Manufacturer:
Trademarks
Company or product names used in this manual are trademarks or registered trademarks. The indications ©, ®, and ™
shall be omitted henceforth.
Cautions
1. Unauthorized reproduction of any part of this manual is prohibited.
2. The contents of this manual may be changed without notice.
3. Any discrepancies, errors, or omissions noted should be communicated to the manufacturer.
4. Notwithstanding item 3 above, the manufacturer accepts no responsibility whatsoever for any loss or decrease in
profits arising from usage of the product.
Cautions on Disposal
When disposing of the DRYPRO 832 main unit (including lithium button battery), accessories, options,
consumables, and media, contact a licensed industrial waste treatment company to dispose of the device.
Moreover, ensure that all local by-laws and regulations prescribed by the local government are followed when
disposing of the device.
Table of Contents
Table of Contents
Foreword
1 System Overview .........................................................................1
1.1 Features of DRYPRO 832 ........................................................ 1
1.2 Main Specifications................................................................... 2
1.3 Outside Dimension ................................................................... 4
1.4 Names and Functions of Parts ................................................. 6
2 Installation Overview ..................................................................12
2.1 Installation Conditions............................................................. 12
2.2 Example of Installation............................................................ 14
3 Connections Overview ...............................................................15
3.1 Diagram of Connections ......................................................... 15
3.2 Cable list................................................................................. 17
DRYPRO 832 PRE-INSTALLATION GUIDE
1 System Overview
Image Quality
• Provides high quality and stable images with pixels size of 78.6 μm.
• Supports 12-bit image input.
• High quality rendering of various images using advanced image interpolation processing technology.
• Inclusion of the automatic densitometry management function for producing stable finished images.
Operating Environment
• Reduced output waiting time with high speed processing capacity (fast printing at 50 seconds or less)
• Additional supply tray (Lispl-832) can be installed.
• Compact size
Imaging Environment
DRYPRO 832 ensures future extensibility through open network by providing connection to the diagnostic system
equipped with the communication function over DICOM via imager server Printlink5-IN.
1
DRYPRO 832 PRE-INSTALLATION GUIDE
14 × 17 in.
14 × 14 in.
Film Size 11 × 14 in.
10 × 12 in.
8 × 10 in.
Input Interface Ethernet 10BASE-T/100BASE-TX/1000BASE-T
Protocol DICOM Print Management
Main Memory 128 MB Standard
Image Memory Print memory 64MB
When continuously printing 14 × 17-inch size sheets: Approximately 90 sheets/hour
When continuously printing 14 × 14-inch size sheets: Approximately 90 sheets/hour
Processing Capacity When continuously printing 11 × 14-inch size sheets: Approximately 90 sheets/hour
When continuously printing 10 × 12-inch size sheets: Approximately 90 sheets/hour
When continuously printing 8 × 10-inch size sheets: Approximately 90 sheets/hour
599 W × 570 H × 585mm L (without Lispl-832)
Outside Dimension
599 W × 722 H × 585mm L (with Lispl-832)
2
DRYPRO 832 PRE-INSTALLATION GUIDE
CE:
EN60601-1:1990+A1:1993+AZ1995-A13:1996 EN60601-1-2:2001,
Applicable Standards EN60601-1-4:1996-A1:1999 IEC60825-1+A2:2001
UL:
UL60601-1:2003
DRYPRO 832 is manufactured in factories certified to meet the
Remarks requirements of ISO9001:2000, ISO13485: 2003, and EN ISO9001: 2000,
EN ISO13485: 2003 quality control standards.
Power cable, two cutters, warranty, operation manual, accessories list,
deodorant filter, attached documents for doctors, inspection cards, two
clamps, film size label, operation sheet, operation sheet box, two ducts,
Accessories shutter, intermediate plate for 10 x 12 in.-size papers, intermediate plate
for 8 x 10 in.-size papers, two film regulation pins, two hexagon socket
head screws (M3 x 10 mm), Allen wrench, and two stopper covers, four
tapping screws (M3 x 8 mm), and CD-ROM
Lispl-832 (2 × hitch plates, shutter, intermediate plate for 10 × 12 inch-size
papers, intermediate plate for 8 × 10 inch-size papers, 2 × film regulation
Accessories sold
pins, 2 × hexagon socket head screws (M3 × 10mm), Allen wrench, 8 ×
separately
truss screws (M4 × 8mm), and elevating transportation unit set
attachment)
These specifications are subject to change without notice due to continual improvements.
3
DRYPRO 832 PRE-INSTALLATION GUIDE
392
570
517
197
16 585 9
610 51
599
722
669
449
4
DRYPRO 832 PRE-INSTALLATION GUIDE
When the exhaust duct is installed When the front cover is open
599
634
268
15
555
180
5
DRYPRO 832 PRE-INSTALLATION GUIDE
8. Air intake
6
DRYPRO 832 PRE-INSTALLATION GUIDE
5. Air intake
7. LAN cover
2. Exhaust duct
7
DRYPRO 832 PRE-INSTALLATION GUIDE
Operation panel
1. Message display window
8
DRYPRO 832 PRE-INSTALLATION GUIDE
2. Lever B
1. Lever A
9
DRYPRO 832 PRE-INSTALLATION GUIDE
3. Ethernet port
2. Air intake
• To remove the LAN cover, lift it while raising lower tabs (two locations) of the LAN cover straight.
• To install the LAN cover, first insert the upper tabs (two locations) of the LAN cover and then the lower tabs
(two locations).
10
DRYPRO 832 PRE-INSTALLATION GUIDE
Supply Tray
2. Film regulation pin
mounting hole (14 x 14 in.)
3. Partition
plate
Lispl-832 (Option)
1. Lispl-832
11
DRYPRO 832 PRE-INSTALLATION GUIDE
2 Installation Overview
Installation location
Check that the installation location meets the following requirements.
• Place where the machine is not exposed to water.
• Place where air pressure, temperature, humidity, ventilation, sunlight, dust, salinity, inflammable gas or air
containing sulphur does not adversely affect the machine.
• Place where the machine is not subject to inclination, vibration or shock (including during transportation).
• Place where chemicals are not stored.
• Place where gas is not emitted.
• Place where odors emitted from DRYPRO 832 can be ventilated.
• Place located not near the noise source.
• Place where a passer-by is not likely to trip over the power cable or ethernet cable accidentally when it is
routed.
• Place where air intakes and outlets on the side or back of the machine are not blocked.
Installation Space
Check the place where installation space as shown below can be secured.
100mm (4inch)
or more
500mm (20inch) 500mm (20inch)
or more or more
1000mm (40inch)
or more
Maintenance Space
Check that the maintenance space as shown below can be secured in the installation location.
800mm (32inch)
or more
1000mm (40inch)
or more
12
DRYPRO 832 PRE-INSTALLATION GUIDE
Power Conditions
Check that the wall outlet that meets the following requirements is provided in the installation location.
• Voltage: CE:AC 220-240V±10%
UL:AC 120V±10%
• Frequency: 50Hz or 60Hz
• Maximum consumption current: CE:6A UL:10A
• Ground: Class D
Unpacking Area
Check that the unpacking area meets the following requirements.
• Flat area where there are no objects that will interfere with unpacking.
Transfer Path
Check that the transfer path from the unpacking area to the installation location meets the following requirements.
• There are no obstructions such as steps or steep slopes that the DRYPRO could collide with during transfer.
• The doorway of the room through which DRYPRO 832 passes should be sufficiently large.
• No deformation should be detected on the floor surface even after transporting DRYPRO 832 (weight:
approximately 88kg (without Lispl-832)/approximately 110kg (with Lispl-832)).
13
DRYPRO 832 PRE-INSTALLATION GUIDE
Use a category 5E or higher LAN cable to connect between the DRYPRO 832 ~ Network Hub ~
Printlink5-IN. If a LAN cable lower than a category 5E is used, fast printing at 50 seconds
Important cannot be guaranteed.
Ethernet Hub
LAN cable
Ethernet Hub
LAN cable
14
DRYPRO 832 PRE-INSTALLATION GUIDE
3 Connections Overview
Use a category 5E or higher LAN cable to connect between the DRYPRO 832 ~ Network Hub ~
Printlink5-IN. If a LAN cable lower than a category 5E is used, fast printing at 50 seconds
Important cannot be guaranteed.
Network hub
Power supply
Printlink5-IN
15
DRYPRO 832 PRE-INSTALLATION GUIDE
LAN cable
Serial cable
(InterfaceKit:C*)
Power supply
Network hub
UPS
(Smart UPS 2200*)
Power supply
Printlink5-IN
*: Smart UPS 2200 and InterfaceKit:C are product codes recommended by the manufacturer.
Caution
16
DRYPRO 832 PRE-INSTALLATION GUIDE
Network hub
When using UPS
LAN cable
Serial cable
(InterfaceKit:C*)
*: Smart UPS 2200 and InterfaceKit:C are product codes recommended by the manufacturer.
Use a category 5E or higher LAN cable to connect between the DRYPRO 832 ~ Network Hub ~
Printlink5-IN. If a LAN cable lower than a category 5E is used, fast printing at 50 seconds
Important cannot be guaranteed.
17
Konica Minolta Medical Imaging U.S.A., Inc. Konica Minolta Business Solutions
411 Newark Pompton Turnpike, Wayne, NJ 07470, U.S.A. (Canada) Ltd.
TEL. 973-633-1500 369 Britannia Road East, Mississauga,
Ontario, L4Z 2H5, Canada
TEL. 905-890-6600
0921YH220B
070627YM