Intl J of Energy Research - 2021 - Cascetta - Thermocline Vs Two Tank Direct Thermal Storage System For Concentrating
Intl J of Energy Research - 2021 - Cascetta - Thermocline Vs Two Tank Direct Thermal Storage System For Concentrating
DOI: 10.1002/er.7005
RESEARCH ARTICLE
1
Department of Mechanical, Chemical
and Materials Engineering, University of
Summary
Cagliari, Cagliari, Italy This paper concerns the ongoing studies on a Concentrated Solar Power (CSP)
2
Department of Mechanical Engineering, plant in operation in Ottana (Italy), comprising a 629 kW organic Rankine
Federal University of Petroleum
cycle (ORC) unit fed by a linear Fresnel solar field. Hexamethyldisiloxane
Resources, Effurun, Nigeria
(MM) and “Therminol SP-I” are used respectively as ORC working fluid and
Correspondence heat transfer fluid in the solar receivers. A two-tank direct Thermal Energy
Mario Petrollese, Department of
Mechanical, Chemical and Materials
Storage (TES) system is currently integrated in the CSP plant, serving as a
Engineering, University of Cagliari, Via direct interface between solar field and ORC. With the view of improving the
Marengo, 2, Cagliari, Sardegna 09123, solar facility, two alternative TES configurations were proposed in this study: a
Italy.
Email: petrollese@unica.it
one-tank packed-bed TES system using silica as solid storage media and
another similar one including encapsulated phase-change material (molten
salt). Comprehensive mathematical models were developed for simulating
daily behaviour as well as for assessing yearly performance of the various TES
technologies. Furthermore, a preliminary economic analysis was carried out.
Results showed poorer response of the one-tank TES system to large fluctua-
tions in the ORC inlet fluid temperature, leading to reduction in the mean
ORC efficiency (18.2% as against 19.7% obtained with the two-tank TES). Con-
versely, higher energy storage density and lower thermal losses were obtained
adopting the one-tank TES, resulting in about 5% more annual solar energy
yield. Invariably, equivalent annual ORC energy production of 0.92 GWh/year
was obtained for the three TES configurations. Additionally, adopting a one-
tank TES system meant that the purchase costs of a second tank and its storage
medium (thermal oil) could be saved, resulting in investment costs about 45%
lower and, ultimately, levelized cost of storage about 48% lower than what
obtains in the two-tank TES system.
KEYWORDS
concentrating solar power, packed-bed, phase change materials, TES system, thermal
storage medium
This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided
the original work is properly cited.
© 2021 The Authors. International Journal of Energy Research published by John Wiley & Sons Ltd.
the thermal behaviour after multiple charge/discharge than what obtains with the solid-filler material. Similarly,
cycles is independent of most operating parameters and Zanganeh et al35 presented a multi-layered TES system
depends mainly on the thermocline control strategy. for CSP applications featuring a single thin PCM layer
Rodat et al29 developed a dynamic model of a CSP plant with elevated melting point positioned at the top of a
composed by a Fresnel solar field with oil as HTF, an packed bed of rocks. The simulations showed that stabil-
organic Rankine cycle (ORC) unit, and a dual-media ity would be sufficiently achieved for the outflow air tem-
thermocline TES system. The numerical results con- perature close to the melting point of the PCM, with
firmed the robustness of the overall solar plant also in PCM quantity measuring only about 1.33% of the total
possible critical situations if reliable control strategies are storage volume, without any negative effect on the over-
implemented for the TES system. A validation of these all efficiency.
results is given by experimental tests made on a 30 m3 All the above-cited studies clearly show that the
cylindrical tank equipped with thermocouples for tem- choice of the most appropriate TES technology for practi-
perature measurements at the inlet, the outlet, and the cal applications remains daunting for designers and prac-
middle sections of the bed.30 Chacartegui et al31 investi- titioners, due basically to the high dynamical tendencies
gated the expected performance of an ORC plant coupled during operations. In particular, different storage mate-
with a 5 MW CSP plant of parabolic trough type and inte- rials often possess different heat transfer characteristics,
grated with two different thermal storage types: a direct which could usually be enhanced depending on operat-
TES system using molten salt as both HTF and storage ing temperature range, thermal inertia, and HTF flow
medium and an indirect one using diathermic oil as HTF control; all of which correlate with the overall cost of
and molten salt as storage medium. Results showed a TES systems. A research gap in this field remains the
similar efficiency of the power block comparing the two technical and economic evaluation of different TES types
TES systems, but the direct TES system requires a tank in real CSP plants with known operational features. The
volume reduced by 26% compared to the indirect TES. results of such comparative studies, if carried out com-
Moreover, techno-economic analyses were also presented prehensively enough, would serve as viable sources of
in literature to demonstrate the profitability of thermo- information for designers, policymakers, and other stake-
cline TES configurations. A numerical comparison holders, in the design/selection of appropriate TES tech-
between two-tank and thermocline storage systems was nologies for future CSP projects.
carried out in Rodríguez et al32 to evaluate the best sys- In order to contribute substantially to the research
tem to integrate with a CSP-ORC system. The results rev- gap identified in the foregoing, this study is aimed at
ealed the superior global attractiveness of the comparative techno-economic assessment of different
thermocline solutions, since they exhibited similar ther- TES technologies prominent for application in medium-
mal performance but at a much lower cost of about 30%. scale CSP systems, with reference to a real 629 kW CSP-
The relative cost reduction of TES systems based on ther- ORC plant running at Ottana, Italy. The plant integrates
mocline configurations was also proven by Pacheco an active direct two-tank TES system using thermal oil as
et al,13 based on the experimental results carried out on a storage medium. Currently, research activities are under-
small pilot-scale (2.3 MWh) thermocline indirect storage way to investigate practical solutions for improving the
system using molten salt as HTF. entire facility, of which structural optimization of
Recently, innovative thermocline TES configurations the installed TES technology is vital. Thus, other similar
based on a combination of solid media and PCM were TES technologies are being considered that could provide
proposed in literature for enhancing the thermal perfor- better alternatives to the existing one. Specifically, the
mance and thermal stability of these storage devices. On technical and economic performance of two other TES
this subject, a new concept of thermocline-like TES configurations, a one-tank thermocline packed-bed sys-
device called multi-layered solid-PCM (MLSPCM) was tem with rock and sand as storage media and a similar
presented in Galione et al.33 Practically, the middle one that incorporates PCM in form of capsules, are fur-
section of a packed bed is filled with cheap solid particles, ther investigated in comparison with the two-tank TES
while the top and bottom of the packed bed are respec- currently in operation. One of the most important issues
tively occupied by two types of encapsulated PCM close addressed in this study is the interaction between the
in phase change temperatures to the operating tempera- new proposed TES system with the solar field and
ture limits.34 In this case, effects of thermal buffering on the ORC plant currently installed. Adopting the two-tank
PCM layers gave rise to only minor degradation of the system, both solar and ORC plants always work in a quite
thermocline in the entire charging cycle. Moreover, stable condition, since both the cold oil entering the solar
reducing the volume of the encapsulated PCM resulted in field and the hot oil entering the ORC plant keep gener-
very similar storage quality, albeit at much higher costs ally an almost constant temperature, therefore the
17724 CASCETTA ET AL.
circulating mass flow rate in the solar field is regulated conditions, the storage system can store about 15 MWh
only according to the DNI to keep constant the outlet of thermal energy, accumulating around 195 tons of ther-
temperature. Conversely, using the thermocline TES sys- mal oil (“Therminol SP-I”). The latter flows through the
tem, the solar field is expected to receive oil at increasing solar field as HTF and serves equally as storage medium
temperature, particularly when the TES system is near in TES tanks. The solar field is designed for a total col-
the end of the charge phase. In this case, the mass flow lecting area of about 8400 m2, composed specifically of
rate needs to be increased to meet the requested oil tem- six parallel lines of linear Fresnel collectors with tracking
perature at the exit. In addition, the ORC plant is mechanism along North-South direction. The HTF circu-
expected to receive oil at lowering temperature from the lating through the solar field is designed for a mass flow
TES system during the discharge phase. Ultimately, both rate of 18 kg/s and a temperature difference of 110 C
the solar field and the ORC plant are expected to work between outlet and inlet collector sides. The control sys-
partially in off-design conditions and this aspect is care- tem is set to regulate HTF mass flow rate as solar irradia-
fully investigated in this work, since it affects the global tion fluctuates, to maintain as constant the HTF nominal
efficiency of the plant. Moreover, the current ORC plant temperature at solar collector exit. At power generation
is one of the largest in size integrated with a CSP phase, the thermal oil stored in the TES hot tank is
plant and a TES system completely operating at the pumped to the power block, where its energy content
moment, making this study more attractive. A dynamic is exploited as it flows through the interfacing heat
simulation is a credible choice to reproduce the behav- exchangers, after which it is pumped back to the TES
iour of the overall plant as close as possible to the reality, cold tank. An ORC unit (“Turboden 6HR Special”) based
also evidencing the effects on performances by adding a on regenerative Rankine cycle running with organic
layer of PCM at the top of the bed of the TES system. As working fluid (hexamethyldisiloxane, C6H18OSi2). is used
aforementioned, findings from such comparative study for thermal-to-electricity thermodynamic conversion
would be directly applicable to other medium-scale CSP process.
systems, thereby providing a general scientific contribu-
tion that would be useful to designers, researchers as well
as energy policymakers. The study is particularly vital, 2.2 | Alternative TES configurations
given that one of the compared TES configurations, the
thermocline TES configuration that combines solid mate- In this work, the actual two-tank TES system is compared
rial with PCM as storage media, is relatively new, and with two alternative TES configurations. A one-tank ther-
thus requires more investigations regarding its practical mocline packed-bed system using rock and sand as
performance in real power plants as is the case here. thermal storage media is assessed vis-a-vis another simi-
The specific objectives of this paper are: lar but with the upper layer composed of capsules filled
with PCM and sand in the interstices between the cap-
• Detailed thermodynamic modelling of the three TES sules. The adoption of PCM placed at the top of the tank
systems as well as the CSP and ORC units. is aimed at keeping as stable as possible the temperature
• In-depth analyses of daily control management strate- of the oil supplied to the ORC unit for improving the per-
gies of the different TES technologies for integration formance of the overall system.35 In both cases, a reser-
with the CSP and ORC units. voir with the same dimensions of the hot tank present at
• Comparative annual energy performance of the plant the facility is adopted, consisting in a cylindrical steel
with respect to the different TES technologies. tank of 11 m in diameter and 3.5 m in height.
• Comparative economic performance of the TES tech- Figure 1 shows the system concept of the overall CSP
nologies based on levelized cost of storage. plant as well as the three TES configurations compared
in this study. In the case of the one-tank packed-bed sys-
tem, during the charging phase, the hot HTF enters from
2 | PLANT CONFIGURATION the top of the tank and releases the heat to the solid
media or PCM, charging the TES system and generating
2.1 | Current configuration a thermocline along the axis of the bed. Conversely, dur-
ing the discharging phase, the cold thermal oil enters
As mentioned above, a real medium-scale CSP plant run- from the bottom of the tank in reversed flow, absorbs the
ning at Ottana (Italy)36 is considered as case study. At heat from the solid media or PCM, and exits from
present, this solar facility integrates as a vital sub-system, the top.
a two-tank direct TES unit for accumulating the solar Table 1 reports the thermal properties of the various
thermal energy produced in the solar field. At nominal storage media considered in this study. In the packed-bed
CASCETTA ET AL. 17725
case, silica is used as solid storage medium due to its shell made of steel with a thickness of 1 mm are placed
low specific costs and the large range of operating con- at the top of the bed. The void between the capsules is
ditions this material can operate without large varia- filled with sand. The PCM is made of molten salt
tions in its thermal properties. According to Bruch (KNO3 60% + NaNO3 40%) and it has a melting temper-
et al,27 a mix of rock and sand with a distribution of ature of 221 C. This choice was made for technical rea-
80% and 20% is chosen to reduce the bed void fraction sons since the melting point temperature is the
of the packed bed. The diameter of rock and sand are minimum acceptable temperature to avoid substantial
set to 30 mm and 3 mm respectively. In the solid degradation in the ORC performance (this effect will be
+ PCM case, the 90% in volume of the TES is consti- analysed in Section 3.3), but also because it is a proven
tuted by silica rock and sand as in the previous case, and commercially available medium commonly used in
while PCM capsules having a diameter of 25 mm and a CSP systems. Both beds with and without PCM have a
17726 CASCETTA ET AL.
porosity set to 0.27, while for the capsules, filling coeffi- 3.1 | Fresnel solar field
cient was taken as 0.85, to make room for fluid expan-
sion when undergoing the melting process. The performance of the solar field (Fresnel type) mainly
Based on storage media characteristics and current depends on some environmental parameters, such as the
vessel volume (330 m3), the maximum storage capacities available DNI, solar azimuth, ambient temperature, and
38
of the three alternative TES configurations are deter- wind speed. According to Cocco et al, the solar thermal
mined and highlighted below (Table 2). By considering _
power input into the receiver QINC is given by the prod-
the current two-tank TES configuration as reference, an uct of the solar field collecting area ASF , the reference
increase of about 45% and 55% in the maximum storable optical efficiency ηOPT,R , the Incidence Angle Modifier
energy is determined for the packed-bed and packed-bed (IAM), the end-loss optical efficiency ðηEND Þ and the sur-
+ PCM systems, respectively. Furthermore, substantial face cleanliness efficiency ηCLN , as:
reduction in the mass of oil used as storage medium
(about 65%) is observed in the one-tank alternatives, with Q_ REC ¼ DNI ASF ηOPT,R IAM ηEND ηCLN ð1Þ
a significant consequence in the cost-effectiveness of the
TES system. The Incidence Angle Modifier, calculated as product
of the longitudinal (IAML ) and transversal (IAMT ) com-
ponents, is determined as a polynomial function of the
3 | MATHEMATICAL MODELS longitudinal and transversal components θL and θT of
the solar incidence angle:
This section introduces the mathematical models devel-
oped in MATLAB-SIMULINK for the simulation of the IAML ¼ 1:004 1:311 102 θL þ 3:471 104 θ2L 8:860
three TES configurations compared in this study, as well 106 θ3L þ 5:822 108 θ4L
as the other units of the CSP-ORC plant. Thermal proper- ð2Þ
ties of the HTF declared by manufacturer37 are taken as
reference, while the main design assumptions are IAMT ¼ 0:9942 þ 1:23 103 θT 4:659 104 θ2T þ 1:998
reported in Table 3. 105 θ3T 3:242 107 θ4T þ 1:586 109 θ5T ð3Þ
TABLE 2 Mass of solid or liquid media used to store energy and maximum energy stored for each case
∂TBED
ð1 εÞðρcÞBED ¼ αAS ðTHTF TBED Þ ð11Þ
3.2.1 | Two-tank direct TES ∂t
According to Petrollese and Cocco,41 a zero- where ε represents the bed void fraction, keff the effective
dimensional modelling (namely, negligible thermal thermal conductivity of the overall bed, α the convective
stratifications inside the tanks) based on mass and heat transfer coefficient, ABED and ATANK the superficial
energy balances applied to the hot tank (HT) and cold area per unit of volume of the bed and of the tank,
tank (CT) was adopted for simulating the two-tank respectively, calculated according to previous studies.42,43
TES configuration: The convective heat transfer coefficient α is mainly a
17728 CASCETTA ET AL.
function of the Nusselt number according the following ϕ ¼ 1 ε β ¼ ðks kl Þ=ðks þ 2kl Þ ð17Þ
known correlation,44 while AS depends on the particle
diameter and void fraction: where ks and kl represent thermal conductivity of the
solid media (PCM or rock) and of oil, respectively.
Nu ¼ 2:0 þ 1:1 Rep 0:6 Pr0:33 ð12Þ
FIGURE 2 Responses of ORC net power by varying, A, mass flow rate and inlet temperature of HTF, B, water temperature at condenser
inlet
accumulated in the cold tank feeds the solar field. This Complete discharge occurs when all the thermal oil is
operating mode is active until all the thermal oil is stored in the cold tank for the case of two-tank direct
transferred to the hot tank. For the one-tank TES sys- storage or when the temperature of the HTF feeding
tems, the bed temperature increases gradually with the ORC is lower than 200 C, which is considered as
inflow of hot HTF from solar field, and the HTF leav- the minimum acceptable by the ORC unit.
ing the tank from the bottom returns to the solar field.
With the rise in the average temperature of the packed
bed, an increase in the thermal oil leaving the tank 4 | RESULTS A ND DISCUSSION
occurs. Consequently, the rotational speed of the solar
field circulation pump is adjusted to keep the outlet oil The expected performance of the CSP plant with differ-
temperature close to the set value raising the HTF ent TES configurations is presented and analysed in this
mass flow rate. This operation mode remains active section. To begin with, the plant performance is
until the pump reaches its maximum speed and the reported for a typical summer day (day 240) character-
ORC is then switched on, since this condition is veri- ized by clear sky conditions, chosen such that, starting
fied when the TES can be considered charged. from a completely discharged TES, all the operating
• Solar-to-ORC + TES. The operational ORC unit is set modes mentioned above occur during the day. Next,
to the nominal electrical power value (629 kW net). the yearly performance to be expected of the plant is
The HTF mass flow rate feeding the turbogenerator is analysed.
adjusted by means of a variable speed pump while the
HTF circulating in the solar field exceeds the thermal
power demanded by the turbogenerator. Consequently, 4.1 | Daily performance
the excess is stored in the TES section. The cold oil
exiting the ORC is sent to the cold tank (two-tank case) On the specified summer day chosen for analysis, the
or mixed with the thermal oil leaving the TES system simulation results for the case of one-tank thermocline
and sent back to the solar field (one-tank case). packed-bed system filled with rock and sand are shown
• Solar + TES-to-ORC. The mass flow rate of inlet HTF in Figure 3. As can be seen, the HTF mass flow rate
required for ORC operation at design conditions would (Figure 3A) circulates in the solar field for almost
not be sufficiently satisfied by the hot solar field HTF. 12 hours (from 5.30 AM to 5.30 PM). Since the solar field
Therefore, the TES system is discharged to make up control system is set to maintain the exit temperature of
for disparity in the thermal energy required for the the HTF at the design value, as much as possible, a varia-
ORC to operate at nominal conditions. tion of the mass flow rate with the solar radiation occurs.
• TES-to-ORC. The solar field does not produce thermal In the first part of the day, the Solar-to-TES operating
energy and the ORC plant is exclusively fed by the TES mode is active and all the HTF heated up in the solar
system until the latter is completely discharged. field is used to charge the TES system. For this reason, as
17730 CASCETTA ET AL.
F I G U R E 3 A, HTF mass flow rates and, B, correlated thermal power flows produced by the solar field and required by the ORC unit, C,
consequent HTF mass flow rates and, D, correlated thermal power flows obtained during the charging and discharging phase of the TES
system on a given summer day
shown in Figure 3C, the HTF mass flow rate sent to TES approaching its full-charge state. In this case, a signifi-
unit has the same trend of the mass flow rate coming cant rise in the HTF mass flow rate is not reflected in the
from the solar field. The TES system is fully charged after thermal power due to a corresponding reduction in tem-
about 7 hours (at about 12:30 PM). This condition can be perature difference between solar field inlet and outlet
observed through the quick increase of the rate of mass sides. Furthermore, the HTF temperature decrease dur-
flow of the HTF through the solar field up to almost ing the last discharging period leads to a reduced thermal
18 kg/s (the maximum value allowable in the solar field), power input into the ORC plant (at constant HTF mass
when the TES is approaching its full charge state. flow rate) and, consequently, to a decrease in the electri-
According to the implemented operating modes, the cal power produced. As already observed for the mass
ORC unit is then started. Apart from a short period, flow rates, during the morning the trend of the thermal
when the thermal energy produced in the solar field goes energy flowing into the storage system for charging over-
beyond the thermal demand of the turbogenerator and laps the solar field thermal power curve. Similarly, when
the share of the solar field HTF mass flow is sent to the the TES-to-ORC mode is activated, the thermal power
TES section (Solar to TES + ORC), the operating mode feeding the ORC unit coincides with the thermal power
Solar + TES-to-ORC is active during the last part of the discharged by the TES section.
daytime. In fact, the solar field is unable to guarantee To further explain the phenomena occurring during
the thermal power requested by the ORC unit and the the charge and discharge phase of the packed-bed system,
storage system is therefore discharged to make up the Figure 4 highlights how the temperature profile of both
energy deficit, as shown in Figure 3C. This operating con- solid media and oil evolve over time while charging
dition remains active up to about 5 PM, when the solar (Figure 4A) and discharging (Figure 4B). The initial pro-
field is deactivated and only the TES system supplies the file represents the thermal condition of the TES system at
ORC plant (TES-to-ORC). This operating condition ends midnight as residual condition of the previous day. Up to
when the TES system is substantially discharged, namely 6 AM, the TES system is inactive and both thermal losses
when the temperature of the oil supplied by the hot tank towards the external ambient and the thermal conductiv-
drops to 200 C, taken as the minimum acceptable tem- ity within the bed slightly modify the shape of the ther-
perature by the ORC. mocline. When the charge phase begins, the hot oil
As shown in Figure 3B, the thermal power produced enters from the top of the bed, and layers of the bed grad-
by the solar field follows a similar trend of the HTF mass ually increase their temperature beginning from the top
flow rate apart from periods in which the temperature up to a maximum of about 260 C. When the TES system
variations from their nominal values become predomi- is fully charged, in accordance with the plant manage-
nant. This occurrence can be observed close to the start- ment, the temperature of the bottom layer of the bed
up and shutdown of the solar field and when the TES is reaches about 200 C. At about 12:30 PM, the flow
CASCETTA ET AL. 17731
FIGURE 4 Evolution of the thermocline profiles over time during, A, the charge phase and, B, discharge phase, using rock and sand as
solid media
F I G U R E 5 Transient evolution of the thermocline profiles during, A, the charge phase and, B, discharge phase using rock, sand and
PCM as solid media
reverses, and the TES starts to discharge accumulated completes when the heated oil exiting the top of the tank
energy. During the first part of the discharge phase attains a temperature still acceptable for the ORC unit to
(Figure 4B), the overall system is in the “Solar + TES to operate in an efficient way (200 C).
ORC” operating mode, since the HTF flowing through The substitution of a layer of the bed made by rock
the TES system must compensate the lacking mass flow and sand with PCM capsules at the top of the bed is then
rate needed to reach a nominal value of about 12 kg/s investigated as a viable alternative. The height of the
requested by the ORC plant. After 5 PM, the solar field PCM layer has been assumed equal to 10% of the overall
becomes inoperative, therefore, only the TES system bed height. In Figure 5, a vertical dashed line placed at
feeds the ORC plant, (“TES to ORC” operating mode). 0.35 m along the x-axis divides the bed into two zones.
The discharge phase lasts for about 9 hours and almost The zone at the left of the dashed line represents the side
all the bed reaches gradually the minimum value of of the bed with PCM + sand, while the other to the right
about 155 C, except in the last layer at the top where the is the zone with rock and sand. Obviously, the inclusion
temperature remains higher. Indeed, this phase of the PCM layer introduces a significant difference in
17732 CASCETTA ET AL.
F I G U R E 6 Mass flow rate and temperature of the ORC inlet HTF for, A, the two-tank direct TES configuration, B, the one-tank packed-
bed filled with rock and sand and, C, the one-tank packed-bed with the addition of a PCM layer at the top of the tank
the evolution of the thermocline, compared with that Figure 6 shows the main trends obtained for the two
obtained in the previous case. By referring to Figure 5A, performance variables during the considered day for the
the PCM capsules in the first part of the charge phase are three TES configurations analysed. For the same volume
heated by the HTF and their temperature increases until of the tank, the higher energy capacity introduced with
reaching the melting temperature (221 C). During melt- the packed-bed configurations results in an increase in
ing, the temperature of PCM increases very slowly due to the continuous operating hours of the ORC unit.
the latent heat of fusion, generating a step within the Another considerable effect in using packed-bed config-
bed. Once the PCM is completely melted, the tempera- urations is related to the ability to shift the ORC produc-
ture increases faster, and the profile of the thermocline tion towards night-time: in Figure 6 it is possible to
returns to be similar to that already shown in the case observe the start-up phase postponed by about 2 hours
without PCM. During the discharge phase, the effect of for the one-tank configuration relative to the two-tank
introducing a PCM layer becomes evident when the TES alternative and the ORC is in operation until midnight.
is almost completely discharged and the PCM reaches its Consequently, the ORC unit generally operates with
melting temperature (221 C). Analogously to the charge lower ambient temperatures. This fact is beneficial to
phase, the temperature remains almost constant during the ORC conversion efficiency, since dry coolers can
the solidification process, therefore the HTF temperature reduce the inlet temperature of cooling water with a
calculated at the outlet section of the tank decreases consequent reduction in the condenser pressure. On the
more slowly, thereby mitigating the drop in ORC perfor- other hand, significant variations in the delivered tem-
mance due to low HTF inlet temperature. perature occur in one-tank configurations due to the
intrinsic characteristics of the packed-bed to store a
medium at different temperature, unlike the use of a
4.1.1 | Comparison with the current TES dedicated tank for storing the hot oil as in the two-tank
configuration (two-tank) configuration. Consequently, decrease in the ORC net
power occurs for the one-tank configurations, especially
Behaviour of the three different TES configurations towards the night-time, when the TES systems are
(namely, the current two-tank direct storage, one-tank approaching full discharge. The introduction of a PCM
packed-bed filled with rock and sand and the latter layer only mitigates this performance drop and its effect
topped with additional PCM layer) were compared with becomes evident for almost 1 hour. On the other hand,
respect to the conditions on the chosen day. Mass flow a limited temperature variation, mainly due to imperfect
rate and temperature of the ORC inlet HTF were the insulation of the hot tank, is observed by considering
main performance variables considered for this analysis, the two-tank case. Accordingly, the ORC unit can oper-
reflecting respectively the quantity and quality of the ate close to its nominal condition with marginal varia-
thermal energy ready for supply into the ORC plant. tions in the conversion efficiency.
CASCETTA ET AL. 17733
TABLE 4 Comparison of the expected yearly system performance based on the different TES configurations
4.2 | Yearly analysis without any TES system. The latter is taken as a refer-
ence for assessing the energy benefit arising from the
Annual weather and environmental data were obtained inclusion of an energy storage system in the considered
for the Ottana site using Meteonorm software,47 and they solar plant. The existing two-tank direct TES case over-
form the basis for yearly performance evaluation of the comes the instability of the thermal power generated by
solar plant. Figure 7 shows the daily electricity produc- the solar field. The presence of this TES device raises the
tion during one year of operation in the case of the one- ORC mean yearly efficiency up to a value of 19.7% and
tank configuration filled with rock and sand. A very simi- the ORC electrical energy production up to 0.92 GWh per
lar distribution of the daily electrical energy production year. The ORC unit operates only when the hot tank is
is obtained with the other two TES configurations almost full, providing, therefore, hot oil at a mass flow
analysed due to the similar storage capacity. As expected, rate and temperature quite stable close to the nominal
most of the annual electricity production is concentrated values, allowing to raise the main performance
during summer, when daily energy production over indicators.
10 MWh is reached, while during winter the ORC unit is Since the HTF temperature feeding the ORC unit was
operative only one day per week on average. observed to be well below the nominal value for the one-
Table 4 reports the main performance indexes of the tank configuration, it results in a reduction of the mean
two proposed configurations compared to the actual one yearly ORC efficiency, which is about 18.2% when con-
with two-tank direct TES and with the CSP-ORC plant sidering the packed-bed TES with silica. The introduction
17734 CASCETTA ET AL.
TABLE 5 Assumptions and results of the preliminary economic assessment for the different TES configurations49-52
of a layer with encapsulated PCM ameliorates this draw- 25 years. The CAPEXTES were arrived at considering the
back but the effect is quite marginal, since the mean market unit cost of each vessel. Specifically, total capital
ORC efficiency rises only to 18.3%. Conversely, adopting costs were obtained by adding unit costs for the number
a one-tank system with a lower average temperature of tanks involved, which can be 1 or 2 depending on the
strongly reduces the TES thermal losses towards the envi- chosen TES configuration, added also to the costs of
ronment. Furthermore, an increase in the solar field the storage media, proportional to the mass amount of
annual production is also observed compared to the two- HTF, Silica rock and sand and encapsulated PCM. The
tank system, since the overall receiver thermal losses are yearly operational costs are taken as 3% of the capital
lower. costs. The CAPEX would be expected to reduce signifi-
Consequently, the annual electricity production cantly with the use of the one-tank packed-bed unit,
obtained by the three TES configurations analysed is apparently as a result of savings made in the purchase of
almost the same (0.92 GWh/year), confirming that the vessels, as reported in Table 5. Moreover, a more
two alternative solutions based on a single tank are a favourable unit cost of the silica compared to thermal oil
valid alternative to the current two-tank system in use. decreases further the capital investment. Consequently, a
reduction of more than 45% in the capital investment
costs of TES system is observed with the adoption of a
4.3 | Preliminary economic analysis one-tank packed-bed TES, relative to the two-tank alter-
native. This fact, combined with the equivalent annual
The prospective economic benefit of the alternative TES energy production obtained irrespective of the TES tech-
configurations is assessed in this section. The solar field nology, results in a significant reduction of the achieved
and ORC unit are already installed, thus, the preliminary LCOS with the adoption of a one-tank TES. In particular,
economic assessment concerns only the storage units. In the use of the sole packed bed made by rock and sand
view of this, the economic assessment uses levelized cost gives the lowest LCOS (0.234 €/kWh), while the introduc-
of storage (LCOS)48 as a performance index, defined as: tion of a PCM layer seems to provide no economic
benefit.
P OPEXTES
CAPEXTES þ N k¼1 ð1þrÞk
LCOS ¼ P N ECSPþTES ECSP,only ð18Þ
k¼1 ð1þrÞ k
5 | CONCLUSIONS
with CAPEXTES representing the capital expenditures of Performance of different TES configurations have been
the TES section, and OPEXTES the yearly operational assessed for medium-scale CSP systems, with reference to
expenditures of the TES unit. The expected yearly energy a real CSP-ORC plant rated nominally at 629 kW. The
production, ECSPþTES , refers to the production of the CSP CSP-ORC plant currently operates with a two-tank direct
plant with integrated TES unit, while ECSP,only represents TES system using Therminol SP-I as storage medium and
the yearly energy produced by the CSP section only, with- HTF. In this paper, the effects on the CSP-ORC plant of a
out any thermal storage device. The interest rate i is one-tank packed-bed TES using rock and sand as storage
taken as 5%, while the TES system lifetime N is taken as media and another similar one with integrated PCM were
CASCETTA ET AL. 17735
comparatively assessed, against the existing two-tank sys- m_ mass flow rate (kg/s)
tem. The main findings of the study are: OPEX operating expenditures (€/year)
Q_ thermal power (W)
• The use of a one-tank packed bed TES system T temperature (K)
increased annual thermal energy output of the solar t time (s)
field to about 5.1 GWht, around 5% higher than that U overall heat transfer coeff. (W/m2 K)
obtained with the use of the two-tank direct system. V volume (m3)
Similarly, the study revealed that adoption of a one- α convective heat transfer coeff. (W/m2 K)
tank TES system in the CSP-ORC plant would reduce ε void fraction
annual thermal energy loss in the TES system to about η efficiency
one-third of what currently obtains. Consequently, a ρ density (kg/m3)
rise in the annual thermal energy feeding the ORC AMB ambient conditions
unit (about 5 GWht) is expected with the use of a one- CLN cleanliness
tank system, compared to about 4.7 GWht obtainable CT cold tank
with the two-tank TES system. HT hot tank
• Overall, about 0.92 GWh of electrical energy is pro- I inlet side
duced by the ORC annually, irrespective of the TES O outlet side
configuration employed. Thus, in juxtaposition with OPT optical
the annual thermal energy input into the ORC REC receiver
reported above for the different TES configurations, it SF solar field
is obtained that adoption of a one-tank TES system CSP concentrated solar power
reduces mean ORC efficiency by about 1.5% points. DNI direct normal irradiance
• Lack of constraints in temperature of the oil exiting HTF heat transfer fluid
the one-tank packed bed TES system allowed for a LCOS levelized cost of storage
greater amount of thermal energy available to be ORC organic Rankine cycle
exploited during the discharging phase. Additionally, PCM phase change material
this choice had the obvious advantage of canceling the TES thermal energy storage
hysteresis effect usually generated after consecutive
charge/discharge cycles, that would have degraded the A C KN O WL ED G EME N T S
thermocline shape with significant reduction of The study reported in this paper received funding from
the thermal energy available for input into the ORC P.O.R. SARDEGNA F.S.E. 2014-2020—Axis III Education
plant. and Training, Thematic Goal 10, Specific goal 10.5,
• The one-tank packed-bed system is economically via- Action partnership agreement 10.5.12—“Call for funding
ble due to the reduced cost of investment. Conse- of research projects—Year 2017.” The authors gratefully
quently, a reduction of more than 45% in the levelized acknowledge ENAS for granting access to the operational
cost of storage can be achieved compared to the two- data of the Ottana Solar Facility.
tank configuration, while the integration of a PCM
layer seems not to introduce any economic benefit. ORCID
Mario Petrollese https://orcid.org/0000-0001-5394-1419
In the near future, a further experimental campaign
on the CSP plant is scheduled with the aim of increasing RE FER EN CES
the reliability of the simulation models adopted and the 1. OECD. World Energy Outlook 2018; 2018.
robustness of the results obtained in this study. 2. Modi A, Bühler F, Andreasen JG, Haglind F. A review of solar
energy based heat and power generation systems. Renew Sus-
NO MEN CLATU RE tain Energy Rev. 2017;67:1047-1064. https://doi.org/10.1016/J.
RSER.2016.09.075.
3. Bouhal T, Aqachmar Z, Kousksou T, El Rhafiki T, Jamil A,
A area (m2) Zeraouli Y. Energy and economic assessment of a solar air-
c specific heat (J/kg K) conditioning process for thermal comfort requirements. Sol Energy.
CAPEX capital expenditures (€) 2020;208:101-114. https://doi.org/10.1016/j.solener.2020.07.045.
E energy (Wh) 4. Vengadesan E, Senthil R. A review on recent development of
k thermal conductivity (W/m K) thermal performance enhancement methods of fl at plate solar
h specific enthalpy (J/kg) water heater. Sol Energy. 2020;206:935-961. https://doi.org/10.
L latent heat (J/kg) 1016/j.solener.2020.06.059.
17736 CASCETTA ET AL.
5. Esmaeli H, Roshandel R. Optimal design for solar greenhouses 20. Alva G, Liu L, Huang X, Fang G. Thermal energy storage mate-
based on climate conditions. Renew Energy. 2020;145:1255- rials and systems for solar energy applications. Renew Sustain
1265. https://doi.org/10.1016/j.renene.2019.06.090. Energy Rev. 2017;68:693-706. https://doi.org/10.1016/j.rser.
6. Hernandez-Callejo L, Gallardo-Saavedra S, Alonso-G omez V. A 2016.10.021.
review of photovoltaic systems: design, operation and mainte- 21. Kuravi S, Trahan J, Goswami DY, Rahman MM,
nance. Sol Energy. 2019;188:426-440. https://doi.org/10.1016/j. Stefanakos EK. Thermal energy storage technologies and sys-
solener.2019.06.017. tems for concentrating solar power plants. Prog Energy Combust
7. Santos JJCS, Palacio JCE, Reyes AMM, Carvalho M, Sci. 2013;39:285-319. https://doi.org/10.1016/j.pecs.2013.02.001.
Freire AJR, Barone MA. Concentrating solar power. Adv Renew 22. Xu C, Wang Z, He Y, Li X, Bai F. Sensitivity analysis of the
Energies Power Technol. 2018;1:373-402. https://doi.org/10. numerical study on the thermal performance of a packed-bed
1016/B978-0-12-812959-3.00012-5. molten salt thermocline thermal storage system. Appl Energy.
8. Raboaca MS, Badea G, Enache A, et al. Concentrating solar 2012;92:65-75. https://doi.org/10.1016/j.apenergy.2011.11.002.
power technologies. Energies. 2019;12:1048. https://doi.org/10. 23. Singh H, Saini RP, Saini JS. A review on packed bed solar
3390/en12061048. energy storage systems. Renew Sustain Energy Rev. 2010;14:
9. Achkari O, El Fadar A. Latest developments on TES and CSP 1059-1069. https://doi.org/10.1016/j.rser.2009.10.022.
technologies—energy and environmental issues, applications 24. Good P, Zanganeh G, Ambrosetti G, Barbato MC, Pedretti A,
and research trends. Appl Therm Eng. 2020;167:114806. https:// Steinfeld A. Towards a commercial parabolic trough CSP sys-
doi.org/10.1016/j.applthermaleng.2019.114806. tem using air as heat transfer fluid. Energy Procedia. 2013;49:
10. Islam T, Huda N, Abdullah AB, Saidur R. A comprehensive 381-385. https://doi.org/10.1016/j.egypro.2014.03.041.
review of state-of-the-art concentrating solar power (CSP) tech- 25. Hoffmann J, Fasquelle T, Goetz V, Py X. A thermocline ther-
nologies: current status and research trends. Renew Sustain mal energy storage system with filler materials for concen-
Energy Rev. 2018;91:987-1018. https://doi.org/10.1016/j.rser. trated solar power plants: experimental data and numerical
2018.04.097. model sensitivity to different experimental tank scales. Appl
11. Gomez-vidal J, Or E, Kruizenga A, Fern AG, Cabeza LF, Sol A. Therm Eng. 2016;100:753-761. https://doi.org/10.1016/j.
Mainstreaming commercial CSP systems: A technology review. applthermaleng.2016.01.110.
Renew Energy. 2019;140:152-176. https://doi.org/10.1016/j. 26. Bruch A, Fourmigue JF, Couturier R, Molina S. Experimental
renene.2019.03.049. and numerical investigation of stability of packed bed thermal
12. Dinter F, Gonzalez DM. Operability, reliability and economic energy storage for CSP power plant. Energy Procedia. 2014;49:
benefits of CSP with thermal energy storage: first year of opera- 743-751. https://doi.org/10.1016/j.egypro.2014.03.080.
tion of ANDASOL 3. Energy Procedia. 2014;49:2472-2481. 27. Bruch A, Fourmigué JF, Couturier R. Experimental and
https://doi.org/10.1016/j.egypro.2014.03.262. numerical investigation of a pilot-scale thermal oil packed bed
13. Pacheco JE, Showalter SK, Kolb WJ. Development of a molten- thermal storage system for CSP power plant. Sol Energy. 2014;
salt thermocline thermal storage system for parabolic trough 105:116-125. https://doi.org/10.1016/j.solener.2014.03.019.
plants. J Sol Energy Eng. 2002;124:153-159. https://doi.org/10. 28. Couturier R, Bruch A, Molina S, Esence T, Fourmigu JF.
1115/1.1464123. Experimental investigation of cycling behaviour of pilot-scale
14. Pelay U, Luo L, Fan Y, Stitou D, Rood M. Thermal energy stor- thermal oil packed-bed thermal storage system. Renew Energy.
age systems for concentrated solar power plants. Renew Sustain 2017;103:277-285. https://doi.org/10.1016/j.renene.2016.11.029.
Energy Rev. 2017;79:82-100. https://doi.org/10.1016/j.rser.2017. 29. Rodat S, Bavière R, Bruch A, Camus A. Dynamic simulation of
03.139. a Fresnel solar power plant prototype with thermocline ther-
15. Oyekale J, Heberle F, Petrollese M, Brüggemann D, Cau G. mal energy storage. Appl Therm Eng. 2018;135:483-492. https://
Biomass retrofit for existing solar organic Rankine cycle power doi.org/10.1016/j.applthermaleng.2018.02.083.
plants: conceptual hybridization strategy and techno-economic 30. Rodat S, Bruch A, Dupassieux N, El Mourchid N. Unique Fres-
assessment. Energ Conver Manage. 2019;196:831-845. https:// nel demonstrator including ORC and thermocline direct ther-
doi.org/10.1016/j.enconman.2019.06.064. mal storage: operating experience. Energy Procedia. 2015;69:
16. Oyekale J, Petrollese M, Vittorio T, Cau G. Conceptual 1667-1675. https://doi.org/10.1016/j.egypro.2015.03.127.
design and preliminary analysis of a CSP-biomass organic 31. Chacartegui R, Vigna L, Becerra JA, Verda V. Analysis of two
Rankine cycle plant. 31st Int. Conf. Effic. Cost, Optim. heat storage integrations for an organic Rankine cycle para-
Simul. Environ. Impact Energy Syst. ECOS 2018, Guimaraes; bolic trough solar power plant. Energ Conver Manage. 2016;
Port; 2018. 125:353-367. https://doi.org/10.1016/j.enconman.2016.03.067.
17. Enescu D, Chicco G, Porumb R, Seritan G. Thermal energy 32. Rodríguez JM, Sanchez D, Martínez GS, et al. Techno-
storage for grid applications: current status and emerging economic assessment of thermal energy storage solutions for a
trends. Energies. 2020;13:340. https://doi.org/10.3390/ 1 MWe CSP-ORC power plant. Sol Energy. 2016;140:206-218.
en13020340. https://doi.org/10.1016/j.solener.2016.11.007.
18. Reddy KS, Mudgal V, Mallick TK. Review of latent heat ther- 33. Galione PA, Pérez-segarra CD, Rodríguez I, Lehmkuhl O,
mal energy storage for improved material stability and effective Rigola J. A new thermocline-PCM thermal storage concept for
load management. J Energy Storage. 2018;15:205-227. https:// CSP plants . Numerical analysis and perspectives. Energy Procedia.
doi.org/10.1016/J.EST.2017.11.005. 2014;49:790-799. https://doi.org/10.1016/j.egypro.2014.03.086.
19. Kerskes H. Chapter 17—thermochemical energy storage. In: 34. Galione PA, Pérez-Segarra CD, Rodríguez I, Oliva A, Rigola J.
Letcher TMBT-SE, editor. . Oxford: Elsevier; 2016:345-372. Multi-layered solid-PCM thermocline thermal storage concept for
CASCETTA ET AL. 17737
CSP plants. Numerical analysis and perspectives. Appl Energy. 45. Jefferson CP. Prediction of breakthrough curves in packed
2015;142:337-351. https://doi.org/10.1016/j.apenergy.2014.12.084. beds. AIChE J. 1972;18:409-420.
35. Zanganeh G, Commerford M, Haselbacher A, Pedretti A, 46. Petrollese M, Dickes R, Lemort V. Experimentally-validated
Steinfeld A. Stabilization of the outflow temperature of a models for the off-design simulation of a medium-size solar
packed-bed thermal energy storage by combining rocks with organic Rankine cycle unit. Energ Conver Manage. 2020;224:
phase change materials. Appl Therm Eng. 2014;70:316-320. 113307. https://doi.org/10.1016/j.enconman.2020.113307.
https://doi.org/10.1016/j.applthermaleng.2014.05.020. 47. Meteotest. Meteonorm Software—Worldwide irradiation data; n.d.
36. Petrollese M, Cau G, Cocco D. The Ottana solar facility: dis- 48. Petrollese M, Arena S, Cascetta M, Casti E, Cau G. Techno-
patchable power from small-scale CSP plants based on ORC economic comparison of different thermal energy storage tech-
systems. Renew Energy. 2018;147:2932-2943. https://doi.org/10. nologies for medium-scale CSP plants. AIP Conf Proc. 2019;
1016/j.renene.2018.07.013. 2191:020128. https://doi.org/10.1063/1.5138861.
37. Therminol SP. Heat Transfer Fluid j Therminol j Eastman; n.d. 49. Cocco D, Serra F. Performance comparison of two-tank direct
38. Cocco D, Migliari L, Petrollese M. A hybrid CSP–CPV system and thermocline thermal energy storage systems for 1MWe
for improving the dispatchability of solar power plants. Energ class concentrating solar power plants. Energy. 2015;81:526-
Conver Manage. 2016;114:312-323. https://doi.org/10.1016/j. 536. https://doi.org/10.1016/j.energy.2014.12.067.
enconman.2016.02.015. 50. Pereira da Cunha J, Eames P. Thermal energy storage for low
39. Forristall R. Heat transfer analysis and modeling of a parabolic and medium temperature applications using phase change
trough solar receiver implemented in engineering equation materials—a review. Appl Energy. 2016;177:227-238. https://
solver; 2003. doi.org/10.1016/j.apenergy.2016.05.097.
40. Cocco D, Migliari L, Serra F. Influence of thermal energy losses 51. Gil A, Castell A, Oro E, Cabeza BLF, Sole C. Review of solar
on the yearly performance of medium size CSP plants. ECOS thermal storage techniques and associated heat transfer tech-
2015—28th Int. Conf. Effic. Cost, Optim. Simul. Environ. nologies. Environ Sci. 2012;100:525-538.
Impact Energy Syst., 2015. 52. Fritsch A, Frantz C, Uhlig R. Techno-economic analysis of
41. Petrollese M, Cocco D. Techno-economic assessment of hybrid solar thermal power plants using liquid sodium as heat transfer
CSP-biogas power plants. Renew Energy. 2020;155:420-431. fluid. Sol Energy. 2019;177:155-162. https://doi.org/10.1016/j.
https://doi.org/10.1016/j.renene.2020.03.106. solener.2018.10.005.
42. Cascetta M, Cau G, Puddu P, Serra F. A comparison between
CFD simulation and experimental investigation of a packed-bed
thermal energy storage system. Appl Therm Eng. 2016;98:1263-
1272. https://doi.org/10.1016/j.applthermaleng.2016.01.019. How to cite this article: Cascetta M,
43. Cascetta M, Serra F, Arena S, Casti E, Cau G, Puddu P. Experi- Petrollese M, Oyekale J, Cau G. Thermocline vs.
mental and numerical research activity on a packed bed TES two-tank direct thermal storage system for
system. Energies. 2016;9:758. https://doi.org/10.3390/ concentrating solar power plants: A comparative
en9090758.
techno-economic assessment. Int J Energy Res.
44. Wakao N, Kaguei S. Heat and Mass Transfer in Packed Beds.
Topics in chemical engineering New York, NY; Gordon and
2021;45(12):17721-17737. https://doi.org/10.1002/
Breach Science Publishers; 1982. er.7005