Sections Reinforcement Mark: Column Footing Section S-4 1
Sections Reinforcement Mark: Column Footing Section S-4 1
Sections Reinforcement Mark: Column Footing Section S-4 1
RSB W/
10mmØ LAT. TIES
10 mm @ TIES 3 @ 50 mm
4 @ 100 mm 5 @ 200 mm
and REST 250 mm OC
N.G.L.
SECTIONS REINFORCEMENT
MARK REMARKS
.50 @ SUPPORT @ MIDSPAN @ SUPPORT @ MIDSPAN VERTICAL HOOPS
EARTHFILL
0.25 0.25
TOP: 2-16 mm WITH TOP: 2-10 mm RSB
BEDBARS 2-10 mm EXTRA BARS 10 MM RSB STIRRUPS
CLEARANCE BETWEEN RSB
0.218 SPACED AS FOLLOWS
4 @ 60mm, AND FINISHED SURFACE
0.073 COMP. GRAVEL BASE 2 @100 mm, 3 @ SHALL BE NOT LESS THAN
RB-1 50 mm LESS FINISHES
0.30
150 mm,
0.30
REST @ 200 mm
BOTTOM: 2-16 RSB BOTTOM: 2-16 mm ON CENTER
.30
SECTION WITH 2- 16 mm
.80 EXTRA RSB
0.30
0.30
150 mm, SHALL BE NOT LESS THAN
REST @ 200 mm 50 mm LESS FINISHES
ON CENTER
4 - 16mmØ BOTTOM: 2-16 mm RSB BOTTOM: 2-16 mm
WITH 2-12 mm
0.30 VERT. RSB W/
EXTRA RSB
10mmØ LAT.
TIES
0.30
.80
0.25 0.25
BEDBARS SP. @
0.30
0.30
0.275m O. C. B. W.
BOTTOM: 2-16 mm RSB BOTTOM: 2-16 mm
WITH 2-12 mm
EXTRA RSB
@ SUPPORT @ MIDSPAN
F2 PLAN CB M S
.30 0.30
0.25 0.25
TOP: 2-16 mm WITH TOP: 2-10 mm RSB
2-10 mm EXTRA BARS
0.30
0.30
BOTTOM: 2-16 RSB BOTTOM: 2-16 mm
WITH 2- 16 mm
EXTRA RSB
M S @ SUPPORT @ MIDSPAN
0.30 0.30
ALLAN A. ROSARIO PAUL DANIEL R. SALAS OIC-CHIEF, PLANNING & DESIGN DIVISION ASSISTANT REGIONAL DIRECTOR REGIONAL DIRECTOR
10 19