National Plumbing Code of The Philippines
National Plumbing Code of The Philippines
OF THE
PHILIPPINES
GROUP MEMBERS:
AMOREN, KRISTIANA ISABEL
ECONAR, ANGEL ANNA REY
HEREDIA, ATHEA
LAGUNA, CARLO RUEZLI
OGAO-OGAO, MARY CLAED
ORDIENESA, JODEL
PITOGO, JANINE
LEOPARDAS, JOYLYN
CHAPTER 1
ADMINISTRATION
1. Application for Permit:
4. Connection Approval:
2. Materials – Alternative
6. Shower Stall
In air testing, after closing all other inlets & outlets, air is forced in the pipe system (through a
connection with an air compressor), until there is a uniform gauge pressure of 34.5 Kpa sufficient
to balance a column of mercury 254mm in height for a period of at least 15 minutes.
In water piping, it shall be tested & proved tight under water pressure not less than the working
pressure which is to be used plus 50% for a period of at least 15 minutes. A 344.5 Kpa air
pressure may be substituted for the water test.
CHAPTER 6
WATER SUPPLY & DISTRIBUTION
1. Backflow Prevention Devices,
Assemblies, & Methods
5. Valves
2. General Requirements
3. Specific Requirements
4. Material
8. Installation, inspection, & Testing
11. Support
Drainage Fittings
4. Cleanouts
5. Drainage of Fixtures Location Below the Upstream Manhole or Below the Main
Sewer Level
Discharged pipe not be less than Vent of sump & Receiving tanks shall extends
50.8 mm diameter separately to the roof by 51 mm min.
3. Vent Termination
2. Trap Seals
Accessible for cleaning & shall have a water seal not less than 152mm deep
4. Grease Traps
Total capacity shall not exceed 2 ½ times the certified liters per minute flowrate
of grease traps
5. Sand Interceptors
Shall have a dimension of 0.2m^2 min. for the net free opening of the inlet
section & a 610mm min. depth under the invert of the outlet pipe
CHAPTER 11
STORM DRAINAGE SYSTEM
1. Rainwater system
2. Roof Drain
Strainers
Vertical Wall Areas
For 1 wall – add 50% of area of the wall to the roof area
For 2 adjacent walls – add 35% of the total wall areas to the roof area
For 2 walls opposite each other & of the same heights – add NO additional area
Vertical piping may be round, square or rectangular provided that the area of a
rectangular piping shall have at least the equivalent cross sectional area of a circular
piping & its dimensions shall not exceed 3 to 1.
CHAPTER 12
HOUE DRAIN & HOUSE SEWERS
1. Sewer Required
Public sewer is not available located more than 61m from the proposed building
or exterior facility.
Grade of building sewer shall not be less than 2%. Not be installed not less than
0.6m, and nor less than 0.3m below the finish surface of the ground.
4. Cleanouts
Sewer cleanouts shall be installed not to exceed 15m o.c in straight runs & each
aggregate exceeding 135 degrees.
Bottom of the water pipe shall be at least 0.3m above the top of the sewer or drain line.
Shall be plugged or capped in an approved manner within 1.5m of the property line.
CHAPTER 13
JOINTS & CONNECTION
1. Types of Joints
Threaded Joints
Caulked Joint
z
Wiped Joints
2. Use of Joints
Slip Joints
Expansion Joints
2. Lead
1. General
Velocities shall not exceed 3m/sec of the maximum values given in the
appropriate installation standard.
Allowances in Equivalent Length of Pipe shall be based on non-recessed
threaded fittings. For recessed threaded fittings or streamline solder fittings,
use 1/2 the allowances.
1. General
7. Disposal Fields
8. Seepage Pits