HB-D1817-AR-131 - Typical Unit Plan of 3room Type With Tiling Layout

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

ARCHITECTURAL

300 400 1800 600 300 600 1800 300300 475 2400 525 300 525 2400 475 300300 1800 600 300 600 1800 400 300 TENDER
CFW
150 150
CFW
2
AMENDMENT
alum framed with tinted glass
casement window CFW
2

CFW
2
NO. 5 DRAWING
2 CFW
1

150
2 nos. ss anchor for 2800
CFW
1 hanging flag
CONSTRUCTION

150

1650
1500 2900
DRAWINGS

3000

3000
BEDROOM BEDROOM

2900 3000
vinyl strip flooring
with laminate UPVC MAIN MAIN
skirting
3700

3700
BEDROOM BEDROOM

DM
5
DM
TYPE 3R-1 TYPE 3R-1 TYPE 3R-1 5
gable end wall LIVING / DINING .LIVING / DINING LIVING / DINING
2200

2200
full-piece uncut threshold
tile to match wall tile

DM

DM
5

5
1500 polished porcelain tiles 1800 2045

190(W) x 110(H) UPVC rectangular 100mm thk wall

20

20
pipe sleeve (to engr's drawing) BFD BFD BFD
20

20
2 BFD 1 2
ventilation sleeve and fragmentation

1000

1000
1
sanitary wares and fittings 1500
1000 DRY KITCHEN plate to detail DRY KITCHEN 1000
to refer to specifications
1950

1710

1710

1950
1250 1250 FT D 03-2022 TENDER AMENDMENT 5 CC
FT BATH / WC 1
BATH / WC 2 BATH / WC 2
BATH / WC 1 C 02-2022 TENDER AMENDMENT 4 CC
alum casement glazed porcelain tiles B 02-2022 TENDER AMENDMENT 3 CC

1500

1500
DRY KITCHEN
window with lockset HOUSEHOLD HOUSEHOLD HOUSEHOLD A 01-2022 TENDER CORRIGENDUM 2 CC
.

BD

BD
FW FW FT FT

1
TH CW
TH SHELTER SHELTER SHELTER
2
FW FW 11 REV DATE SUBJECT CHKD
2
450 service closet to detail FDM
190(W) x 110(H) UPVC rectangular FDM 1 REVISION NOTES
pipe sleeve (to engr's drawing) CW
1
tile termination line
11
1000

1000
NOTE :
G.S railing to detail ramp to be provided with structural tiles 1. Architectural dimension & levels are based on finished floor level.
AC LEDGE KITCHEN /
(ramp not more than 50mm) KITCHEN / AC LEDGE 2. Contractor to make allowance for Structural & Architectural levels & dimensions.
CW

CW
12

12
UTILITY UTILITY
3. Shop drawings to be provided for Architect's approval.
1500

1500
fixed stainless steel external 4. All dimensions to be verified and discrepancies shall be reported to the Architect immediately.
450 450 5. Main Contractor to comply with PE requirements for all glass under their own cost.

G&W

G&W
clothes drying deck

1500

1500
1 / 2 HR fire rated decorative door
950

950
and metal gate FT TENDER: D 1817
internal ceiling mounted FT
1250 . HR/WR .
HR/WR 1250
retractable clothes drying DC SUBMISSION: HB-DL-D1817
rack . E
15°

300

300
2375 600 3425 400 1250 150 1900 1900 150 1250 3825 600 2375 KALLANG WHAMPOA C36

OWNER
3 ROOM TYPE 1 3 ROOM TYPE 1 (HANDED) HOUSING &
DEVELOPMENT
SCALE 1: 50 SCALE 1: 50 BOARD

HDB HUB 480 LORONG 6 TOA PAYOH SINGAPORE 310480


525 2400 475 600 1800 600 300 600 1800 400 300
150
CFW
PROJECT

2 nos. ss anchor for


2
KALLANG WHAMPOA CONTRACT

150 500
hanging flag CFW
2
36 - PROPOSED PUBLIC HOUSING

1200
DEVELOPMENT COMPRISING A
CFW BLOCK OF 33/47 STOREY
1
3000 2900
RESIDENTIAL BUILDING WITH SKY

150

1500
BEDROOM 2
TERRACE AT 22ND AND 34TH

3000
vinyl strip flooring
with laminate UPVC STOREY [TOTAL 398 UNITS], 1
alum frame with tinted glass skirting
casement window MAIN
BLOCK OF MULTI-STOREY

3700
BEDROOM CARPARK WITH ROOF TERRACE &
polished porcelain tiles TYPE 3R-1 DM
ESS AND A PAVILION ON LOTS
5
LIVING / DINING
2181C PT, 98934X PT, 2853P PT,

3700

2200
gable end wall
ventilation sleeve and 2852V PT, 2278N PT, 98933N PT,
fragmentation plate to detail 98936C PT, 2176X PT, 1517W PT,

DM
5
1500 95 1800 130 2045
707W PT, 2632A PT, 706M, 704L,
BFD BFD
full-piece uncut threshold
1 2
705C TS 17 AT KING GEORGE’S

120
1 / 2 HR fire rated decorative timber tile to match wall tile

20

20
door and metal gate 190(W) x 110(H) UPVC AVENUE / SYED ALWI ROAD
rectangular sleeve (to engr's
DRY drawing) (KALLANG PLANNING AREA)
tile termination line

1710
1250 KITCHEN BATH / WC 2 BATH / WC 1 FT
sanitary wares and fittings
to refer to specifications

1500
BD

2950
glazed porcelain tiles

1
FT TH FW FW alum casement window with
HOUSEHOLD lockset
2
LOT NO.: TS NO.:

2300

120
service closet to detail SHELTER
FDM
1 CW 190(W) x 110(H) UPVC 2181C PT, 98934X PT, 2853P PT, 17
11
rectangular sleeve (to engr's 2852V PT, 2278N PT, 98933N PT,
LEGEND: ramp to be provided with AC LEDGE
drawing) 98936C PT, 2176X PT, 1517W PT,
structural tiles (ramp not 707W PT, 2632A PT, 706M, 704L,

CW
12
fixed stainless steel external

1500
1950
more than 50mm) clothes drying deck 705C
450

G&W
1500
VINYL STRIP FLOORING KITCHEN
/ UTILITY G.S railing to detail

1250
FT
1250 internal ceiling mounted
retractable clothes drying rack DRAWING TITLE
POLISHED PORCELAIN TILES
TYPICAL UNIT PLAN OF 3 ROOM TYPE
300 1600 150 1250 0400 300 3125 600 2375 WITH TILING LAYOUT

GLAZED PORCELAIN TILES


ARCHITECT'S ADDRESS

3 ROOM TYPE 2 ARCHITECTURE

JGP ARCHITECTURE (S) PTE LTD 16 UPPER CIRCULAR ROAD SINGAPORE 058414
SCALE 1: 50 TEL : 63399000 FAX : 63395005 EMAIL : SIN@JGP-GROUP.COM HTTP://WWW.JGP-GROUP.COM

DRAWN CHECKED APPROVED


BY BY BY
GAB CC PC
NOTE : Note:
SCALE 1 : 50 DATE MAR 2022
Optional Component Scheme For Provision Of Internal Doors, Sanitary Fittings, Floor Finishes To Living Rooms And Bedrooms is applicable to this BTO development.
1. THE CONTRACTOR MUST CHECK ALL DIMENSIONS ON SITE. ANY DISCREPANCIES IN THE
FIGURED DIMENSIONS ARE TO BE REPORTED IMMEDIATELY TO THE ARCHITECT OR DWG NO. HB-D1817-AR- 131
ENGINEER. DO NOT SCALE-OFF MEASUREMENT FROM DRAWINGS.
REV NO. D
2. WHILE EVERY CARE HAS BEEN EXERCISED IN HIGHLIGHTING THE AMENDMENTS VIA
"CLOUDING", CONSULTANTS DOES NOT WARRANT THE ACCURANCY AND COMPLETENESS G:\JG17A448 (Kallang Whampoa C36)\
OF SUCH HIGHLIGHTING. FILENAME CD\0-Tender\MAIN\100 SERIES
JOB NO. JG17A448
3. THE CONTRACTOR SHALL VERIFY AND SATISFY HIMSELF THAT THE LATEST AMENDMENTS
ARE USED FOR CONSTRUCTION IN ACCORDANCE TO THE LATEST DRAWINGS. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE. ANY DISCREPANCIES TO BE
4. THIS DRAWING SHALL NOT BE USED OTHER THAN FOR ITS INTENDED PRUPOSE AS REPORTED TO THE ARCHITECT IMMEDIATELY. THIS DRAWING IS TO BE READ IN
CONJUNCTION WITH STRUCTURAL DRAWINGS. THIS DRAWING IS COPYRIGHT.
STATED HEREIN.