITH THREE
3.2 SEPARATE WINDINGS
THREE PHASE SYNCHRONOUS
1.45 PLUG AND SOCKET DEVICE 2.11 GENERATOR, STAR CONNECTED, GS
Δ AUTO-TRANSFORMER
NEUTRAL NOT BROUGHT OUT 3.3
THREE PHASE SYNCHRONOUS
FILAMENT LAMP 2.12 GENERATOR, STAR CONNECTED,
1.46 GS
Δ
NEUTRAL BROUGHT OUT REACTOR
3.4
THREE PHASE SYNCHRONOUS GS
1.47 DISCHARGE LAMP 2.13 GENERATOR WITH PERMANENT 3~

MAGNET EXCITATION CURRENT TRANSFORMER


3.5
SINGLE PHASE SYNCHRONOUS GS
1~
GENERATOR WITH PERMANENT
2.0 ROTATING MACHINE 2.14
MAGNET EXCITATION
VOLTAGE (POTENTIAL) TRANSFORMER
DC SHUNT WOUND GENERATOR G 3.6
2.1 AC GENERATOR G INTERPOLE WINDINGS ARRANGED IN
~

~ 2.15
SYMMETRY WITH THE ARMATURE
4. BREAK CONTACT, DELAYED MAKE 6. PRESSURE ACTUATED
4.0 RELEASES

4.1 THERMAL OVERLOAD RELEASE 7. TEMPERATURE ACTUATED


or CONTACTOR WITH THERMAL OVERLOAD
5.6 RELEASES

MAGNETIC OVER CURRENT RELEASE TRIPLE-POLE CIRCUIT BREAKER WITH 8. LIQUID LEVEL ACTUATED
4.2 LATCHING MECHANISM
5.7 3P

4.3 UNDERVOLTAGE RELEASE TRIPLE-POLE LOEAD BREAKER SWITCH


UV 5.8
6.0 SWITCHBOARD
3P

OPEN-CIRCUIT SHUNT RELEASE TRIPLE-POLE FUSED ISOLATOR MAIN SWITCHBOARD


4.4 5.9 6.1
TC MSB
3P

TRIPLE-POLE ISOLATOR
5.0 SWITCHGEAR 5.10 6.2 AUXILIARY SWITCHBOARD ASB
3P

MAKE CONTACT (NO) ISOLATING LINK, CHANGE-OVER TYPE


5.1 6.3 EMERGENCY SWITCHBOARD ESB
5.11

SINGLE-THROW SWITCH, MANUALLY MOTOR CONTROL CENTER


5.2 5.12 OPEARATED 6.4 MCC
BREAK CONTACT (NC)

5.3 CHANGE-OVER SPRING-RETURN SWITCHES 7.0 VALVES (TUBES), SEMICONDUCTORS ELEMENTS


5.13

1. MANUALLY OPERATED WITH 1 ELECTRONIC VALVE, DIODE


5.4 CHANGE-OVER CONTACT MAKE BEFORE 7.1
NORMALLY OPENED CONTACT
BREAK

ELECTRONIC VALVE TRIODE


TIME-DELAYED CONTACTS 2. MANUALLY OPERATED WITH 1 7.2
5.5 NORMALLY CLOSED CONTACT

3. FOOT OPERATED SINGLE ANODE RECTIFIER VESSEL WITH


1. MAKE CONTACT, DELAYED MAKE 7.3 MERCURY CATHODE (IGNITION)

4. CAM OPERATED SEMICONDUCTOR DIODE


2. BREAK CONTACT, DELAYED BREAK 7.4

3. MAKE CONTACT, DELAYED BREAK 5. FLOW SPEED ACTUATED


7.5 LIMITING DIODE UNI-/BIDIRECTIONAL OR OR
9.16 NEGATING OUTPUT

9.17 INPUT WITH POLARITY INDICATOR

9.18 OUTPUT WITH POLARITY INDICATOR

9.19 STATIC INPUT

9.20 DYNAMIC UNPUT

9.21 NEGATED DYNAMIC INPUT

9.22 INHIBITING INPUT

9.23 NEGATED INHIBITING INPUT

X
9.24 INPUT NOT CARRYING LOGIC
INFORMATION

9.25 OUTPUT NOT CARRYING LOGIC X

INFORMTION

EXTENSION INPUT E
9.26