Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
INDEX
4.6 MANIFOLD................................................................................................................................................................ 46
5 ELECTRIC CABLE ............................................................................................................................................... 47
5.1 FAST EVO X/FLUENDO PLUS LNX ................................................................................................................... 47
5.2 FAST EVO X DISPLAY ........................................................................................................................................ 48
5.3 FAST R X/BRD LNX ............................................................................................................................................. 49
6 ERROR CODE ....................................................................................................................................................... 50
6.1 TROUBLESHOOTING- FAST EVO X/FLUENDO PLUS LNX .......................................................................... 51
6.1.1 Flashing (micro switch not correct)................................................................................................................. 51
6.1.2 Flashing (Temperature sensor out).................................................................................................................. 51
6.1.3 Flashing (No flame detected) ........................................................................................................................... 52
6.1.4 Flashing (Problem on the gas valve) ............................................................................................................... 53
6.1.5 flashing (Fume temperature too high) ............................................................................................................. 54
6.2 TROUBLESHOOTING-FAST R X/BRD LNX ............................................................................................................. 55
6.2.1 Flashing (Low voltage) .................................................................................................................................... 55
6.2.2 No ignition ....................................................................................................................................................... 55
6.2.3 Ignition but not successful ............................................................................................................................... 56
6.3 FAST EVO X DISPLAY ........................................................................................................................................ 57
6.3.1 E2 (Water temprerature sensor failure) ........................................................................................................... 57
6.3.2 E3 (igniton failure or flame lift) ....................................................................................................................... 58
6.3.3 E4 (gas vavle defective) ................................................................................................................................... 59
6.3.4 E5 (overheat) .................................................................................................................................................. 60
7 TECHNICAL SPECIFICATION.......................................................................................................................... 61
Page. 4 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
1 GENERAL INFORMATION
1.1 SIEZE & DIMENSIONS
1.1.1 FAST EVO X/FLUENDO PLUS LNX
Model a b c d e f g h i j k l m
11 110 40.8 117 234.1 310 25.8 3
580 47.8 58,8 97 210.8 225.2 23.3
14 125 72 147.8 264.6 370 22.8 0
LEGEND
A Hot water outlet
B Gas inlet
C Cold water inlet
Page. 5 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Model a b c d e f g h i j k l m
11 113 40.8 102 208 310 18.5 13.6
617 58.8 93.3 210.8 255.2 0.6 92.8
14 132 70 132 238 370 15.5 10.6
Page. 6 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
LEGEND
1 Reset
2 Temperature”-” button
3 Temperature ”+”button
4 “on/off” button
Page. 7 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
3
1
2
LEGEND
1 Knob
2 Scale of temperature
3 Led
If the LED is red fixed: the power of the batteries is too low, changed them.
If the LED Red blink 1 2 3 4 or 5 times: is an error code (see in the pragraphe Error Code).
If the LED is Orange: setting mode
Page. 8 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
LEGEND
1. Fume thermostat 8. PCB box
2. Exhaust hood 9. Flow sensor
3. Heat exchanger 10. Ignition PCB
4. Burner 11. knob
5. manifold 12. HMI
6. Overheat thermostat 13. Ignition and detection electrode
7. Gas valve 14. frame
Page. 9 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
LEGEND
1. Exhaust hood 8. Water gas valve
2. Heat exchanger
9. Overheat thermostat
3. Burner
10. Gas connect pipe
5. manifold
12. frame
6. PCB
13. fumes thermostat
7. Battery box
Page. 10 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
a b c d e f g h i j k l m o p q
Fast 58 446. 15 19 9 31 114. 79. 23. 3 25. 2. 21 9 47. 57.
EV 0 2 2 0 5 0 2 1 3 8 8 9 0 6 8 4
OX
11L
Fast 58 446. 37 115. 78. 23. 22.
EV 0 2 0 2 9 6 5
OX
14L
Page. 11 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
a b c d e f g h i j k l m o
FAST 617.4 485.8 152 190 95 310 114.2 52.8 53.2 18.4 13.5 210 96 93.3
RX
11L
FAST 617.4 485.8 370 115 52.3 53.7 15.5 10.6
RX
14L
Recommandations
Page. 12 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
LEGEND
1. Heat exchanger 12. Ignitor
2. Hot water outlet 13. Battery (number 2)
3. Burner 14. Hot water NTC sensor
4. Ignitor sensor 15. Knob for setting the temperature
5. Detection electrode 16. Fume safety sensor
6. Gas clapet in the valve gas 17. Cold water inlet
7. Principal gas clapet 18. Water filter
8. Adjutment gas 19. FLUX meter
9. Safety gas valve 20. Motor gas valve
10. Safety gas valve 21. Solenoid coil
11. Electronid PCB 22. Overheat sensor
Page. 13 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
LEGEND
1 Heat exchanger 7 Magnetic plug
2 Wet chamber 8 Water valve
3 Burner 9 Control unit
4 Ignition electrode 10 Over heat thermostate
5 Ionisation electrode 11 Safety exhaust fume
6 Gas valve
Page. 14 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
2 OPERATION LOGIC
2.1 FAST EVO X/FLUENDO PLUS LNX
Rod (17), can adjust water flow, filter (18) can pick
out the impurity of water, water flow sensor (19)
can measure water flow rate.
Page. 15 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Ignition cycle
Ignitor (12) Safety gas valve (9 et 10) Gas valve (20 et 21)
Detection (5)
Page. 16 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
C D
Turn on the power switch, when the tap is turned on, the water flow is more than (2L/min) or the water
pressure is higher than 0.2bar, the micro-switch (15) gives the electrical signal to the ignition controller (A).
Control PCB to receive the signal, drive the ignition, 0.5s after the solenoid valve (20) open. Gas from the
intake connection (21) goes to the solenoid valve (20), and then goes to the gas regulating shaft (19), goes
to the linkage body (14), next goes to manifold and burner (B), start ignition. Ignition is successful, flame
electrode (C) sensor provides flame signal to controller box, and ignition pin (C) stop spark and machine
continue to work.
The thermostat (D) monitor water temperature inside HEX, when the water temperature is more than 85℃ ,
the machine stops working.
Page. 17 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
The thermostat (E) monitor water temperature inside HEX, when exhaust gas goes out of flue hood and flue
hood temperature exceeds 145 ℃, the machine stops working. (Machine only for RU market has this
function)
Right knob(9) , can adjust water flow rate, filter (7) eliminater particles in water;
Left knob(17) , can adjust gas flow rate.
Microswitch ON
Open valve
Detect flame
Stop ignition
Normal working
Stop working
Page. 18 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
MIN MAX
TEMPERATURE
RANGE 35°C 65°C
FLAME CHECK
OFF : 65°C
ON : 60°C
Page. 19 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
MIN MAX
TEMPERATURE
RANGE 35°C 65°C
FLAME CHECK
FONCTIONNEMENT NORMAL
The temperature is checked by the outlet
thermostat. During the flow rate variations and
during the ignition the power is managed by the
rod .
Page. 20 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
If the appliance is installed where is possible that the temperature goes down 5°C, we suggest to drain the
water.
T° maxi 90°C
Page. 21 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
3 HYDRAULIC COMPONENTS
3.1 FAST EVO X/FLUENDO PLUS LNX
Water flow
sensor
Filter
Inlet cold
water
Selector of
water flow
Reed sensor
Cold water
connector
Flow meter
Filter
Flow meter
Selector of
water flow
Page. 22 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
NTC sensor
outlet
Hot water
connection
NTC outlet
sensor
Page. 23 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
In the inlet hydraulic block there is the filter, accessible from the bottom of the appliance.
Filter
Connector
and filter
Page. 24 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
When there is a sanitary tap, the flow of water passes through the turbine that allows the electronic card to
measure the flow by means of a reed sensor.
The sanitary flow meter is used to detect the tap and also to calculate the power.
Turbine
To check the inlet temperatures, the appliance used immersion NTC sensor, located in the inlet hydraulic
block.
0 23730
10 15450
20 10310
30 7037
40 4905
50 3485
60 2521
70 1853
80 1384
NTC outlet
sensor
Page. 25 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Datas:
Page. 26 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 27 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Datas:
Page. 28 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
4 GAS
4.1 FAST EVO X/FLUENDO PLUS LNX
The valve gas is equiped with safety gas valve and a motor for the coil of the regulation of the principal main
valve..
LEGEND
4
1 Safety solenoid valve
2 Motor and coil
3 Membrane for principal valve
4 Gas valve
11
22
Page. 29 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Solenoid Motor (rep 20) and solenoid coil (rep 21) Gas diaphragm rep 7
Page. 30 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
The valve is equiped with water valve, gas valve, interstage valve,microswitch,
Page. 31 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 32 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
To access the paramters simultaneously press the “-” and “+” buttons for 3 seconds, the display will show
“PA”.
To select the other parameters press “+”button.
To access to the parameters press “on/off” button, the display will show the valve of the parameter.
To modify the valve press the “-” and “+” buttons. To save the new values press “on/off” button.
Page. 33 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 34 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
2. Unscrew the screw “a” and insert the manometer connection pipe into the pipe tap
3. Open the gas valve
4. Press “on/off” button the display will show
5. Press “+” and “-” buttons for 3 seconds, display shows ”PA”
6. Press “+” button, to select ”Pd”. Open sanitary hot water tap
7. Press the “on/off” button to access to the “Pd”, appliance is forced to run at max power
8. On the manometer verify the pressure and if necessary by “+” or”-” to adjust as indicated in the gas
setting table
9. Press the on/off button to exit from the parameter Pd. Close water tap
Page. 35 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Switch
Gas 4 5
Gas nat
11L G30 OFF ON
G31
Gas nat
14L G30 ON OFF
G31
Page. 36 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
6 7 8
Note: The setting of gas/model should be done before assembled the battery, make sure the knob is on the
open position. Any change in the working mode is useless.
To change the model should re-charge the battery and wait for 10 seconds.
Switch
2 3
Min power OFF OFF
Max power ON OFF
Ignition
ON/OFF ON
power
To enter on the setting model, switch 1 must be on the “ON” position while the battery is not assemble, then
charge the batteries.(Orange Led blink means in the parameters setting model)
During the max/min power adjustment, max/min setting should be in sequence, any reset has to be re-run
the setting model.
Ignition setting has the first priority (when switch 3 is in the “ON” position, no matter the other switch in which
position, the setting model is always in ignition power.
Only after finished the ignition setting, set the switch 1/3 in OFF, save the setting, the machine can go to the
other mode)
Page. 37 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 38 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 39 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
To removed the gas diaphragm, and change the appliance to natural gas to GPL (or reverse), you must do:
Change the manifold and diaphragm gas.
Set the micro switchs on the main PCB (see table) for FAST EVO X or set on display the “PA” for
FAST EVO X DISPLAY.
Check the minimum and maximum burner pressure.
Unscrew the 2 screws that hold the gas valve on the chassis
Unscrew the 2 screws that hold the injector collector
Page. 40 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 41 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
4.3.3.2 Checking the maximum pressure (see the Gas setting table)
1. Close the gas valve
2. Loosen screw “b” and insert the manometer connection pipe into the pipe tap.
3. Open the gas valve
4. Open one hot water tap.
5. Turn the knob 1 on MAX position, (Appliance forced to maximum power). Turn the knob 3 turn in central
position.
Page. 42 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
6. Check the maximum burner pressure. The pressure should correspond to the value established
in relation to the type of gas for which the appliance is
MAXIMUM BURNER PRESSURE (mbar)
designed.
G20 G30 G31
11 L 11,4 24,8 31,8
14 L 13,4 27,2 31,3
To removed the gas diaphragm, and change the appliance to natural gas to GPL (or reverse), you must do:
Change the manifold and diaphragm gas.
Check the minimum and maximum burner pressure.
Page. 43 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 44 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
4.4 BURNER
The low NOx emission is realized by the low NOx burner, the inlet water go through the burner blades result
to cooling down the burner, thus a lower flame temperature is approached.
The burner is different depending of the power of the appliance (see table below)
11lt 12 plates
14lt 14 plates
Page. 45 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
4.6 MANIFOLD
Page. 46 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
5 ELECTRIC CABLE
1 2
5
6
4
LEGEND
1. Ignition Electrode 5. Knob for the temperateur setting
2. Ionisation Electrode 6. Overheat temperature flue gas and water
3. Gas valve 7. NTC outlet sensor
4. Detection of water flow rate
Page. 47 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 48 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
8 1
3
2
LEGEND
1.Gas collector 5.Thermostat(85℃&140℃)
2.Battery 6.LED
3.Power switch 7.P.C.B
4.Gas water valve 8.Ignite pin &flame sensor pin
Page. 49 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
6 ERROR CODE
The Led on the control box who is green normally, turns red with an error code.
This led flash during the error code as follow :
LED CAUSES
Page. 50 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Double Flashing
T° sensor out
(x2)
Pressure
> 0,1 b
Correct
Wire
correct
batteries
OK
Page. 51 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Triple Flashing
No flame detected
(x3)
Insufficient
Check the static pressure gas
pressure gaz between Check the pressure
17 et 25 mb natural gas reducer of the installation
and 28 et 40 GPL
Gaz pressure
correct
Insufficient
Check the dunamic
pressure gas
pressure gaz between Check the pressure
17 et 25 mb natural reducer of the installation
gas and 28 et 40 GPL
Gaz pressure
correct
Problem on
the safety Repalce the
Check the
valve gas valve gas valve gaz
Safety valve
correct
Batteries not OK
Check the Replace the
battery batteries
Batteries OK
Page. 52 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Quadruple flashing
(x4) Problem on the gas valve
Problem on the
gas valve
Check the Replace the gas
gas valve valve gaz
Gas valve
correct
Gas valve
OK
Diaphragm not
correct Put in place the one of the
Check the
diaphragm gas instruction booklet
Diaphragm
correct
Batteries not OK
Check the Replace the
batteries batteries
Batteries
OK
Page. 53 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Quintuple flashing
Fume temperature too hight
(x5)
Gas pressure
Check the dynamic too hight
pressure gaz between Set the pressure reducer of
17 et 25 mb natural the installation
gas and 28 et 40 GPL
Gas pressure
correct
Check the maxi power Bad setting Set the gas valve following
of the appliance the instruction booklet
Correct setting
Page. 54 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Flashing
Low voltage
Change batteries
6.2.2 No ignition
No ignition
Water
pressure
normal
Switch
on
batteries
OK
thermos
tat OK
Page. 55 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Insufficient
Check inlet gas type pressure gas or
not correct gas Check the gas type and
and pressure pressure reducer of the
installation
Electrode
ignition / flame
Electrode ignition / detection not REPLACE Electrode
flame detection OK ignition / flame detection
Electrode ignition /
flame detection
OK
Overheating
Overheating thermostat Decrease gas inlet or
thermostat work incerase water inlet
valve
Overheating
thermostat not
work
Fume safety
Fume safety sensor work Check fume system is
sensor fluent
Batteries OK
Page. 56 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Check the
Pressure < 0,1 b Increased the pressure
water
pressure P > 0,1 b
Pressure
> 0,1 b
Correct
Wire
correct
batteries
OK
Page. 57 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Insufficient
Check the static pressure gas
pressure gaz between Check the pressure
17 et 25 mb natural gas reducer of the installation
and 28 et 40 GPL
Gaz pressure
correct
Insufficient
Check the dunamic
pressure gas
pressure gaz between Check the pressure
17 et 25 mb natural reducer of the installation
gas and 28 et 40 GPL
Gaz pressure
correct
Problem on
the safety Repalce the
Check the
valve gas valve gaz
valve gas
Safety valve
correct
Ignition proble
Check the set simple Replace and put the new
ignition and electrode with 2 pin
ionisation probe
Electrode with 2
pin
Check the
position
Batteries OK
Page. 58 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Problem on the
gas valve
Check the Replace the gas
gas valve valve gaz
Gas valve
correct
Gas valve
OK
Diaphragm not
correct Put in place the one of the
Check the
diaphragm gas instruction booklet
Diaphragm
correct
Batteries not OK
Check the Replace the
batteries batteries
Batteries
OK
Page. 59 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
6.3.4 E5 (overheat)
E5 Overheat
Gas pressure
Check the dynamic too hight
pressure gaz between Set the pressure reducer of
17 et 25 mb natural the installation
gas and 28 et 40 GPL
Gas pressure
correct
Check the maxi power Bad setting Set the gas valve following
of the appliance the instruction booklet
Correct setting
Page. 60 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
7 TECHNICAL SPECIFICATION
Page. 61 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 62 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 63 di 64
Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 64 di 64