GENERAL NOTES: THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL RELEVANT GENERAL SPECIFICATIONS & NOTES:
STRUCTURAL AND ALL OTHER CONSULTANTS DRAWINGS/DETAILS AND STORMWATER:
1
DO NOT SCALE DRAWINGS, USE WRITTEN DIMENSIONS ONLY. WITH ANY OTHER WRITTEN INSTRUCTIONS ISSUED IN THE COURSE OF THE 100 MM U.P.V.C. STORMWATER LINE LAID TO A MINIMUM GRADE OF 1:100.
SAFETY GLAZING
CONTRACT. CONNECTED TO THE LEGAL POINT OF STORMWATER DISCHARGE. COVER
TO BE USED IN THE FOLLOWING CASES:
ALL MATERIALS AND WORK PRACTICES SHALL COMPLY WITH, BUT NOT TO BE:
(I) ALL ROOMS - WITHIN 500MM VERTICAL OF FLOOR LEVEL
LIMITED TO THE BUILDING REGULATIONS 2006, CURRENT BUILDING CODE REFER ENGINEERS DRAWINGS FOR LOCATION OF ALL STRUCTURAL AND - 300 MM UNDER CONCRETE, AND 450 MM ELSEWHERE.
(II) BATHROOM - WITHIN 2000MM HORIZONTAL ABOVE FINISHED FLOOR
OF AUSTRALIA AND ALL RELEVANT CURRENT AUSTRALIAN STANDARDS (AS CIVIL DETAILS.
LINE.
AMENDED) REFERRED TO THEREIN. SURFACE WATER DRAINAGE:
- WITHIN 1500MM VERTICAL FROM BATH BASE
FIGURED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. THE EXTERNAL FINISHED SURFACE SURROUNDING THE SLAB MUST BE
- WITHIN 500MM HORIZONTAL FROM BATH/SHOWER
ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH A.S.1684 FOR NON DRAINED TO MOVE SURFACE WATER AWAY FROM THE CLASS 1 BUILDINGS
- TO SHOWER DOORS, SHOWER SCREENS AND BATH ENCLOSURES.
CYCLONIC AREAS & ALSO IN ACCORDANCE WITH STRUCTURAL ENGINEERS THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE AND GRADED TO GIVE A SLOPE OF NOT LESS THAN:
(III) LAUNDRY - WITHIN 1200MM VERTICAL FROM
2
DRAWINGS. STABILITY AND GENERAL WATER TIGHTNESS OF ALL NEW AND/OR - 25 MM OVER THE FIRST 1 M FROM THE BUILDING IN LOW RAINFALL
FLOOR LEVEL AND/OR
EXISTING STRUCTURES DURING ALL WORKS. INTENSITY AREAS;
- WITHIN 300MM VERTICAL OF TROUGH
GLAZING INCLUDING SAFETY GLAZING SHALL BE INSTALLED TO A SIZE, - 50 MM OVER THE FIRST 1 M FROM THE BUILDING IN ANY OTHER
(IV) DOORWAY - WITHIN 300MM HORIZONTAL FROM ALL DOORS
TYPE AND THICKNESS SO AS TO COMPLY WITH: SMOKE ALARMS TO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH CASE.
(V) ENSUITE - AS FOR (II) REFER TO NCC VOL. 2 PART 3.6.
- BCA PART 3.6 FOR CLASS 1 AND 10 BUILDINGS WITHIN A DESIGN AS. 3786 AND UNLESS INSTALLED IN AN EXISTING PART OF A CLASS 1, 2 OR
WIND SPEED OF NOT MORE THAN N3, AND 3 BUILDING OR A CLASS 4 PART OF BUILDING.THE SMOKE ALARM SHALL BE ALL NEW FOOTINGS TO BE FOUNDED ON FIRM NATURAL UNDISTURBED
STAIR CONSTRUCTION AS FOLLOWS:
- BCA PART B1.4 FOR CLASS 2 TO 9 BUILDINGS. HARD WIRED WITH BATTERY BACKUP. MATERIAL WITH A MINIMUM 100 KPA ALLOWANCE BEARING CAPACITY AND/
- TREADS (GOING) SHALL BE 240-355MM WIDE.
OR AS REQUIRED BY THE ENGINEER (REFER COMPUTATIONS), AND SOIL
- RISERS SHALL BE 115-190MM HIGH.
GLAZING AND ALL WINDOWS TO BE USED TO COMPLY WITH AS1288 THE BUILDER AND SUBCONTRACTORS SHALL CHECK AND VERIFY ALL REPORT.
- GOING RELATIONSHIP SHALL BE 2R+G
3 SECTION 6; AS2047 AND BCA. DIMENSIONS, SETBACKS, LEVELS AND SPECIFICATIONS AND ALL OTHER
- STAIR FLIGHT HANDRAIL HEIGHT SHALL BE 865 MM MINIMUM.
RELEVANT DOCUMENTATION PRIOR TO THE COMMENCEMENT OF ANY DESIGN GUST WIND SPEED:
- LANDING HANDRAIL HEIGHT SHALL BE 1000 MM MINIMUM.
WATERPROOFING OF WET AREAS, BEING BATHROOMS, SHOWERS, WORKS. REPORT ALL DISCREPANCIES TO THIS OFFICE FOR BUILDING TIE DOWNS TO BE PROVIDED IN ACCORDANCE WITH AS
- SPACING OF RAILS TO HANDRAILS & BALUSTRADE NOT TO EXCEED
SHOWER ROOMS, LAUNDRIES, SANITARY COMPARTMENTS AND THE LIKE CLARIFICATION. 1684-1992 FOR AN ASSUMED DESIGN GUST WIND SPEED OF 33 METERS
125 MM.
SHALL BE PROVIDED IN ACCORDANCE WITH AS 3740: WATERPROOFING OF PER SECOND (SUBJECT TO CONFIRMATION ON SITE BY RELEVANT
WET AREAS IN RESIDENTIAL BUILDINGS. BUILDING SURVEYOR AT FIRST INSPECTION) REFER TO AS 1684 FOR
IMPORTANT SUB NOTE:
CONSTRUCTION REQUIREMENTS.
NATIONAL CONSTRUCTION CODE & THE BUILDER/ SUB-CONTRACTOR AND CLIENT TO ENSURE CHECK
IMPERVIOUS FINISHES AS PER PART 3.8.1 OF THE BCA I.E. CERAMIC TILES MEASURES ARE CARRIED OUT PRIOR TO COMMENCEMENT AND ORDERING
A MINIMUM 150MM ABOVE BATH ,SPA,VANITIES ETC. AND A MINIMUM 1800 AUSTRALIAN STANDARDS OF ANY WORK ON SITE TO CONFIRM SATISFACTION OF STAIR LOCATION
THE BUILDER AND SUB-CONTRACTOR SHALL ENSURE ALL NEW WORKS TO
MM ABOVE SHOWER BASE WITH AN APPROVED SUB STRATUM UNDER BE WATER-TIGHT.
4 AND THAT HEAD CLEARANCES ARE ACHIEVABLE, THE STARTING OF ANY
SHALL BE PROVIDED TO ALL WET AREAS. TERMITE TREATMENT: WORKS WHAT SO EVER WILL BE DEEMED AS ACCEPTANCE OF
AREA BENEATH BUILDINGS SHALL BE TREATED AGAINST TERMITE THE RAINWATER TANK MUST BE CONNECTED TO ALL SANITARY FLUSHING
ARCHITECTURAL DOCUMENTATION AND THEREFORE NO LIABILITY WILL BE
THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ANY HOUSE INFESTATION, IF REQUIRED SHALL CONFORM TO NCC VOL. 2, PART 3.1.3. SYSTEMS IN ACCORDANCE WITH BCA CLAUSE 3.12. CONFIRM THE
ACCEPTED BY DESIGNER / DRAFTSPERSON FOR ANY ERRORS AND/OR
ENERGY RATING (HER) REPORT AND SHALL BE CONSTRUCTED IN CAPTURE OF RAINWATER TANKS.
OMISSIONS.
ACCORDANCE WITH THE STAMPED PLANS ENDORSED BY THE CONCRETE:
ACCREDITED THERMAL PERFORMANCE ASSESSOR WITHOUT ALTERATION. ALL CONCRETE SHALL COMPLY WITH AS2870 - LATEST EDITION AND SHALL WALLS BETWEEN THE UNITS Rw + Ctr - NOT LESS THAN 50 AND THE PARTY
THERMAL INSULATION TO BE PROVIDED AS FOLLOWS, UNLESS
BE MINIMUM N 20 UNLESS OTHERWISE SPECIFIED BY ENGINEER. WALLS REQUIRED TO BE DISCONTINUOUS WALL CONSTRUCTION WHERE A
OTHERWISE NOTED IN ENERGY RATING REPORT:
ALL INTERNAL AND EXTERNAL STEPS SHALL BE A MIN. OF 250MM WIDE KITCHEN, BATHROOM, LAUNDRY OR TOILET BOUNDS A HABITABLE ROOM IN
FOR TIMBER FLOOR CONSTRUCTION WITH NO PERIMETER BASE
WITH A MAX. RISER OF 190MM HIGH. BRICKWORK: AN ADJACENT UNIT.
5
BRICKWORK:
ALL BRICKWORK SHALL COMPLY WITH NCC VOL. 2, PART 3.3./ AS3700. - R2.5 BULK INSULATION TO EXTERNAL WALLS AND R4 BULK
ALL TREADS, LANDINGS AND THE LIKE TO HAVE NON SLIP FINISH OR DOWNPIPES MUST NOT SERVE MORE THAN 12M OF GUTTER LENGTH FOR
INSULATIONS TO CEILING. FOR TIMBER FLOOR CONSTRUCTION
SUITABLE NON-SKID STRIP NEAR EDGE OF NOSING. TIMBER: EACH DOWNPIPE & WITHIN 1.2M OF VALLEY IN ACCORDANCE WITH BCA
WITH PERIMETER BASE BRICKWORK:
FRAMING TIMBER TO COMPLY WITH AS1684 "NATIONAL TIMBER FRAMING PART 3.5.2
- R1.3 D.S. SISALATION TO EXTERNAL WALLS AND R4 BULK
PROVIDE SLIP RESISTANCE SURFACE OR EDGE STRIP (P3 DRY) AND (P4 CODE" - LATEST EDITION. INSULATIONS TO CEILING. FOR SLAB FLOOR CONSTRUCTION:
WET) TO TREADS OF STAIRS. PROVIDE LIFT OFF HINGES TO SANITARY COMPARTMENT DOORS WHEN
- R1.3 D.S. SISALATION TO EXTERNAL WALLS AND R4 BULK
STEEL: OPENING INWARDS WITH 1200mm OF A TOILET PAN.
INSULATIONS TO CEILING. NOTE: SISALATION TO HAVE A
PROVIDE BALUSTRADES WHERE CHANGE IN LEVEL EXCEEDS 1000MM STRUCTURAL STEEL SHALL COMPLY WITH THE REQUIREMENTS OF AS 4100 FLAMMABILITY INDEX NOT EXCEEDING 5. PROVIDE SOLAR POWERED HOTWATER SERVING TO EACH DWELLING
ABOVE THE SURFACE BENEATH LANDINGS, RAMPS AND/OR TREADS. "STEEL STRUCTURES" - LATEST EDITION. REFER NCC VOL. 2 PART 3.12.1. WITH A MINIMUM 60% SOLAR GAIN.
6 BALUSTRADES (OTHER THAN TENSIONED WIRE BALUSTRADES) TO BE:
-1000MM MIN. ABOVE FINISHED SURFACE LEVEL OF BALCONIES, LANDINGS NATURAL LIGHTING: ALL EXHAUST VENTS MUST DISCHARGE DIRECTLY TO THE OUTSIDE AIR SOIL CLASSIFICATION ASSUMED ( CLASS ' P ' )
OR THE LIKE, AND NATURAL LIGHTING TO BE IN ACCORDANCE WITH NCC VOL. 2 PART 3.6. AND ARE TO SEAL WHEN NOT IN USE. AS PER SOIL REPORT No: ST- 39575
-865MM MIN. ABOVE FINISHED SURFACE LEVEL OF STAIR NOSING OR RAMP,
BY GEOCORE P/L
AND VENTILATION: RECESSED DOWN LIGHTS SHALL BE OF A TYPE SUITABLE FOR THERMAL
- VERTICAL WITH LESS THAN 125MM GAP BETWEEN, AND ALL VENTILATION SHALL CONFORM TO THE REQUIREMENTS OF NCC VOL. 2 INSULATION TO ABUT AND COVER. APPROVED IC-4 TYPE DOWN LIGHTS
- ANY HORIZONTAL ELEMENT WITHIN THE BALUSTRADE BETWEEN PART 3.8.5. WHICH ALLOW NO AIR TRANSFER ARE TO BE USED.
150MM AND 760MM ABOVE THE FLOOR MUST NOT FACILITATE
CLIMBING WHERE CHANGES IN LEVEL EXCEEDS 4000MM ABOVE THE IMPERVIOUS COVERINGS - WET AREAS: ALL STUMPS EXCEEDING 1000MM ABOVE THE GROUND TO BE
7 SURFACE BENEATH LANDINGS, RAMPS AND/OR TREADS. COMPLIANCE WITH AS 3740-2010 & PROVIDE IMPERVIOUS FLOOR TO ALL ADEQUATELY BRACED.
WET AREAS IN ACCORDANCE WITH NCC VOL. 2 PART 3.8.1.5.
HAND RAILS TO BE 865MM MINIMUM ABOVE STAIR NOSING AND LANDINGS. PROVIDE MINIMUM CLEARANCE TO UNDERSIDE OF BEARERS IN TIMBER
EXPOSED METAL : FLOORS AS FOLLOWS:
WINDOW SIZES NOMINATED ARE NOMINAL ONLY. ACTUAL SIZE MAY VARY ALL EXPOSED METAL WORK TO BE EMBEDDED IN OR SUPPORTING - 200 MM MINIMUM FOR PARTICLE BOARD FLOORING;
ACCORDING TO MANUFACTURER. WINDOWS TO BE FLASHED ALL AROUND. BRICKWORK TO BE IN ACCORDANCE WITH NCC VOL. 2 TABLE 3.4.4.2. - 150 MM MINIMUM FOR STRIP FLOORING. UNLESS OTHERWISE
REQUIRED BY LOCAL AUTHORITIES REGULATIONS AND/OR SOIL
PROVIDE BULK INSULATION TO NEW CEILING: R2.5 NEW EXTERNAL WALL: SUB-FLOOR VENTILATION: REPORT.
R1.5 PROVIDE SUB FLOOR VENTS AT 1500MM MAXIMUM CENTERS IN
ACCORDANCE WITH NCC VOL. 2 TABLE 3.4.1.2. TO BRICK VENEER AND SMOKE DETECTORS TO BE PROVIDED WHERE SHOWN ON FLOOR PLAN &
8
ALL CONCRETE SHALL COMPLY WITH AS3600 CONCRETE STRUCTURES SOLID BRICK CONSTRUCTION & PART 3.4.1.2. FOR TIMBER SUB FLOOR BE CONNECTED TO THE SWITCHBOARD. THE SMOKE DETECTORS TO BE
CODE AND SHALL BE MINIMUM 20MPa UNLESS NOTED OTHERWISE. VENTILATION. FITTED WITH 'EMERGENCY' BATTERY BACK-UP UNIT.

WHERE THE BUILDING (EXCLUDES A DETACHED CLASS 10) IS LOCATED IN DAMP-PROOF MEMBRANE: ARTICULATION JOINTS (CONTROL JOINTS) AS FOLLOWS: TO BRICKWORK
A TERMITE PRONE AREA , THE AREA TO UNDERSIDE OF BUILDING AND PROVIDE DAMP-PROOF MEMBRANE TO BE IN ACCORDANCE WITH AS 2870. BETWEEN NEW AND EXISTING WORK, AND AT 6M MAXIMUM CENTRES. AT
PERIMETER IS TO BE TREATED AGAINST TERMITE ATTACK. SIDES OF OPENINGS AND 6M MAXIMUM CENTRES IN THE CASE OF NEW
GUTTERS AND DOWNPIPES: DWELLINGS. REFER PLAN AND/ OR ELEVATIONS, UNLESS NOTED
ALL STORMWATER TO BE TAKEN TO THE LEGAL POINT OF DISCHARGE TO GUTTERS AND DOWNPIPES TO BE IN ACCORDANCE WITH AS 3500.3 AND OTHERWISE IN ENGINEERS COMPUTATIONS.
THE RELEVANT AUTHORITIES APPROVAL. NCC VOL. 2 PART 3.5.2.
9
PROPOSED UNIT DEVELOPMENT
© COPYRIGHT
THIS DRAWING REMAINS THE
REVISIONS: A
PROPERTY OF RENOCO HOMES. DATE DESCRIPTION DATE: 22/09/2020
FOR : MS. XUELIN WANG DO NOT PRODUCE UNLAWFULLY. A 22/09/20 AS PER SECONDARY CONSENT DRAWN: M. Z / R. F
SCALES: AS SHOWN
AT : 27 DUNOON STRET, DO NOT SCALE DRAWINGS.

DONCASTER. VIC 3108


USE FIGURED DIMENSIONS ONLY.
WD 01
A B C D E F G H I J K L

63
T
9765
USG83.17

/ /
/ / / / / / / / / / / / / / / /

/
/

/
/
/ /

/
/

/
/

/
/

/
/

/
/

/
/

/
/
/ /

/
/

/
/

/
/

/
/

/
/

/
/

/
/
/
/

/
/
/
/

/
/ /

/ /
/
/

/
/
/
/

/
POS

/
/

/
/
/
/

/
/ /

/ /
5430 2555 2555 5835 G.I.1500

/
/

/
/

1500
/
/

/
/
/

/ /
/
/

/
/

NOTE: ( DRAINAGE)

82m

/ /

/ /
/
/

/
/
/

19.18 SHED

0.09
/

/
91°21' CONCRETE PATH &

/
/
/

/ /
0.06
/
/

/
/

83m

/ /

/ /
/
/

/
/
/

/ /
/

LANDSCAPE

/
1

/
/

/ /
/
/

/
/

/ /

/ /
230

/
/

/
/
/
/

/
/TIMBER PALING FENCE

/
/

/ /
/
/

/ / / / BUILDER TO CONNECT NEW D.P'S INTO EXISTING

/
/

TIMBER PALING FENCE / / / / / / / / / / / / / / / / / / / / /

/ /

/ /
/ / / / / / / /

/
/

/
/

/ / / / / / / / / / / /

/
/

/
/

/
/ / / / / / / / / /

/
/

/
/

/
/

/
/
/

/
/
/

/
/

/
/

/
/

/
/

/
/ / / / / / / / / / / /

8
83 9515 9860 S.W.D. USING 90MM DIA U.P.V.C. PIPES WITH MINIMUM

.4
3
EXISTING .3

.4
0.19

81
6 2.44m EASEMENT

82

/ /
TREE 1
1:100 FALL AND CONNECT TO THE EXISTING HOUSE

/ /

(2.44)
(2.44)
TPZ H. 5m 0.18 SELECTED TIMBER
MAX' 700mm HIGH

1401
W. 4m
RETAINING WALL
PALING FENCE - 150 dia. VC SEWER SYSTEM.
1.8m HIGH
2400 1140mm OFFSET

/ /
/ /
USG86.39
0.19 CANOPY 2470mm APPROX' DEPTH BUILDER TO CHECK CAPACITY AND FUNCTIONING OF
TREE

7503

7494
G.I.

7893
CANOPY THE EXISTING STORM WATER SYSTEM PRIOR TO

3000
8503
/ / / / / / / / /

/
/

/
/

/ /
/
/ / /

/
/

/
/

/
/

/
/
/ /

/
/

/
/

/
/
/

/
/
/

STORAGE TREE
/

/
/
/

8893
/
/

/ /
E88.84 8494
/

/
/

/ /
/
/

POS CONNECTING NEW DOWN PIPES.


/

/
/
/
/
/

/
/
/

/
/

G.I.
/
/

STORAGE

/
/

/ /
/
/

9993
/

/
/
/
/
/

/
/
SHED
/

/
/
/
/

/
/

/ /
/
/

LAWN &
/

/
/
/

10993
/
/

/
UPPER

/
/

/
/

2
/
/

/
/

500 LANDSCAPE

/ /
/
/

/
/

/ /
/
/

STOREY S.P.O.S
/

NOTE:
/

/
/
/

/
/
/

/ /
/

/
/

/ /
/
/

R90.24

/
/ /

RETRACTABLE
/
/
/

/
/
/

/
/

93m²
/ / / / / / / / / / /

/
/

/
/
/
/ / / / / /

/
/

/
/

/
7335

/
/

/
/
CLOTHES LINE
RETRACTABLE LOCATION OF LEGAL POINT OF DISCHARGE TO BE

MAX' 850mm HIGH


RETAINING WALL
0.19 S.P.O.S CLOTHES LINE
CONFIRMED ON SITE.

/ /
G.I. EF.10.03
99m²

/ /
DP EXISTING
RWT
EF.10.03
TREE 4 BUILDER TO ENSURE THAT STORM WATER IS
1500

USG86.38
H88.84

/ /
DP
H. 8m

/ /
CONNECTED TO A LAWFUL DISCHARGE POINT,

HW

2490
NHW
FFL- 82040 W. 4m
7144 ADEQUATE & IN GOOD WORKING ORDER PRIOR TO
2686 FFL- 82480 CONNECTING DRAINAGE PIPES FOR THE NEW

/ /
83 / /
DOOR

3
.2

23
DOUBLE STOREY CONCRETE
TPZ
ADDITIONS.

00
RENDERED

6
NHW
3 LANDING

.3
DWELLING

81
/ /
/ /
E86.86 BUILDING CONTRACTOR TO ENSURE THAT ANY

.63
H82 W
SEWER / STORM WATER ETC., PIPE LOCATIONS ON &
H86.42

H
HW

TPZ

No:1

/ /
6175 AROUND THE SUBJECT SITE, ARE ESTABLISHED

/ /
EXISTING UNIT 1 PRIOR TO THE COMMENCEMENT OF WORKS.

9880
EXISTING
TREE 2 DP
10196
UNIT 2 FFL 82090 TREE 5

/ /
H. 5m 0.31 4759

/ /
9880
H. 5m

83m
W. 5m DP
FFL 82530
W. 4m
2600 0.29

.14
OF
1117

. RO
CONCRETE DRIVEWAY TERMITE PROTECTION REQUIRED CONSTRUCTION

P83
20
0.03 TPZ
E86.87

/ /
TPZ

.I
00

TG
TO
4 TO COMPLY WITH A.S. 3660.1 - 2000

FLA
181°21' 42.37
EXISTING

/ 22/00

PROPOSED NEW 1.8m HIGH TIMBER PALING FENCE


TREE 3
H. 4m POS

.69
H82 W
2
BRICK

.7
W. 4m 2925

H
82
PAVING
1°37' 42.37

NOTE: ( CONSTRUCTION )
/ /
H86.87
HW

3100
0
340
PROPOSED NEW 1.8m HIGH TIMBER PALING FENCE

UP
FFL 81550
R89.24

2750

AH
NEW DOWNPIPES TO BE CONNECTED TO EXISTING

W
3100

NH
1425 1500

ND
EXISTING
/ /

S.W.D. RUN VIA. 100 DIA. UPVC PIPE DRAINS AT 1:100

RA
1500 1250 FFL- 82150 TREE 6

POSITION APPROXIMATE ONLY


END OF FENCE INACCESSIBLE

W
VE
H. 6m MIN GRADE TO LOCAL AUTHORITY GUIDELINES.

NH

R
/ /

W. 5m
MAX' 750mm HIGH

O
RETAINING WALL

DO
H86.87

MAINTAIN 300mm MINIMUM COVER INSPECTION


HW

.69
H82 W
SINGLE STOREY

H
WEATHERBOARD OPENINGS @ 9 M MAX' CTS. & AT CHANGE OF
/ /

TPZ DWELLING
DIRECTION CONNECT TO LEGAL POINT OF DISCHARGE

.69
HW NHW DOOR NHW

H82 W
H
SINGLE STOREY 6019
RENDERED
/ /

TPZ
DWELLING
UNIT 1

9750
CONCRETE
LANDING & STEPS
UNIT 2 GARAGE

.28
9750

SITE AREA ANALYSIS:


/ /

FFL 81200 EXISTING

R85
7
.2

/ /
81
GARAGE TREE 7
H86.87

FFL 82000 H. 6m
SITE AREA:
R89.17

/ /

W. 3m

.89
6

/ 20/0

E82
TOTAL BUILDING COVERAGE: (34.51 SQ'S) (39.29%)

0
CAR PORT
USG85.39

FFL 81550 GARDEN AREA: (40.15%)

FENCE
1170
/ /

DP

/ /
TPZ FFL- 82150 ENTRY PERMEABILITY: (38.81 SQ'S) (44.19%)
1904

1000
FENCE
/ /

DP
H86.87

7285 81m
HW

ENTRY
/ /

1500
2900
1000

DEVELOPMENT SUMMARY AREA

/ /
SENOR LIGHT ABOVE
80
1

GARAGE DOOR
UP
.5

SENOR LIGHT ABOVE


.9
0
82

EXISTING
GARAGE DOOR
FFL 81400
/ /

8076 7030
PROVIDE 1.8m NEW TIMBER FENCE TREE 9 500
1500 G
UNIT 1
/ /

UP
H. 7m FFL- 82000 UP P.O.S
EAST WEST AND NORTH BOUNDARIES

/ /
W. 3m
TIMBER PALING FENCE

P.O.S TPZ
1
.6

730 GROUND FLOOR INC GARAGE


81
/ /

EAST AND WEST FENCE 1.0m HIGH FOR EXISTING


MAX' 750mm HIGH
RETAINING WALL

8
UP
FIRST FLOOR(68.21%)
.6
5
/ /

7
No 252 / LOT 74
.9 9579

.6

80
TREE 10
80

A DISTANCE OF 2.5m FROM FRONT BOUNDARY


1:11 RAMP UP

H. 4m TOTAL
1:8 RAMP UP

CANOPY 0.06 2.0mx2.5m SPLAY (Typ)


4
/ /

8579

6
TREE NO OBJECTS OR VEGETATION
8640

W. 3m POST

.3
80
CONCRETE

200

7837
80 TO EXCEED 900mm IN HEIGHT IN
DRIVEWAY

/ /

GARDEN & 0 P.O.S P.O.S


6331

7640
7629

SPLAY AREA (Typ)


7319

TPZ
LANDSCAPE S.P.O.S
TPZ EXISTING LAWN &
/ /

TREE 11 3.0m WIDE DRIVEWAY 3000 LANDSCAPE


/ /

2.0mx2.5m SPLAY (Typ)


80 EXISTING UNIT 2
H. 6m 35.12m² .6
NO OBJECTS OR VEGETATION 8 TREE 8
5

3.0m WIDE DRIVEWAY GROUND FLOOR INC GARAGE


.2

TO EXCEED 900mm IN HEIGHT IN W. 5m CANOPY 28.45m²


81

0
/ /

SPLAY AREA (Typ) 0.22 TREE H. 6m 540 FIRST FLOOR(71.66%)


3600

3000 LETTERBOX 79
/ /

G
.9

LETTERBOX W. 6m
W .9
81

8 ROCK RETAINING WALL TOTAL


TIMBER SLEEPERS NOT FENCED 80m
m
82

80m
0 2

271°21' 19.38
.5 1.6

81m

5
8 P.O.S
2

.0
.5
2

CONCRETE PATH
81 8
2

.9

78
79
.0

6
79

CONCRETE PATH 1.8 S.P.O.S


2

.8

.4
6
83

NOTE:
.7
.0

79

79

1000
81
82

INDICATES REDUCED LOWER


NEW LEVEL TO AAHD 399

4
.0
4
0

CONCRETE
.4
8

78
.0

3
.9

81

.7

NOTE:
.3
83

81

79
5
6

CONCRETE
79

X-OVER ALL LEVELS ARE APPROX AND CONCRETE


.2
.5

81
81

CROSSING CROSSING
PROPOSED SITE PLAN - LOWER FLOOR
9

TO BE VERIFIED PRIOR TO CONSTRUCTION


7
2

.7

CONCRETE
.1
.4

SE
.0

79

79
81
82

3000 3000
CONCRETE KERB
CONCRETE KERB TBM
8I K

6I K
DUNOON STREET
.6 1T

IK
9I K

.7 9T
K

RIVET IN PATH
1:100 @ A1

K
.0 3T
82 2.8

77 7.8
K

.1

RL 81.20
81 1.2
8

79

7
8

1500 5530 2455 2605 5785 1500

9 NOTE: ( LANDSCAPING ) NOTE: ( DRAINAGE DESIGN ) NOTE: ( CONSTRUCTION ) PROPOSED UNIT DEVELOPMENT
© COPYRIGHT
THIS DRAWING REMAINS THE
REVISIONS: A
PROPERTY OF RENOCO HOMES. DATE DESCRIPTION DATE: 22/09/2020
REFER TO LANDSCAPING PLAN FOR TREES TO REMAIN & FOR NEW REFER TO DRAINAGE ENGINEER'S DESIGN & SPECIFICATIONS FOR REFER TO ENGINEER'S DESIGN AND SPECIFICATIONS FOR FOR : MS. XUELIN WANG DO NOT PRODUCE UNLAWFULLY. A 22/09/20 AS PER SECONDARY CONSENT DRAWN: M. Z / R. F
PLANTING AS PER LANDSCAPE ARCHITECT'S DOCUMENTATION & DOWNPIPE LOCATIONS, STORM WATER DISCHARGE, PAVING & ADDITIONAL STRUCTURAL BEAMS, BEAM LOCATIONS, FRAMING
SCALES: AS SHOWN
SPECIFICATIONS DRIVEWAY DESIGN & LEVELS AND FOOTING DESIGNS TO PROPOSED UNIT DEVELOPMENT AT : 27 DUNOON STRET, DO NOT SCALE DRAWINGS.

DONCASTER. VIC 3108


USE FIGURED DIMENSIONS ONLY.
WD 02
A B C D E F G H I J K L

63
T
13040
USG83.17

/ /
/ / / / / / / / / / / / / / / /

/
/

/
/
/ /

/
/

/
/

/
/

/
/

/
/

/
/

/
/
/ /

/
/

/
/

/
/

/
/

/
/

/
/

/
/
/
/

/
/
/
/

/
/ /

/ /
/
/

/
/
/
/

/
POS

/
/

/
/
/
/

/
/ /

/ /
/
/

/
/
/
/

/
G.I.

/
/
/

/ /
/
/

/
/

NOTE: ( DRAINAGE)

/ /

/ /
/
/

/
/
/

91°21' 19.18
SHED

0.09
/

/
CONCRETE PATH &

/
/
/

/ /
0.06
/
/

/
/

/ /

/ /
/
/

/
/
/

/ /
/

LANDSCAPE

/
1

/
/

/ /
/
/

/
/

/ /

/ /
/
/

/
/
/
/

/
/TIMBER PALING FENCE

/
/

PROPOSED
/ / NEW/1.8m
/ HIGH
/ / TIMBER
/ / PALING
/ / FENCE

/ /
/
/

/ / / / BUILDER TO CONNECT NEW D.P'S INTO EXISTING

/
/

TIMBER PALING FENCE / / / / / / / / / / /

/ /

/ /
/ / / / / / / /

/
/

/
/

/ / / / / / / / / / / /

/
/

/
/

/
/ / / / / / / / / /

/
/

/
/

/
/

/
/
/

/
/
/

/
/

/
/

/
/

/
/

/
/ / / / / / / / / / / /

8
83 S.W.D. USING 90MM DIA U.P.V.C. PIPES WITH MINIMUM

.4
3
EXISTING TIMBER FENCE ABOVE RETAING
.3

.4
0.19

81
6 WALL TOTAL HEIGHT 1.8m

82

/ /
TREE 1
1:100 FALL AND CONNECT TO THE EXISTING HOUSE

/ /
2.44m EASEMENT

(2.44)
(2.44)
H. 5m 0.18
W. 4m SYSTEM.

/ /
/ /
USG86.39 CANOPY BUILDER TO CHECK CAPACITY AND FUNCTIONING OF
0.19
G.I. TREE
/ / / / / / / / /
730 CANOPY THE EXISTING STORM WATER SYSTEM PRIOR TO

/
/

/
/

/ /
/
/ / /

/
/

/
/

/
/

/
/
/ /

/
/

/
/

/
/
/

/
/
/

TREE
/

/
/
/

/
/
/

/ /
/

/
/

/ /
/
/

POS CONNECTING NEW DOWN PIPES.


/

/
/
/
/
/

/
/
/

/
G.I. 500
/
/
/

/
/

/ /
/
/

/
/
/
/
/

/
/
SHED
/

/
/
/
/

/
/

/ /
/
/

6930 LAWN &

E88.84
/

/
/

11853
/
/
/

/
UPPER

/
/

/
/

2
/
/

/
/

LANDSCAPE

/ /
/
/

/
/

/ /
/
/

STOREY
/

NOTE:
/

/
/
/

/
/
/

/ /
/

/
/

/ /
/
/

R90.24

/
/ /
/

7335
/

12851
/

/
/
/

/
/

/ / / / / / / / / / /

/
/

/
/
/
/ / / / / /

/
/

/
/

/
/
/

/
/
LOCATION OF LEGAL POINT OF DISCHARGE TO BE
0.19
CONFIRMED ON SITE.

/ /
G.I.
REFER TOO LANDSCAPE

/ /
1700 PLAN DRAWING NO: A0-5
FOR DETAIL EXISTING
4445 TREE 4
34842 BUILDER TO ENSURE THAT STORM WATER IS

USG86.38
H88.84

/ /
1500 H. 8m

/ /
CONNECTED TO A LAWFUL DISCHARGE POINT,

HW
NHW
W. 4m
7144 ADEQUATE & IN GOOD WORKING ORDER PRIOR TO
2686
CONNECTING DRAINAGE PIPES FOR THE NEW

/ /
7547 33597

83 / /
DOOR

3
.2
DOUBLE STOREY CONCRETE RwH
EF.7.20
ADDITIONS.
RENDERED

6
NHW
3 LANDING

.3
DWELLING

81
/ /
EF.7.20

/ /
E86.86
RwH
BUILDING CONTRACTOR TO ENSURE THAT ANY

.63
3350

H82 W
SEWER / STORM WATER ETC., PIPE LOCATIONS ON &
H86.42

H
4060
HW

/ /
AROUND THE SUBJECT SITE, ARE ESTABLISHED

/ /
2965
EXISTING 8020
FFL- 85030 PRIOR TO THE COMMENCEMENT OF WORKS.

4060
EXISTING
TREE 2
10196 TREE 5
FFL- 85230

/ /
H. 5m 0.31 4759

/ /
DP
(spreader) H. 5m
W. 5m
1900 6875
W. 4m
DP
(spreader)
0.29

.14
OF
. RO
CONCRETE DRIVEWAY TERMITE PROTECTION REQUIRED CONSTRUCTION

P83
0.03
E86.87

/ /

3885
EF.7.20

.I
TG
TO
4 TO COMPLY WITH A.S. 3660.1 - 2000

FLA
181°21' 42.37
EXISTING
3885

PROPOSED NEW 1.8m HIGH TIMBER PALING FENCE


TREE 3

/ /
H. 4m 2225
POS

.69
H82 W
2
BRICK

.7
W. 4m 1500

H
82
7889 8990 PAVING
1°37' 42.37

UNIT 1 NOTE: ( CONSTRUCTION )


/ /
H86.87

3005
HW

7296
PROPOSED NEW 1.8m HIGH TIMBER PALING FENCE

DP
(spreader)
FFL- 84850
10118
UNIT 2
R89.24

AH
2925 NEW DOWNPIPES TO BE CONNECTED TO EXISTING

W
NH
3005

DP

ND
EXISTING
/ /

4130
(spreader) FFL- 85050 S.W.D. RUN VIA. 100 DIA. UPVC PIPE DRAINS AT 1:100

RA
TREE 6

POSITION APPROXIMATE ONLY


END OF FENCE INACCESSIBLE
1500

W
VE
3260
9249 H. 6m MIN GRADE TO LOCAL AUTHORITY GUIDELINES.

NH

R
/ /

6426 W. 5m

O
5

DO
H86.87

EF.7.20
MAINTAIN 300mm MINIMUM COVER INSPECTION
HW

.69
3645

H82 W
SINGLE STOREY

4760

H
WEATHERBOARD OPENINGS @ 9 M MAX' CTS. & AT CHANGE OF
3525

/ /

7769 DWELLING
DIRECTION CONNECT TO LEGAL POINT OF DISCHARGE

.69
HW NHW DOOR NHW

H82 W
2120

H
SINGLE STOREY 6019
RENDERED DP EF.2.03
/ /

(spreader)
DWELLING DP
(spreader) 2525
CONCRETE
LANDING & STEPS

.28
SITE AREA ANALYSIS:
/ /

EXISTING

R85
7

2930
.2

/ /
4165

81
TREE 7
H86.87

6721 EF.2.03
H. 6m
SITE AREA: 817m²
R89.17

/ /

W. 3m

.89
6

/ /
DP
(spreader)

E82
TOTAL BUILDING COVERAGE: 321 m² (34.51 SQ'S) (39.29%)

1660
4195
CAR PORT
USG85.39

DP
(spreader) GARDEN AREA: 328 m² (40.15%)
/ /
1660

2120

/ /
RwH PERMEABILITY: 361m² (38.81 SQ'S) (44.19%)
10150 1904
/ /

H86.87
HW

1500
/ /

RwH EF.1.02
11840
DEVELOPMENT SUMMARY AREA

/ /
80
1

EF.2.03
.5

.9
0
82

EXISTING EF.1.02 EF.10.04


/ /

8076 1500
TREE 9 G EF.2.03
UNIT 1
/ /

H. 7m 3790

/ /
EF.10.04
W. 3m
TIMBER PALING FENCE

1
.6

GROUND FLOOR INC GARAGE 195 M²


81
/ /

EXISTING 7080

8
FIRST FLOOR(68.21%) 133 M²
.6
5
/ /

7
.6

No 252 / LOT 74
80
TREE 10
80
10250

H. 4m CANOPY TOTAL 328 M²


0.06
9210

4
/ /

6
TREE
.9

W. 3m POST 2.0mx2.5m SPLAY (Typ)


.3
80
CONCRETE

7837
80
DRIVEWAY

NO OBJECTS OR VEGETATION
/ /

GARDEN & P.O.S 219 M²


7629

TO EXCEED 900mm IN HIGHT IN


LANDSCAPE SPLAY AREA (Typ) S.P.O.S 93 M²
EXISTING LAWN &
/ /

2.0mx2.5m SPLAY (Typ) TREE 11 LANDSCAPE


/ /

NO OBJECTS OR VEGETATION 80 EXISTING UNIT 2


H. 6m .6
TO EXCEED 900mm IN HIGHT IN 8 TREE 8
5

SPLAY AREA (Typ) GROUND FLOOR INC GARAGE 187 M²


.2

W. 5m CANOPY
81
/ /

0.22 TREE LETTERBOX H. 6m


LETTERBOX FIRST FLOOR(71.66%) 134 M²
6

79
/ /

G
.9

W .9 W. 6m
81

NOT FENCED 8 ROCK RETAINING WALL TOTAL 326 M²


TIMBER SLEEPERS
0 2

271°21' 19.38
.5 1.6

5
8 P.O.S 215 M²
2

.0
.5
2

CONCRETE PATH
81 8
2

.9

78
79
.0

6
79

CONCRETE PATH S.P.O.S 99 M²


2

.8

.4
6
83

.7
.0

79

79
81
82

EXISTING

4
.0
4
0

.4
8

78
.0

TREE
.9

81

.7

.3
83

81

79
5
6

CONCRETE
79

CONCRETE
.2
.5

81
81

CROSSING CROSSING
FIRST FLOOR SET OUT PLAN
9
7
2

.7

CONCRETE
.1
.4

SE
.0

79

79
81
82

CONCRETE KERB
CONCRETE KERB TBM
8I K

6I K
DUNOON STREET
.6 1T

IK
9I K

.7 9T
K

RIVET IN PATH
1:100 @ A1

K
.0 3T
82 2.8

EXISTING

77 7.8
K

.1

RL 81.20
81 1.2
8

79

7
TREE
8

1670 11390 1670

9 NOTE: ( LANDSCAPING ) NOTE: ( DRAINAGE DESIGN ) NOTE: ( CONSTRUCTION ) PROPOSED UNIT DEVELOPMENT
© COPYRIGHT
THIS DRAWING REMAINS THE
REVISIONS: A
PROPERTY OF RENOCO HOMES. DATE DESCRIPTION DATE: 22/09/2020
REFER TO LANDSCAPING PLAN FOR TREES TO REMAIN & FOR NEW REFER TO DRAINAGE ENGINEER'S DESIGN & SPECIFICATIONS FOR REFER TO ENGINEER'S DESIGN AND SPECIFICATIONS FOR FOR : MS. XUELIN WANG DO NOT PRODUCE UNLAWFULLY. A 22/09/20 AS PER SECONDARY CONSENT DRAWN: M. Z / R. F
PLANTING AS PER LANDSCAPE ARCHITECT'S DOCUMENTATION & DOWNPIPE LOCATIONS, STORM WATER DISCHARGE, PAVING & ADDITIONAL STRUCTURAL BEAMS, BEAM LOCATIONS, FRAMING
SCALES: AS SHOWN
SPECIFICATIONS DRIVEWAY DESIGN & LEVELS AND FOOTING DESIGNS TO PROPOSED UNIT DEVELOPMENT AT : 27 DUNOON STRET, DO NOT SCALE DRAWINGS.

DONCASTER. VIC 3108


USE FIGURED DIMENSIONS ONLY.
WD 03
A B C D E F G H I J K L

1
MATERIAL SCHEDULE
EF.1.01 DARK TONE CONCRETE ROOF TILE - NOM.'BORAL' MACQUARIE
(VIC) TWILIGHT
EF.1.02 DARK TONE METAL ROOFING SHEETING - NOM. 'COLORBOND'
KLIP-LOK - COLOUR: MONUMENT
EF.2.01 METAL ROOF FASCIA - NOM.'COLORBOND' - COLOUR: MACQUARIE (VIC) TWILIGHT
2
EF.2.02 METAL ROOF GUTTER - NOM.'COLORBOND' - COLOUR: MACQUARIE (VIC) TWILIGHT
EF.2.03 METAL BOX GUTTER - NOM.'COLORBOND' - COLOUR: ZINCALUME
EF.4.01 FACE BRICK VENEER 240mm - NOM.'AUSTRAL' BUILDERS RANGE - COLOUR: BURNT
ORANGE
EF.4.06 FACE BRICK RETAINING WALL DOUBLE 230mm- NOM.'MATCH BUILING' BUILDERS
RANGE - COLOUR: DARK TONE
EF.4.07 FACE BRICK DOUBLE PARTY WALL 270mm - NOM.'AUSTRAL' BUILDERS RANGE -
3
COLOUR: BURNT ORANGE
EF.5.01 WALL RENDER - NOM.'DULUX' - COLOUR: ABBEY WHITE B38
EF.7.01 EXTERNAL ALUMINIUM CASEMENT WINDOWS - NOM.'ACCENT WINDOWS' -
GLAZING: CLEAR - COLOUR: CLASSIC WOODLAND GREY - POWDERCOATED FINISH
EF.7.03 EXTERNAL ALUMINIUM AWNING WINDOWS - NOM.'ACCENT WINDOWS' - GLAZING:
CLEAR - COLOUR: CLASSIC WOODLAND GREY - POWDERCOATED FINISH
4
EF.7.04 EXTERNAL ALUMINIUM AWNING WINDOWS - NOM.'ACCENT WINDOWS' - GLAZING:
OBSURE - COLOUR: CLASSIC WOODLAND GREY - POWDERCOATED FINISH
EF.7.05 EXTERNAL ALUMINIUM AWNING WINDOWS - NOM.'ACCENT WINDOWS' - GLAZING:
OBSURE TO 1700mm ABOVE FLOOR LEVEL- COLOUR: CLASSIC WOODLAND GREY -
POWDERCOATED FINISH
EF.7.20 EXTEARNAL ALUMINIUM/TIMBER LOUVER WINDOW SCREENS - 25%
5 PERMEABILITY' TO 1.7m ABOVE FLOOR LEVEL (SATIN FINISH)
EF.9.01 SECTIONAL GARAGE DOOR - 'STEEL-LINE' DECOWOOD RANGE, IRON BARK FINISH
- SLIMLINE PROFILE
EF.10.03 DECKING - NOM.'MERBAU OR SPOTTED GUM' - COLOUR: 'DULUX' CLEARED FINISH
EF.10.04 FEATURE POST - NOM.'MERBAU OR SPOTTED GUM' - COLOUR: 'DULUX' CLEARED
FINISH
6
EF.13.01 SELECTED TIMBER PALING FENCE - '1800mm HIGH'
EF.17.01 WINDOWS SUNSCREEN OVER - POWDERCOATED FINISH

REF.IMAGE
7 WINDOWS RENDER
ROOF TILES CLASSIC BROWN
MACQUARIE (VIC) FASCIA & GUTTER WOODLAND BRICKWORK RENDER EXTERNAL
TWILIGHT MONUMENT GREY BURNT ORANGE CREAM WALLS

LOUVER
GARAGE DOOR FIVE LIGHT SCREENS CONCRETE
MANOR RED DOOR SATIN FINISH SPOTTED GUM DRIVEWAY

9
PROPOSED UNIT DEVELOPMENT
© COPYRIGHT
THIS DRAWING REMAINS THE
REVISIONS: A
PROPERTY OF RENOCO HOMES. DATE DESCRIPTION DATE: 22/09/2020
FOR : MS. XUELIN WANG DO NOT PRODUCE UNLAWFULLY. A 22/09/20 AS PER SECONDARY CONSENT DRAWN: M. Z / R. F
SCALES: AS SHOWN
AT : 27 DUNOON STRET, DO NOT SCALE DRAWINGS.

DONCASTER. VIC 3108


USE FIGURED DIMENSIONS ONLY.
WD 04
A B C D E F G H I J K L

Handrail : EX 90x45 pine


WINDOW & DOOR SCHEDULE Posts : EX 90x90 pine
125MM MAX'M GAP BETWEEN
VERTICAL BALLUSTERS. trenched.
Pine packing between
verticals top & bot rails
1
16380
2000 MAX'M Posts : EX 90x90 pine
NO SIZE ( W x H ) OPENABLE SIZE TYPE
7855 8255 VERTICALS : EX
W1 1800 x 1200 900 x 1200 ALUMINUM AWNING WINDOW 270 40x40 Pine owners

1000 MIN'M
W2 1800 x 1500 900 x 1500 ALUMINUM AWNING WINDOW 5435 240 2180 2180 240 5835 choice from
LAUNDRY LAUNDRY standard range
W3 800 x 1500 800 x 1500 ALUMINUM AWNING WINDOW balluster design

BOUNDARY
BOUNDARY
240 7615 8015 240
W4 1500 x 1200 750 x 1200 ALUMINUM AWNING WINDOW DINING / FAMILY DINING / FAMILY recessed 12.5mm
into top & bot rails
W5 3900 x 2730 0 ALUMINUM FIXED WINDOW
2250 90 3985 90 1200 1200 90 4135 90 2500
W6 3900 x 2730 0 ALUMINUM FIXED WINDOW PANTRY KITCHEN KITCHEN PANTRY

W7 1500 x 1200 750 x 1200 ALUMINUM AWNING WINDOW 1250 165 4270 90 2080 2230 90 4350 165 1420 FLOOR LEVEL Bot rail : EX 90x45
2
ALUMINUM AWNING WINDOW pine trenched.
W8 800 x 1500 800 x 1500 LIVING LIVING

Y
W9 1800 x 1500 900 x 1500 ALUMINUM AWNING WINDOW 5235
Selected 90 x 90 mm posts
TYPICAL INTERNAL HANDRAIL DETAIL

Z
DECK 100
W 10 1800 x 1200 900 x 1200 ALUMINUM AWNING WINDOW 5235 2595 ℄ 2540 ℄
Selected 90 x 90 mm posts
D1 1880 x 2100 1880 x 2100 1880mm FEATURE ENTRY DOOR
100
℄ 2540
DECK
℄ 2595
PROVIDE GRATED DRAIN AS REQUIRED
1:20@A1
D2 1880 x 2100 1880 x 2100 1880mm FEATURE ENTRY DOOR
A/J
UP ( STYLE & MATERIAL TO BE VERIFIED BY OWNER )

240
EF.10.03
PROVIDE GRATED DRAIN AS REQUIRED

1000
2000LT DP

70
D3 890 x 2100 890 x 2100 890mm FEATURE ENTRY DOOR

DECK
3500
EF.10.03
RAINWATER TANK ℄

LOUNDRY
A/J

240
DECK

2490
D4 2700 x 2100 900 x 2100

2250
SELECTED ALUMINUM SLIDING DOOR UNIT

2100

2400
2030
70
DP LAUNDRY

DECK
3500
℄ D6 FFL 82040
D5 3900 x 2180 3900 x 2180 SELECTED ALUMINUM FOLDING DOOR UNIT

LOUNDRY
DECK

2490

2250
A/J

2100
2400

2030
820 A/J
3 LAUNDRY
FFL 82480

240

240
D6 900 x 2100 900 x 2100 900mm FEATURE ENTRY DOOR WITH

90
D7 820 SLD
A/J 820 D5
590MM SIDE WINDOW A/J

240

90
820 SLD
D7 900 x 2100 900 x 2100 900mm FEATURE ENTRY DOOR WITH D8

590MM SIDE WINDOW DINING


W5

FAMILY + DINING
D8 3900 x 2180 3900 x 2180 SELECTED ALUMINUM FOLDING DOOR UNIT DINING UNIT 1

6710
D9 2700 x 2100 900 x 2100 SELECTED ALUMINUM SLIDING DOOR UNIT W6

FAMILY + DINING
D 10 890 x 2100 890 x 2100 890mm FEATURE ENTRY DOOR UNIT 2 FAMILY
6510x8010

6710
A/J
FFL 82090

9400

9400

9880
FAMILY DP

RAINWATER TANK
A/J FFL 82530 LINE OF EXTERNAL

2000LT
9880

9400

9400
DP FIRST FLOOR WALL
4
LINE OF EXTERNAL

90
FIRST FLOOR WALL
1050 sill

KITCHEN
90

720 SLD

2600
KITCHEN PANTRY
W4
W7

720 SLD
KITCHEN
A/J

2600
PANTRY KITCHEN 3
1050 sill 2
1

90

240
A/J
UP 540

26220
2
1

240

90
820

2940
UP 380

LIVING
2700 SLD

3400

3100

3100
s/a LIVING D4
820

2940
X 820 X

LIVING
3100

3100

3400
5 D9 LIVING s/a shower W3

90
2700 SLD
A/J
niche

240
820

90
720 SLD
PWR.

2000
W8 shower
NOTE :

90

ENSUITE
A/J
niche

ROBE
240

720 SLD
90

2155
PWR. ENSUITE 1

SLD
2000
BED 1
box gutters:

BED 1
3195
90 1560 90
SLD
W2

ENSUITE

720 SLD

720
2155
RwH: rainwater head with provision for overflow min.75mm+weir where rainwater heads cannot be

ROBE
ENSUITE 1

950 90
STORE.

BED 1
3195
BED 1 s/a

90 1560 90
A/J
W9
situated at the ends of box gutters, an internal sump discharging externally to rainwater head with

720 SLD
720
820

950 90
16

90
STORE.
additional provision for overflow as per AS3500.3 and VBA guide s/a 15

820 SLD
A/J 2 1
14
820 13
UP 350 D3
16 12 LINE OF EXTERNAL
90

15 11 FIRST FLOOR WALL

9280

9750
14 10
D10 LINE OF EXTERNAL

820 SLD
13 9
FIRST FLOOR WALL 12 8 selected min' GARAGE
6 11 7
9750

9280

10 6 1000mm high
NOTE :

GARAGE
9 5
GARAGE

6000
selected min' 8
7
4
3
handrail
6 2 A/J
separating wall between dwellings. timber stud framing to either side of 25mm boral 'partiwall' 1000mm high
GARAGE

5 1
FFL 81200
6000

4
handrail 3 UP
fire-rated panels to create total wall thickness of 270mm. install Bradford 'fire seal' party wall batt or A/J 2 s/a W1
FFL 82000 1

similar to gap between top of wall. install 50mm rockwool acoustic batts to timber framing to achieve UP
W10 s/a
FFL 81550 DP
Rw+Ctr of 50. install 2 layers of fire-resistant plasterboard lining,vertically within eaves to create ENTRY 2100H x 4800W

230
GARAGE DOOR
continuous barrier with separating wall. FFL 82150

570 430
DP

1000
A/J A/J
240 760 230

2100H x 4800W ENTRY


GARAGE DOOR
990
1000

A/J A/J A/J


FFL 81400
DRIVEWAY
D2
7
WINDOW NOTES : DRIVEWAY FFL 82000 A / J
D1
EF.10.04
- all nominal windows sizes to be verified prior to ordering

Y
Z

EF.10.04
- nominal sizes shown only; subject to change to suit builders manufacturers standard sizes. 540 1955 230 1735 540
PIER PIER
- all operable windows to have aluminium flyscreens ( optional )
- windows to be fabricated as per a.s. 2047 & all glazing to comply with a.s. 1288
500 270 500
- all windows in bedrooms less than 1.7m in height on first floor to have max. opening of not 240 3065 90 90 1700 1090 90 900 900 90 1240 1700 90 90 3315 240
more than 125mm. BED 1 ROBE ENSUIT PWR PWR ENSUIT ROBE BED 1
230 5455 90 2080 2230 90 5705 230
- provide laminated safety glass to windows within 500mm of floor level GARAGE ENTRY ENTRY GARAGE
5535 240 2080 2230 240 5785
8

7855 8255
NOTE : 16380
Provide 10mm expansion joints @6000 max' crs, in masonry walls above or close to junctions
between; different types of footing systems, footings founded at significantly different depths, or
footing founded on significantly different materials. (ie. clay & rock) also where new brickwork abutts
GROUND FLOOR PLAN NOTE :
existing brickwork. 1:100 @ A1 Articulation joint to be provided @ 4500mm max. spacing

9 NOTES: s/a Denotes location of smoke alarms, to be This plan is to be read and comply in accordance with the PROPOSED UNIT DEVELOPMENT
© COPYRIGHT
THIS DRAWING REMAINS THE
REVISIONS: A
Site & floor levels to be confirmed on site by builder installed in accordance with AS3786-1993. doors and window sashes. attached energy raters specification. PROPERTY OF RENOCO HOMES. DATE DESCRIPTION DATE: 22/09/2020
prior to commencement of any works if any Unless installed in an existing part of A class 1, FOR : MS. XUELIN WANG DO NOT PRODUCE UNLAWFULLY. A 22/09/20 AS PER SECONDARY CONSENT DRAWN: M. Z / R. F
discrepancies are found contact office immediately. 2 or 3 building or A class 4 part of a building, the non-required openings. These drawings shall be read in conjunction with all relevant SCALES: AS SHOWN
smoke alarm is to be hard wired with battery structural and all other consultants drawings/details.
AT : 27 DUNOON STRET, DO NOT SCALE DRAWINGS.

back-up & interconnected. required insulation. DONCASTER. VIC 3108


USE FIGURED DIMENSIONS ONLY.
WD 05
A B C D E F G H I J K L

Handrail : EX 90x45 pine


WINDOW & DOOR SCHEDULE Posts : EX 90x90 pine
125MM MAX'M GAP BETWEEN
VERTICAL BALLUSTERS. trenched.
Pine packing between
verticals top & bot rails
1 2000 MAX'M Posts : EX 90x90 pine
NO SIZE ( W x H ) OPENABLE SIZE TYPE
VERTICALS : EX
W 11 900 x 2020 900 x 2020 ALUMINUM AWNING WINDOW 40x40 Pine owners

1000 MIN'M
choice from

BOUNDARY
W 12 900 x 2020 900 x 2020 ALUMINUM AWNING WINDOW

BOUNDARY
15255 standard range
W 13 900 x 2020 900 x 2020 ALUMINUM AWNING WINDOW balluster design
W 14 700 x 900 350 x 900 ALUMINUM AWNING WINDOW 1065 6385 6660 1145 recessed 12.5mm
into top & bot rails
W 15 1800 x 1520 1800 x 470 ALUMINUM AWNING WINDOW
W 16 1000 x 590 1000 x 590 ALUMINUM AWNING WINDOW 165 3700 90 2430 270 2430 90 3700 165
BED 2 ENSUITE 2 ENSUITE 2 BED 2
W 17 1000 x 590 1000 x 590 ALUMINUM AWNING WINDOW FLOOR LEVEL Bot rail : EX 90x45
2 500 500
ALUMINUM AWNING WINDOW pine trenched.
W 18 1800 x 1520 1800 x 470 165 3130 90 90 950 2430 2430 950 90 90 3200 165

W 19
W 20
1800 x 600
1800 x 1500
900 x 600
900 x 1500
ALUMINUM AWNING WINDOW
ALUMINUM AWNING WINDOW
BED 5 ROBE STUDY / BATH STUDY / BATH ROBE BED 5
TYPICAL INTERNAL HANDRAIL DETAIL
W 21 600 x 600 600 x 600 ALUMINUM AWNING WINDOW 1:20@A1

Y
Z
W 22 600 x 600 600 x 600 ALUMINUM AWNING WINDOW ( STYLE & MATERIAL TO BE VERIFIED BY OWNER )
W 23 1800 x 1500 900 x 1500 ALUMINUM AWNING WINDOW
PERGOLA
W 24 1800 x 600 900 x 600 ALUMINUM AWNING WINDOW
W 25 1800 x 1520 1800 x 470 ALUMINUM AWNING WINDOW PERGOLA
cupboard
3 W 26 1000 x 590 1000 x 590 ALUMINUM AWNING WINDOW behind mirror W20
W 27 1000 x 590 1000 x 590 ALUMINUM AWNING WINDOW shower RwH W21

165
W 28 1800 x 1520 1800 x 470 ALUMINUM AWNING WINDOW W23 niche

1005
W22 RwH
W 29 900 x 500 900 x 500 ALUMINUM AWNING WINDOW ENSUITE 2 shower

ENSUITE 2
165

2600
HIGH WINDOW
W 30 900 x 2020 900 x 2020 ALUMINUM AWNING WINDOW 720 niche
BED 2

4060
BED 2
ENSUITE 2

3970
W 31 900 x 2020 900 x 2020 ALUMINUM AWNING WINDOW cupboard W19

2455
720 ENSUITE 2 FFL 85030

HIGH WINDOW
SAUNA

behind mirror

90
W 32 600 x 2020 600 x 2020 ALUMINUM AWNING WINDOW

4060

BED 2
3970
BED 2
W24

720 SLD
FFL 85230

1800
WIR. DP

1425 90

WIR
720 SLD
(spreader)
WIR.

90
WIR
DP

90
820
(spreader)

90

SLD
4

ROBE

STORAGE
820 SLD 820

BED 5
2445
SKYLIGHT

3555
STORAGE

STORAGE
ABOVE

3885
1260 s/a BED 5

90 1720
W18

820 SLD
SLD
ROBE
SKYLIGHT
ABOVE
900 STORAGE

BED 5
3555
select 800 x

3885
W25
BED 5 s/a

90 90
3180x3550 SKYLIGHT
500 skylight

500
CUP
ABOVE
CUP 820

165
BATH

BATH
1745
1
select 800 x SKYLIGHT SLD UP 180
500 skylight
ABOVE
W17

UNIT 1
820 720

165
1

90
21305

21305
TV ROOM

3005
UP 180

3155
W26
shower FFL 84850 DP

UNIT 2 (spreader)

TV ROOM
TV ROOM
niche

3155
3005 X DP W16 X
(spreader) FFL 85050

165
90
TV ROOM
5 W27

SLD
165

ROBE

ROBE
90

90 1900
BED 4

4760
BED 4
2930
W15
NOTE : select 800 x

ROBE
ROBE
2280
500 skylight shower

SLD
BED 4
3530

BED 4
3440
box gutters: W28 900 SKYLIGHT
ABOVE
820 niche

90
RwH: rainwater head with provision for overflow min.75mm+weir where rainwater heads cannot be 1070 90
720

500 930 900


2950
DN16 s/a

90 90 BATH 90 WC
SKYLIGHT
select 800 x ABOVE
900 15 WC

BATH
1920
W14 shower
situated at the ends of box gutters, an internal sump discharging externally to rainwater head with DP
(spreader) 500 skylight 820
s/a 14
13 BATH DP
165

16 DN 12 (spreader) niche
90 90

ROBE

165
820
additional provision for overflow as per AS3500.3 and VBA guide
500

15 11 720
ROBE 14 10
select 800 x

STAIRS

ROBE
3750
820
13 9
SLD ROBE
12 8
500 skylight

720 SLD

ENSUITE 3
11 7 SKYLIGHT
ENSUITE 3

2600
SLD

2930
ABOVE
10 6

720 SLD
STAIRS
3835

3750
4165

9 5
ENSUITE 3 8 4
ENSUITE 3
BED 3
BED 5

6 W29 7 3
5495

selected min'

BED 3
3990
6 2

NOTE :

BED 3
5

3400
BED 3 1
BED 3
4905

165
4
3
1000mm high
DP

ID
selected min' 2 handrail

VOID
separating wall between dwellings. timber stud framing to either side of 25mm boral 'partiwall'

1765
VO
(spreader)

1660
1
1000mm high
165

fire-rated panels to create total wall thickness of 270mm. install Bradford 'fire seal' party wall batt or shower DP

ID
(spreader) handrail

165
VO
1765
VOID
1660

similar to gap between top of wall. install 50mm rockwool acoustic batts to timber framing to achieve niche

1005
RwH
W11 W12 W13
165

Rw+Ctr of 50. install 2 layers of fire-resistant plasterboard lining,vertically within eaves to create
W30 W31 W32 RwH
continuous barrier with separating wall.

Y
Z

7
WINDOW NOTES :
- all nominal windows sizes to be verified prior to ordering 2230 165 5055 5055 165 2310
TV ROOM TV ROOM
- nominal sizes shown only; subject to change to suit builders manufacturers standard sizes. 90 90
500 1500 1410 500 3835
- all operable windows to have aluminium flyscreens ( optional ) BED 4
ROBE ROBE
- windows to be fabricated as per a.s. 2047 & all glazing to comply with a.s. 1288
165 3750 90 2090 2000 90 1600 90 2145 165
- all windows in bedrooms less than 1.7m in height on first floor to have max. opening of not BED 4 WC BATH
more than 125mm. 165 1580 90 2900 90 1320 1320 90 2900 90 1580 165
- provide laminated safety glass to windows within 500mm of floor level ENSUITE 3 ROBE ROBE ENSUITE 3
165 4305 90 1000 270 1000 90 4305 165
BED 3 STAIRS STAIRS BED 3
8
1670 5830 5565 1670

NOTE : 14730

Provide 10mm expansion joints @6000 max' crs, in masonry walls above or close to junctions
between; different types of footing systems, footings founded at significantly different depths, or
footing founded on significantly different materials. (ie. clay & rock) also where new brickwork abutts
FIRST FLOOR PLAN NOTE :
Foam board panel (Unitex Base Board)to first floor external
existing brickwork. 1:100 @ A1 wall as per manufacturer's specifications

9 NOTES: s/a Denotes location of smoke alarms, to be This plan is to be read and comply in accordance with the PROPOSED UNIT DEVELOPMENT
© COPYRIGHT
THIS DRAWING REMAINS THE
REVISIONS: A
Site & floor levels to be confirmed on site by builder installed in accordance with AS3786-1993. doors and window sashes. attached energy raters specification. PROPERTY OF RENOCO HOMES. DATE DESCRIPTION DATE: 22/09/2020
prior to commencement of any works if any Unless installed in an existing part of A class 1, FOR : MS. XUELIN WANG DO NOT PRODUCE UNLAWFULLY. A 22/09/20 AS PER SECONDARY CONSENT DRAWN: M. Z / R. F
discrepancies are found contact office immediately. 2 or 3 building or A class 4 part of a building, the non-required openings. These drawings shall be read in conjunction with all relevant SCALES: AS SHOWN
smoke alarm is to be hard wired with battery structural and all other consultants drawings/details.
AT : 27 DUNOON STRET, DO NOT SCALE DRAWINGS.

back-up & interconnected. required insulation. DONCASTER. VIC 3108


USE FIGURED DIMENSIONS ONLY.
WD 06
A B C D E F G H I J K L

SITE BOUNDARY
UNIT 1 UNIT 2 EF.1.01
EF.2.01
EF.2.02 UNIT 2 UNIT 1
EF.7.20 EF.5.01
EF.7.20 EF.5.01 EF.7.20 EF.17.01
EF.5.01 EF.7.01 EF.7.01 EF.7.01 EF.1.01

SITE BOUNDARY
EF.17.01 EF.7.03 EF.7.03 EF.2.02
2 EF.7.20 EF.7.01 EF.7.01 EF.7.01
TOP OF BUILDING TOP OF BUILDING TOP OF BUILDING TOP OF BUILDING
EF.17.01

SITE BOUNDARY

SITE BOUNDARY
88974 89074 89074 88974

OVERALL BUILDING HEIGHT


364

364
UNIT 1 FIRST FLOOR CL FIRST FLOOR CL UNIT 2 FIRST FLOOR CL UNIT 2 UNIT 1 FIRST FLOOR CL

OVERALL BUILDING HEIGHT


OVERALL BUILDING HEIGHT

87550 87630 87630 87550


F

2400
F
2520

OVERALL BUILDING HEIGHT


2580
NEW 1.8m HIGH TIMBER

2700
1700

OVERALL WALL HEIGHT


PALING FENCE

1700

6487

6910
UNIT 1 FIRST FLOOR FFL
UNIT 1 FIRST FLOOR FFL
7060

UNIT 2 FIRST FLOOR FFL

4560

OVERALL WALL HEIGHT


UNIT 2 FIRST FLOOR FFL 85230

300

7835
5513
85030

5400
5428
85050 84850
300

300
SENSOR

300
LIGHT
UNIT 2 GROUND CL

TIMBER PALING FENCE


UNIT 1 GROUND CL

6748
UNIT 2 GROUND CL UNIT 1 GROUND CL

2400
84930 SENSOR
84730 84750

2864
LIGHT
84550

2600
2640

3586

NGL

1800
3

3000
UNIT 2 GROUND FFL UNIT 2 GROUND FFL
SHED SHED EF.13.01
UNIT 1 GROUND FLOOR SPLIT 82530 82150
FFL UNIT 1 GROUND FFL
82090 EF.4.01
UNIT 2 GARAGE FFL 81550
NGL Site cut Site cut EF.4.06
82000 EF.10.04
1500 CAVITY FLASHING & WEEP 1500
Retaining wall EF.4.06 UNIT 1 GARAGE FFL
New 1.8m high 1500 EF.4.06 EF.9.01
HOLES @ 900mm CTR. ABOVE EF.10.04 1500 81200
SETBACK timber paling fence SETBACK SETBACK
LOWER STOREY DOORS. SETBACK

NORTH ELEVATION SOUTH ELEVATION


4
1:100 @ A1 1:100 @ A1
UNIT 1
EF.17.01
EF.7.04 EF.17.01 EF.7.03 EF.7.03 EF.7.05

SITE BOUNDARY
EF.5.01
EF.5.01
SITE BOUNDARY

EF.7.05
EF.5.01 EF.7.03 TOP OF BUILDING
TOP OF BUILDING
88915 88974
EF.5.01
EF.7.20
UNIT 1 FIRST FLOOR CL UNIT 1 FIRST FLOOR CL
87550 87550

OVERALL BUILDING HEIGHT


OVERALL BUILDING HEIGHT

2520
new 1.8m high timber
2700

F
FIXED OBSCURE GLASS
FIXED OBSCURE GLASS paling fence

1700
1700mm ABOVE FFL
1700mm ABOVE FFL
5 UNIT 1 FIRST FLOOR FFL

1700
1700

7330
7623

84850 UNIT 1 FIRST FLOOR FFL

300
300

EF.13.01 85030

5980
6100
6429

UNIT 1 GROUND CL
UNIT 1 GROUND CL GLAZED WINDOW
TOP OF BOUNDARY FENCE
84730

2640
84550

2000
Boundary fence
3000

3584
3486

F
3324

SHED
F F
UNIT 1 GROUND FFL UNIT 1 GROUND FLOOR SPLIT

81550 82090

UNIT 1 GARAGE FFL 1:8 EF.4.06 EF.5.01


New 1.8m high Storm drain to EASEMENT
81200 NGL Cavity flashing & weep holes timber paling fence be provided
New 1.8m high
@ 900mm ctr. above lower
6 timber paling fence
storey windows.

EAST ELEVATION
1000
1:100 @ A1
1570

EF.5.01
F.4.07
UNIT 2 EF.1.01
SITE BOUNDARY

SITE BOUNDARY
EF.7.03 EF.7.03
EF.7.03 EF.5.01 EF.2.02
TOP OF BUILDING EF.7.20 EF.7.03 EF.5.01 TOP OF BUILDING
EF.7.03 EF.7.03 EF.7.20 EF.4.07
EF.7.20
7 89074 89074
retractable clothes
line on steel frame

OVERALL BUILDING HEIGHT


OVERALL BUILDING HEIGHT

FIRST FLOOR CL UNIT 2 FIRST FLOOR CL UNIT 2

87630 87630
new 1.8m high timber F
F F
2400

paling fence

2580
UNIT 2 FIRST FLOOR FFL UNIT 2 FIRST FLOOR FFL
1700
6200

1700

6411
85230 new 1.8m high boundary 85050
4503

timber paling fence Boundary fence


4879

4931
300

5106

5150

300
UNIT 2 GROUND CL
UNIT 2 GROUND CL 84750
GLAZED WINDOW
2505

84930 F
2400

2777

2600
NGL
F
UNIT 2 GROUND FFL SHED F UNIT 2 GROUND FFL
8 LETTERBOX
82150
82530 EASEMENT NGL 1:11
Site cut EF.4.01 UNIT 2 GARAGE FFL
Storm drain to Storm drain to Site cut EF.7.03 EF.4.06 EF.7.03
be provided be provided New 1.8m high New 1.8m high 82000

timber paling fence timber paling fence

Cavity flashing & weep holes @

WEST ELEVATION 900mm ctr. above lower storey


windows.

1:100 @ A1
© COPYRIGHT REVISIONS: A
9
NOTES NOTES PROPOSED UNIT DEVELOPMENT THIS DRAWING REMAINS THE
PROPERTY OF RENOCO HOMES. DATE DESCRIPTION DATE: 22/09/2020
all levels shown are approximate only and are to all windows in bedrooms less than FOR : MS. XUELIN WANG DO NOT PRODUCE UNLAWFULLY. A 22/09/20 AS PER SECONDARY CONSENT DRAWN: M. Z / R. F
be verified by builder prior to commencement of 1700mm height on first floor to have a AT : 27 DUNOON STRET, DO NOT SCALE DRAWINGS.
SCALES: AS SHOWN

any construction works max' opining of not more than 125mm. DONCASTER. VIC 3108
USE FIGURED DIMENSIONS ONLY.
WD 07
A B C D E F G H I J K L

300w x 100d (min') colorbond box gutter to


discharge into selected rainwater heads. Builder to
flashing as fully line underside & sides of box gutter with
gutterboard. Box gutter set to fall i in 100. Provide
NOTES required
colorbond capping to parapet walls. (typ)
1
NOTES separating wall between dwellings. 300w x 100d (min') colorbond box gutter to
discharge into selected rainwater heads. Builder to
timber stud framing to either side of 25mm boral 'partiwall' fire-rated panels fully line underside & sides of box gutter with
all timber framing to comply with the requirements of the to create total wall thickness of 270mm.
gutterboard. Box gutter set to fall i in 100. Provide
colorbond capping to parapet walls. (typ) Refer to truss manufacturers documentation
for all details on pre-favricated roof framing

s.a.a. timber framing code as1684-2010 (latest edition) install Bradford 'fire seal' party wall batt or similar to gap between top of (typ) @600 cts. All dimensions to be verified
on site prior to manufacture & installation.
wall.
10mm plasterboard wall & ceiling lining,
install 50mm rockwool acoustic batts to timber framing to achieve Rw+Ctr for fixing refer to manufacturers details.
studs @450mm max' cts. (typ)
refer to engineers design & computations for beam sizes of 50. Roofing shall comply to A.S.
2050-2002 & A.S. 2049 -2002. (typ)

install 2 layers of fire-resistant plasterboard lining,vertically within eaves to


& locations supports & connection details create continuous barrier with separating wall.
2 Studs with noggins @1350mm
max' cts. as per as eng's design
Selected boral partiwall

roof trusses drawn indicative only, to be designed & NOTE


system(25TP1010A). Refer to
manufacturer for details. To achieve fire
rating 60/60/60.

specified as per manufacturers requirements SARKING UNDER ALL KLIP-LOK FLAT METAL ROOFS OVER PARTS OF THE DWELLING

DETAIL 1
1:20
( STYLE & MATERIAL TO BE VERIFIED BY OWNER )
3

UNIT 1

SITE BOUNDARY

SITE BOUNDARY
UNIT 1
on graded roofing battens @ 1200mm cts on rafters
@ 900mm cts as per engineer's design
UNIT 2 battens @ 330 cts. on prefabricated roof trusses to battens @ 330 cts. on prefabricated roof trusses to battens @ 330 cts. on prefabricated roof trusses to
manufactures design & specifications @600 mm cts. selected colorbond manufactures design & specifications @600 mm cts. manufactures design & specifications @600 mm cts.
fascias and gutters
selected colorbond
SITE BOUNDARY

TOP OF BUILDING fascias and gutters


TOP OF BUILDING
TOP OF BUILDING DETAIL " 1 " TOP OF BUILDING
88974 88974
89074

SITE BOUNDARY
450 88974 450 450 450 450
eave eave eave eave eave
UNIT 1 FIRST FLOOR CL UNIT 1 FIRST FLOOR CL
FIRST FLOOR CL UNIT 2 UNIT 1 FIRST FLOOR CL
87550 BED 3 87550
4 87630 87550 ENSUITE 5 BATH BED 4
75mm foam board (Unitex Base Board) 75mm foam board (Unitex
cladding with selected render finish for W19 Base Board ) cladding with
2580

W16 W17

2700
W18

2520
2520
TV ROOM

2700
upper floor. selected render finish for
2580

2700

2700
TV ROOM upper floor. on graded roofing battens @ 1200mm cts on
75mm foam board (Unitex Base Board) rafters @ 900mm cts as per engineer's design UNIT 1 FIRST FLOOR FFL
UNIT 2 FIRST FLOOR FFL selected beams as cladding with selected render finish for selected beams as flash as
per eng's design 85230 19mm particleboard flooring upper floor. 19mm particleboard flooring 85030 85030
UNIT 1 FIRST FLOOR FFL per eng's design 84850 required

300
85050 730 ( yellow tongue ) 84850 flash as UNIT 1 FIRST FLOOR FFL ( yellow tongue )
300

300
required

300
84850 UNIT 1 GROUND CL
UNIT 2 GROUND CL 84850 posistruts @ 450 max. crs as per
posistruts @ 450 max. crs as per UNIT 1 GROUND CL posistruts @ 450 max. crs as per 10mm superspan plasterboard or engineer's design & specifications.

84750
500 engineer's design & specifications. on graded roofing battens @ 1200mm cts on
UNIT 1 GROUND CL engineer's design & specifications. 13mm plasterboard to ceiling and 84730

2640
rafters @ 900mm cts as per engineer's design 84550 10mm plasterboard to walls
2600

300W X 100D 10mm superspan plasterboard or

2640
84550
2600

PANTRY FAMILY

2240
box gutter 13mm plasterboard to ceiling and DINING

3000
3000
LIVING

3000
10mm plasterboard to walls W5
3000

300W X 100D

3350
UNIT 2 GROUND FFL
D9
PWR LIVING box gutter GARAGE BED 1 LIVING SHED ON
19mm particleboard
82090
19mm particleboard flooring LEVEL SURFACE UNIT 1 GROUND FLOOR SPLIT
82150 82150 flooring ( yellow tongue ) ( yellow tongue ) D6 82040 FFL
D4
concrete slab as per UNIT 1 GROUND FFL 81550 82090
81550 engineer's design UNIT 1 GROUND FFL 81400 NGL
81200
81550
81550
5 1:8
UNIT 1 GARAGE FFL 80000 compact fill as per Selected polycarbonate on 190x45mm
NGL engineer's design
concrete slab with edge beams and stiffening beams eng's design & specification
dush line denotes 50mm min' 81200 as per engineer's design & specifications.
compacted sand bed.
dush line denotes 50mm min'
graded roofing battens @ 1200mm cts on rafters @ compacted sand bed.
900mm cts as per engineer's design concrete slab with edge beams and
stiffening beams as per

SECTION X - X SECTION Y - Y engineer's design & specifications.

1:100 @ A1 1:100 @ A1

UNIT 2 ALL TREADS, LANDINGS AND


THE LIKE TO HAVE NON SLIP
battens @ 330 cts. on prefabricated roof trusses to battens @ 330 cts. on prefabricated roof trusses to
FINISH OR SUITABLE NON-SKID
SITE BOUNDARY

manufactures design & specifications @600 mm cts. manufactures design & specifications @600 mm cts.
STRIP NEAR EDGE OF NOSING.

SITE BOUNDARY
TOP OF BUILDING TOP OF BUILDING PROVIDE SLIP RESISTANCE
SURFACE OR EDGE STRIP (P3
89074 selected colorbond 89074 DRY) AND (P4 WET) TO
75mm foam board cladding with
450 450 450 450 fascias and gutters 250 MIN
selected render finish for upper floor. TREADS OF STAIRS. TREAD
eave eave eave eave
FIRST FLOOR CL UNIT 2 FIRST FLOOR CL UNIT 2
TREAD:
87630 87630 EX: 300 x 41
75mm foam board (Unitex Base Board)
7 cladding with selected render finish for RADIATA PINE.
2400

W26 W27
upper floor.
2400

90x90mm posts as per eng's design & specification BED 2 OR SELECTED TIMBER
2580

BED 3

2580
UNIT 2 FIRST FLOOR FFL BED 4 ENSUITE 5 UNIT 2 FIRST FLOOR FFL

85230 selected beams as 85050


85230 per eng's design 19mm particleboard flooring flash as
85050
300

( yellow tongue ) required

300
STRINGER:
UNIT 2 GROUND CL
posistruts @ 450 max. crs as per EX: 300 x 38
UNIT 2 GROUND CL LIVING posistruts @ 450 max. crs as per 190 MAX
engineer's design & specifications. 84750 RADIATA PINE.
84930 engineer's design & specifications.
2400

OR SELECTED TIMBER
2400

10mm superspan plasterboard or


2240

DINING FAMILY PANTRY


SHED ON
2600

13mm plasterboard to ceiling and

2600
2750

W8
10mm plasterboard to walls BED 1 GARAGE
NGL LEVEL SURFACE
19mm particleboard flooring UNIT 2 GROUND FFL
UNIT 2 GROUND FFL 82480 D7 82530 ( yellow tongue )
82150 82150
82530 82000
EASEMENT 1:11 NGL
UNIT 2 GARAGE FFL
treated timber post in galvanized
81200
stirrup encased in piers (min. H3) 82000
dush line denotes 50mm min'
concrete slab with edge beams and stiffening
compacted sand bed. concrete slab with edge beams and stiffening beams
8 beams as per engineer's design & specifications.
as per engineer's design & specifications.

graded roofing battens @ 1200mm cts on rafters @


900mm cts as per engineer's design SECTION Z - Z on graded roofing battens @ 1200mm cts on
rafters @ 900mm cts as per engineer's design STAIR DETAIL
1:100 @ A1 1:10
( STYLE & MATERIAL TO BE VERIFIED BY OWNER )

© COPYRIGHT REVISIONS: A
9
NOTES NOTES PROPOSED UNIT DEVELOPMENT THIS DRAWING REMAINS THE
PROPERTY OF RENOCO HOMES. DATE DESCRIPTION DATE: 22/09/2020
all levels shown are approximate only and are to all windows in bedrooms less than FOR : MS. XUELIN WANG DO NOT PRODUCE UNLAWFULLY. A 22/09/20 AS PER SECONDARY CONSENT DRAWN: M. Z / R. F
be verified by builder prior to commencement of 1700mm height on first floor to have a AT : 27 DUNOON STRET, DO NOT SCALE DRAWINGS.
SCALES: AS SHOWN

any construction works max' opining of not more than 125mm. DONCASTER. VIC 3108
USE FIGURED DIMENSIONS ONLY.
WD 08
A B C D E F G H I J K L

ELECTRICAL SYMBOL LEGEND


1
CEILING MOUNTED LIGHT BATTEN

CEILING MOUNTED LOW-VOLTAGE DOWNLIGHT


ELECTRICAL LAYOUT
WALL LIGHT LOW LEVEL MOUNTED STAIRWAY
LIGHTING REQUIREMENTS GROUND FLOOR LIGHTING ' UNIT 1 '
WALL MOUNTED LIGHT (HEIGHT SPECIFIED) GROUND FLOOR LIGHTING ' UNIT 2 ' LAMP POWER DENSITY OR ILLUMINATION POWER GROUND FLOOR AREA: 154.17 M.sq.
MUST NOT EXCEED ANALYSIS Watts PER SQUARE METRE MAXIMUM 5W PER SQUARE METRE
2 GROUND FLOOR AREA: 147.86 M.sq.
CEILING MOUNTED FLUORESCENT LIGHT MAXIMUM USAGE: 770.85 W
MAXIMUM 5W PER SQUARE METRE
MAXIMUM USAGE: 739.3 W
FLOOD LIGHT LIGHTING FIXTURE MODEL No. OF Watts PER FIXTURE

Watts PER FIXTURE No. OF LIGHTING FIXTURE MODEL


WALL LIGHT OUTLET @ 1800mm

CEILING LIGHT OUTLET 1100

TOTAL Watts Watts


2w

1100
3 2 WAY SWITCH
ay

Watts TOTAL Watts


S
SENSOR

DS
DAYLIGHT SENSOR
UNIT 1
3 IN 1 BATHROOM HEAT, LIGHT & EXHAUST FAN UNITS TO COMPLY WITH AS 1668.2
UNIT 2
GARAGE LIGHTING ' UNIT 1 '

TV
GARAGE LIGHTING ' UNIT 2 ' GARAGE FLOOR AREA: 38.00 M.sq.

TV
DOUBLE FLOOD LIGHT TO UNDERSIDE OF EAVE
4
GARAGE FLOOR AREA: 36.51 M.sq. spp @750mm
MAXIMUM 3W PER SQUARE METRE
CEILING MOUNTED JUNCTION BOX MAXIMUM 3W PER SQUARE METRE
high for D/W MAXIMUM USAGE: 114 W
spp @750mm
s/a MAXIMUM USAGE: 109.53 W high for D/W FMG @ 1500mm H
LIGHTING FIXTURE MODEL No. OF Watts PER FIXTURE
CEILING MOUNTED MAINS POWERED SMOKE DETECTOR
Watts PER FIXTURE No. OF LIGHTING FIXTURE MODEL FMG @ 1500mm H
1100 1100 1100

CEILING MOUNTED FAN 1100 1100 1100

spp @1800mm
CEILING MOUNTED EXHAUST FAN high for rangehood
5 TOTAL Watts Watts

2 way
spp @1800mm high
Watts TOTAL Watts

2 way
SINGLE G.P.O. AT 300mm ABOVE F.F.L.
for rangehood

1100
DOUBLE G.P.O. AT 300mm ABOVE F.F.L.
PORCH LIGHTING ' UNIT 1 '

1100
EXT
EXTERNAL POWER POINT PORCH LIGHTING ' UNIT 2 ' s/a

power point to ceiling


PORTICO AREA: 2.83 M.sq.
PORTICO AREA: 2.63 M.sq. power point to ceiling s/a for garage door MAXIMUM 4W PER SQUARE METRE
SINGLE G.P.O. (HEIGHT SPECIFIED) MAXIMUM 4W PER SQUARE METRE for garage door MAXIMUM USAGE: 11.32 W
6 MAXIMUM USAGE: 10.52 W
FLUR. LIGHT LIGHTING FIXTURE MODEL No. OF Watts PER FIXTURE
DOUBLE G.P.O. (HEIGHT SPECIFIED)

2 way
Watts PER FIXTURE No. OF LIGHTING FIXTURE MODEL FLUR. LIGHT

PH
TELEPHONE POINT AT 300mm ABOVE F.F.L.
s/a

2 way
TV
TELEVISION COAXIAL POINT AT 300mm ABOVE F.F.L. s/a

TOTAL Watts Watts


DS
DATA POINT AT 300mm ABOVE F.F.L. Watts TOTAL Watts
DS
7
D.V. DUCTED VACUUM SYSTEM

MH MANHOLE

HWS HOT WATER SERVICE

FLOOR HEATING / COOLING OUTLET GROUND FLOOR PLAN NOTE :


8 DHU DUCTED HEATING UNIT IN ROOF SPACE (INCL. G.P.O. AS REQUIRED)
1:100 @ A1 - ALL ELECTRICAL LOCATIONS ARE INDICATIVE ONLY. EXACT LOCATIONS TO BE
CONFIRMED ON SITE,
- ALL WIRING AND INSTALLATION TO COMPLY WITH RELEVANT AUTHORITIES.
- PROVIDE SELF CONTAINED SMOKE ALARMS CONNECTED TO MAINS POWER WITH
CEILING MOUNTED HEATING / COOLING OUTLET STANDBY POWER IN ACCORDANCE WITH THE NATIONAL CONSTRUCTION CODE & AS
3786-1993 INSTALLATION TO MANUFACTURERS SPECIFICATIONS.
- MECHANICAL VENTILATION TO BE DUCTED TO ROOF SPACE TO COMPLY WITH THE
METER BOX NATIONAL CONSTRUCTION CODE UNLESS NOTED OTHERWISE

9 NOTES: s/a Denotes location of smoke alarms, to be This plan is to be read and comply in accordance with the PROPOSED UNIT DEVELOPMENT
© COPYRIGHT
THIS DRAWING REMAINS THE
REVISIONS: A
Site & floor levels to be confirmed on site by builder installed in accordance with AS3786-1993. doors and window sashes. attached energy raters specification. PROPERTY OF RENOCO HOMES. DATE DESCRIPTION DATE: 22/09/2020
prior to commencement of any works if any Unless installed in an existing part of A class 1, FOR : MS. XUELIN WANG DO NOT PRODUCE UNLAWFULLY. A 22/09/20 AS PER SECONDARY CONSENT DRAWN: M. Z / R. F
discrepancies are found contact office immediately. 2 or 3 building or A class 4 part of a building, the non-required openings. These drawings shall be read in conjunction with all relevant SCALES: AS SHOWN
smoke alarm is to be hard wired with battery structural and all other consultants drawings/details. AT : 27 DUNOON STRET, DO NOT SCALE DRAWINGS.

back-up & interconnected. required insulation. DONCASTER. VIC 3108


USE FIGURED DIMENSIONS ONLY.
WD 09
A B C D E F G H I J K L

ELECTRICAL SYMBOL LEGEND


1
CEILING MOUNTED LIGHT BATTEN

CEILING MOUNTED LOW-VOLTAGE DOWNLIGHT


ELECTRICAL LAYOUT
WALL LIGHT LOW LEVEL MOUNTED STAIRWAY
LIGHTING REQUIREMENTS
WALL MOUNTED LIGHT (HEIGHT SPECIFIED) LAMP POWER DENSITY OR ILLUMINATION POWER
MUST NOT EXCEED ANALYSIS Watts PER SQUARE METRE
2
CEILING MOUNTED FLUORESCENT LIGHT FIRST FLOOR LIGHTING ' UNIT 1 '
FLOOD LIGHT
FIRST FLOOR LIGHTING ' UNIT 2 ' FIRST FLOOR AREA: 133 M.sq.
FIRST FLOOR AREA: 134 M.sq. MAXIMUM 5W PER SQUARE METRE
MAXIMUM 5W PER SQUARE METRE MAXIMUM USAGE: 665 W
WALL LIGHT OUTLET @ 1800mm
MAXIMUM USAGE: 670 W
LIGHTING FIXTURE MODEL Watts PER FIXTURE
CEILING LIGHT OUTLET
Watts PER FIXTURE No. OF LIGHTING FIXTURE MODEL
2w

3 2 WAY SWITCH
ay

S
SENSOR
TOTAL Watts Watts
DS Watts TOTAL Watts
DAYLIGHT SENSOR

1100
3 IN 1 BATHROOM HEAT, LIGHT & EXHAUST FAN UNITS TO COMPLY WITH AS 1668.2 2 way

2 way

1100
DOUBLE FLOOD LIGHT TO UNDERSIDE OF EAVE
4

CEILING MOUNTED JUNCTION BOX


s/a
s/a
CEILING MOUNTED MAINS POWERED SMOKE DETECTOR
UNIT 1
s/a

1100

CEILING MOUNTED FAN UNIT 2 TV

TV
CEILING MOUNTED EXHAUST FAN
5

SINGLE G.P.O. AT 300mm ABOVE F.F.L.

DOUBLE G.P.O. AT 300mm ABOVE F.F.L.

EXT
EXTERNAL POWER POINT
s/a
1100

2 way
s/a

2 way
SINGLE G.P.O. (HEIGHT SPECIFIED)
1100
6
DOUBLE G.P.O. (HEIGHT SPECIFIED)

1100
2 way
PH 2 way

TELEPHONE POINT AT 300mm ABOVE F.F.L.

y
2 wa
TV
TELEVISION COAXIAL POINT AT 300mm ABOVE F.F.L.

DATA POINT AT 300mm ABOVE F.F.L.

7
D.V. DUCTED VACUUM SYSTEM

MH MANHOLE

HWS HOT WATER SERVICE

FLOOR HEATING / COOLING OUTLET FIRST FLOOR PLAN NOTE :


8 DHU DUCTED HEATING UNIT IN ROOF SPACE (INCL. G.P.O. AS REQUIRED)
1:100 @ A1 - ALL ELECTRICAL LOCATIONS ARE INDICATIVE ONLY. EXACT LOCATIONS TO BE
CONFIRMED ON SITE,
- ALL WIRING AND INSTALLATION TO COMPLY WITH RELEVANT AUTHORITIES.
- PROVIDE SELF CONTAINED SMOKE ALARMS CONNECTED TO MAINS POWER WITH
CEILING MOUNTED HEATING / COOLING OUTLET STANDBY POWER IN ACCORDANCE WITH THE NATIONAL CONSTRUCTION CODE & AS
3786-1993 INSTALLATION TO MANUFACTURERS SPECIFICATIONS.
- MECHANICAL VENTILATION TO BE DUCTED TO ROOF SPACE TO COMPLY WITH THE
METER BOX NATIONAL CONSTRUCTION CODE UNLESS NOTED OTHERWISE

9 NOTES: s/a Denotes location of smoke alarms, to be This plan is to be read and comply in accordance with the PROPOSED UNIT DEVELOPMENT
© COPYRIGHT
THIS DRAWING REMAINS THE
REVISIONS: A
Site & floor levels to be confirmed on site by builder installed in accordance with AS3786-1993. doors and window sashes. attached energy raters specification. PROPERTY OF RENOCO HOMES. DATE DESCRIPTION DATE: 22/09/2020
prior to commencement of any works if any Unless installed in an existing part of A class 1, FOR : MS. XUELIN WANG DO NOT PRODUCE UNLAWFULLY. A 22/09/20 AS PER SECONDARY CONSENT DRAWN: M. Z / R. F
discrepancies are found contact office immediately. 2 or 3 building or A class 4 part of a building, the non-required openings. These drawings shall be read in conjunction with all relevant SCALES: AS SHOWN
smoke alarm is to be hard wired with battery structural and all other consultants drawings/details. AT : 27 DUNOON STRET, DO NOT SCALE DRAWINGS.

back-up & interconnected. required insulation. DONCASTER. VIC 3108


USE FIGURED DIMENSIONS ONLY.
WD 10
A B C D E F G H I J K L

1
UNIT " 1 "
C. L. C. L.

SH SH
SH SH SH SH SH SH
SH
2
SH
SH SH SH SH SH SH

( PROPOSED )

( PROPOSED )
2
R/H

2640

2640
SH
KITCHEN H/P &
REF UBO SH S
1 SPACE Selected
DR
SH Splashback SH
UBO DR D/W
3

F. L. F. L. DR SH

25 900 25 479 479 600 479 479 Slide out bin


40 445 445 445 360 400 400 600 40 955

4
KITCHEN FLOOR PLAN -UNIT " 1 " KITCHEN ELEVATION " 1 " KITCHEN ELEVATION " 2 "
1: 50 @ A3 1:50 1:50

460 460 900 339 339 500 500 500 500 500
5

C. L. C. L. C. L.

SH SH SH SH SH SH SH SH SH SH SH SH

SH SH SH SH SH SH SH SH SH SH SH SH
( PROPOSED )

( PROPOSED )

( PROPOSED )
6 3 R/H
2640

2640

2640
PANTRY 2 H/P &
UBO Selected S S Selected
1
Splashback Splashback
SH
UBO D/W

F. L. F. L. SH
7

Slide out bin


600 450 600 450 398 600 600 800 600 380 380 380 380 380 600

PANTRY FLOOR PLAN -UNIT " 1 " PANTRY ELEVATION " 1 " PANTRY ELEVATION " 2 " PANTRY ELEVATION " 3 "
8
1: 50 @ A3 1:50 1:50 1:50

9 NOTES: PROPOSED UNIT DEVELOPMENT © COPYRIGHT


THIS DRAWING REMAINS THE
REVISIONS: A
PROPERTY OF RENOCO HOMES. DATE DESCRIPTION DATE: 22/09/2020
cabinetry drawn indicative only, to be designed & confirmed cabinet makers and subcontractors shall check and verify all
by cabinet makers and/or owners. dimension and specifications, and all other relevant FOR : MS. XUELIN WANG DO NOT PRODUCE UNLAWFULLY. A 22/09/20 AS PER SECONDARY CONSENT DRAWN: M. Z / B. D
SCALES: AS SHOWN
documentation prior to the commencement of any works. AT : 27 DUNOON STRET, DO NOT SCALE DRAWINGS.

DONCASTER. VIC 3108


USE FIGURED DIMENSIONS ONLY.
KD 01
A B C D E F G H I J K L

1
UNIT " 2 "
C. L.
C. L.
SH SH
SH SH SH SH SH SH SH
2
SH

( PROPOSED )

( PROPOSED )
SH SH SH SH SH SH
SH R/H

2400

2400
2 H/P &
SH UBO REF S
KITCHEN SPACE
Selected
SH DR
1 Splashback D/W
SH SH SH SH
3
UBO DR

F. L. SH DR SH SH SH F. L.

665 441 441 600 441 441 25 900 25 Slide out bin
955 40 600 400 400 360 395 396 395 40

4
KITCHEN FLOOR PLAN -UNIT " 2 " KITCHEN ELEVATION " 1 " KITCHEN ELEVATION " 2 "
1: 50 @ A3 1:50 1:50

5
375 900 487 488 600 525 525 600

C. L. C. L. C. L.
SH
SH SH SH SH SH SH Selected SH SH SH
Splashback SH
( PROPOSED )

( PROPOSED )

( PROPOSED )
SH SH SH SH SH SH SH SH SH
6
3 R/H SH
2400

2400

2400
2 PANTRY H/P &
UBO S S SH
Selected
1
Splashback SH
SH
UBO D/W

F. L. F. L. SH
7

Slide out bin


525 600 525 600 600 600 800 600 600 525 525 600

PANTRY FLOOR PLAN -UNIT " 2 " PANTRY ELEVATION " 1 " PANTRY ELEVATION " 2 " PANTRY ELEVATION " 3 "
8
1: 50 @ A3 1:50 1:50 1:50

9 NOTES: PROPOSED UNIT DEVELOPMENT © COPYRIGHT


THIS DRAWING REMAINS THE
REVISIONS: A
PROPERTY OF RENOCO HOMES. DATE DESCRIPTION DATE: 22/09/2020
cabinetry drawn indicative only, to be designed & confirmed cabinet makers and subcontractors shall check and verify all
by cabinet makers and/or owners. dimension and specifications, and all other relevant FOR : MS. XUELIN WANG DO NOT PRODUCE UNLAWFULLY. A 22/09/20 AS PER SECONDARY CONSENT DRAWN: M. Z / B. D
SCALES: AS SHOWN
documentation prior to the commencement of any works. AT : 27 DUNOON STRET, DO NOT SCALE DRAWINGS.

DONCASTER. VIC 3108


USE FIGURED DIMENSIONS ONLY.
KD 02